ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Similar documents
ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Installation Guide for models:

Series. Access Power Controllers. Installation Guide

Installation Guide for models:

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Access Power Controllers with Power Supplies

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Rack Mount Series Installation Guide

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

AL800ULADA. NAC Power Extender. Installation Guide

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AL600ULX Series. Power Supply/Charger. Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

more than just power! Altronix is the professional security industry s leading manufacturer

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

SP-1000X. Panic Device Power Controller Installation Guide. Rev

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL602ULADA AL802ULADA AL1002ULADA

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Power Supplies. Overview

KT-100 Door Controller

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Installation Instructions

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

4100U City and Relay Cards Installation Instructions

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

DS160/161 Request To Exit PIR sensors Installation Instructions

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

HARDwired Installation/ Owner s Manual

PSN-1000 & PSN 1000(E) Installation Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

WM3000 WIRELESS MODULES

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Conventional Releasing Control Panel

TECHNICAL DATA OBSOLETE

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Excel-EN Conventional Fire Control Panel

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

RELEASE DEVICE CONTROLS

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

MODEL B2 INSTALLATION MANUAL

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Section 1 General Description

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

631RF Amp Power Supply

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

/ How To Order

Commercial and Light Industrial Fire Alarm Control Panel

STANDARD FEATURES SPECIFICATIONS

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MR-2602 Two Zone Fire Alarm Control Panel

Notification Appliance Circuit Module

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

DE5300 Delayed Egress System. General Information

Model 4001 Series Single Channel Controller

ACCURATE ELECTRONICS INC

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Installation Manual RINS1211-4

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Connections. Application Note Jeronimo Rd. Irvine, CA February 20, 2008 Document Number AN0108, Rev A.1

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

2409/2900. Fire Guard

ESP TECHNOLOGIES LIMITED

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

Addendum for STI-6406 with Dual Access Control

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Transcription:

ACM8 & ACM8CB Access Power Controllers Installation Guide Models Include: ACM8 ACM8E - Fused Outputs - Fused Outputs ACM8CBE ACM8CB - PTC Outputs - PTC Outputs Rev. 092503

Overview: These units convert one (1) 12 to 24 volt AC or DC input into eight (8) independently controlled fused or PTC protected outputs. These power outputs can be converted to dry form C contacts (ACM8 & ACM8E only). Outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Card Reader, Keypad, Push Button, PIR, etc. The units will route power to a variety of access control hardware devices including Mag Locks, Electric Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units are designed to be powered by one common power source which will provide power for both the board operation and locking devices, or two (2) totally independent power sources, one (1) providing power for board operation and the other for lock / accessory power. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the eight (8) outputs. Altronix Model Number ACM8 & ACM8CB Series Configuration Reference Chart: Fuse Protected Outputs PTC Protected Outputs Output Ratings Enclosure Power Limited Agency Listings UL Listings and File Numbers ACM8 x - 3.5 amp * UL294 (File# BP6714) ACM8E x - 3.5 amp x * UL294 (File# BP6714) ACM8CB - x 2.5 amp x UL294 (File# BP6714) ACM8CBE - x 2.5 amp x x UL294 (File# BP6714) *When used with Power Limited power supply. Specifications: 12 to 24volt AC or DC operation (setting not required). (.6 amp @ 12volt,.3 amp @ 24volt current consumption with all relays energized). Power supply input options: a) One (1) common power input (board and lock power). b) Two (2) isolated power inputs (one (1) for board power and one (1) for lock/hardware power). Eight (8) Access Control System trigger inputs: a) Eight (8) normally open (NO) inputs. b) Eight (8) open collector sink inputs. c) Any combination of the above. Eight (8) independently controlled outputs: a) Eight (8) Fail-Safe and/or Fail-Secure power outputs. b) Eight (8) dry form C 5 amp rated relay outputs (ACM8 & ACM8E only). c) Any combination of the above (ACM8 & ACM8E only). Eight (8) auxiliary power outputs (unswitched). Output ratings: - Fuses are rated 3.5 amp each. - PTCs are rated 2.5 amp each. Main fuse is rated at 10 amp. Note: Total output current is determined by the power supply, not to exceed a maximum of 10 amp total. Red LEDs indicate outputs are triggered (relays energized). Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs. Fire Alarm disconnect input options: a) Normally open (NO) or normally closed (NC) dry contact input. b) Polarity reversal input from FACP signaling circuit. FACP output relay (form C contact rated @ 1 amp 28VDC not evaluated by UL). Green LED indicates when FACP disconnect is triggered. Removable terminal blocks facilitate ease of installation. Board Dimensions (approximate): 8 L x 4.5 W x 1.25 H (ACM8 and ACM8CB) Enclosure Dimentions: 13.5"H x 13"W x 3.5"D (ACM8E and ACM8CBE) - 2 -

Installation Instructions: 1. Mount unit in desired location/enclosure. Carefully review: Typical Application Diagram (pg. 4) Terminal Identification Table (pg. 5) LED Diagnostics (pg. 5) Hook-up Diagrams (pg. 6) 2. Power supply input: The units can be powered with one (1) power supply which will provide power for both board operation and the locking devices or two (2) separate power supplies, one (1) to provide power for the board operation and the other to provide power for the locking devices and/or access control hardware. Note: The input power can be either 12 to 24 volts AC or DC (.6 amp @ 12volt,.3 amp @ 24volt current consumption with all relays energized). (a) Single power supply input: If the unit and the locking devices are to be powered using a single power supply, connect the output (12 to 24 volts AC or DC) to the terminals marked [- Control +]. (b) Dual power supply inputs (Fig. 1, pg. 4): When the use of two power supplies is desired, jumpers J1 and J2 (located to the left of the power/control terminals) must be cut. Connect power for the unit to the terminals marked [- Control +] and connect power for the locking devices to the terminals marked [- Power +]. Note: When using DC power supplies polarity must be observed. When using AC power supplies polarity need not be observed. Note: For UL compliance the power supplies must be UL Listed for Access Control Systems and accessories. 3. Output options (Fig. 1, pg. 4): The ACM8/ACM8E will provide either eight (8) switched power outputs, eight (8) dry form C outputs, or any combination of of both switched power and form C outputs, plus eight (8) unswitched auxiliary power outputs. The ACM8CB/ACM8CBE will provide eight (8) switched power outputs or eight (8) unswitched auxiliary power outputs. (a) Switched Power outputs: Connect the negative (-) input of the device being powered to the terminal marked [COM]. For Fail-Safe operation connect the positive (+) input of the device being powered to the terminal marked [NC]. For Fail-Secure operation connect the positive (+) input of the device being powered to the terminal marked [NO]. (b) Form C outputs (ACM8 & ACM8E): When form C outputs are desired the corresponding output fuse (1-8) must be removed. Connect negative (-) of the power supply directly to the locking device. Connect the positive (+) of the power supply to the terminal marked [C]. For Fail-Safe operation connect the positive (+) of the device being powered to the terminal marked NC]. For Fail-Secure operation connect the positive (+) of the device being powered to the terminal marked [NO]. (c) Auxiliary Power outputs (unswitched): Connect positive (+) input of the device being powered to the terminal marked [C] and the negative (-) of the device being powered to the terminal marked [COM]. Output can be used to provide power for card readers, keypads etc. 4. Input trigger options (Fig. 1, pg. 4): (a) Normally Open [NO] input trigger: Inputs 1-8 are activated by normally open or open collector sink inputs. Connect devices (card readers, keypads, request to exit buttons etc.) to terminals marked [IN] and [GND]. (b) Open Collector Sink inputs: Connect the access control panel open collector sink positive (+) to the terminal marked [IN] and the negative (-) to the terminal marked [GND]. 5. Fire Alarm Interface options (Figs. 3 through 7, pg. 6): A normally closed [NC], normally open [NO] input or polarity reversal input from FACP signaling circuit will trigger selected outputs. To enable FACP Disconnect for an output open the corresponding switch [SW1-SW8]. To disable FACP disconnect for an output close the corresponding switch [SW1-SW8]. (a) Normally Open [NO] input: For non-latching hook-up (Fig. 4, pg. 6). For latching hook-up (Fig. 5, pg. 6). (b) Normally Closed [NC] input: For non-latching hook-up (Fig. 6, pg. 6). For latching hook-up (Fig. 7, pg. 6). (c) FACP Signaling Circuit input trigger: Connect the positive (+) and negative (-) from the FACP signaling circuit output to the terminals marked [+ INP -]. Connect the FACP EOL to the terminals marked [+ RET -] (polarity is referenced in an alarm condition). - 3 -

Jumper must be cut (Fig. 3, pg. 6). 6. FACP Dry form C output (Fig. 1A, pg. 4): Connect desired device to be triggered by the unit s dry contact output to the terminals marked [NO] and [C] FACP for normally open output or the terminals marked [NC] and [C] FACP for normally closed output. Fig. 1 ACCESS CONTROL PANEL OUTPUT RELAY ACCESS POWER CONTROLLER LED1 C NO NC F1 1 2 3 4 Typical Application Diagram: 5 6 7 8 ALTRONIX CORP. BKLYN, NY 11220 MADE IN USA F2 F3 F4 F5 F6 F7 F8 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V SW1 SW2 SW3 NORMALLY OPEN N.O. DOOR RELEASING DEVICE SW4 LED2 LED3 LED4 LED5 LED6 LED7 LED8 SW5 SW6 KEYPAD SW7 SW8 FACP (Fire Alarm Control Panel) 10A 250V MAIN + INP --- T + RET - FACP INTERFACE FACP Dry Form "C" Output SW1-SW8 Fig. 1A FACP FACP Interface Enabled FACP Interface Disabled MAG. LOCK J2 J1 --- + Control NC C NO COM OUTPUT 1 NC C NO COM OUTPUT 2 NC C NO COM NC C NO COM OUTPUT 3 OUTPUT 4 NC C NO COM NC C NO COM OUTPUT 5 OUTPUT 6 NC C NO COM NC C NO COM OUTPUT 7 OUTPUT 8 --- + Power ELECTRIC STRIKE ELECTROMAGNETIC DOOR HOLDERS UL Listed POWER SUPPLY For this application corresponding fuse F8 must be removed. MAG. LOCK AC or DC POWER SUPPLY (optional) AC or DC POWER SUPPLY (req'd.) ACM8/ACM8E ACM8CB/ACM8CBE F1 F2 F1 F2 3.5A 250V 3.5A 250V 3.5A 250V 3.5A 250V SW1 SW2 SW1 SW2 LED1 LED2 LED1 LED2-4 -

ACM8 & ACM8CB Access Power Controller LED Diagnostics: LED ON OFF LED 1- LED 8 (Red) Output relay(s) energized. Output relay(s) de-energized. Trg (Green) FACP input triggered (alarm condition). FACP normal (non-alarm condition). Terminal Identification Tables: ACM8 & ACM8CB Access Power Controller Terminal Function/Description Legend - Power + 12VDC or 24VDC input from power supply board. - Control + These terminals can be connected to a separate, UL listed power supply to provide isolated operating power for the ACM8/ACM8E/ACM8CB/ACM8CBE (jumpers J1and J2 Must be removed). TRIGGER From normally open and/or open collector sink trigger inputs INPUT 1- INPUT 8 (request to exit buttons, exit pir s, etc.). IN, GND OUTPUT 1-OUTPUT 8 12 to 24 volts AC/DC trigger controlled outputs: NC, C, NO, COM Fail-Safe [NC positive (+) & COM Negative (-)], Fail-Secure [NO positive (+) & COM Negative (-)], Auxiliary output [C positive (+) & COM Negative (-)] (When using AC power supplies polarity need not be observed), NC, C, NO become form C 5 amp 24VAC/VDC rated dry outputs when fuses are removed (ACM8/ACM8E). Contacts shown in a non-triggered state. FACP INTERFACE Fire Alarm Interface trigger input from FACP. Trigger inputs can be normally open, T, + INPUT - normally closed from an FACP output circuit (Fig. 3 through 7, pg. 6). FACP INTERFACE Form C relay contact rated @ 1 amp 28VDC for alarm reporting. NC, C, NO (This output has not been evaluated by UL). - 5 -

Hook-up Diagrams: Fig. 2 CUT JUMPERS J1 AND J2 Optional hook-up using two (2) isolated power supply inputs: Fig. 3 Polarity reversal input from FACP signaling circuit output (polarity is referenced in alarm condition): CUT JUMPER J2 J1 ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (ACM8 POWER) ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (LOCK POWER) FACP INTERFACE FACP OUTPUT EOL -- + FROM FACP OUTPUT CIRCUIT Fig. 4 Normally Open - Non-Latching FACP trigger input: Fig. 5 Normally Open FACP Latching trigger input with reset: (This output has not been evaluated by UL) FACP INTERFACE N.O. TRIGGER INPUT JUMPER N.O. TRIGGER INPUT N.C. RESET SWITCH Fig. 6 Normally Closed - Non-Latching FACP trigger input: Fig. 7 Normally Closed - Latching FACP trigger input with reset: (This output has not been evaluated by UL) FACP INTERFACE JUMPER N.C. DRY TRIGGER INPUT JUMPER N.C. RESET SWITCH N.C. TRIGGER INPUT - 6 -

13 H x 13.5 W x 3.25 D Enclosure Dimensions (ACM8E/ACM8CBE): 3.25" TOP ONLY 1.1875" 3.25" 1.1875" 0 0 0 0.75" 1.5" 6.25" 11" 11.75"12.5" 0 1.1875" 3.25".81" 1.4" 1.4" 5.5" 6.5" 11.66" 12.1" 13" - 7 -

ME Notes: Altronix is not responsible for any typographical errors. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIACM8/ACM8CB series I01D - 8 - MEMBER