Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No

Similar documents
The Advance You ve Been Looking For

Fire Safety Products. Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

Fire Safety Product Catalog

Fire & Life Safety Products CATALOG

Firelite CONVENTIONAL FIRE ALARM CONTROL PANELS CONVENTIONAL PANEL W/ BUILT-IN DIGITAL ALARM COMMUNICATOR

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

Reshaping Duct Smoke Detection

Lite-Configurator Version 3.1 Readme

Vista-50P/-50PUL System Design Sheet

Reshaping Duct Smoke Detection

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

Guidelines: Proper Installation of Outdoor SpectrAlert Advance Audible Visible Devices. White Paper February 2014

Innovation that Endures

Vista-128FB System Design Sheet

Vista-20SEUL System Design Sheet

Agent Release Control Panel

Control / Communicator

NBG-12LR and NBG-12LRA

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

SECTION FIRE ALARM SYSTEMS

Full Line Catalog and Product Brochures

!+ NCA-2-TC Network Control Annunciator-2, 640-characters-Traditional Chinese Network Control Annunciator-2, Traditional Chinese $1,587.

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

good things in small packages

Addressable Fire Alarm Control Panel

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Intelligent Control Panel SLC. Wiring Manual. Document Rev: P9 7/26/2018 ECN:18-323

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Vista-10SE System Design Sheet

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

Intelligent Control Panel SLC. Wiring Manual. Document /17/2014 Rev: P4 P/N 51309:P4 ECN

AL600ULX Series. Power Supply/Charger. Installation Guide

Invitation to Bid - Bid # 3095

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Fire Alarm Control Systems Simple. Smart. Reliable.

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

30.45 Electric Release PDRP-2001

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

FireNET Plus Wiring Instructions

Desigo Fire Safety Marine Fire and Detection Equipment Models FH-2071-UM, BP-62 and USCG-HPLATE

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

July 14, 1999 DF C-100.

LifeAlarm Fire Alarm Controls

4007ES Fire Control Panels

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TrueAlert Addressable Notification Appliances

MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

ECC-50/100C. Emergency Command Center

TrueAlert Multi-Candela Notification Appliances

ECC-50/100(E) Emergency Command Center

June 10, 2002 DF C S2424

SECTION : FIRE ALARM & DETECTION SYSTEMS

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Manual Call Point-Installation efficiency, Flexibility and full compliance with latest standards are at the heart of new Indoor Call Point range.

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

LifeAlarm Fire Alarm Control Panels

Siemens: Cerberus Division

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

4007ES Fire Control Panels

MS-9200UD/MS-9200UDE

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

AL602ULADA. NAC Power Extender. Installation Guide (see 02 Application Guide for additional information) More than just power. TM. Rev.

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

BPS NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

Analog fire panels FPA-1000 Family

Addressable Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC Manual

12 Clintonville Road, Northford, CT Technical Manual MS-9200 DOCUMENT # /28/97 REV: B P/N 50428:B1 ECN

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Fire alarm system specification for multiple tenant retail buildings

Section 4: Operating Instructions

AND ARCHITECT SPECIFICATIONS

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Multiple Input and Output Modules

TECHNICAL DATA OBSOLETE

Silent Knight Device Compatibility

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

PART IV DETAILED SPECIFICATION

STATE OF NORTH CAROLINA

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

/5121/5122 TrueAlert Power Supply Installation Instructions

by Honeywell MS-9050UD(E) FireuTeALarms Fire Alarm Control Panel with DACT NOTIFICATION APPLIANCE CIRCUITS (NACS)

Transcription:

Bid Specifications Fire Alarm Equipment and Parts USA Bid No. 4120302 Equivalent Mfr. Part No. Manufacturer Equivalent Item Description 21006374 Kidde Kidde Smoke Detector 50 21006371 Kidde Kidde Smoke Detector w battery 50 BG-12LX Addressable Manual Pull Station, Dual-Action, Lexan, Key Lock 40 MCBL-7 DACT phone cords 7 Feet 40 Addressable Manual Pull Station, with BG-12L Features and BG-12LX Addressable Interface mounted inside the pull station. 40 2W-B Smoke Detector, Photo, 2-Wire, 12/24VDC, Plug-in Base 40 Smoke Detector, Photo Thermal, 2-Wire, 12/24VDC, Plug-in Base 2WTA-B w/ Built in sounder 40 2WT-B Smoke Detector, Photo Thermal, 2-Wire, 12/24VDC, Plug-in Base 40 4WT-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base 40 RFP Red Retrofit Plate (5 pack) 25 2W-B i³ Photo Detector, 2-wire, 12/24 Vdc, Photo. 20 2W-MOD2 i³ 2-Wire Loop Test/Maintenance Module. 20 2WT-B i³ Photo Detector, 2-wire, 12/24 Vdc, Photo Thermal. 20 4W-B i³ Photo Detector, 4-wire, 12/24 Vdc, Photo. 20 4WT-B i³ Photo Detector, 4-wire, 12/24 Vdc, Photo Thermal. 20 5601P 135 F (57 C) fixed and rate-of-rise. (Plain) 20 5602 194 F (90 C) fixed and rate-of-rise. 20 5603 135 F (57 C) fixed temperature. 20 5604 194 F (90 C) fixed temperature. 20 5621 135 F (57 C) fixed and rate-of-rise, dual circuit. 20 5622 194 F (90 C) fixed and rate-of-rise, dual circuit. 20 5623 135 F (57 C) fixed temperature, dual circuit. 20 5624 194 F (90 C) fixed temperature, dual circuit. 20 5451 135 F (57 C) electronic fixed & ROR heat; requires B400 series base. 20 P2R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, 30, 75,110,115 cd 20 P2R-P Horn/Strobe, 12/24V, Red, Multi-Candela 15,15/75, 30, 75,110,115 cd, Plain (No Lettering) 20 P2W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, 30,75,110,115 cd 20 P2W-P Horn/Strobe, 12/24V, White, Multi-Candela 15,15/75, 30, 75,110,115 cd, Plain (No Lettering) 20 P2RK Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30, 75,110,115 cd, Outdoor, Includes backbox 20 PC2WK White outdoor horn strobe, ceiling mount 20 MHR Mini Horn, Red 20 MHW Mini Horn, White 20 Page 1 of 8

SPSCR Ceiling, Red, Selectable Candela, Speaker/Strobe 20 RFPW White Retrofit Plate (5 pack) 20 BB-STD Standard 4 square box. 20 WBB Weatherproof Backbox, Red. 20 MDF-300 Same as MMF-300, w/one additional Style B/D (Class A/B) Initiating Device Circuit 20 MMF-300 Addressable Monitor Module, One Style B/D (Class A/B) Initiating Device Circuit for Monitoring N/O Contact Devices, includes Polling LED 20 MMF-301 Device Circuit for Monitoring N/O Contact Devices, Does Not Include a Polling LED 20 MMF-302 Device Circuit for Monitoring Compatible 2-Wire Smoke Detectors, includes Polling LED. Refer to the Fire-Lite Alarms Device 20 I300 Isolator Module -- Required for Style 7 (Class A) SLC 20 BG-12LA Dual action, Lexan, Red, terminals, Key lock, Auxiliary Contacts 20 Contacts, Listed for outdoors using a WBB, or SB-I/O outdoor BG-12LAO Backbox. 20 BG-12LAOB Same as BG-12LAO, includes a SB-I/O outdoor Backbox 20 BG-12LO Dual action, Lexan, Red, terminal block, Key lock, w/gasket, Listed for Outdoor Use 20 BG-12LOB Dual action Lexan station, Red, terminal block, Key lock, with Gasket and SB-I/O Outdoor Backbox, Listed for Outdoor Use 20 BG-8 Manual Pull Station, Single-Action, Aluminum, SPST 20 2WTR-B Smoke Detector, Photo Thermal, 2-Wire, 12/24VDC,Plug-in Base, w/form-c Relay 20 4WTA-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base w/ Built in sounder 20 4WTR-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base, w/form-c Relay 20 4WTAR-B Smoke Detector, Photo Thermal, 4-Wire, 12/24VDC, Plug-in Base w/ Built in sounder and Form-C Relay 20 APA451 Remote Annunciator with Piezo Sounder, Alarm & Power LED s 20 RA400Z Remote LED -- Mounts to Single-Gang Box 20 RTS451 Remote Test Station with Switch, Alarm & Power LED s 20 RTS451KEY Remote Test Station with Switch,Alarm & Power LED's, Key Reset 20 D2 InnovairFlex 2-wire conventional photoelectric duct detector, includes 2151 detector. 10 D4120 InnovairFlex 4-wire conventional photoelectric duct detector, includes 2D51 detector. 10 D4120W InnovairFlex 4-wire conventional photoelectric duct detector, includes 2D51 detector, watertight. 10 D4S InnovairFlex 4-wire conventional sensor only component 10 2D51 Replacement 4-wire head 10 EOLR-1 12 or 24 volt EOL relay module. 10 APA151 Annunciator with piezo, alarm and power LED s. 10 RTS151KEY Remote test station; with switch, alarm and power LED s, key reset. 10 A77-AB2 i³ Retrofit Adapter Bracket. 10 STI9713 S.T.I. Steel Web Stopper for Photoelectric Smoke detector 10 STI1280 S.T.I. Back Plate for Stopper II Series 10 Page 2 of 8

STI1210D S.T.I. Horn Strobe Cover, surface mount. 10 STI1221D S.T.I. Strobe Cover, surface mount. 10 CHR Chime only; 12/24 volt; Red 10 CHW Chime only; 12/24 volt; White 10 CHSR Chime/Strobe; 15,15/75,30,75,110 Multi-Candela, 24 volt; Red 10 CHSW Chime/Strobe; 15,15/75,30,75,110 Multi-Candela, 24 volt; White 10 P2RK-P Red outdoor horn strobe, plain 10 P2RH Horn/Strobe, 12/24 Volt, Red, High-candela, 135,150,177,185 cd 10 P2WH Horn/Strobe, 12/24 Volt, White, High-candela, 135,150,177,185 cd 10 P2WH-P Horn/Strobe, 12/24 Volt, White, High-candela, 135,150,177,185 cd, Plain (No Lettering) 10 P2RHK Horn/Strobe, 12/24 Volt, Hi Candela, 135,150,177,185 cd, Red Outdoor, Includes backbox 10 P4R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, P4W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, P4RK Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor, Includes backbox 10 P4WK White outdoor horn strobe, 4 wire 10 P4RK-R Replacement Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor 10 PC2R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, PC2R-P Horn/Strobe, 12/24V, Red, Multi-Candela 15,15/75, 30,75,110,115 cd, Plain (No Lettering) 10 PC2W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, PC2W-P Horn/Strobe, 12/24V, White, Multi-Candela 15,15/75, 30,75,110,115 cd, Plain (No Lettering) 10 PC2W-SP Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75,30,75,110,115 cd, Fuego 10 PC2RK Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor, Includes backbox 10 PC4R Horn/Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75, PC4W Horn/Strobe, 12/24 Volt, White, Multi-Candela 15,15/75, PC4WK White outdoor horn strobe, ceiling mount, 4 wire 10 PC4RH Horn/Strobe, 12/24 Volt, Red, High-candela, 135,150,177,185 cd 10 SPRK Wall, Outdoor, Red, Speaker only 10 SPWK Wall, Outdoor, White, Speaker only 10 SPSRK Wall, Outdoor, Red, Selectable Candela, Speaker/Strobe 10 SPSRK-PG Wall, Outdoor, Red, Selectable Candela, Speaker/Strobe, Portugese 10 SPSWK Wall, Outdoor, White, Selectable Candela, Speaker/Strobe 10 Wall, Outdoor, White, Selectable Candela, Speaker/Strobe, SPSWK-PG Portugese 10 SPSCW-P Ceiling, White, Selectable Candela, Speaker/Strobe, Plain 10 SPSCWK Ceiling, Outdoor, White, Selectable Candela, Speaker/Strobe 10 Ceiling, Outdoor, White, Selectable Candela, Speaker/Strobe, SPSCWK-PG Portugese 10 Page 3 of 8

SPSCWK-SP Ceiling, Outdoor, White, Selectable Candela, Speaker/Strobe, Spanish 10 SPBBSC Ceiling, Back Box Skirt, Red 10 SPBBSCW Ceiling, Back Box Skirt, White 10 SA-WBB Weatherproof Back Box - Wall Mount, Red 10 R-10T Relay, SPDT, Multivolt, Track mount 10 R-10E Relay, SPDT, Multivolt, Track mount, metal enclosure 10 R-14T 4-Gang Relay, SPDT, Multivolt, Track mount 10 R-14E 4-Gang Relay, SPDT, Multivolt, Track mount, metal enclosure 10 R-20T Relay, DPDT, Multivolt, Track mount 10 R-20E Relay, DPDT, Multivolt, Track mount, metal enclosure 10 R-24T 4-Gang Relay, DPDT, Multivolt, Track mount 10 R-24E 4-Gang Relay, DPDT, Multivolt, Track mount, metal enclosure 10 PR-1 Relay, SPDT, Multivolt, 24VDC, 24/115VAC 10 PR-2 Relay, SPDT, Multivolt, 10-40VDC 10 PR-3 Relay, SPDT, Multivolt, 10-40VDC, Redundant power input 10 HRB1224 DPDT Relay 12/24VDC 5A 120 VAC 10 HRB610 SPDT Rly 6Pk 120AC/12/24VDC10A 10 411 3 Channel, dual line slave DACT. Requires PRO-411 programmer. 10 4 Channel dual line slave programmer DACT, Form-C Relay and 411UD Up/Download Capability. Requires PRO-411. 10 MS-10UD-7 10 Zone Conventional Fire Control Panel with 7 amp power supply. 10 MS-5UD-3 5 Zone Conventional Fire Control Panel with 3 amp power supply. 10 MS-5UD-7 5 Zone Conventional Fire Control Panel with 7 amp power supply. 10 CP355 Addressable Low-Profile Ionization Smoke Detector; includes B350LP base 10 SD355 Addressable Low-Profile Photoelectric Smoke Detector; includes B350LP base 10 SD355T Addressable Low-Profile Photoelectric Smoke Detector w/thermal Sensor; includes B350LP base 10 AD355 Photoelectric Smoke Detector and Thermal, Capable of Heat-Only alarm mode. Clip Mode Only; includes B350LP base 10 H355R Addressable Heat Detector w/rate-of-rise Thermal Sensor; includes B350LP base 10 H355HT Addressable High Heat Detector; includes B350LP base 10 BEAM355 Addressable Beam Detector 10 BEAM355S Addressable Beam Detector 10 Addressable Photoelectric Low-Flow Duct Detector, Includes Smoke D350PL Head 10 D350RPL Same as D350PL, with Built-In Relay 10 IPDACT Internet Communicator. Requires compatible FL panel equipped with on-board or optional DACT. 10 IPBRKT Used for mounting IP communicators in common enclosure for MS- 5UD-3, MS-10UD-7, MS-9050UD, MS-9200UDLS 10 IPENC Enclosure used for mounting IP communicators next to Legacy FACP enclosures 10 Page 4 of 8

411UDAC Communicator. 1 Amp of NAC power, integral battery charger, upload/download capability. Programmable using PRO-411 or PK- 10 BG12TR Lexan Trim Ring for all BG12 series Pull Stations 10 SB-10 Surface Mount Backbox 10 17007 Spare Hex Wrench 1/8 10 17003 Spare Fire-Lite Key Set (2) 10 BG-2R Surface Mounting Backbox, Red, Tapped for 1/2" Conduit 10 SB-10 Surface Mount Backbox 10 5601P 135 F (57 C) fixed and rate-of-rise, normally open 10 5602 194 F (90 C) fixed and rate-of-rise, normally open 10 5603 135 F (57 C) fixed temperature, normally open 10 5604 194 F (90 C) fixed temperature, normally open 10 5621 135 F (57 C) fixed and rate-of-rise, dual circuit, normally open 10 5622 194 F (90 C) fixed and rate-of-rise, dual circuit, normally open 10 5623 135 F (57 C) fixed temperature, dual circuit, normally open 10 5624 194 F (90 C) fixed temperature, dual circuit, normally open 10 APC-1 Protective Cover for A and AT Heat Detectors 10 302-135 135 F (57 C) vertical mount 10 302-194 194 F (90 C) vertical mount 10 302-AW-135 135 F (57 C) vertical mount, for indoor or outdoor use 10 302-AW-194 194 F (90 C) vertical mount, for indoor or outdoor use 10 4W-B Smoke Detector, Photo 4-Wire, 12/24VDC, Plug-in Base 10 DH100LP Low-Flow Duct Smoke Detector, Photo, 2-Wire, 12/24 VDC 10 A5180 Replacement DH100 Photoelectric detector board, 2-Wire 10 A5190 Replacement DH100 Photoelectric detector board, 4-Wire 10 A5061-00 Replacement DH100LP 2-wire power board 10 A5064-00 Replacement DH100ACDCI/P 4-wire power board 10 ST-1.5 Metal Sampling Tube for 1' to 2' Duct Widths 10 ST-3 Metal Sampling Tube for 2' to 4' Duct Widths 10 ST-5 Metal Sampling Tube for 4' to 8' Duct Widths 10 ST-10 Metal Sampling Tube for 8' to 10' Duct Widths 10 RA100Z Remote LED. Mounts to single gang box. 5 RTS151 Remote test station; with switch, alarm and power LED s. 5 STI9601 S.T.I. Low profile smoke detector cover. 5 STI9602 S.T.I. Steel WEB Stopper, low profile, surface mount. 5 STI9604 S.T.I. Heat detector steel cover. 5 Page 5 of 8

STI9605 S.T.I. Steel WEB Stopper, medium profile, surface mount. 5 STI9609 S.T.I. Smoke detector cover, high profile. 5 STI9610 S.T.I. Steel WEB Stopper, high profile, surface mount. 5 STI1229 S.T.I. NEMA 4X rated Stopper Dome 5 Manual Pull Station Cover, Mini-Stopper without Horn, Flush STI6500 S.T.I. Mount 5 STI1130 S.T.I. Stopper II with horn, surface. 5 STI1230 S.T.I. Stopper II, no horn, surface. 5 STI3150 S.T.I. Weather Stopper II, surface mount. 5 STI3002 S.T.I. Weather gasket. 5 STI3003 S.T.I. Conduit gasket. 5 STI3100 S.T.I. Conduit spacer, surface mount. 5 SW-ALERT Amber Strobe, white housing, Multi-candela, ALERT 5 SWH-ALERT Amber Strobe, white housing, Hi-candela, ALERT 5 SPSW-ALERT Speaker Strobe, Standard cd, White, Amber Lens 5 White ceiling mount speaker strobe with clear lens and ALERT SPSCW-CLR-ALERT marking 5 SW-CLR-ALERT Strobe, Standard cd, White, Clear Lens 5 SCW-CLR-ALERT White ceiling mount strobe with clear lens and ALERT marking 5 HR Horn Only, 12 or 24 volt, Red, Wall Mount 5 HW Horn Only, 12 or 24 volt, White, Wall Mount 5 Horn Only, 12 or 24 volt, Red, Wall Mount, Outdoor, Includes HRK backbox 5 HRK-R Replacement Horn, Red, Wall Mount, Outdoor 5 P2WK White outdoor horn strobe 5 P2WK-P White outdoor horn strobe, plain 5 Replacement Horn/Strobe, 12/24 Volt, Red, Multi-Candela P2RK-R 15,15/75,30,75,110,115 cd, Outdoor 5 P4RH Horn/Strobe, 12/24 Volt, Red, High-candela, 135,150,177,185 cd 5 PC4WHK White outdoor horn stobe, ceiling mount, high candela, 4 wire 5 SR Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd 5 SR-P Strobe, 12/24V, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Plain (No Lettering) 5 SR-SP Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Fuego 5 SW Strobe, 12/24 Volt, White, Multi-Candela 15,15/75,30,75,110,115 cd 5 SW-P Strobe, 12/24V, White, Multi-Candela 15,15/75,30,75,110,115 cd, Plain (No Lettering) 5 SRK Strobe, 12/24 Volt, Red, Multi-Candela 15,15/75,30,75,110,115 cd, Outdoor, Includes backbox 5 SPR Wall, Red, Speaker only 5 SPW Wall, White, Speaker only 5 SPSRK-P Red outdoor speaker strobe, plain 5 Page 6 of 8

SSM24-10 24V, 10 Bell. 5 SSM24-6 24V, 6 Bell. 5 SSM24-8 24V, 8 Bell. 5 HPT6062 12/24VDC Multi-function Timer 5 ANN-80 80 Char LCD serial annunciator, Red 5 ANN-80-W 80 Char LCD serial annunciator, White 5 MS-9050UD 50 Pt Addressable panel, supports 50 modules or detectors in any combination 5 MS-9200UDLS Addressable Fire Alarm Control,198-Points on One Signaling Line Circuit (SLC) Loop, 24VDC 5 MS-9200UDLSE Addressable Fire Alarm Control,198-Points on One Signaling Line Circuit (SLC) Loop, 24VDC, Export, 220 volt 5 10103 Three-gang electrical box for mounting LCD-80F 5 MS-9600 Addressable Fire Alarm Control, 636-Points on Two Signaling Line Circuit s (SLC s), (2nd SLC optional), 24VDC 5 CMF-300 Addressable Control Module -- One Supervised, Style Y/Z (Class A/B) Notification Appliance (Bell) Circuit. 5 CRF-300 Addressable Relay Module -Built-In Two Form-C Relays 5 DACT-UD Upload / Download Digital Alarm Communicator Transmitter for the MS-9600 5 UDACT-F Universal D.A.C.T. Mounts in S2000, or MS-9200 Cabinet or ABS- 8RF or UBS-1F. Note use DACT-UD with MS-9600 Rev. 2 5 BG-12LR Dual action, Lexan, Red, terminal block, Key lock, for Agent Release Applications 5 BG-12LRA and LED Annunciation, for Agent Release Applications, Use with SBA-10 Surface Mount Backbox 5 17007 Spare HEX Wrench -- 1/8" 5 17003 Spare Fire-Lite Key 5 CO1224 Conventional Carbon Monoxide Detector, 12/24 VDC, with sounder and trouble relay; UL2075 listed 5 BEAM1224 Projected Beam Smoke Detector, Single-ended Reflected Type, Includes Trouble Relay, Transmitter/Receiver in One Unit. 4 DST1 InnovairFlex sampling tube, steel, 1 with holes 4 DST1.5 InnovairFlex sampling tube, steel, 1.5 with holes 4 DST3 InnovairFlex sampling tube, steel, 3 with holes 4 DST5 InnovairFlex sampling tube, steel, 5 with holes 4 DST10 InnovairFlex sampling tube, steel, 10 with holes 4 ETX InnovairFlex exhaust tube, steel, 1 4 TR Wall, Trim Ring, Red (5 pack) 4 TRW Wall, Trim Ring, White (5 pack) 4 TRC Ceiling, Trim Ring, Red (5 pack) 4 TRCW Ceiling, Trim Ring, White (5 pack) 4 BEAM1224S Same as BEAM1224 with Built-in Sensitivity Test Filter. 2 where there is difficulty in maintaining the set angle. When installed 6500-MMK with the transmitter/receiver unit, 6500-SMK must be used as well) 2 Grand Total Page 7 of 8

Discount off your advertised list price for all other fire alarm equipment and accessories % Page 8 of 8