Next Generation Passivhaus Archives

Similar documents
Nick Grant Alan Clarke

The!first!Passivhaus!Archive!in!the!UK!

The importance of hot water system design in the Passivhaus

Benefits Offered by Passive Dehumidification Wheel Speed Control

Building a Better Passivhaus School

Achieving Dry Outside Air in an Energy-Efficient Manner

Dehumidification Systems

Heat loss via internal drainage vent pipes

Passivhaus school kitchens

Preventive conservation in libraries and archives

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Dehumidifying with Dedicated Outdoor Air

Hygrothermal evaluation of a museum storage building based on actual measurements and simulations

Victoria & Albert Museum, London Medieval & Renaissance Galleries: A Passive Approach to Humidity Control

LOW ENERGY AIR CONDITIONING OF ARCHIVES

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

PASSIVE HYGROTHERMAL CONTROL OF A MUSEUM STORAGE BUILDING. Jørgen Erik Christensen 1 and Hans Janssen 2

What Works Lessons in German American Collaboration

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Passive building in Hot and Humid Climates

Dehumidification: Energy Efficiency Comparisons

Munters Heat Exchangers

THE PSYCHROMETRIC CALCULATOR By: Stanley F. Gallos, The Bastian-Blessing Company INTRODUCTION PROPERTIES OF THE RSES CALCULATOR

Heat pump and energy recovery systems

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Museum of Bavarian History Regensburg, Germany

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Chilled Ceilings / Beams Working Principles & Applications

Chilled beam technology overview John Woollett 1, Jonas Åkesson 2 Swegon AB 1,2

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Principles of Active Desiccant Operation. Presented by Tom Peterson, CEO and Founder. Climate by Design International

Low energy museum storage

Psychrometric Engineering Applications

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Optimisation of cooling coil performance during operation stage for improved humidity control

Heat Recovery Units. Heat Recovery 1

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

Section 4 of 6 DOAS Core Technologies

Larch house and Lime house review of systems design and implementation

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Fifteen Years of Dehumidification Results from Heat Pump Water Heaters

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

seasons in regions with hot, humid climates. For this reason, a dehumidification system with a radiant panel system needs to be developed. In a former

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

CONDENSATION/HUMIDITY PROBLEMS IN BREWERIES

Indoor Swimming Pools:

Dynamic performance of a novel dew point air conditioning for the UK buildings

» WITH REGASORP ROTARY HEAT EXCHANGER

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

Dehumidification Strategies Application Note

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

product application data PERFECT HUMIDITY DEHUMIDIFICATION SYSTEM

Relative Humidity in Schools Jim Cummings and Chuck Withers

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Villa Bagatelle Technical Report

Improving the (museum) indoor climate in a flooded castle

CHAPTER 4. HVAC DELIVERY SYSTEMS

K.F. Fong *, C.K. Lee, T.T. Chow

Ten years experience of energy efficient climate control in archives and museum stores

DEMAND-CONTROLLED HOME VENTILATION

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Radiant Heating & Cooling for Commercial Buildings

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

Comfort and health-indoor air quality

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

Your guide to condensation and how to reduce it. Come home to comfort

Desiccant Cooling with Solar Energy

Modular Active. Chilled. Beams

VENTILATIVE COOLING CONTROL STRATEGIES APPLIED TO PASSIVE HOUSE IN ORDER TO AVOID INDOOR OVERHEATING

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

Chifley Passive House: Two years of performance data Harley Truong 1 and Andrew Garvie 2 November 2016

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Cold Storage Warehouse Dock Parametric Study

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

Impact of indirect evaporative air cooler type on the performance of desiccant systems

PRODUCT OVERVIEW. Dehumidifiers

To Keep Docs Cool, Dry and Happy

The Potential for Solar Powered Desiccant Cooling

Cooling the Data Center

Article Energy Saving Benefits of Adiabatic Humidification in the Air Conditioning Systems of Semiconductor Cleanrooms

Chilled Beams. Getting a Warmer Reception

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Everything you need to know about Radiant Heating but didn t dare ask

Chilled Water system

Experimental Investigation of the Padding Tower 1. for Air Dehumidifier

LATENT COOLING LEAD. Kecha Thirakomen EEC Engineering Network

Transcription:

Next Generation Passivhaus Archives Alan Clarke, Gloucestershire, UK, alan@arclarke.co.uk Nick Grant, Herefordshire, UK, nick@elementalsolutions.co.uk Andy Jarvis E3, Bath, UK, andy.jarvis@e3ce.com 1 Introduction Lessons from HARC, The first Passivhaus Archive in the UK The Hereford Archive and Record Centre (HARC) was the first Passivhaus Archive in the UK [Grant 2016]. Whilst the repository and records building are certified to the Passivhaus Standard, the repository owes more to the passive conservation storage approach of Tim Padfield and his colleagues in Denmark [Padfield 2017]. Contributions from the Passivhaus approach include excellent airtightness detailing and thermal continuity of the envelope. Two years of operation at HARC has shown that close control of the supply air condition is not necessary: monitoring demonstrates excellent temperature and RH stability with simplified operation can be achieved by simply cooling the supply air to reduce the absolute moisture level close to that required in the store. Figure 1. Temperature and RH monitoring of the middle floor of HARC since practical completion. The supply air flow rate is set very low, at less than one air change per day and is intended to slightly pressurise the building to effectively eliminate infiltration of unconditioned air. The repository air tightness via external walls is around 0.05 m/h so most overflow is via internal doors to the occupied part of the building. We have now designed a new archive for paper storage, under construction in 2018, which builds on the lessons learnt from HARC.

No heating HARC was designed to be heated to maintain a minimum temperature of 14 C. In fact the heating has not operated at all. This is partly due to higher than expected heat gains from lighting, but also we discovered that the archivists didn t need this minimum temperature to be maintained. Provided that conditions are such that condensation doesn t occur when material is removed from the archive for viewing elsewhere then lower temperatures are better for preserving paper. The client for the new archive was consulted and we are planning for a minimum temperature as low as 10 C which will avoid the need to install any heating plant. No floor insulation We debated whether to insulate under the slab at HARC but decided to do this after the PHPP model showed lower heating energy consumption with insulation. Now we can let the archive temperature drop we don t need insulation, and in fact the thermal mass of the ground will transfer heat into the archive in cold weather. In summer the heat loss to the ground is beneficial. Although HARC has stayed below the target 20 C, since chemical degradation increases with temperature, lower is better and with ground-coupling we expect to stay below 15 C. Thermal modelling shows that simple edge insulation will ensure that surface temperatures in the repository are high enough to avoid risk of mould, given the low absolute humidity we will maintain inside. So this change will improve conditions and reduce construction cost. Figure 2. Ground coupled slab with edge insulation to avoid mould risk (repository temperature 12 C).

Simple supply-air conditioning A cold water cooling system has to run several degrees above freezing so the dew point of the fresh air supply is typically 8-10 C. This is equivalent to 60% RH around 16 C, so this is too high a moisture level for a repository expected to be at 10-15 C. Following design modelling, the HARC supply air system used both cooling coils and a desiccant dehumidifier to ensure the moisture content could be reduced sufficiently. Since the desiccant dehumidifier adds heat an additional cooling coil was added for post cooling. With water in the coils, a frost heater was added to the intake. We have now designed future archive systems to use a single means of dehumidification, and developed a bespoke spreadsheet to analyse the implications of this. 2 Modelling Monthly moisture balance With a highly sealed building and very low ventilation rate the quantity of moisture absorbed into the building fabric and the archive contents becomes the main factor determining relative humidity in the building. The moisture content of the materials tends to equilibrium with the relative humidity in the air when the environment is sealed. With conventional air conditioning, the much higher air flow negates this moisture buffering effect and so relative humidity in the space is modified by adjusting the properties of the air using air conditioning plant. With our airtight passive archive we have a very small air flow so the relative humidity is largely dependent on this moisture balance with the archive materials. We developed a spreadsheet based moisture balance model with a monthly time step. This accounts for the moisture contained in the building contents and calculates the corresponding equilibrium relative humidity and air temperature. This allows an estimation of net moisture change through ventilation for the month and hence estimation of total moisture mass within the building the following month. Figure 3. Modelled repository temperatures. To provide detailed input of fabric solar gains and ground temperature to the model we used a modified version of PHPP: we added a monthly internal heat gain sheet to allow for

gains and losses from dehumidification plant, and then used the summer sheet for the monthly energy balance. Figure 4. Modelled air absolute moisture content and relative humidity. Two dehumidification options were modelled, firstly a desiccant dehumidifier, which tends to add heat to the building, and a chiller coil, which tends to cool the building. Modelling conclusions minimum temperature with no heating and no floor insulation = 11-12 C internal air moisture content required for 40%-60% RH at this temperature = 4.5 g/kg chiller dehumidification has to cool air supply to 2-4 C most dehumidification of supply air is required during summer In practice desiccant dehumidification works least well during warmer conditions with low relative humidity but high absolute humidity, and would not be able to meet the supply air moisture content required at peak times, whereas a suitable sized chiller and cooling coil will always be able to do this. The down side is that during summer the chiller would be providing a large amount of sensible cooling which is unnecessary. ( Sensible cooling reduces the temperature of the air, latent cooling reduces the moisture content of the air.) We can avoid this by using cold off-coil air to precool incoming air. We explored the use of a counter-flow air-air heat exchanger now available at high efficiency for use in passive house ventilation systems. 3 System design The diagram below shows example summer conditions. The incoming air enters the MVHR in the normal place of extract air, and the chiller is outside. The incoming is cooled and starts to condense, and arrives at the chiller at close to 100% RH and relatively cool. It is chilled further to 3 C and 100% RH, and then takes the place of incoming fresh air in the MVHR and is warmed to a temperature close to that of the original intake air, though at very low humidity.

Basically the heat recovery unit recovers the sensible heat in the process so that the duty of the chiller is restricted to latent heat only. Figure 5. Supply air dehumidification with energy recovery. Figure 6. Psychrometric diagram of process.

Figure 7. Average monthly chiller load including effect of heat recovery. 4 Conclusions Monitoring of the HARC Passivhaus archive shows that an airtight passive envelope with minimal building services inputs provides a very stable storage environment at the desired conditions. For archive storage of documents at cool temperatures (down to 10 C) our experience at HARC shows that such an archive can be built with no heating and no floor insulation in the UK climate. Such ground-coupling will add to thermal stability and minimise summer temperatures. Conditioning is still needed to control humidity to the required conditions of 40%-60% with minimal variation. To achieve this with the lowest energy cost a very airtight construction is needed so that infiltration is prevented by slight pressurisation with a low ventilation rate. The supply air requires dehumidification to meet the moisture level of the cool internal air. Using a chiller for dehumidification provides unnecessary sensible cooling as well as the latent cooling required. By using an air to air heat exchanger to cool the incoming fresh air with the chilled air reduces the load on the chiller by around 50%. References [Grant 2016] [Padfield 2017] Clarke, A.: Grant, G.: The First Passivhaus Archive in the UK. In: Feist, W. (ed.): Proceedings of the 20th International Passive House Conference 2016 in Darmstadt. Passive House Institute, Darmstadt, 2016. Padfield, T.:Ryhl-Svendsen, M.:Klenz Larsen, P.: Aasbjerg Jensen, L.: Drifting temperature air conditioning. Download: www.conservationphysics.org