DUAL OPTIC. Installation manual

Similar documents
CONFIGURATION OF THE OPTICALS

INDEX. Installation recommendation

INDICE. Installation recommendation

INDEX. Installation recommendation

INDEX. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

Installation And commissioning manual. Series S Double Beam 1/16

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

English. Series. Installation and Use Manual

PARVIS Safe and tranquil thanks to Parvis

Long-Range Barrier Sensors

Perimeter protection

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Active Infrared Multi Beam Sensors

Active Infrared Multi Beam Sensors. R Series

D-Tect 2 GJD300 Quad PIR Movement Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

INFRARED MODULATED BARRIERS

BARRIERE & SENSORI BARRIERS & SENSORS

FSLIMPRO

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Twin Photobeam Detectors Manual

ITALIANO BST-100 ACTIVE INDOOR AND OUTDOOR INFRARED BARRIER WITH 2 BEAMS OF PROTECTION INSTALLATION MANUAL. Manuale istruzioni BST-100. Pag.

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Movement Detector GJD 300

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

"Pegaso" wireless alarm system

BARRIERS & SENSORS Catalogue 2017

Safety Photo Beam UL MONITORED DEVICE

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

ACTIVE INFRARED BARRIER

D-TECT Dual Tech. GJD360 Triple Technology External Detector

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Table of Contents. 1. Mounting Tips... 2

Description. Optex Incorporated

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS

Installation Instructions

WM3000 WIRELESS MODULES

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Solar Powered Wireless Photobeam Sensors

Intrusion Outdoor Protection Perimeter

Reflective Optical Beam Smoke Detector User Guide

OPTICAL TURNSTILE SYSTEM

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Instruction Manual Model A

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

English. Italiano. Português. Françias. Español

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

COMPANY PROFILE. a A SOLID REPUTATION. a DETAIL IN MANUFACTURING PROCESS. a SICURIT A TRUSTED SUPPLIER

DOLKPL1KB DOLKPS1KB DOLKSF1KB

"Pegaso" wireless alarm system D.I.Y. wireless kit

Intrusion. Outdoor protection perimeter

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

Safety Light Curtains Area Access Control

LUX Hardwired - Installation Notes

Commercial Series TriTech Motion Detector. Reference Guide

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

Pioneer-R16 Gas Monitor Operator s Manual

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

4-Row Active Infrared Presence Detector for Automatic Door Control. Cover

HX-80NRAM. High Mount Outdoor Detector

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

1 Safety instructions. 2 Device components. Presence detector. Operating instructions

DOLKPS1KB Programming & Installation Manual

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

Beacon 410A Gas Monitor Operator s Manual

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Topscan G3 Presence detector for automatic doors

RMS/RPX Reader. User Manual

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

THE BEST SOLUTIONS FOR OUTDOOR PERIMETER PROTECTIONS

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Infrared Single Light Barrier. Mounting Instructions DO560

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

Transcription:

DUAL OPTIC Installation manual

INDEX 1 COMPONENTS Pag. 3 2 MOUNTING EXAMPLES Pag. 4 MOUNTING WITH BRACKETS Pag. 5 3 INSTALLATION EXAMPLES Pag. 6 4 CABLES AND CABLING Pag. 7 CONNECTION AND HEATING SETTING Pag. 8 5 OPTICAL CONFIGURATION Pag. 9 TX OPTICAL Pag. 9 RX OPTICAL Pag. 10 3 RX/TX SETTINGS Pag. 11 2 RX/TX SETTINGS Pag. 11 6 COLUMN ALIGNEMENT Pag. 12 7 CALIBRATION THROUGH SMA SYSTEM Pag. 13 8 CALIBRATION WITH PARALLEL BEAMS Pag. 17 9 CALIBRATION WITH CROSSING BEAMS Pag. 18 10 SETTINGS AND PROGRAMMING SCHEDA QUAD TX Pag. 19 DIP SWITCHES DESCRIPTION Pag. 20 LED DESCRIPTION Pag. 20 CONNECTOR DESCRIPTION & FUNCTIONALITY Pag. 20 11 SETTINGS AND PROGRAMMING QUAD RX Pag. 21 DESCRIPTION DIP SWITCHES Pag. 22 DIP SW 1 Pag. 22 DIP SW 2 Pag. 22 LED DESCRIPTION Pag. 23 CONNECTOR DESCRIPTION & FUNCTIONALITY Pag. 23 12 RESPONSE TIME SETTINGS Pag. 23 13 TECHNICAL CHARATTERISTICS Pag. 24 Installation recommendation Verify that the beam tower is fully watertight once the cover and end caps have been correctly filled at the end of the installation. Use the cable glands supplied on the tower for all cabling must pass through the lower end cap using the cable glands supplied. The missed used of proper accessories decrease the IP grade protection of the tower. Avoid any type of obstruction between the transmitter and receiver. Avoid installing the receivers beams in a position where direct sunlight, at the same angle as the receivers beams, can enter directly into optics especially at sunset and sunrise Do not install multiple beams where the transmitter beam can interfere with other receiver beams. It is always better place either transmitter or receivers back to back. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 2

1 MAIN COMPONENTS LIST 3 4 2 N Descrizione Parte 1 Aluminium profile 2 IR cover 3 Caps 4 Opticals RX/TX 5 Terminals board 6 Mother board 1 6 5 POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 3

2 MOUNTING SAMPLES Pole mounting with SAN/PL Wall mounting with SAN/SD Wall mounting with SAN/PL POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 4

MOUNTING WITH BRACKETS Insert the bracket on the back Pole mounting with SAN/PL Diameter pole max 48 mm Wall mounting with SAN/PL Wall mounting with SAN/SD N.B.: we recommend the use of the brackets SAN / PL on the wall when you place the protection of gates (windows, doors,...) along the wall to avoid small obstacles (hinges, edges of window sills,...) that could create signal attenuation. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 5

3 INSTALLATION EXAMPLES For an installation to control the perimeter install the barriers as shown: For an installation of barriers overlapped position the barriers as well as in the figure: TX RX RX TX POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 6

4 CABLES AND CABLING The wiring requires to SEPARATE the power cable 12Vdc (ex. 2x0.5 + Nx0.22),to the power cable for heaters 24Vac (ex. 2x0.75) to prevent input of disorders of the AC voltage on the barrier. N.B. is absolutely necessary to shield the cable that provides 12 Vdc power supply and put the metal braid to ground. The cable size depends on the consumption of the columns and the resistance of the cable to the distances involved. The table shows the cable sections and the relative distances to which they provide optimum performance using the supplier LAR22 (12Vdc - 2,5A / 24V AC-300W) and a barrier SANDOR QUAD / ESA SMA. Cable section 12Vdc 24Vac 0,5 mm² 165 m 35 m 0,75 mm² 245 m 50 m 1,5 mm² 490 m 100 m 2,5 mm² 820 m 165 m 4 mm² 1310 m 265 m 6 mm² 1975 m 400 m N.B. THE LAR22 IS NOT WATERPROOF, MUST BE PLACED INSIDE A LOCAL OR PLACED IN A SEALED CONTAINER FOR USE OUTSIDE. Is possible use the power supplier LAR18 (12Vdc 0,9A / 24VAC-60W) to supply a single column. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 7

CONNECTION AND HEATING SETTING The power of the heaters is by default set to 24 Vac, but you can set it to 12 Vdc repositioning the jumper on both RX and TX mother boards and on each optical as shown. OPTICAL 12Vdc 24Vac MOTHER BOARD 12Vdc 24Vac POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 8

5 OPTICAL CONFIGURATION TX OPTICAL TAMPER SUPPLY LED HEATERS SUPPLY 12Vdc 24Va ESA MODEL TX1 TX2 TX3 TX4 TX5 TX6 1 2 3 4 5 6 7 1 2 3 4 5 6 To test the functionality of optics TX put ON the DIP 7 and see the activation of the power LED. Set SW4 to supply of the heaters. 24V (standard) or 12V. The voltage can be AC or DC. NB: The settings relating to addresses are already set to Default. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 9

RX OPTICAL TEST SIGNAL TAMPER LOW SIGNAL LED HEATER SUPPLY 12Vdc 24Vac ESA TX1 TX2 TX3 TX4 TX5 TX6 1 2 3 4 5 6 7 1 2 3 4 5 6 To test the functionality of optics TX put ON the DIP 7 and see the activation of the power LED. Set SW4 to supply of the heaters. 24V (standard) or 12V. The voltage can be AC or DC. In the J4 jumper reads the value of the signal in volts. NB: The settings relating to addresses are already set to Default. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 10

3 RX / TX SETTING The setting of the DIP SWITCH on optical is amended as follows: 1 2 3 4 5 6 7 1 2 3 4 5 6 1 2 3 4 5 6 7 1 2 3 4 5 6 RX1 TX1 RX2 RX3 TX2 TX3 It should be set to ON the DIP on the motherboard RX exclusion 4 2 RX / TX SETTING The setting of the DIP SWITCH on optical is amended as follows: RX1 RX2 1 2 3 4 5 6 7 1 2 3 4 5 6 1 2 3 4 5 6 7 1 2 3 4 5 6 TX1 TX2 It should be set to ON the DIP on the motherboard RX exclusion 3 + 4 POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 11

6 COLUMN ALIGNEMENT For proper alignment, once the barriers are installed, orient the optical of transmitters and receivers in the direction of each other by adjusting the lens holder horizontally through the manual movement after loosening the locking screw on the joint, and vertically through the front screw on the left side of the lens. Vertical adjustment Horizontal adjustment SCREW N.B.: FASTEN THE UNLOCKING SCREW AFTER THE ADJUSTMENT POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 12

7 CALIBRATION THROUGH SMA SYSTEM You can improve the calibration through the use of the supplied filter 1) Fold the device according to the preset creases 2) Place the filter in front of the optics TX placing the two hooks on the pins of the fork optics to refine the search for the signal alignment with critical conditions. You simply apply the filter only on the TX, it is not necessary to repeat the operation on the RX also. 3) Start the alignment of the transmitter is on the barrier by checking the position of the DIP switch 7 to ON and activating the TEST optics TX (1 or 2 or 3 or 4), by pressing the dedicated button for about 3 seconds until the orange LED TEST will lit up. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 13

DIP 7 ON TO ACTIVATE THE LED DIP 7 ON ORANGE LED TEST BUTTON 4) Place in the corresponding optical TEST (1 or 2 or 3 or 4) on coral receiver, checking the position of the DIP switch 7 to ON and pressing the dedicated button for 3 seconds until the the BUZZER and the LED TEST turns ON, (with high brightness) DIP 7 ON TO ACTIVATE THE LED DIP 7 ON ORANGE LED TEST BUTTON POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 14

5) Through the TRANSMITTER lens shifts, find the maximum optical alignment based on the Buzzer and LEDs (with high brightness), the increase in the frequency of flashing (until the LEDs is fix on and the whistle of the corresponding BUZZER) indicate a better ALIGNMENT. 6) With a FULL rotation on the horizontal RX lens, is carried out the SCANNING of the optical signal. 7) Rotating the lens RX find the maximum value of ALIGNMENT corresponding to the LEDs (with high brightness) FIXED and the whistle of the BUZZER CONTINUOUS. 8) Exit the function of by repressing the ALIGNMENT TEST button for about 3 seconds on both optics (TX-RX) making sure that the orange LED TEST is shown in original condition. 9) When finished, remove the shade that acts as a dampener, having the certainty of having found the optimum value. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 15

10) Set the DIP switch 7 to OFF to ALL OPTICAL if you want to turn off the LEDs. DIP 7 OFF TO SWITCH OFF THE LED DIP 7 OFF NB: you can SEE the calibration value through the multimeter on each optical receiver. For this procedure, you must have the pair of lenses (TX-RX) in TEST. J4 POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 16

8 PARALLEL BEAM CALIBRATION Put in TEST the optical TX1 and RX1 if present (see p.10-11), and proceed with the calibration as explained above. Put in TEST the optical TX2 and RX2 if present (see p.10-11), and proceed with the calibration as explained above. Put in TEST the optical TX3 and RX3 if present (see p.10-11), and proceed with the calibration as explained above. Put in TEST the optical TX1 and RX1 if present (see p.10-11), and proceed with the calibration as explained above. N.B.: during the testing phase of an optical transmitter the other TX not in test are switched off automatically. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 17

9 CALIBRATION WITH CROSSED BEAMS To activate move the DIP. 4 ON of the board QUAD RX (Chapter 10). 1 2 3 4 Perform the alignement putting on test one optical per time ON Activate the TEST for TX1 and check for proper alignment of optics at a time using the TEST on RX1 and AFTER RX2, RX3, RX4 making sure that TX1 still aligned with RX1. In the same way TEST the TX2, TX3, TX4, NB: It 'requires a minimum distance of at least 8 meters so that the first optical receiver see the last transmitter and vice versa. Especially if you use the ESA configuration with 6 optical receivers, and 6 optical transmitters. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 18

10 SETTING AND PROGRAMMING QUAD TX TAMPER HEATERS SUPPLY ADJUSTMENT 12 V 12 V 24 V 24 V LED SUPPLY LED HEATERS DIP SWITCHES HEATER SUPPLY 12-24 Vdc SUPPLY 12-30 Vdc TAMPER POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 19

DIP SWITCHES DESCRIPTION The board has a single serie of dip switches for the configuration of the transmitter 1 Tx channel 1 2 Tx channel 2 3 Tx channel 3 4 Tx channel 4 5 BEAM 3: 3 TX active 6 BEAM 4: 4 TX active 7 BEAM 5: 5 TX active (ESA) 8 BEAM 6: 6 TX active (ESA) 9 TX OFF: all TX OFF 10 LED: All led active 1 2 3 4 5 6 7 8 9 10 LED DESCRIPTION I led saranno accesi solo se il dip switch 10 è impostato su ON. ON LED POWER LED RISCALDATORI Indicates the mother board ON Indicates the status of heaters. It will be activated if the temperature inside the barrier become below 18 C CONNECTORS DESCRIPTION AND FUNCTIONALITY The connector has: Supply 10-30Vdc Tamper output Supply 12-24Vac-dc for heaters on board QUAD-ESA and on the optical. On the card is provided an input for the tamper. In case of absence of that close the input with a jumper POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 20

11 SETTING AND PROGRAMMING QUAD RX TAMPER HEATERS SUPPLY RESPONSE TIME 12 V 12 V 24 V 24 V SUPPLY LED ALARM LED DISQUALIFICATION LED HEATERS LED DIP SWITCHES 1 DIP SWITCHES 2 AND DISQUALIFICATION HEATERS SUPPLY 12-24 Vdc ALARM SUPPLY 12-30 Vdc TAMPER POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 21

DIP SWITCHES DESCRIPTION The card has two series of dip switches where you can set different configurations: DIP SW1 1 2 3 4 5 6 7 8 9 10 1 Tx channel 1 2 Tx channel 2 3 Tx channel 3 4 Tx channel 4 5 BEAM 3: 3 TX active 6 BEAM 4: 4 TX active 7 BEAM 5: 5 TX active (ESA) 8 BEAM 6: 6 TX active (ESA) 9 Relay N.O.: if ON, the alarm relay will be N.O. otherwise it will be N.C 10 All led active DIP SW2 1 2 3 4 1 AND The Barrier goes in alarm only if at least 2 beam are interrupted 2 AND 1-2 The AND condition is only for the beams 1 & 2 3 DISQ Disqualification activated 4 CRO If ON the system will operate with crossed beams ON ON POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 22

The led are active ONLY if the dip 10 is ON LED DESCRIPTION LED POWER LED ALARM LED DISQUALIFICA LED RISCALDATORI Indicates the mother board in ON Goes ON in Alarm Indicates the disqualification active. The alarm relay is inibhited also if the alarm led is ON Indicates the status of heaters. It will be activated if the temperature inside the barrier become below 18 C CONNECTORS DESCRIPTION AND FUNCTIONALITY The connector has: Supply 10-30Vdc Tamper output Supply 12-24Vac-dc for heaters on board QUAD-ESA and on the optical Aarm relay that can be N.O. or N.C. as set before. AND remoted remoto: giving a negative input the system works in AND. DISQUALIFICA: NEGATIVE OPEN COLLECTOR in case of fog On the card is provided an input for the tamper. In case of absence of that close the input with a jumper 12 RESPONSE TIME ADJUSTMENT There is a potentiometer to adjust the TIME OF INTERVENTION. In particular, you can set the barrier for the rapid alert system (cross running) or slow (cross by walk). By adjusting the potentiometer counterclockwise to increase the trip time up to 500ms. In this condition ensures that the alarm of a person walking through the barrier, with the advantage of excluding the possibility of any false alarms (ex. animals). Adjusting the potentiometer clockwise decreases the trip time until 50ms. In this condition ensures the alarm of a person crossing the barrier running at maximum speed. POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 23

13 TECHNICAL CHARACTERISTICS MODELS DUAL SMA QUAD SMA ESA SMA Max range indoor 450 m Max range outdoor 100 m Min distance 4 m 8 m Min Heigh of column 35 cm 1 m 1,5 m 2,0 m Synchronism Optic Beams total 4 (crossed) 16(crossed) 36 (crossed) Alimentazione 12Vdc Power consumption Tx 30 ma+rx 60 ma Tx 30 ma+rx 50 ma Tx 80 ma+rx 80 ma Heaters 10W + 10W 24Vac 20W +20W 24Vca Thermostated 30W+30W 24Vca Thermostated OPERATING TEMPERATURE 25 / +65. Available Kit heaters for temperatures up to -50 C. VERTICAL ADJUSTMENT 20 HORIZONTAL ADJUSTMENT 180 DETECTION FUNCTION AND/OR Tx E Rx ALSO FROM REMOTE ALARM RELAY NC/NO TAMPER NC DISQUALIFICATION OPEN COLLECTOR LED EXCLUDIBLE INFRARED Impulsive double lenses 950 nm PROTECTION DEGREE IP 65 ACCESSORIES FOR WALL MOUNTING ACCESSORIES FOR POLE MOUNTING POLITEC s.r.l. Sandor QUAD-ESA SMA Manual Ver. 2.5 24