RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

Similar documents
Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Tebis application software

Tebis application software

Application description

Devices for Special Applications

Description of the application programme for KNX occupancy detectors version 3.1

0701 CO Light, HVAC, Monitoring, Brightness

Product and Applications Description

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

OPERATING INSTRUCTIONS

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

Technical Manual MDT Motion Detector

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

Use of the application program

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

UP 258E11 OPTISENS OFFICE

Connections, displays and operating elements C D E G H. Installing the control unit

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

Sensors SR Programming manual

Sensors SR Programming manual

Info-Display xx

Controller - 4 x 1-10 V outputs - BUS/KNX

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

B.E.G. Already heard of it? News

Lennox Climatic 50 and BMS Modbus, Trend or BACnet.

Install intelligent room automation flexibly and future-proofed

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

Installer Manual KNX Touchscreen Thermostat

Product and Applications Description

HM-4201-RTCM High-Temp Real Time Clock Module

User Manual Doc.Ref : JA-KNX-UM. JA-KNX Jablotron KNX Interface ELAUSYS JA-KNX. KNX Interface for Jablotron alarm system.

ABB i-bus EIB. Energy-optimised buildings. For authorised electricians only

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

CBI-064. User Manual. Caddx to KNX-BUS Interface

B.E.G. PRESS KIT 2013

Operating instructions

FIB_FGBS-001 Universal Binary Sensor

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

Smoke Detector and Siren. Manual

KNX/EIB - Product database - Application description

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

B.E.G. LUXOMAT net. KNX intelligent building automation using sensors from B.E.G.

ST3124. KNX Blind Actuator DC 4-fold. Operation and Installation Manual

NOVEMBER 2017 Webinar New KNX Devices Nov JRA/S , LGS/A 1.2, TR/A 1.1. Webinar Competence Center Europe Building Automation

Auro KNX Manual. Auro KNX. Manual. basalte bvba hundelgemsesteenweg 1a 9820 merelbeke belgium. 1 / 23 v basalte

HM-4201-RTCM High-Temp Real Time Clock Module

Synco-GAMMA Application Guide. Hotel buildings. Answers for infrastructure.

Synco-Gamma Application Guide. Retirement and nursing homes.

Highlights. SMARTHOME product combinations. Starter Set 4 radiator control for saving energy wirelessly controlled 2013/1.

PBI Manual. Paradox to KNX-BUS Interface

Synco living. Train the Trainer. Commissioning Safety & Security. Spring 2008 Page 1/21 Train the Trainer - Spring 2008

Tebis application software

Connections, displays and operating elements E F. 20s 3min

600 Watt Dimmer Install Guide

Electronic controllers. Comfort embellishes everyday life

KNX / EIB Product Documentation Page: 1 of 81

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Passive infrared ceiling sensor

Product and functional description

Roth Touchline. German quality since Quick and easy user manual 1/10

Product Guide

ABB STOTZ-KONTAKT GmbH Webinar ABB i-bus KNX Security Module SCM/S

IP65 High Bay Dual Sense Sensor

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

Model: Touch-RF. 1 Wireless Series

Transponder reader TECHNICAL SHEET (White) (Magnesium)

IP65 High Bay Dual Sense Sensor

Watts Under Floor Multi-zone Controller User Manual

KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX

SRT321 User and Installation Instructions

Building and home evolution

TER Active Room Temperature Sensor (Controller),

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM

Synco living Operating instructions. Building Technologies

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Du line. Mastergenerator G3800 X016. Operation Manual. Fieldbus Installationbus

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Movement controller comfort, Flush-mounted (Up) xx, xx

DOCUMENTATION IPS640

Security, Efficiency and Comfort with KNX

e-sense move dali Manual

Instruction Manual Water Sensor

Instruction Manual Contact Sensor

Sensors and Detectors

HOME AUTOMATION, INC. Lumina and Lumina Pro Lighting and Automation System. Quick-Start Installation Guide

NEW. lighting management - stand alone detectors, power packs. Passage detection - Infrared technology. Detectors with power packs

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Smart home and building solutions. Global. Secure. Connected. Advantages of KNX. September 2018

Serie µbrick Decentralised - Compact - Functional - Favorable

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Mobeye CM2410 GSM fire alarm communicator

INNOVATIVE TRAINING SYSTEMS FOR FUTURE ENGINEERS

2016 PRODUCT OVERVIEW

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

LightStation by SENNA

WIRELESS MOTION SENSOR USER MANUAL MULTI LANGUAGE START-LINE TRANSMITTER AWST-6000

Synco 900 Operating Instructions. Edition 1.0 Controller series 1 CE1B2707en Building Technologies HVAC Products

Transcription:

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002 INSTRUCTIONS MANUAL Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 1

General Description RF-KNX / TP-KNX media coupler. Bidirectional Gateway between radio-frequency devices and the KNX Bus. It allows the transmission of telegrams from the radio devices to the TP-KNX communication bus and vice versa. Can be used with devices to control lighting, HVAC, blinds/shutters and general purpose devices. The CO KNX 002 comes with 16 RF or TP independent channels. The configuration is done using the ETS4. The CO KNX 002 has: A: KNX standard connecting terminal. B (TP prog): green/red LED-key for the commissioning by ETS. C: RF working mode selector switch: P: Link Programming. R: Standard operation + Repeater function. S: Standard operation. E: Erase one link. EA: Erase All links. D: selector (up to 16 channels: 0, 1, 2, 3, 4,...F). E (RF prog): green/red LED-key for learning RF devices. C B A D E Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 2

Technical Data Power supply 21 ~ 32 VDC (via Bus) Power consumption < XmA Bus connection Connecting terminal Number of channels RF-TP / TP-RF: 16 channels TP Group address 250 TP links 250 Commissioning ETS4 Communication Bidirectional Frequency 868,4MHz. Compatible with RF-KNX RF telegram repetition 2 times Range 100 meters (in the free field) Dimensions 38 x 42 x 15mm Working temperature -5ºC ~ +45ºC Storage temperature -20ºC ~ +70ºC Protection degree IP20 (EN60529) Protection class III Mounting Junction box According to the Standard EN50090-2-2, EN50428 & EN50491 Marking EIB/KNX Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 3

Installation and Commissioning The CO KNX 002 media coupler has a standard terminal (A) for the connection to the Bus. The operation of the product is subject to the configuration done using the ETS3 or ETS4. You can download the application software on our website: www.dinuy.com. a) TP Commissioning For installation and commissioning of the device, follow these steps: - 1º: Connect the CO KNX 002 media coupler to the KNX Bus. - 2º: Assign physical address and assign parameters to the application program. - 3º: Press briefly the programming key (B). The green LED will permanently light and the device will be ready to be programmed by ETS. After the programming (30sec) the LED will flicker in red. - 4º: Once programmed, the LED will be off. b) RF Learning Process In order to link the CO KNX 002 with a wireless device, follow these steps: - 1º: Set the channel selector (D) at the corresponding position, according to the previously configured by the ETS. Choose the channel in which is going to be programmed the RF device. - 2º: Place the mode selector switch (C) at P position (link mode). - 3º: The LED-key (E) will flicker slowly in green. - 4º: Press briefly the LED-key (E). It will start flickering quickly in green. At this moment is ready to receive the RF signal from a RF sensor or actuator. - 5º: Follow the instructions for programming the RF sensor or actuator to send its link code. - 6º: If the link is successful, the LED-key (E) will flash five times in red and then it will return to blink slowly in green. - 7º: Set the mode switch (C) to S (normal operation) or to R (normal + repeater). In both modes the LED-key will be in green. b.1- Erasing a RF link (E) In order to do a partial deletion of a link, the next steps must be followed: - 1º: Place the mode selector switch (C) to E (link erasing). The LED-key will be permanently in green. - 2º: Press briefly the LED-key (E). It will start flickering quickly in green. At this moment is ready to receive the RF signal from a RF sensor or actuator. - 3º: Follow the instructions for deleting the RF sensor or actuator. - 4º: If the deletion is successful, the LED-key (E) will flash five times in red and then it will return to light permanently in green. b.2- RF Complete Deletion (EA: Reset) In order to do a complete deletion, the next steps must be followed: - 1º: Place the mode switch (C) to EA (Erase All). The LED-key (E) will flicker quickly in green. - 2º: Press the LED-key (E) for longer than 4 seconds. - 3º: If the deletion is successful, the LED-key (E) will be 4 seconds in green and then it will flicker quickly. Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 4

LIGHT CHANNEL Project Development and Commissioning Switch_OnOff_Status Input Info On Off Input 1 bit - on/off Baja 0002h CH PB Toggle 0003h CH PB Timed Timed Start Stop output Timed Start Stop output 1 bit start/stop Baja 0004h CH PB Timed Info Timed Start Stop output Timed Start Stop output 1 bit start/stop Baja 0005h CH PB Dimmer Dimming Ctrl output Relative Setvalue Control 4 bits dimming control Baja Dimming Ctrl output Dimming Ctrl output 4 bits dimming control Baja 0006h CH PB Dimmer Toggle Dimming Ctrl output Dimming Ctrl output 4 bits dimming control Baja 0007h CH PB Scene Numbered Scene number output Scene number output 1 Byte scene control Baja SENSOR 0008h CH PB Scene Scene AB Activate output Scene AB Activate output 1 bit scene A/B Baja Scene AB Learn output Scene AB Learn output 1 bit state Baja 0009h CH Switch 000Ah CH Switch Info Switch_OnOff _Status input Switch_OnOff_Status Input 1 bit - on/off Baja 000Bh CH Switch Forced Forced output Forced output 2 bits switch control Baja 000Ch CH Switch Dimmer Dimming Ctrl output Relative Setvalue Control 4 bits dimming control Baja 000Dh CH Switch Dimmer Info Switch_OnOff_output Switch_OnOff output 1 bit on/off Baja Dimming Ctrl output Dimming Ctrl output 4 bits dimming control Baja Switch_OnOff_Status Input Info On Off Input 1 bit - on/off Baja 000Eh CH Switch Dimmer Toggle Dimming Ctrl output Dimming Ctrl output 4 bits dimming control Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 5

LIGHT CHANNEL 000Fh CH Switch Scene Numberted Scene number output Scene number output 1 Byte scene control Baja 0010h CH Switch Scene Scene AB Activate output Scene AB Activate output 1 bit scene A/B Baja Scene AB Learn output Scene AB Learn output 1 bit state Baja Dimming Ctrl Input Relative Setvalue Control 4 bits - dimming control Baja 0011h CH Light Setpoint Controller Forced input Forced input 2 bits - switch control Baja Room illumination Input Room illumination Input 2 Bytes - lux (Lux) Baja Scene number Input Scene number Input 1 Byte - scene control Baja Dimming value output Dimming value output 1 Byte percentage (0..100%) Baja 0012h CH Light Sensor Room illumination Output Room illumination Output 2 Bytes lux (Lux) Baja SENSOR 0013h CH Motion Detector Basic Switch_OnOff_Status input Switch_OnOff_Status Input 1 bit - on/off Baja Timed Start Stop output Timed Start Stop output 1 bit start/stop Baja 0014h CH Motion Detector Complex Enable Input Enable Input 1 bit - enable Baja Timed Start Stop output Timed Start Stop output 1 bit start/stop Baja 001Eh CH Switch Operation Mode Operation Mode Output Operation Mode Output 1 bit on/off Baja 0020h CH PushButton 0029h CH PB Dimming Value Dimming value output Dimming value output 1 Byte percentage (0..100%) Baja 002Ah CH Push Button Info 002Ch CH PB Dimming Value Info 002Dh CH Dimming Value Info Dimming value output Dimming value output 1 Byte percentage (0..100%) Baja Switch_OnOff_Status input Switch_OnOff_Status Input 1 bit - on/off Baja Dimming value output Dimming value output 1 Byte percentage (0..100%) Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 6

LIGHT CHANNEL 0100h CH Status Info 0101h CH Binary Basic Switch_OnOff_Status Output Switch_OnOff_Status Output 1 bit on/off Baja 0102h CH Light Complex Timed Start Stop Input Timed Start Stop Input 1 bit - start/stop Baja Forced input Forced input 2 bits - switch control Baja Switch_OnOff_Status Output Switch_OnOff_Status Output 2 bits - switch control Baja Timed Start Stop Input Timed Start Stop Input 1 bit - start/stop Baja ACTUATOR 0103h CH Light Scene 0104h CH Light Controlled 0105h CH Dimming Basic Forced input Forced input 2 bits - switch control Baja Scene number Input Scene number Input 1 Byte - scene control Baja Switch_OnOff_Status Output Switch_OnOff_Status Output 1 bit on/off Baja Operation Mode Input Operation Mode Input 1 bit - on/off Baja Switch_OnOff_Status Output Switch_OnOff_Status Output 1 bit on/off Baja Dimming Ctrl Input Dimming Ctrl Input 4 bits - dimming control Baja Dimming value Input Dimming value Input 1 Byte - percentage (0..100%) Baja Switch_OnOff_Status Output Switch_OnOff_Status Output 2 bits - switch control Baja Dimming value Status output Dimming value Status output 1 Byte percentage (0..100%) Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 7

LIGHT CHANNEL Dimming Ctrl Input Dimming Ctrl Input 4 bits - dimming control Baja Dimming value Input Dimming value Input 1 Byte - percentage (0..100%) Baja 0106h CH Dimming Complex Timed Start Stop Input Timed Start Stop Input 1 bit - on/off Baja Forced input Forced input 2 bits - boolean control Baja Switch_OnOff_Status Output Switch_OnOff_Status Output 1 bit on/off Baja Dimming value Status output Dimming value Status output 1 Byte percentage (0..100%) Baja Dimming Ctrl Input Dimming Ctrl Input 4 bits - dimming control Baja Dimming value Input Dimming value Input 1 Byte - percentage (0..100%) Baja ACTUATOR 0107h CH Dimming Scene Timed Start Stop Input Timed Start Stop Input 1 bit - on/off Baja Forced input Forced input 2 bits - boolean control Baja Scene number Input Scene number Input 1 Byte - scene control Baja Switch_OnOff_Status Output Switch_OnOff_Status Output 1 bit on/off Baja Dimming value Status output Dimming value Status output 1 Byte percentage (0..100%) Baja 020Ah CH LightSensor Slave Room illumination Output Room illumination Output 2 Bytes - lux (Lux) Baja Dimming Ctrl Input Relative Setvalue Control 4 bits - dimming control Baja 020Bh CH Light Setpoint Controller Info Forced input Forced input 2 bits - switch control Baja Scene number Input Scene number Input 1 Byte - scene control Baja Dimming value output Dimming value output 1 Byte percentage (0..100%) Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 8

HVAC CHANNEL SENSOR ACTUATOR 0024h CH Outside Temperature Sensor TempOutside Output TempOutside Output 2 Bytes temperature (ºC) Baja 0025h CH Room Temperature Sensor Room Temperature Output Room Temperature Output 2 Bytes temperature (ºC) Baja 0027h CH PB HVAC Mode HVAC Mode Output HVAC Mode Output 1 Byte HVAC mode Baja 0028h CH Switch HVAC Heating Enabled Heating Enabled Output Heating Enabled Output 1 bit enable Baja 002Eh CH HVAC Mode 1 HVAC Mode Output HVAC Mode Output 1 Byte HVAC mode Baja 0207h CH HVAC Mode Scheduler HVAC Mode Output HVAC Mode Output 1 Byte HVAC mode Baja CH PresenceHeating Presence Heating Output Presence Heating Output 1 bit 1-bit Baja CH TempRoomSetpUserAbs TempRoomSetpUserAbs Output TempRoomSetpUserAbs Output 2 Bytes temperature (ºC) Baja 0501h CH Heating Valve Valve Input Valve Input 1 Byte percentage (0..100%) Baja 0502h CH HVACMode Display HVAC Mode Status Input HVAC Mode Status Input 1 Byte temperature (ºC) Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 9

COMMON CHANNEL SENSOR 001Fh CH Logical Sensor Logical Value Output Logical Value Output 1 bit on/off Baja 0021h CH Battery Status Battery Status Output Battery Status Output 1 bit on/off, binary value Baja 0022h CH Smoke Detector Basic Smoke Alarm Output Smoke Alarm Output 1 bit alarm Baja 0023h CH Window Door Contact Basic Window Status Output Window Status Output 1 bit open window or door Baja Switch_OnOff_Status input Switch_OnOff_Status input 1 bit - on/off Baja 002Bh CH Forced Info Forced output Forced output 2 bits boolean control Baja System Clock Master Date output Date output 3 Bytes date Baja Time output Time output 3 Bytes time of day Baja 010Eh CH Logical Logical Value Input Logical Value Input 1 bit - boolean Baja 0120h CH Info Adaptable INFO_8BIT Input INFO_8BIT Input 1 Byte - INFO_16BIT Input INFO_16BIT Input 2 Bytes - scene number, scene control, 1-byte, character, 8-bit unsigned value, 8-bit signed value datapoint type version, 16-bit set, language code ISO 639-1, 2-byte unsigned, 2-byte signed, 2-byte float INFO_1BIT Input INFO_1BIT Input 1 bit - 1-bit Baja Baja Baja ACTUATOR 0200h Logic AndOr 0203 CH Scene Converter System Clock Slave Logical value 1 Input Logical value 1 Input 1 bit - 1-bit Baja Logical value 2 Input Logical value 2 Input 1 bit - 1-bit Baja Logical value 3 Input Logical value 3 Input 1 bit - 1-bit Baja Logical value 4 Input Logical value 4 Input 1 bit - 1-bit Baja Logical result Logical result 1 bit 1-bit Baja Scene Activate Input Scene Activate Input 1 bit - scene A/B Baja Scene Learn Input Scene Learn Input 1 bit state Baja Scene_Number Output Scene_Number Output 1 Byte scene control Baja Date Input Date Input 3 Bytes - date Baja Time Input Time Input 3 Bytes - time of day Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 10

SHUTTERS AND BLINDS CHANNEL UpDown Output Move UpDown Output 1 bit up/down Baja 0015h CH Switch Shutter Stop Output Stop Output 1 bit step Baja 0016h CH Switch Blind 0017h CH PB Shutter 0018h PB Blind UpDown Output Move UpDown Output 1 bit up/down Baja StepStop_UpDown Output StepStop_UpDown Output 4 bits blind control Baja UpDown Output Move UpDown Output 1 bit up/down Baja Stop Output Stop Output 1 bit step Baja UpDown Output UpDown Output 1 bit up/down Baja StepStop_UpDown Output StepStop_UpDown Output 4 bits blind control Baja Move UpDown Input Status Move UpDown Input Status 1 bit - up/down Baja SENSOR 0019h CH PB Shutter Toggle 001Ah CH PB Blind Toggle Move UpDown Output Move UpDown Output 1 bit up/down Baja Stop Output Stop Output 1 bit step Baja Move UpDown Input Status Move UpDown Input Status 1 bit - up/down Baja Move UpDown Output Move UpDown Output 1 bit up/down Baja StepStop_UpDown Output StepStop_UpDown Output 4 bits blind control Baja 001Bh CH Wind Alarm Sensor Wind detected output Wind detected output 1 bit alarm Baja 001Ch CH Rain Alarm Sensor Rain Alarm Output Rain Alarm Output 1 bit alarm Baja 001Dh CH Frost Alarm Sensor Frost Alarm Output Frost Alarm Output 1 bit alarm Baja 002Fh CH PB Shutter 1 UpDown Output Move UpDown Output 1 bit up/down Baja Stop Output Stop Output 1 bit step Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 11

SHUTTERS AND BLINDS CHANNEL 0108h CH Shutter Basic Wind Wind detected input Wind detected input 1 bit - alarm Baja 0108h CH ShutterBlinds Basic Wind Wind detected input Wind detected input 1 bit - alarm Baja ACTUATOR 010Ah CH Shutter Basic Rain 010Bh CH ShutterBlinds Basic Rain 010Ch CH ShutterBlinds Basic Rain alarm input Rain alarm input 1 bit - alarm Baja Rain alarm input Rain alarm input 1 bit - alarm Baja Wind detected input Wind detected input 1 bit - alarm Baja Rain alarm input Rain alarm input 1 bit - alarm Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 12

SHUTTERS AND BLINDS CHANNEL Forced Input Forced Input 2 bits - switch control Baja 010Dh CH ShutterBlinds Scene Wind detected input Wind detected input 1 bit - alarm Baja Rain alarm input Rain alarm input 1 bit - alarm Baja Scene number Input Scene number Input 1 Byte - scene control Baja ACTUATOR Forced Input Forced Input 2 bits - switch control Baja 0480h CH ShutterBlinds Scene 1 Wind detected input Wind detected input 1 bit - alarm Baja Rain alarm input Rain alarm input 1 bit - alarm Baja Scene number Input Scene number Input 1 Byte - scene control Baja Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 13