MOLSON S BANK BUILDING 166 EAST HASTINGS STREET, VANCOUVER, BC

Similar documents
room data sheet CORDOVA RESIDENCE 1/11 54 EAST CORDOVA STREET, VANCOUVER, BC RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet MARR HOTEL 401 POWELL STREET, VANCOUVER, BC 1/9 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet GASTOWN HOTEL 110 WATER STREET, VANCOUVER, BC 1/11 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet TAMURA HOUSE 396 POWELL STREET, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet MARBLE ARCH HOTEL 518 RICHARDS STREET, VANCOUVER, BC 1/14 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

room data sheet ORANGE HALL 341 GORE AVENUE, VANCOUVER, BC 1/8 RESIDENTIAL ROOM RM DIVISION ELEMENT REQUIREMENT

Kirkstall Brewery Inventory

1152 Vinetta - Des Peres The Wakefield Model $634,900

QUALITY FEATURES Trent 24 7 & ascot semi-detached

MAINTENANCE STANDARD LABOR CHARGE ESTIMATE AMOUNTS

Food Premises - Structural Specifications

EQUIPMENT GUIDE LIST - CHAPTER

MD-CU 29 4 ANTIMICROBIAL COPPER ALLOYS AND ASSOCIATED FABRICATED PRODUCTS MASTER LABEL AND ASSOCIATED FABRICATED PRODUCTS

You ll Love Life In A New Pentrex Home!

Executive Townhome FOR SALE 38 SAN REMO TERRACE. 38 San Remo Terrace Mimico Village

Use a minimum loading pad 6' curb length of a hard surface to connecting curb and sidewalk.

University of Delaware

SPACE TYPE: JUDICIAL CHAMBER

1426 Hinman Ave Evanston, IL

Bath Planning Worksheet

Where value-oriented meets family-oriented.

Deluxe Inclusions. Harrington Homes reserves the right to change designs and inclusions without notice.

Modern Exteriors Stylish Kitchens Designer Bathrooms Comtemporary Living Fixtures & Finishes Schedule Inclusions Brochure

Make Ready Estimate. Total Tenant Charges $0

2016 CALIFORNIA CODES KITCHEN, BATH & LAUNDRY REMODEL REQUIREMENTS

$759, Vinetta, Des Peres You ll Love Life In A New Pentrex Home! ~ Wakefield 1.5 Story Model ~

SCHEDULE C1 SALES ASSOCIATE COPY DINING LIVING / SLEEPING 18'-0" 9'-4" W/D

KCKHA PRICE LIST 2015

210 Ironstone Court. Above information is believed to be accurate but is not warranted. Multiple Listing Service Property, Ottawa Real Estate Board

Residential Accessibility Checklist - for Unit Types A and B With Connecticut Amendments Type A Units Accessibility Requirements rev.

AGING IN PLACE CHECKLIST Use this checklist to identify fall hazards and accessibility for the homeowner and family members.

1008 Twin Pine - Des Peres Wakefield Model $689,305

SPACE TYPE: CHILD CARE

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

The ocean Estates collection

DESIGNER KITCHEN WITH PREMIUM APPLIANCES 1407 & 1409 Military Trail Features & Finishes 1. Open concept kitchen with NEFF designer cabinetry and Caesa

FRESNO COUNTY HUMAN SERVICES SYSTEM ENVIRONMENTAL HEALTH SYSTEM P.O. Box Fresno, CA Telephone (209)

Plan 1. Single Story. zz Single-Story. zz 2 Bedrooms. zz Den. zz 2 Baths. zz 2-Car Garage. zz Optional Bedroom 3. zz 1,518 Square Feet

EXCEL HOMES WENTWORTH in MountainView. MAIN FLOOR 1476 sq. ft. FRONT GARAGE SEMI-ESTATE HOME BUNGALOW. excelhomes.ca

YOU LL LOVE LIFE IN A NEW PENTREX HOME! $845,075

FOOD SERVICE May 6, 2016

Newberry. Foundation Framing

Tivoli s Newest Custom Home... The Magnolia Magnolia Street Sarasota, FL

YOU LL LOVE LIFE IN A NEW PENTREX HOME!

Universal Design Checklist

SPECIFICATIONS ANNEXURE C TYPE A2 HOMES LIST OF

EXHIBIT A-1 CITY OF BELLFLOWER JANITORIAL MAINTENANCE SPECIFICATIONS

Now that you have given your 30 Day Notice to Vacate, what are the next steps?

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

NANO LIVING NANO TERRACE FINISHES SPECIFICATION

28', 32' AND 42' SERIES FLOOR PLANS

PATIENT CARE Single Wardrobe, Open Single Wardrobe, Door Double Wardrobe, Open. Double Wardrobe, Doors (shown) 5232 (reversed)

Introducing... The Lake Country Series. 18 Wide Single Section Homes. ... our WIDEST single section homes! Canada. Proudly made in

All Waters Edge homes come with the following standard features throughout:

Damaged Item Replacement Price List

UNIT TYPES: B (1 beds) C (2 beds) D (3 beds) E & F (Penthouse)

TERRACE VIEW APARTMENTS

SECTION 7 ~ PATHOLOGY GROSSING STATIONS

HUNTER HOUSING AND SUPPORT DEMONSTRATION PROJECT

Proudly made in. Canada. to Canadian Standards. The Columbia Series. 14 Wide Single Section Homes

The Lake Country Series

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

Sudbury Kitchens DESIGN SURVEY

FRIDGE BEDROOM 2 CLOSET MASTER BATH DINING ROOM

UNIVERSITY OF LONDON. Halls of Residence. List of Common Charges 2017/18

Camden. Included Features. Prices are non-negotiable. Continued on Back ATTRACTIVE INTERIORS:

Apartment Inventory Check-list

Plan 2y. First Story. Second Story. Two-Story 4 Bedrooms Loft Exercise Room 3 Baths 2-Car Garage Optional: Bedroom 5 & 6 2,611 Sq. Ft.

Aging-In-Place Remodeling Checklist

Pre-Delivery Orientation (PDO)

Damaged Item Replacement Price List

Elegant. Affordable.TM YOUR HOME BY THE NUMBERS

You can choose one or all of the items from the IKEA Installation Service Menu. For further information, contact us at your local store.

Nims Village New Home Features

* Comfortable Lifestyle * * Affordable Quality *

About This Model. Series: Rockbridge Modular Homes Model: RJ501A Grand Rockwell. Style: Ranch / Bedrooms: 4 / Bathrooms: 2 / Square Feet: 2280.

TERRACE VIEW APARTMENTS

SCHEDULE OF FINISHES AND OUTLINE SPECIFICATIONS

TERRACE VIEW APARTMENTS

14609 Delmar Street The Pavilions Estates of Leawood

POWDER ROOM. BLACKCOMB PLAN TYPE BE 3 Bedrooms, 2 1 /2 Bathrooms Approx 1,392 sq. ft.

Mechanical Inspection Plumbing

SPECIFICATIONS ANNEXURE C TYPE B2 HOMES LIST OF

sjvhomes.com Quality Pfister chrome plumbing fixture Refrigerator space plumbed for ice-maker Quality Pfister chrome plumbing fixture

20 KENRIDGE AVENUE TORONTO, ON

THE CROWN SERIES. Coco, Jackson & Myrtle Floorplans REV *With Craftsman Package

Cleaning Checklist and Instructions

About This Model. Series: Timberland Ranch Model: TL815A. Style: Ranch / Bedrooms: 3 / Bathrooms: 2 / Square Feet: Notes:

Procurement Department ADDENDUM # 1

You can choose one or all of the items from the Installation Service Menu.


PLAN REVIEW SUBMITTAL GUIDE

Classic Collection Features

ATTACHMENT A - ITEM DETAIL

TERRACE VIEW APARTMENTS

Selection Sheet st St st St, Pittsburgh PA 15201

About This Model. Series: Aurora Classic Ranch Modular Model: AW420A Savanna II. Style: Ranch / Bedrooms: 4 / Bathrooms: 2 / Square Feet: 2280.

JANITORIAL SPECIFICATIONS

CHARGES FOR REPAIRS AND SERVICES Please note prices are subject to change without prior notice.

Landscape Includes sprinkler system Irrigation, system maintenance, and landscape upkeep are all included in H.O.A. dues

Transcription:

RESIDENTIAL ROOM Window Provide an operable window New pressed metal door, 20 min. FPR, in new metal buck or existing wood frame, made good Proximity access control technology door hardware, closer in protective box/grille to prevent fi nger ingress and damage, wall-mounted door stop, door peep-hole fi nished GWB & paint. fi nished GWB & paint. New sheet vinyl w/ cove edges & cap New free-standing stainless steel counter unit with integral single or double compartment basin and combined hot and cold water supplies, overfl ow, stainless steel or tile back-splash, stainless steel counter top with raised edge to impede drips, double stainless steel doors enclosing a double height shelving unit, solid wood frame and legs to ensure storage items are a minimum of 8 above the fl oor line, sheet stainless steel caps at the feet and to come with attachment clips to securely fasten to the wall. The Ikea Varde is an acceptable unit. New stainless steel wall mounted shelf unit consisting of two shelves, min. 4-0 long, with support diagonal brackets for secure wall anchorage, and each shelf to come with raised edges on exposed sides to impede drips. The Ikea EKBY Robert shelf unit is an acceptable unit. Single lever hot/cold faucet with rotatable gooseneck trim New hydronic heating system utilizing the existing refurbished cast iron radiators, unless directed otherwise by the Authority. Each residential room to have its own control of the heating system. New surface mounted vandal resistant luminaire controlled by a light switch located at the unit entry door. Provide new duplex receptacles as required by CEC. In addition to code requirements, provide: 2 new dedicated duplex receptacles for fridge and microwave, New ground fault current interrupter duplex receptacle by the vanity sink 1 voice and data line 1 new cable television outlet, locate by general duplex receptacle in room. New combined fi re alarm heat/smoke detector. 1/11 s SRO Renewal Initiative

ADMIN/CONTROL DESK Interior Glazing New pressed metal door, 20 min. FPR in new metal door buck Provide a minimum of 12 sq.ft. (1.12 sq.m) of 1/4 (6 mm) tempered glass oriented to the lunch room or amenity space. Repair and refi nish existing plaster/gwb fi nishes, or provide new fi nished GWB & paint. New sheet vinyl w/ cove edges & cap New millwork computer station with laminate surfaces and convenient and adequate electrical receptacles, integral task lighting and communications outlets. Integral to the workstation millwork should be a higher countertop serving as a sill for vertical or horizontal operating glazed and lockable security window of minimum 1/4 tempered glass and 24 sq.ft. (2.23 sq.m) New ventilation as per ASHRAE 62.1. System may be stand-alone or part of the corridor pressurization ventilation system, as well as recommissioned cast iron radiator for heat, unless otherwise directed by the Authority. Radiator temperature control in room. New surface mounted luminaires controlled by occupancy sensor switch. Each computer/work station will be provided with a new duplex receptacle and new voice and data outlet. Provide new duplex receptacles and voice and data outlets to meet room specifi c equipment needs. One new duplex receptacle will be provided for general use. 2/11 s SRO Renewal Initiative

PROGRAM MANAGER S OFFICE New pressed metal door, 20 min. FPR in new metal door buck Repair and refi nish existing plaster/gwb fi nishes, or provide new fi nished GWB & paint. Repair and refi nish existing plaster/gwb fi nishes, or provide new fi nished GWB & paint. New sheet vinyl with cove edge and cap New ventilation as per ASHRAE 62.1. System may be stand-alone or part of the corridor pressurization ventilation system, as well as recommissioned cast iron radiator for heat, unless otherwise directed by the Authority. Radiator temperature control in room. New surface mounted luminaires controlled by occupancy sensor switch. Each computer/work station will be provided with a new duplex receptacle and new voice and data outlet. Provide new duplex receptacles and voice and data outlets to meet room specifi c equipment needs. One new duplex receptacle will be provided for general use. 3/11 s SRO Renewal Initiative

New pressed metal door, 20 min. FPR in new metal door buck Repair and refi nish existing plaster/gwb fi nishes, or provide new fi nished GWB & paint. Repair and refi nish existing plaster/gwb fi nishes, or provide new fi nished GWB & paint. New sheet vinyl with cove edge and cap Double door set of lockable millwork upper cabinets with laminate outer surfaces Wall mount lavatory New ventilation as per ASHRAE 62.1. System may be stand-alone or part of the corridor pressurization ventilation system, as well as recommissioned cast iron radiator for heat, unless otherwise directed by the Authority. Radiator temperature control in room. STREET NURSE S OFFICE New surface mounted luminaires controlled by occupancy sensor switch. Each computer/work station will be provided with a new duplex receptacle and new voice and data outlet. One new duplex receptacle will be provided for general use. 4/11 s SRO Renewal Initiative

KITCHEN New metal slab door of the required FPR, with a 12 x12 wired glass lite, in a steel frame. The top of the window is to be at 5-10, and it is to be centered on the width of the door., closer in protective box/grille to prevent fi nger ingress and damage, wall-mounted door stop, 12 x12 wired glass lite. New sheet vinyl w/ cove edges & cap Millwork: laminate faced millwork and laminate countertops with a double compartment sink and integral splashback. Arrange the kitchen cabinetry for adequate preparation space between the range and sink, accommodation for a full size fridge, dishwasher and a microwave oven shelf, and lockable millwork drawers and doors. Single lever hot/cold faucet New hydronic heating system utilizing the existing refurbished cast iron radiators for heat, unless otherwise directed by Authority. New kitchen exhaust and hood for the domestic range or cooktop. New surface mounted vandal resistant luminaires controlled by occupancy sensor switch. Two new duplex split receptacles will be provided and mounted above the kitchen counter top. Provide new electrical receptacles to meet specifi c kitchen equipment needs. 5/11 s SRO Renewal Initiative

AMENITY New pressed metal door, 20 min. FPR, in new metal buck or existing wood frame, made good Closer in protective box/grille to prevent fi nger ingress and damage, wall-mounted door stop, new proximity access control technology door hardware New sheet vinyl w/ cove edges & cap New fl ush mount tv on wall brackets New wall counter supported on wall brackets at high stool height New millwork computer desk with two work stations with incorporated privacy barriers, cord holes and pull-out keyboard tray. Millwork to be all laminate outer face and with caulked kick plates at fl oor. Lockable cabinet on legs for games, books and general storage Optimum layout of comfortable seating as space permits for the number of users as specifi ed in appendices and in consultation with the Authority. New ventilation as per ASHRAE 62.1. System may be stand-alone or part of the corridor pressurzation stystem. New hydronic heating system utilizing the existing refurbished cast iron radiators for heat, unless otherwise directed by the Authority. Lockable thermostat/sensor for separate control of HVAC systems. New surface mounted vandal resistant luminaires controlled by occupancy sensor switch. Each computer/work station will be provided with a new duplex receptacle and new voice and data outlet. Each TV will be provided with a new duplex receptacle and cable and data television outlet. Two new duplex receptacles will be provided for general use. 6/11 s SRO Renewal Initiative

LAUNDRY Interior Glazing New pressed metal door, 20 min. FRR, in new metal buck or existing wood frame, made good Provide a minimum of 12 sq.ft. (1.12 sq.m) of 1/4 (6 mm) tempered glass oriented to the lunch room, administration offi ce or Program Manager s offi ce. New sheet vinyl w/ cove edges & cap /EQUIPMENT Millwork: Clothes folding table with a laminate countertop Waste standpipe for washers, hot and cold supply to washers and to new laundry sink New hydronic heating system utilizing the existing refurbished cast iron radiators for heat, unless otherwise directed by Authority. Radiator temperature control in room. New dryer exhaust system to connect to new dryers, complete with lint traps. New surface mounted vandal resistant luminaires controlled by occupancy sensor switch. Provide new electrical receptacles to meet specifi c room equipment needs. One new duplex receptacle will be provided for general use. 7/11 s SRO Renewal Initiative

NON-ACCESSIBLE W/C New pressed metal door, 20 min. FRR, in new metal buck or existing wood frame, made good Lower: Abuse resistant GWB to be used from fl oor level up to approximately 4-0 above fi nished fl oor. Small painted wood trim members to be installed at drywall joint approximately 4-0 above fi nished fl oor level to simulate a wainscoting appearance. Upper: Provide new fi nished paperless GWB & paint. Provide new fi nished paperless GWB & paint. New sheet vinyl w/ cove edges & cap Bench, toilet tissue holder, mirror, towel/clothes hooks, soap dispenser and paper towel dispenser, lockable needle disposal bin New shower trim with thermostatic single lever shower mixing valve and tamper-proof shower head. New water closet, lavatory and trim. New hydronic heating system utilizing the existing refurbished cast iron radiators for heat, unless otherwise directed by Authority. Radiator temperature control in room. New surface mounted vandal resistant luminaires controlled by occupancy sensor switch. Luminaires will be suitable for the environment where they will be installed. 8/11 s SRO Renewal Initiative

CORRIDOR/CIRCULATION As required by code compliance repquirements, new pressed metal door, 20 min. FPR, in new metal bucks Hardware tied to fi re alarm, and panic bar or paddle latch hardware. Lower: Abuse resistant GWB to be used from fl oor level up to approximately 4-0 above fi nished fl oor. Small painted wood trim members to be installed at drywall joint approximately 4-0 above fi nished fl oor level to simulate a wainscoting appearance. Transom windows: insert 1/2 cement board over existing glazing. Upper: Repair and refi nish existing plaster/gwb fi nishes, OR provide new New sheet vinyl w/ cove edges & cap inlaid panels for aesthetics and wayfi nding 23 HEATING VENTILATING & AIR CONDITIONING New corridor ventilation and pressurization system. New hydronic heating system utilizing the existing refurbished cast iron radiators for heat, unless otherwise directed by Authority. 26 ELECTRICAL New surface mounted vandal resistant luminaires. New duplex receptacles will be provided for general use. Maximum spacing between receptacles will be 25 feet. 9/11 s SRO Renewal Initiative

JANITOR S CLOSET New pressed metal door, 20 min. FPR, in new metal door buck New sheet vinyl with cove edge and cap Wall mount shelving for cleaning products and janitorial equipment Floor mount mop sink with separate hot and cold water supplies New surface mounted luminaire controlled by occupancy sensor switch. One new ground fault current interrupter duplex receptacle. 10/11 s SRO Renewal Initiative

BASEMENT STORAGE New pressed metal door (if interior access from a stair or elevator lobby) 20 min. FPR, in new metal buck or existing wood frame, made good, or exterior metal slab door if exterior Clean existing concrete foundation wall and prepare and paint existing plaster walls as required Clean and seal existing concrete fl oor Reinstate GWB fi re separation, prepare and paint Split level wire mesh cages adequate for all residents, oriented for the optimal space usage Heavy Duty metal shelving within a lockable wire mesh enclosure, located for the optimal space useage Anchored bike racks to accommodate 20 bicycles Provide suffi cient hydronic heating to sustain a minimum 15 degree C room temperature New surface mounted vandal resistant luminaires controlled by occupancy sensor switch 11/11 s SRO Renewal Initiative