Series. Access Power Controllers. Installation Guide

Similar documents
Installation Guide for models:

Installation Guide for models:

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Access Power Controllers with Power Supplies

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

ACM8 & ACM8CB. Access Power Controllers Installation Guide. - Fused Outputs - Fused Outputs. - PTC Outputs - PTC Outputs. Models Include: Rev.

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Rack Mount Series Installation Guide

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

AL600ULX Series. Power Supply/Charger. Installation Guide

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

AL600ULADA. NAC Power Extender. Installation Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

more than just power! Altronix is the professional security industry s leading manufacturer

Booster Power Supply Manual

IP Access FACP Adapters. Installation Guide. Entrada2DMK - IP Access FACP Adapter Kit. Kit Includes: Entrada2DMR - IP Access FACP Receiver

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

PDD-8PCI. Power Distribution Board With Supervised Interface. Installation and Specifications Manual

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

MR-2602 Two Zone Fire Alarm Control Panel

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

PSN-1000 & PSN 1000(E) Installation Manual

TECHNICAL DATA OBSOLETE

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Public Safety DAS Annunciator Panel

MODEL B2 INSTALLATION MANUAL

KT-100 Door Controller

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

MANUAL RESET ALARM RELEASE

Power Supplies. Overview

Remote NAC Power Supply D7038

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

4100U City and Relay Cards Installation Instructions

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Model 17A00 Expansion Enclosure

EVO192 v3.0 Fire and Burglary What s New

July 14, 1999 DF C-100.

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

MANUAL RESET ALARM RELEASE

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

AL602ULADA AL802ULADA AL1002ULADA

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

MANUAL RESET ALARM RELEASE BOX

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

June 10, 2002 DF C S2424

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

INSTALLATIONN GUIDE & OPERATION MANUAL

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Addressable NAC Output Module D327A

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

RELEASE DEVICE CONTROLS

Notification Appliance Circuit Module

30.45 Electric Release PDRP-2001

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Transcription:

Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse protected power-limted outputs. Maxim33 - Power Supply 1: 12VDC @ 5.5 amp or 24VDC @ 5.7 amp. - Power Supply 2: 12VDC @ 5.5 amp or 24VDC @ 5.7 amp. - Sixteen (16) fuse protected non power-limted outputs. Maxim55 - Power Supply 1: 12VDC @ 9.5 amp. - Power Supply 2: 12VDC @ 9.5 amp. - Sixteen (16) fuse protected non power-limited outputs. Maxim77 - Power Supply 1: 24VDC @ 9.7 amp. - Power Supply 2: 24VDC @ 9.7 amp. - Sixteen (16) fuse protected non power-limited outputs. Maxim75 - Power Supply 1: 12VDC @ 9.5 amp. - Power Supply 2: 24VDC @ 9.7 amp. - Sixteen (16) fuse protected non power-limited outputs. Rev. DF022607

Table of Contents: Maxim Series Overview.................................................. 3 Maxim Series Configuration Chart......................................... 3 Maxim Series Features................................................. 3-4 Maxim Installation Instructions.......................................... 4-5 Maintenance......................................................... 5-6 Power Supply Board LED Diagnostics...................................... 6 Access Power Controller LED Diagnostics................................... 6 Power Supply Board Terminal Identification.................................. 6 Access Power Controller Terminal Identification.............................. 7 Power Supply Board Stand-by Battery Specifications.......................... 7 Power Supply Board Output Voltage Settings................................. 8 Access Power Controller Typical Application Diagram......................... 8 Maxim11, Maxim33 and Maxim55 Battery Hookup and Tamper Switch Installation.. 9 Maxim77 Battery Hookup and Tamper Switch Installation..................... 10 Maxim75 Battery Hookup and Tamper Switch Installation..................... 11 NEC Power-Limited Wiring Requirements for Maxim11.......................12 NEC Power-Limited Wiring Requirements for Maxim33 and Maxim55............13 NEC Power-Limited Wiring Requirements for Maxim77....................... 14 NEC Power-Limited Wiring Requirements for Maxim75....................... 15 FACP/Optional Power Supply Hook-up Diagrams............................ 16 Dimensions.................................................. 17-2 - Maxim11/Maxim33/Maxim55/Maxim75/Maxim77 Access Power Controllers (Fused)

Maxim Series Overview: Maxim Access Power/Controllers distribute and switch power to access control systems and accessories. They convert a 115VAC 60Hz input into sixteen (16) independently controlled 12VDC or 24VDC fuse protected outputs. These Fail- Safe/Fail-Secure power outputs may be converted to dry form C contacts. The outputs are activated by an open collector sink or normally open (NO) dry trigger input from an Access Control System, Keypad, Push Button, REX PIR, etc. Units will route power to a variety of access control hardware devices including: Mag Locks, Electric Strikes, Magnetic Door Holders, etc. The FACP Interface enables Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary devices. The fire alarm disconnect feature is individually selectable for any or all of the sixteen (16) outputs. All interconnecting equipment must be UL Listed. Altronix Model Number Maxim11 Maxim33 Power Supply 1 (8 outputs) Maxim Series Configuration Chart: Power Supply 2 (8 outputs) 12VDC @ 3.5 amp 12VDC @ 3.5 amp 7 amp 24VDC @ 2.7 amp 24VDC @ 2.7 amp 5.4 amp 12VDC @ 3.5 amp 24VDC @ 2.7 amp 6.2 amp 12VDC @ 5.5 amp 12VDC @ 5.5 amp 11 amp 24VDC @ 5.7 amp 24VDC @ 5.7 amp 11.4 amp 12VDC @ 5.5 amp 24VDC @ 5.7 amp 11.2 amp Total Output Current (16 outputs) 115VAC 60Hz Input (current draw) Fuse Protected Outputs Maximum Current Per ACM8 Output 16* 2.5 amp 4.5 amp 3.5A/250V 16 2.5 amp 7 amp 3.5A/250V Power Supply Board Input Fuse Rating UL Listings and File Numbers UL File # BP6714 UL 294 UL Listed for Access Control System Units. Maxim55 12VDC @ 9.5 amp 12VDC @ 9.5 amp 19 amp 16 2.5 amp 6 amp 3.5A/250V AL1012ULXB AL1024ULXB Maxim75 19.2 amp 16 2.5 amp 10 amp 3.5A/250V 12VDC @ 9.5 amp 24VDC @ 9.7 amp 10A/250V Maxim77 24VDC @ 9.7 amp 24VDC @ 9.7 amp 19.4 amp 16 2.5 amp 12.5 amp 10A/250V General Signaling Equipment Evaluated to CSA Standard C22.2 No.205-M1983 *Maxim11 outputs are power-limited. Maxim Series Features: Sixteen (16) independently trigger controlled outputs. Output options: a) Sixteen (16) Fail-Safe filtered and electronically regulated power outputs. b) Sixteen (16) Fail-Secure filtered and electronically regulated power outputs. c) Sixteen (16) form C relay outputs (rated @ 5 amp/28vdc or VAC). d) Any combination of the above. Sixteen (16) Access Control System trigger inputs. Input trigger options: a) Sixteen (16) normally open (NO) dry trigger inputs. b) Sixteen (16) open collector inputs. c) Any combination of the above. Sixteen (16) unswitched filtered and electronically regulated aux. power outputs (outputs are rated @ 2.5 amp). Red LEDs on ACM8 board indicate individual outputs are triggered (relays energized). Fire Alarm disconnect (latching or non-latching) is individually selectable for any or all of the sixteen (16) outputs. Fire Alarm disconnect input trigger options: a) Normally open (NO) or normally closed (NC) dry trigger input. b) Polarity reversal input from FACP signaling circuit. Green LED on ACM8 board indicates FACP disconnect is triggered. FACP output relay indicates that FACP input is triggered (form C contact rated @ 1 amp/28vdc not evaluated by UL). Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 3 -

Power supply input options: a) Factory installed power supplies provide common power for both ACM8 boards and all connected access control devices. b) An optional UL Listed power-limited external access control power supply may be connected to isolate the ACM8 boards from the access control devices (only applicable on Maxim11). ACM8 board main fuses are rated @ 10 amp. Output fuses are rated @ 2.5 amp. Built-in charger for sealed lead acid or gel type batteries. - Maximum charge current is 0.7 amp for AL400ULXB, AL600ULXB and AL1012ULXB power supply boards. - Maximum charge current is 3.6 amp for AL1024ULXB power supply board. Automatic switch over to stand-by battery when AC fails. Zero voltage drop when unit switches over to battery backup (AC failure condition). Short circuit and thermal overload protection with auto reset. Green AC input and red DC output LED indicators on power supply board(s). AC fail supervision (form "C" contact rated @ 1 amp/28vdc). Battery fail and battery presence supervision (form "C" contact rated @ 1 amp/28vdc). accommodates up to four (4) 12VDC/12AH batteries. dimensions: 26"H x 19"W x 6.25"D Maxim Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. Power Supply Board LED Diagnostics (pg. 6) Access Power Controller LED Diagnostics (pg. 6) Power Supply Board Terminal Identification (pg. 6) Access Power Controller Terminal Identification (pg. 7) Power Supply Board Stand-by Battery Specifications (pg. 7) Power Supply Board Output Voltage Settings (pg. 8) Access Power Controller Typical Application Diagram (pg. 8) FACP/Optional Power Supply Hook-up Diagrams (pg. 16) 1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws ( Dimensions, pg.17). 2. The power supply is pre-wired to the ground (chassis). Connect main incoming ground to the provided green grounding conductor lead. Connect unswitched AC power (115VAC 60Hz) to terminals marked [L, N] on both power supply boards. Use 14 AWG or larger for all power connections. Keep power-limited wiring separate from non power-limited wiring. Minimum.25 spacing must be provided (Figs. 6-9, pgs. 12-15). 3. Select desired DC output voltage by setting SW1 to the appropriate position on the power supply board (Maxim11 and Maxim33), (Fig. 1, pg. 8). Maxim55 power supply is factory set at 12VDC. Maxim77 power supply is factory set at 24VDC. Maxim75 consists of one (1) power supply board that is factory set at 12VDC, and one (1) power supply board that is factory set at 24VDC. 4. Measure the output voltage of the unit before connecting any devices to ensure proper operation. Improper or high voltage will damage these devices. 5. Output options (Fig. 2, pg. 8): The unit will provide either sixteen (16) switched power outputs, sixteen (16) dry form C outputs, or any combination of both switched power and form C outputs. (a) Fail-Safe Switched Power outputs: For Fail-Safe operation connect the positive (+) input of the access control devices to terminal marked [NC]. Connect the negative (-) input of the access control devices to terminal marked [COM]. (b) Fail-Secure Switched Power outputs: For Fail-Secure operation connect the positive (+) input of the access control devices to terminal marked [NO]. Connect the negative (-) input of the access control devices to terminal marked [COM]. (c) Form C outputs: When form C outputs are desired the corresponding output fuses (1-8) of each ACM8 board must be removed. - 4 - Maxim11/Maxim33/Maxim55/Maxim75/Maxim77 Access Power Controllers (Fused)

6. Auxiliary Power outputs (unswitched): Connect access control devices that require constant power to terminals marked [C] positive (+) and [COM] negative (-). 7. Input trigger options (Fig. 2, pg. 8): (a) Normally Open [NO] input trigger: Inputs 1-8 are activated by normally open or open collector sink inputs. Connect access control panel outputs, keypads, push buttons, REX PIRs, etc. to terminals marked [IN] and [GND]. (b) Open Collector Sink inputs: Connect the access control panel open collector sink positive (+) to terminals marked [IN] and the negative (-) to terminals marked [GND]. 8. Fire Alarm Interface options (Figs. 10-15, pg. 16): A normally closed [NC] or normally open [NO] input trigger from a fire alarm control panel or a polarity reversal input from an FACP signaling circuit will affect selected outputs. To enable FACP Disconnect for an output open the corresponding switch(es) [SW1-SW8] on each ACM8 board. To disable FACP disconnect for an output close the corresponding switch(es) [SW1-SW8] on each ACM8 board. (a) Normally Open [NO] input: For non-latching hook-up refer to (Fig. 12, pg. 16). For latching hook-up refer to (Fig. 13, pg. 16). (b) Normally Closed [NC] input: For non-latching hook-up refer to (Fig. 14, pg. 16). For latching hook-up refer to (Fig. 15, pg. 16). (c) FACP Signaling Circuit input trigger: Connect the positive (+) and negative (-) from the FACP signaling circuit output to the terminals marked [+ INP -]. Connect the FACP EOL to the terminals marked [+ RET -] (polarity is referenced in an alarm condition). Jumper J3 must be cut (Fig. 11, pg. 16). 9. FACP Dry form C output (Fig. 2A, pg. 8): FACP form C contacts can be use to trigger reporting or signaling devices. These contact switch upon a fire alarm input trigger to the ACM8 boards. 10. Stand-by Battery Connections (Figs. 3-5, pgs. 9-11): For Access Control applications batteries are optional. If batteries are not used a loss of AC will result in the loss of output voltage. Batteries must be lead acid or gel type. Connect one (1) 12VDC battery to the terminals marked [+ BAT -] for 12VDC operation (Figs. 3, 5, pgs. 9, 11). Use two (2) 12VDC batteries wired in series for 24VDC operation (Figs. 3-5, pgs. 9-11). 11. Battery and AC Supervision outputs (Figs. 3-5, pgs. 9-11): It is required to connect supervisory trouble reporting devices to outputs marked [AC Fail, BAT FAIL] supervisory relay outputs marked [NC, C, NO] to appropriate visual notification devices. Use 22 AWG to 18 AWG for AC Fail & Low/No Battery reporting. 12. Installation of tamper switch (Not Included) (Figs. 3A, 4A, 5A, pgs. 9-11): Mount UL Listed tamper switch (Sentrol model 3012 or equivalent) at the top of the enclosure. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side. Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 13. Multiple power supply inputs (Fig. 2, pg. 8): When using an additional UL Listed external power supply, jumpers J1 and J2 located on corresponding ACM8 boards must be cut (Fig. 2B, pg. 8 & Fig. 10, pg. 16). Connect external UL Listed power-limited access control power supply to the terminals marked [- Power +] (only applicable on Maxim11). When using DC power supplies polarity must be observed. When using AC power supplies polarity need not be observed. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute), (Fig. 6A-9A, pgs. 12-15). Maintenance: Unit should be tested at least once a year for the proper operation as follows: FACP Supervision: To insure proper connection and operation of the Fire Alarm disconnect hookup. Please follow the appropriate procedure below: Normally Open Input: Placing a short between terminals marked [T] and [+ INP] will trigger the Fire Alarm Disconnect. Remove the short to reset. Normally Closed Input: Remove the wire from terminal marked [INP --] will trigger the Fire Alarm Disconnect. Replace the wire to terminal marked [INP --] to reset. FACP Signal Circuit Input: It is necessary to trigger the Fire Alarm System. In all of the above scenarios the green TRG LED of the ACM8s will illuminate. All outputs selected for Fire Alarm Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 5 -

Disconnect will activate releasing locking devices. Note: All outputs [OUT 1 - OUT 8] must be in a normal (de-energized) condition prior to testing. When the unit is configured for Normally Open (Fig. 13, pg. 16) or Normally Closed (Fig. 15, pg. 16) latching operation it is necessary to reset the Fire Alarm Disconnect by activating the Normally Closed reset switch. Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level (Power Supply Board Stand-by Battery Specifications, pg. 7). Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage at the battery terminals and at the board terminals marked [+ BAT -] to insure that there is no break in the battery connection wires. Note: AL400ULXB, AL600ULXB and AL1012ULXB Power Supply Board maximum charge current is.7 amp. AL1024ULXB Power Supply Board maximum charge current is 3.6 amp. Expected battery life is 5 years, however it is recommended to change batteries within 4 years or less if necessary. LED Red (DC) Green (AC) Power Supply Status Power Supply Board LED Diagnostics: ON ON Normal operating condition. ON OFF Loss of AC, Stand-by battery supplying power. OFF ON No DC output. Short circuit or thermal overload condition. OFF OFF No DC output. Loss of AC. Discharged battery. Access Power Controller LED Diagnostics: LED ON OFF LED 1- LED 8 (Red) Output relay(s) energized. Output relay(s) de-energized. Trg (Green) FACP input triggered (alarm condition). FACP normal (non-alarm condition). Terminal Legend Function/Description Power Supply Board Terminal Identification: L, G, N Connect 115VAC 60Hz to these terminals: L to hot, N to neutral, G to ground. + DC - Maxim11-12VDC @ 3.5 amp or 24VDC @ 2.7 amp to ACM8 boards (power-limited). Maxim33-12VDC @ 5.5 amp or 24VDC @ 5.7 amp to ACM8 boards. Maxim55-12VDC @ 9.5 amp to ACM8 boards. Maxim77-24VDC @ 9.7 amp to ACM8 boards. Maxim75 - one (1) power supply which is 12VDC @ 9.5 amp to ACM8 board and one (1) power supply which is 24VDC @ 9.7 amp to ACM8 board. AC FAIL Indicates loss of AC power. To meet with UL requirements it is mandatory to connect visual notification NC, C, NO devices, connecting audible notification devices is optional. Relay normally energized when AC power is present. Contact rating 1 amp @ 28VDC. AC or brownout fail is reported within 1 minute of event. BAT FAIL Indicates low battery condition, e.g. connect to access control panel. Relay normally energized when NC, C, NO DC power is present. Contact rating 1 amp @ 28VDC. A removed battery is reported within 5 minutes. Battery reconnection is reported within 1 minute. Low battery threshold: 12VDC output threshold set @ approximately 10.5VDC. 24VDC output threshold set @ approximately 21VDC. + BAT - Stand-by battery connections. Connect one (1) 12VDC battery to the terminals marked [+ BAT -] for 12VDC operation (Fig. 3, pg. 9, Fig. 5, pg. 11). Use two (2) 12VDC batteries wired in series for 24VDC operation (Figs. 3-5, pgs. 9-11). - 6 - Maxim11/Maxim33/Maxim55/Maxim75/Maxim77 Access Power Controllers (Fused)

Terminal Legend Access Power Controller Terminal Identification: Function/Description - Control + 12VDC or 24VDC input from power supply board. - Power + These terminals can be connected to an external UL Listed power-limited access control (only applicable power supply to provide isolated operating power for the ACM8 (jumpers J1 and J2 Must be for Maxim11) removed). All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute), (Figs. 6A-9A, pgs. 12-15). TRIGGER From normally open and/or open collector sink trigger inputs INPUT 1- INPUT 8 (request to exit buttons, exit pir s, etc.). IN, GND OUTPUT 1-OUTPUT 8 12VDC to 24VDC trigger controlled outputs: NC, C, NO, COM Fail-Safe [NC positive (+) & COM Negative (-)], Fail-Secure [NO positive (+) & COM Negative (-)], Auxiliary output [C positive (+) & COM Negative (-)] (When using AC power supplies polarity need not be observed), NC, C, NO convert to dry form C 5 amp 24VAC/VDC rated dry outputs when fuses are removed. Contacts shown in a non-triggered state. FACP INTERFACE Fire Alarm Interface trigger input from FACP. Trigger inputs can be normally open, T, + INPUT -- normally closed from an FACP signaling circuit output (Figs. 10-15, pg. 16). FACP INTERFACE NC, C, NO Form C relay contact rated @ 1 amp 28VDC for alarm reporting (not evaluated by UL). Power Supply Board Stand-by Battery Specifications: Altronix Model Power Supply Board Battery 20 Min. of Backup 4 Hr. of Backup 24 Hr. of Backup Maxim11 AL400ULXB (Refer to Fig. 1A, pg. 8 for Switch [SW1] location and position) 12VDC/40AH* N/A 3.5 amp 0.5 amp 24VDC/40AH* N/A 2.7 amp 0.7 amp Maxim33 Maxim55 Maxim75 Maxim75 Maxim77 AL600ULXB (Refer to Fig. 1A, pg. 8 for Switch [SW1] location and position) AL1012ULXB (Factory set at 12VDC) AL1024ULXB (Factory set at 24VDC) AL1024ULXB (Factory set at 24VDC) 12VDC/40AH* N/A 5.5 amp 5.5 amp 24VDC/40AH* N/A 5.5 amp 0.7 amp 12VDC/12AH 9.0 amp Battery capacity for emergency standby at least 20 min N/A 24VDC/12AH 7.7 amp 1.2 amp N/A 24VDC/65AH* N/A 7.7 amp 1.2 amp * Note: Additional battery enclosure required (Figs. 6-9, pg, 12-15) Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 7 -

Power Supply Board Output Voltage Settings: Fig. 1 Fig. 1A RL3 24V - OPEN 12V - CLOSED SW1 + BAT --- SW1 Switch Detail OPEN SWITCH 24V - OPEN 12V - CLOSEDSW1 AC + BAT --- DC AC Delay CLOSED SWITCH NO NC C NO AC FAIL Maxim11 - Power Supply Board BAT FAIL NC C NO NC C NO AC FAIL Maxim33 - Power Supply Board Access Power Controller Typical Application Diagram (for each ACM8): Fig. 2 ACCESS CONTROL PANEL OUTPUT RELAY C NO NC F1 IN GND 1 IN GND 2 IN GND IN GND 3 4 PUSH BUTTON IN GND 5 IN GND 6 IN GND 7 IN GND 8 KEYPAD F2 F3 F4 F5 F6 F7 F8 SW5 TRG FACP (Fire Alarm Control Panel) J3 + INP --- T + RET - + --- FACP INTERFACE Fig. 2A FACP Dry Form "C" Output FACP SW1-SW8 FACP Interface Enabled LED1 SW1 SW2 SW3 SW4 SW6 SW7 SW8 LED2 LED3 LED4 LED5 LED6 LED7 LED8 10A 250V MAIN FACP Interface Disabled MAG. LOCK NC C NO COM OUTPUT 1 NC C NO COM OUTPUT 2 NC C NO COM OUTPUT 3 NC C NO COM OUTPUT 4 NC C NO COM OUTPUT 5 NC C NO COM OUTPUT 6 NC C NO COM OUTPUT 7 NC C NO COM OUTPUT 8 J2 J1 --- + Control --- + Power INTERNAL DC POWER SUPPLY (CONNECTED) ELECTRIC STRIKE ELECTROMAGNETIC DOOR HOLDERS For this application corresponding fuse F8 must be removed. This procedure makes the output a dry contact. MAG. LOCK J2 J1 Fig. 2B EXTERNAL UL LISTED POWER SUPPLY (Only applicable on Maxim11) - 8 - Maxim11/Maxim33/Maxim55/Maxim75/Maxim77 Access Power Controllers (Fused)

Fig. 3 Maxim11 Maxim33 Maxim55 Tamper Switch Power Supply Board + DC --- + BAT --- Line L G N Ground Neutral BAT FAIL NC C NO NC C NO AC FAIL Ground Lug Wire Strap (from to Door) Power Supply Board + DC --- + BAT --- 115VAC Input 60 Hz. Ground L G N Line Ground Ground Lug Neutral BAT FAIL NC C NO NC C NO AC FAIL Optional 12VDC Battery** Optional 12VDC Battery** *12VDC operation: For 12VDC operation only a single battery is needed. Connect red battery lead to terminal marked [+ BAT] and to the [positive (+)] terminal of the battery. Connect black battery lead to terminal marked [BAT -] and to the [negative (-)] terminal of the battery. Optional 12VDC Battery* **24VDC operation: Connect two (2) 12VDC batteries in series Fig. 3A Sentrol model # 3012 Tamper Switch or equivalent (Not Included) Edge of to Access Control Panel or U.L. Listed Reporting Device Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 9 -

Fig. 4 Maxim77 Tamper Switch AC FAIL BAT FAIL Power Supply Board L G N Line Ground Neutral + BAT --- --- DC + Ground Lug AC FAIL BAT FAIL Wire Strap (from to Door) Power Supply Board 115VAC Input 60 Hz. Ground L G N Line Ground Neutral Ground Lug + BAT --- --- DC + Optional 12VDC Battery** Optional 12VDC Battery** Optional 12VDC Battery** Optional 12VDC Battery** **24VDC operation: Connect two (2) 12VDC batteries in series Fig. 4A Sentrol model # 3012 Tamper Switch or equivalent (Not Included) Edge of to Access Control Panel or U.L. Listed Reporting Device - 10 - Maxim11/Maxim33/Maxim55/Maxim75/Maxim77 Access Power Controllers (Fused)

Fig. 5 Maxim75 Tamper Switch Power Supply Board + BAT --- + DC --- L G N Line Ground Neutral BAT FAIL NC C NO NC C NO AC FAIL Ground Lug AC FAIL BAT FAIL Wire Strap (from to Door) Power Supply Board 115VAC Input 60 Hz. Ground L G N Line Ground Neutral Ground Lug + BAT --- --- DC + Optional 12VDC Battery** Optional 12VDC Battery** *12VDC operation: For 12VDC operation only a single battery is needed. Connect red battery lead to terminal marked [+ BAT] and to the [positive (+)] terminal of the battery. Connect black battery lead to terminal marked [BAT -] and to the [negative (-)] terminal of the battery. Optional 12VDC Battery* **24VDC operation: Connect two (2) 12VDC batteries in series Fig. 5A Sentrol model # 3012 Tamper Switch or equivalent (Not Included) Edge of to Access Control Panel or U.L. Listed Reporting Device Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 11 -

NEC Power-Limited Wiring Requirements for Maxim11: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power-limited applications, use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire, (Fig. 6A). Fig. 6 External UL Listed Power-Limited, Access Control Power Supply 12 to 24VAC or DC Optional Battery Supervisory Connections (power-limited) 115VAC Input 60Hz ACM8 outputs (powerlimited) Fig. 6A Incorrect Wire Handling Correct Wire Handling External Jacketed Shield Battery Connections Wire Insulation Solid Copper Conductors Pull back external jacketed shield approximately 1/2. - 12 - Maxim11/Maxim33/Maxim55/Maxim75/Maxim77 Access Power Controllers (Fused)

NEC Power-Limited Wiring Requirements for Maxim33 and Maxim55: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power-limited applications, use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire, (Fig. 7A). Fig. 7 Optional Battery Supervisory Connections (power-limited) 115VAC Input 60Hz ACM8 outputs (non powerlimited) Fig.7A Incorrect Wire Handling External Jacketed Shield Battery Connections Correct Wire Handling Wire Insulation Solid Copper Conductors Pull back external jacketed shield approximately 1/2. Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 13 -

NEC Power-Limited Wiring Requirements for Maxim77: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power-limited applications, use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire, (Fig. 8A). Fig. 8 Optional Battery Supervisory Connections (power-limited) 115VAC Input 60Hz ACM8 outputs (non powerlimited) Fig. 8A Incorrect Wire Handling External Jacketed Shield Battery Connections Correct Wire Handling Wire Insulation Solid Copper Conductors Pull back external jacketed shield approximately 1/2. - 14 - Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused)

NEC Power-Limited Wiring Requirements for Maxim75: Power-limited and non power-limited circuit wiring must remain separated in the cabinet. All power-limited circuit wiring must remain at least 0.25 away from any non power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non power-limited circuit wiring must enter and exit the cabinet through different conduits. One such example of this is shown below. Your specific application may require different conduit knockouts to be used. Any conduit knockouts may be used. For power-limited applications, use of conduit is optional. All field wiring connections must be made employing suitable gauge CM or FPL jacketed wire (or equivalent substitute). Note: Refer to wire handling drawing below for the proper way to install the CM or FPL jacketed wire, (Fig. 9A). Fig. 9 Optional Battery Supervisory Connections (power-limited) 115VAC Input 60Hz ACM8 outputs (non powerlimited) Fig. 9A Incorrect Wire Handling External Jacketed Shield Battery Connections Correct Wire Handling Wire Insulation Solid Copper Conductors Pull back external jacketed shield approximately 1/2. Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 15 -

FACP/Optional Power Supply Hook-up Diagrams: Fig. 10 Optional hook-up using two (2) isolated power supply inputs (Only applicable on Maxim11): CUT JUMPERS J1 AND J2 Fig. 11 Polarity reversal input from FACP signaling circuit output (polarity is referenced in alarm condition): CUT JUMPER J3 ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (ACM8 POWER) ISOLATED POWER INPUT 12 OR 24 VAC OR VDC (LOCK POWER) FACP INTERFACE FACP SIGNAL CIRCUIT OUTPUT EOL -- + FROM FACP SIGNAL OUTPUT CIRCUIT Fig. 12 Normally Open - Non-Latching FACP trigger input: Fig. 13 Normally Open FACP Latching trigger input with reset: (This output has not been evaluated by UL) FACP INTERFACE N.O. TRIGGER INPUT N.O. TRIGGER INPUT JUMPER N.C. RESET SWITCH Fig. 14 Normally Closed - Non-Latching FACP trigger input: Fig. 15 Normally Closed - Latching FACP trigger input with reset: (This output has not been evaluated by UL) FACP INTERFACE JUMPER N.C. DRY TRIGGER INPUT JUMPER N.C. RESET SWITCH N.C. TRIGGER INPUT - 16 - Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused)

Dimensions: 26"H x 19"W x 6.25"D 1 7" 2.00" 4.00" 7.00" 4.00" 2.00" TOP 6.25" 1 7" 1.25" 0.85" 8.90" 8.40" 0.85" 1.25" 1.50" 1.50" 1.50" 5.00" 8.50" 7.00" 7.50" 7.50" 2 2" 2 2" 8 5" 2 2" LEFT RIGHT 10.0" 7.00" 1.00" 0.85" 8.90" 8.40" 1.00" 0.85" 1.25" 2.00" BOTTOM 6.25" 1 7" 4.00" 2.00" Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 17 -

Notes: - 18 - Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused)

Notes: Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused) - 19 -

Notes: Altronix is not responsible for any typographical errors. Altronix Corp. 140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056 web site: www.altronix.com, e-mail: info@altronix.com, Lifetime Warranty, Made in U.S.A. IIMaxim11/33/55/75/77 Series A31H MEMBER - 20 - Maxim11/Maxim33/Maxim55/Maxim77/Maxim75 Access Power Controllers (Fused)