KPSW CONSOLE TERMINAL UNIT

Similar documents
CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

CLIMACIAT AIR COMPACT

Blower-YEFB-020-3R-1maxVel

Room Temperature Controller

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL DATA & SERVICE MANUAL

AOF CLIMATISEUR MONOBLOC A CONDENSATION A EAU SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

TECHNICAL DATA & SERVICE MANUAL

Room Temperature Controllers

GeoCIAT Modular. Components. Heat pump Heating only, Glycol/water mix/water. Refrigerant and hydraulic module diagram. HomeConnect control.

1. Information before installation General terms of delivery, storage and transport

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

42AM. Air heaters PRODUCT SELECTION DATA

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

FAN COIL UNITS LASER / LOW BODY / CONCEALED

TopVent Design Handbook

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

SIGMA PRISMA LOW BODY CONCEALED

QZHW Fan Coil Unit. Key features. Specifications

CAW Ceiling-mounted fan heaters for hot water

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

THERMASREG TR 040 THERMASREG TR 060

SPLIT SYSTEM AIR CONDITIONER

NEW RANGE OF WARM AIR CURTAINS

Use. For 2-pipe fan coils

Compact and silent Scroll compressors All-season operation

QTS SELECTION TECHNICAL BOOKLET

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Fan coil units EPCE04-25A

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

Room Temperature Controller

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

1. Information before installation General terms of delivery, storage and transport

AIR-CONDITIONER SERVICE MANUAL

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

TECHNICAL DATA & SERVICE MANUAL

QZB "Standard" comfort fan coil

System architecture. Air treatment Index

CASSETTE UNIT. Comfort Circle

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Quatro canal Super-powered climate control for 4-pipe systems

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: CAF94R5 CAF124R5 CAF94R

Technical documentation Fan coil unit

FREEDOM 2019.EX CZ - 21/11/18

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

UCS UCS/M UCS/H UCS900

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

High temperature air-to-water heat pumps

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Fan Coil Range HYDRONIC TERMINALS

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

HT V2 HT Split

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

RAYPAK HOT WATER & HEATING

TECHNICAL DATA & SERVICE MANUAL

Semi flush-mount room thermostat

Evaporadoras Hidrónicas

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

DIRECT DRIVE BLOWER COILS

Preliminary Release. Room Temperature

We have some on stock... GEA MultiMAXX Prompt. Unit Heaters Data & Facts. GEA Heat Exchangers / HVAC Systems

Conditioning your ambient, maximising your comfort.

Transcription:

TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November 008 0 7 - GB - 0

MARKING This product marked conforms to the essential requirements of the Directives : - Low voltage no. 006/95/EC, - Electromagnetic Compatibility no. 89/6 EEC, modified 9/ and 9/68 EEC. SUMMARY - Presentation... - Technical characteristics... - Physical characteristics... 4 4 - Description... 4 5 - Accessories... 5 - PRESENTATION. - UTILISATION Units intended for climate control in buildings and the comfort of people. Do not place the device in rooms with high humidity or exposed to projections of water.. - FUNCTIONS Cooling or heating by means of a -pipe water coil. Ventilation with filtration (built-in filter).. - APPLICATIONS These units, derived directly from direct expansion models, are characterized by: - attractiveness, - compactness (using unused spaces), - a low sound level, - various installation possibilities (floor, wall or ceiling)..4 - MODELS "-pipe" for all sizes, with wire or infrared remote control: KPSW B 5B and KPSW B 5X.

- TECHNICAL CHARACTERISTICS. - NOMINAL CONDITIONS Model Total cooling capacity () HS kw MS kw LS kw Sensible cooling capacity () HS kw MS kw LS kw Heating capacity () HS kw MS kw LS kw Air flow rate HS m /h m /s MS m /h m /s LS m /h m /s Water flow rate in cooling HS l/h MS l/h LS l/h Pressure drop on water in cooling () HS kpa in the appliance MS kpa (0 kpa = m WG) LS kpa Pressure drop on water in cooling () in the flexible tubes Short length kpa (accessory) (0 kpa = m WG) Long length kpa Pressure drop on water in heating () () kpa Power supply V/f/Hz Max. power consumption kw Max. current consumption A Hydraulic connection Sound power level HS db(a) MS db(a) LS db(a) Calculed sound pressure HS db(a) (at m indoors) MS db(a) LS db(a) KPSW.40.80.07.97.50 0.9.48.70.84 45 0.5 00 0.08 00 0.056 40 84. 4 4. 6.4 0//50 0.04 0.6 48 4 5 40 5 7 KPSW.9.40..47.80 0.95 4.07.40.05 50 0.44 40 0.9 0 0.058 550 4 9 6.6 9.9 4.4 7.7 0//50 0.046 0. 50 45 5 4 7 7 KPSW 4.60.77.06.50.48 5.0 4.0.40 675 0.88 570 0.58 0 0.09 67 50 09 5.8 9 7.4 8.8.8 0//50 0.080 0.40 54 5 40 46 4 () Air inlet: 7 C (DB) / 9 C (WB); water: inlet at 7 C, outlet at C. () Air inlet: 0 C; water inlet: 50 C (same flow-rate as under other conditions ()). () Estimated value in high speed cooling operation, with two 90 elbows on each hose.. - OTHER CONDITIONS Consult us. Operating limits: - Minimum water inlet temperature : 4 C. - Maximum water inlet temperature : 60 C. - Maximum operating pressure of the hydraulic circuit: 6 bar. - Minimum air recirculation temperature : 5 C. - Maximum air recirculation temperature : C.

- PHYSICAL CHARACTERISTICS Materials: - Painted metal frame. - Plastic body. - Copper/aluminium exchanger. - Copper piping. P L KPSW Overall L mm 900 dimensions H mm 680 P mm 90 H Weight kg.5 Overall L mm 0 packed H mm 8 dimensions P mm 96 Weight kg 4 - DESCRIPTION Model Copper/aluminium thermal exchanger Number of rows Frontal surface area m Water capacity Hydraulic connection litres KPSW 0.78 KPSW 0.78 KPSW 4 0.78 Electrical motor with internal thermal protection Power supply 0 V / + Earth / 50 Hz Number of speeds Capacitor µf Tangential fan Air filter in class HB polypropylene (UL94) - Washable Flexible connection tubes accessory Condensate drain pan expanded polystyrene, supplied with drainage hose End fitting OD mm Wire remote control version Infrared remote control version. 8.5 8 8 4

5 - ACCESSORIES 5. - FLEXIBLE TUBES for hydraulic connection Set of insulated metal flexible tubes (these tubes do not crush when bent). Code 70600060 70600059 Length (mm) 550 50 air handler side fe fe Connections installation side 5. - ACTIVE CARBON FILTER Code 970907. 5. - -WAY VALVE + BY-PASS Code 7060007. -. - KVS.6. - "On/Off" motor 0 VAC. - To be assembled outside the unit. Note: The valve is supplied without connection or tube. This valve kit can be mounted on all models and is obligatory for cold water use. If this valve is not installed, there is a risk of condensation forming on the machine when it is switched off by the thermostat. 5.4 - REMOTE CONTROLS (for the wire remote control version) Model KPSW 7050076 Manual remote control 705005 RCC 0 automatic remote control for -pipe units 705005 Change/over sensor with bracket for RCC (may be used as an air recirculation sensor) 7050054 Air temperature sensor in box for RCC Note: "On-Off" action on valve, 0 VAC (accessory) or action on ventilation. A - MANUAL REMOTE CONTROL Code 7050076. The operating mode is selected manually by a switch on the front of the control unit. Technology : electromechanic. Power supply : 0 Vac Set-point adjustment range: 8 / 0 C (possibility of mechanical limitation by jumpers on the knob) "On-Off" action Control differential : K Operating temperature : 0 / 50 C Relative humidity : < 95% Protection class : cl. II IP :0 Colour : White RAL 900 Operating switch with fan speed selection Temperature setting knob Heating / cooling selector switch 5

B - AUTOMATIC REMOTE CONTROL Type RCC 0 - code 705005. Selection of the operating mode is done automatically. For the -pipe units capable of heating and cooling operation, a change-over sensor must be connected (accessory, code 705005) to the installation on the water piping. This change-over sensor can be replaced by a potential-free contact (not supplied), the closing of which causes changeover to cooling mode. There is a possibility to connect a remote air temperature sensor, bare (accessory, code 705005) or box mounted (accessory, code 7050054). Permanent or slaved ventilation. Mode change is possible (Eco or Stand-by) by an external potential-free contact (not supplied). Technology : electronic. Power supply : 0 Vac Set-point adjustment range: 8 / 0 C (possibility of mechanical limitation by jumpers on the knob) "On-Off" action Heating differential : adjustable or 4 K Cooling differential : adjustable 0.5 or K Neutral zone (on RCC 0) : adjustable or 5 K Setpoint in "Eco" mode : 6 C in heating mode 8 C in cooling mode Setpoint in "Standby" : 8 C in heating mode Operating temperature : 0 / 50 C Relative humidity : < 95% Protection class : cl. II IP :0 Colour : White RAL 900 Heating on indicator light Ventilation on indicator light Cooling on indicator light Temperature setting knob Operating switch with fan speed selection C - TEMPERATURE SENSOR (BARE) Code 705005. For RCC type remote control. Use: - change over sensor (equipped with a tube retaining clip) for "-tube" appliances may operate in heating and cooling mode, - air recirculation sensor. Thermistance type CTN kω at 5 C. IP 65 - protection class: cl. II. D - BOX-MOUNTED AIR TEMPERATURE SENSOR Code 7050054. For RCC remote controls. Enables the control unit to be placed outside the room to be air conditioned. Thermistance type CTN kω at 5 C. The unit is mounted in a box similar to the remote control (IP 0 - protection class: cl. II - colour: white RAL 900). Due to our policy of continuous development, our products are liable to modification whitout notice. 6 R.D. 8 Reyrieux BP 060 Trévoux CEDEX France Phone 4 74 00 9 9 - Fax 4 74 00 4 000 R.C.S. Bourg-en-Bresse B 759 00 78