TECHNICAL MANUAL. INVERTER MULTI-SPLIT SYSTEM RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type)

Similar documents
FDU71KXE6 FDU90KXE6 FDU112KXE6 FDU140KXE6 FDU224KXE6 FDU280KXE6

6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)

TECHNICAL MANUAL. INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type)

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

SRK20ZFX-S, 25ZFX-S, 35ZFX-S, 50ZFX-S

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

TECHNICAL MANUAL INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS

Кондиционеры Mitsubishi Heavy

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

4. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air to air heat pump type)

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

1. WALL MOUNTED TYPE ROOM AIR-CONDITIONER Split system, Air to air heat pump type

TECHNICAL MANUAL. INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type) SRK25ZJP-S SRK35ZJP-S SRK50ZJP-S

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

TECHNICAL MANUAL. INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS (Split system, air to air heat pump type) SRK25ZMP-S SRK35ZMP-S SRK45ZMP-S

TECHNICAL MANUAL INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONERS

PRODUCT INFORMATION (*) Y cooling Y Warmer (if designated) N heating Y Colder (if designated)

SG79V571H02_print outline.pdf 2012/10/23 17:32:06 CMY

PRODUCT INFORMATION (*) Y cooling Y Warmer (if designated) N heating Y Colder (if designated)

BH79B928H01_print_outline.pdf 2013/09/30 14:10:38 CMY

INVERTER WALL MOUNTED TYPE RESIDENTIAL AIR-CONDITIONER ( Split system, air to air heat pump type )

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

DESIGN & TECHNICAL MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Air Conditioning Technical Data AZAS-MY1

Digital Inverter 4 series 8 & 10HP

WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

WALL MOUNTED TYPE ROOM AIR-CONDITIONER

AIR-CONDITIONER SERVICE MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Installer manual AMS 10

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

WPL 17 IKCS classic 55 C 35 C A ++ A ++ A ++ A + A B C D E F G kw kw. 50 db. 44 db

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

WPL 23 E 55 C 35 C A ++ A + A B C D E F G A + A kw kw. 58 db. 65 db

TABLE OF CONTENTS ERSQ-AAY1

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL

WPL C 35 C A ++ A + A B C D E F G A + A kw kw. 69 db

DESIGN & TECHNICAL MANUAL

Air Conditioner SVC MANUAL(Exploded View)

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SUBMITTAL DATA: PVA-A36AA7 & PUZ-HA36NHA5 36,000 BTU/H AIR HANDLER HEAT PUMP SYSTEM. Job Name: System Reference:

Part 3 Troubleshooting

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

TECHNICAL DATA & SERVICE MANUAL

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

(Split system, air to air heat pump type)

TABLE OF CONTENTS RMXS-E8V1B

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

Air Conditioners. Technical Data RZQG-L

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Wireless type Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Advance Split

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

R4H4. Product Specifications

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Installer manual NIBE F , 12, 16 kw UK 1x230V Air/water heat pump IHB GB LEK LEK LEK

FLOOR CONSOLE / UNDER CEILING DUAL type (60Hz)

CASSETTE type INVERTER MULTI AIR CONDITIONER

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL & SERVICE MANUAL

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

FLOOR CONSOLE / UNDER CEILING DUAL type

Single Zone Air Conditioner SVC MANUAL (Exploded View)

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Engineering Data Manual

R4H4. Product Specifications

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

Air Conditioner CONTENTS

Transcription:

Manual No.'14 SCM-T-167 updated November 27, 2014 TECHNICL MNUL INVERTER MULTI-SPLIT SYSTEM RESIDENTIL IR-CONDITIONERS (Split system, air to air heat pump type) (OUTDOOR UNIT) SCM40ZM-S 45ZM-S 50ZM-S 60ZM-S (INDOOR UNIT) Wall mounted type SRK20ZMX-S 25ZMX-S 35ZMX-S 50ZMX-S 60ZMX-S SRK20ZM-S 25ZM-S 35ZM-S 50ZM-S SRK71ZM-S SCM71ZM-S 80ZM-S 100ZM-S 125ZM-S Floor standing type SRF25ZMX-S 35ZMX-S 50ZMX-S 4way ceiling cassette type FDTC25VF 35VF 50VF 60VF Ceiling concealed type SRR25ZJ-S 35ZJ-S 50ZJ-S 60ZJ-S1 Ceiling suspended type FDEN50VF Duct connected Low/Middle static pressure type FDUM50VF

CONTENTS 1. SPECIFICTIONS... 2 2. EXTERIOR DIMENSIONS... 10 3. ELECTRICL WIRINGS... 15 4. TECHNICL INFORMTION... 20 (1) Model SCM40ZM-S... 20 (2) Model SCM45ZM-S... 22 (3) Model SCM50ZM-S... 24 (4) Model SCM60ZM-S... 28 (5) Model SCM71ZM-S... 32 (6) Model SCM80ZM-S... 38 (7) Model SCM100ZM-S... 44 This technical manual describes matters related to the outdoor s. For any others and those related to the indoor s, refer to the Technical Manual 14 SCM-T-150. For applicable models, refer to the following comparison table. Table of outdoor models Outdoor SCM40ZM-S SCM45ZM-S SCM50ZM-S SCM60ZM-S SCM71ZM-S SCM80ZM-S SCM100ZM-S SCM125ZM-S Regarding the outdoor SCM40ZJ-S SCM45ZJ-S SCM50ZJ-S1 SCM60ZJ-S1 SCM71ZJ-S1 SCM80ZJ-S1 SCM100ZJ-S1 SCM125ZJ-S1 - -

1. SPECIFICTIONS Item Model SCM40ZM-S capacity (1) W 4000 (1800 (Min.) 5900 (Max.)) Heating capacity (1) W 4500 (1400 (Min.) 6900 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 0.84 (0.49 1.90) kw consumption Heating 0.90 (0.47 2.30) Running 3.9 / 3.7 / 3.5 (220 / 230 / 240 V) current Heating 4.1 / 4.0 / 3.8 (220 / 230 / 240 V) Inrush current 4.1 / 4.0 / 3.8 (220 / 230 / 240 V) Operation Max current (5) 14 data (1) 4.76 COP Heating 5.00 Sound level db () 47 Noise Power level db 60 level Sound level db () 48 Heating Power level db 62 Exterior dimensions (Height x Width x Depth) mm 640 x 850 x 290 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 47 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5113MDE2 (Twin rotary type) x 1 Motor (Starting method) kw 1.4 (Line starting) Refrigerant oil 0.45 (DIMOND FREEZE M68) Refrigerant (4) kg R410 2 (Pre-Charged up to the piping length of 30m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 34 ir flow 40.0 m 3 /min Heating 40.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") 2 Gas line: φ9.52 (3/8") 2 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 30 Vertical height difference between m Max. 15 (Outdoor is higher) outdoor and indoor Max. 15 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 25 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Installation sheet, Elbow, Grommet SRK20,25,35ZMX()-S SRK20,25,35ZM()-S Indoor to be combined SRF25,35ZMX()-S SRR25,35ZJ-S FDTC25,35VF Number of connectable indoor s 2 Total of indoor s kw Max. 6 Note (1) The data are measured at the following conditions. The pipe length for one indoor is 7.5m. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB Standards 27 C 19 C 35 C 24 C Heating 20 C 7 C 6 C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220/230/240V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 30m connecting piping. (Purging is not required even for the short piping.) (5) Current value at maximum number of indoor s connected. dapted to RoHS directive - -

Item Model SCM45ZM-S capacity (1) W 4500 (1800 (Min.) 6400 (Max.)) Heating capacity (1) W 5600 (1400 (Min.) 7400 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 1.04 (0.49 2.14) kw consumption Heating 1.20 (0.47 2.57) Running 4.8 / 4.6 / 4.4 (220 / 230 / 240 V) current Heating 5.5 / 5.3 / 5.1 (220 / 230 / 240 V) Inrush current 5.5 / 5.3 / 5.1 (220 / 230 / 240 V) Operation Max current (5) 14 data (1) 4.33 COP Heating 4.67 Sound level db () 47 Noise Power level db 60 level Sound level db () 49 Heating Power level db 62 Exterior dimensions (Height x Width x Depth) mm 640 x 850 x 290 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 47 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5113MDE2 (Twin rotary type) x 1 Motor (Starting method) kw 1.4 (Line starting) Refrigerant oil 0.45 (DIMOND FREEZE M68) Refrigerant (4) kg R410 2 (Pre-Charged up to the piping length of 30m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 34 ir flow 40.0 m 3 /min Heating 40.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") 2 Gas line: φ9.52 (3/8") 2 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 30 Vertical height difference between m Max. 15 (Outdoor is higher) outdoor and indoor Max. 15 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 25 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Installation sheet, Elbow, Grommet SRK20,25,35ZMX()-S SRK20,25,35ZM()-S Indoor to be combined SRF25,35ZMX()-S SRR25,35ZJ-S FDTC25,35VF Number of connectable indoor s 2 Total of indoor s kw Max. 7 Note (1) The data are measured at the following conditions. The pipe length for one indoor is 7.5m. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB Standards 27 C 19 C 35 C 24 C Heating 20 C 7 C 6 C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220/230/240V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 30m connecting piping. (Purging is not required even for the short piping.) (5) Current value at maximum number of indoor s connected. dapted to RoHS directive - -

Item Model SCM50ZM-S capacity (1) W 5000 (1800 (Min.) 7100 (Max.)) Heating capacity (1) W 6000 (1400 (Min.) 7500 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 1.08 (0.50 2.15) kw consumption Heating 1.31 (0.48 2.58) Running 5.0 / 4.7 / 4.5 (220 / 230 / 240 V) current Heating 6.0 / 5.8 / 5.5 (220 / 230 / 240 V) Inrush current 6.0 / 5.8 / 5.5 (220 / 230 / 240 V) Operation Max current (5) 15 data (1) 4.63 COP Heating 4.58 Sound level db () 49 Noise Power level db 62 level Sound level db () 52 Heating Power level db 65 Exterior dimensions (Height x Width x Depth) mm 640 x 850 x 290 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 48 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5113MDE2 (Twin rotary type) x 1 Motor (Starting method) kw 1.4 (Line starting) Refrigerant oil 0.45 (DIMOND FREEZE M68) Refrigerant (4) kg R410 2.5 (Pre-Charged up to the piping length of 40m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 34 ir flow 41.0 m 3 /min Heating 41.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data dapted to RoHS directive Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") 3 Gas line: φ9.52 (3/8") 3 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 40 Vertical height difference between m Max. 15 (Outdoor is higher) outdoor and indoor Max. 15 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 25 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Union : (φ9.52 扌 φ12.7 ) 1, Installation sheet, Elbow, Grommet SRK20,25,35,50ZMX()-S SRK20,25,35,50ZM()-S Indoor to be combined SRF25,35,50ZMX()-S SRR25,35,50ZJ-S FDTC25,35,50VF FDEN50VF,FDUM50VF Number of connectable indoor s Min. 2 Max. 3 Total of indoor s kw Max. 8.5 Note (1) The data are measured at the following conditions. The pipe length for one indoor is 7.5m. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB Standards 27 C 19 C 35 C 24 C Heating 20 C 7 C 6 C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220/230/240V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 40m connecting piping. (Purging is not required even for the short piping.) (5) Current value at maximum number of indoor s connected. - -

Item Model SCM60ZM-S capacity (1) W 6000 (1800 (Min.) 7500 (Max.)) Heating capacity (1) W 6800 (1500 (Min.) 7800 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 1.43 (0.50 2.39) kw consumption Heating 1.51 (0.60 3.00) Running 6.8 / 6.5 / 6.2 (220 / 230 / 240 V) current Heating 7.1 / 6.8 / 6.6 (220 / 230 / 240 V) Inrush current 7.1 / 6.8 / 6.6 (220 / 230 / 240 V) Operation Max current (5) 17 data (1) 4.2 COP Heating 4.5 Sound level db() 50 Noise Power level db 63 level Sound level db() 52 Heating Power level db 65 Exterior dimensions (Height x Width x Depth) mm 640 x 850 x 290 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 49 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5118MDE2 (Twin rotary type) x 1 Motor (Starting method) kw 1.4 (Line starting) Refrigerant oil 0.675 (DIMOND FREEZE M68) Refrigerant (4) kg R410 2.5 (Pre-Charged up to the piping length of 40m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 34 ir flow 42.0 m 3 /min Heating 42.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line:φ6.35 (1/4") 3 Gas line:φ9.52 (3/8") 3 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 40 Vertical height difference between m Max. 15 (Outdoor is higher) outdoor and indoor Max. 15 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 25 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Union : (φ9.52 扌 φ12.7) 2, Installation sheet, Elbow, Grommet SRK20,25,35,50,60ZMX()-S SRK20,25,35,50ZM()-S Indoor to be combined SRF25,35,50ZMX()-S SRR25,35,50ZJ-S,60ZJ-S1 FDTC25,35,50,60VF FDEN50VF,FDUM50VF Number of connectable indoor s Min. 2 Max. 3 Total of indoor s kw Max. 11 Note (1) The data are measured at the following conditions. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB 27 C 19 C 35 C 24 C Heating 20 C 7 C 6 C The pipe length for one indoor is 7.5m. (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220/230/240V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 40m connecting piping. (Purging is not required even for the short piping.) (5) Current value at maximum number of indoor s connected. Standards ISO-T1, JIS C 9612 dapted to RoHS directive - -

Item Model SCM71ZM-S capacity (1) W 7100 (1800 (Min.) 8800 (Max.)) Heating capacity (1) W 8600 (1500 (Min.) 9400 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 1.74 (0.48 2.75) kw consumption Heating 2.00 (0.60 3.35) Running 8.0 / 7.6 / 7.3 (220 / 230 / 240 V) current Heating 9.2 / 8.8 / 8.4 (220 / 230 / 240 V) Inrush current 9.2 / 8.8 / 8.4 (220 / 230 / 240 V) Operation Max current (5) 20 data (1) 4.08 COP Heating 4.30 Sound level db () 52 Noise Power level db 65 level Sound level db () 54 Heating Power level db 66 Exterior dimensions (Height x Width x Depth) mm 750 x 880 x 340 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 62 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5118MDE2 (Twin rotary type) x 1 Motor (Starting method) kw 1.4 (Line starting) Refrigerant oil 0.675 (DIMOND FREEZE M68) Refrigerant (4) kg R410 3.15 (Pre-Charged up to the piping length of 40m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 86 ir flow 56.0 m 3 /min Heating 56.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data dapted to RoHS directive Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") 4 Gas line: φ9.52 (3/8") 4 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 70 Vertical height difference between m Max. 20 (Outdoor is higher) outdoor and indoor Max. 20 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 25 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Union : (φ9.52 扌 φ12.7) 2, Installation sheet, Elbow, Grommet 2 SRK20,25,35,50,60ZMX()-S SRK20,25,35,50ZM()-S Indoor to be combined SRF25,35,50ZMX()-S SRR25,35,50ZJ-S,60ZJ-S1 FDTC25,35,50,60VF FDEN50VF,FDUM50VF Number of connectable indoor s Min. 2 Max. 4 Total of indoor s kw Max. 12.5 Note (1) The data are measured at the following conditions. The pipe length for one indoor is 7.5m. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB Standards 27 C 19 C 35 C 24 C Heating 20 C 7 C 6 C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220/230/240V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 40m connecting piping. (Purging is not required even for the short piping.) (5) Current value at maximum number of indoor s connected. - -

Item Model SCM80ZM-S capacity (1) W 8000 (1800 (Min.) 9200 (Max.)) Heating capacity (1) W 9300 (1500 (Min.) 9800 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 2.16 (0.48 2.83) kw consumption Heating 2.26 (0.60 3.43) Running 9.9 / 9.4 / 9.0 (220 / 230 / 240 V) current Heating 10.4 / 10.0 / 9.5 (220 / 230 / 240 V) Inrush current 10.4 / 10.0 / 9.5 (220 / 230 / 240 V) Operation Max current (5) 20 data (1) 3.70 COP Heating 4.12 Sound level db() 54 Noise Power level db 66 level Sound level db() 54 Heating Power level db 66 Exterior dimensions (Height x Width x Depth) mm 750 x 880 x 340 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 62 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5118MDE2 (Twin rotary type) x 1 Motor (Starting method) kw 1.4 (Line starting) Refrigerant oil 0.675 (DIMOND FREEZE M68) Refrigerant (4) kg R410 3.15 (Pre-Charged up to the piping length of 40m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 86 ir flow 56.0 m 3 /min Heating 56.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data dapted to RoHS directive Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line:φ6.35 (1/4") 4 Gas line:φ9.52 ( 3/8") 4 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 70 Vertical height difference between m Max. 20 (Outdoor is higher) outdoor and indoor Max. 20 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 25 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Union : (φ9.52 扌 φ12.7) 2, Installation sheet, Elbow, Grommet 2 SRK20,25,35,50,60ZMX()-S SRK20,25,35,50ZM()-S Indoor to be combined SRF25,35,50ZMX()-S SRR25,35,50ZJ-S,60ZJ-S1 FDTC25,35,50,60VF FDEN50VF,FDUM50VF Number of connectable indoor s Min. 2 Max. 4 Total of indoor s kw Max. 13.5 Note (1) The data are measured at the following conditions. The pipe length for one indoor is 7.5m. Item Indoor air temperature Outdoor air temperature Operation DB WB DB WB Standards 27 C 19 C 35 C 24 C Heating 20 C 7 C 6 C ISO-T1, JIS C 9612 (2) This air-conditioner is manufactured and tested in conformity with the ISO. (3) The operation data are applied to the 220/230/240V districts respectively. (4) The refrigerant quantity to be charged includes the refrigerant in 40m connecting piping. (Purging is not required even for the short piping.) (5) Current value at maximum number of indoor s connected. - -

Item Model SCM100ZM-S capacity (1) W 10000 (1800 (Min.) 12000 (Max.)) Heating capacity (1) W 12000 (1500 (Min.) 13500 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 2.86 (0.65 4.03) kw consumption Heating 2.93 (0.70 3.40) Running 13.0 / 12.4 / 11.9 (220 / 230 / 240 V) current Heating 13.3 / 12.8 / 12.2 (220 / 230 / 240 V) Inrush current 13.3 / 12.8 / 12.2 (220 / 230 / 240 V) Operation Max current (6) 28 data (1) 3.50 COP Heating 4.10 Sound level db () 56 Noise Power level db 68 level Sound level db () 59 Heating Power level db 71 Exterior dimensions (Height x Width x Depth) mm 945 x 970 x 370 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 92 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5126MDE21 (Twin rotary type) x 1 Motor (Starting method) kw 4.0 (Line starting) Refrigerant oil 1.0 (DIMOND FREEZE M68) Refrigerant (4) kg R410 6.00 (Pre-Charged up to the piping length of 50m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 86 ir flow 75.0 m 3 /min Heating 75.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") 5 Gas line: φ9.52 (3/8") 5 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 90 Vertical height difference between m Max. 20 (Outdoor is higher) outdoor and indoor Max. 20 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 30 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Union, Installation sheet, Elbow, Grommet 2 SRK20,25,35,50,60ZMX()-S,SRK20,25,35,50,71ZM()-S SRF25,35,50ZMX()-S Indoor to be combined SRR25,35,50ZJ-S,60ZJ-S1 FDTC25,35,50,60VF FDEN50VF,FDUM50VF Number of connectable indoor s Min. 2 Max. 5 (5) Total of indoor s kw Max. 16.0 Note (1) The data are measured at the following conditions. - - #

Item Model SCM125ZM-S capacity (1) W 12500 (1800 (Min.) 14000 (Max.)) Heating capacity (1) W 13500 (1500 (Min.) 14000 (Max.)) Power source 1 Phase, 220 240 V, 50Hz Power 3.90 (0.65 4.80) kw consumption Heating 3.25 (0.70 3.42) Running 17.7 / 17.0 / 16.3 (220 / 230 / 240 V) current Heating 14.8 / 14.1 / 13.6 (220 / 230 / 240 V) Inrush current 17.7 / 17.0 / 16.3 (220 / 230 / 240 V) Operation Max current (6) 29 data (1) 3.21 COP Heating 4.15 Sound level db () 57 Noise Power level db 69 level Sound level db () 60 Heating Power level db 72 Exterior dimensions (Height x Width x Depth) mm 945 x 970 x 370 Exterior appearance (Munsell color) Stucco white (4.2Y 7.5/1.1) near equivalent Net weight kg 92 Refrigerant equipment ir handling equipment Compressor type & Q'ty RM-T5126MDE21 (Twin rotary type) x 1 Motor (Starting method) kw 4.0 (Line starting) Refrigerant oil 1.0 (DIMOND FREEZE M68) Refrigerant (4) kg R410 6.00 (Pre-Charged up to the piping length of 50m) Heat exchanger M fins & inner grooved tubing Refrigerant control Capillary tubes + Electronic expansion valve Device control Microcomputer control Fan type & Q'ty Propeller fan x 1 Motor W 86 ir flow 75.0 m 3 /min Heating 82.0 Cushion rubber (for compressor) Shock & vibration absorber Electric heater Crank case heater (220V 20W) Safety devices Installation data Compressor overheat protection, Overcurrent protection, Frost protection, Serial signal error protection, Outdoor fan motor error protection, Heating & overload protection Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") 6 Gas line: φ9.52 (3/8") 6 Connecting method Flare connecting Insulation for piping Necessary (Both sides), independent Length for one indoor Max. 25 Total length for all rooms Max. 90 Vertical height difference between m Max. 20 (Outdoor is higher) outdoor and indoor Max. 20 (Outdoor is lower) Height difference of the indoor s Max. 25 Recommended breaker size 30 Connection wiring Size x Core number 1.5mm2 x 4 cores (Including earth cable) Connecting method Terminal block (Screw fixing type) IP number IPX4 ccessories (included) Union, Installation sheet, Elbow, Grommet 2 SRK20,25,35,50,60ZMX()-S,SRK20,25,35,50,71ZM()-S SRF25,35,50ZMX()-S Indoor to be combined SRR25,35,50ZJ-S,60ZJ-S1 FDTC25,35,50,60VF FDEN50VF,FDUM50VF Number of connectable indoor s Min. 2 Max. 6 (5) Total of indoor s kw Max. 19.5 Note (1) The data are measured at the following conditions. - - #

- 10-290 Symbol Content Service valve connection(gas side) φ9.52(3/8")(flare) B Service valve connection(liquid side) φ6.35(1/4")(flare) C Pipe/cable draw-out hole D Drain discharge hole φ20 x 3 places E nchor bolt hole M10 x 4 places 103.2 43.5 49.6 286.4 D 50 12 385.9 476 203.1 510 136.9 850 E 14.6 14 312.5 13.5 340 2-16x12 17.9 65 Note (1)It must not be surrounded by walls on four sides. (2)The must be fixed with anchor bolts. n anchor bolt must not protrude more than 15mm. (3)Where the is subjected to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4)Leave 1.2m or more space above the. (5) wall in front of the blower outlet must not exceed the 's height. (6)The model name label is attached on the service panel. L2 Intake Intake Outlet L3 L1 Minimum installation space No obstacles (Service space for electrical parts) 2. EXTERIOR DIMENSIONS Models SCM40ZM-S, 45ZM-S RWC000Z280 640 15 100.3 42.7 211 42.7 Terminal block Service panel 20 20 20 20 B 124.1 34.6 C Dimensions L1 L2 L3 Examples of Installation 600 100 100 Unit:mm '14 SCM-T-167

Symbol Content Service valve connection(gas side) φ9.52(3/8")(flare) B Service valve connection(liquid side) φ6.35(1/4")(flare) C Pipe/cable draw-out hole D Drain discharge hole φ20 x 3 places E nchor bolt hole M10 x 4 places 43.5 286.4 D E 50 12 13.5 Note (1)It must not be surrounded by walls on four sides. (2)The must be fixed with anchor bolts. n anchor bolt must not protrude more than 15mm. (3)Where the is subjected to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4)Leave 1.2m or more space above the. (5) wall in front of the blower outlet must not exceed the 's height. (6)The model name label is attached on the service panel. Models SCM50ZM-S, 60ZM-S - 11-290 103.2 49.6 385.9 476 203.1 510 850 136.9 65 14.6 14 312.5 340 2-16x12 17.9 L2 Intake Intake Outlet L3 L1 Minimum installation space No obstacles (Service space for electrical parts) RWC000Z281 640 15 100.3 42.7 211 42.7 321.7 42.7 Terminal block Service panel 20 20 20 B 20 20 20 124.1 34.6 C Dimensions L1 L2 L3 Examples of Installation 600 100 100 Unit:mm '14 SCM-T-167

Symbol Content Service valve connection(gas side) φ9.52(3/8")(flare) B Service valve connection(liquid side) φ6.35(1/4")(flare) C Pipe/cable draw-out hole D Drain discharge hole φ20 x 3 places E nchor bolt hole M10 x 4 places 47.5 2-R7.5 223 310 E 15 60 Notes (1)It must not be surrounded by walls on four sides. (2)The must be fixed with anchor bolts. n anchor bolt must not protrude more than 15mm. (3)Where the is subjected to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4)Leave 1.2m or more space above the. (5) wall in front of the blower outlet must not exceed the 's height. (6)The model name label is attached on the rear panel. Models SCM71ZM-S, 80ZM-S 340 380 418-12 - RWC000Z277 61 750 24 D 61 150 580 150 26 880 73 110.4 52 20 19 Terminal block B 214.4 52 318.4 52 422.4 52 185 10 L2 Intake C Intake Outlet L3 Dimensions L1 L2 L3 L1 Minimum installation space Examples of Installation 600 100 100 No obstacles (Service space for electrical parts) Unit:mm '14 SCM-T-167

177 15 15 580 970 E Center of gravity 73 Symbol Content Service valve connection(gas side) φ9.52(3/8")(flare) B Service valve connection(liquid side) φ6.35(1/4")(flare) C Pipe/cable draw-out hole D E Drain discharge hole nchor bolt hole φ20 3places M10 4places 26 Terminal block Rear panel Notes (1)It must not be surrounded by walls on the four sides. (2)The must be fixed with anchor bolts. n anchor bolt must not protrude more than 15mm. (3)Where the is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4)Leave 1m or more space above the. (5) wall in front of the blower outlet must not exceed the s height. (6)The model name label is attached on the rear panel. Model SCM100ZM-S 52 B C - 13-20 40 393 115.2 52 219.2 52 531.2 427.2 323.2 945 52 52 RWC000Z278 60 20 410 370 40 55 Center of gravity 190 76 262.8 325 580 D 200 10 L2 L3 Intake L1 Service space 170 Intake Outlet 10 Minimum installation space No obstacles (Service space for electrical parts) Examples of installation Dimensions L1 L2 L3 I Open 300 150 Ⅱ Open 5 300 Ⅲ 500 Open 150 Unit:mm '14 SCM-T-167

177 15 580 970 E 15 Center of gravity 73 Symbol Content Notes Service valve connection(gas side) φ9.52(3/8")(flare) (1)It must not be surrounded by walls on the four sides. B Service valve connection(liquid side) φ6.35(1/4")(flare) (2)The must be fixed with anchor bolts. n anchor bolt must not protrude more than 15mm. C Pipe/cable draw-out hole (3)Where the is subject to strong winds, lay it in such D Drain discharge hole φ20 3places a direction that the blower outlet faces perpendicularly E nchor bolt hole M10 4places to the dominant wind direction. (4)Leave 1m or more space above the. (5) wall in front of the blower outlet must not exceed the s height. (6)The model name label is attached on the rear panel. 26 Terminal block Rear panel Model SCM125ZM-S 52 52 B C - 14-393 945 115.2 52 219.2 52 RWC000Z279 20 40 531.2 427.2 323.2 52 635.2 52 60 20 410 370 40 55 190 76 Center of gravity 262.8 325 580 D 200 10 L2 L3 Intake L1 Service space 170 10 Intake Outlet Minimum installation space No obstacles (Service space for electrical parts) Examples of installation Dimensions L1 L2 L3 I Open 300 150 Ⅱ Open 5 300 Ⅲ 500 Open 150 Unit:mm '14 SCM-T-167

- 15 - Power source 1 Phase C 220 240V 50Hz TB1 L N Y/G TB2 1 UNIT 2 3 TB3 1 UNIT B 2 BR 3 FUSE 250V 15 R IN S IN Y/G G1 Y/G G CN CNB CNHET CN20S PCB 2(SUB) G2 CNEEV1 Y/G RO S O S-1 C-1 CNMIN CN20V CNTH 2 5 2 R S S-2 T1 C-2 T2 CNSUB CN20V U V W PCB 1(MIN) CNFN CNTH 2 2 2 YE OR R M 3~ CM M FM0 Indication lamp Color Function LED e (1) Red Warning lamp Self diagnosis function by led e 1-Time flash Current cut 2-Time flash Trouble of outdoor 3-Time flash Over current 4-Time flash Transmission error 5-Time flash Over heat of compressor 6-Time flash Error of signal transmission 7-Time flash Lock of compressor 8-Time flash Sensor error (Except discharge pipe sensor) Light on Outdoor fan motor error Four sec light and Discharge pipe sensor error four sec off Caution When the compressor does not run Immediately after hitting on the button,wait for 5 to 10 minutes.(there is possibility of delayed start.) High voltage is produced in the control box. don't touch electrical parts in the control box for 5 minutes after cutting power source. 3. ELECTRICL WIRINGS Models SCM40ZM-S, 45ZM-S HETER 20S M EEV M EEV B t t t t Tho-S Tho-R Tho- Tho-D RWC000Z232 Color Marks Mark Color Mark Color Item Black YE Yellow CN-CN20S Red Y/G Yellow/Green 20S White CM OR Orange EEV,EEV B BR Brown FMo HETER Meaning of Marks Description Item Description Connector R Reactor 4 Way valve(coil) TB1-TB3 Terminal block Compressor motor Tho-R Heat exchanger sensor Electric expansion valve (outdoor ) (coil) Tho- Outdoor air temp. sensor Fan motor Tho-D Discharge pipe temp. sensor Crank case heater Tho-S Suction pipe temp. sensor '14 SCM-T-167

- 16 - Power source 1 Phase C 220 240V 50Hz FUSE 250V 15 TB1 250V 20 L R IN N S IN Y G Y G G1 Y G G TB2 1 UNIT 2 3 1 UNIT B 2 BR 3 1 UNIT C 2 BL 3 CN CNB CNC CNHET CN20S R O S O S-1 C-1 CNMIN CN20V PCB 2 SUB G2 CNEEV1 CNEEV3 CNTH Y G 2 BL 5 2 R S S-2 T1 C-2 T2 CNSUB CN20V U V W PCB 1 MIN CNFN CNTH 2 2 2 YE OR R M 3 CM M FMo Indication lamp Color Function LED e 1 Red Warning lamp Self diagnosis function by led e 1-Time flash Current cut 2-Time flash Trouble of outdoor 3-Time flash Over current 4-Time flash Transmission error 5-Time flash Over heat of compressor 6-Time flash Error of signal transmission 7-Time flash Lock of compressor 8-Time flash Sensor error Except discharge pipe sensor Light on Outdoor fan motor error Four sec light and Discharge pipe sensor error four sec off Caution When the compressor does not run Immediately after hitting on the button,wait for 5 to 10 minutes. There is possibility of delayed start. High voltage is produced in the control box. don't touch electrical parts in the control box for 5 minutes after cutting power source. Models SCM50ZM-S, 60ZM-S HETER 20S M M M EEV EEV B EEV C t t t t Tho-S Tho-R Tho- Tho-D RWC000Z252 B Color Marks Mark Color Mark Color Item Black BR Brown CN-CN20S BL Blue YE Yellow 20S Red Y G Yellow Green CM White EEV,EEV B OR Orange EEV C FMo HETER Meaning of Marks Description Item Description Connector R Reactor 4 Way valve coil TB1,TB2 Terminal block Compressor motor Tho-R Heat exchanger sensor Electric expansion valve outdoor coil Tho- Outdoor air temp. sensor Fan motor Tho-D Discharge pipe temp. sensor Crank case heater Tho-S Suction pipe temp. sensor '14 SCM-T-167

- 17 - Power source 1 Phase C 220 240V 50Hz TB1 L N Y G TB2 1 2 UNIT 3 Y G TB3 1 UNIT B 2 BR 3 Y G TB4 1 UNIT C 2 BL 3 Y G TB5 1 UNIT D 2 YE 3 Y G FUSE 250V 20 Y G R IN S IN Y G G1 Y G G CN CNB CNC CND CNHET CN20S PCB 2 SUB G2 Y G CNEEV1 CNEEV2 BL GN R O S O S-1 C-1 CNMIN CN20V CNTH 2 5 2 R S S-2 T1 C-2 T2 CNSUB CN20V U V W PCB 1 MIN CNFN CNTH 2 2 2 YE OR R M 3 CM M FMo Indication lamp Color Function LED e 1 Red Warning lamp Self diagnosis function by led e 1-Time flash Current cut 2-Time flash Trouble of outdoor 3-Time flash Over current 4-Time flash Transmission error 5-Time flash Over heat of compressor 6-Time flash Error of signal transmission 7-Time flash Lock of compressor 8-Time flash Sensor error Except discharge pipe sensor Light on Outdoor fan motor error Four sec light and Discharge pipe sensor error four sec off Caution When the compressor does not run Immediately after hitting on the button,wait for 5 to 10 minutes. There is possibility of delayed start. High voltage is produced in the control box. don't touch electrical parts in the control box for 5 minutes after cutting power source. Models SCM71ZM-S, 80ZM-S HETER 20S M M M M EEV EEV EEV EEV B C D t Tho-S t t t Tho-R Tho- Tho-D RWC000Z250 B Color Marks Mark Color Mark Color Item Black Red CN-CN20S BL Blue White 20S BR Brown YE Yellow CM GN Green Y G Yellow Green EEV,EEV B OR Orange EEV C,EEV D FMo HETER Meaning of Marks Description Item Description Connector R Reactor 4 Way valve coil TB1 5 Terminal block Compressor motor Tho-R Heat exchanger sensor Electric expansion valve outdoor coil Tho- Outdoor air temp. sensor Fan motor Tho-D Discharge pipe temp. sensor Crank case heater Tho-S Suction pipe temp. sensor '14 SCM-T-167

t t t t t - 18 - RWC000Z276 Power source 1 Phase C 220 240V 50Hz TB1 F 1 L 30 250V TB3 TB5 PCB5 N NOISE TB4 TB6 Y/G FILTER 3 TB7 TB8 UNIT UNIT B UNIT C UNIT D UNIT E TB2 1 2 3 1 2 3 1 2 3 TB3 1 2 3 1 2 3 BR BL Y OR CN () CNB () CNC () CND () CNE () CN EEV1 () Y/G Y/G CN CN EEV2 EEV3 () () 5 5 5 5 5 BL GN 5 5 5 5 5 1.Instructions for correct operation Before you turn on power,please carefully read the installation manual and the operation manual supplied with the. Please check the following points before operation. 1 This is designed exclusively for use with R410. Do not use any refrigerant other than R410. 2 To protect the compressor,turn on power for the air conditioner 6 hours before operation so as warm up sufficiently the dome temperature of compressor. 3 Open the service valves of liquid pipe at first. Secondarily open the one of gas pipe. Before you operate the,make sure again that the service valves are in open position. 4 Please note that the pressure valves detected at the charge port in the and the gas service valves are different during the cooling operation and the heating operation. High pressure is replaced with the low pressure depending on whether it is in the cooling or heating operation. M EEV M EEV B M EEV C M EEV D M EEV E TB3 TB4 TB5 PCB3 NOISE FILTER TB6 TB7 Y/G L-IN N-IN CNTRI 2 () 2 CNTRO TR CNW () () PCB4 CNS2 CNS1 () () SUB PCB CNX2 CNX1 (Y) (Y) G Y/G CNTH 2 +1 ~ CDS 3 ~ -4 CT1 CNP1 2 2 2 2 2 2.Error indication Y Tho-R Tho-D Tho-S Tho- Tho-F PCB1 CONTROL PCB BL CN EEV1 () 5 M EEV-H P1 1 2 P2 N1 4 3 N2 CNL1 (BL) INDICTION LMP COLOR FUNCTION LED E (1) RED WRNING LMP SELF DIGNOSIS FUNCTION BY LED E 1-TIME FLSH CURRENT CUT 2-TIME FLSH TROUBLE OF OUTDOOR UNIT 3-TIME FLSH OVER CURRENT 4-TIME FLSH TRNSMISSION ERROR 5-TIME FLSH OVER HET OF COMPRESSOR 6-TIME FLSH ERROR OF SIGNL TRNSMISSION 8-TIME FLSH SENSOR ERROR (EXCEPT DISCHRGE PIPE SENSOR) LIGHT ON OUTDOOR FN MOTOR ERROR FOUR SEC LIGHT ND DISCHRGE PIPE SENSOR ERROR FOUR SEC OFF 3 LED2 CHECKER CNE 5 BL LED1 LED3 PC CNV CN FN1 CNR1 () () BR HPS M CH 20S FM 2 L + L1 L2 4 CNCT1 CNCT () () - P P3 /F + MODULE N2 BLC1 BL N3 CN1 () CN2 (GN) CNI1 () CNI3 () CNN1 () BL 2 BL 4 3 F2 4 250V BL BL CNI2 CNI4 IPM 30 600V W BL PCB2 INV PCB V V W MS CM 3~ Note(1) used only at our factory. U U Mark /F MODULE CH CM CN-Z CT DS EEV EEV-H F FM HPS IPM L LED1 LED2 LED3 TB Tho- Tho-D Tho-R Tho-S Tho-F TR 20S Mark BL BR GN OR PK Y Y/G Name ctive filter module Crankcase heater Compressor motor Connector Current sensor Diode stack Electronic expansion coil Electronic expansion coil(for heating) Fuse Fan motor High pressure sensor Intelligent power module Reactor Indicator lamp(red-inspection indicator) Indicator lamp(green-microcomputer normality indicator) Indicator lamp(green-for service) Terminal block Thermistor(outdoor air temperature) Thermistor(discharge pipe) Thermistor(heat exchanger) Thermistor(suction pipe) Thermistor(power transistor) Trance former 4-way valve coil Color Black Blue Brown Green Orange Pink Red White Yellow Yellow/Green Model SCM100ZM-S '14 SCM-T-167

t t t t t - 19 - RWC000Z244 B Power source 1 Phase C 220 240V TB1 F 1 50Hz L 30 250V TB3 TB5 PCB5 N NOISE Y/G TB4 FILTER TB6 3 TB7 TB8 UNIT UNIT B UNIT C UNIT D UNIT E UNIT F TB2 Y/G Y/G TB3 TB4 TB5 PCB3 NOISE FILTER TB6 TB7 Y/G 2 +1 ~ CDS 3-4 ~ CT1 1 L-IN N-IN CNW CN 2 () 3 () CNTRI 2 1 CNB () 2 2 CNTRO TR BR 3 () () 1 CNC 2 CNS2 BL 3 () CNS1 PCB4 () () PCB1 TB3 SUB PCB CONTROL PCB 1 CND CNX2 2 Y CNX1 3 () (Y) (Y) Y/G 1 CNE G 2 OR 3 () 1 CNF CN CN CN EEV1 EEV2 EEV3 EEV4 CN CN 2 PK () EEV1 3 () () ()() CNTH CNP1 () 5 5 5 5 5 5 2 2 2 2 2 5 BL GN Y 5 5 5 5 5 5 1.Instructions for correct operation Before you turn on power,please carefully read the installation manual and the operation manual supplied with the. Please check the following points before operation. 1 This is designed exclusively for use with R410. Do not use any refrigerant other than R410. 2 To protect the compressor,turn on power for the air conditioner 6 hours before operation so as warm up sufficiently the dome temperature of compressor. 3 Open the service valves of liquid pipe at first. Secondarily open the one of gas pipe. Before you operate the,make sure again that the service valves are in open position. 4 Please note that the pressure valves detected at the charge port in the and the gas service valves are different during the cooling operation and the heating operation. High pressure is replaced with the low pressure depending on whether it is in the cooling or heating operation. M EEV M EEV B M EEV C M EEV D M EEV E M EEV F 2.Error indication Y Tho-R Tho-D Tho-S Tho- Tho-F BL M EEV-H P1 1 2 P2 N1 4 3 N2 CNL1 (BL) INDICTION LMP COLOR FUNCTION LED E (1) RED WRNING LMP SELF DIGNOSIS FUNCTION BY LED E 1-TIME FLSH 2-TIME FLSH CURRENT CUT TROUBLE OF OUTDOOR UNIT 3-TIME FLSH 4-TIME FLSH OVER CURRENT TRNSMISSION ERROR 5-TIME FLSH 6-TIME FLSH OVER HET OF COMPRESSOR ERROR OF SIGNL TRNSMISSION 8-TIME FLSH SENSOR ERROR (EXCEPT DISCHRGE PIPE SENSOR) LIGHT ON OUTDOOR FN MOTOR ERROR FOUR SEC LIGHT ND DISCHRGE PIPE SENSOR ERROR FOUR SEC OFF 3 LED2 CHECKER CNE 5 BL LED1 LED3 PC CNV CN FN1 CNR1 () () BR HPS M CH 20S FM 2 L 4 + L1 L2 CNCT1 CNCT () () - P P3 /F + MODULE N2 BLC1 BL N3 CN1 () CN2 (GN) CNI1 () CNI3 () CNN1 () BL 2 BL 4 3 F2 4 250V BL BL CNI2 CNI4 IPM 30 600V W V U BL Note(1) used only at our factory. PCB2 INV PCB V W CM MS 3~ U Mark Name /F MODULE ctive filter module CH Crankcase heater CM CN-Z CT Compressor motor Connector Current sensor DS EEV Diode stack Electronic expansion coil EEV-H Electronic expansion coil(for heating) F Fuse FM Fan motor HPS High pressure sensor IPM Intelligent power module L Reactor LED1 Indicator lamp(red-inspection indicator) LED2 Indicator lamp(green-microcomputer normality indicator) LED3 Indicator lamp(green-for service) TB Terminal block Tho- Thermistor(outdoor air temperature) Tho-D Thermistor(discharge pipe) Tho-R Thermistor(heat exchanger) Tho-S Thermistor(suction pipe) Tho-F Thermistor(power transistor) TR Trance former 20S 4-way valve coil Mark Color Black BL Blue BR Brown GN Green OR Orange PK Pink Red White Y Yellow Y/G Yellow/Green Model SCM125ZM-S '14 SCM-T-167

4. TECHNICL INFORMTION (1) Model SCM40ZM-S Indoor model name SRK20ZMX-S x 2 information relates to. Indicated values should relate to one Outdoor model name SCM40ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 4.00 kw cooling SEER 5.92 + heating / verage Pdesignh 5.20 kw heating / verage SCOP/ 4.05 + heating / verage (-10 ) Pdh 4.41 kw heating / verage (-10 ) elbu 0.79 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 4.00 kw Tj=35 EERd 4.76 - Tj=30 Pdc 3.00 kw Tj=30 EERd 7.20 - Tj=25 Pdc 3.30 kw Tj=25 EERd 8.90 - Tj=20 Pdc 3.60 kw Tj=20 EERd 7.40 - Tj=-7 Pdh 4.60 kw Tj=-7 COPd 2.80 - Tj=2 Pdh 2.80 kw Tj=2 COPd 3.90 - Tj=7 Pdh 2.20 kw Tj=7 COPd 5.50 - Tj=12 Pdh 3.10 kw Tj=12 COPd 6.90 - Tj=bivalent temperature Pdh 4.60 kw Tj=bivalent temperature COPd 2.80 - Tj=operating limit Pdh 4.10 kw Tj=operating limit COPd 2.50 - off mode Poff 13 W cooling Qce 237 kwh/a standby mode Psb 13 W heating / verage Qhe 1798 kwh/a thermostat-off mode Pto 25 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 53 db() Sound power level(outdoor) Lwa 60 db() staged No Rated air flow(indoor) - 690 m3/h variable Yes Rated air flow(outdoor) - 2400 m3/h - 20 -

Indoor model name SRK20ZM-S x 2 information relates to. Indicated values should relate to one Outdoor model name SCM40ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 4.00 kw cooling SEER 5.72 + heating / verage Pdesignh 5.20 kw heating / verage SCOP/ 3.84 heating / verage (-10 ) Pdh 4.41 kw heating / verage (-10 ) elbu 0.79 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 4.00 kw Tj=35 EERd 4.54 - Tj=30 Pdc 3.00 kw Tj=30 EERd 6.90 - Tj=25 Pdc 3.30 kw Tj=25 EERd 8.50 - Tj=20 Pdc 3.60 kw Tj=20 EERd 7.20 - Tj=-7 Pdh 4.60 kw Tj=-7 COPd 2.60 - Tj=2 Pdh 2.80 kw Tj=2 COPd 3.60 - Tj=7 Pdh 2.20 kw Tj=7 COPd 5.50 - Tj=12 Pdh 3.10 kw Tj=12 COPd 6.90 - Tj=bivalent temperature Pdh 4.60 kw Tj=bivalent temperature COPd 2.60 - Tj=operating limit Pdh 4.10 kw Tj=operating limit COPd 2.40 - off mode Poff 13 W cooling Qce 245 kwh/a standby mode Psb 13 W heating / verage Qhe 1897 kwh/a thermostat-off mode Pto 25 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 49 db() Sound power level(outdoor) Lwa 60 db() staged No Rated air flow(indoor) - 468 m3/h variable Yes Rated air flow(outdoor) - 2400 m3/h - 21 -

(2) Model SCM45ZM-S Indoor model name SRK20ZMX-S + SRK25ZMX-S information relates to. Indicated values should relate to one Outdoor model name SCM45ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 4.50 kw cooling SEER 5.98 + heating / verage Pdesignh 5.80 kw heating / verage SCOP/ 4.03 + heating / verage (-10 ) Pdh 4.95 kw heating / verage (-10 ) elbu 0.85 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 4.50 kw Tj=35 EERd 4.33 - Tj=30 Pdc 3.30 kw Tj=30 EERd 7.00 - Tj=25 Pdc 3.30 kw Tj=25 EERd 8.90 - Tj=20 Pdc 3.60 kw Tj=20 EERd 7.40 - Tj=-7 Pdh 5.10 kw Tj=-7 COPd 2.40 - Tj=2 Pdh 3.10 kw Tj=2 COPd 4.00 - Tj=7 Pdh 2.20 kw Tj=7 COPd 5.50 - Tj=12 Pdh 3.10 kw Tj=12 COPd 6.90 - Tj=bivalent temperature Pdh 5.10 kw Tj=bivalent temperature COPd 2.40 - Tj=operating limit Pdh 4.70 kw Tj=operating limit COPd 2.10 - off mode Poff 13 W cooling Qce 264 kwh/a standby mode Psb 13 W heating / verage Qhe 2014 kwh/a thermostat-off mode Pto 25 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 55 db() Sound power level(outdoor) Lwa 60 db() staged No Rated air flow(indoor) - 750 m3/h variable Yes Rated air flow(outdoor) - 2400 m3/h - 22 -

Indoor model name SRK20ZM-S+SRK25ZM-S information relates to. Indicated values should relate to one Outdoor model name SCM45ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 4.50 kw cooling SEER 5.80 + heating / verage Pdesignh 5.80 kw heating / verage SCOP/ 3.82 heating / verage (-10 ) Pdh 4.95 kw heating / verage (-10 ) elbu 0.85 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 4.50 kw Tj=35 EERd 4.12 - Tj=30 Pdc 3.30 kw Tj=30 EERd 6.85 - Tj=25 Pdc 3.30 kw Tj=25 EERd 8.50 - Tj=20 Pdc 3.60 kw Tj=20 EERd 7.20 - Tj=-7 Pdh 5.10 kw Tj=-7 COPd 2.30 - Tj=2 Pdh 3.10 kw Tj=2 COPd 3.65 - Tj=7 Pdh 2.20 kw Tj=7 COPd 5.50 - Tj=12 Pdh 3.10 kw Tj=12 COPd 6.85 - Tj=bivalent temperature Pdh 5.10 kw Tj=bivalent temperature COPd 2.30 - Tj=operating limit Pdh 4.70 kw Tj=operating limit COPd 2.10 - off mode Poff 13 W cooling Qce 272 kwh/a standby mode Psb 13 W heating / verage Qhe 2128 kwh/a thermostat-off mode Pto 25 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 50 db() Sound power level(outdoor) Lwa 60 db() staged No Rated air flow(indoor) - 474 m3/h variable Yes Rated air flow(outdoor) - 2400 m3/h - 23 -

(3) Model SCM50ZM-S Indoor model name SRK25ZMX-S 2 information relates to. Indicated values should relate to one Outdoor model name SCM50ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 5.00 kw cooling SEER 5.61 + heating / verage Pdesignh 5.80 kw heating / verage SCOP/ 3.82 heating / verage (-10 ) Pdh 4.90 kw heating / verage (-10 ) elbu 0.90 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 5.00 kw Tj=35 EERd 3.70 - Tj=30 Pdc 3.70 kw Tj=30 EERd 5.75 - Tj=25 Pdc 3.30 kw Tj=25 EERd 8.15 - Tj=20 Pdc 3.60 kw Tj=20 EERd 7.40 - Tj=-7 Pdh 5.20 kw Tj=-7 COPd 2.50 - Tj=2 Pdh 3.20 kw Tj=2 COPd 3.71 - Tj=7 Pdh 2.10 kw Tj=7 COPd 5.20 - Tj=12 Pdh 2.30 kw Tj=12 COPd 5.90 - Tj=bivalent temperature Pdh 5.20 kw Tj=bivalent temperature COPd 2.50 - Tj=operating limit Pdh 4.40 kw Tj=operating limit COPd 1.90 - off mode Poff 12 W cooling Qce 312 kwh/a standby mode Psb 12 W heating / verage Qhe 2125 kwh/a thermostat-off mode Pto 30 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 50 db() Sound power level(outdoor) Lwa 62 db() staged No Rated air flow(indoor) - 474 m3/h variable Yes Rated air flow(outdoor) - 2460 m3/h - 24 -

Indoor model name SRK20ZMX-S x 3 information relates to. Indicated values should relate to one Outdoor model name SCM50ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 5.00 kw cooling SEER 6.62 ++ heating / verage Pdesignh 5.90 kw heating / verage SCOP/ 3.95 heating / verage (-10 ) Pdh 4.90 kw heating / verage (-10 ) elbu 1.00 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 5.00 kw Tj=35 EERd 4.63 - Tj=30 Pdc 3.70 kw Tj=30 EERd 7.10 - Tj=25 Pdc 3.60 kw Tj=25 EERd 9.90 - Tj=20 Pdc 3.90 kw Tj=20 EERd 9.00 - Tj=-7 Pdh 5.20 kw Tj=-7 COPd 2.60 - Tj=2 Pdh 3.20 kw Tj=2 COPd 3.90 - Tj=7 Pdh 2.00 kw Tj=7 COPd 5.10 - Tj=12 Pdh 2.30 kw Tj=12 COPd 6.30 - Tj=bivalent temperature Pdh 5.20 kw Tj=bivalent temperature COPd 2.60 - Tj=operating limit Pdh 4.40 kw Tj=operating limit COPd 2.20 - off mode Poff 13 W cooling Qce 265 kwh/a standby mode Psb 13 W heating / verage Qhe 2091 kwh/a thermostat-off mode Pto 28 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 53 db() Sound power level(outdoor) Lwa 62 db() staged No Rated air flow(indoor) - 690 m3/h variable Yes Rated air flow(outdoor) - 2460 m3/h B - 25 -

Indoor model name SRK25ZM-S 2 information relates to. Indicated values should relate to one Outdoor model name SCM50ZM-S heating season at a time. Include at least the heating season 'verage'. Item symbol value Item symbol value class cooling Pdesignc 5.00 kw cooling SEER 5.60 + heating / verage Pdesignh 6.10 kw heating / verage SCOP/ 3.80 heating / verage (-10 ) Pdh 5.14 kw heating / verage (-10 ) elbu 0.96 kw Declared capacity for cooling, at indoor temperature 27(19) and Declared energy efficiency ratio, at indoor temperature 27(19) and Tj=35 Pdc 5.00 kw Tj=35 EERd 3.40 - Tj=30 Pdc 3.70 kw Tj=30 EERd 5.70 - Tj=25 Pdc 3.30 kw Tj=25 EERd 8.10 - Tj=20 Pdc 3.60 kw Tj=20 EERd 7.40 - Tj=-7 Pdh 5.40 kw Tj=-7 COPd 2.40 - Tj=2 Pdh 3.30 kw Tj=2 COPd 3.73 - Tj=7 Pdh 2.20 kw Tj=7 COPd 5.20 - Tj=12 Pdh 2.80 kw Tj=12 COPd 5.90 - Tj=bivalent temperature Pdh 5.40 kw Tj=bivalent temperature COPd 2.40 - Tj=operating limit Pdh 4.70 kw Tj=operating limit COPd 1.90 - off mode Poff 11 W cooling Qce 313 kwh/a standby mode Psb 11 W heating / verage Qhe 2247 kwh/a thermostat-off mode Pto 25 W heating / Warmer Qhe - kwh/a Sound power level(indoor) Lwa 50 db() Sound power level(outdoor) Lwa 62 db() staged No Rated air flow(indoor) - 474 m3/h variable Yes Rated air flow(outdoor) - 2460 m3/h - 26 -