Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 LARGE HEATERS KW. Installation Instructions & User Manual

Similar documents
Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 SMALL HEATERS KW. Installation Instructions & User Manual

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 MEDIUM HEATERS KW. Installation Instructions & User Manual

INSTALLATION GUIDE ULTRA-SAUNA HEATER. Proudly made in USA since 1964 LARGE HEATERS KW. Installation Instructions & User Manual

SCANDIA MANUFACTURING

ULTRA-SAUNA HEATER. Proudly made in USA since Gas Heaters - 40,000-80,000 BTU. Installation Instructions & User Manual

Sauna Craft CTT Heater Installation Manual

State problem and/or comments:

Sauna Craft Heater & Control Installation Manual

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

ULTRA SAUNA GAS INSTALL

INSTALLATION, OPERATION AND MAINTENANCE

Part No Revised November / Instruction Manual Model #8150 AND #8151

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

OWNER S MANUAL 1-2 PERSON SAUNA

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

Part No Revised: June TS1 TOASTER SYSTEM Instruction Manual Models # 5700 AND # 5700SF

OPERATION & INSTALLATION MANUAL

Cedarbrook Sauna + Steam Family owned and operated since 1971

IMPORTANT SAFETY INFORMATION

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

MODEL 560D DELUXE PIZZA OVEN

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

SC Installation, Operation & Application Guide

Instruction Manual. Part No Revised September 2004

R Series B & T2 Model

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Installation and Operations Manual

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

- User Brochure tekmarnet 4 Setpoint Control 161

Instruction Manual. Bucket Oil Pump

User s guide RUH series Economical unit heater Replacement component list included

USER S GUIDE SHU SERIES COMMERCIAL INDUSTRIAL UNIT HEATER REPLACEMENT COMPONENT LIST INCLUDED

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

Instruction Manual. Nacho Cheese Dispenser and Warmer

OPERATING INSTRUCTIONS

OWNER S MANUAL 1-2 PERSON SAUNA

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Instruction Manual. Portion Cup Cheese Warmer

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Instruction Manual and Warranty

TORRID MARINE YACHT QUALITY Since Owner s Manual

Instruction Manual Item No.: V~, 60Hz

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

Instruction Manual. Carmel Apple-Dip Warmer

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

IMPORTANT SAFETY INFORMATION:

Warmer Cabinet Instruction Manual Model # 5581, 5581EX. Part No

OPERATIONS MAINTENANCE MANUAL

INSTALLATION & OPERATING INSTRUCTIONS

Horizontal Bottle Cooler Installation and Operation Manual

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

MODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Dayton Electric Infrared Fireplace User Manual

InstructIon Manual KrEs EQuIPMEnt stands

- User Brochure Programmable Thermostat 510

OWNER S MANUAL Serenity Half Sauna

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

13500 BTU RV Air Conditioner Installation and Operating Instructions

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

XT Series Thermostats

Compact Equipment Warranty Policy

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Ceiling Mount Air Purification System

FW-RA-LED Remote Multiplex Annunciator Panels

Installation & Operation Manual

Wax Base Heater & Dispenser

Suntec. Infrared HomeHeating System. Model. Thermal Design

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

SC Installation, Operation & Application Guide

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

IMPORTANT. World-wide Patents. VIGIA is a trademark of Col-Ven S.A.

Expanded Backup Control Installation & Operator s Instruction Manual

IMPORTANT SAFETY INFORMATION:

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Instruction Manual. Cheese Warmer with Pump

5300, 5300CH, 5300EX, 5300FN

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

Instruction Manual. Astro Staging Cabinet

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

Transcription:

Heater Model Serial # Installation Guide ULTRA-SAUNA HEATER Proudly made in USA since 964 LARGE HEATERS.0-8.0 KW Installation Instructions & User Manual PO Box 636 Eagle Idaho USA. 8366 T: 877.467.86 F: 08.86.090 info@scandiamfg.com www.scandiamfg.com

BEFORE YOU START Heater and controls must be installed by a licensed electrician Heater must be installed according to local codes. Ensure all factory connections are tight. Wires may have come loose in shipping. Plastic must be removed from shell before operating heater. Sauna door must always open outward. Sauna door can never include a lock. YOUR HEATER SHOULD INCLUDE Controls Main Heater Unit Sauna Rocks Thermostat sensor wall cover (not included with T-model heaters) Installation Instructions Warning Sign HEATER SIZING Ultra Sauna Heaters Large (6 W x 8 D x 9 H) Model Watts Volts Phase Amps Max Room Size 40 000 40 50 40 sq ft (44 sq m) 40-3 000 40 3 9 40 sq ft (44 sq m) 08 000 08 57.7 40 sq ft (44 sq m) 08-3 000 08 3 33.3 40 sq ft (44 sq m) 540 5000 40 6.5 05 sq ft (63 sq m) 540-3 5000 40 3 36. 05 sq ft (63 sq m) 508 5000 08 7. 05 sq ft (63 sq m) 508-3 5000 08 3 4.7 05 sq ft (63 sq m) 840 8000 40 75 40 sq ft (73 sq m) 840-3 8000 40 3 43.3 40 sq ft (73 sq m) 808 8000 08 86.6 40 sq ft (73 sq m) 808-3 8000 08 3 50 40 sq ft (73 sq m) 8480-3 8000 480 3 40 sq ft (73 sq m) SAUNA ROOM VENTING GUIDELINES Sauna room should be vented according to manufacturer s specifications or Scandia sauna room specification found in the Scandia sauna installation instructions. Improper ventilation is dangerous for the sauna user s health. When the door is under cut, there is no other venting required in small sauna rooms. You should have between 3/4 to between the finished floor and the bottom of the door. If further venting is preferred or required, the inlet vent should be below the heater, or near the base of the heater. Outlet vent can be on the opposite wall of the heater under the top bench.

SAUNA HEATER GUARD RAIL PLACEMENT GUIDE Description KW 8KW A Width Of Heater Shell 6" B Wall to Face of Heater 8" C Side of Heater to Wall (Min.) 8" D Height of Heater Shell 9" E Wall to Inside of Guard (Min.) 6" F Lower to Upper Mounting 8" G F.F. to Bottom Mount 0 3/4" H Heater Center to Wall (Min.) " I F.F. to Bottom of Heater 0" J p of Heater to Ceiling (7ft.) 39" Minimum dimensions of heater guard must be 4 L x 6 d x 39 H p rail of guard must be below heater vent CONTROL PANEL MODELS AND SIZES A/B control: suitable A/B Control for heater Rough models -In Dimensions 7540, 7508, E control: suitable E/E4 for Control heater Rough models -In Dimensions 40, 08, 9040, 9008, 08-3 (standard or T-model heaters) Control Cover Plate 9 ¾ 8 ¼ 4" B L C H D I F A Ceiling (H-7ft) H C G J wall or guard rail 540, 508, 840, 808, 8480 (standard or T-model Control Cover Plate 3 ¼ ¼ 4" 4" 4 ¼ ¼ 5 ½ 0 0 45 5 45 5 30 30 ga Brushed Aluminum * NOTE: rough-in ½ extra on box dimensions I8 ga Galvanized Paint-loc Steel ga Brushed Aluminum * NOTE: rough-in ½ extra on box dimensions I8 ga Galvanized Paint-loc Steel CONTROL PANEL LOCATION All controls must be mounted on the outside of the sauna, NEVER inside the room. RESIDENTIAL INSTALLATION For convenience, place the control box at eye level by the door, approximately from the door opening and 5 from the floor(see fig. ). For conduit and wire size, type and quantities, see specific heater wiring diagram charts. COMMERCIAL INSTALLATION for 60-min timer, follow the residential installation recommendations. For 4-hour timer, you may place the control panel either in front of the sauna or in the mechanical or electrical room away from the sauna room. Please note that the thermostat capillary tube is only 4 ft long, therefore for controls placed away from the sauna, we recommend T-model heaters, where the thermostat is built in the heater itself. Door opens on the right " Sauna exterior wall 3 5"

STANDARD HEATER / CONTROL CONFIGURATION 60-min timer Line Feeds /Ground From Breaker Control panel on the outside of sauna room. Recessed mounted. Warning Signs Control Box Line feeds/ground from Control box to Heater Thermostat sensor bulb must be Thermostat mounted inside the sauna 0 from Sensor Bulb ceiling horizontal position. Use supplied bracket to hold it in place. Heater Wall mounted inside sauna room Note: All Ultra-Sauna heaters can be ordered as T-model from factory. T-model heaters have the thermostat built in the heater, eliminating the need to have the thermostat sensor in the wall. 0- View from outside of sauna Recommended grill vent below heater improves efficiency of heater. 4-hour timer Option # Controls near door Option # C ontrols in rem ote location Important: Control panel on the outside of sauna room. Recessed mounted. Line Feeds /Ground From Breaker Controls behind cover (4 hour tim er) Line feeds/ground from Control box to Heater Heater Wall mounted inside sauna room Line Feeds /Ground From Breaker Controls (4 hour tim er) Line feeds /ground from Control box to Heater For controls in remote locations, T-model heater is recommended, please ask your Scandia sales representative. 0- IMPORTANT NOTES: Recommended grill vent below heater improves efficiency of heater. - Heater must be installed by a licensed electrician. - Heater must be installed inside the sauna room and mounted one 0- foot from the floor. - Controls must be installed outside of the sauna room. - Thermostat capillary sensor bulb must be located inside the sauna room (horizontal position ) approx. 0 inches from ceiling. - All wiring must comply with Local and State ordinances : all wiring into the sauna room must be rated for at least 90 degrees Celsius (94 deg Farenhiet ). - Standard sauna ceiling height is 7 feet. - Consult all local codes before installation. - W arning signs must be installed at eye level on door and above heater. - Door must always swing outw ard. - Air intake vent must be installed below heater and an air exhaust vent should be installed. - Thermostat should be placed behind cover and out of control of guests /members. Setting should be no higher than 80 degrees farenheit (85 Celcius) 4

WIRING DIAGRAMS A3 control A3 Controls (60 minute timer) 9000 Watts to 000 Watts Heaters Three-phase only 40/08 Volts Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater 90-3 9000 40 / 08.7 / 5 3 80 sq ft 60 4 qty #8 ga 4 qty #8 ga - qty #4 0-3 000 40 / 08 9 / 33.4 3 0 sq ft 40 4 qty #8 ga 4 qty #8 ga - qty #4 Three Ph ase Power Feed 3 Grou nd Scandia electric heaters are UL listed Ground Term inal Timer High Limit Switch Element Element Element 3 3 4 5 6 High 3 Sauna Heater B3 control B3 A3 Controls (60 minute timer) 9000 Watts to 000 Watts Heaters Three-phase only 40/08 Volts Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater 90-3 9000 40 / 08.7 / 5 3 80 sq ft 40 60 4 qty #8 ga 4 qty #8 ga - qty #4 0-3 000 40 / 08 9 / 33.4 3 0 sq ft 50 40 4 qty #8 ga 4 qty #8 ga - qty #4 Three Phase 3 3 Power Feed Grou ndgrou nd C Scandia electric heaters Scandia electric heaters are UL listed are UL listed Ground Ground Terminal Terminal Timer High Limit it o actor ls C 3 3 Element Element High Limit High Limit Switch Switch High Limit Switch Element Element 3 3 Element Element 3 34 4 5 5 6 6 Control Box Sauna Sauna Heater Heater Heater 5

WIRING DIAGRAMS E control E Controls (60 minute timer) 000 8000 Watt 40/08 Volt single phase Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater) 000 40/08 50 / 57.7 0 sq ft 60 / 70 40 3 #6 / 08 3 #4 7 qty #0 qty #4 5000 40/08 6.5 / 7. 80 sq ft 70 / 90 40 3 #4 / 08 3 # 7 qty #0 qty #4 Series W atts Volts Amps E Control Phase for Mas Scandia/Vico Room Size Circuit Breaker KW,5KW Supply W ires and (incl 8KW ground) Heater W ires from control to heater 0 000 / 08 50 /57.7 08V 0 and 40V (Single 60/70 Phase (40V, Configuration) 3qty #6) 08V, 3qty #4) 7 qty #0 ga - qty #4 8000 40/08 75 / 86.6 40 sq ft 90 / 00 3 qty # 7 qty #0 qty #4 50 5000 40 / 08 6.5 / 7. 80 sq ft 70/90 (40V, 3qty #4) 08V, 3qty #) 7 qty #0 ga - qty #4 Single Phase 3 4 5 6 C o n ta c to r S c a n d ia e le c t r ic h e at e r s a re U L li s t ed Term inal T o H igh Sw itch C o n ta c to r T L T o H i g h T L E lem ents Fuse Assem blies 3 4 5 6 T o c o n ta c to r H igh E lement 6 3 E lement 5 Ele ment 3 4 C ontrol Box Sa una H eater E control Three Phase Powe r F eed 3 4 5 6 Con tactor E Controls (60 minute timer) 5000 8000 Watt 40/08 Volt 3 phase Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater 0 000 40 / 08 50 /57.7 0 sq ft 60/70 (40V, 3qty #6) 08V, 3qty #4) 7 qty #0 ga - qty #4 50 5000 40 / 08 6.5 / 7. 80 sq ft 70/90 (40V, 3qty #4) 08V, 3qty #) 7 qty #0 ga - qty #4 50-3 5000 40 / 08 36. / 4.7 3 80 sq ft 50 (40V, 4qty #8) 08V, 4qty #6) 7 qty #0 ga - qty #4 80 8000 40 / 08 75 / 86.6 40 sq ft 90/00 3qty # 7 qty #0 ga - qty #4 80-3 8000 40 / 08 43.4 / 50 3 40 sq ft 60 4qty #6 7 qty #0 ga - qty #4 C ontactor Ground Scandia electric heaters are U L listed Term inal T o conta cto r High L im it Switch Conta ctor Co ntactor T L High Limit T L Fu se Asse mblies 3 4 5 6 Ele ments contacto r High Limit Elemen t 6 3 Element 5 Elemen t 3 4 S auna H eater 6

WIRING DIAGRAMS E control E Controls (60 minute timer) 000 8000 Watt 40/08 Volt single phase T Models Watts Voltage Converting Amps Phase 60 Max minute Room Size timer Circuit to Breaker 4 hr programmable timer. L Supply Wires (Inc.Ground) Wires (Control to Heater) T 000 40/08 50 / 57.7 0 sq ft 60 / 70 40 3 #6 / 08 3 #4 7 qty #0 qty #4 5000 40/08 6.5 / 7. E Control for 80 Scandia/Vico sq ft 70 KW / 90,5KW 40 3 #4 and / 088KW 3 # Heater 7 qty #0 qty #4 8000 40/08 75 / 86.6 08V and 40V (Single Phase Configuration) 40 sq ft 90 / 00 3 qty # 7 qty #0 qty #4 Series W atts Volts Amps Phase Mas Room Size Circuit Breaker Supply W ires (incl ground) W ires from control to heater 0 000 40 / 08 50 /57.7 0 sq ft 60/70 (40V, 3qty #6) 08V, 3qty #4) 7 qty #0 ga - qty #4 50 5000 40 / 08 6.5 / 7. 80 sq ft 70/90 (40V, 3qty #4) 08V, 3qty #) 7 qty #0 ga - qty #4 Single Phase T L T o H i g h T o T L E lem ents 3 4 5 6 C o n ta c to r L Fuse Assem blies T C o n ta c to r 3 4 5 6 Tim er High T o c o n ta c to r C on tac to r H igh 3 E lement 6 S c a n d ia e le c t r ic h e at e r s a re U L li s t ed Term inal H igh Sw itch 3 E lement 5 Ele ment 3 4 T L C ontrol Box Sa una H eater E control E Controls (60 minute timer) 000 8000 Watt 40/08 Volt 3 phase T Models Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater) 000 40/08 9 / 33.4 3 0 sq ft 40 / 50 40 3 #6 / 08 3 #4 7 qty #0 qty #4 5000 40/08 36. / 4.7 3 80 sq ft 50 40 4 #8 / 08 4 #6 7 qty #0 qty #4 8000 40/08 43.4 / 50 3 40 sq ft 60 3 qty #6 7 qty #0 qty #4 T hree Pha se Powe r F eed 3 4 5 6 Con tactor C ontactor Ground Scandia electric heaters are U L listed Term inal T o conta cto r High L im it Switch Conta ctor Co ntactor T L High Limit T L E le m en Fu se Assemblies 3 4 5 6 n ts T o contacto r High Limit Elemen t 6 3 Element 5 Elemen t 3 4 Controls Sauna Heater 7

WIRING DIAGRAMS Converting 60 minute timer to 4 hr programmable timer. L T C on tac to r T L Tim er L T High 3 T L L T 8

SAUNA HEATER OPERATING INSTRUCTIONS Installation steps: A. Remove the protective cover off the heater shell. B. Hang the heater in place or as specified by manufacturer. C. Fill the heater rock tray with the sauna rocks. Note: This sauna heater should not be operated without the recommended quantity of rocks. D. ENSURE GOOD AIR CIRCULATION AROUND SENSOR BULB. Install the heater guard around rail around heater. After installation is completed, the heater should be turned on to maximum temperature for one hour to break any rocks having fault lines and to burn off the protective coating on the heater elements. Do not enter the sauna room during the initial start-up. The smell of smoke and cracking of rocks will not re-occur. Sauna Timer: Scandia Sauna controls come with standard 60 minute timer (wall mounted outside the sauna) and thermostat. For T models, the thermostat is located on the heater. turn on the heater, turn the timer knob up the desired time (up to the 60 min. mark). Leave knob at the setting and sauna will operate for one hour before shutting off automatically. Allow 30 minutes for room to heat up to an average sauna temperature. The thermostat is marked with numbers through 0. With being the coolest temperature and 0 the highest. Set the desired temperature. Note: Make sure the thermostat is on before setting up the time, otherwise the heater will not heat up. For 4-hour timer operation, see attached Operating Guidelines for 4-hour digital timer. Product Liability: The buyer acknowledges that the goods sold to them by Scandia Manufacturing can cause property damage and personal injury if not properly sized, handled or installed. The buyer further agrees to indemnify and hold harmless Scandia Manufacturing from any or all claims for damage, loss and/or liability arising out of improper handling, sizing and/or installation of goods. 9

Programming Instructions 4 digital hour timer Set or Change the Day and Time: clear entire memory, press key. Hold down the CLOCK key while pressing either the DAY, HOUR or MINUTES keys. Continue pressing until the desired day or number is shown. Then simply lift finger off of the CLOCK key to set. Set Program (ON/OFF times): Press TIMER key once to enter into program mode. Display will show ON - - - - Press DAY key to choose any of 5 different day combinations for the first ON time. Note: days of the week having the same program should be copied by selecting the desired combination of days. Press the HOUR key and then the MINUTE key to select the desired first ON time. Display Reset port to cancel all prior settings ON/AUTO/OFF Selection Key Indicator LED ON when connected to power source and contacts are closed. Press TIMER key once. Display will show OFF - - - -. Repeat previous step to select the desired OFF time. Repeat the entire sequence to complete up to eight ON/OFF times as desired. When programming is done, press the CLOCK key then the MANUAL key repeatedly until the indicator bar is above the word AUTO Review Program: Press TIMER key repeatedly. When done, press CLOCK key to return to the time of day. Cancel/Change Part of the Program: Press TIMER key repeatedly until the particular ON or OFF time appears, the repeatedly press the DAY key until the display show - - - - Set new ON and OFF time. ( See: Set Programs ) Override Automatic Operation: Press MAMUAL key to move indicator bar to the desired ON or OFF position. Note: Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO. 0

ULTRA SAUNA - WARRANTY Your Ultra Sauna heater has been engineered and built to the highest quality standards, and is backed by this warranty to assure your complete satisfaction: () SCANDIA Mfg warrants on the terms and conditions set forth below for ten years to the Original Owner only, at the Original Installation site only, this equipment to be free from defect in material and/or workmanship under normal use as specified in the equipment s instructions, FROM DATE OF PURCHASE and thereafter. () A TEN YEAR LIMITED WARRANTY applies only on the heater unit as manufactured by and at SCANDIA Mfg., - Manufacturing Plant and specifically excludes all components and/or parts which are accessories therein, namely: the gas valve; pilot generator: heating element; ; timer switch; thermostat; and, high limit, for which their respective manufacturers warranties apply. The TEN YEAR LIMITED WARRANTY does not apply for units that have been installed in commercial locations such as clubs, condominiums, apartments, spas or military facilities. In commercial locations, Scandia will provide a one-year warranty on the unit. (3) During the first year SCANDIA will, at its option, repair or exchange at the Factory all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship, without cost to customer except for freight and/or crating charges. (4) For the period commencing with the second year and for the ten year warranty of the original purchaser only, at the original installation only, SCANDIA will, at its option, repair or exchange at the Factory, all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship except the following parts which are excluded from this warranty: the gas valve; pilot generator: heating element; ; timer switch; thermostat; and, high limit. (5) This warranty in its entirety becomes null and void if unit is rented or to be used for rental purposes or installed in any mobile or fixed prefab rental room. If original purchaser is a corporation then, the president of said corporation, shall be construed as registered Original Owner for all purposes herein, otherwise this warranty in its entirety becomes null and void. (6) This warranty in its entirety becomes null and void if unit has been installed by an unlicensed party by and/or in the city and/or county where installation is made. Furthermore if unit is disassembled and/or tampered with in any way possible by any one (individual and/or company) then this warranty in its entirety becomes null and void. SCANDIA reserves the right to substitute new equipment or parts on any orders for replacement hereunder, but shall not be obligated to do so. This warranty is solely for the benefit of the original purchaser and no one else, and only if the installation and operating instructions applicable to the model purchased are followed. These instructions are furnished with the unit and also are available by writing SCANDIA s warehouse. These instructions are incorporated herein by reference as if set forth in full. This warranty does not cover damages which appear to SCANDIA to have resulted from neglect, alteration, abuse, misuse, accident, flood, fore or other act of force majeure, or other than normal use. This warranty is expressly in lieu of other warranties, or liabilities, express or implied, by the Company or its representatives, and in lieu of all other obligations and liabilities for damage to persons or property caused in any manner by the heater or its component parts. More specifically, by not by way of limitation, SCANDIA assumes no liability for damages which may occur as a result of neglect or intentional misuse of the unit, and the purchaser or user of the unit agrees to assume all liability for the consequences of its use or misuse by such purchaser or user, and his, its or their respective employees and agents or other third person. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO REPRESENTATION OR WARRANTIES ARE MADE, EXPRESSED OR IMPLIED, OTHER THAN THOSE EXPRESSLY HEREIN SET FORTH TO THE ORIGINAL PURCHASER ONLY. obtain the benefits of this Warranty, the inoperative parts and/or complete heater must be sent to Scandia, all shipping and crating charges prepaid. And all repaired or replaced parts or heaters will be returned freight collect. This warranty is effective only when the attached Factory Registration Stub is completed and returned to the manufacturer. Please contact Scandia for return authorization at 877-467-86 or via e-mail info@scandiamfg.com Warranty stub must be mailed or completed online within thirty DAYS TO REGISTER AND VALIDATE THIS WAR- RANTY, WHICH BECOMES VALID ONLY IF THE HEATER HAS BEEN PURCHASED DIRECTLY FROM SCANDIA MFG., AND/OR AUTHORIZED DEALERS IN U.S.A., its territories or possessions. TO VALIDATE WARRANTY VISIT WWW.SCANDIAMFG.COM/PRODUCT_REGISTRATION.HTML AND REGIS- TER YOUR PRODUCT. ALL PRODUCTS MUST BE REGISTERED PRIOR TO ANY WARRANTY CLAIMS.