Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Similar documents
Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

CHAPTER 1 INTRODUCTION

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

η second law = Second law efficiency

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

A Comparison Between Refrigerants Used In Air Conditioning

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Review of Current Automobile Refrigeration System on Basis of Refrigerants Used & Their Impact on Global Warming Potential.

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

International Journal of Advance Engineering and Research Development

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Evaluation of Vapour Compression Refrigeration System Using Different Refrigerants

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Thermodynamic study of R134a in Vapour Compression Refrigeration System in Summer Climate

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

Chapter 2. Alternatives to HCFCs and their Characteristics

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Refrigerants Retrofit as Alternative for R12 and R134a in Household Refrigerators

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Thermodynamics II Chapter 5 Refrigeration

Chapter 11 REFRIGERATION CYCLES

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Chapter 11 REFRIGERATION CYCLES

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

R134a Refrigerant in Vapour Compression Cycle: A Review Paper

ADVANCES in NATURAL and APPLIED SCIENCES

Study of R161 Refrigerant for Residential Airconditioning

Chapter 10. Refrigeration and Heat Pump Systems

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

CHAPTER 1 INTRODUCTION

HFCs or the Old Refrigerants - what is the best Choice?

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Natural refrigerants - naturally efficient

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

A RECENT REVIEW OF REFRIGERANT R-1234YF AND R-1234ZE (E)

Evaluation of HCFC Alternative Refrigerants

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Comparative Exergy Analysis of Vapor Compression Refrigeration System Using Alternative Refrigerants

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

11/22/2014. (c) DR.A.M.SURENDRA KUMAR

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

JJMIE Jordan Journal of Mechanical and Industrial Engineering

*Corresponding author;

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

ENERGY PERFORMANCE ASSESSMENT OF R134A/LPG BLEND AS REPLACEMENT OF R134A IN VAPOR COMPRESSION REFRIGERATION SYSTEM

R-404A Alternative with Low Compressor Discharge Temperature

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Performance improvement of vapour compression refrigeration systems

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

Oyelami S., Bolaji B. O.

Use of R1234yf, R744 (CO 2 ) and R134a in automotive air conditioning

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

Department of MCE, Islamic University of Technology 2. Abstract

Theoretical analysis of low GWP mixture R600a/ R1234ze as a possible alternative to R600a in domestic refrigerators

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

EXPERIMENTAL INVESTIGATION OF A REFRIGERATOR BY USING ALTERNATIVE ECO FRIENDLY REFRIGERANTS (R600A & HC MIXTURE)

A Review on selecting an Eco-friendly Refrigerant alternate to R134a in Domestic Refrigerators

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Transcription:

Available online at www.ijapie.org International Journal of Advanced Production and Industrial Engineering IJAPIE-SI-IDCM 606 (2017) 24 30 Special Issue on INNOVATIVE DESIGN & COMPUTATIONAL MODELLING Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System Komal 1, Abhay Thapliyal 2, Akhilesh Arora 3 1 Department of Mechanical Engineering, Delhi Technological University, New Delhi-110042, India. Email: moriarty311292@gmail.com Abstract : The automotive industry is currently using R134a as the refrigerant. It was introduced as a replacement of R12 as it had no chlorine content, and so did not harm the ozone layer. However, it has a very high global warming potential. Efforts to reduce green house gas emissions, guided by Kyoto Protocol have led to search for an alternative refrigerant. The various possible alternatives that have been researched so far have been discussed here and keeping in mind the requirements of environmental concern and performance of automobile AC system R1234yf and R436a were selected for our analysis.the thermodynamic system level performance was tested using EES and REFPROP software. The results indicated that R1234yf and R436a can match the performance of R134a by additional superheating and subcooling. Further, the vehicle level testing of R1234yf was done at Subros in their wind tunnel lab. Vehicle Cool down test was conducted and the results showed that with R1234yf as refrigerant the minimum temperature that could be reached was about 2C higher than with R134a. But the suction pressure was higher and discharge pressure was lower, which was beneficial. Thus, it was concluded that considering the advantages as well as current implementation issues both are feasible replacement options. Keywords: R134a, R436A, R1234yf, Automotive Air Conditioning System I. INTRODUCTION The automobile air conditioning system works on vapour compression refrigeration cycle. Currently tetraflouroethane, R134a is being used as the refrigerant. R134a replaced R12 in late 1995 due to concerns over R12's effect on the ozone layer. But because of its high global warming potential, 1, 1, 1, 2-tetrafluoroethane has to be replaced soon, starting with cars in 2011 and phasing out completely by 2017. Tetrafluoroethane (R134a) is a hydrofluorocarbon or HFC compound, comprising of two atoms of carbon, two atoms of hydrogen and four atoms of fluorine. Its chemical formula is CF3CH2F. It is used primarily as a refrigerant for domestic refrigeration and automobile air conditioner. R134a has no chlorine content and hence zero ozone depletion potential (ODP=0). Refrigerant properties Irrespective of the size and efficiency of the individual parts in the vapour compression circuit, a good refrigerant is one, ensuring the highest overall effectiveness of the system. Required Properties of Ideal Refrigerant: 1) Low boiling point and Low freezing point. 2) Low specific heat and High latent heat. 3) High critical pressure and temperature 4) Low specific volume to reduce the size of the compressor. 5) High thermal conductivity to compact evaporator and condenser. 6) Non-flammable, non-explosive, non-toxic and noncorrosive. 7) High miscibility with lubricating oil 8) High COP in the working temperature range. 9) Compatible with legal requirement 10) Availability and cost Environmental concerns There are two major areas of concern of environmental concern[1]. 1. Depletion of ozone layer - Ozone layer protects the earth from ultraviolet rays.the ozone depletion potential (ODP) of a chemical compound is the relative amount of degradation to the ozone layer it can cause, with reference to trichlorofluoromethane (CFC-11) being fixed at an ODP of 1.0. 2. Global warming - Global warming is the increase in global earth surface temperature due to the absorption of infrared emission from earth surface. Global warming potential (GWP) is evaluated on a scale that uses CO2 as the bench mark i.e. CO2 has been assigned a value of GWP=1 and other components are compared to it. IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 24

According to the Montreal Protocol 1987 [2], developing countries like India, with a per capita consumption of less than 0.3 kg of ozone depleting substances have been categorized as article 5 countries. These countries are required to phase out all chlorofluorocarbons (CFC) by 2010. R12 has been replaced with R134a due to its zero ozone depletion potential (ODP). In India, more than 80% of the refrigerators are working with R134a as refrigerant due to its material compatibility and safety in small capacity refrigeration units. Table 1.1 However, the problem with R134a is that, it has a Global Warming Potential (GWP) of 1300 with respect to Carbon Dioxide. The Kyoto protocol [1] aims at phasing out of substances that will lead to global warming. The increased emission of R134a to the atmosphere are steadily increasing the concentration of green house gases via leaks and mostly, in an indirect way. Due to the above limitations, R134a should be phased out soon Generations of Refrigerants Either or all of the 4 listed requirements are demanding the invention of new generation refrigerants one after another [3]. Zero ozone depletion potential (ODP) Low global warming potential (GWP) Short atmospheric lifetime High efficiency The four generations included slightly overlapping periods as given below: Figure 1.1 Generations of Refrigerants Possible replacements of R134a The possible replacements for R134a are natural refrigerants like carbon dioxide and ammonia, pure hydrocarbons such as R600a and R600, binary and ternary hydrocarbon mixtures, HFC refrigerant (R152a), and hydrofluoroolefins (HFOs, e.g. R1234yf) This paper mainly focuses on the following replacements of R134a 1) HFO-1234yf - The Society of Automotive Engineers (SAE) has proposed 1, 1, 1, 2-tetrafluoroethane (HFC- 134a) to be best replaced by a new refrigerant HFO- 1234yf (CF3CFCH2) in automobile air-conditioning systems. It is being promoted as a possible drop-in replacement for R-134a in both new vehicles and older vehicles, should that become necessary in the future. It has thermal characteristics that are very similar to R- 134a,so no major modifications to the A/C system are necessary. Also, it has a global warming potential of only 4, compared to 1300 for R-134a It would be easy to change to this substance as the existing refrigeration system can be used with no or very simple changes. However, it will be more expensive. 2) R436a - R436a is a blend of two hydrocarbons, propane (R-290) and isobutane (R-600a) in the ratio of 56:44 percent by weight. The various features on account of which it can be considered as a suitable replacement are that it is safe and environment protective. It does not deplete the ozone layer (ODP=0) and nearly zero GWP (less than 3), hence causes negligible greenhouse effect. Since it has similar thermal performance to that of R- 134a, it is compatible with it. It can be used as a drop-in alternative refrigerant for HFC-134a refrigerating systems without changing the compressor, heat exchanger or lubricating oil. Also, it has 50% reduction of charging amount with the same refrigerating system, making it more economical. Comparison Of Properties Of R1234yf And R436a With R134a Table1.2 Critical properties of R134a, R1234yf and R436A IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 25

Table1.3 Critical properties of R134a, R1234yf and R436A Table 2.3 Comparative results of exergy analysis of R1234yf, R436A and R134a at T 1=0.3C and T 3=57.7C From Table 1.3 we observe that the latent heat of R1234yf is 17.8% lower than R134a, which means its performance compared to R134a would be lower, as higher the latent heat, higher is the cooling effect it can produce. Also, its vapour density is 22.2 % higher, which means vapour of R1234yf is heavier, this has implications on container storage and safety. Whereas latent heat of R436A is 85% higher, which suggests it can prove to be a good alternative as it can produce same amount of cooling as R134a but with lesser quantity of refrigerant. The vapour density of R436A is also 56.01% lower than R134a. RESULTS & DISCUSSIONS Assumptions A computational model was developed for arrying out the energetic and exergetic analysis of the system using engineering equation solver software. The properties of pure and mixture refrigerants have been obtained from refprop software version 9.0. The input parameters as per discussion with r&d team of subros limited are as follows: Condenser exit temperature T 3 =57.7 ⁰ C Evaporator exit temperature T 1 =0.3 ⁰ C Degree of superheating in evaporator =10 ⁰ C Degree of Sub-cooling in condenser=5 ⁰ C Isentropic efficiency of compressor=70% Volumetric efficiency of compressor= 65% Compressor displacement=0.004613 m 3 /s Thermodynamic Results The comparative performance is evaluated for condenser temperatures varying between 52.7⁰ C and 62.7⁰ C, and the evaporator temperature is varied between -4.3⁰ C and 6.3⁰ C.the cop at 57.7⁰ C condenser temperature and 0.3⁰ C evaporator temperature for R1234yf is 2.084 and that for R436a is found to be 2.0345 while that for R134a at same temperature conditions is 2.30234 as shown in Table 2.2 Table 2.2 Comparative results of R1234yf, R436A and R134a at T 1=0.3⁰ C and T 3=57.7⁰ C 1) Quality Of Vapour At Inlet To Evaporator Quality of vapour refers to the fraction of vapour in the refrigerant entering the evaporator. When refrigerant enters the evaporator from expansion valve, it is a mixture of liquid and vapour phase. Out of these, only the liquid portion contributes to the cooling effect. Thus, it is desirable to have low quantity of vapour and more of liquid to achieve higher cooling in evaporator. Higher the portion of liquid higher is the cooling effect Figure 2.6 Variation of fraction of vapour with evaporator temperature From Figure 2.6 it is observed that as evaporator exit temperature is increased the quality of refrigerant decreases for all three refrigerants. However, the quality is maximum for R1234yf and least for R436A. Thus, we can conclude that superheating in evaporator could be beneficial. IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 26

Figure 2.7 Variation of fraction of vapour with condenser temperature Figure 2.7 shows the variation of quality of refrigerant at entry to evaporator with condenser temperature. It is seen that quality increases with increase in condenser exit temperature for all the refrigerants. Also, R1234yf has highest fraction of vapour while R436A has least amount of vapour. Thus, R436A is showing favourable behaviour. 2) Effect Of Variation Of Evaporator Temperature Figure 2.9 Variation of exergetic efficiency with evaporator temperature Figure 2.10 shows the variation of exergy destruction ratio with evaporator temperature. As evaporator temperature increases, EDR decreases. The exergy destruction is maximum with R436A, while that of R1234yf is slightly lower. Yet R134a has least value EDR at all values of evaporator temperature. Comparative performance of R134a, R1234yf and R436A was evaluated. The evaporator temperature was varied between -4.7C to 6.3 C. It was found that the general trend is that COP increases with increase in evaporator temperature. Figure 2.8 depicts that COP is maximum for R134a and that of R1234yf and R436A is relatively less. Figure 2.10 Variation of EDR with evaporator temperature 3) Effect Of Variation Of Condenser Temperature As the condenser temperature increases the COP decreases for all the three refrigerants, as shown in Figure 2.11. Figure 2.8 Variation of COP with evaporator temperature Figure 2.9 depicts the variation of exergetic efficiency with evaporator temperature.though it increases with increase in evaporator temperature, the value is maximum for R134a, followed by R1234yf and R436A has the least value Figure 2.11 Effect of variation of condenser temperature on COP From Figure 2.12 it is found that as condenser temperature is increased the exergetic efficiency decreases IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 27

for the three refrigerant. R134a has maximum exergetic efficiency at any temperature. R1234yf has slightly better performance than R436A till condenser temperature of 57.7C beyond which R436A has better exergetic efficiency. Figure 2.14 Effect of superheating on COP Figure 2.12 Effect of variation of condenser temperature on exergetic efficiency As evident from Figure 2.14 COP improves with superheating. However, the rate of increase in COP is higher in R1234yf as compared to R134a and R436A. This is due to greater increase in compressor work relative to the increase in refrigerating effect in R436A and R134a. From Figure 2.13 we can observe that as condenser temperature increases, EDR also increases. R134a has lowest exergy destruction ratio, which means it gives most desirable performance among the three. However R1234yf and R436A have nearly similar values of EDR in the given range of condenser temperature. EDR in R1234yf is initially less but beyond 58.7C, R436A has relatively lower EDR. Figure 2.15: Effect of superheating on exergetic efficiency Figure 2.15 shows that exergetic efficiency improves with superheating of the refrigerant in evaporator. Though R134a has maximum value of exergetic efficiency all temperatures, the rate of increase is highest for R1234yf. Figure 2.13 Effect of variation of condenser temperature on EDR 4) Effect Of Superheating Degree of superheat is the amount by which the temperature of a superheated vapour exceeds the temperature of the saturated vapour at the same pressure. The effect of superheating inside evaporator is to increase the refrigerating effect and hence would give a high value of COP. Thus, superheating inside evaporator is desirable. However,if superheating takes place in suction line, it does not contribute to the refrigerating effect and increases the temperature at inlet to compressor, which is not desirable. Figure 2.16: Effect of superheating on EDR From Figure 2.16 it can be observed that exergy destruction decreases with superheating. Again, the rate of decrease is maximum for R1234yf Thus, we infer from these results that overall superheating in evaporator is beneficial to performance of IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 28

the system. It can help in obtaining the same performance as R134a with R1234yf and R436A in automotive AC system performance of r1234yf and r436a can approach that of r134a in automotive air conditioning system 5) Effect Of Sub-Cooling The term sub-cooling refers to a liquid existing at a temperature below its normal saturation temperature. The effect of sub-cooling is to increase the refrigerating effect. Thus, sub-cooling results in increase of COP provided that no further energy has to be spent to obtain extra cold coolant required. Sub-cooling may take place in heat exchangers or outside them Figure 4.18: Effect of sub-cooling on EDR Figure 2.17: Effect of sub-cooling on COP As is evident from Figure 2.17, COP increases with increasing degree of sub-cool for R134a, R1234yf and R436A. The rate of increase in COP is maximum in case of R1234yf. Thus, we conclude that subcooling is beneficial in a VCR cycle with any refrigerant but with R1234yf the improvement is maximum. Figure 2.18: Effect of sub-cooling on exergetic efficiency From Figure 2.18 it is found that sub-cooling improves the exergetic efficiency with all the refrigerants. However, the increase is more with R1234yf than with R436A. From figure 2.19 it is evident that exergy destruction ratio decreases with increase in degree of sub-cool. thus, we conclude that by increasing the degree of sub-cool, the CONCLUSION The thermodynamic analysis of R1234yf indicates that the COP and exergetic efficiency decreases. However, the system can be modified to match the performance of R134a by introducing an additional internal heat exchanger. Increasing the amount of superheat and subcool can enhance the cooling capacity of the system. Thus it can be used in place of R134a by certain modifications in the system. It was also found that the system should be operated at highest possible evaporator temperature and lowest possible condenser temperature for producing the desired cooling, to achieve maximum COP and exergetic efficiency of the system. REFERENCES [1] Verma J.K., Satsangi A., Chaturani V. A Review of Alternative to R134a Refrigerant International Journal of Emerging Technology and Advanced Engineering, Volume 3, Issue 1, January 2013 [2] M. Mohanraj, Energy performance assessment of R430A as a possible alternative refrigerant to R134a in domestic refrigerators Energy for Sustainable Development 17 (2013). [3] Muthu S., Jaiswal A.K.,' Refrigerant types, issues, trends and future options' ACRECONFINDIA 8th 9th Feb 2013 [4] Calm J.M. The next genration of refrigerants Historical review, considerations and outlook International Journal of refrigeration 31(2008) 1123-1133 [5] Arora CP, Refrigeration and air conditioning Tata McGraw- Hill publishing company limited [6] T.S. Ravikumar, D. Mohan Lal, On-road performance analysis of R134a/R600a/R290 refrigerant mixture in an automobile air-conditioning system with mineral oil as lubricant energy conversion And Management, 2009. [7] Arora A., Arora B.B., PathakB.D. and Sachdev H.L. Exergy analysis of a Vapour Compression Refrigeration system with R-22, R-407C and R-410A Isnt. J. Exergy, Vol. 4, No. 4, 2007 IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 29

[8] Xuquan Li, Jiangping Chen, Zhijiu Chen, Weihua Liu, Wei Hu, Xiaobing Liu A new method for controlling refrigerant flow in automobile air conditioning,2003 [9] G.H Lee, J.Y. Yoo Performance analysis and simulation of automobile air conditioning.1999 [10] Sergio Bobbo,Zilio,Scatollini R1234yf as a substitute of R134a in automotive air conditioning. Solubility measurements in two commercial PAG oils,2013 [11] Yohan Lee, Dongsoo Jung, A brief performance comparison of R1234yf and R134a in a bench tester for automobile applications, Applied Thermal Engineering 35 (2012) IJAPIE ISSN: 2455 8419 www.ijapie.org Inn Des & Com Mod Sp.Issue 2017 30