Capillary & Bulb Thermostatic Control & Fail-Safe Limit

Similar documents
Frost Protection Thermostat

Powers Controls ET 134 Low Temperature Detection Thermostat

TC-5231 Series, TC-5232, & TC-5241 Series

Mounting and Operating Instructions EB 2231 EN

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Powers TM Controls ET 134 Line Voltage Room Thermostats

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

TEMPERATURE & PRESSURE CONTROLS

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Powers Controls Low Temperature Detection Thermostat

Tubular Industrial Process

SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90

Duct electric heater with temperature controller

INDEX APPLIANCE GAS WATER HEATER CONTROLS 150 ELECTRIC WATER HEATER THERMOSTATS 151 SNAP DISC CONTROLS/LIMITS/SWITCHES 152 GAS DRYER VALVES 153

Frost Units for air temperature monitoring

Duct electric heater with heating. capacity from 0.6 kw up to 2.4 kw and an integrated. temperature controller

59T, 66T Series Electric Water Heater Controls

A11 Series Low Temperature Cutout Controls

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Summer Breeze Heater Service Manual

AirV Standard-Profile RV Air Conditioning

Series A28 Two stage Thermostats. Feature and Benefits

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Heatrix Electric Duct Heater HXOB Installation Instructions

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Ball-Type Faucet. Handle. Set screw. Adjusting ring. Cap. Spout. Cam Tab. Rubber cam seal Ball Rubber inlet seal Spring

The T6140A,B Remote Bulb Temperature Controller

CR1 Series Triton Corrosion Resistant Washdown Heaters

THERMOSTAT series TM10

For Technical Service Telephone Facsimile

Commercial Refrigeration Catalog

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Electric Heat - Air Curtains

Thermostat KPU. Data sheet

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

LIFTAIRE II ELEVATOR AIR CONDITIONER

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

270XT Freeze Protection, IP30

INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

Thermostat RT. Data sheet

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

Introduction to Flow Switch

ASME Packaged Indirect Fired Water Heater

Tubular Industrial Process

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

temperature Controllers

y Small dimensions. Easy to install in refrigerated counters or cold rooms

Polaris S-Series. Ducted Chimney Cabinet VERSITILE ADAPTABLE RUGGED SLEEK

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

Indirect Fired Water Heater

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

Data sheet Thermostatic sensors type RA 2000

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Electronic Dual Cylinder Thermostat Installation Instructions

Pressure switch KPU. Data sheet

Davies Is Your #1 Source For Temperature Controls

13-1. Temperature Regulator

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

59T, 66T Series Electric Water Heater Controls

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Serenity Series Auto Sensing Everything Bathroom Fan

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

ETN-24-SUPER-PROG (US Program - Celsius)

ELECTRONIC HUMIDISTAT: H200

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Industrial Air Heaters

Ceiling swirl diffusers

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Ceiling swirl diffusers

DESIGN GUIDELINES. THERMAL building SOLUTIONS

ELECTRIC SPA-PAK HEATER INSTALLATION & OPERATING INSTRUCTIONS

bring value to your space

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Flush-mounted room thermostats

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Troubleshooting Guide

45 Commerce Ave., Unit #2 South Burlington, VT tel: fax:

Fan Heater SW02 Quiet fan heater for connection to water in small buildings

A19, A28 Series Thermostats for Agricultural Buildings

Duct Temperature Sensors

Wiring Instructions. High-Capacity Steam Humidifiers

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

THERMASREG TR 040 THERMASREG TR 060

Installation, Operation & Maintenance Instructions Document Ref:

Transcription:

HCE + HDS HCE HLE Capillary & Bulb Thermostatic Control & Fail-Safe Limit Control & limit thermostats designed with flexible installation practice in mind, utilizing a rugged steel housing and covering a wide range of temperature applications. Particularly suited to environments requiring a high level of protection under fire conditions such as in ceilings and other enclosed spaces. HCE HLE HLD Control thermostats for surface mounting with the capillary & bulb freely positioned external to the housing or duct mounted in combination with HDS duct sheath Fail-safe limit thermostats for surface mounting with the capillary & bulb freely positioned external to the housing or duct mounted in combination with HDS duct sheath Fail-safe limit thermostats type HLE supplied complete with HDS00250 duct sheath HDS00125 Duct sheath, 125mm (approx 5 ) HDS00250 Duct sheath, 250mm (approx. 10 ) Applications Return plenum mounting in common areas such as lobbies and corridors On/Off control of electric heating On/Off control of 2 position valves for heating or cooling coils High temperature limit protection Remote indication of temperature conditions or alarm status

Design The housing is constructed from painted 1mm steel and features a versatile base that may be used for duct or wall mounting. For duct mounting, a 125mm or 250mm sensing-bulb support sheath is available separately. Provision is made at one end for a 20mm cable gland or conduit adapter. The housing is designed so that it may be installed with the cable entry at the top or the bottom. A 20mm hole is also provided in the base plate for fitting of the sensing bulb support sheath when used for duct applications. This hole may alternatively be used as a rear cable entry point. The sheath fixing holes are common to those of the base plate. The sensing bulb support sheath is constructed from perforated and galvanized 1mm steel. The perforations enable good airflow across the sensing bulb to ensure the best possible time constant for the control or limitation action of the thermostat. Ample space is provided in the housing for easy connection of cables and also for storage of unused capillary length, thereby enabling simplified ordering, as standard capillary lengths may be used for most applications. Operation HC thermostats utilize a liquid filled sensing bulb and bellows acting upon SPDT contacts for the automatic on/off control of the load or for remote indication. The desired temperature setting is made by way of manual adjustment of the external dial. The SPDT contacts operate when the set-point is reached. HL limit thermostats utilize a liquid filled sensing bulb and bellows acting upon SPST or SPDT contacts for automatic disconnection of a load without automatic reconnection. Reset is done manually by pressing the reset button which is accessed by unscrewing the reset button cover. The HL series is fail-safe in the event of capillary breakage. In such a case the contacts will operate to disconnect the load. To ensure the integrity of the fail-safe function, the setting of the HL series limit thermostats should not be adjusted outside of the design setting range under any circumstances. Range Selection Other versions are available on request! Order Code Description Mounting* Setting Range ( C) Differential ( C) Tollerance ( C±) Contacts Capillary (mm) HCE940030 Control thermostat Wall 0 40 3 2 SPDT 1000 HCE940010 Control thermostat Wall 0 90 4 3 SPDT 1000 HCE940160 Control thermostat Wall 0 120 4 3 SPDT 1000 HLE302632 Manual reset high limit Wall 45 55 3 SPDT 235 HLD302632 Manual reset high limit Duct 45 55 3 SPDT 235 HLE341510 Manual reset high limit Wall 90 110 +0/-6 SPST 1000 HLE342196 Manual reset high limit Wall 120 fixed +0/-8 SPDT 1000 * Wall versions reqiure HDS duct sheath for direct duct mounting The indicated capillary length does not include the sensing bulb length Subject to change without notice Page 2/5

Mounting Guide The base may be mounted with the cable entry at the top or bottom Four screw fixing points are provided. The duct sheath mounting points utilize the same fixing points as the base The Multi-purpose aperture may be used for rear cable entry, as a capillary exit point or for use with the duct sheath. For applications where the capillary exits via the end of the housing, a disposable exit tab is provided which may be pressed in or removed completely to give a clear exit point that aligns with the exit slot in the top cover. Fixing holes Duct Sheath Multi-purpose aperture Capillary exit tab Cable entry Connections HC SPDT HL SPDT HL SPST Subject to change without notice Page 3/5

Dimensions HC HL Duct Sheath - HDS00250 (HDS00125 125mm in length) Subject to change without notice Page 4/5

Technical Data Thermostat HCE940010 HCE940030 HCE940160 HL_302632 HLE341510 HLE342196 Contacts: 250Vac max. Terminal 1 15(2.5)A max. 0.5A max., N.I. n/a 0.5A max., N.I. Terminal 2 6A max., N.I. 10(2.5)A max. 15(2.5)A max. Body temperature: 85 C max. 80 C max. Bulb temperature: 150 C max. 70 C max. 150 C max. 95 C max. 125 C max. 135 C max. Capillary bending radius: 5mm min. Capillary diameter: 1.5mm Bulb dimensions: 95mm x 6.5mm 92mm x 9.5mm 95mm x 6.5mm 140mm x 6mm 95mm x 6.5mm 75mm x 6.5mm Approvals: CE, DIN, EN/EC + country specific, case by case. Subject to change without notice Page 5/5