S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

Similar documents
S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

CLE SERIES Fluid heating for emergency eyewash stations

C1N & C2N SERIES Fluid heating for light industrial applications

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

HL SERIES Fluid heating for commercial applications

KELTECH ELECTRIC TANKLESS WATER HEATERS. Fluid heating for commercial, industrial and safety applications PRECISE. RELIABLE. DURABLE. TANKLESS.

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

Installation Keltech S19361 Heater Safety Fixture Skid Keltech S19361F Freeze Protected Heater Safety Fixture Skid

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Industrial Solutions. Plumbing Fixtures, Safety Fixtures & Locker Rooms BRADLEYCORP.COM

ASME Packaged Electric Water Heater

Tepid Water Delivery System

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Installation. Keltech S194 Series. Tankless Water Heating Solutions. Table of Contents

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

8200 Combination Units

Tankless On Demand Electric Water Heater

Control and power circuit fusing to meet N.E.C.

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

DIVISION FINNED WATER-TUBE BOILERS

Eyewash and Eye/Face Wash units that are either wall mounted or pedestal mounted. 7260B B 7270B

SECTION DOMESTIC WATER HEATERS

TEMPERED WATER. Solutions for Safety Showers

Installation Keltech C2N Series Tankless Heater Models

OPERATING AND MAINTENANCE MANUAL FOR ELECTRIC STAINLESS STEEL HEATER FOR DEIONIZED (DI) WATER ELECTRIC HEATER COMPANY BASE MODEL D

Installation, Operation and Maintenance Instructions

CAPABILITIES BROCHURE

DIVISION FINNED WATER-TUBE BOILERS

ULTRA-SAFE Explosion-proof Duct Heaters

Suggested Specifications Prestige Excellence 110

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

SECTION ROTARY-SCREW WATER CHILLERS

Light Duty Commercial Electric Water Heater

Commercial Electric Water Heater Gallon Capacity, up to 58 KW in all Three Phase Voltages, Over 6 KW in all Single Phase Voltages

ECONOMICAL, EFFICIENT PERFORMANCE

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Circulation Heaters Selection Guidelines

PRO SERIES IMPORTANT SAFETY INFORMATION

INSTANT-FLOW C-MICRO WATER HEATER

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

RHP120 RHP300 Steam Boiler Series

INSTALLATION AND SERVICE MANUAL

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

POINT-OF-USE WATER HEATERS

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

ULTRA-SAFE Explosion-proof Duct Heaters

Automatic Temperature Controller (ATC)

INSTANT-FLOW C-MICRO WATER HEATER

Call us today! (800)

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric

Indirect Fired Water Heater

DIVISION FINNED WATER-TUBE WATER HEATERS

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

HEATING WATER FOR OVER 50 YEARS

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

FINNED WATER-TUBE POOL HEATERS

Circulation Heaters Selection Guidelines

EMERGENCY EQUIPMENT AXION MSR MEDICALLY SUPERIOR RESPONSE PRODUCTS EYE/FACE WASH :: SHOWERS COMBINATION UNITS

OPERATION & INSTALLATION MANUAL IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, IR-18K220. Electric Tankless Hot Water Heater

Revitalize Building Mechanical Systems (4619)

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

ENGINEERED DUPLEX ALLOY

OPERATING AND MAINTENANCE MANUAL FOR PACKAGED ELECTRIC TEPID WATER HEATING SYSTEMS BASE MODEL ESS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

DIVISION FINNED WATER-TUBE WATER HEATERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

Shipboard Electric Water Heater

Shipboard Electric Water Heater

INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR COMMERCIAL INDIRECT POWERED WATER HEATER

WATER-TUBE POOL HEATERS

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Electric Coils. Blower Coils. Product Information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Circulating Water Temperature Controller

Electric Tankless Water Heaters

Transcription:

Pre-assembled, freeze-protected safety fixture and SNA heater skid system Bradley Heat Trace S19-304 with SpinTec 54-144 kw (491,300 BTUs) Molded Duragrate and integrated shower pan Temperature overshoot purge system NEMA 4 enclosure standard AL3 building communication alarm option included Dual Flow Heater Activation (Eye/Face Wash and/or Shower) Internal fusing (included) adds safety and permits single power connection Controller-locked temperature setting, output fixed at 80 F (27 C) Meets ANSI/ISEA Z358.1 standards Emergency stop button and door cutoff switch Standard Heater Equipment Tankless Water Heating Specifications Keltech, Inc. SNA Safety Shower Heaters provide warm water intended to supply safety fixtures. The heaters uniquely perform in applications with low line pressure, while still accommodating ANSI standard flow rates. The durable components withstand higher pressures which result in longer service life, while ensuring the delivery of precise output temperature. Keltech's durable components withstand power abnormalities found in industrial environments and ensure tepid water standards are never exceeded (100 F) with it's three-tier anti-scald protection and hot water purge. SNA-Series units are also suited to applications with 3 Phase Delta 480V or 600V, 50/60 Hz. The heat exchanger features o-ring seals that out last typical gasket construction. 1-1/4" NPT female inlet and outlet connections. Construction Skid Skid includes freeze-protected skid with pre-piped assemblies, 1-1/4" inlet, pre-piped pressure and temperature relief valve and piping connecting the heater to the safety shower and eye/face wash combination unit. Skid is #10 gauge electro galvanized sheet steel frame, powder painted "safety yellow." Square molded Duragrate fiberglass (1" x 1-1/2" x 1-1/2") grating with grit top, covers the integrated shower pan. Temperature Controller Keltech's PID Temperature Controller is more energy efficient and reliable than traditional microprocessors using staged elements. Power is infinitely variable, with no fixed inputs. The PID controller makes it possible to modulate the amount of power applied to the elements while also dispersing the required power evenly across all elements. This unique feature increases the product's life cycle. Heating Element Each heater features a heavy duty, low watt density, Incoloy 800 sheathed resistive element. The Keltech design ensures greater protection, durability and resistance to scaling from hard water because water is only heated when flowing; this means sediment will not collect in the heat exchanger. Solid State Relays The liquid cooled solid state relays provide silent switching, which has a fast response and works in conjunction with the PID controller to infinitely modulate and add to the life of the heater. Electrical The SNA-Series requires only one service feed per unit. Includes internal fusing as standard. Internal fusing provides superior protection so the incoming circuit can be higher than 48 amps (NEC). Keltech protects each heating element with fusing. Cabinet Enclosure The skid-mounted cabinet enclosure is NEMA 4 rated and made from 14 gauge mild steel and powder coated with ANSI 61 gray, corrosion resistant paint. The optional NEMA 4X enclosures are corrosion resistant for harsher environments and made from 16 gauge 304 stainless steel. The NEMA 4X enclosure can also be specified with 316 stainless steel. Additional service access panel located on top of cabinet enclosure. Page 1 of 7 12/18/2017 Independent Safeties Heater has three-tier anti-scald protection and TepiGuard hot water evacuation (overshoot purge protection). The controller alarm sends a signal to disconnect power to the elements if the temperature reaches 90 F (32 C). The internal thermostat with auto reset high limit switch ensures that when the temperature limit is reached, the unit will power down a bank of elements; when the temperature returns to the set point, power is restored. The surface mounted bi-metal thermostat with manual reset acts as a fail-safe and must be manually reset before power can be restored to the elements if the temperature limit is exceeded. TepidGuard is an anti-scald feature, standard on all SNA-Series Safety Shower Heaters. This overshoot purge will automatically open and purge excess temperature water. This feature actively monitors temperature within the heater while operational. It also passively monitors water temperature while the heater is inactive. This is beneficial for outdoor installations where sun and weather can cause water temperature to exceed ANSI standards. Temperature Safety Values: Internal thermostat with auto reset high limit switch: 95 F (35 C) Surface mounted bi-metal thermostat with manual reset: 100 F (38 C) Overshoot purge: 95 F (35 C) S19361HF Dual Flow Activation Keltech Safety Shower heaters have a dual flow activation. The low flow activation is used with eyewashes, eye/face washes, and drench hoses. The high flow activation is for safety shower usage. This allows just the right capacity of heated water to be used for each application. Heater operating range is 30-150 psi. Standard Safety Fixture Equipment Bradley S19-304 Heat Trace Safety Shower mounted to skid provides a superior washdown with a more even spray pattern. Combination shower and eye/face wash unit is intended for use in areas where temperatures fall below freezing. Heat trace cable protects unit from freezing. Unit is encased in highly visible yellow ABS removable plastic shell. Shower valve operates quickly by a pull rod with a triangular handle and provides superior washdown. Halo eye/face wash is operated by a universal push handle. SpinTec Showerhead Showerhead is 3.1" (78.7mm) diameter highly visible yellow impact-resistant plastic. SpinTec drench shower's head features integral 22 GPM (83.3 L) flow control (exceeds minimum water flow of 20 GPM (75.7 L) at 30 psi (2.0 bar)), conserving water, allowing you to accurately size your S19361HF skid system. Bowl and Dust Cover Bowl and dust cover are constructed of yellow impact-resistant plastic. Dust cover is transparent. Protected by one or more of the following patents: 7,007,316 B2; 7,243,381 B2.

Eye/Face Wash The Halo eye/face wash system offers a high performance rinsing platform that provides rapid relief to an individual's eyes and face that have been injured by chemicals or particulate. This system provides the most ocmplete face wash available in the market. The eye/face wash includes an integral 5.1 GPM (19.2 LPM) flow control, providing water at a safe velocyty while maintaining its effectiveness (exceeds minimum water flow of 3.0 GPM (11.4 LPM) at 30 PSI (2.0 bar)). Safe, steady water flow under carying water supply conditions from 30-90 PSI (2.0-6.1 bar) is assured by integral flow control in the sprayhead assembly. Sprayheads are made from an impact resistant ABS plastic. Halo is covered by one or more of the following patents: 9,700,484; 9,314,398; D662220; D673298; D662605; D685920; D662219; and D671228. Other patents pending. Heater Product Options Fused Disconnect Internal fused disconnect interlocks with enclosure door when energized, prohibiting access to a live cabinet. Select the FDS option for an additional level of safety and convenience at the heater location. Not available with SNA-723/600D. Alarm Selections Keltech offers two levels of building communication alarm options. The AL3 option comes standard on the S19361F and provides dry contacts that open to signal flow >1.5 gpm has activated the heater. The AL3-SL option provides these dry contacts and additionally activates a local audible and visual alarm on the heater. Alarms activate at 1.5 gpm flow or greater. Freeze Protection The S19361F includes heater with ENHT which offers protection to -20 F (-28 C). The ENHT30 option offers protection to -30 F (-34 C). Each level of protection utilizes the normal heater supply voltage. No additional dedicated circuit to the unit is required during field installation. Freeze protection (ENHT and ENHT30 options) include an internally insulated NEMA 4/4X enclosure and thermostatically controlled forced air heater to maintain internal temperatures above freezing. Freeze protection options also include a connection point for DCS monitoring. IN the event of a power interruption or ENHT system failure when internal enclosure temperatures reach 40 F (4.4 C) or lower, the unit will notify a facilities control/ monitoring system that the unit is unable to maintain freeze protection. Regardless of state of power to the unit, this warning notifies maintenance personnel and provides an opportunity to correct the condition before any damage occurs to the unit. Ground Fault Optional equipment protection ground fault senses leakage current to ground >1 Amp. In the event a fault is detected, this device will terminate the high voltage power supply to heating elements and disable operation of the unit. Fault status is communicated EXTERNALLY at the control interface. Personnel may also test the Ground Fault system and reset any nuisance trips without opening the cabinet. Continuous Flow Explosion Proof Purge System Keltech's EXP2CFPM option makes heaters compliant for classified areas; Class 1, Division 2, Groups A-D, T5. The Purge System requires a supply of clean instrument air or inert gas (provided by installer). This supply maintains a positive internal pressure and prevents the enclosure from filling with flammable gasses, dusts or vapors from the ambient environment. In addition to manufacturer certifications on the purge system, Keltech independently tests and 3rd party certifies all finished product with EXP2CFPM to comply with NFPA 496. ASME Heat Exchanger Keltech offers any product above 200,000 btu equivalent (58kw+) the option to be fitted with internal plumbing certified to Section IV of the ASME Boiler and Pressure Vessel Code - an industry exclusive certification. HLW certification represents not only an approved design and method of construction, but an intensively audited construction and documentation process that concludes with a pressure test witnessed by an ASME official. Upon completion of this process, each heat exchanger is issued a unique serial number for registration in the National Board. This information is supplied with the unit via Form "HLW-6 Manufacturer Data Report" for verification and reference by local inspection officials. The HLW options also include additional features such as dry-fire protection, stainless steel bulkheads and boiler drain valves, adding an extra level of quality and durability to Keltech heaters. Other Product Options For additional heater options and installation accessories, reference the appropriate section at the end of this document. Page 2 of 7 12/18/2017 Heater Code Compliance and Certifications Certified to NSF/ANSI 372 Lead-Free Products marked with the Lead-Free logo comply with the Safe Drinking Water Act (SDWA) requirements of a weighted average of less than 0.25% lead content on wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures. ETL listed to UL499 ETL listed to UL 50E ETL listed to NFPA 496 (Requires EXP2CFPM Option) cetl listed to CSA-C22.2 No. 88 Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. ASME Certification available. Keltech units 58kW (200,000 btu) and higher are the only electric tankless water heaters National Board certified with the HLW stamp (Requires HLW Option). Safety Shower Code Compliance and Certifications

Electrical Specifications for the Heater (3-Phase) All internal fuses necessary for installation are included with the unit. S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Capacity (kw) Voltage Maximum Amperage Minimum AWG Wire Size 54 480 65 4 54 600 52 6 63 480 76 4 63 600 61 4 72 480 87 3 72 600 69 4 108 480 132 1 108 600 104 2 126 480 152 1/0 126 600 121 1 144 480 174 2/0 144 600 139 1/0 S19361HF Series Pressure Drop Advantage GPM 1.5 2 3 4 5 6 8 10 15 20 25 30 35 40 45 50 54 63 kw PSI 72 144 kw PSI 0.0 0.0 0.1 0.2 0.2 0.3 0.6 0.9 2.0 3.6 5.5 7.9 10.8 14.0 17.6 21.7 0.0 0.0 0.1 0.2 0.3 0.4 0.8 1.2 2.6 4.7 7.3 10.4 14.2 18.5 23.3 28.7 L-MIN 5.7 7.6 11.3 15.1 18.9 22.7 30.2 37.8 56.7 75.6 94.5 113.4 132.5 151.2 170.1 189 54 63 kw BAR 72 144 kw BAR 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.4 0.5 0.7 1.0 1.2 1.5 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.5 0.7 1.0 1.3 1.6 2.0 Page 3 of 7 12/18/2017

S19361HF Series - Dimensions Select product options shown. Other options available. (mm) Front View Temperature and Pressure Relief Valve Right Side View Optional Stack Light Shower Pull Rod Protective Partition Heat Trace Shower with Eye/Face Wash 86" (2183) 103-1/4" (2620) 35-3/4" (910) Skid Platform 46" (1168) 6" (152) Page 4 of 7 12/18/2017

S19361HF Series - Dimensions Back View Select product options shown. Other options available. Heat Trace Thermostat (mm) Insulating Wrap Around Piping Temperature Display and Heater Controls Tankless Water Heater Emergency Stop TepidGuard Discharge (Drain) 1-1/4" NPT Female Inlet 8-1/8" (205) Dim. "A" 54kW 34-1/2" (876) 63kW 46-1/2" (1180) 72kW 34-1/2" (876) A 108kW 34-1/2" (876) 126kW 46-1/2" (1180) To Drain 144kW 46-1/2" (1180) Forklift Slots (25" deep) 24" (610) ø 3-1/2" (3" nominal) PVC Drain Connection 2-1/2" (67) Top View 8-1/2" (217) Mounting Flanges (4 places) 49" (1245) ø 5/8" (16) (4 places) 1-1/8" (29) 52" (1321) 48" (1219) 50-1/4" (1276) 9-1/2" (243) Page 5 of 7 12/18/2017 44-3/4" (1138) 66" (1678)

Heater kw Calculator SNA-Series (kw): 54, 63, 72, 108, 126, 144 Flow Temperature Δ F ( C) 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 120 125 130 135 140 GPM L-MIN (6 ) (8 ) (11 ) (14 ) (17 ) (19 ) (22 ) (25 ) (28 ) (31 ) (33 ) (36 ) (39 ) (42 ) (44 ) (47 ) (50 ) (53 ) (56 ) (58 ) (61 ) (64 ) (67 ) (69 ) (72 ) (75 ) (78 ) 2 7.6 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 3 11.3 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 63 63 63 63 4 15.1 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 54 63 63 72 72 72 108 108 108 108 5 18.9 54 54 54 54 54 54 54 54 54 54 54 54 54 54 63 63 72 72 108 108 108 108 108 108 108 108 108-6 22.7 54 54 54 54 54 54 54 54 54 54 54 63 63 72 72 108 108 108 108 108 108 108 108 126 126 126 126 7 26.5 54 54 54 54 54 54 54 54 54 63 63 72 72 108 108 108 108 108 108 108 126 126 126 144 144 144 144 8 30.2 54 54 54 54 54 54 54 54 63 72 72 108 108 108 108 108 108 126 126 126 144 144 144 - - - - 9 34.0 54 54 54 54 54 54 54 63 72 108 108 108 108 108 108 126 126 126 144 144 - - - - - - - 10 37.8 54 54 54 54 54 54 63 72 108 108 108 108 108 126 126 126 144 144 - - - - - - - - - 12 45.4 54 54 54 54 54 63 72 108 108 108 108 126 126 144 144 - - - - - - - - - - - - 15 56.7 54 54 54 63 72 108 108 108 126 126 144 144 - - - - - - - - - - - - - - - 20 75.6 54 54 63 108 108 108 126 144 - - - - - - - - - - - - - - - - - - - 25 94.5 54 63 108 108 126 144 - - - - - - - - - - - - - - - - - - - - - 30 113.4 54 72 108 126 144 - - - - - - - - - - - - - - - - - - - - - - 35 132.3 54 108 108 144 - - - - - - - - - - - - - - - - - - - - - - - 40 151.2 63 108 126 - - - - - - - - - - - - - - - - - - - - - - - - 45 170.1 72 108 144 - - - - - - - - - - - - - - - - - - - - - - - - 50 189.0 108 126 - - - - - - - - - - - - - - - - - - - - - - - - - ASME Certification Available Sizing for the proper flow rate is important. If the temperature rise requirements exceed a single SNA model, consider using model SNA-SKID series units to supply tepid water to multiple emergency fixtures. Please contact your Keltech Representative for additional product information. How to Size a Heater 1. Calculate Delta-T ( T). Set point temp - coldest ground water temp = T T = 2. Select kw required by using chart or formula below. Peak demand in GPM x T x.1465 = kw kw = 3. Confirm voltage and phase available on site. Voltage and Phase = 4. Confirm minimum flow. Minimum Flow = Page 6 of 7 12/18/2017

Heater Model SNA SKID2 SNA-Series - Safety Shower Heater with TepidGuard Safety Skid and 1-1/4" pre-piped assemblies mounted to SNA Series Heater Standard Heater Selections (Must select one from each category) Kilowatts 54 54 kilowatts 63 63 kilowatts 72 72 kilowatts AC Power Supply 3 Three Phase Voltage 480 480 Volts 600 600 Volts System Controller D Digital Control 108 108 kilowatts 126 126 kilowatts 144 144 kilowatts 380 380 Volts (down rated from 480V) 400 400 Volts (down rated from 480V) 415 415 Volts (down rated from 480V) Cabinet Enclosure N4 NEMA-4 Enclosure (standard) N4X NEMA-4X Enclosure - Stainless Steel N4X316 NEMA-4X Enclosure - 316 Stainless Steel Asset Tag 00 01 1 Asset Tag 02 2 Asset Tags 03 3 Asset Tags 04 4 Asset Tags 05 5 Asset Tags Heaters listed above can be down rated in 380, 400 and 415 volts. Contact your local Keltech Representative for power ratio and effective kw. Keltech Tankless Water Heater Skid Systems are noncancelable, non-refundable and non-returnable. Verify ASME Code applicability for all installations 58kw (200,000 btu) and higher. Product Options (Must select one from each category) AL3-SL EXP2CFPM ENHT30 FDS* GF HLW Safety Shower Model A * Not available with SNA-723/600D **Bronze pressure and temperature relief valve included as standard. Application Attributes (MANDATORY) Coldest ground water temperature: Minimum Flow: Maximum Flow: S19-304D2T - Heat traced combi unit. Class 1/Div 2, top supply, 120V, ABS showerhead, Halo eye/face wash, no alarm, no light, no drench hose, no anti-scald valve. Set point temperature 80 F/ 27 C: Stack Light with Distributed Control System Link Continuous Flow Explosion Proof Class1/Division2 Freeze Protection to -30 F Internal Fused Disconnect Ground Fault Package ASME Heat Exchanger with Level Sensor (63kW and Higher Only) Installation Accessories BSPP PRS** YS YSS Stainless steel thread adapter converts NPT to BSPP ASME pressure relief valve, stainless steel Y-Strainer Y-Strainer, stainless steel Delta T Calculation Set Point Temperature - Coldest Incoming Water Temperature = Minimum Delta T for Application Model Number Configuration S19361HF-SNA- 3 / D - - - - - - - kw Volts INSTL_ACCESSORY - - - Customer Signoff Page 7 of 7 12/18/2017