MiniMax Cooling Counter

Similar documents
Operating Manual. VIENNA Hot Display

OPERATING INSTRUCTIONS: Under Counter

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Premium Electric Stove

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

OPERATING INSTRUCTIONS:!

Stainless Steel Counter Refrigerators Instruction manual

Refrigerator KE T

FROST FREE REFRIGERATOR INSTRUCTION MANUAL

Cabinet Refrigerators/Freezers Instruction manual

PCR-300 PCR-300 RC. Installation and Operating Instructions

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

PICEM75 Ice Maker & Dispenser

Wine Cabinet Manual. We know you don t want to read through this manual, but trust us, there is good information in here.

User manual: Stainless steel CGN range Storage Refrigerators and FGN Storage Freezers

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

Wine Cooler. Model No. MCWC16MCG MCWC30MCG. CAUTION: Read and follow all safety rules and operating instructions before first use of this product.

LEC L6014W/S User Manual

Optimax Refrigerated Retail Merchandisers

WHD-125FW1 //WHD-125FB1/WHD-125FSS1

Wine Cooler CVD121V/CVD131V/CVD130/CVD120

USER MANUAL AND TECHNICAL MANUAL

COMMERCIAL REFRIGERATOR & FREEZER SERVICE MANUAL (SCL/SCLM)

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 17 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 19

V 120 SG - V 160 SG. Instructions for use

CREMALDI Cream machines Operating instructions

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

Gebrauchsanleitung Weinklimaschrank Seite 2. Operating Instructions Wine storage refrigerator Page 14. Gebruiksaanwijzing Wijnbewaarkast Pagina 26

Optimax Refrigerated Retail Merchandisers

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

FELIX STORCH, INC. SUMMIT APPLIANCE DIVISION

Freestanding Wine Cooler Instruction Manual

FR-031DDRVBE1 FR-031DDRVWE

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance...

Argos Value Tabletop Fridge

Operating instructions Wine storage cabinet Page 16

User Manual. Commercial Refrigerator And Freezer User s Manual

Operating instructions Page 16. Refrigerator Read the operating instructions before switching on for the first time

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

INDEX. Granita Machine. Operation a nd Instruction Manual

Kitchen Appliance Lift INSTRUCTION MANUAL

L / -014L / -015L

Refrigerator Freezer HD-368RWEW

SUSHI SHOWCASE BMCSS05

Mobile Air Conditioner Instruction Manual Model TC-N9KM

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

Cott Vending Inc. THESE GUIDES ARE FOR MACHINE MODEL: ROYAL 448 AND OTHER NON-ELECTRONIC (NE) ROYAL VENDORS ONLY. Store Level Vending Responsibilities

OPERATING MANUAL for CORAL WALL MOUNTED CABINETS

TCW 2000 Ice liner refrigerator and freezer PIJ

TTV 4500 / TTV 4500 HP / TTV 7000

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

HOW TO OPERATE THE FREEZER COMPARTMENT PAGE 15 HOW TO DEFROST THE FREEZER COMPARTMENT PAGE 17

PRODUCT DESCRIPTION CONTROLS

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

7 Fin Oil Filled Radiator

USER-MANUAL Tamson Cool Cube Immersion Cooler

REFRIGERAT A OR USE DF1-15 F ridge

HOW TO OPERATE THE REFRIGERATOR COMPARTMENT

BEFORE USING THE APPLIANCE

# FREEZER ZF130 BK series #

TTK 75 E OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75E-TC-002-EN

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Toaster. Model: ST17020/ST17010 (all colours) v1.0. Helpline:

Trouble Shooting Guide PWA, 3-phase (D10571)

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

USER S MANUAL. Bottom-Load Water Cooler MODEL NO. CLBL420

Silver Undercounter Larder Fridge

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Refrigerator. Thank you for your trust and for buying this appliance. We hope it will successfully serve the purpose for many years.

DECLARATION OF CONFORMITY

BEVERAGE COOLER. 3.2 Cubic Feet. Before using your Beverage Cooler, please read this manual.

HOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.

Instruction / Installation Manual. Fridge Freezer LFC60W13

INSTALLATION and OPERATION INSTRUCTIONS

Operating instructions Page 6

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

PC71 American Style Fridge Freezer

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

Whole Room Dryer WRD, WRD/110

5L Water Urn with Gluvine Function SWU5LS. Help line. v1.0

HOW TO USE THE FREEZER COMPARTMENT PAGE 16

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

SERVICE MANUAL REFRIGERATION

Table of Contents Welcome and Thank You Note:

UPUTSTVO ZA RAD USER INSTRUCTIONS GEBRAUCHSANWEISUNG ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ И СОДЕРЖАНИЮ

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Outdoor Beverage Center

USING THE REFRIGERATOR COMPARTMENT

Glue Gun 25W TTB580HTL. Barcode: WARNING: Read the instructions before using the product!

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Important Notes: Please read carefully before installing your refrigerator.

TOQUE BLANCHE GRANDE CARTE

CS and FS refrigeration units with electronic control Typ SE

KF Fridge / Freezer User Guide

TTK 70 S OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK70S-TC-001-EN

CZ51202 Larder fridge

User s Manual UPRIGHT FREEZER WHS-507FWEW1 / WHS-507FWESS1 WHS-625FWEW1 / WHS-625FWESS1 WHS-772FWEW1 / WHS-772FWESS1

Operating Instructions

Mastro GmbH Hüserstraße Hamm / Germany +49 (0)2381/ (0)2381/

Transcription:

Operating instruction HOLLAND G MBH MiniMax Cooling Counter Depth: 560 incl. door Models: MM2V2 / MM2V22 / MM22V22 / MM22STF / MM222STF / MM2222STF Please read the operating instruction carefully before using. EN

EN MiniMax Cooling Counter K. & M. Holland GmbH Congratulations! You made a good choice. Thank you for buying this perfect MiniMax Cooling Counter. This cooling unit was made on the most modern production way. The full-foamed housing guarrantees a low energie consumption. This operating instruction shall give you some details for the perfect use of your cooling counter. If you have further questions, please contact your cooling specialist. Table of contents 1. Mounting instruction (general)... 3 2. Installation... 3 Integral Models Remote Models 3. Energie saving / environmental protectio... 4 4. Digital controller... 4 Setting the temperature Keypad lock ON and OFF 5. Defrost... 5 6. How to change the bulbs... 5 7. Cleaning... 6 8. Maintainance contract... 6 9. Important facts... 6 10. Trouble shooting... 7 11. Electrical sketch... 9 12. EG-Declaration of Conformity... 11 2

K. & M. Holland GmbH MiniMax Cooling Counter EN 1. Mounting instruction general Place your counter on their right place by water level! ATTENTION! After adjusting the counter feets, please press, the foamed plug and the plastic plug into the holes! This enshures a better insulation. ATTENTION, CAN TILT! Please avoid rolling or sliding the bar with doors open. 2. Installation Integral Models If your cooling counter ist mounted ready to plug in, please put the plug into the socket. The current has to be the same as on the Type button. Before using, please clean the inside of the housing. The digital controller shows the actual temperature of the housing, the ventilator works permanent. The cooling machine works immediately and cooles down, until the temperature of +4 C is reached. Remote Models (without cooler) If the condenser ist preinstalled, we recommend the following aspects! At installation, please use a pump down system for 3 (max. 4) cabinets per compressor. The prefered cooling capacity must be 150 Watts for the 1st cabinet, 100 Watts for each following cabinet. For bigger combinations please use further separate compressors or a combined bigger system in realtion with the energy consumption or safety-aspects. 3

EN MiniMax Cooling Counter K. & M. Holland GmbH 3. Energie saving environmental protection Open the doors only as long as nessessary. Please check regular the seals of the doors. A wasted condenser causes a higher energy consumption. Please clean them regular as described under point Cleaning of the condenser. Please avoid high outside temperatures, direct sun-burning or placement by a radiator, wich causes a higher energie consumption. 4. Digital controller LAE AT 1-5 Setting the temperature 1 Press button for at least half second, to display the setpoint value. 2 Use or for changing the temperature. 3 Release all buttons and wait 10 sec. Keypad lock 1 Use and immediately release button ð I will be displayed. 2 Press once ð LOC will be displayed. 3 please keeping pressed. Activating / Deactivating: Push the buttons or ð YES / NO 4 Release all buttons and wait 10 sec. ON and OFF 1 Press button for at least 3 seconds ð ON will be displayed. 2 For switch off, press button for at least 3 seconds. 4

K. & M. Holland GmbH MiniMax Cooling Counter EN 5. Defrost The defrosting works automatically all three ours. The cooling device stands still for 12 minutes. The display of the digital contoller changes to DEF (defrost). The display changes to temperature scetch, if the recommended temperature is reached or if 10 miuntes are gone. During the defrosting is a minimal rise of the temperature inside the housing possible. The core temperature of the cooling goods will not be affected. 6. How to replace the bulbs First of all and very important: Please unplug the cable. 1 Then srew of the cover sheets right and left from the illumination with a Phillips screwdriver. 2 Then move the complete casing to the left and remove it out of the counter. 3 Remove the transparent cover by pressing it lightly together. 4 Then change the bulb by turning it to the left. 1 2 3 4 Now you can foreward to replace all parts into position. 5

EN MiniMax Cooling Counter K. & M. Holland GmbH 7. Cleaning Please clean the cooling device minimum 1 time per month. 1 Open the machine housing with the included tooling. 2 Pull the plug out ouf the socket. 3 Clean the condenser with a broom or a vacuum cleaner. 4 Clean the machine case with a moist duster. 5 Put the stick into the socket and close the machine housing. 6 If nessessary please clean the fronts and grips with clean water. For the cleaning of the inside of the housing dont take aggressive cleaners, only neutral, desinfective cleaners. Dry up the inside of the housing, to avoid an higher energy consumption as a result of frosting of the condenser. 8. Maintainance contract We recommend a maintainance contract with your cooling specialist. If you need any spare parts, please contact also your cooling specialist. 9. Important facts Mounting and connection of a dispensing system has to be made only by an expert, who will inform you about all facts on operating a dispensing system. We recommend for the installation of the water connections to contact a sanitairy specialist. Pay attention on the right placement of the counter. The ventilation of the housing must be served! Noise of the cooling machine are unavoidable. By a longer time of none using the counter, please pull the plug and open the doors for avoiding a stink. If you want an other arrangement of your counter, please contact your cooling specialist. Pay attention, that the following load-carring capacities have not be broken: Drawer modul (if installed) max.: 45 kg Shelf for bottles inside the door modul: max. 75 kg each. 6

K. & M. Holland GmbH MiniMax Cooling Counter EN 10. Trouble shooting At eventually delay, please check first by using the follwing list, if you have all, in these operating instruction noted facts payed attention. If it s not possible to repair the delay, please contact your authorised cooling specialist. Fault Possible cause Find a remedy Rattling noise Display is not running Mainswitch is not glowing Loose screw connections or worn bearings No voltage Mainswitch may be OFF Contact your distributor Put the plug into the socket, controll the fuse Check the contacts on the controller (el. know-how is recommended) Display shows DEF Defrost mode Wait until defrost is finished (max. 15 min), in case of demand, please ask your authorised technician to change the spacings The controller may be wrong adjusted The evaporator is not ventilated sufficiently Door gaskets are leaking Modify the set point of the controller Control and cleaning of the evaporator (pull the plug outt of the socket) Change the door gaskets Temperature inside the cabinet is to high Evaporator fan is damaged Change the fan (el. know-how is recommended) The cooling device is damaged Repair by an authorised technician Doors or drawers are opened to long The icing of the evaporator is to much Only open the doors as long as really nessessary Correction of spacings and time of the defrost mode (el. know-how is recommended) Remove the wet or not enough covered reefer 7

EN MiniMax Cooling Counter K. & M. Holland GmbH Temperature inside the cabinet is to low Display shows E1 The controller may be wrong adjusted Fault on the thermometer probe Modify the set point of the controller Check the contacts on the back of the controller (el. know-how is recommended). Change the probe (el. know-how is recommended). Please close the doors until your cooling specialist check the delay. Dont put new cooling goods into the counter. Dont try to repair the defect by yourself, if it s not possible by the list on the left side. Otherwise the defect will become bigger than before and it may be dangerous if there ist a defect on the electrical parts. 8

K. & M. Holland GmbH MiniMax Cooling Counter EN 11. Electrical sketch 9

EN MiniMax Cooling Counter K. & M. Holland GmbH 10

K. & M. Holland GmbH MiniMax Cooling Counter EN 12. EG-Declaration of Conformity (Directives 2004/108/EC + 2006/95/EC + 2006/42/EC) Herewith we declare that this machine corresponds to the basic EEC directives for security and health demands on the basis of its conception and model, as well as of the type that we brought in circulation. This declaration loses its validity in case of modification of the machinery to which we did not agree. Relevant EC Directives: EC Machinery Directive EC Low Voltage Directive EC Directive for Electromagnetic Compatibility Applied harmonized standards: Applied national standards and technical specifications: EN 55014-1:2006+A1:2008 EN 55014-2:1997+A1:2001+A2:2008 EN 62233:2008 EN 61000-3-2:2006 EN 61000-3-3:1995+A1:2001+A2:2005 EN 60335-1:2002+A1:2004+A11:2004 Pressure Equipment Directive 97/23/EC 29.04.1997, VDE 0100, DIN 8975, UVV, VGB 20 Manufacturer: Klaus Holland Managing director K. & M. Holland GmbH Industriestr. 14 94327 Bogen Tel.: 09422 / 507-0 Fax: 09422 / 507-300 11

Cocktail Counters Juice Dispensers Mobile Bars Keg Coolers Big Volume Refrigerators Your distributor: