UB20 12V DC. Owner s Manual

Similar documents
GX200/ GX200L. Owner s Manual

EURAMCO SAFETY S CERTIFIED PRODUCT MARK OF EXCELLENCE

owner s manual & parts list

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

PROFESSIONAL AIR MOVER OWNER S MANUAL

Dr. Infrared Heater Elite Series

Owner s Manual CMC100 Dehumidifier

Owner s Manual CMC100 Dehumidifier

INFRARED ZONE HEATING SYSTEM

EVAPORATIVE AIR COOLER SERVICE MANUAL

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Installation and Operation Manual

BIG BEAR VORTEX FAN MODEL #BB-2

Operating Instructions

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

Infrared Portable Space Heater

LOW PROFILE AIR MOVER

OWNER S MANUAL. General Ventilation Fans Electric Driven. PAL Series (Incl. 24 & 30) HD Series (Incl. -T & -S) 0316_01A

Full Size Canister Service Manual Riccar Models 1700 / 1800 Power Nozzles RPB-100 / RPB-220 / RPB-224 / RPB-250

40E ELECTRIC FAN HEATER

Decon Scrubber Owner s Manual

TSS 15/55 Hi-Lift Vacuum

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

OPERATING MANUAL 12 AXIAL FANS

Infrared Portable Space Heater

INFRARED ZONE HEATING SYSTEM

HX18 Heater. Read all instructions before using the heater. Contents

User s Manual & Operating Instructions

Zeus Extreme Owner's Manual

Panel Fan Series Operators Manual (Galvanized and Polymer)

Air Storm Fans. Air Storm 54 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

8 lb Lightweight Vacuum Model CK LW 13/1

9420* & * Coin Operated Models C* Commercial Models. Product Information. Important Safety Instructions

Canister Vacuum. OWNER S MANUAL Models CV520HB/HR/HY 120V., 60Hz., 10 Amps

40E ELECTRIC FAN HEATER

PORTABLE SMART WASHER

SSS BPV- 40 Backpack Vacuum

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

SPECIFICATIONS FEATURES

The Family Ceramic Heater

BK17 Heater. Read all instructions before using the heater. Contents

Installation and Maintenance Manual Please retain this manual for future reference.

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

14 Upright Vacuum with HEPA Filter & Dual Power

690 Power Fishing System

Electric Fireplace Insert with Heater OWNER S MANUAL Model No. FP404R-Q

Manufacturer of RAMFAN Portable Ventilators. Fire Rescue Portable Ventilation Solutions for Smoke Removal

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

LARGE AREA VACUUM LAV-30

Thanks for shopping with Improvements! Springfield Compact Electric Fireplace Item #470279

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

True Hepa Shark Plus Canister Vacuum Model EP238 Use and Care Instructions

INSTRUCTION MANUAL Model: SU3022

PERSONAL SIZE FIREPLACE

Phoenix AirMAX - Radial Air Mover

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

Infrared Portable Space Heater

Ceramic heater FAN. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

DUST EXTRACTOR MODEL No: CDE1000

WAV-30 WIDE AREA VACUUM

SAFETY PRODUCTS CATALOG

DUST COLLECTOR OPERATION AND SAFETY INSTRUCTIONS FM230 CAUTION: READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE

Owner s Guide. Powerhead Canister Vacuum Cleaner

OPERATING INSTRUCTIONS

CLASSIC PLUS INFRARED ZONE HEATER

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

#8 STAINLESS STEEL ELECTRIC MEAT GRINDER OWNER S MANUAL

SERVICE PARTS/OPERATION for

FLAME CUBE ELECTRIC FIREPLACE MODEL EF-BLT02 OPERATION MANUAL

30-pint Dehumidifier User Guide

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

MeacoClean CA-HEPA 119x5 Air Purifier

Quest Power Electric Heat EHS 31 Pro

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Dual Suction System Pro-Lite

8648 Series Air/ Water/ Vacs. Product Information. Important Safety Instructions. Operating Instructions Maintenance & Troubleshooting REV

Locally Controlled Bug Killers. Read all instructions before using the bug killer. Contents

OptiClean. U S E R S G U I D E 6 0 A 4 S E R I E S v. Product View. Assembly. Operations. Maintenance and Care.

Electric Fireplace Insert with Heater

INFRARED QUARTZ HEATER

Turbo Circulating Fan (DC)

Register at

Air Reach Upright VACUUM CLEANER

7140 Dust Collector Owner s Manual

Summer Breeze Heater Service Manual

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

INFRARED ZONE HEATING SYSTEM

Get Cleaning... What s your Vax s model number? User Guide VA X. Bagless Upright. VAU1200 / VARU1200 / VAUW1200

PORTABLE DEHUMIDIFIER

Transcription:

UB20 Owner s Manual 12V DC Euramco Safety, Inc. 2746 Via Orange Way Spring Valley, CA 91978 USA USA 1.800.4.RAMFAN Tel +1.619.670.9590 Fax +1.619.670.7345 theteam@euramcosafety.com www.euramcosafety.com SM-UB2012V Rev B

Preface Thank you for purchasing the RAMFAN UB20 12V utility blower manufactured by Euramco Safety, Inc. For more than 30 years Euramco Safety has been on the cutting edge of industrial, fire, and marine ventilation products. Each and every one of our blower/exhausters, smoke ejectors, PPV & LSV fans and accessories represent the finest technologies available. Every product is constructed to demanding and exact specifications for quality, performance, and reliability. When human life depends on having a fan that can deliver clean, safe air, you have only one choice you can trust: RAMFAN. Explore our website and online catalog at www.euramcosafety.com and discover how RAMFAN can make a difference in the field! This manual covers operation and maintenance procedures for the RAMFAN UB20 12V utility blower/exhauster. All product information in the publication is based on the most current information available at the time of printing. Euramco Safety, Inc. reserves the right to make changes at any time without notice. READ MANUAL BEFORE STARTING FAN FOR FIRST TIME! UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 1

Table of Contents 1 Specifications/Warnings... 3 2 Features & Benefits... 3 3 Safety Precautions... 4 4 Operation... 5 5 Maintenance... 5, 6 6 Troubleshooting... 6 7 Spare Parts... 7 UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 2

1 Specifications/ Warnings MODEL UB20 12V Part Number ED9002 Airflow 862 cfm / 1465 m 3 /hr Volts 12V DC Amps 11.5A Motor output max. 1/4 Hp / 0.19 kw Protection class IP55 Height x Width x Length 14 x 12 x 13 in / 36 x 31 x 33 cm Weight 17 lbs / 8 kg Sound level @ 3 / 1 m 74 db(a) @ 3 / 1 m * Specifications are subject to change without notice. Some values are approximate. CAUTION! This fan requires a 12VDC battery power source. Do NOT use a higher voltage battery than 12VDC. The UB20 12VDC blower/exhauster is also available with RAMFAN's Battery Pak and charger system for up to 10 hours of operation. 2 Features & Benefits RAMFAN combines high performance turbofan design with high strength polymers to create a line of rugged, portable turbo blowers. The UB-Line is ideal for general use, confined space ventilation and delivers the highest airflow in its class. The double-wall, polyethylene casing is light-weight, corrosion and chemical resistant and handles the bumps and falls of any job site. The 8"/20 cm UB20 turbo blower is at the heart of the RAMFAN industrial ventilation systems that provide you with the complete solution for common confined space ventilation applications. The multi-purpose blower and exhauster delivers powerful airflow in a compact and lightweight package. Compact & Lightweight Integrated Duct Adapter Cord Strap 15'/4.6 m Extended Reach Jumper Cable Ultra-Quiet Easily attaches Quick-Couple Duct Canister for Exhaust/Suction UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 3

3 Safety Precautions Before Operation Before starting for the first time: DO NOT START fan if there are any signs of shipping damage, particularly to blade, guards, or housing. If ANY damage is suspected, STOP and call your dealer immediately. Keep children away: Do not allow children to play with or around the unit, which could result in injury. Be sure the unit is inaccessible to children when not attended. Power Cable: Only use power cable or jumper cable provided by Euramco Safety for use with RAMFAN UB20 12V. Handle with care: Do not drop or throw the unit. Rough treatment can damage the components or wiring and create a hazardous condition. Run on stable surface: Start only if blower is sitting in a stable and upright position. While on level surface and running at full speed, the blower should not move around. If unit is moving, check rubber feet for damage and replace if necessary. Secure during transport: When transporting in a vehicle, secure the unit to prevent sliding and possible injury to vehicle occupants. During Operation Airflow Direction: When using the blower, note the directional airflow indicator on the external housing. Keep out of water: Never operate the unit in pooled or standing water, as this may create a risk of injury from electrical shock. Do not store outdoors. If electrical wiring or components become wet, thoroughly dry them before using the unit. Safety: Proper ear and eye protection must be worn while blower is running. Keep fingers and hands clear of blade. Do not move blower while it is running. Keep air intakes clear: Do not clog or block air intakes, this may occur if operated to close to loose lightweight objects such as clothing or leaves. This can cause the unit to overheat and result in a fire or electrical hazard. Keep away dust and dirt: Do not allow dust, dirt, or other particles to be drawn into the air intakes. Dirt in the motor can cause it to overheat, resulting in a fire or electrical hazard. If the motor gets dirty, clean it using a compressed air hose. Allow repair only by qualified person: Immediately stop the unit upon hearing excessive mechanical noise or vibration. Do not attempt to disassemble or repair the unit if you are not qualified to do so. You can perform regular maintenance or troubleshooting, however complex problems need to be repaired by an authorized service technician. For information about authorized repair, call Euramco Safety Customer Service at +1 (619) 670-9590 or email us at theteam@euramcosafety.com. UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 4

4 Operation 1. Read the Owner's Manual completely before starting fan. 2. Wear both eye and ear protection. 3. Position the fan on a level surface. 4. Make sure the switch is in the "OFF" position before connecting a power source. 5. This blower is supplied with a 15ft jumper cable that plugs into the blower and is designed to clip to a 12V vehicle battery. The UB20 12V may be powered by any 12V source with sufficient capacity (See specs in table above). Battery life will depend on the capacity of the power source. 6. Check vehicle battery, clean terminals. 7. Connect jumper cable to the fan and clamp the ends to the appropriate terminals on a 12V vehicle battery. When the unit is properly connected to the power source, flip the toggle switch to the ON position. 8. Check for proper operation before leaving the unit unattended. Do not move or carry the blower while it is running. 5 Maintenance LOCK-OUT / TAG-OUT: When performing any maintenance, always follow all additional safety precautions that your company may have for lock-out / tag-out procedures. POWER OFF: Always turn the power OFF and unplug the unit before performing maintenance procedures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed. DO NOT DISSASSEMBLE blower for maintenance reasons. INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals. Periodically, inspect internal wiring for bare wires, insecure fasteners, and discoloration. Remove and repair any damaged wiring as needed. Failure to do so may lead to electrical shock or a fire hazard. CLEAN AIR INTAKES: Clean off any accumulated lint or other materials from the finger guards. A build up will reduce the airflow and may cause the motor to overheat and become a fire hazard. NEVER operate fan with damaged or missing finger guards. CLEAN EXTERIOR: Clean fan periodically to remove accumulated dust or particles using a commercially available biodegradable cleaning solution. DO NOT use solvents containing chlorinated hydrocarbons (i.e. MEK, Acetone) EXTERIOR INSPECTION: Evaluate exterior components and make sure they are properly installed. Inspect the fan for loose fasteners at least once every 6 months depending on frequency of use. Tighten any loose fasteners immediately. DO NOT overtighten fasteners. UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 5

LISTEN to the unit for abnormal sounds. Check rubber feet for excessive wear or breakage. Contact Euramco Safety for replacement parts and installation instructions. DO NOT WET MOTOR OR WIRING: To prevent damage to electrical components, do not use a duct or pressure washer to clean a blower. If electrical components do become wet, dry them immediately. 6 Troubleshooting WARNING: Execute all the service procedures below with the blower OFF and power cord unplugged. "FS" or Field Solutions can be handled by the technician in the field "AST" or Authorized RAMFAN Service Technician PROBLEM CAUSE See Above SOLUTION Motor won't run No power to machine FS Plug in the unit; check circuit breaker or fuse Motor runs but impeller turns erratically or scrapes Switch not turned on FS Turn on the switch Blower impeller jammed FS Remove material jamming impeller Intake or exhaust blocked FS Turn machine off and allow to cool, then remove blockage Switch is broken AST Call distributor or Euramco for replacement switch Loose wiring AST Check wiring and tighten as needed Severe jolt has caused motor mount to bend and impeller to rub Unit vibrates excessively Accumulation of soil on impeller FS Clean blower impeller AST Remove motor from housing, then replace or repair bent motor mount Blower impeller has lost balance AST Balance or replace blower impeller Blower impeller has been bent AST Replace blower impeller Bent motor shaft AST Replace motor UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 6

7 Spare Parts Contact factory for replacement parts and installation instructions. Model UB20 12VDC Corresponding Bubble No. RAMFAN P/N Description 1 BL011 Impeller 2 ST010 Stator 4 ED4001 Intake Grill 8 EZP80783007 Retaining Clip 10 FZ-9540K46 Rubber Foot w/washer (4) 11 ED4003 Exhaust Grill 26 ED0109DC2 UB20 DC Switch Plate Assembly w/smh Connector To order spare parts call Euramco Safety +1.619.670.9590 or email theteam@euramcosafety.com UB20 12V Owner s Manual Euramco Safety, Inc. SM-UB2012V Rev B 7