GAS EXTINGUISHING SYSTEM INERT GAS. Argotec with carbon dioxide. Safe for certain.

Similar documents
Carbon Dioxide Extinguishing Systems Fighting fire with CO2

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Oxeo extinguishing systems

GAS EXTINGUISHING SYSTEMS INERT GAS. Argon Extinguishing Systems. Fire Protection Systems

Technologies Gas extinguishing systems. MX 200 Fire Extinguishing Systems Fighting Fire using HFC-227ea

CO 2 EXTINGUISHING SYSTEMS

Branch Solution Wood based panel plants. Fire protection solutions for wood based panel plants

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

Fire Protection for Catering Kitchens KS 2000 Compact Extinguishing System. Safe for certain.

...extinguish it with a water spray.

CO2 COCO GAS FLOODING SYSTEM

Water mist fire suppression systems. Minifog ProCon Low-pressure water mist system

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

FIRE SUPPRESSION SYSTEM

Carbon Dioxide Fire Suppression Systems

KD Innovative extinguishing with Novec TM 1230 by 3M TM

What extinguishes fires without pressure peaks?

CO 2. fire extinguishing systems

SPRINKLER SYSTEMS UNDERCOVER-SPRINKLERS. Undercover-Sprinklers recessed and concealed sprinklers

Technologies Fire Prevention Systems. Oxeo Prevent Oxygen Reduction System Active Fire Prevention using natural Nitrogen

Fire protection solutions for ships and offshore facilities

Safe, Effective, Environment-friendly

How can you minimize consequential damages in case of a fire?

Water mist fire suppression systems. Minifog EconAqua Water mist sprinkler systems

FOREFRONT AT THE OF PROTECTION

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

ODS & SGG Alternatives for the Fire Protection Industry 2018

XC10 combined fire detection and extinguishing control

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

Inert Gas Fire Extinguishing System

SAFETY THE BEST FOR YOUR EQUIPMENT

Fire fighting Questions

EXTINGUISHES FIRES QUICKLY AND EFFECTIVELY. FirExting Gas extinguishing systems with non-liquefied and natural inert gases. Nitrogen Argon IG-541

Fire suppression systems for server rooms and data centres

An Overview of Extinguishing Systems for Computer Equipment

Welcome to Argonite fire protection from Ginge-Kerr

AUTOMATIC FIRE SUPPRESSION SYSTEMS

Vaults 5/03/2015. Introduction. Vault Types. Stand alone building Free standing structure VAULTS

AUTOMATIC FIREFIGHTING SYSTEMS IN HOSPITALS

XC10 combined fire detection and extinguishing control

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

Protezione antincendio di dati e business critical assets nei Data Centers

Institute for Plasma Research Welcomes you all on

Case study: EconAqua water mist sprinkler system

WATER SPRAY EXTINGUISHING SYSTEMS

Aspirating Smoke Detection (ASD) Systems Fire Detection

Superior by Design The Kidde ADS TM FM-200 System

PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

Fixed Fire Extinguishing Equipment and Systems

THE FIXED AEROSOL EXTINGUISHING SYSTEM - FIRE JACK

Element C3.4 Fire Fighting Equipment

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

automatic FiReFighTing SYSTeMS in PainT booths

Fire Suppression Systems

Hospitals and Major Medical Centers

Minifog PressProtect Fire protection solutions for industrial presses BRANCH SOLUTION

Fire Detection systems. UniVario industrial fire detectors for every job

Technologies Hazard management system. Inveron Hazard management system

Extinguishing water technology Minimax Mobile Services

CLEAN AGENT SYSTEMS. TABLE 1 Agents Recognized in NFPA 2001

Portable Fire Extinguishers

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

Fire and Extinguishing Tests on Computer Equipment

Hazardous Goods Warehouse. VOSSCHEMIE GmbH. Preventive Fire Protection. Case study

Thermal Oil Heating System. Heat Recovery System. Member of the

CARBON DIOXIDE CO 2 Industrial fire suppression systems

Solutions for internal vessel cleaning

POLY extinguishing systems. The high-performance, unique, and versatile extinguishing system for initial, effective fire fighting.

DESIGNER AND SUPPLIER OF MARINE FIRE FIGHTING SYSTEMS

Dry ice cleaning with COOLMASTER

PROTECCIÓN DE RIESGOS ESPECIALES AUTOMATIC FIREFIGHTING SYSTEMS IN VEHICLES. con tubo de detección

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

PRICELESS PROTECTION INERGEN Clean Agent Fire Suppression Systems

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Minifog EconAqua Water mist sprinkler systems

(Material correct at 1/11/2011)

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

CARBON DIOXIDE FIRE EXTINGUISHING SYSTEM

Fire Prevention Systems

EXTINGUISHING WATER TECHNOLOGY

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Watermist Systems. Versatile, Affordable Water Mist Fire Suppression. your TRUSTED partner in fire safety

Creating a safer world!

Fire protection for buildings

ORDINANCE FOR TECHNICAL SPECIFICATIONS PERTAINING TO AEROSOL TYPE EXTINGUISHER APPLIANCES

Fireward Fixed Fire Fighting System. For Open Areas & Enclosed Risks fireward.co.uk

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

SPECIFICATION: CARBON DIOXIDE ENGINEERED FIRE SUPPRESSION SYSTEM

TRUSTED PERFORMANCE. Carbon Dioxide Fire Suppression Systems

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

BASCO TYPE ES EXTENDED SURFACE PLATE FIN HEAT EXCHANGERS. ...world leaders in heat transfer technology

Fixed Fire Suppression. Protec. Protec Fire Detection plc. Fixed Fire Suppression Solutions ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE

MS SERIES ROLL COMPACTORS

Transcription:

GAS EXTINGUISHING SYSTEM INERT GAS Argotec with carbon dioxide Safe for certain.

PPLICATIO VERSATILE Reliable extinguishing Fighting fires quickly and effectively is the strong point of Argotec extinguishing systems with carbon dioxide. The extinguishing effect of carbon dioxide is due to the fast displacement of oxygen from the source of the fire the fire is smothered suddenly. The high heat binding capacity of the carbon dioxide causes the withdrawal of energy from the source of the fire, which enhances the extinguishing effect. Possible only with carbon dioxide Argotec extinguishing systems with carbon dioxide are especially well-suited for high risk areas, where in case of a fire it is necessary to keep the protected objects available and functioning, to minimize operational interruptions after a fire, to prevent reactions between the burnt material and the extinguishant, to prevent damage from the extinguishant itself and to ensure effective extinguishing for objects in areas with difficult access (3-D extinguishing effect). Argotec extinguishing systems with carbon dioxide, due to their special extinguishant properties, feature advantages over other inert gas extinguishing systems: Even freestanding objects in a room can be protected. The liquefied carbon dioxide forms a thick aerosol cloud in the flooding zone. Special local application nozzles put the extinguishant precisely at the object to be protected.

GAS EXTINGUISHING SYSTEM INERT GAS Due to its outstanding properties, the Argotec extinguishing system with carbon dioxide is the ideal fire protection solution for many areas of application. Typical areas of application for the Argotec extinguishing system with carbon dioxide are: switching and control systems turbines transformers and substations warehouses for hazardous materials machine tools and special metal processing systems paint and varnish manufacturing and processing areas painting and powdercoating booths (ESTA) hydraulic systems false floors and cable shafts silos and dust filters printing machines engine test benches and ship engine compartments computer and telecommunication systems and facilities medical facilities control rooms data archives art objects Optimized and individually customized The required quantity of extinguishant depends on the volume and surface of the protection zone, the quality (e.g. gas impermeability) and the type of assets to be protected. The size of the pipe network and the location of the extinguishing nozzles are based on the risk area, while the extinguishing nozzles themselves are evenly distributed throughout the entire flooding zone. For the protection of special facilities, the nozzles are installed directly within the object, such as in electric switching cabinets, false floors for cables or machine tools. If several flooding zones are connected to a common extinguishant supply, the gas is released for each zone via selector valves. With more or less pressure The carbon dioxide is supplied in high-pressure cylinders or low-pressure vessels. The optimum supply method depends on the quantity of extinguishant required and the particular circumstances.

TORAGE ALWAYS STAND-BY Supply of extinguishant in high-pressure steel cylinders The high-pressure steel cylinders are consolidated into one cylinder bank at the installation location in special frames with independent suspension. Arranged in one or more rows, surprisingly large supplies of extinguishant can be stored in a very small space. The special frames can easily be adapted for extended protection zones or quick replacement of individual cylinders. Each cylinder suspension is also a weighing unit, which automatically indicates minimum leakage of extinguishant. Flooding zone 1 (room protection computer room) Flooding zone 2 (room protection data archive) Cylinder bank Release and time delay device Selector valve Changeover valve Pneumatic release device Fire detection and control panel Safety valve Pneumatic door release unit Pneumatic horn Electric horn Room protection nozzle Fire detection element Disable device

GAS EXTINGUISHING SYSTEM INERT GAS Supply of extinguishant in low-pressure vessels If large quantities of extinguishant are needed for the overall safety concept, a low-pressure vessel is recommended especially on grounds of economy. The liquefied carbon dioxide is stored in this vessel at a temperate of approx. 20 C and at an operating pressure of approx. 20 bar. A cooling unit provides for a constant low temperature. The operating costs are minimized by an optimum insulation design. The supply vessel is mounted on a calibratable electronic weighing unit, which constantly displays the actual weight and therefore any potential loss of extinguishant due to leaks. Flooding zone 1 (room protection warehouse) Flooding zone 2 (local application printing machine) Low-pressure vessel with weighing unit Cooling unit with control device Safety valve with changeover valve Valve of pneumatic pilot pipe Pneumatic control device Fire detection and control panel Electric stop push button Electric manual push button release Door release unit Pneumatic horn Electric horn Room protection nozzle Local application nozzle Fire detection element Main shut-off valve Safety valve Selector or pilot control valve

ENEFITS NATURALLY FREE OF RESIDUE Numerous advantages Suitable both for the protection of rooms and of free-standing objects. Carbon dioxide is a natural component of the ambient air and is therefore readily available. Extinguishes without residue and without affecting the protected objects. Chemical reactions as a result of extinguishing are practically impossible. The extinguishant is electrically nonconductive and is therefore suitable also for protecting electric system components. The homogeneous distribution of extinguishant and the fast concentration buildup provide for optimum effectiveness. After a fire, there is no extinguishant residue and therefore no cleanup expense. The extinguishing effect is ensured even at low ambient temperatures. Documented reliable extinguishing provides maximum protection of assets. The system technology for the components has been tried and tested for decades. The modular, multi-zone system can easily be adapted for nearly any renovation or expansion measures. Argotec systems with carbon dioxide allow particularly space-saving extinguishant storage, especially with low-pressure vessels. After a fire, the extinguishing system is soon ready for operation again, at a low cost. Approvals by certified test authorities and the compliance of the design with national standards ensure acceptance by insurance companies and building authorities. If installed, insurance companies grant rebates on fire and fire business interruption insurance. Minimax is fully certified: including the components, systems, production and quality management system, in addition to the company itself as the installer of fire protection systems.

GAS EXTINGUISHING SYSTEM INERT GAS Danger detected The control and monitoring of the Argotec extinguishing system with carbon dioxide is achieved by the Minimax fire detection system. Fire detectors monitor the protected zone. If the system detects smoke, an excessive rise in temperature or flames, the fire detection control panel initiates the extinguishing process. Safe is better The extinguishing process with carbon dioxide reduces the oxygen in the air in the protected zone significantly below the natural level of 21 Vol.-%. Carbon dioxide in concentrations that can extinguish fires can be harmful to life, and therefore special safety measures are installed. The extinguishing process will not start until after a pre warning time, so that there is sufficient time to leave the room. All warning components are provided twofold and are connected to different power sources. Minimax inert gas extinguishing systems are designed, produced and installed in compliance with national and international guidelines and standards a guarantee for quality and your safety.

YSTEM ARGOTEC The compact solution: The compact extinguishing system for local application In compact extinguishing systems, all function-relevant components are combined with various functions in a single unit and accommodated in a protective cabinet, where they are protected from dust, moisture and mechanical damage. A compact extinguishing system consists of a frame with freely suspended extinguishing gas cylinders, which are connected via pressureproof hoses with the manifold, including weighing units with electronically monitored leakage indicators and an electromagnetic extinguishant release. A fire detection control panel integrated in the front door is connected with the detectors, which react to heat or smoke, and activates the extinguishing unit in the event of a fire. The Minimax compact extinguishing system can be placed in the immediate vicinity of the object to be protected and can quickly be connected with the cable and pipe network via standard connections. The high degree of pre-fabrication and the simple and fast installation make the Minimax compact extinguishing system an interesting and cost effective alternative to conventional systems for many objects, such as machine tools, switching cabinets or server cabinets. Functional readiness and operational safety Neuralgic functions and components of the extinguishing system, such as the extinguishant quantity, shut-off, release and distribution units, are monitored to ensure the constant functional readiness of the extinguishing system. The Minimax service department checks the operability of the extinguishing system at regular prescribed intervals and restores the operational readiness of the system after a fire without delay. Minimax GmbH & Co. KG Industriestrasse 10/12 D-23840 Bad Oldesloe Phone: +49 4531 803-0 Fax: +49 4531 803-248 E-mail: info@minimax.de www.minimax.de Nr. S 89201 PB09Ce_01/12.03/3/06.07/HA Printed in Germany