Wireless Wall-Mount Sensor

Similar documents
Wireless Wall-Mount Sensor

Wireless Wall-Mount Sensor

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

ViveTM Basic Packages

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

Application Note #407 Revision F March 2019

Maestro Occupancy Sensor C L Dimmer

Maestro 0 10 V Dimmer Sensor

Maestro Occupancy Sensing Switch

Quick Install Energy Solutions

Infrared Wall Mount Occupancy Sensor

Maestro Occupancy Sensing Switch

Infrared Ceiling Mount Sensor

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Vive wireless hub. BACnet Integration. Demand Response

Dimmer/Switch with Occupancy and Vacancy Sensor

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

VESICA LINEAR SUSPENDED VES L

Infrared Ceiling Mount Sensor

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

ANSI/ASHRAE/IES

Maestro Wireless dimmers, switches and sensors

Maestro Dual-Circuit Occupancy Sensing Switch

Vive PowPak Fixture Controls

ANSI/ASHRAE/IES

Maestro Occupancy sensing switch

Maestro Occupancy sensing switch

Code Compliance Commercial Application Guide

Wireless Plug Load Control

Quick Install Energy Solutions Featuring Energi TriPak

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Maestro Occupancy sensing switch

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

RA2 Select. Whole home lighting control made simple. Lutron.com/ra2select. Lutron Electronics Co., Inc Suter Road Coopersburg, PA

PIR Occupancy & Motion Sensor

Wireless Occupancy Sensor, Ceiling Mount (WOS2-CM)

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Installation Instructions

Wireless Occupancy Sensor, Wall Mount with Photosensor (WOS2-WM)

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

1126 Series Ceiling Mount PIR Motion Detector

ENERGY EFFICIENCY EXPERTS

Ivalo Lumaris LED Linear Lighting

Welcome. Sensor. 1 (844) LIGHTCLOUD Custom manufactured in China RAB Lighting, Inc 170 Ludlow Avenue Northvale, NJ 07647

Ivalo Lumaris. LED Linear Lighting. High quality, even lines of illumination and guaranteed LED compatibility with 1% Lutron dimming IVALO COLLECTION

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

600 Watt Dimmer Install Guide

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Technical Application Guide

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

GRAFIK RA 2. Convenient, wireless light and blind control Integrates with leading smart home brands

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

ADDENDUM NO. 2 COOK LIBRARY BATHROOM RENOVATIONS PROJECT NUMBER TU-1874-SBR

MALAVIYA NATIONAL INSTITUTE OF TECHNOLOGY JAIPUR. No. F5(1587)ST/MNIT/Estate/2016 Phone : ,

EasyAir office sensor advanced grouping SNS200

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Pet Immune SAW PIR Motion Sensor

Ever evolving energy code requirements and the large demand for energy

Light control solutions

Wireless High Bay Sensor (WHS100) Installation Instructions

EasyAir SNH200. Sensors. Datasheet. EasyAir SNH200

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

Quick Install Energy Solutions Featuring Energi TriPak

RadioRA 2 PRELIMINARY COPY 68 F 70 F. Wall-mounted seetemp display for temperature control Coming soon!

lighting control Flexible control every step of the way Simple, scalable, wireless DESIGN INSTALL MAINTAIN

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

Ceiling PIR HS presence detector. Product Guide. Overview. Features

IP65 High Bay Dual Sense Sensor

Hi-lume 3D Overview. Fluorescent Dimming Ballasts

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

HIGH POWER LED RETROFIT MODULE

LED HIGH BAY LINEAR ECO SERIES

CPVan Home Alarm Starter Kit

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Indoor Controls. SpaceWise SWZG2. Wireless technology

EcoSystem H-Series Ballasts

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

IP65 High Bay Dual Sense Sensor

1125 PIR Motion Detector

Wireless Indoor Lighting Control System

Low-Voltage Occupancy Sensors

UP 258E11 OPTISENS OFFICE

Mini Product Guide.

LPCMPIRM65 & LPCMPIRDSI65

design guide for wireless l i g h t i n g c o n t r o l

Product Specifications Dialog Room Controller* (*patent pending)

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

Ivalo Lumaris LED Linear Lighting

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Transcription:

Wireless Wall-Mount Sensor 369-268 1 06.29.10 Lutron wall-mounted occupancy and vacancy sensors are wireless battery-powered passive infrared (PIR) sensors that automatically control lights via RF communication to compatible dimming or switching devices. These sensors detect the heat from people moving within an area to determine when the space is occupied. The sensors then wirelessly transmit the appropriate commands to the associated dimming or switching devices to turn the lights on or off automatically. They combine both convenience and exceptional energy savings along with ease of installation. Features Wireless occupancy sensor has 2 settings available: Auto-On/Auto-Off, and Manual-On/Auto-Off Vacancy model available to meet CA Title 24 requirements 10-year battery life design Passive infrared motion detection with exclusive Lutron XCTTM Technology 180 field of view: Minor motion = 1500 ft 2 (139.4 m 2 ) Major motion = 3000 ft 2 (278.7 m 2 ) 90 field of view: Minor motion = 1225 ft 2 (113.8 m 2 ) Major motion = 2500 ft 2 (232.3 m 2 ) Hallway version with long, narrow field of view: Major motion = coverage of up to 150 ft (45.7 m) RoHS compliant Simple and intuitive adjustments available for Timeout, Activity, and Auto-On settings Accessible test buttons make setup easy Lens illuminates during test mode to verify ideal locations Up to 3 sensors can be added to each RF dimming or switching device for extended coverage Each sensor may be added to up to 10 compatible RF dimming and switching devices for spaces with multiple zones of lighting The sensor should be mounted within 60 ft (18.3 m) line of sight or 30 ft (9.1 m) through walls, of the associated dimming and switching receiving devices Compatible RF Devices: Communicates to the following wireless Lutron systems: Maestro Wireless (MRF2) GRAFIK Eye QS Wireless Models Available: LRF2-OWLB-P-WH 434 MHz 180 Wall-Mount Occupancy/Vacancy Sensor LRF2-VWLB-P-WH 434 MHz 180 Wall-Mount Vacancy Sensor LRF2-OKLB-P-WH 434 MHz 90 Corner-Mount Occupancy/Vacancy Sensor LRF2-VKLB-P-WH 434 MHz 90 Corner-Mount Vacancy Sensor LRF2-OHLB-P-WH 434 MHz Hallway Occupancy/Vacancy Sensor LRF2-VHLB-P-WH 434 MHz Hallway Vacancy Sensor

Specifications Standards FCC IC Meets CA Title 24 requirements COFETEL Environment Temperature: 32 F - 104 F (0 C - 40 C) For indoor use only Power Operating voltage: 3 V Operating current: 14 μa nominal Requires one CR 123 lithium battery 10-year battery life design Non-volatile memory (saved changes are stored during power loss) Sensor Coverage Test Dedicated test button Lens illuminates orange in response to motion during test mode and is visible from 150 ft (45.7 m) Timeout Options 1 minute 5 minutes 15 minutes * 30 minutes 369-268 2 06.29.10 Auto-On Options (Occupancy Version Only) "Enabled" * - Sensor turns lights ON and OFF automatically. "Disabled" - Lights must be turned ON manually from dimming or switching device. Sensor turns lights OFF automatically. Sensitivity Options Low Activity* ( ) Medium Activity ( ) High Activity ( ) *-Default Settings Wireless Communication Test Dedicated test buttons Turn loads on and off Dimensions 4.35 in (110 mm) 1.8 in (46 mm) 1.35 in (34 mm)

Coverage Diagrams 180 Wall-Mount Sensors (Models: LRF2-OWLB-P-WH and LRF2-VWLB-P-WH) Top View 369-268 3 06.29.10 Minor Motion 1500 ft 2 (139.4 m 2 ) Major Motion 3000 ft 2 (278.7 m 2 ) 7 ft* (2.1 m) Side View 30 ft (9.1 m) 40 ft (12.2 m) 45 ft (13.7 m) 55 ft (16.8 m) 60 ft (18.3 m) 30 ft (9.1 m) 40 ft (12.2 m) 45 ft (13.7 m) 55 ft (16.8 m) 60 ft (18.3 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).

Coverage Diagrams 90 Corner-Mount Sensors (Models: LRF2-OKLB-P-WH and LRF2-VKLB-P-WH) 369-268 4 06.29.10 Top View Minor Motion 1225 ft 2 (113.8 m 2 ) Major Motion 2500 ft 2 (232.3 m 2 ) 7 ft* (2.1 m) Side View 30 ft (9.1 m) 40 ft (12.2 m) 45 ft (13.7 m) 55 ft (16.8 m) 60 ft (18.3 m) 65 ft (19.8 m) 70 ft (21.3 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m).

Coverage Diagrams Hallway Sensors (Models: LRF2-OHLB-P-WH and LRF2-VHLB-P-WH) 369-268 5 06.29.10 Maximum Recommended Hallway Length Width of Hall Length of Hall 6 ft (1.6 m) or less 8 ft (2.4 m) 100 ft (30.5 m) or more 150 ft (45.7 m) Top View 0 ft (0 m) 25 ft (7.6 m) 50 ft (15.2 m) 75 ft (22.9 m) 100 ft (30.5 m) 125 ft (38.1 m) 150 ft (45.7 m) 7 ft (2.1 m)* Side View 0 ft (0 m) 25 ft (7.6 m) 50 ft (15.2 m) 75 ft (22.9 m) 100 ft (30.5 m) 125 ft (38.1 m) * Sensor mounting shown at 7 ft (2.1 m). Mounting height should be between 6 and 8 ft (1.6 and 2.4 m) and centered within hallway. 150 ft (45.7 m) Designed for mounting at end of hallway with view down length of hall. Detection at longer distances is best for motion occurring at right angles to the sensor. Up to three sensors can be used for additional coverage.

Installation Overview 369-268 6 06.29.10 Sensor Placement The sensor s mounting height should be between 6 and 8 ft (1.6 and 2.4 m) The sensor s ability to detect motion requires line-of-sight of room occupants. The sensor must have an unobstructed view of the room. DO NOT mount behind or near tall cabinets, shelves, hanging fixtures, etc. The sensor cannot see through glass objects such as patio or shower doors. Hot objects and moving air currents can affect the sensor s performance. To ensure proper operation, the sensor should be mounted at least 4 ft (1.2 m) away from light bulbs and HVAC vents. The sensor s performance depends on a temperature differential between the ambient room temperature and that of room occupants. Warmer rooms may reduce the sensor s ability to detect occupants. The sensor should be mounted within 60 ft (18.3 m) line of sight or 30 ft (9.1 m) through walls, of the associated dimming and switching receiving devices. Set Up Sensor with Receiving Device GRAFIK Eye QS Wireless Press and hold Lights On and Lights Off buttons on sensor simultaneously for 3 seconds to enter set-up Press and hold on/off button on receiving device for 3-6 seconds Load will flash 3 times upon successful association Press and hold Lights On and Lights Off buttons simultaneously for 3 seconds to exit set-up Maestro Wireless Press and hold on/off button on receiving device for 6 seconds Press and hold Lights Off button on sensor for 6 seconds Load will flash 3 times upon successful association Advanced Set-Up (Adjusting Timeout, Activity and Auto-On) Timeout Activity Auto-On Check Settings: Press and release desired button; LED indicates current setting 30 min 15 min 5 min Enabled Disabled Change Settings: Press and hold desired button until LED flashes Press button again to select setting Press and hold button until LED turns on solid to save setting Change Settings (1-minute timeout): Press and hold timeout button (~10 sec) until all 3 LEDs flash Press and hold button until all 3 LEDs turn on solid to save 1-minute timeout setting Default Settings Timeout 15 Minutes Activity Low Activity ( ) Auto-On Enabled

Mounting 180 and hallway sensors mount directly to wall with mounting bracket (included). See figure below. 369-268 7 06.29.10 90 sensors mount directly in corner or on wall offset away from corner with mounting bracket (included). See figure below. Temporary mounting is recommended to test sensor coverage and wireless communication before permanently installing the sensor. Temporary mounting: 3MTM CommandTM adhesive strips are provided for temporarily mounting and testing the sensor. These strips are designed for easy, damage-free removal and are not reusable. Permanent mounting: Mounting bracket, screws and anchors provided to mount sensor. 180 Wall-Mount Sensor & Hallway Sensor 90 Corner-Mount Sensor 3M and Command are trademarks of 3M Company.