GL2.5 Ti GL4Ti GL8Ti

Similar documents
Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+


Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Seaward Products OWNER S MANUAL WATER HEATERS. Serial Number:

SAVE THESE INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

SHC 2.5 MINI-TANK ELECTRIC WATER HEATERS CALENTADORES DE AGUA ELÉCTRICOS DE MINI-TANQUE CHAUFFE-EAU ÉLECTRIQUES À MINI-RÉSERVOIR

GEOTHERMAL STORAGE TANKS

INSTALLATION & SERVICE MANUAL

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

TORRID MARINE YACHT QUALITY Since Owner s Manual

INSTANT-FLOW C-MICRO WATER HEATER

Point-of-Use Water Heater Owner s Manual. Installation, Care & Use

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

INSTANT-FLOW C-MICRO WATER HEATER

Internet Version for Reference Only STORAGE UNIT

Installation Manual. Models 99168, 99169, 99170

VP17A BUNN OPERATING & SERVICE MANUAL

INSTALLATION OPERATION MAINTENANCE

COMMERCIAL ELECTRIC WATER HEATER OWNER S MANUAL OPERATION AND MAINTENANCE INSTRUCTIONS

TWO GALLON ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Viking Installation Guide

Installation and Operating Instructions

Operating & Safety Instructions

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

INSTALLATION & OPERATING INSTRUCTION MANUAL

FLCH4R Garage and Utility Electric Heater

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

OPERATING AND INSTALLATION MANUAL

B.I.C.A Built-In Coffee Appliance

Installation and Operation Guide

OPERATING AND INSTALLATION MANUAL

IMPORTANT SAFETY INFORMATION:

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMPACT POINT-OF-USE ELECTRIC WATER HEATER

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

Comfort Series Instant Hot Water System

Installation Instructions / Warranty

harborbreezeoutlet.com

MaxLite LED Round Pendant Highbay Series

H 2. Hot Water Storage/ Booster Tanks. For Single Tank Installations INSTALLATION, OPERATION & MAINTENANCE MANUAL

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

HI Industrial Utility Heater HI Soleus Air International

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

Sun Bandit Hybrid Water Heater Installation and Operation Solar Hybrid Energy Systems Patent(s) Pending

OPERATION AND INSTALLATION

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

INSTRUCTIONS FOR OPERATION AND CARE OF

TABLE 1 Electrical Specifications

IMPORTANT SAFETY INFORMATION:

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Spa Control System OWNER S MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

TABLE 1 Electrical Specifications. Phase

COMMERCIAL ELECTRIC WATER HEATER INSTALLATION & OPERATION INSTRUCTION MANUAL

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

METS MODEL E-106. (115 VAC, 60 Hz) USER S MANUAL INSTALLATION OPERATION MAINTENANCE

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Flow Factor ~

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Seaward Products. OWNER S MANUAL Installation Operation - Maintenance. Princess Gourmet Model 345. Built-in Electric Oven ELECTRIC WALL OVEN

e Bath Fan with Light User s Guide

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

gamma pond Ultraviolet Sterilizers

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

INSTALLATION AND SERVICE MANUAL

Lifetime Limited Warranty

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

e Heater/Exhaust Fan/Light User s Guide

Wilbur Curtis Company, Inc.

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

BUNN H5E H5M H5X BUNN-O-MATIC CORPORATION POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS PHONE: (217) FAX: (217)

Steam Bug. World's smallest steam iron great for travel

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4-5. Replacement Element Installation 5. Replacement Parts 5-6

LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

VENTILATION FAN / LED LIGHT

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

O w n e r s M a n u a l

Peerless Partner PV Series Indirect Fired Water Heater

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Installation Guide. For Models: E-MLV36BNK4LK1 E-MLV36ESP4LK1 E-MLV36WW4LK1 READ THESE INSTRUCTIONS AND AND SAVE THEM FOR FUTURE USE

CONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION

Whole House Filter Model: WH-LD

Transcription:

mini-tank electric water heaters chauffe-eau électriques à miniréservoir calentadores de agua eléctricos de minitanque Meets ASHRAE 90.1 standard INSTALLATION MANUAL FOR DIRECTIVES D INSTALLATION POUR INSTRUCCIONES DE SEGURIDAD IMPORTANTES GL2.5 Ti GL4Ti GL8Ti CONTROLLED ENERGY CORPORATION 340 Mad River Park Waitsfield, Vermont 05673 800-798-8161 www.protankless.com

IMPORTANT SAFETY INSTRUCTIONS WARNING When using electrical appliances, safety precautions to reduce the risk of fire, electric shock or injury to persons should be followed, including: 1. READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER. 2. This water heater must be grounded. Connect only to properly grounded outlet. See GROUNDING INSTRUCTIONS found on INSTALLATION INSTRUCTIONS. 3. Install or locate this water heater only in accordance with the provided installation instructions. 4. Use this water heater only for its intended use as described in this manual. 5. Do not use an extension cord set with this water heater. If no outlet is available adjacent to the water heater, contact a qualified electrician to have one properly installed. 6. As with any appliance, close supervision is necessary when used by children. 7. Do not operate this water heater if it is not working properly or if it has been damaged or dropped. 8. This water heater should be serviced only by qualified service personnel. Contact a service person for examination, repair or adjustment. 9. Failure to service the anode rod at least once a year could cause the tank to fail and leak. Any water heater should be installed in such a manner that if it should leak, the resulting flow of water will not cause damage to the area in which it is installed. National Plumbing codes require a drain pan for any water heater installation. Failure to install one is the sole responsibility of owner and/or installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510 - Protection from Damage or IPC 200 (International Plumbing Code) Section 504- Safety Devices. KEEP THESE INSTRUCTIONS AT HAND SAVE THESE INSTRUCTIONS Technical data MODEL GL 2.5 Ti GL 4 Ti GL 8 Ti Capacity gallons 2.75 3.85 7.0 Voltage Vac 110/120 for each model Power at 120 Vac Watts 1500 1500 1500 Maximum Water pressure psi 150 150 150 Weight Lbs 15.5 17.3 29.5 Amperage Amps 12.50 for each model Phases 1 1 1 WARNING The installer should review the contents of this manual with the owner upon completion of installation, and the manual should be left with the owner and placed in a location close to the installation. 1

FIG. 1/1 Hot water outlet 1/2 NPT male Temperature & pressure relief valve, 3/4 NPT male Cold water inlet 1/2 NPT male 3/4 NPT female tapping for relief valve Temperature & pressure relief valve discharge line to drain COMPONENT PARTS OF GL 2.5Ti - 4Ti FIG. 1/2 Temperature & pressure relief valve, 3/4 NPT male COMPONENT PARTS OF GL 8Ti (Horizontal installation) Hot water outlet 3/4 NPT male 3/4 NPT female tapping for relief valve 3/4 NPT male plug Temperature & pressure relief valve discharge line to drain 3/4 NPT female tapping Cold water inlet 3/4 NPT male FIG. 1/3 Hot water outlet 3/4 NPT male Temperature & pressure relief valve, 3/4 NPT male Cold water inlet 3/4 NPT male COMPONENT PARTS OF GL 8Ti (Vertical installation) 3/4 NPT female tapping for relief valve Temperature & pressure relief valve discharge line to drain 3/4 NPT male plug 3/4 NPT female tapping 2

FIG. 2/1 1 14 3 3/4 DIMENSIONS FOR GL 2.5Ti - GL 4Ti 10 1/4 12 1/4 6 GL 2.5 7 1/2 1/2 NPT MALE 3 1/2 3 5 1/2 2 1/2 14 GL 4 FIG. 2/2 DIMENSIONS FOR GL 8Ti (HORIZONTAL INSTALLATION) 14 1/2 8 1/2 4 1/2 3/4 NPT MALE 17 1/2 FIG. 2/3 DIMENSIONS FOR GL 8 Ti (VERTICAL INSTALLATION) 11 1/2 14 1/2 8 1/2 4 1/2 17 1/2 3 17 1/2 11 1/2 3/4 NPT MALE 1 6 1/2 2 1/2 17 1/2 3

General remarks CAUTION CAUTION CAUTION The manufacturer cannot be responsible for the damages caused by improper installation or by failure to follow instructions in this pamphlet. Comply with the installation instructions before completing electric connection. The thermostat has been pre-set at the factory at or below 51.7 C (125 F). Hydrogen gas can be produced in a hot water system served by this heater that has not been used for a long period of time (generally 2 weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these conditions, it is recommended that the hot water faucet be opened for several minutes before using any electrical appliance connected to the hot water system. If hydrogen gas is present, there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow. There should be no smoking or open flame near the faucet at this time. CAUTION Any water heater should be installed in such a manner that if it should leak, the resulting flow of water will not cause damage to the area in which it is installed. National Plumbing codes require a drain pan for any water heater installation. Failure to install one is the sole responsibility of owner and/or installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510- Protection from Damage or IPC 2000 (International Plumbing Code) Section 504- Safety Devices. Installation instructions MODEL GL 8Ti Wall mounting (only for vertical installation) Floor Mounting Wiring and Grounding instructions The GL 8Ti water heater can be installed under the sink. Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall material and the weight of the heater. Hang the water heater on the bracket. Tug down wards on the heater to ensure that both fingers of the bracket are seated in the mounting slots. Confirm water piping orientation before wall mounting. Wall bracket will not support the GL8Ti when the plumbing connections are installed horizontally. Heater can sit on floor. Confirm water piping orientation before locating on floor location. As per the National Electric Code the GL8Ti needs to be wired with 12 GA. wire to a minimum 20 amp/ maximum 20 amp branch circuit. To wire the GL8Ti model: 1. Pry off the round cover plate (V Fig. 3/1) from its right hand edge (W Fig. 3/1) with a small flat-head screwdriver. 2. Remove the Phillips screw revealed beneath the round cover plate. 3. The cover (C Fig. 3/1) can now be removed by pulling out its left-hand edge. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot. 4. Insert 12 AWG through conduit at rear of heater. Secure internal wire connector (A Fig. 3/2) and connect wiring to right side of thermostat control and ground. Positive (+) to lower terminal marked L (E Fig. 3/2) and Neutral to upper terminal marked N (H Fig. 3/2). Unit must be grounded at groundscrew (T Fig. 3/2) on element base. 5. When the GL8Ti is not within sight of the electrical circuit breakers, a circuit breaker lockout or additional local means of disconnection for all non grounded conductors must be provided that is within sight of the appliance. [REF NEC 422.31] Pipe connections 4 Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring). The model GL8Ti can be piped horizontally from the side or vertically from the top. If you wish to install the unit horizontally, with the piping connections on the right side, you will have to be certain the tap between the two water tappings is plugged, the supplied Temperature and Pressure Relief Valve will need to be installed on top. See location of T&P relief valve in Fig. 2/2.

If you wish to install the unit vertically, with the piping connections on top, you will have to be certain the tap on the side is plugged, the supplied Temperature and Pressure Relief Valve will need to be installed on top. See location of T&P relief valve in Fig. 2/3. FIG. 3/1 V C W F FIG. 3/2 Z G H F E X Y T A MODEL GL 2.5Ti - GL 4Ti The GL 2.5Ti and GL 4Ti water heaters can be installed under the sink. Wall mounting Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall material and the weight of the heater. Hang the water heater on the bracket. Tug down wards on the heater to ensure that both fingers of the bracket are seated in the mounting slots. 5

Floor Mounting Pipe connections CAUTION Heater can sit on floor. Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring) and the hot water outlet pipe to the outlet nipple (marked with a red ring). To reduce the risk of excessive pressures and temperatures in this water heater, install the supplied temperature and pressure protective equipment required by local codes but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials, as meeting the requirements for Relief Valves and Automatic Gas Shut-off Devices for Hot Water Supply Systems, ANSI Z21.22. The supplied temperature and pressure relief valve is marked with a maximum set pressure (150 psi) that does not exceed the marked maximum working pressure of the water heater. Install the valve in the opening provided and marked for this purpose in the water heater, and orient it or provide tubing so that any discharge from the valve will exit within 6 inches above, or at any distance below, the structural floor, and cannot contact any live electrical part. The discharge opening must not be blocked or reduced in size under any circumstances. National Plumbing codes require a drain pan for any water heater installation. Failure to install one is the sole responsibility of owner and/or installer. Reference UPC 2000 (Uniform Plumbing Code) Section 510- Protection from Damage or IPC 2000 (International Plumbing Code) Section 504- Safety Devices. Closed system thermal expansion (for all models) Periodic discharge of the temperature and pressure relief valve or failure of the element gasket may be due to thermal expansion in a closed water supply system. The water utility supply meter may contain a check valve, backflow preventer or water pressure reducing valve which will create a closed water system. During the heating cycle of the water heater, the water expands causing pressure inside the water heater to increase. The temperature and pressure relief valve may discharge hot water under these conditions which results in a loss of energy and a build-up of lime on the relief valve seat. To prevent this from happening, there are two recommendations: 1. Install a diaphragm-type expansion tank that is suitable for potable water on the cold water supply line. The expansion tank must have a minimum capacity of 1.5 U.S. gallons for every 50 gallons of stored water. 2. Install a 125 PSI pressure relief valve in the cold water supply line. Make sure the discharge of this valve is directed to an open drain and protected from freezing. Contact the local water supplier or plumbing inspector for information on how to control this situation. Do not plug the temperature and pressure relief valve. Instructions for use Starting and testing Before connecting the power, fill the tank and system with water and check for leaks. To be certain that all air is out of the water system, open the hot water faucets on your fixtures until constant water flows from them, otherwise damage to the element may occur. To start the heating cycle: A) first make sure tank is full. Otherwise the heating element may be damaged. B) the red light will come on and remain on until that temperature has been reached, at which point the light will go off, but will automatically come back on when the water temperature drops below the setting chosen. Temperature Setting After installation check the water temperature. If adjustment is necessary, remove front cover to adjust thermostat (D Fig. 4 -clockwise to increase the temperature and counter clockwise to decrease it). To reach the thermostat: 1. Pry off the round cover plate (V Fig. 3/1) from its right hand edge (W Fig. 3/1) with a small flat-head screwdriver. 2. Remove the Phillips screw revealed beneath the round cover plate. 6

3. The cover (C Fig. 3/1) can now be removed by pulling out its left-hand edge. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot. FIG. 4 B D Maintenance instructions Note: Periodic maintenance Note: Do not attempt to repair this water heater yourself. Call a service person for assistance. Always turn off the power supply to the heater prior to servicing or draining the heater. For most of these operations, the water will have to be drained from the heater. For all of these operations the power supply needs to be shut off and the front cover removed. 1. Pry off the round cover plate (V Fig. 3/1) from its right hand edge (W Fig. 3/1) with a small flat-head screwdriver. 2. Remove the Phillips screw revealed beneath the round cover plate. 3. The cover (C Fig. 3/1) can now be removed by pulling out its left-hand edge. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot. Draining the Heater 1) If the heater has been installed with flexible hoses, shut off the power supply and turn the heater upside down over a sink to drain the water out of it, OR 2) If the heater has been installed with rigid piping, siphon the water out through any (lower) service valve on the (inlet side). Keep a hot water faucet open while siphoning the water out, OR 3) If the heater has been installed with flexible hoses, it can also be emptied by siphoning through the inlet side hose. Keep a hot water faucet open while siphoning. 7

Removing the heating element 1. Turn off power supply and drain the heater (see previous section). 2. Remove the front cover plate, disconnect terminals X, Y and T (fig. 3/2). 3. Unscrew the 4 heating element retaining nuts F (fig. 3/2). 4. Remove the element. G (fig. 5/1). FIG. 5/1 N G FIG. 5/2 Descaling the heating element Scale deposits can affect the heating capability of the element. Heavy scale can even cause the element to burn out. The element can be descaled either chemically or manually: A) Soak the element in white vinegar or other descaling solution. Once descaled, rinse well with fresh water, to which you should add some baking soda, OR B) Once the element has dried up, use a soft brush (non metallic to prevent damaging the stainless steel sheath) on element. Brush the dried mineral off. Reinstall the element with gasket and make the wire connections. C) Replace anode rod (N Fig. 5/2) if it is noticeably deteriorated or considerably shorter then seen in figure 5/2. WARNING: make sure the tank has been refilled with water before restoring power. REPLACEMENT OF PARTS Changing the anode rod The anode rod (N fig. 5/2) helps protect the tank against corrosion. Depending on the water condition, the magnesium anode rod may need to be changed every year or so. Galvanic and electrolytic corrosion can destroy a tank if the anode rod is spent. Rusty water is usually an indication of a spent anode rod. If rusty water is present, examine anode rod immediately. Rapid degradation of the anode rod (less than 1 year) may indicate the presence of galvanic corrosion due to stray direct current. In this case, it may be necessary to add a grounding strap from the Ariston tank to the copper plumbing. 1. Turn off the power supply and drain the heater (see Draining the Heater). 2. Remove heating element (see previous section). 3. Remove and replace the anode rod N Fig. 5/2. 4. Refill tank with water before restoring power. 8

Changing the heating element Changing the thermostat Resetting High Limit Switch 1. Turn off power supply and drain the heater (see Draining the Heater). 2. Remove the heating element (see section on Removing the Heating Element). 3. Install new element with gasket, making sure the gasket and element are positioned correctly. Tighten the retaining nuts and make the wire connections. 4. Refill tank with water before restoring power. 1. Turn off power supply. 2. Disconnect the 2 push/pull type wires on thermostat. 3. Loosen the two brass screws at right side of thermostat and pull wires out. 4. Unscrew and remove the two phillips screws holding the thermostat down. 5. Install new thermostat and re-attach wiring and screws. Occasionally, the high temperature limit shut off device may trigger and shut the system down. This occurs when water temperature exceeds 190 F and shuts off power to the heating element. The shut off device may also trigger from a power outage or electrical storm. Troubleshooting Water does not get hot To reach the thermostat: 1. Pry off the round cover plate (V Fig. 3/1) from its right hand edge (W Fig. 3/1) with a small flat-head screwdriver. 2. Remove the Phillips screw revealed beneath the round cover plate. 3. The cover (C Fig. 3/1) can now be removed by pulling out its left-hand edge. When reassembling, work in the opposite way being careful to insert the tongue of the cover into the slot. 4. Firmly press reset button (B Fig. 4). Reconnect power. 5. IMPORTANT: Check the operation of the thermostat, turn temperature dial from high to low, if the red light does not go off on low setting, turn off power supply and call a service person to replace the thermostat. 6. If the system works, place dial setting to desired setting. Note: a lower setting is more economical and reduces the risk of scalding. Replace cover plate. CAUTION: Call a technician if the high limit needs to be reset frequently. 1. Make sure the power supply is on and working. 2. If light does not come on, check that the reset button is pushed in; follow steps from previous section. 3. If the indicator light works properly but temperature does not get hot a tap, test for a plumbing crossover; shut off cold supply to heater and open hot water tap. There should be no water flowing. Any continued flow indicates a crossover which will effect the temperature and will need to be corrected. 4. Replace heating element (see previous section on changing the heating element). Light not on Brown water Odor in water Water is too hot 1. If the light does not come on, but water gets hot, check for faulty bulb. 2. Check reset button; follow steps from previous section. 1. Brown or rusty water indicates a spent anode rod. Replace anode rod. 1. Smelly water could be due to an unusual reaction between local water and the heater s anode rod. Check anode rod (see section on changing the anode rod). 1. Remove cover plate and turn the temperature selector dial (D Fig. 4) counter clockwise to lower temperature. If temperature never lowers then replace thermostat. (see section on changing the thermostat). Water not hot enough Leaking 1. Adjust the temperature selector dial (D Fig. 4) clockwise to increase temperature. 1. Check water fittings and T & P fitting on top of tank. 2. Remove front cover and inspect heating element gasket. 9

DESCRIPTION REF. GL 2.5Ti A GL 4Ti B GL 8Ti C PART CODE DESCRIPTION REF. 1 100XL VALVE (T&P 3/4 ) ABC 2 570241 ANODE (MAGNESIUM) C 2 574305 ANODE (MAGNESIUM) AB 3 994147 GASKET WITH 4 BOLTS ABC 4 994140 LOCK NUT M6 ABC 5 994103 HEATING ELEMENT (1500/120) AB 5 994104 HEATING ELEMENT (1500/120) C 6 PLASTIC COVER RETAINING SCREW 7 NAME BADGE (PLASTIC) 8 COVER 9 SWITCH COVER 10 THERMOSTAT WIRING 11 994062 THERMOSTAT AB 11 994102 THERMOSTAT C 12 CABLE CLAMP 13 SUPPLY CABLE AB 14 570341 HEATER WALL HANGING BRACKET ABC 15 gl6plug 3/4 BRASS PLUG (GL6 ONLY) C ARISTON INTERIOR COMPONENTS DIAGRAM GL 2.5Ti, 4Ti, 8Ti 10

ARISTON GLTi LIMITED 8 YEARS WARRANTY COVERAGE ARISTON, THROUGH ITS U.S. DISTRIBUTOR CONTROLLED ENERGY CORP., (hereinafter CEC) guarantees this water heater to the Owner (hereinafter Owner ) of the water heater at the original installation location against defects in material and workmanship for the periods specified below. WARRANTY PERIOD 1. The inner Tank - If the inner tank leaks within eight (8) years from the date of original installation of the water heater, because of a defect in material or workmanship, CEC will furnish to such Owner a new heater of the then prevailing comparable model. 2. Any Component Part Other than The Original Inner Tank - If any component part (other than the inner tank) proven to be defective in material or workmanship within one (1) year from the date of original installation of the water heater, CEC will furnish the Owner with a replacement of the defective part(s). 3. Verification of Date of Original Installation - When Owner cannot verify or document the original date of installation, the warranty period begins on the date of manufacture marked on the tag affixed to the water heater. EXCLUSIONS 1. THIS LIMITED WARRANTY SHALL BE THE EXCLUSIVE WARRANTY MADE BY THE MANUFACTURER AND IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED (WHETHER WRITTEN OR ORAL), INCLUDING, BUT NOT LIMITED TO, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 2. The Manufacturer shall not be liable for any incidental, consequential, special or contingent damages or expenses arising, directly or indirectly, from any defect in the water heater or the use of the water heater. supplied with potable water. 5. The OWNER and not the Manufacturer or his representative shall be liable for and shall pay for all field charges for labor or other expenses incurred in the removal and/or repair of the product or any expense incurred by the owner in order to repair the product. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH MAY VARY FROM STATE TO STATE. IMPORTANT: OWNER SHALL KEEP THIS MAKE A CLAIM NOTE: A water heater should be installed in such a manner that if it should leak, the resulting flow of water will not cause damage to the area in which it is installed. HOW THE OWNER CAN SECURE SERVICE OR MAKE A CLAIM 1. Owner should contact the dealer who sold the water heater covered by this warranty or 2. Owner should submit the warranty claim directly to CEC at the address listed below, and they will arrange for the handling of the claim 3. Whenever any inquiry or service request is made, be sure to include the water heater model number the date of manufacture, date of installation, Dealer s name and the watts and voltage. 4. When returning the water heater or component part(s), they must be individually tagged and identified with the Returned Goods Authorization # issued by CEC and shipped prepaid to CEC at the address below. 3. The Manufacturer shall not be liable for any water damage arising, directly or indirectly, from any defect in the water heater component part(s) or from its use. 4. Manufacturer shall not be liable under this warranty if: a) The water heater or any of its component parts has been subject to misuse, alteration, neglect or accident, or b) The water heater has not been installed in accordance with the applicable local plumbing and/or building code(s) and/or regulation(s), or c) The water heater has not been installed in accordance with the printed manufacturer s instructions, or d) The water heater is not continuously Controlled Energy Corp. 340 Mad River Park Waitsfield, VT 05673 800-798-8161 www.protankless.com/tech

MTS MAKES USE OF RECYCLED PAPER Merloni TermoSanitari SpA Viale Aristide Merloni, 45 60044 Fabriano (AN) Tel. 0732.6011 Telefax. 0732.602331 http://www.mtsgroup.com E-mail: marketing@it.mtsgroup.com Controlled Energy Corp. 340 Mad River Park Waitsfield, VT 05673 800-798-8161 www.protankless.com/tech 029.1.60.435.2.00 0604 Litograf s.r.l. Jesi