Installation plan PG 8581 PG 8582 PG en - US

Similar documents
Installation Plan. Laboratory Glassware Washer. en US PG 8583 CD. M. Nr

Installation plan: PG Mat. no Version 00 US

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation Plan. Professional Dishwasher PG Mat. no.: en - US

Installation plan. Washer disinfector. en AU, NZ PG 8583 CD. M. Nr

Installation plan: PG 8581 PG Mat. no Version 02 GB, IE, AU, NZ

Installation Plan Washing Machine PW 811 PW 814 PW 818

Installationsplan / Installation plan PG 8059

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Installationsplan / Installation plan PG 8056

Installation plan Commercial Washing Machine PW 413 PW 418

Tumble dryer PT 5135 C PT 7135 C. en - GB. Installation plan

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

Tumble dryer PT 5136 PT en - GB. Installation plan

Installationsplan / Installation plan PW 6161 EL

G 7883 CD Laboratory Glassware Washer. Analytical Cleaning, HEPA-Filtered Drying

Installation Specifications Laundry Care System

G 7883 Laboratory Glassware Washer. Analytical Cleaning, Compact Design

PG 8535 Perfect Reprocessing

Installation plan Heat pump dryer PT 8203 SL WP

PureLine Plumbed 24 Combi-Steam Oven

ContourLine Plumbed 24 Combi-Steam Oven

PureLine Plumbed Combi-Steam Oven

Installation manual Washer extractor

Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information.

PureLine Plumbed Combi-Steam Oven

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

G 7804 Laboratory Glassware Washer. Simplified Control, Miele Quality

Dishwasher Installation Manual

Installation, Operating and Servicing Instructions

hinge right B 1 85 cm + 6,5-7 cm max. height of the device feet B cm B 3 85 cm D 2 75 cm (with a maximum opening angle of 170 )

SCHWAN INSTALLATION GUIDE

Professional Laundry Solutions

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Installation Instructions

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Marco Beverage Systems Ltd.

Horizon Ice Machine Installation Instructions to Ice Storage Bin Top-mount Applications

PerfectCool Freezer FNS ie

Installation Instructions

Viking Installation Guide

Issue 4 Oct Panamatic Top loading Maxi & Optima 3 Installation

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

PRE-INSTALLATION GUIDE

SAVE THESE INSTRUCTIONS

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Removing shipping locks

WARNING WARNING. CT Express CTX4-10E CTX4-10EVH CTX4-10EC. Installation. Combitherm Combination Oven/Steamer

Installation recommendations. Washer-extractor PW 6080 EL AV/LP. en - GB Mat. no / 04

Laboratory Glassware Washer G 7804

Installation instructions for the T 9820 Gas Dryer

ContourLine Plumbed Combi-Steam Oven XXL

PerfectCool Bottom Mount Refrigerator KFNS ide

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

INSTALLATION GUIDE NZ AU C

G 7825 Laboratory Glassware Washer. Compact Design, High Throughput

Operations Manual. Part Number: For Research Use Only

PureLine Plumbed Truffle Brown Combi-Steam Oven XXL

PerfectCool Freezer FNS ie

AD-410 Models AD-410 NON-TILT* 1 DOOR GAS MODEL AD-410 NON-TILT* 1 DOOR STEAM MODEL

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

Installation & Operators Manual. The Classeq Pass Through Range

USER MANUAL/Installation Instructions LRV-4

The Classeq under counter range

STR-600 Impact Dryer

Wash Baskets & Machine Accessories. For use in Miele Large Chamber Washers Models PG 8527 & PG 8528

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Installation Instructions

Green&Clean Hood Type Dishwasher with Drain Pump & Detergent

Air-to-Water Hydromodule + Tank WH-UX12FE5 WH-UD12FE5 WH-UD16FE5. Destination Europe WARNING

DOMESTIC STEAM GENERATOR Installation Instructions

Laboratory Glassware Washer PG 8527 / PG 8528

Glass and Dishwashers AMX / AUX Series

Horizon Ice Machine Models with RIDE Technology Installation Instructions for Vision

LC1350 Level Controller

The Classeq pass Through range

PerfectCool Bottom Mount Refrigerator

MovinCool Classic and Classic Plus Series. The Portable Spot Cooling Solution

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

HWD-2110 Hot Water Dispenser

Installation manual Washer extractor

Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information.

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Perfection in Laboratory Glassware Reprocessing PG 8536

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Installation Instructions

MIX Boiler & Font Range Service Manual

Coffee Machine Zia series

Installation & Operators Manual

Installation Instructions

green&clean multi-rinse Rack Type, Energy Saving Device, medium

Rev B, 9/2/2009. Kodiak Chiller Overview

Countertop and Freestanding Ice and Water Dispenser with Chewblet Ice Machine 7CI100A, 7FS100A, 15CI100A, 15FS100A

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

P/N CC-100. Coolant Circulator. Operation manual

Transcription:

Installation plan PG 8581 PG 8582 PG 8583 It is essential to read the operating instructions as well as the service documentation before the machine is installed or used for the first time. en - US M.-Nr. 10 548 580

Installation notes Installation requirements Surrounding area Plumbing Installation should be carried out by authorized installers in accordance with valid regulations, relevant standards and health and safety codes. The machine must be commissioned and operators trained in its use by Miele Service or by an approved Miele Partner only. Only a Miele service technician is permitted to carry out the startup procedure. Condensate can build up in the area surrounding the machine. Any cabinetry and fixtures in the room must be suitable for such an environment. If the machine is installed under a countertop (built-under model), a stainless steel panel must be installed above the door opening to provide protection from steam. The stainless steel panel can be ordered from Miele Service. The cold water, hot water, demineralized water and drain water can be connected directly without a non-return valve. Use the supplied Y-adapter if only one cold water connection is available. The non-return valves of the water pipes must be easily accessible. Requirements for demineralized water system Electrical connection Equipotential bonding and grounding Unpressurized demineralized water system requires the installation of an external booster pump, which can be requested through Miele Service. Pump installation must be carried out by Miele Service. Connection to the electrical supply must be carried out in accordance with local and national safety regulations. The power cord must be protected from the risk of thermal damage. It is recommended to make electrical connections via a plug and socket so that electrical safety checks can be carried out easily. For hard-wired machines this must be via a main switch to be provided on site, which must completely isolate the machine from the power supply with a contact gap of at least 1/8 (3 mm). The plug and socket as well as the main switch must be easily accessible after the machine has been installed. For added safety the machine should be protected with a residual current device with a trip current of 30 ma. If necessary, an equipotential bond with good contact connection must be provided in accordance with all appropriate national and local regulations. Equipotential bonding and grounding must be completed before the machine is commissioned. 2 PG 8581 / PG 8582 / PG 8583

Installation notes Connecting the external dosing system Liquid process chemicals: position of external containers Communication module Up to two dispensing systems for liquid process chemicals can be connected to the rear panel of the machine. The instructions below regarding machine model must be observed: PG 8581: not available PG 8582: 1 connection PG 8583: 1 or 2 connections The liquid process chemicals container for external dispensing must be installed next to or underneath the machine. Place the container next to the machine on the floor or in an adjacent cabinet. Do not position the container above the machine. The dispenser hose must not be kinked or trapped. An RS 232 module is available as an option to facilitate Process Documentation together with the PRT 100 printer. PG 8581 / PG 8582 / PG 8583 3

Dimensions AW Drain connection NW Network and printer connection (optional) DK Cold water connection, steam condenser PA Equipotential bonding DS External dispensing system connection VE Demineralized water connection EL Electrical connection WW Hot water connection KW Cold water connection 4 PG 8581 / PG 8582 / PG 8583

Dimensions AW Drain connection NW Network and printer connection (optional) DK Cold water connection, steam condenser PA Equipotential bonding DS External dispensing system connection VE Demineralized water connection EL Electrical connection WW Hot water connection KW Cold water connection PG 8581 / PG 8582 / PG 8583 5

Dimensions Machine with and without lid Machine with lid (standard) Machine without lid 6 PG 8581 / PG 8582 / PG 8583

Technical data Electrical connection PG 8581, PG 8582 Voltage (default) 2 AC 208V 60 Hz 2 AC 208V 60 Hz Rated load 6.2 kw 6.2 kw Fuse rating 2 pole 30 Amp 2 pole 30 Amp Power cord, cross-section min. 3 x AWG 10 3 x 5.2 mm² Length of power cord (UL 921) with plug approx. 5'9'' approx. 1.8 m Electrical connection NEMA L6-30 NEMA L6-30 Voltage (convertible) 3 AC 208V 60 Hz 3 AC 208V 60 Hz Rated load 6.2 kw 6.2 kw Fuse 3 pole 20 Amp 3 pole 20 Amp Power cord, cross-section min. 4 x AWG 12 4 x 3.3 mm² Length of power cord (UL 921) with plug approx. 5'9'' approx. 1.8 m Electrical connection NEMA L15-20 NEMA L15-20 PG 8583 Voltage (default) 3 AC 208V 60 Hz 3 AC 208V 60 Hz Rated load 6.2 kw 6.2 kw Fuse rating 3 pole 20 Amp 3 pole 20 Amp Power cord, cross-section min. 4 x AWG 12 4 x 3.3 mm² Length of power cord (UL 921) with plug approx. 5'9'' approx. 1.8 m Electrical connection NEMA L15-20 NEMA L15-20 Voltage (convertible) 2 AC 208V 60 Hz 2 AC 208V 60 Hz Rated power 6.2 kw 6.2 kw Fuse rating 2 pole 30 Amp 2 pole 30 Amp Power cord, cross-section min. 3 x AWG 10 3 x 5.2 mm² Length of power cord (UL 921) with plug approx. 5'9'' approx. 1.8 m Electrical connection NEMA L6-30 NEMA L6-30 Cold water connections Use supplied Y-adapter if only one water connection is available. Max. temperature 68 F 20 C Max. water hardness 73 gpg 70 dh Recommended flow pressure 29 psi 200 kpa Minimum flow pressure with extended intake time 14.5 psi 100 kpa Max. pressure 145 psi 1,000 kpa Flow rate 2 gal/min 7.5 L/min Connection Thread Length of cold water inlet hose 5' 7" 1.7 m Length of steam condenser inlet hose 5' 7" 1.7 m PG 8581 / PG 8582 / PG 8583 7

Technical data Hot water connection Max. temperature 150 F 65 C Max. water hardness 73 gpg 70 dh Recommended flow pressure 29 psi 200 kpa Minimum flow pressure with extended water intake 5.8 psi 40 kpa Max. pressure 145 psi 1,000 kpa Flow rate 2 gal/min 7.5 L/min Connection Thread Length of hot water inlet hose 5' 7" 1.7 m Demineralized water Max. temperature 150 F 65 C Recommended flow pressure (DI pressure-resistant) 29 psi 200 kpa Minimum flow pressure with extended water intake 4.4 psi 30 kpa Maximum pressure (DI pressure-resistant) 145 psi 1,000 kpa Flow rate 2 gal/min 7.5 L/min Connection Thread Length of demineralized water inlet hose 5' 7" 1.7 m Requirements for unpressurized demineralized water systems: Minimum flow pressure with extended water intake (DI unpressurized) 1.3 psi 8.5 kpa Maximum pressure (DI unpressurized) 8.7 psi 60 kpa Hose from supply container to machine to be provided on site. Drain water Drain water temperature 199 F 93 C Length of drain hose approx. 4' 6" 1.4 m Drain hose, max. drainage length approx. 13' 1" 4.0 m Drain pump head height from floor level, max. approx. 3' 3" 1.0 m Drain hose delivery, max. 4.2 gal/min 16 L/min On-site hose connector (external dia. x l) 7/8" x 1 3/16" 22 x 30 mm Machine feet Machine feet height-adjustable 0-2 3/8" 60 mm Diameter of foot 1 3/8" 35 mm Insert for machine foot, size of thread M 8 M 8 8 PG 8581 / PG 8582 / PG 8583

Technical data Machine dimensions Height 32 7/8" 835 mm Height without lid 32 5/16" 820 mm Width 23 5/8" 600 mm Width without lid 23 9/16" 598 mm Depth 23 5/8" 600 mm Depth without lid 23 9/16" 598 mm Height of door 24 1/2" 622 mm Net weight 163 lbs 74 kg Dynamic floor load 1,200 N 1,200 N Width including transport pallet min. 26 3/8" 670 mm Depth including transport pallet min. 29 3/8" 740 mm Height including transport pallet min. 36 1/4" 920 mm Sound emissions in db (A) Sound pressure LpA, washing and drying < 70 db < 70 db Heat dissipation rate to installation room From heat emission during operation 1,194 btu/h 0.35 kwh From wash load on removal 1,365 btu/h 0.40 kwh Setup requirements Permissible ambient temperature 40-104 F 5-40 C Max. relative humidity 88 F 80 % 80 % Rel. humidity, declining proportionally up to 104 F 50 % 50 % Max. altitude above sea level 4,921' 1,500 m PG 8581 / PG 8582 / PG 8583 9

Please have the model and serial number of your appliance available when contacting Technical Service. U.S.A. Miele, Inc. National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-991-9380 Fax: 609-419-4241 www.miele-pro.com Technical Service & Support Phone: 800-991-9380 Fax: 800-220-1348 proservice@mieleusa.com Alteration rights reserved / Publication date: 2016-10-17 M.-Nr. 10 548 580 / 00 PG 8581 PG 8582 PG 8583