USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

Similar documents
USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY VENTILATOR

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

USER'S MANUAL. Micra 150 HEAT RECOVERY UNIT

IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

HEAT RECOVERY AIR HANDLING UNIT

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

USER S MANUAL. VKP Series INLINE FAN

USER MANUAL. Air handling unit with heat recovery. VUT 300 EVK mini EC VUT 300 EV mini EC VUT 301 EVK mini EC VUT 301 EV mini EC

HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

Installation manual Mini Comfort 50 S/L 07/ V EN

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

VUT 350 H VUT 500 H VUT 530 H VUT 600 H VUT 1000 H VUT 2000 H HEAT RECOVERY AIR HANDLING UNIT

USER S OPERATION MANUAL HL-RD 2000 E EC HL-RD 3000 E ЕС

SOUND-INSULATED FAN. Iso-B OPERATION MANUAL

CENTRIFUGAL FANS user's manual. model VENTS VK.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

USER S MANUAL VUT 160 P2B EC A14 VUT 160 PB EC A14 VUT 350 P2B EC A14 VUT 350 PB EC A14 HEAT RECOVERY AIR HANDLING UNIT

РУКОВОДСТВО USER ПО MANUAL ЭКСПЛУАТАЦИИ CENTRIFUGAL INLINE FANS VKM / VKMZ / VC SERIES

USER'S MANUAL. Single-room reversible energy regeneration ventilator. TwinFresh R-50 TwinFresh RA-50 TwinFresh R-50-2 TwinFresh RA-50-2

SINGLE-ROOM REVERSIBLE UNIT WITH HEAT AND HUMIDITY RECOVERY VENTO V50-1 OPERATION MANUAL

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

INTELLIGENT AXIAL FAN user's manual

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

AXIAL FANS USER S MANUAL

INLINE MIXED FLOW FANS IN SOUND INSULATED CASING VENTS TT SILENT M USER MANUAL

Centrifugal inline fans

AIR HANDLING UNIT WITH HEAT RECOVERY

SINGLE ROOM HEAT RECOVERY AIR HANDLING UNIT

DUCT COOLERS KWK KFK OPERATION MANUAL. KWK_KFK_v2(4)_EN.indd :35:29

OPERATION MANUAL CENTRIFUGAL INLINE FAN WITH ELECTRONICALLY COMMUTATED MOTOR VKM EC SERIES. F88EN-02.indd :07:11

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

CENTRIFUGAL CEILING EXTRACT FAN

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

CENTRIFUGAL CEILING EXTRACT FAN

Quest 105, Dry155, and 205 Dual

Quest Dry 105, 155, and 205 Dual

Air handling unit. BlauAir RH USER S MANUAL

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

USER S MANUAL VUT V(B) EC А14 VUE V(B) EC А14. Heat/heat and humidity recovery air handling unit

READ AND SAVE THESE INSTRUCTIONS

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

HEAT RECOVERY AIR HANDLING UNITS

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

HEAT RECOVERY AIR HANDLING UNITS KOMFORT EC S S11/S15 KOMFORT EC SB S11/S15

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

breeze easytm model # F100-1W

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

READ AND SAVE THESE INSTRUCTIONS

5) Do not start or stop the unit by inserting or pulling out the power plug.

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Turbo. Service Instructions

To make planning your kitchen even easier, IKEA has developed a complete line of high quality major appliances that are designed for everyday use and

USER'S MANUAL PS

Outdoor Refrigerator USER S MANUAL

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Series VENTS VUT R WH ЕС

MH70230AS MH70236AS MH70248AS

Quest Dry. Quest 110 Dual. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

WHYNTER PORTABLE ICE MAKER 49 LB CAPACITY - STAINLESS STEEL

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

DEHUMIDIFIER. User Manual 50BT, 70BT

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

XC Portable Air Conditioning

ELECTRIC FIREPLACE OWNER S MANUAL

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

Ui REFRIGERATOR SPEC SHEET

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Outdoor/Commercial Refrigerator USER S MANUAL

HANDY/STICK 2-WAY VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H055

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Portable Air Conditioner

INLINE MIXED-FLOW FANS VENTS TT SERIES USER'S MANUAL.

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

12,000 BTU Evaporative Portable Air Conditioner

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

Appliances SAVE THE SALES RECEIPT! It is your proof of purchase and required for the limited warranty to apply.

Portable Dehumidifier with Internal Pump

Whynter Portable Ice Maker 33 lb capacity - White

PORTABLE AIR CONDITIONER OWNER S MANUAL

READ AND SAVE THESE INSTRUCTIONS

VENTILATION FAN WITH LED LIGHT AND HEATER MODEL RAD110LED

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

PORTABLE AIR CONDITIONER OWNER S MANUAL

Owner s Guide. 24-inch Gas Wall Oven with Time-Of-Day Clock and Timer Canada w A/01/08

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

USER S MANUAL DN-2. Drain pump

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

User s Information Manual

AirInstinct Air Purifier

DanVex AD-550 Adsorption air dehumidifier. Operation manual

Operating Instructions

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

Transcription:

USER S MANUAL Heat Recovery Ventilator Vents Brig HRV 200 Vents Brig HRV 300

2 Brig HRV 200 (300) CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key... 4 Basic unit dimensions... 4 Technical data... 5 Safety requirements... 5 Structure and operating logic... 6 Mounting and setting-up... 7 Condensate drainage... 8 Unit connection to power mains... 9 Unit control... 10 Servicing and maintenance... 12 Troubleshooting... 13 Storage and transportation rules... 14 Manufacturer s warranty... 14

3 INTRODUCTION This user s manual combines technical description, operation and service manual, technical data sheet and installation guidelines for the heat recovery ventilator Brig HRV 200 (300), hereinafter referred to as the unit. APPLICATION The unit is designed to save thermal energy by means of heat recovery and is one of the energy saving components used in the buildings and premises. The heat recovery ventilator is a component unit and is not designed for independent operation. The unit is designed to provide permanent controlled air exchange by mechanical ventilation in houses, offices, hotels, cafés, conference halls and other residential and public premises as well as utilization of extract air heat energy to warm up supply purified air. The unit is for ceiling mounting. The unit is rated for continuous operation always connected to power mains. Transporting medium must not contain any flammable or explosive mixtures, evaporation of chemicals, coarse dust, soot and oil particles, sticky substances, fibrous materials, pathogens or any other harmful substances. The unit is not designed to be used by children, physically or mentally disabled persons, persons with sensory disorder, persons with no appropriate experience or expertise. The unit can be operated by qualified experts after appropriate instruction about its use and operation. The unit shall be mounted in places inaccessible for children. DELIVERY SET Unit Brig HRV 200 (300) User s manual - 1 pce; Drain hose Oil filter Packing box - 1 pce; - 1 pce; - 1 pce; - 1 pce; - 1 pce.

4 Brig HRV 200 (300) UNIT DESIGNATION KEY Brig HRV 200(300) Air capacity [CFM] Unit type: HRV - Heat Recovery Ventilator BASIC DIMENSIONS A B E C G IØ D F H Table 1 Fig. 1 Overall and connection dimensions Unit type Ø D A B C E F G H I Brig HRV 200 6" 32 3/8 28 7/16 17 5/16 8 5/8" 11 3/4 6" 23 11/16 24 5/8 Brig HRV 300 8" 40 5/8 36 3/4 17 5/16 8 5/8 12 3/4 6 7/16 25 11/16 26 9/16

5 TECHNICAL DATA The unit is designed for indoor application with the ambient temperature ranging from +34 F (1 С) up to +122 F (50 С). Ingress Protection rating: IP44 for the unit motors; IP 22 for the assembled unit connected to air ducts. The Vents Brig HRV 200 unit net weight is 68 lbs (31 kg); the Vents Brig HRV 300 unit net weight is 93 lbs (42 kg). The unit series designation, basic overall and connecting dimensions are shown in fig. 1 and in tables 1. The unit design is regularly being improved, so some models can slightly differ from those ones described in this manual. SAFETY REQUIREMENTS While operating and mounting unit fulfill the requirements of the present operation manual as well as general requirements of all applicable codes and standards valid in USA and Canada. Ground the unit! Before connecting the unit to power mains make sure that the unit is free of any visible damages or any other foreign objects inside the casing that can damage the impeller blades. Connection of the unit to power mains by duly qualified and authorized electricians only! Warning! Mounting, servicing, connection and repair works of the unit are allowed after the unit is disconnected from power mains. Do not! Do not operate the unit beyond the specified temperature range or in an aggressive and explosive medium. Do not connect clothes dryers or similar equipment to the ventilation system. Do not operate the unit in the air and dust mixture environment.

6 Brig HRV 200 (300) STRUCTURE AND OPERATING LOGIC The unit has the following operating logic (fig. 2): Warm stale extract air from the room flows through the air ducts to the unit, is purified in the extract filter and is supplied to the heat recovery core and exhausted outside by exhaust fan. Clean cold air from outside is moved by supply fans to the unit where it is purified through the supply filter. Then clean air flows through the heat recovery core and is supplied to the room by supply fan. Thermal energy of warm extract air is transferred to clean intake fresh air and warms it up. The extract and intake air flows are fully separated during heat recovery which excludes any transfer of odors and pathogens to supply air. Heat recovery minimizes thermal energy losses, energy demand and heating costs. BRIG HRV 200 5 2 SUPPLY AIR EXTRACT AIR EXHAUST AIR INTAKE AIR BRIG HRV 300 8 6 7 3 1 4 4 5 INTAKE AIR EXTRACT AIR EXHAUST AIR SUPPLY AIR 2 8 7 6 3 Fig. 2. Unit structure and operating logic 1

7 1. Supply fan with backward curved blades and maintenance-free motor with external rotor and integrated thermal protection. 2. Extract fan with backward curved blades and maintenance-free motor with external rotor and integrated thermal protection. 3. Plate cross flow heat recovery core that can be replaced with a summer block when no need for heat recovery. 4. G4 supply air filter. 5. G4 extract air filter. 6. Drain pan. 7. Drain hose (included into delivery set). 8. Frost protection thermostat. MOUNTING AND SETTING-UP While mounting the unit provide enough access for the unit maintenance and servicing. Mount the unit to ceiling with threaded rods fixed inside the dowels attached to the ceiling or by means of the belts that are rigidly fixed to horizontal plane. The unit can be installed on mounting supports with adjustable height for connection to the drain system (fig. 3). min 20 min 4 Fig. 3. Unit mounting

8 Brig HRV 200 (300) To attain the best performance of the unit while mounting provide a straight 20 (500 mm) duct section in front and behind the unit. The unit must be equipped with a grille with the mesh width up to 1/2 or any other protecting device to prevent free access to the unit fans. CONDENSATE DRAINAGE The unit is equipped with a condensate drain hose for condensate drainage (fig. 4). Connect the drain hose (1), U-trap (3) and drain system (5) with metal, plastic or rubber pipes (2 and 4). The pipes must be sloped down at least by 3. Before starting operation of the unit fill the system with water and check that U-trap is always filled with water. Make sure that the water drainage is correct, otherwise some condensate may be accumulated inside the unit and provoke subsequent equipment damage and water ingress to the room. The condensate drainage system is designed for operation at the ambient temperature above 32 ºF(0 С). If the ambient temperature is below 32 ºF(0 С), insulate the drain system and provide air heating. 1 min 3 4 5 2 3 fig. 4. Condensate drainage

L N 9 CONNECTION TO POWER MAINS Cut power supply off before any operations with the unit. The unit shall be connected to power mains by a duly qualified electrician only. Rated values of the electrical parameters are shown on the rating plate. Any modifications of the internal connections are not allowed and will void the warranty. The unit is designed for connection to single-phase ac 120 V / 60 Hz power mains. The unit is equipped with a power cable and a plug and can be connected to any standard grounded outlet. The power cable is connected to the terminal X1 by default. Connect the unit to power mains through the external automatic switch integrated into the fixed wiring system that breaks the circuit in case of short circuit or overload. Install the circuit breaker to have a free quick access in case of need to turn the unit off promptly. The unit has overload protection provided by the thermal fuse which is activated in case of overload or short circuit. To replace the thermal fuse, disconnect the unit from power mains, remove the overload or short circuit. Remove the thermal fuse and check the unit. Wiring diagram is shown in fig. 6. The thermostat TS1 (fig. 6) provides freezing protection of the unit during cold season. As the thermostat is activated, the supply fan stops and the heat recovery core is warmed up with extract air stream. To adjust the thermostatic switch, rotate the control dial to required setpoint. The setpoint depends on the operating conditions. Recommended setting of the thermostat is 37 F (+3ºС), set in the factory by default. SW2 Low Stand by Med ~120V ~24V TR1 Х4 9 2 10 White White Red Red 2 11 Low Med G0 High ~24V PE Х6.1 Х3 1 2 3 4 5 6 SetupofLow Х6.2 SetupofMed Х5.1 К1 К2 К3 Х5.2 Х1 Х2 РЕ 1 Kon 1 2 Kon 2 3 PE M1 4 PE M2 5 Brown M1 6 Cap1 7 Cap1 8 Black M1 9 Black M2 10 Cap2 11 Cap2 12 Brown M2 13 Blue M1 14 Term 15 Term 16 Blue M2 3 4 Y/G Y/G 1 2 3 5 16 17 6 12 18 19 8 7 14 15 13 C 2 Black Green White t 0 SW1 Сap1 Сap2 TS1 W1 120V 60Hz М1 FAN MOTOR М2 FAN MOTOR Twowire control 2 11 termostat 1 9 10 Fig. 5. Unit wiring diagram

10 Brig HRV 200 (300) UNIT CONTROL The unit is controlled by a three-position speed switch that enables low-speed modes «Low» as well as «Med» and «Stand by» mode which enables total air quality control (fig. 6). Up to five external control devices may be connected to the terminals 2-11 (fig. 7) that turn the unit to high-speed ventilation in case of activation of any of the control devices. Three-speed switch Terminals for connection of the remote control panel Fig. 6. Unit control Switch the three-position speed controller to «Standby» mode for correct operation from the remote control panel.

11 1. Remote control (Thermostat). Set the three-position switch into the Stand by position to activate the remote control. Remote control (thermostat) functions: Unit turning on/off Setting air flow Displaying indoor air temperature 2. CO2 sensor. Recommended for use in office buildings and public premises. When carbon dioxide concentration exceeds the set point, the unit changes into the High Speed Mode. 3. Humidistat. The humidistat is used for indoor humidity control. When indoor humidity level rises above the set point, the unit changes into the High Speed Mode and runs with the high speed until the humidity level falls down below the set point. The humidity set point is adjustable. 4. Remote mechanical timer. In case of the timer activation the unit changes into the High Speed Mode. 5. Switch. In case of the switch contact closing the unit changes into High Speed Mode and reverts to permanent Low Speed Mode when the switch contacts are opened.

12 Brig HRV 200 (300) SERVICING AND MAINTENANCE Servicing of the unit is required 3-4 times per year. Besides general cleaning, the following operations are required: 1. Filter maintenance (3-4 times per year) Dirty filters increase air resistance in the system and reduce supply air flow to the premises. Clean or replace the filters as often as required, but at least 3-4 times per year. Clean the filter with running water or a vacuum cleaner. After two cleaning replace the filter. Contact your local supplier for new filters. 2. Heat recovery core maintenance (once per year). Some dust can get accumulated on the heat recovery core block even if you clean or replace the filters regularly in compliance with above procedure. To maintain the high heat exchange efficiency, pull out and clean the heat recovery core with warm detergent solution. Re-install the dry heat recovery to the unit. 3. Fan maintenance (once per year). Even if you perform regular maintenance of the filters and the heat recovery core, some dust and grease can get accumulated inside the fans and reduce the fan performance and supply air flow. Clean the fans with a soft brush or dry cloth. No water and abrasive detergent, sharp objects or solvents are allowed for cleaning to prevent the impeller damage. 4. Condensate drainage system maintenance (once per year). The drain hose can get clogged with the extracted particles. Clean the drain hose is required. Check proper functioning of the drain system by pouring some water into the drain pan at the unit bottom. Clean the U-trap and the drain tubes if required. 5. Supply air flow inspection (twice per year). Leaves and other objects can clog the intake grille and decrease the unit performance and supply air flow. Check the intake grille twice per year and clean it if required. 6. Air ductwork maintenance (once in 5 years). Even if you fulfill all the above maintenance guidelines regularly, a certain amount of dust is accumulated inside air ducts. That reduces the ventilation system performance. Clean or replace the air ducts periodically.

13 TROUBLESHOOTING Possible malfunctions and fault handling Problem Possible reasons Solving The fan(s) do(es) not start running. Cold supply air. Low air capacity. Noise, vibration. Water leakage. Power supply is off. Thermal fuse is melted. The extract filter is clogged. The heat recovery core is frozen. Too low set rotation speed. The filters, fans or heat recovery core are clogged. The ventilation system is clogged or damaged. The impeller(s) is (are) clogged. Fan screw tightening is loose. The drain system is clogged, damaged or wrong arranged. Make sure the power supply line is connected correct, otherwise troubleshoot the connection error. Disconnect the unit from power mains. Remove the overload. Replace the thermal fuse and check the unit. Clean or replace the extract filter. Check the heat recovery core condition. Shutdown the unit and turn it on after the freezing danger is no longer imminent. Check the thermostat setpoints. Check the speed control settings. Clean or replace the extract filters; clean the fans and the heat recovery core. Check the diffusers and louvre gravity shutters opening, check the exhaust hood and intake grille and clean those if required; make sure that the air ducts are not clogged or damaged. Clean the fan impeller(s). Check and tighten the screws if required. Clean the drain pipe is required. Check the drain pipe slope, U-trap and temperature conditions.

14 Brig HRV 200 (300) STORAGE AND TRANSPORTATION RULES Store the unit in the manufacturer s original packing box in a ventilation premise with the temperature range from +14 F (-10 С) up to +104 F (+40 С) and relative humidity less than 60% (at +68 F (+20 С)). Vapors or particles which can cause corrosion or damage the insulation or connection tightness are not allowed in the stock. Use hoist equipment for loading and storage operations to prevent the unit falling or excessive oscillation. Transportation with any vehicle type is allowed provided that the goods are protected against mechanical and weather damage. MANUFACTURER S WARRANTY Production meets standard operating requirements in the USA and Canada. VENTS US warrants to the original purchaser of the unit that it will be free from defects in materials or workmanship for a period of 60 months from the date of original purchase. The VENTS US warrants to the original purchaser of the unit that the integrated control unit will be free from defects in materials and workmanship for a period of 24 months from the date of original purchase. VENTS US warrants to the original purchaser of the unit that it will be free from defects in materials or workmanship for a period of 60 months from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During the stated warranty period, VENTS US will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover (a) normal maintenance and normal service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by VENTS US), faulty installation or negligence, accident, improper maintenance or repair (other than by VENTS US), faulty installation or installation contrary to recommended installation instructions. Labor to remove and replace products is not covered. The duration of any implied warranty is limited to the time period specified for the express warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. VENTS US OBLIGATION TO REPAIR OR REPLACE, AT VENTS US OPTION, SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENTS US SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty supersedes all prior warranties. If proof of sales date is absent, warranty period is calculated from the production date. The unit can be exchanged at the following address: Bodor Vents, LLC DBA: Vents-US 11013 Kenwood Road Cincinnati, Ohio 45242 Phone: (513)348-3853 e-mail: sales@ventsus.com Please follow guidelines in this manual for product problem-free operation.

15

V103EN-03(USA_120)_HVR-200-300