NGD8800 USER S MANUAL

Similar documents
6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

Refrigerant Leak Detector

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

99 Washington Street Melrose, MA Phone Toll Free Visit us at

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

CD100A COMBUSTIBLE GAS DETECTOR

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

TEK-Mate. Refrigerant Leak Detector

TEK-Mate. Refrigerant Leak Detector

CLI Refrigerant Gas Leak Detector. User s Guide

Instruction Manual MSI Sensit HXG

LS1. Operator Manual. Kane International Ltd

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Red Alarm Indicator Light

COMBUSTIBLE GAS LEAK DETECTOR PEN

Combustible Gas Leak Detector Instruction Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

GAS-Mate. Combustible Gas Leak Detector

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

Installation and Wiring 1.

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

testo 316-EX gas leak detector Instruction manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

INSTRUCTION MANUAL CD Fax: (503)

ALTAIR 5X Multigas Detector Product Specification

Model: LD5 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

SENSIT HXG-2d Combustible Gas Detector

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Combustible Gas Leak Detector Instruction Manual

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

T.ex Single Gas Detector VISA

We measure it. testo 316-Ex CH 4 testo 316-1

GERMANY TEC 'LOGY leak-detect EXPERT

SP-220. Features. Combustible handheld gas leakage detector

Combustible Gas Detection and Control System

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

USER MANUAL MINITRACER PORTABLE SNIFFER

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

CO warning instruments and gas spillage detectors

LD-5000 REFRIGERANT LEAK DETECTOR

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

REFRIGERANT LEAK DETECTOR

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

TM-802 Formaldehyde Meter User s Manual

testo Leakage detector for refrigerants Bedienungsanleitung Instruction manual

SBS-H2 Hydrogen Gas Detector Kit

Dräger X-am 7000 Multi-Gas Detection

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Model: LD7 Dual Mode Refrigerant Gas Leak Detector. Operating Instructions

testo Leakage detector for gas Instruction manual

IMR IX176 Portable Gas Detector User Manual

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Operating Instructions. Model: LD3 Dual Mode Refrigerant Gas Leak Detector ROBINAIR.COM

Operate the Mutli-Gas Monitor PID

Model C Electronic Nose Accelerant and Gas Detector Operation and Maintenance

ESD500. ESD500 Combustible / Toxic Gas Detector

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

USER MANUAL Digital CO Monitor Model CO30

Model 850 Investigator s Aid Accelerant and Gas Detector Operation and Maintenance

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

LD900. User Manual. Refrigerant Gas Leak Detector. Detects all HFO, HFC, HCFC, and CFC Refrigerants including blends. Made in U.S.A.

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

D-TEK Select. Refrigerant Leak Detector

E1000 Portable gas detector

COMPUTHERM. CO1400 Carbon Monoxide Alarm OPERATING INSTRUCTIONS

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Sirius MultiGas Detector

4-IN-1 PIN/PAD RH MOISTURE METER

GS100M Gas Detection Controller

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

ESD3000 ESD200 Combustible / Toxic Gas Detector

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

IMR EX610. Portable Gas Detector. Operation Manual

Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120)

Model 950-ASH Arson Scanner Hydrocarbons and Accelerants Detector Operation and Maintenance

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

IRwin. Methane Leak Detector INNOVATIVE METHANE DETECTOR SYSTEM QUALITY ASSURANCE IN THE AUTOMOTIVE INDUSTRY FOR EASY SURVEY OF GAS PIPELINES

Two-Channel Gas Controller

OPERATING INSTRUCTIONS

Instruction Manual Model GX-82 Portable Three Gas Monitor

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

Instruction Manual Electronic Leak Detector. Bedienungsanleitung Elektronisches Lecksuchgerät. Mode d emploi Détecteur de fuites électronique

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

Electron Microscopy Sciences

INSTRUCTION MANUAL FOR RIKEN PORTABLE TOXIC GAS MONITOR

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

Model R9100. REED Instruments Instruction Manual. Ultrasonic Leak Detectortor

Set & $ave. Model Programmable Thermostat. installation and operation manual

Transcription:

NGD8800 USER S MANUAL COMBUSTIBLE GAS DETECTOR Please read this manual carefully and thoroughly before using this product.

CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ----------------------------------------- 2 3. SPECIFICATIONS ------------------------------- 3 4. OPERATION GUIDE --------------------------- 4 5. PARTS & CONTROLS ---------------------- 5-6 6. GETTING STARTED -------------------------- 7 6-1 Installing Batteries ------------------------- 7 6-2 Automatic Circuit/Reset Feature ------ 8 6-3 Feature Sensitivity Adjustment -------- 9 7. OPERATING PROCEDURES --------- 9-12 8. REPLACING NEW SENSOR ------------- 12 9. CLEANING --------------------------------------- 13

1. GENERAL INFORMATION 2 COMBUSTIBLE GAS DETECTOR Thank you for purchasing this Combustible Gas Detector. Read though the instruction manual before operation for correct and safe usage. Please store and retain this instruction manual for future reference. 2. FEATURES This Combustible Gas Detector is extremely useful as a general purpose tool in any environment where propane, methane, natural gas, gasoline and fuel oil is used. This unit uses a newly developed semi-conductor sensor which is extremely sensitive to variety of general use combustible gases. Microprocessor controlled with advanced digital signal processing Multi color visual display High-Low leak sensitivity selector Low battery indication Semiconductor gas sensor Detection of combustible gas Carrying case included 15.5 in. (400mm) flexible stainless probe Reference Leak source included Ambient concentration reset Application: Detect leaks in automobile exhaust and fuel system Detect leaks in liquid or gas fired heating systems Safety checks at propane filling stations Search for arson residue (detects accelerants)

Detect fuel in marine bilges Check manholes/sewers for safety Check for cracked heat exchangers Detect solvent residue 3. SPECIFICATIONS Detectable Gases: Propane, methane, natural gas, gasoline, fuel oil, CH4 (methane), H2 (hydrogen), Iso-butane, Ethanol, Ethylene, Tetrachloroethylene, Dimethyl sulfide, Toluene, Folmaldehyde, Dietyl-ether, Ethyl-acetate, Dochloromethane, NH3 (ammonia), R-22 Alarm Method: Buzzer, Tricolor LED bar Indicator Sensitivity: As low as 5ppm (methane) Power Source: 4 AA (6V DC) alkaline batteries Probe Length: 15.5 in. (400mm) Dimension / Weight: 6.8 x 2.6 x 2.2 in. (173 x 66 x 56mm) / approximately 14.1 oz. (400g) Accessories: 4 AA alkaline batteries, user s manual, leak check bottle, carry case Battery Life: Approximately 40 hours normal use Auto power OFF: 10 minutes 3

Warm-Up Time: Approximately 90 seconds Operating Temperature & Humidity: 32 to 104 F (0 to 40 C), < 80% RH Storage Temperature & Humidity: 14 to 140 F (-10 to 60 C), < 70% RH Altitude: <6500 ft. (2000m) 4. OPERATION GUIDE (1) This combustible gas detector unit is NOT designed for anti-explosive measures. Do not use this unit in an area where combustible gases can be found. (2) The following environmental conditions may cause error in the readings: Large temperature variations High wind velocity Organic solvents, adhesive vapors, fuel gas and vesicants. Try to avoid environments filled with these substances. Places filled with too much combustible gas Note: Although this unit will respond to high levels of carbon monoxide, it should NOT be used as a detector for this gas in normal room or working atmospheres. It is used to pinpoint a leak as described in the operating instruction. 4

5. PARTS & CONTROLS 5-1 Panel Description COMBUSTIBLE GAS DETECTOR 9 5

1. Sensor 2. Sensor Protector 3. LED Leak Indicators 4. Sensitivity Lo Button 5. Sensitivity Hi Button 6. Low Battery Indicator 7. Power On/Off & Reset Button 8. Battery Cover 9. Battery Cover Screw 5-2 LED Leak Indicator Definition: 6

6. GETTING STARTED 6-1 Installing Batteries Loosen the screw and remove the battery compartment door located on the bottom of the instrument as shown below (Fig.1) Install 4 AA size alkaline batteries Reinstall the battery cover by aligning it with the handle When the battery power is running low, the Red LED Low Battery indicator illuminates. The batteries should be then replaced as quickly as possible. 4 AA size alkaline batteries Fig.1 7

6-2 Automatic Ambient Reset Feature This combustible gas detector features an Automatic Ambient Reset function that sets the unit to ignore ambient concentrations of combustible gas. Automatic Ambient Setup - Upon initial power on, the unit automatically sets itself (approx. 1.5 minutes) to ignore the level of combustible gases present at the tip. Only a level, or concentration, greater than this will cause an alarm. CAUTION! This feature will cause the unit to ignore any combustible gases present at power on. In other words, with the unit OFF if you place the tip up to a known leak and switch the unit on, NO leak will be indicated! Ambient Reset Feature - Resetting the unit during operation performs a similar function; it programs the circuit to ignore the level of combustible gases present at the tip. This allows the user to 'home-in' on the source of the leak (higher concentration). Similarly, the unit can be moved to fresh air and reset for maximum sensitivity. Resetting the unit with no combustible gas present (fresh air) causes any level above zero to be detected. 8

6-3 Feature Sensitivity Adjustment The Instrument provides two levels of sensitivity. When the unit is switched on, it is set to the high sensitivity level by default. To change the sensitivity, press the key. When the key is pressed, the visual display will momentarily show the two left LED's (green) indicating Low Sensitivity level is selected. To switch back to High Sensitivity, press the key. The two right LED's (red) will light momentarily indicating high Sensitivity level is selected. 7. OPERATING PROCEDURES WARNING! 1. Do not use the instrument in an area of extremely high level of combustible gas. 2. The gas/vapor of organic solvent might interfere with the function of the unit. During detection, please eliminate the influence of the organic solvent. 3. In order to ensure correct operation and indication, the unit should be switched on and warm-up in non-contaminated atmosphere. 9

How to Find Leaks NOTE: A sudden whipping of the leak detector probe or "blowing" into the sensor tip will affect the air flow over the sensor and cause the instrument to alarm. (1) Power-Up & Reset function key: The key turns the combustible leak detector instrument ON or OFF and is also the reset function. Press it once to turn on the combustible leak detector. The display will illuminate with flash, for 1.5 minutes to heat up the sensor. Press it again to reset the ambient base concentration. Press and hold this button for 5 seconds to turn OFF the power. (2) Verify the condition of the unit and sensor: Monthly testing of unit is recommended using the included reference leak source or when even it is suspected that the reading is not correct. Set the sensitivity level to Hi. Open the leak check bottle cover and slowly move it closer to sensor. If the indication moves up to high from low then you should move the check bottle away and the LED should go off again. This shows that the unit is under working condition. If the unit does not perform as expected, bring the unit for maintenance at your local sales office. 10

(3) Enter the Measuring Mode Place the tip of the leak-detector probe as close as possible to the site of the suspected leak. Try to position the probe within 1/4 inch (6mm) of the possible leak source. Losing sensitivity gradually. Using the reference leak source to check: normally (new sensor), with the sensitivity set to high, when you move the check bottle to the sensor, the detector responds very fast (immediately detects the gas with full LED lights on and continuous beep). Older sensors: over time, sensor sensitivity drops and detection response time increases, whereby a newer sensor would activate the red LED, as opposed to an older sensor indicating a green LED. Slowly move the probe past each possible leakage point. When the instrument detects a leak source, the audible alarm will sound. Additionally, the visual indicators will light from left to right; Green LED, then Orange LED, then Red LED (highest concentration). Increasing LED levels indicate the growing proximity to the leak source. When the Instrument signals a leakage, pull the probe away from the leak for a moment, and then bring it back to pinpoint the location. If the combustible leak is large, setting the sensitivity switch to LOW will make it easier to find the exact site of the leak. 11

Return the sensitivity switch to HIGH before searching for additional leaks. When finished leak testing, turn OFF the instrument and store it in a clean place. Protect the leak detector from possible damage. 8. REPLACING NEW SENSOR The sensor has a limited operative period. Under normal operation, the sensor should be replaced once a year. Exposing the sensor to high concentration of coolant (>30000ppm) will shorten its life cycle rapidly. It is important to make sure that sensor surface is free from water droplets, vapor, oil, grease, dust and all other forms of contaminants. For proper operation, the sensors must be replaced annually or when contaminated. WARNING! When replacing sensor, the worn-out sensor may be HOT!! (1) Remove cone cap cover from the tip of the probe. (2) Pull out old sensor and insert the new sensor into the plug (see below fig.2). (3) Seal the cap cover over the plug. 12

Sensor protector Sensor Fig.2 9. CLEANING The Instrument plastic housing can be cleaned with standard household detergent or isopropyl alcohol. Care should be taken to prevent the cleaning fluid from entering the instrument. Gasoline and other solvents may damage the plastic and should be avoided. WARNING! Detergent or isopropyl alcohol may damage the sensor, please keep them away from the sensor during the cleaning process. 13

GENERAL TOOLS & INSTRUMENTS 80 White Street New York, NY 10013-3567 PHONE (212) 431-6100 FAX (212) 431-6499 TOLL FREE (800) 697-8665 e-mail: sales@generaltools.com www.generaltools.com NGD8800 User s Manual Specifications subject to change without notice 2010 GENERAL TOOLS & INSTRUMENTS Notice - we are not responsible for typographical errors. MAN#NGD8800 12/10