Wireless Wall-Mount Sensor

Similar documents
Wireless Wall-Mount Sensor

Wireless Wall-Mount Sensor

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

ViveTM Basic Packages

Application Note #407 Revision F March 2019

Maestro Occupancy Sensor C L Dimmer

Vive PowPak Fixture Controls

Infrared Ceiling Mount Sensor

Maestro Occupancy Sensing Switch

Maestro Occupancy Sensing Switch

Maestro Occupancy sensing switch

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

Infrared Wall Mount Occupancy Sensor

Maestro Occupancy sensing switch

Infrared Ceiling Mount Sensor

Maestro 0 10 V Dimmer Sensor

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

Quick Install Energy Solutions

Maestro Dual-Circuit Occupancy Sensing Switch

Dimmer/Switch with Occupancy and Vacancy Sensor

VESICA LINEAR SUSPENDED VES L

Vive wireless hub. BACnet Integration. Demand Response

Wireless Plug Load Control

Maestro Occupancy sensing switch

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

ANSI/ASHRAE/IES

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Document # R01

Meeting RF Performance Criteria...7 Background...7 Expectations...7 End-of-Line Testing...7 Fixture Control Self-Test...7 Basic Functionality...

PIR Occupancy & Motion Sensor

Quick Install Energy Solutions Featuring Energi TriPak

ANSI/ASHRAE/IES

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Low-Voltage Occupancy Sensors

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

1126 Series Ceiling Mount PIR Motion Detector

Code Compliance Commercial Application Guide

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Quick Install Energy Solutions Featuring Energi TriPak

TECHNOLOGY PACIFIC SECURITY. Wireless Internal Siren. 2-Way Wireless Outdoor Siren. Alexor 2-Way Wireless Panel

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

ENERGY EFFICIENCY EXPERTS

EasyAir office sensor advanced grouping SNS200

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

Indoor Controls. SpaceWise SWZG2. Wireless technology

Installation Instructions

600 Watt Dimmer Install Guide

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Pet Immune SAW PIR Motion Sensor

MALAVIYA NATIONAL INSTITUTE OF TECHNOLOGY JAIPUR. No. F5(1587)ST/MNIT/Estate/2016 Phone : ,

RA2 Select. Whole home lighting control made simple. Lutron.com/ra2select. Lutron Electronics Co., Inc Suter Road Coopersburg, PA

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

Maestro Wireless dimmers, switches and sensors

1125 PIR Motion Detector

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Technical Application Guide

Wireless Occupancy Sensor:

LED HIGH BAY LINEAR ECO SERIES

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

UP 258E11 OPTISENS OFFICE

Limitless Wireless Din-Rail Receiver. WDRR Series. Datasheet

EcoSystem H-Series Ballasts

myroomtm Operations and Maintenance MANUAL

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

Application Note #451 Revision B June 2012

IP65 High Bay Dual Sense Sensor

HIGH POWER LED RETROFIT MODULE

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

Motion Detector User Guide

design guide for wireless l i g h t i n g c o n t r o l

Ivalo Lumaris LED Linear Lighting

2800 Series Control Units

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

IP65 High Bay Dual Sense Sensor

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

0ACDT2000MV Ultasonic/Infared Occ Sensor

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Ceiling PIR HS presence detector. Product Guide. Overview. Features

Occupancy and Vacancy Sensors

Application Note #603 Revision A June 2016 Lighting Control for Noise-Sensitive Applications

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Ever evolving energy code requirements and the large demand for energy

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Transcription:

Wireless Wall-Mount Sensor 369-481a 1 01.17.12 LutronR wall-mounted occupancy and vacancy sensors are wireless battery-powered passive infrared (PIR) sensors that automatically control lights via RF communication to compatible dimming or switching devices. These sensors detect the heat from people moving within an area to determine when the space is occupied. The sensors then wirelessly transmit the appropriate commands to the associated dimming or switching devices to turn the lights on or off automatically. They combine both convenience and exceptional energy savings along with ease of installation. Features Wireless occupancy sensor has 2 settings available: Auto-On/Auto-Off, and Manual-On/Auto-Off Vacancy model meets CA Title 24 requirements Passive infrared motion detection with exclusive LutronR XCTT Technology for fine motion detection 180 field of view model: Minor motion = 150 2 (139.4 m 2 ) Major motion = 300 2 (278.7 m 2 ) 90 field of view model: Minor motion = 1225 ft 2 (113.8 m 2 ) Major motion = 250 2 (232.3 m 2 ) Hallway model with long, narrow field of view: Major motion = coverage of up to 15 (45.7 m) Simple and intuitive adjustments available for Timeout, Activity, and Auto-On settings Accessible test buttons make setup easy Lens illuminates during test mode to verify ideal locations Multiple sensors can be added for extended coverage refer to product specification submittal of receiving device to determine system limits 10-year battery life design RoHS compliant Compatible RF Devices For use with LutronR products only Communicates to various wireless LutronR Clear ConnectT systems* * Contact Lutron Customer Service at www.lutron.com for frequency/channel code compatibility with your particular geographic region, and for integrating with other LutronR lighting and shading products. Models Available LRFX-XXLB-P-WH Example: LRF2-VHLB-P-WH 434 MHz White Hallway Vacancy Sensor Frequency/Channel Codes 2 = 431.0 437.0 MHz (US, Canada, Mexico, Brazil) 3 = 868.125 869.850 MHz (Europe and UAE) 4 = 868.125 868.475 MHz (China and Singapore) 5 = 865.5 866.5 MHz (India) 6 = 312.3 314.8 MHz (Japan) 7 = 433.05 434.79 MHz (Hong Kong) Sensor Type O = Occupancy (Auto-On/Auto-Off) V = Vacancy (Manual-On/Auto-Off) Coverage Type H = Hallway K = 90 Corner-Mount W = 180 Wall-Mount Coverage Type Sensor Type Frequency / Channel Code

Specifications Regulatory Lutron Quality Systems Registered to ISO 9001:2008 Standards LRF2- culus Listed FCC certified IC certified COFETEL certified ANATEL certified [expected Q1 2012] SUTEL certified Meets CA (U.S.A.) Energy Commission Title 24 requirements LRF3- CE Marked (European Union) [expected Q2 2012] TRA Type Approved (United Arab Emirates) [expected Q1 2012] LRF4- SRRC Type Approved (Mainland China) [expected Q2 2012] ida Registered (Singapore) [expected Q2 2012] LRF5- WPC Type Approved (India) [expected Q2 2012] LRF6-007YUUL0689 [expected Q2 2012] LRF7- FCC certified [expected Q2 2012] Power/Performance Operating voltage: 3 V - Operating current: 14 μa nominal Requires one CR 123 lithium battery 10-year battery life design Non-volatile memory (saved changes are stored during power loss) Environment Temperature: 32 F to 104 F (0 C to 40 C) For indoor use only 369-481a 2 01.17.12 RF Range LRF2, LRF3, LRF4, LRF5, LRF7 Distance between local load controls and sensor should not exceed 6 (18 m) line of sight or 3 (9 m) through walls. LRF6 Distance between local load controls and sensor should not exceed 4 (12.2 m) line of sight or 23 ft (7 m) through walls. Sensor Coverage Test Dedicated test button Lens illuminates orange in response to motion during test mode Wireless Communication Test Dedicated test button Turn associated loads on and off Timeout Options 1 minute * 5 minutes 15 minutes default setting 30 minutes Auto-On Options (Occupancy Versions Only) Enabled Sensor turns lights ON and OFF automatically default setting. Disabled ** Lights must be turned ON manually from dimming or switching device. Sensor turns lights OFF automatically. Sensitivity Options Low Activity ( ) default setting Medium Activity ( ) High Activity ( ) * Intended for use in high-activity, briefly occupied areas only ** There is a 15-second grace period that begins when the lights are automatically turned off, during which the lights will automatically turn back on in response to motion. This grace period is provided as a safety and convenience feature in the event the lights turn off while the room is still occupied, so that the user does not need to manually turn the lights back on. After 15 seconds, the grace period expires and the lights must be manually turned on.

Dimensions 369-481a 3 01.17.12 4.35 in (110 mm) 1.8 in (46 mm) 1.35 in (34 mm)

Coverage Diagrams 180 Wall-Mount Sensors (Models: LRFX-OWLB-P-WH and LRFX-VWLB-P-WH) Top View 369-481a 4 01.17.12 25 ft (7.6 m) 2 (6.1 m) 1 (3.0 m) 1 (3.0 m) 2 (6.1 m) 25 ft (7.6 m) Minor Motion Coverage Area 150 2 (139.4 m 2 ) Major Motion Coverage Area 300 2 (278.7 m 2 ) Side View 7 ft (2.1 m) 1 (3.0 m) 2 (6.1 m) 3 (9.1 m) 4 (12.2 m) 5 (15.2 m) 6 (18.3 m) 1 (3.0 m) 2 (6.1 m) 3 (9.1 m) 4 (12.2 m) 5 (15.2 m) 6 (18.3 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).

Coverage Diagrams 90 Corner-Mount Sensors (Models: LRFX-OKLB-P-WH and LRFX-VKLB-P-WH) Top View 369-481a 5 01.17.12 5 (15.2 m) 35 ft (10.7 m) Minor Motion Coverage Area 1225 ft 2 (113.8 m 2 ) Major Motion Coverage Area 250 2 (232.3 m 2 ) Side View 7 ft (2.1 m) 1 (3.3 m) 2 (5.9 m) 3 (9.1 m) 4 (12.2 m) 56 ft (16.9 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).

Coverage Diagrams Hallway Sensors (Models: LRFX-OHLB-P-WH and LRFX-VHLB-P-WH) 369-481a 6 01.17.12 Maximum Recommended Hallway Length Width of Hall Length of Hall 6 ft (1.0 m) or less 5 (15.2 m) 8 ft (2.4 m) 10 (30.5 m) 1 (3.0 m) or more 15 (45.7 m) Top View 1 (3.0 m) 5 ft (1.5 m) 5 ft (1.5 m) 1 (3.0 m) 25 ft (7.6 m) 5 (15.2 m) 75 ft (22.9 m) 10 (30.5 m) 125 ft (38.1 m) 15 (45.7 m) Side View 7 ft (2.1 m) 25 ft (7.6 m) 5 (15.2 m) 75 ft (22.9 m) 10 (30.5 m) 125 ft (38.1 m) 15 (45.7 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m) and centered within hallway. Designed to mount at the end of a hallway with a clear view down the length of a hall. Detection at longer distances is best when motion occurs at right angles to the sensor. Multiple sensors can be used to extend coverage.

Installation Overview 369-481a 7 01.17.12 Sensor Placement The mounting height of the sensor should be between 6 ft and 8 ft (1.6 m and 2.4 m) For smaller rooms less than 12 ft x 12 ft (3.7 m x 3.7 m), detection may be improved by mounting the sensor at 6 ft (1.8 m) from the floor. The ability to detect motion requires that the sensor have line-of-sight of all room occupants. The sensor must have an unobstructed view of the room. DO NOT mount behind or near tall cabinets, shelves, hanging fixtures, etc. The sensor cannot detect occupants through glass objects such as patio or shower doors. Hot objects and moving air currents can affect the performance of the sensor. To ensure proper operation, the sensor should be mounted at least 4 ft (1.2 m) away from light bulbs and HVAC vents. The performance of the sensor depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the sensor s ability to detect occupants. LRF2, LRF3, LRF4, LRF5, LRF7: Distance between local load controls and sensor should not exceed 6 (18 m) line of sight or 3 (9 m) through walls. LRF6: Distance between local load controls and sensor should not exceed 4 (12.2 m) line of sight or 23 ft (7 m) through walls.

Mounting 180 and hallway sensors mount directly to wall with mounting bracket (included). See figure below. 90 sensors mount directly in corner or on wall offset away from corner with mounting bracket (included). See figure below. 369-481a 8 01.17.12 Temporary mounting is recommended to test sensor coverage and wireless communication before permanently installing the sensor. Temporary mounting: A 3MT CommandT adhesive strip is provided for temporarily mounting and testing the sensor. This strip is designed for easy, damage-free removal and is not reusable. Permanent mounting: Mounting bracket, screws and anchors are provided to mount sensor. 180 Wall-Mount Sensor & Hallway Sensor 90 Corner-Mount Sensor 3M and Command are trademarks of 3M Company.