Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 MEDIUM HEATERS KW. Installation Instructions & User Manual

Similar documents
Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 SMALL HEATERS KW. Installation Instructions & User Manual

Installation Guide ULTRA-SAUNA HEATER. Proudly made in USA since 1964 LARGE HEATERS KW. Installation Instructions & User Manual

INSTALLATION GUIDE ULTRA-SAUNA HEATER. Proudly made in USA since 1964 LARGE HEATERS KW. Installation Instructions & User Manual

SCANDIA MANUFACTURING

ULTRA-SAUNA HEATER. Proudly made in USA since Gas Heaters - 40,000-80,000 BTU. Installation Instructions & User Manual

Sauna Craft CTT Heater Installation Manual

State problem and/or comments:

Sauna Craft Heater & Control Installation Manual

Part No Revised January 30, 2007 SAFETY PRECAUTIONS

ULTRA SAUNA GAS INSTALL

INSTALLATION, OPERATION AND MAINTENANCE

FOR EASY, FAST INSTALLATION AND FOR RESULTS

Part No Revised December 2002 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5510, 5511 AND 5512

Part No Revised November 2004 DESIGNER SERIES NACHO CABINETS Instruction Manual Model #5513

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

OPERATION & INSTALLATION MANUAL

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

IMPORTANT SAFETY INFORMATION

Part No Revised: June TS1 TOASTER SYSTEM Instruction Manual Models # 5700 AND # 5700SF

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

OWNER S MANUAL 1-2 PERSON SAUNA

Instruction Manual. Dogeroo, Super Dogeroo, and Mini Dogeroo

MODEL 560D DELUXE PIZZA OVEN

FW-RA-LED Remote Multiplex Annunciator Panels

Part No Revised November / Instruction Manual Model #8150 AND #8151

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Henny Penny Island Warmer Model HMI-103 Model HMI-105 TECHNICAL MANUAL

SPA HEATER INSTALLATION, OPERATION AND MAINTENANCE

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

USER S GUIDE SHU SERIES COMMERCIAL INDUSTRIAL UNIT HEATER REPLACEMENT COMPONENT LIST INCLUDED

Cedarbrook Sauna + Steam Family owned and operated since 1971

- User Brochure tekmarnet 4 Setpoint Control 161

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

OPERATING INSTRUCTIONS

Instruction Manual. Nacho Cheese Dispenser and Warmer

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Instruction Manual. Portion Cup Cheese Warmer

OWNER S MANUAL 1-2 PERSON SAUNA

R Series B & T2 Model

MODEL 620 ELECTRICAL DATA: FEATURES: DIMENSIONS: SHIPPING INFORMATION: AVAILABLE ACCESSORIES: CONVECTION OVEN 1/4 SIZE PAN

Instruction Manual. Part No Revised September 2004

Installation and Operations Manual

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.

WCPT-3 and WCPT-4. Effective Date: 2017 IMPORTANT INFORMATION READ BEFORE USE. Drop-in Display Cases

User s guide RUH series Economical unit heater Replacement component list included

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Installation & Operation Manual

Instruction Manual. Bucket Oil Pump

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

OPERATIONS MAINTENANCE MANUAL

SC Installation, Operation & Application Guide

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

Condiment Warmer. Instruction Manual Models #2252EX & #2253EX. Cincinnati, OH USA. Model #2252EX. Model #2253EX

Wax Base Heater & Dispenser

Warmer Cabinet Instruction Manual Model # 5581, 5581EX. Part No

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

Horizontal Bottle Cooler Installation and Operation Manual

XT Series Thermostats

OWNER S MANUAL Serenity Half Sauna

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

MODEL HBX-1 P/N 3G59332

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

MP BB. ElEcTrIc FIrEplAcE HEATEr. INSTrUcTION MANUAl ATTENTION:

READ AND SAVE THESE INSTRUCTIONS

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

TORRID MARINE YACHT QUALITY Since Owner s Manual

Suntec. Infrared HomeHeating System. Model. Thermal Design

IMPORTANT SAFETY INFORMATION:

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

Electric Space Heater

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Instruction Manual. Carmel Apple-Dip Warmer

INSTALLATION & OPERATING INSTRUCTIONS

CT2 Retro Box Installation Instruction Manual

Cheese Display Case. Instruction Manual Model #5580BV2 and Model #5580BV3 Model #5582 and Model #5583. Cincinnati, OH USA.

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Expanded Backup Control Installation & Operator s Instruction Manual

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Instruction Manual. Cheese Warmer with Pump

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Part No Revised: October 2004 BUN WARMER. Instruction Manual. Models:8018,8019,8117,8219,8170

Compact Equipment Warranty Policy

Instruction Manual and Warranty

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

Instruction Manual. Cheddar Easy All-In-One Cheese Corn Shop

User Guide AutoSealer 1001

OPERATING INSTRUCTIONS

CF SERIES CF100 CF200 CF300

CENTRIFUGAL FANS user's manual. model VENTS VK.

Installation & Operation Manual

FOOD WARMING/MERCHANDISING CABINET MODEL

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003

Transcription:

Heater Model Serial # Installation Guide ULTRA-SAUNA HEATER Proudly made in USA since 1964 MEDIUM HEATERS 6.0-9.0 KW Installation Instructions & User Manual PO Box 636 Eagle Idaho USA. 83616 T: 877.467.2862 F: 208.286.0290 info@scandiamfg.com www.scandiamfg.com 1

BEFORE YOU START Heater and controls must be installed by a licensed electrician Heater must be installed according to local codes. Ensure all factory connections are tight. Wires may have come loose in shipping. Plastic must be removed from shell before operating heater. Sauna door must always open outward. Sauna door can never include a lock. YOUR HEATER SHOULD INCLUDE Controls Main Heater Unit Sauna Rocks Thermostat sensor wall cover (not included with T-model heaters) Installation Instructions Warning Sign HEATER SIZING Ultra Sauna Heaters Medium (16 W x 14 D x 28-3/4 H) Model Watts Volts Phase Amps Max Room Size 60240 6000 240 5 42 sq ft (12.8 sq m) 60208 6000 208 8.9 42 sq ft (12.8 sq m) 75240 7500 240 1 31.3 64 sq ft (19.5 sq m) 75208 7500 208 1 36.1 64 sq ft (19.5 sq m) 90240 9000 240 1 37.5 88 sq ft (27 sq m) 90240-3 9000 240 3 21.7 88 sq ft (27 sq m) 90208 9000 208 1 43.3 88 sq ft (27 sq m) 90208-3 9000 208 3 25 88 sq ft (27 sq m) SAUNA ROOM VENTING GUIDELINES Sauna room should be vented according to manufacturer s specifications or Scandia sauna room specification found in the Scandia sauna installation instructions. Improper ventilation is dangerous for the sauna user s health. When the door is under cut, there is no other venting required in small sauna rooms. You should have between 3/4 to 1 between the finished floor and the bottom of the door. If further venting is preferred or required, the inlet vent should be below the heater, or near the base of the heater. Outlet vent can be on the opposite wall of the heater under the top bench. 2

SAUNA HEATER GUARD RAIL PLACEMENT GUIDE CHASSIS MEDIUM Description 6.0KW 9.0KW A Width Of Heater Shell 16" B Wall to Face of Heater 14" C Side of Heater to Wall (Min.) 5" D Height of Heater Shell 28 3/4" E Wall to Inside of Guard (Min.) 19" F Lower to Upper Mounting 22 1/2" G F.F. to Bottom Mount 14" H Heater Center to Wall (Min.) 13" I F.F. to Bottom of Heater 10" J p of Heater to Ceiling (7ft.) 40" Minimum dimensions of heater guard must be 26 L x 19 d x 33-3/4 H p rail of guard must be below heater vent CONTROL PANEL MODELS AND SIZES F control: suitable for heater model 60240, and heaters A/B control: suitable A/B Control for heater Rough models -In Dimensions 60208, 75240, with remote contactors. F Control Rough-In Dimensions 75208, 90240, 90208 (standard or T-model heaters) Control Cover Plate 6" Control Box 4" 3 " B E L C H D Control Cover Plate 9 ¾ I F A Ceiling (H-7ft) H C G J wall or guard rail Control Box 8 ¼ 4" 10 1/2" 45 0 15 8" 14 ¼ 0 45 30 15 12 ¼ 30 22ga Brushed Aluminum I8 ga Galvanized Paint-loc Steel 22 ga Brushed Aluminum * NOTE: rough-in ½ extra on box dimensions I8 ga Galvanized Paint-loc Steel CONTROL PANEL LOCATION All controls must be mounted on the outside of the sauna, NEVER inside the room. RESIDENTIAL INSTALLATION For convenience, place the control box at eye level by the door, approximately 12 from the door opening and 52 from the floor (see fig. 1). For conduit and wire size, type and quantities, see specific heater wiring diagram charts. COMMERCIAL INSTALLATION for 60-min timer, follow the residential installation recommendations. For 24-hour timer, you may place the control panel either in front of the sauna or in the mechanical or electrical room away from the sauna room. Please note that the thermostat capillary tube is only 4 ft long, therefore for controls placed away from the sauna, we recommend T-model heaters, where the thermostat is built in the heater itself. Door opens on the right 12" Sauna exterior wall 3 52"

STANDARD HEATER / CONTROL CONFIGURATION 60-min timer Line Feeds /Ground From Breaker Control panel on the outside of sauna room. Recessed mounted. Warning Signs Control Box Line feeds/ground from Control box to Heater Thermostat sensor bulb must be Thermostat mounted inside the sauna 10 from Sensor Bulb ceiling horizontal position. Use supplied bracket to hold it in place. Heater Wall mounted inside sauna room Note: All Ultra-Sauna heaters can be ordered as T-model from factory. T-model heaters have the thermostat built in the heater, eliminating the need to have the thermostat sensor in the wall. 10-12 View from outside of sauna Recommended grill vent below heater improves efficiency of heater. 24-hour timer Control panel on the outside of sauna room. Recessed Option #1 C ontrols near door Line Feeds /Ground From Breaker Controls behind cover (24 hour tim er) Line feeds/ground from C ontrol box to H eater Heater Wall mounted inside sauna room Option #2 C ontrols in rem ote location Line Feeds /Ground From Breaker Controls (24 hour tim er) Line feeds /ground from C ontrol box to H eater Important: For controls in remote locations, T-model heater is recommended, please ask your Scandia sales representative. 10-12 IMPORTANT NOTES: Recommended grill vent below heater improves efficiency of heater. - H eater must be installed by a licensed electrician. - H eater must be installed inside the sauna room and mounted one 10-12 foot from the floor. - C ontrols must be installed outside of the sauna room. - Thermostat capillary sensor bulb must be located inside the sauna room (horizontal position ) approx. 10 inches from ceiling. - All w iring must comply w ith Local and State ordinances : all w iring into the sauna room must be rated for at least 90 degrees C elsius (194 deg Farenhiet ). - Standard sauna ceiling height is 7 feet. - C onsult all local codes before installation. - W arning signs must be installed at eye level on door and above heater. - D oor must alw ays sw ing outw ard. - Air intake vent must be installed below heater and an air exhaust vent should be installed. - Thermostat should be placed behind cover and out of control of guests /members. Setting should be no higher than 180 degrees farenheit (85 C elcius) 4

WIRING DIAGRAMS F control H control H Controls (for T-Model Heaters) 3000 W atts to 6000 W atts Heaters Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Wires from control to heater B Controls (60 minute timer) 6000 Watts 240 Volt Heater T Model 30 3000 240 / 208 12.5 / 14.4 0 sq ft 20 3 qty #14 ga Series H Controls (for T-Model Heaters) 3000 W atts to 6000 W atts Heaters 45 Watts 4500 Voltage 240 / 208 Amps 18.8 / 21.7 Phase 1 Max 30 Room sq ftsize Circuit 30 Breaker Wires 3 qty (Control #10 to gaheater) Single-phase H Controls (thermostat only 240/208 on heater) Volts 60 6000 240 / 208 25 / 28.9 1 1 42 sq ft 30/40 3 qty 3 qty #8#10 2 ga qty #14 H igh -Limit Line Timer to High -Limit on Base of H eater H igh Limit H eater Element s Heater Thermostat H eater Elem ent Line T2 to heater element s 240V Single phase F Controls (60 minute timer) 3000 Watts to 6000 Watts Heaters Single-phase only 240/208 Volts F Controls (60 minute timer) 6000 Watts 240 Volt Heater Series Series Watts Volts Amps Phase Mas Mas Room Room Size Size Circuit Circuit Breaker Breaker Wires Wires from from control control to heater to heater 30 30 3000 240 / 208 12.5 / 14.4 0 20 sq sq ft ft 20 20 3 qty 3 qty #14 #14 ga ga Series Watts Voltage Amps Phase Max Room Size Circuit Breaker Wires (Control to Heater) 45 45 4500 240 / 208 18.8 / 21.7 1 30 30 sq sq ft ft 30 30 3 qty 3 qty #10 #10 ga ga 60 60 6000 240 / 208 25 25 / 28.9 F Controls (60 minute 42 sq timer 1 42 sq ft ft ft version) 240V Single Phase 30/40 30/40 30 3 qty 3 qty #10 #8#10 ga 2 ga qty #14 Heater Controls T1 T2 Timer Controls L2 L1 Power Feed W ires Pow er to L1 and L 2 Thermostat High -Limit Line Timer to High-Limit on Base of Heat er High Limit Heater Elem ents T1 L1 Power Feed Wires Pow er to L1 and L2 H eater Element Line T2 t o heater elem ents T2 Timer L2 5

WIRING DIAGRAMS A2 control B2 control B Controls (60 minute timer) 6000 Watts 208 Volt Heater 7000 Watts to 9000 Watts 240/208 Volt single phase T Models Series Watts Voltage B Amps Controls Phase (60 minute Max timer) Room Size 7500 Circuit W atts Breaker to 9000 Supply WWires atts (Inc.Ground) Heate rs Wires (Control to Heater) Single-phase only 240/208 Volts. For T-Model Heaters 60 6000 208 28.9 1 42 sq ft 40 3 qty #8 3 qty #8 2 qty #14 Se ries W atts Vo lts Am ps P ha se Mas Ro om S ize Circuit B reake r W ires from contro l to h eater 75 75 7500 240/208 750 0 240 31.3 / 208 / 36.1 31.3 1 / 36.1 561sq ft 56 sq 40 ft 40 3 qty #8 3 qty 3 #8 qty ga #8-2 qty 2 qty #14 #14 90 900 0 240 / 208 37.5 / 43.3 1 80 sq ft 50 3 qty #8 ga - 2 qty #14 90 9000 240/208 37.5 / 43.3 1 80 sq ft 50 3 qty #8 3 qty #8 2 qty #14 SIngle Phase Powe r Feed Tim er A Controls (60 minute timer) 6000 Watts 208 Volt Heater 7000 Watts to 9000 Watts 240/208 Volt single phase Series Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater) 60 6000 208 28.9 1 42 sq ft 40 3 qty #8 3 qty #8 2 qty #14 75 7500 240/208 31.3 A / Controls 36.1 (60 1 minute 56 timer) sq ft 7500 40 Watts to 90003 Wqty atts #8 Heaters 3 qty #8 2 qty #14 90 9000 240/208 37.5 / 43.3 1 Single-phase 80 sq ft only 240/208 50 Volts 3 qty #8 3 qty #8 2 qty #14 SI ngle P hase Power Feed con ta ctor co ils Con tacto r Conta ctor Control Box A Controls (60 minute timer) 7500 Watts to 9000 W atts Heaters Single-phase only 240/208 Volts contactor Ground Ground Elem ent 1 1 Scandia elec tric heaters are U L listed G round Term inal 2 Scandia electric heaters are UL listed Grou nd Terminal High Limit Switch Elem ent 2 3 4 Sauna Heater ** 9kw heaters will have 3 elements ** Tim er co ntacto r Contactor con tactor H ig h Lim it Switch Conta ct or Element 1 1 2 Element 2 3 4 ** 9kw heaters will have 3 elements ** Con trol Box S auna Heate r 6

WIRING DIAGRAMS B3 control B3 Controls A3 Controls (60 minute (60 minute timer) timer) 9000 9000 Watts Watts 240/208 to 12000 Volt Watts 3 phase Heaters Three-phase T Model only 240/208 Volts Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater Series Watts Voltage Amps Phase Max Room Size Circuit Breaker Supply Wires (Inc.Ground) Wires (Control to Heater) 90-3 9000 240 / 208 21.7 / 25 3 80 sq ft 40 60 4 qty #8 ga 4 qty #8 ga - 2 qty #14 120-3 12000 240 / 208 29 / 33.4 3 120 sq ft 50 40 4 qty #8 ga 4 qty #8 ga - 2 qty #14 90 9000 240/208 21.7/25 3 80 sq ft 40 4 qty #10 4 qty #10 2 #14 Three Phase 1 3 2 3 Power Feed Grou ndgrou nd Contactor C Contactor Scandia electric heaters Scandia electric heaters are UL listed are UL listed Ground Ground Terminal Terminal contactor Timer High Limit it o actor ls Contactor C Contactor 1 3 2 3 contactor contactor Element Element 1 1 1 High Limit High Limit Switch Switch 12 High Limit Switch Element Element 3 3 Element Element 2 2 3 34 4 5 5 6 6 2 Control Control Box Box Sauna Sauna Heater Heater Heater A3 control A3 Controls (60 minute timer) 9000 Watts to 12000 Watts Heaters Three-phase only 240/208 Volts Series Watts Volts Amps Phase Mas Room Size Circuit Breaker Supply Wires (incl ground) Wires from control to heater 90-3 9000 240 / 208 21.7 / 25 3 80 sq ft 40 60 4 qty #8 ga 4 qty #8 ga - 2 qty #14 120-3 12000 240 / 208 29 / 33.4 3 120 sq ft 40 4 qty #8 ga 4 qty #8 ga - 2 qty #14 Three Ph ase Power Feed 3 Contactor Grou nd Scandia electric heaters are UL listed Ground Term inal contactor Timer contactor High Limit Switch Contactor Element 1 1 2 Element 2 Element 3 3 4 5 6 High Lim it 3 Control Box Sauna Heater 7

WIRING DIAGRAMS Converting 60 minute timer to 24 hr programmable timer. L 1 T 1 C on tac to r T 2 L 2 Tim er contactor co ils Contactor contactor co ils L T High Lim it 3 Control Box T1 L1 L2 T2 8

SAUNA HEATER OPERATING INSTRUCTIONS Installation steps: A. Remove the protective cover off the heater shell. B. Hang the heater in place or as specified by manufacturer. C. Fill the heater rock tray with the sauna rocks. Note: This sauna heater should not be operated without the recommended quantity of rocks. D. ENSURE GOOD AIR CIRCULATION AROUND SENSOR BULB. Install the heater guard around rail around heater. After installation is completed, the heater should be turned on to maximum temperature for one hour to break any rocks having fault lines and to burn off the protective coating on the heater elements. Do not enter the sauna room during the initial start-up. The smell of smoke and cracking of rocks will not re-occur. Sauna Timer: Scandia Sauna controls come with standard 60 minute timer (wall mounted outside the sauna) and thermostat. For T models, the thermostat is located on the heater. turn on the heater, turn the timer knob up the desired time (up to the 60 min. mark). Leave knob at the setting and sauna will operate for one hour before shutting off automatically. Allow 30 minutes for room to heat up to an average sauna temperature. The thermostat is marked with numbers 1 through 10. With 1 being the coolest temperature and 10 the highest. Set the desired temperature. Note: Make sure the thermostat is on before setting up the time, otherwise the heater will not heat up. For 24-hour timer operation, see attached Operating Guidelines for 24-hour digital timer. Product Liability: The buyer acknowledges that the goods sold to them by Scandia Manufacturing can cause property damage and personal injury if not properly sized, handled or installed. The buyer further agrees to indemnify and hold harmless Scandia Manufacturing from any or all claims for damage, loss and/or liability arising out of improper handling, sizing and/or installation of goods. 9

Programming Instructions 24 digital hour timer Set or Change the Day and Time: clear entire memory, press key. Hold down the CLOCK key while pressing either the DAY, HOUR or MINUTES keys. Continue pressing until the desired day or number is shown. Then simply lift finger off of the CLOCK key to set. Set Program (ON/OFF times): Press TIMER key once to enter into program mode. Display will show 1 ON - - - - Press DAY key to choose any of 15 different day combinations for the first ON time. Note: days of the week having the same program should be copied by selecting the desired combination of days. Press the HOUR key and then the MINUTE key to select the desired first ON time. Display Reset port to cancel all prior settings ON/AUTO/OFF Selection Key Indicator LED ON when connected to power source and contacts are closed. Press TIMER key once. Display will show 1 OFF - - - -. Repeat previous step to select the desired OFF time. Repeat the entire sequence to complete up to eight ON/OFF times as desired. When programming is done, press the CLOCK key then the MANUAL key repeatedly until the indicator bar is above the word AUTO Review Program: Press TIMER key repeatedly. When done, press CLOCK key to return to the time of day. Cancel/Change Part of the Program: Press TIMER key repeatedly until the particular ON or OFF time appears, the repeatedly press the DAY key until the display show - - - - Set new ON and OFF time. ( See: Set Programs ) Override Automatic Operation: Press MAMUAL key to move indicator bar to the desired ON or OFF position. Note: Timer will not resume automatic operation until indicator bar is repositioned above the word AUTO. 10

ULTRA SAUNA - WARRANTY Your Ultra Sauna heater has been engineered and built to the highest quality standards, and is backed by this warranty to assure your complete satisfaction: (1) SCANDIA Mfg warrants on the terms and conditions set forth below for ten years to the Original Owner only, at the Original Installation site only, this equipment to be free from defect in material and/or workmanship under normal use as specified in the equipment s instructions, FROM DATE OF PURCHASE and thereafter. (2) A TEN YEAR LIMITED WARRANTY applies only on the heater unit as manufactured by and at SCANDIA Mfg., - Manufacturing Plant and specifically excludes all components and/or parts which are accessories therein, namely: the gas valve; pilot generator: heating element; contactor; timer switch; thermostat; and, high limit, for which their respective manufacturers warranties apply. The TEN YEAR LIMITED WARRANTY does not apply for units that have been installed in commercial locations such as clubs, condominiums, apartments, spas or military facilities. In commercial locations, Scandia will provide a one-year warranty on the unit. (3) During the first year SCANDIA will, at its option, repair or exchange at the Factory all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship, without cost to customer except for freight and/or crating charges. (4) For the period commencing with the second year and for the ten year warranty of the original purchaser only, at the original installation only, SCANDIA will, at its option, repair or exchange at the Factory, all parts which it finds have become inoperative during said warranty period due to a defect in material or workmanship except the following parts which are excluded from this warranty: the gas valve; pilot generator: heating element; contactor; timer switch; thermostat; and, high limit. (5) This warranty in its entirety becomes null and void if unit is rented or to be used for rental purposes or installed in any mobile or fixed prefab rental room. If original purchaser is a corporation then, the president of said corporation, shall be construed as registered Original Owner for all purposes herein, otherwise this warranty in its entirety becomes null and void. (6) This warranty in its entirety becomes null and void if unit has been installed by an unlicensed party by and/or in the city and/or county where installation is made. Furthermore if unit is disassembled and/or tampered with in any way possible by any one (individual and/or company) then this warranty in its entirety becomes null and void. SCANDIA reserves the right to substitute new equipment or parts on any orders for replacement hereunder, but shall not be obligated to do so. This warranty is solely for the benefit of the original purchaser and no one else, and only if the installation and operating instructions applicable to the model purchased are followed. These instructions are furnished with the unit and also are available by writing SCANDIA s warehouse. These instructions are incorporated herein by reference as if set forth in full. This warranty does not cover damages which appear to SCANDIA to have resulted from neglect, alteration, abuse, misuse, accident, flood, fore or other act of force majeure, or other than normal use. This warranty is expressly in lieu of other warranties, or liabilities, express or implied, by the Company or its representatives, and in lieu of all other obligations and liabilities for damage to persons or property caused in any manner by the heater or its component parts. More specifically, by not by way of limitation, SCANDIA assumes no liability for damages which may occur as a result of neglect or intentional misuse of the unit, and the purchaser or user of the unit agrees to assume all liability for the consequences of its use or misuse by such purchaser or user, and his, its or their respective employees and agents or other third person. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO REPRESENTATION OR WARRANTIES ARE MADE, EXPRESSED OR IMPLIED, OTHER THAN THOSE EXPRESSLY HEREIN SET FORTH TO THE ORIGINAL PURCHASER ONLY. obtain the benefits of this Warranty, the inoperative parts and/or complete heater must be sent to Scandia, all shipping and crating charges prepaid. And all repaired or replaced parts or heaters will be returned freight collect. This warranty is effective only when the attached Factory Registration Stub is completed and returned to the manufacturer. Please contact Scandia for return authorization at 877-467-2862 or via e-mail info@scandiamfg.com Warranty stub must be mailed or completed online within thirty DAYS TO REGISTER AND VALIDATE THIS WAR- RANTY, WHICH BECOMES VALID ONLY IF THE HEATER HAS BEEN PURCHASED DIRECTLY FROM SCANDIA MFG., AND/OR AUTHORIZED DEALERS IN U.S.A., its territories or possessions. TO VALIDATE WARRANTY VISIT WWW.SCANDIAMFG.COM/PRODUCT_REGISTRATION.HTML AND REGIS- TER YOUR PRODUCT. ALL PRODUCTS MUST BE REGISTERED PRIOR TO ANY WARRANTY CLAIMS. 11