CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Similar documents
EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

The New Generationn of Firedoors

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

Contents EN :2006+A2:2016 (E)

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Technical Bulletin CE marking: from 1st July 2013

CE marking of fire-resistant doors the right way!

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Your Key to achieving C.E Marking Compliance

1. Terms defined in the Construction Products Regulation (CPR)

Guidance Note No 19/1. CE Marking windows and doorsets

Construction Products Directive

F O C U S D O O R C L O S E R S

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Construction Products Directive

CEN/TC 207 N N Work programme May Document type: Other committee document. Date of document:

Guideline Construction Products Regulation (EU) 305/20122

Living with the Construction Products Directive - The Role of the Notified Bodies

Co-ordination of the Group of Notified Bodies for the Construction Products /Regulation 305/2011/EU

Centexbel. General certification regulations. Construction products

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Sýnishorn Glass in building - Insulating glass units - Part 5: Evaluation of conformity

Panic and Emergency Exit Devices

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Domestic Garage Doors

GNB-CPR Position Paper: Issuance of certificates under CPR

PRESS RELEASE

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

The New EU-Regulation on Construction Products

CE MARKING OF WOOD-BASED PANELS

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

Mechanically operated locks and locking plates

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Declaration of Conformity Declaration of Performance Notes

S I M P L Y C E INTRODUCTION TO CE NORMS AND STANDARDS FOR DOORS AND GATES TWO THOUSAND EIGHTEEN

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

Electromagnetic Locking Devices Performance Requirements

Implementing the Construction Products Regulation (EU) 305/2011

ECCS TC9 Manufacturing and Erection Standards. Guide to the CE Marking of Structural Steelwork

CPR, CE-marking of construction products 1

Controlled Door Closing Devices

The Danish Energy Authority to carry out inspections in June and July 2012

Update on European Standardization Work

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Standards and Standardisation. An Overview

This is a preview - click here to buy the full publication

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

QAiST WP2 and 6 A status report

ETICS & HARMONIZATION The challenges

Construction Products Regulation (CPR) and BS 6701

CE marking: implications for timber products

Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Assessment Report Construction Product Regulation* * CPR - REGULATION (EU) No 305/2011

Loss Prevention Standard

CONSTRUCTION PRODUCTS REGULATION 2011 DECLARATION OF PERFORMANCE

Electromagnetic Locking Devices

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

This is a preview - click here to buy the full publication

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Mandate M/118 WASTE WATER ENGINEERING PRODUCTS

BUSINESS PLAN CEN/TC 250 STRUCTURAL EUROCODES EXECUTIVE SUMMARY

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

Confused by standards Standards for social alarms

TECHNICAL SPECIFICATION

Georgios Katsarakis European Commission

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

YOUR GUIDE TO UNDERSTANDING CPR

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Main changes to draft SR 21:2013 Hardcore material for use under concrete floors

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

Draft minutes of the meeting of

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

Report on the activities of the ATEX consultant. Xavier Lefebvre. Contract : CENELEC/NA Consultant/2013-1

BUSINESS PLAN CEN/TC 58 SAFETY AND CONTROL DEVICES FOR BURNERS AND APPLIANCES BURNING GASEOUS OR LIQUID FUELS EXECUTIVE SUMMARY

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

TECHNICAL SPECIFICATION

The Danish Energy Agency will carry out inspections in June 2013

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

CERTIFICATE. Conformity of the Factory Production Control CPR TÜVRh

BUSINESS PLAN CEN/TC 23 TRANSPORTABLE GAS CYLINDERS

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CEN System - Delegated Decisions Dispatch 14:2017

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

INTERNATIONAL STANDARD

CE marking of noise barriers and foundations

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

NFPA 80 Overview January 21, 2016

This is a preview - click here to buy the full publication

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Solar Keymark in Europe. DI (FH) Gundula Tschernigg AIT Austrian Institute of Technology

This is a preview - click here to buy the full publication

BUSINESS PLAN CEN/TC 149 POWER-OPERATED WAREHOUSE EQUIPMENT EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 164 WATER SUPPLY EXECUTIVE SUMMARY

Transcription:

CE arking for Fire Resistant doors. The future EN 16034 Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab. AFITI-LICOF 1

Overview Pedestrian doorsets, industrial, commercial, garage doors and windows - Product standard, performance characteristics Fire resistance and/or smoke control characteristics European Harmonised Standard CE arking andates to CEN : /101; /126, /130, /137 (amendments) Intended use (s): In fire/smoke compartmentation; in other declared specific uses and/or other uses subject to specific requirements, in particular noise, energy, tightness and safety in use. 2 Agustín Garzón Cabrerizo -

Industrial Commercial Garage Pedestrian windows and doors Exteriors Interiors Fire resistance and/or smoke control CE arking for Fire Resistant doors. The future EN 16034 Overview. Related Standards Scope Standard EN 13241-1 Industrial, commercial and garage doors and gates Product standard Part 1: Products without fire resistance or smoke control characteristics EN 14351-1 Windows and doors Product standard, performance characteristics Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics pren 14351-2 Windows and doors - Product standard, performance characteristics Part 2: Internal pedestrian doorsets without resistance to fire and/or smoke leakage characteristics FprEN 16034 EN 16035 Pedestrian doorsets, industrial, commercial, garage doors and windows Product standard, performance characteristics Fire resistance and/or smoke control characteristics HPS - Hardware performance sheet EN 14600 EN 1634-1 ; EN 1634-2 ; EN 1634-1 EXAP: EN/prEN 15269-1 to 15269-11; EN 15269-20 3 Agustín Garzón Cabrerizo -

Completion of the revision Start of the final draft Completion of the final draft Completion of the formal vote Date of availability, Publication in the OJEU Planned start of the transition period Actual situation Latest issue Harmonised Overview. Draft Situation 2009 2010-2011 2012 2013 2014 Standard S O N D E F A J J A S O N D E F A J J A S O N D E F A J J A S O N D E F A J J A S O N D pren 16034 F.Draft may-10 X Creating of TC33 WG5 Earliest 2014 CEN Enquiries, comments & handling Draft Formal Vote or UAP Publishing Possible CE arking 4 Agustín Garzón Cabrerizo -

CPD Compliance. Chapters of the standard Table ZA.1.1. Essential characteristics Fire Resistance Smoke control Ability to release Durability of the ability to release Self-closing Self-closing durability Table ZA.2. Attestation of conformity Intended use System Fire/smoke compartmentation 1 Table ZA.3. Assignation of tasks for the evaluation of conformity NB Notified Body F anufacturer 5 Agustín Garzón Cabrerizo -

System of Attestation of Conformity. Requirements Para. 7.5. Factory Production Control [FPC] A FPC should be available with documented procedures, regular inspections and testing, control of equipment and raw materials. Everything should be documented and a responsible person designated. PURPOSE To ensure that the products commercialized meet the performance characteristics declared. Initial Type Testing [ITT] Paras 7.2., 7.3. y 7.4. The manufacturer must declare all the essential operating characteristics, which should undergo initial testing. Test samples should be representative of the standard product manufacturing. Tests should be performed / managed by the Notified Body. PURPOSE Determination of mandatory characteristics for products, by testing and / or calculations Para 7.6. Initial inspection of FPC PURPOSE To verify that the specifications of the standard are met. To check that the processes are carried out according to the documented procedures. Para. 7.7. Surveillance of FPC PURPOSE To verify the maintenance of the requirements established. - Frequency of realization: Not less than once a year. 6 Agustín Garzón Cabrerizo -

System of Attestation. Assignation of Tasks For the anufacturer Initial type testing Factory production control Testing of samples in the factory in accordance with a prescribed test plan For the Notified Body Initial type testing Factory production control. Initial inspection Factory production control. Regular inspections SUPPORTING DOCUENTATION Declaration of conformity from the anufacturer * Certificate of conformity of the product * F F F NB NB NB F NB * Once entered in force the CPR, this nomenclature will be changed in accordance with new legislative act. 7 Agustín Garzón Cabrerizo -

Requirements NOT related to fire resistance and /or smoke control Essential Characteristics Product Standard EN 13241-1. Industrial, commercial and garage doors and gates EN 14351-1. Windows and external pedestrian doorsets pren 14351-2. Windows and internal pedestrian doorsets Additional requirements for specific operating characteristics Operating characteristics Normative references Test Classification Ability to release For locked doors located on escape routes only. EN 179 EN 1125 pren13633 FprEN13637 EN 1935 Durability of the ability to release For locked doors located on escape routes only. EN 1191 (Pedestrian) EN 12046-2 (Operating forces) EN 12400 (non-self-closing) EN 14600 (self-closing) EN 12217 (operating forces) 8 Agustín Garzón Cabrerizo -

Essential Characteristics Requirements related to Fire Resistance and Smoke Control Operating Characteristics Fire Resistance Normative references Test Classification EN 14600 EN 1634-1 EN 13501-2 E, EI1, EI2, EW Smoke control Only for uses where there are limitations on the spread of smoke EN 14600 EN 1634-3 EN 13501-2 Sa, Sm Self-closing and durability of self-closing For self-closing doors only EN 14600 EN 1191 (Pedesrtrian) EN 12605 (Industrial) EN 14600 C0; C1; C2; C3; C4; C5 9 Agustín Garzón Cabrerizo -

Essential Characteristics. Application of Test Results The rules for considering of the field of application are those defining the variations on the product being tested, and that are possible to be applied without further testing to fire resistance and /or smoke control. Direct field of application The rules are defined in the standards EN 1634-1 y EN 1634-3. They are based on the test results. Extended field of application The rules are defined in the series of standards pren/en 15269. They are based on the consensual technical opinions, the experience on fire resistance tests and the interpolation of results. EXAP standard EN 15269-1. General requirements EN 15269-2. Hinged and pivoted steel doorsets EN 15269-3. Hinged and pivoted timber doorsets EN 15269-4. Glazed doorsets pren 15269-5. H.&p. metal framed glazed doorsets pren 15269-6. Timber sliding doorsets EXAP standard EN 15269-7. Steel sliding doorsets pren 15269-8. Timber folding doorsets pren 15269-9. Steel folding doorsets EN 15269-10. Steel rolling shutter assemblies pren 15269-11. Operable fabric curtains EN 15269-20. (smoke control) H.&p. steel, timber and metal framed glazed doorsets 10 Agustín Garzón Cabrerizo -

Essential Characteristics. Application of Test Results Extended field of application. Interchangeability of elements of building hardware HPS Hardware performance sheet. EN 16035 This is a summary of information proceeding from the test reports required to assess the interchangeability of a particular element of building hardware The HPS is a part of the technical documentation to be submitted to the Notified Body, when the rules of the extended field of application are desired to be used. A HPS may be performed by: anufacturer of buiding hardware or Door manufacturer or Notified Body In any case, it is the responsibility of the Notified Body to verify that the content is correct and up to date. 11 Agustín Garzón Cabrerizo -

Essential Characteristics. Cascading Tests What are the cascading tests? The cascading tests relate to the possibility that the companies have, being supplier of any component/s of a particular product to the assembler or manufacturer, - who then manufactures and puts on market the final product, - to be able to perform ITT s on certain product models already assembled and to cede the use of such tests to the assembler or end product manufacturer. This deals with a possibility in which the systems enterprise", "spectrum manufacturer" or companies suppliers of any of the components of the final product, hereinafter "Supplier", cedes the ITT to their customers, assemblers or end product manufacturers, hereinafter "anufacturer". S Requirements for using the results of cascading ITT Written contract between the Supplier who performed the ITT and the anufacturer, containing the authorization for such transfer. The Supplier should provide the anufacturer with all the technical documentation that supports the CE arking: Test report, Classification Report, EXAP Reports, assembly and/or manufacturing instructions; product specifications,... This documentation should be part of the anufacturer's FPC. This documentation should be preserved for 10 years (from the date of manufacture). The anufacturer is responsible for ensuring that his product possesses the same characteristics and/or benefits that the product subjected to the mentioned ITT s, and has been assembled in accordance with the Supplier's instructions. The anufacturer and his staff should receive training from the Supplier. 12 Agustín Garzón Cabrerizo -

ITT Initial Type Testing Essential Characteristics. Cascading Tests CE arking through anufacturer ITT ITT Cascading S ITT applicant NB Tests S Owner of reports ITT applicant Use of ITT from S NB Tests Agreement S Owner of reports ITT from S verification by FPC Factory Production Control 13 Agustín Garzón Cabrerizo -

CE arking. Labeling XXX Inc. Portugal Name or identifying mark and registered address of the producer 13 Last 2 digits of the year in which the marking is affixed 01246 CPD- 048966 Certificate of Conformity number EN 16034 Fire resistant door Series nº o unique nº Fire resistance [technical class] Smoke control [technical class] Self closing [technical class] Number of the European Standard Description of the product and intended use Identification number Information on regulated characteristics of the product CE conformity marking, consisting of the CE symbol given in Directive 93/68/EEC 01234 Identification number of the certification body 89/106/CE Reference to related Directive 14 Agustín Garzón Cabrerizo -

- Thank you for your attention - CE arking for Fire Resistant doors. The future EN 16034 Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab. AFITI-LICOF 15