CE arking for Fire Resistant doors. The future EN 16034 Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab. AFITI-LICOF 1
Overview Pedestrian doorsets, industrial, commercial, garage doors and windows - Product standard, performance characteristics Fire resistance and/or smoke control characteristics European Harmonised Standard CE arking andates to CEN : /101; /126, /130, /137 (amendments) Intended use (s): In fire/smoke compartmentation; in other declared specific uses and/or other uses subject to specific requirements, in particular noise, energy, tightness and safety in use. 2 Agustín Garzón Cabrerizo -
Industrial Commercial Garage Pedestrian windows and doors Exteriors Interiors Fire resistance and/or smoke control CE arking for Fire Resistant doors. The future EN 16034 Overview. Related Standards Scope Standard EN 13241-1 Industrial, commercial and garage doors and gates Product standard Part 1: Products without fire resistance or smoke control characteristics EN 14351-1 Windows and doors Product standard, performance characteristics Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics pren 14351-2 Windows and doors - Product standard, performance characteristics Part 2: Internal pedestrian doorsets without resistance to fire and/or smoke leakage characteristics FprEN 16034 EN 16035 Pedestrian doorsets, industrial, commercial, garage doors and windows Product standard, performance characteristics Fire resistance and/or smoke control characteristics HPS - Hardware performance sheet EN 14600 EN 1634-1 ; EN 1634-2 ; EN 1634-1 EXAP: EN/prEN 15269-1 to 15269-11; EN 15269-20 3 Agustín Garzón Cabrerizo -
Completion of the revision Start of the final draft Completion of the final draft Completion of the formal vote Date of availability, Publication in the OJEU Planned start of the transition period Actual situation Latest issue Harmonised Overview. Draft Situation 2009 2010-2011 2012 2013 2014 Standard S O N D E F A J J A S O N D E F A J J A S O N D E F A J J A S O N D E F A J J A S O N D pren 16034 F.Draft may-10 X Creating of TC33 WG5 Earliest 2014 CEN Enquiries, comments & handling Draft Formal Vote or UAP Publishing Possible CE arking 4 Agustín Garzón Cabrerizo -
CPD Compliance. Chapters of the standard Table ZA.1.1. Essential characteristics Fire Resistance Smoke control Ability to release Durability of the ability to release Self-closing Self-closing durability Table ZA.2. Attestation of conformity Intended use System Fire/smoke compartmentation 1 Table ZA.3. Assignation of tasks for the evaluation of conformity NB Notified Body F anufacturer 5 Agustín Garzón Cabrerizo -
System of Attestation of Conformity. Requirements Para. 7.5. Factory Production Control [FPC] A FPC should be available with documented procedures, regular inspections and testing, control of equipment and raw materials. Everything should be documented and a responsible person designated. PURPOSE To ensure that the products commercialized meet the performance characteristics declared. Initial Type Testing [ITT] Paras 7.2., 7.3. y 7.4. The manufacturer must declare all the essential operating characteristics, which should undergo initial testing. Test samples should be representative of the standard product manufacturing. Tests should be performed / managed by the Notified Body. PURPOSE Determination of mandatory characteristics for products, by testing and / or calculations Para 7.6. Initial inspection of FPC PURPOSE To verify that the specifications of the standard are met. To check that the processes are carried out according to the documented procedures. Para. 7.7. Surveillance of FPC PURPOSE To verify the maintenance of the requirements established. - Frequency of realization: Not less than once a year. 6 Agustín Garzón Cabrerizo -
System of Attestation. Assignation of Tasks For the anufacturer Initial type testing Factory production control Testing of samples in the factory in accordance with a prescribed test plan For the Notified Body Initial type testing Factory production control. Initial inspection Factory production control. Regular inspections SUPPORTING DOCUENTATION Declaration of conformity from the anufacturer * Certificate of conformity of the product * F F F NB NB NB F NB * Once entered in force the CPR, this nomenclature will be changed in accordance with new legislative act. 7 Agustín Garzón Cabrerizo -
Requirements NOT related to fire resistance and /or smoke control Essential Characteristics Product Standard EN 13241-1. Industrial, commercial and garage doors and gates EN 14351-1. Windows and external pedestrian doorsets pren 14351-2. Windows and internal pedestrian doorsets Additional requirements for specific operating characteristics Operating characteristics Normative references Test Classification Ability to release For locked doors located on escape routes only. EN 179 EN 1125 pren13633 FprEN13637 EN 1935 Durability of the ability to release For locked doors located on escape routes only. EN 1191 (Pedestrian) EN 12046-2 (Operating forces) EN 12400 (non-self-closing) EN 14600 (self-closing) EN 12217 (operating forces) 8 Agustín Garzón Cabrerizo -
Essential Characteristics Requirements related to Fire Resistance and Smoke Control Operating Characteristics Fire Resistance Normative references Test Classification EN 14600 EN 1634-1 EN 13501-2 E, EI1, EI2, EW Smoke control Only for uses where there are limitations on the spread of smoke EN 14600 EN 1634-3 EN 13501-2 Sa, Sm Self-closing and durability of self-closing For self-closing doors only EN 14600 EN 1191 (Pedesrtrian) EN 12605 (Industrial) EN 14600 C0; C1; C2; C3; C4; C5 9 Agustín Garzón Cabrerizo -
Essential Characteristics. Application of Test Results The rules for considering of the field of application are those defining the variations on the product being tested, and that are possible to be applied without further testing to fire resistance and /or smoke control. Direct field of application The rules are defined in the standards EN 1634-1 y EN 1634-3. They are based on the test results. Extended field of application The rules are defined in the series of standards pren/en 15269. They are based on the consensual technical opinions, the experience on fire resistance tests and the interpolation of results. EXAP standard EN 15269-1. General requirements EN 15269-2. Hinged and pivoted steel doorsets EN 15269-3. Hinged and pivoted timber doorsets EN 15269-4. Glazed doorsets pren 15269-5. H.&p. metal framed glazed doorsets pren 15269-6. Timber sliding doorsets EXAP standard EN 15269-7. Steel sliding doorsets pren 15269-8. Timber folding doorsets pren 15269-9. Steel folding doorsets EN 15269-10. Steel rolling shutter assemblies pren 15269-11. Operable fabric curtains EN 15269-20. (smoke control) H.&p. steel, timber and metal framed glazed doorsets 10 Agustín Garzón Cabrerizo -
Essential Characteristics. Application of Test Results Extended field of application. Interchangeability of elements of building hardware HPS Hardware performance sheet. EN 16035 This is a summary of information proceeding from the test reports required to assess the interchangeability of a particular element of building hardware The HPS is a part of the technical documentation to be submitted to the Notified Body, when the rules of the extended field of application are desired to be used. A HPS may be performed by: anufacturer of buiding hardware or Door manufacturer or Notified Body In any case, it is the responsibility of the Notified Body to verify that the content is correct and up to date. 11 Agustín Garzón Cabrerizo -
Essential Characteristics. Cascading Tests What are the cascading tests? The cascading tests relate to the possibility that the companies have, being supplier of any component/s of a particular product to the assembler or manufacturer, - who then manufactures and puts on market the final product, - to be able to perform ITT s on certain product models already assembled and to cede the use of such tests to the assembler or end product manufacturer. This deals with a possibility in which the systems enterprise", "spectrum manufacturer" or companies suppliers of any of the components of the final product, hereinafter "Supplier", cedes the ITT to their customers, assemblers or end product manufacturers, hereinafter "anufacturer". S Requirements for using the results of cascading ITT Written contract between the Supplier who performed the ITT and the anufacturer, containing the authorization for such transfer. The Supplier should provide the anufacturer with all the technical documentation that supports the CE arking: Test report, Classification Report, EXAP Reports, assembly and/or manufacturing instructions; product specifications,... This documentation should be part of the anufacturer's FPC. This documentation should be preserved for 10 years (from the date of manufacture). The anufacturer is responsible for ensuring that his product possesses the same characteristics and/or benefits that the product subjected to the mentioned ITT s, and has been assembled in accordance with the Supplier's instructions. The anufacturer and his staff should receive training from the Supplier. 12 Agustín Garzón Cabrerizo -
ITT Initial Type Testing Essential Characteristics. Cascading Tests CE arking through anufacturer ITT ITT Cascading S ITT applicant NB Tests S Owner of reports ITT applicant Use of ITT from S NB Tests Agreement S Owner of reports ITT from S verification by FPC Factory Production Control 13 Agustín Garzón Cabrerizo -
CE arking. Labeling XXX Inc. Portugal Name or identifying mark and registered address of the producer 13 Last 2 digits of the year in which the marking is affixed 01246 CPD- 048966 Certificate of Conformity number EN 16034 Fire resistant door Series nº o unique nº Fire resistance [technical class] Smoke control [technical class] Self closing [technical class] Number of the European Standard Description of the product and intended use Identification number Information on regulated characteristics of the product CE conformity marking, consisting of the CE symbol given in Directive 93/68/EEC 01234 Identification number of the certification body 89/106/CE Reference to related Directive 14 Agustín Garzón Cabrerizo -
- Thank you for your attention - CE arking for Fire Resistant doors. The future EN 16034 Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab. AFITI-LICOF 15