IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

Similar documents
More Precision. thermometer // Non-contact IR temperature sensors

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

More Precision. thermometer // Non-contact infrared temperature sensors

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

E instruments. General Catalog Global Smart Measurement Solutions. Bulletin GEN - ed

E instruments. General Catalog 2011 / Infrared Thermometers Calibrators Flue Gas Analysers. Global Smart Measurement Solutions

CTlaser LT/ 1M/ 2M/ CTglass

RS Pro Infrared Temperature Sensor

Infrared Temperature Sensor

SS-100. Pyrometer. Temperature Range: 800~2400

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

M15-GSL12P30 M15-GSL12P30S Heat Spy Infrared Thermometer User Manual

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

Operator s Manual. optris CT LT/ LTF/ LTH/ 1M/ 2M/ 3M/ G5/ P3/ P7. Infrared-thermometer

Raytek /Ircon Solutions Guide. The Worldwide Leader in Noncontact Temperature Measurement

More Precision. thicknesssensor // The sensor for precise thickness measurements

Raytek /Ircon Solutions Guide

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

Innovative Technology for Traditional and Challenging Applications

I/A Series 716C 1/16 DIN Temperature Controller

Dräger Flame 2500 Flame Detection

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Instruction Manual CTVM-3H3 CTVM-2L CTVM-2H CTVM-2H1 CTVM-3L CTVM-3H CTVM-3H1 CTVM-3H2 CTVM-1L CTVM-1H CTVM-1H1

Maxline 2 Thermal Imaging Solutions for Manufacturing

IRT2 Dual Laser IR Thermometer - User Guide

Spectrum Detector, Inc.

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

CT LT/ 1M/ 2M/ 3M/ G5

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Dual Laser InfraRed (IR) Thermometer

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Danfoss gas detection units

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

I/R Thermometer Gun 12:1

SPOT HIGH PRECISION PYROMETERS A PRODUCT OF THE SYSTEM 5 FAMILY. 50 to 1800 C / 122 to 3272 F QUALITY CUSTOMER SOLUTIONS

Dual Laser InfraRed (IR) Thermometer

Datasheet: K-22 LO Sensor

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

A New Standard of Excellence

1. Quick start-up guide

Complete packages with Software and Controller

Intelligent addressable fire alarm control panel

INSTALLATION AND OPERATION MANUAL FOR THE PILOTEYE 2000

Features and Benefits

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

optris CSmicro LT/ 2WLT/ 2W2M/ 3M Operators manual Infrared Sensor

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Users Manual. Visit us at

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

PUV, PIR and PFO Series BROCHURE

Dräger Flame 2500 (IR3) Flame Detection

Williamson Pro Series Pyrometer

High Temperature InfraRed Thermometer with Laser Pointer

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

62 MAX/62 MAX + Infrared Thermometer. Users Manual

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Class 1 laser beam sensor safe for your eyes

Dräger Flame 2700 (Multi-IR) Flame Detection

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Dräger Flame 2100 Flame Detection

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

02/11/2015

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Dräger Polytron 7000 Fixed gas detector

Symphony Plus Combustion instruments

FIRERAY 5000 range USER GUIDE

INSTALLATION AND OPERATION MANUAL FOR. The Flame Intensity Monitor

CompactConnect. Special Features. Digital Displays/ Input Monitoring

Features and Benefits

S304 and S305 Dust Emission Monitors. User Manual. Distributor

EasyLog Data Logger Series

optris TM Temperature Monitor for Infrared Sensors Operators manual

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

/8 DIN Level Indicator

Our photo detectors are offered for both power or energy measurements. Measure as low as a few femtojoules in energy or a few picowatts in power.

EasyLog Data Logger Series

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Class 1 laser beam sensor safe for your eyes

RTD TEMPERATURE SENSING SYSTEM

Detection, Protection, Innovation

62 MAX/62 MAX + Infrared Thermometer. Users Manual

SUPREMATouch Modular Fire & Gas Detection System

Temperature Controllers

HOBO U30 Remote Monitoring Systems

Flame Monitors BROCHURE

Danfoss gas detection units

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Transcription:

E instruments IRtech Temperature range up to 2200 C Optical resolution up to 300:1 Close focus 0,5mm 8-14µm, 1.6µm, 1µm, 2.3µm, 3.9µm, 4.2µm, 4.6µm, 5.1µm and 7.9µm Spectral response Dual laser true target pointer Analog output 4-20mA, V, Tc J/K 2 Alarms board Up to 85 C of ambient temperature without cooling Up to 1mS response time Signal processing Remote Control Display with settings USB / RS232 / RS485 / Profibus and Ethernet interface with IR Settings Windows software Bulletin IR20 LS - ed. 09-2011 IRtech Radiamatic IR20 series is an advanced infrared thermometer with split architecture using a measuring head with a separated electronics module. The standard remote control display make easy to startup and maintenance. All the settings, including emissivity, are available on panel and can be modified with built-in keyboard. The dual laser aiming simplify the alignment of the thermometer on the target identifying the real area of measurement. The laser can be powered and switched on directly by keyboard or remotely by digital interface. The temperature of the measuring head is monitored switching off the laser if over 50 C to avoid any damage. The modular capability allow to install various digital interface and a board with two relays of alarms. This will avoid to install an additional panel meter. The powerful signal processor allow to adapt the measurement to the requirement of the application. www.eigroup.biz Features are related to all models equipped with full configuration. On next pages you can find specific details.

Models Common specifications Model Temp range FF 3600mm SF 1200mm CF1 70mm CF2 150mm CF3 200mm CF4 450mm 814 75:1-50-975 C not available 16mm 0,9mm 1,9mm 2,75mm 5,9mm 814 FAST 50:1-50-975 C 9mS not available 24mm 1,4mm 3mm 4mm 9mm 100 160 L 150:1 100L : 485-1050 C 160L : 250-800 C 100 160 H 300:1 100H : 650-1800 C 160H : 385-1600 C 100H1 : 800-2200 C 160H1 : 490-2000 C 24mm 7,3mm not available 1mm 1,3mm 3mm 12mm 3,7mm not available 0,5mm 0,7mm 1,5mm 230 L 60:1 50-400 C 60mm 18,3mm 1,2mm 2,5mm 3,3mm 7,5mm 230 H 100:1 100-600 C 36mm 11mm 0,7mm 1,5mm 2mm 4,5mm 230 H1 H2 H3 100:1 H1: 150-1000 C H2: 200-1500 C H3: 250-1800 C 12mm 3,7mm not available 0,5mm 0,7mm 1,5mm L 45:1 100-1200 C not available 27mm 1,6mm 3,4mm 4,5mm 10mm H 70:1 250-1650 C not available 17mm 1mm 2,2mm 2,9mm 6,5mm 390 420 460 45:1 200-1400 C not available 27mm 1,6mm 3,4mm 4,5mm 10mm 790 45:1 0-500 C not availble 27mm 1,6mm 3,4mm 4,5mm 10mm Emissivity / Gain / IR windows : Adjustable 0.100-1.000 Working temperature: -20 to +85 C / 10-95% RH non condensing (50 C with laser on). Storage -20 to +85 C Vibration & Shock: IEC 68-2-6: 3G. 11-200Hz, any axis IEC 68-2-27: 50G, 11mS, any axis Environmental rating : IP65 (NEMA-4) Analog output : 0/4-20mA (500ohm), 0-5/10V, Tc J,K, Alarm Analog input: External emissivity, ambient temperature compensation, trigger Digital output board: Relay : 2x60V DC / 42 V ACeff; 0,4A; optically isolated USB, RS232, RS485, CAN, Profibus, Ethernet Power supply: 5..36 V DC Functions: Peak hold, Valley hold, average, extended hold, threshold and hysteresis. Electronics Dimensions Sensing head IR Settings Windows Software Ordering Code Software allows sensor setup and remote control. The real time graphic display and datalogging show the temperature trends with 1mS sampling. 26 Code Model IR20 LS IRtech IR20 includes mounting nut and bracket ACCTLFB & instruction manual. Table A Spectral response & Range ( see table above ) 814-814 FAST - 100 L - 100H 160 L - 160 H - 230 L - 230 H 230 H1-230 H2-230 H3 - L - H 390-420 - 460-790 Table B Optics ( see table above ) SF CFx FF Standard focus optic Close focus optic Far optic Table C Cable Head/Electronics ( standard 3mt ) C8-15 8/15 mt standard cable C3H-8H-15H 3/8/15 mt high temperature cable Table D Report of Calibration 0 none C EA traceable with data IR20 LS - 814 - SF - C3-0 Typical ordering code

Optics SF optics 75:1 CF1 optics 75:1 CF2 optics 75:1 CF3 optics 75:1 IRtec Radiamatic IR 20 LS 814 CF4 optics 75:1 D = Distance S = Spotsize IRtec Radiamatic IR 20 LS 100 160

Optics D = Distance S = Spotsize IRtec Radiamatic IR 20 LS 230 D = Distance S = Spotsize IRtec Radiamatic IR 20 LS

Models Base Model Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Radiamatic IR20 Type 230 T100/T300 LS 814 T75 FAST LS 8140 T50 LS 100 T150/T300 LS 160 T150/T300 LS 230 T100/T300 LS 390 T45 LS 420 T45 LS 460 T45 LS T45/T70 LS 790 T45 Classification/ special features Advanced 2,3 sensor for laser processing applications Advanced 8-14 sighting, programming keys and display Advanced 8-14 sighting and fast response time Advanced 1 sensor with laser sighting for high temp. metal applications Advanced 1,6 sighting for high temp. metal applications Advanced 2,3 sensor with laser sighting for low/ medium temp. metal applications Advanced 3,9 sighting for measurement through flames Advanced 4,2 sighting for measurement of Advanced 4,6 sighting for measurement of CO flame gas Advanced 5,1 sighting for glass temperature measurements Detector extended InGaAs Thermopile Thermopile Si InGaAs extended InGaAs Thermopile Thermopile Thermopile Thermopile Thermopile Sensing head exchageable - Advanced 7,9 sighting for thin Head cable shortening [max. 6m] [max. 6m] [max. 6m] [max. 6m] [max. 6m] [max. 6m] [max. 6m] [max. 6m] [max. 6m] [max. 6m] Thread (sensing head) M30x1 M48x1,5 M48x1,5 M48x1,5 M48x1,5 M48x1,5 M48x1,5 M48x1,5 M48x1,5 M48x1,5 M48x1,5 Spectral range 2,3 µm 8-14 µm 8-14 µm 1,0 µm 1,6 µm 2,3 µm 3,9 µm 4,24 µm 4,64 µm 5 µm 7,9 µm Temperature ranges H: 100...600 C H1: 150...900 C H2: 200...1200 C H3: 400...1800 C -40...975 C -40...975 C L: 485...1050 C H: 650...1800 C H1: 800...2200 C L: 250...800 C H: 385...1600 C H1: 490...2000 C L: 50...400 C H: 100...600 C H1: 150...1000 C H2: 200..1500 C H3: 250...1800 C 200...1400 C 200...1400 C 200...1400 C L: 100...1200 C H: 250...1650 C Temperature resolution 0,1 C 0,1 C 0,5 C 0,1 C 0,1 C 0,1 C 0,1 C 0,1 C 0,1 C L:0,1 C/ H:0,2 C 0,5 C Optical resolution H: 100:1 H1-H3: 300:1 75:1 50:1 L: 150:1/ H: 300:1 L: 150:1/ H: 300:1 L: 60:1/ H: 100:1/ H1-H3: 300:1 45:1 45:1 45:1 L: 45:1/ H: 70:1 45:1 Option: CF lens - - - - - - - - - - - Smallest spot (CF optics/ add. CF 0,7mm@ 70mm 0,9mm@ 70mm 1,4mm@ 70mm 0,5mm@ 150mm 0,5mm@ 150mm 0,7mm@ 70mm 1,6mm@ 70mm 1,6mm@ 70mm 1,6mm@ 70mm 1mm@ 70mm 1,6mm@ 70mm Smallest spot (SF optics) 36mm@3600mm 16mm@1200mm 24mm@1200mm 3,7mm@1100mm 3,7mm@1100mm 11mm@1100mm 27mm@1200mm 27mm@1200mm 27mm@1200mm 17mm@1200mm 27mm@1200mm Sighting - double laser double laser double laser double laser double laser double laser double laser double laser double laser double laser Response time (90%) 1ms 120ms 9ms 1ms 1ms 1ms 10ms 10ms 10ms L:120ms/ H:80ms 150ms Accuracy ±(0,3% T meas +2 C) ±1 C or ±1% ±1,5 C or ±1,5% ±(0,3% Tmeas+2 C) ±(0,3% Tmeas+2 C) ±1 C or ±1% ±1 C or ±1% ±1 C or ±1% ±1 C or ±1% ±1,5 C or ±1% 0-20mA/ 4-20mA/ 0-5V/ 0-10V/ t/c (K/J) / / plastic film temperature 0...500 C Second analog output - - - - USB/ RS232/ RS485/ Profibus/ Ethernet / / Peak/ Valley/ AVG/ Advanced hold T amb Head min. -20 C -20 C -20 C -20 C -20 C -20 C -20 C -20 C -20 C -20 C -20 C T amb Head max. 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C T amb Electronics max. 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C 85 C Functional inputs/ number / 3 / 3 / 3 / 3 / 3 / 3 / 3 / 3 / 3 / 3 / 3 External emissivity adjustment External ambient control Trigger input for reset of hold Digital I/O pins - - - - - - - - - - - Simultaneous analog and digital Alarm output alternatively to analog Additional alarm output Power supply 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC 8-36 VDC Standard cable length 3m 3m 3m 3m 3m 3m 3m 3m 3m 3m 3m Cable length options - 8/ 15m 8/ 15m 8/ 15m 8/ 15m 8/ 15m 8/ 15m 8/ 15m 8/ 15m 8/ 15m 8/ 15m 26

Mechanical Accessories 26