Aeronex Gas Purification System Z2 Series

Similar documents
GateKeeper Gas Purification System Z2 Series for 400, 500, 600 NM 3 /HR

GateKeeper Gas Purification System Z2 Series

GateKeeper Gas Purification System Z2 Series

GateKeeper Gas Purification System SX Series

GATEKEEPER GAS PURIFICATION SYSTEM DX SERIES FOR 20, 30, 50 AND 60 NM 3 /HR

FluoroLine Electrostatic Dissipative (ESD) Tubing

twin tower desiccant compressed air dryers flow capacity: 200-9,000 scfm (340-15,300 Nm3/hr)

NT DUAL CHANNEL DISPLAY. User Guide

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

SSB Blower Purge Desiccant Dryers SSE Heat Reactivated Desiccant Dryers 220 to 10,500 scfm

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

Isco 3700ZR Sampler. Manual Set

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

vsource GAS SOURCE SYSTEMS

Compressed Air. Filtration. Balston Membrane Nitrogen Generators. 157 Parker Hannifin Corporation

NGV Fueling Station Dryers. FSD-A, FSD-T, FSD-M and MRS Series Catalog

SEMI-GAS Centurion TM Gas Source Panels/Manifolds

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)


ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

SYNRAD Technical Bulletin # 0015d

Flopurge TS. Operation Manual

SOLUTIONS. Natural Gas Dryers for NGV Fueling Stations.

OG5000 Ozone Generator Model OG5000B-A. User Manual

SOLUTIONS. Natural Gas Dryers for NGV Fueling Stations.

clean, dry compressed air

Instruction Manual. M150 Gas Reactor Column. A Issue B

Series 9000 Total Hydrocarbon Analyzer

4000TOC Sensor. Continuous On-Line Measurement Total Organic Carbon Monitoring. THORNTON Leading Pure Water Analytics

MODEL NUMBER: SRCOOL60KCW

CRYOGENIC EXPERTS, INC. World Wide Web Toll Free FOR CEXI Phone (805) Facsimile (805)

Integrated Process Solutions. Series 49. Thermal Management System

Integrated Process Solutions. Series 46 Heaters HEATER JACKETS FOR STAINLESS STEEL PIPING SIZES 1 1/2 TO 4 (NW 40 TO NW 100)

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

Flostop TS D7E and A8E. Operation Manual

HFID Heated Total Hydrocarbon Analyzer Module

Innovation in air purification unmatched air quality

Solution. Supply single or multiple GC instruments Continuous Emission and Air monitoring Mud logging application for oil industry

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

thermal management features such as temperature setpoint control, temperature ramp rate control, and process heating.

RAYCHEM NGC-30 COMPONENTS

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

REFRIGERATED AIR DRYERS SCFM. CRPC Energy Saving Series

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Series 5000 Hydrazine Analyzer Model 60002

Energy Saving Refrigerated Compressed Air Dryers DES Series 90 to 675 scfm (153 to 1148 nm 3 /h)

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Air Quality Control System

HYDROGARD Refrigerated Air Dryers HGD and DES Series

OIL/WATER SEPARATORS. Compressed Air & Process Filtration

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

Wireless DC Voltage Detector

IMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.

Titus Air Systems. TDD Series. The need for clean and dry compressed air. Energy efficiency

PNEUDRI MiDAS - Mini Dry Air System

Refrigerated Compressed Air Dryers

Global Leader in Efficiently Treating Compressed Air EXCELLENCE IN DESIGN, MANUFACTURING AND SERVICE

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

AirCel. AG Aluminum. SH Steel. Industrial Filter Housings

Using the DewTrak II Dew Point/ Humidity Transmitter

Pipeline. Medical Gas Pipeline Products

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Gas Chromatograph. Features. Continuous Analysis of Ultra High Purity Argon to ppb levels.

ANNEX I. Technical specifications for: Supply of various Trace Explosive Detection Systems

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page


Desiccant Dryers. Desiccant Dryers. Heatless Heated Purge Blower Purge Modular

Dräger REGARD -1 Control System

Refrigerated Compressed Air Dryers

Unimaster Dust Collectors

Owners Manual Model: XXL

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Desiccant Drying DRYPOINT XC. efficient low dew point heatless desiccant drying. Truth in Compressed Air.

Compressed Air Filters

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Nitrogen Generation Systems Compressed Air Dryers

Atlas Copco Stationary Air Compressors. GA30-90C WorkPlace Air System TM 30-90kW/40-125HP oil-injected rotary screw compressors

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

High Output Vacuum/Pressure Pump

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

portable gas analyser

Dräger Polytron 8200 Stationary gas detector (CatEx)

NGD8800 USER S MANUAL

STEAMPAK Series BurnerPAK BMS Burner Management Systems

Explosives Trace Detection. Innovation with Integrity. Explosives Threat Mitigation: Bruker RoadRunner. Safety & Security

Electronic Pressure Digest. Pressure and Temperature Transmitters

Refrigerated Compressed Air Dryers

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA 5-11 (5,5-11 kw/7,5-15 hp)

PET Drying Technology

Dräger Flame 2350 (UV&IR) Flame Detection

Explosives Trace Detection. Innovation with Integrity. Explosives Threat Mitigation: Bruker DE-tector flex. Safety & Security

CLEAN, DRY COMPRESSED AIR

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

~500 V AC / DC. Wireless 500 VAC/VDC Voltage Meter. The Leader in Low-Cost, Remote Monitoring Solutions. Monnit Sensor Core Specifications

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Transcription:

MICROCONTAMINATION CONTROL Aeronex Gas Purification System Z2 Series Continuous high-flow, point-of-use Extreme Clean Dry Air (XCDA ) purge gas at a low cost of ownership Advanced Technology in High-flow Gas Purification The Aeronex Gas Purification System (AGPS), Z2 series, is the latest continuous service high-flow gas purification system from Entegris. The system brings advanced technology to high-flow gas purification providing semiconductor manufacturers with an innovative, efficient, and cost-effective solution to purify purge gasses used in dry and immersion-based lithograph tools. The Entegris AGPS represents the culmination of 15 years of experience in gas purification and delivery technologies. It delivers Extreme Clean Dry Air (XCDA ) purge gas to today s scanner platforms including immersion lithography tools. XCDA is proven to be an effective and safer alternative to other purge gases for lithography applications. The new Z2 media represents the latest advancement in purification technology from Entegris, providing for outlet purity in the sub-parts-per-trillion (ppt) levels. The system applies ambient temperature purification, so heating is not required for purification. This means resource conservation and lower energy costs. The AGPS effectively and efficiently removes contaminants such as SO 2, SOX, NOX, H 2 S, H 2 O, CO 2, siloxanes, ammonia, amines, acid gasses, alcohols, and nonmethane hydrocarbons from CDA (air) gas. FEATURES & BENEFITS Power failure will not damage the purification system Completely automatic operation saves time, increases reliability Purifies to sub-ppt (parts-per trillion) levels Low pressure drop means no changes to inlet pressure are required Includes inlet and outlet process gas pressure transducers Self-regenerating purifiers provide the lowest cost of ownership Ambient temperature purification means lower energy costs and resource conservation CE and SEMI certified Start-up service is provided, making it easy to integrate the unit Ethernet connection allows for remote monitoring capability Designed for easy field maintenance and upgrades Available worldwide through Entegris global infrastructure APPLICATIONS Photolithography FOUP cleaning and purging Stocker cleaning and purging Other applications that require XCDA purge gas MODELS AVAILABLE Model AGPS2CZ2 Description Enclosed model for use with applications requiring a flow rate up to 2,000 slm AGPS2DZ2 Enclosed model for use with applications requiring a flow rate up to 3,500 slm

SAFETY FEATURES Feature Description AGPS2CZ2 AGPS2DZ2 Earth leakage circuit breaker Provides additional electrical protection to the system. Over temperature rise condition Monitored via thermocouple. Heaters sized to prevent runaway conditions. As a secondary precautionary device, a high-temperature hardware interlock is included on all systems. Hydrogen detector Triggers an EMO alarm and shuts down the system in the event of a gas leak of hydrogen inside the system enclosure. Rate-of-rise detector If the detector senses a rapid increase in temperature inside the system enclosure, an EMO alarm will be activated and shut down the system. EMO button When activated, power is removed from the main enclosure. The front panel and controller remain powered. Process gas flow is shut off. Remote EMO Provides input for remote EMO activation. In the event of an EMO shutdown, the system will send an output signal to an external sensing device that alerts the facility of the alarm. Remote alarm In the event of a minor alarm in the system not requiring an EMO shutdown, the system will send an output signal to an external sensing device that alerts the facility of the alarm. Visual alarm Alarm conditions will result in a visual alarm on the top of the electrical enclosure. Audible alarm Alarm conditions will result in an audible alarm. Isolated electrical enclosure Electronics are physically isolated from the main purifier cabinet in an attached electrical enclosure. PRODUCT SPECIFICATIONS Model AGPS2CZ2 AGPS2DZ2 Gases purified Media type Contaminants removed Outlet purity Operating pressure range CDA (air) Inorganic Volatile acids, volatile bases, refractory compounds, condensable organics, moisture <100 ppt H 2 O, <10 ppt volatile bases, <1 ppt all other listed contaminants 5.51 10.34 bar (80 150 psig) Pressure drop <7 psi @ 100 psig and max rated flow <10 psi @ 100 psig and max rated flow Maximum flow rate 2000 slm (120 Nm 3 /hr) 3500 slm (210 Nm 3 /hr) Gas operating temperature Outlet filtration Leak rating 15 40 C (60 104 F) ISO Class 1 (<10 particles per m 3 @ 0.1 µm, <2 particles per m 3 @ 0.2 µm) 1 10-9 atm cc/sec 2

FACILITY SPECIFICATIONS Specifications AGPS2CZ2 AGPS2DZ2 Process gas input Mechanical connection 1" female face seal 1.5" tube stub Process gas output Mechanical connection 1" male face seal 1.5" tube stub Ventilation Mechanical connection 4" duct Exhaust flow 70 cfm 150 cfm Power requirements Mechanical connection 3 pin mechanical disconnect Power requirements 200 240 VAC single phase Power consumption 150W at idle and online; 2000W at regen Regeneration Regen duration 24 hours for each purifier bed Regen gas output Mechanical connection Integrated into system ventilation Instrument air Mechanical connection 1 4" compression fitting Gas and pressure CDA or N 2 @ 90-125 psig Physical requirements Mounting Floor Recommended maintenance space 3 feet on all sides for minimum MTTR Shipping weight 363 kg (850 lbs) 544 kg (1200 lbs) Operating conditions 15 40 C indoor (60 104 F indoor) Humidity 10-90% RH noncondensing Note: It is the customer s responsibility to ensure that the equipment is installed according to local building code requirements. 3

DIMENSIONS Specific information on all models is available on request. Model AGPS2CZ2 1 685.8 mm (27.0 ) 2 3 914.4 mm (36.0 ) 717.3 mm (28.2 ) 4 5 6 1855.1 mm (74.2 ) 1980.6 mm (77.9 ) 1809.4 mm (71.2 ) 7 System features Item Feature Description 1 Exhaust Vent Allows ventilation 2 Process gas input Customer-supplied unpurified CDA line 3 Process gas output Purified XCDA line 4 System switch Emergency ON/OFF switch for the system 5 Touch screen For system status and interface 6 Instrument panel Contains USB interface, start/clear button and EMO button 7 Casters Casters with integrated leveling feet. System includes seismic restraint brackets. 4

DIMENSIONS (CONTINUED) Specific information on all models is available on request. Model AGPS2DZ2 1 2 889.0 mm (35.0 ) 3 1168.4 mm (46.0 ) 889.0 mm (35.0 ) 4 5 1889.8 mm (74.4 ) 6 1808.0 mm (71.2 ) 7 System features Item Feature Description 1 Exhaust Vent Allows ventilation 2 Process gas input Customer-supplied unpurified CDA line 3 Process gas output Purified XCDA line 4 System switch Emergency ON/OFF switch for the system 5 Touch screen For system status and interface 6 Instrument panel Contains USB interface, start/clear button and EMO button 7 Casters Casters with integrated leveling feet. System includes seismic restraint brackets. 5

ENCLOSURE INFORMATION The Aeronex Z2 series enclosure is designed for indoor applications only. The enclosure includes leveling feet with integrated casters and seismic restraint brackets to secure the system to the floor. Panels are removable on all four sides of the enclosure. The backup purifier compartment is accessible from a door on the front of the enclosure Aeronex model AGPS2DZ2 shown OPTIONS Available options AGPS2CZ2 AGPS2DZ2 Manual bypass valve Automatic bypass valve Automatic bypass valve with integrated GateKeeper backup purifier Moisture indicator Process gas mass flowmeter with totalizer ORDERING INFORMATION Aeronex Z2 Series Gas Purification System: part number AGPS 2 Z2 1 0 01 Media series Z2 series Flow C = 2000 slm D = 3500 slm Cabinet 2 = Standalone enclosure Generation AGPS = Third-generation Aeronex Gas Purification System Region 1= Standard Sensor 0 = No sensor Online detection 3 = Mass flowmeter with totalizer 0 = No online detection 1 = Moisture indicator Bypass 0 = No bypass 1 = Manual bypass valve 2 = Automatic bypass valve 4 = Automatic bypass valve with integrated GateKeeper backup purifier Gas 0= XCDA Reserved 01 = Default Note: Not all options are available for all configurations. Consult your local sales representative for more information and assistance to select a part number. All specifications subject to change. 6

FOR MORE INFORMATION Please call your Regional Customer Service Center today to learn what Entegris can do for you. Visit entegris.com and select the Contact Us link to find the customer service center nearest you. TERMS AND CONDITIONS OF SALE All purchases are subject to Entegris Terms and Conditions of Sale. To view and print this information, visit entegris.com and select the Terms & Conditions link in the footer. Corporate Headquarters 129 Concord Road Billerica, MA 01821 USA Customer Service Tel +1 952 556 4181 Fax +1 952 556 8022 Toll Free 800 394 4083 Entegris, the Entegris Rings Design, Pure Advantage, and other product names are trademarks of Entegris, Inc. as listed on entegris.com/trademarks. All third-party product names, logos, and company names are trademarks or registered trademarks of their respective owners. Use of them does not imply any affiliation, sponsorship, or endorsement by the trademark owner. 2007-2018 Entegris, Inc. All rights reserved. Printed in the USA 4507-5106ENT-0418 www.entegris.com