Sensor Product Guide. Smart Sensing Control Solutions

Similar documents
Energy Management Products

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

SECTION. Occupancy Sensors & Lighting Control Products

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Arrow Hart. Universal Dimmers and Sensors. Eaton s Arrow Hart. Reliable lighting control for commercial installations

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Applications Cookbook 2015 IECC Version 3.0 FOR REFERENCE ONLY

Integrated Classroom Control System. Installation and Operation Manual

Occupancy Sensor Selection Guide

Applications Cookbook ASHRAE Standard Version 5.0 FOR REFERENCE ONLY

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

Mini Product Guide.

Maestro 0 10 V Dimmer Sensor

Energy Management. The Smart Choice for Lighting Control and Energy Solutions

Residential Occupancy & Vacancy Sensors

ENERGY EFFICIENCY EXPERTS

Versatile wall switch sensors maximize payback and simplify code compliance

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

2015 IECC. Design Guide for Smart Lighting Control and Energy Solutions

Never forget to turn the lights off again. Motion Sensors

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

California Title Design Guide for Smart Lighting Control and Energy Solutions

Product Bulletin for Decora Rocker Slide Controls

IllumaTech Innovations

IP65 High Bay Dual Sense Sensor

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

miniz Quick Start Guide

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

Maestro Occupancy Sensing Switch

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Lighting and Fan Speed Controls

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

Tri-level Control HF Sensor

DeVos Place, Architect: Ellerbe Becket

Installation Instructions

H-MoSS. Tomorrow s Technology Today! H-MOSS Occupancy and Vacancy Sensors. Adaptive Technology Dual Technology Ultrasonic Passive Infrared

Maestro Dual-Circuit Occupancy Sensing Switch

0ACDT2000MV Ultasonic/Infared Occ Sensor

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Wherever the best is needed. Sensors for professionals.

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Maestro Occupancy Sensing Switch

IP65 High Bay Dual Sense Sensor

Occupancy Sensor Operation with Lighting Fixtures

Section D. H-MOSS Occupancy Sensors Index. Wall Switches. Wall and Ceiling Mount. Sensors. Residential and Vacancy. Sensors

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

Maestro Occupancy Sensor C L Dimmer

Interior Control Solutions

Wireless Plug Load Control

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

Indoor Controls. SpaceWise SWZG2. Wireless technology

Tri-level Control Sensor

AHAC-DT MicroSet dual tech low/line voltage ceiling sensors

Lutron Sensor Solutions. Lutron energy-saving light controls for your home or office. simple. affordable. energy-saving.

Dimmer/Switch with Occupancy and Vacancy Sensor

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

Maestro Occupancy sensing switch

National Grid Small Business Program Rebate Manual

Maestro Occupancy sensing switch

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

Vive PowPak Fixture Controls

Wireless Wall-Mount Sensor

Product Specifications Dialog Room Controller* (*patent pending)

VESICA LINEAR SUSPENDED VES L

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

IN2 Lighting Control Devices

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

2025 Lavoisier, #135 Quebec, Quebec G1N 4L6 T F E. cristalcontrols.

Tualatin Valley Fire & Rescue Finance Department SW 70 th Ave., Tigard, OR Phone: , Fax:

INTEGRATED LIGHTING CONTROLS

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

The Power To Supply... All Your Electrical Products

SECTION LIGHTING CONTROL DEVICES EATON S LIGHTING SYSTEMS (FORMERLY COOPER CONTROLS) VACANCY/OCCUPANCY SENSORS

Sensors and Detectors

Ever evolving energy code requirements and the large demand for energy

DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSOR SWITCH (WS XX DT XX/WS OS DTDR XX)

Occupancy and Vacancy Sensors

Applied Lighting Controls

Product Specifications

LED Control Solutions

BRIGHTEN YOUR LIFE. LED Troffer Light. Benefits. RoH S BB-RTGD-XXX-A-XX-D

Supporting the Requirements of EPAct 2005 Tax Deductions

The Power To Supply... All Your Electrical Products

SPECIFICATION SUBMITTAL

Alliance 4 - ALI4 LED 4 Linear High Bay

Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Lighting Control Solutions for Parking Facilities

Wireless Wall-Mount Sensor

Reduce lighting energy costs with controls

Installation Instructions

design guide for wireless l i g h t i n g c o n t r o l

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

LED High Bay. 150W LED High Bay GLC-ANHB-150W-1. PERFORMANCE LED Chip Lumen Output (IES) Power Consumption Efficacy (IES) Beam Angle

Tri-level Control HF Sensor

Code Review TITLE PRESENTED BY POURIA NIKNAM

Transcription:

Sensor Product Guide Smart Sensing Control Solutions

Service and Support During Every Step of the Process. Only Leviton has the service and support to help you create a lighting control system that does exactly what you want it to do while saving electricity, meeting codes and standards, and even garnering rebates. Exclusive SUPPORT Resources: Occupancy sensor layout services have a team of experts create occupancy sensor layouts at no cost to you directly on your CAD drawings, complete with a List of Equipment within an average turnaround time of 3 business days* go to portal.leviton.com Dollars & Sensors get an accurate estimate of your energy-savings potential with this exclusive payback analysis tool go to www.dollarsandsensors.com ez-learn get sensor smart in just 9 minutes from the comfort of your home or office with this exclusive 24/7 online training go to www.leviton.com/ezlearn Lighting control specialists at your disposal Field service engineers for top-level support Factory commissioning service Dedicated technical support via phone at 8 959-64 Sensing Control * Average turnaround time based on projects for up to 2 sensors per system. 2

WIRELESS SELF-POWERED SENSORS LevNet RF 92 MHz Wireless Self-Powered Sensors are part of LevNet RF s complete line of self-powered solutions. The occupancy sensors have built-in solar cells that draw on available ambient light within a space to power themselves and can operate for up to 72 hours in total darkness. The self-powered sensor design also overcomes the placement and coverage challenges of traditional sensors. Self-powered sensors enable flexible placement, allowing sensors to be mounted wherever needed without the complexity of moving or installing new wiring. COMMERCIAL GRADE Energy Harvesting Wireless Solutions Description Cat.. Coverage Color LevNet RF 92 MHz Low Profile Self-Powered PIR Ceiling Mount Occupancy Sensor WSC12-M9N LevNet RF 92 MHz Self-Powered WSWDR-H9W PIR Wall Mount Occupancy Sensor *Multiple lenses included, see data sheet for more coverage information Requires a LevNet RF load receiver device to operate 36, 12SF (111.48SM) 18, 16*SF (148.64SM) W WSC12 15 1 1 15 1 16 14 11 9 4 3 3 4 9 11 14 WSC12 Field of View (in feet) 16 LONG RANGE Top View 22 ft (6.7 m) 11 ft (3.4 m) Side View 11 ft (3.4 m) 22 ft (6.7 m) 3 ft (1 m) 6-8 ft (2.1-2.4 m) 3 ft (1 m) 77 27 7 ft (2.2 m) 7 ft (2.2 m) 25 ft 35 ft (7.6 m) (1.7 m) 25 ft 35 ft (7.6 m) (1.7 m) 21.5 14 1 ft (3.48 m) 1 ft (3.48 m) Minor Motion Major Motion WSWDR Field of View (in feet) 6.5 Center Line 15 ft (45.7 m) 15 ft (45.7 m) WSWDR Sensing Control Self-Powered Wireless Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. www.leviton.com/sensors 3

Sensing Control Wall Switch Residential Decora Residential Grade Wall Switch Infrared Occupancy and Vacancy Sensors Description Cat.. Color Rating Decora Wall Switch PIR Occupancy Sensor, Single-Pole, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch PIR Vacancy Sensor, Single-Pole, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch PIR Occupancy Sensor, Single-Pole, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch PIR Vacancy Sensor, Single-Pole, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch PIR Occupancy Sensor, Single-Pole or 3-Way, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch PIR Dimming Occupancy Sensor, Single-Pole or 3-Way, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch PIR Dimming Vacancy Sensor, Single-Pole or 3-Way, 18 Field of View, 9SF (83.61SM) coverage Decora Wall Switch Relay Occupancy Sensor, Single-Pole or 3-Way, 18 Field of View, 9SF (83.61SM) coverage, neutral required Decora Wall Switch Relay Vacancy Sensor, Single-Pole or 3-Way, 18 Field of View, 9SF (83.61SM) coverage, neutral required Sensor Remote, 12V AC, Manual-ON, Auto-OFF for use with IPS15 or IPV15 Sensor IPS2-1L W, I, T 3W Incand/FL Ballast 15W LED/CFL, IPV2-1L W,T 1/6 HP Motor IPS5-1L IPV5-IL IPS6-1L IPSD6-1L IPVD6-1L IPS15-1L IPV15-1L Z Comes packaged with three colors: White, Ivory and Light Almond. Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. Visit www.leviton.com/sensors for more information. Decora Residential Grade Wall Switch Humidity Sensor and Fan Control Description Cat.. Color Rating Humidity Sensor & Fan Control IPHS5-1L W, I,T Z W Z 6W Incand/FL Ballast 15W LED/CFL, 1/6 HP Motor 6W Incandescent, 15W LED/CFL 18W Incandescent, 6W LED/CFL, 18VA Fluorescent Ballast, 1/2 HP IPVR-1L Load Rating 6W Incandescent, 15W LED/CFL 4VA MLV/Fluorescent, 1/6 HP (3A) Fan IPS5-1L IPVD6-1L 5ft 1.5m 6ft 1.8m 3ft 9.1m 6ft 1.7m 5ft 1.5m IPHS5-W 8ft 2.6m 27ft 8.4m 3ft 9.1m 4ft 1.2m 6ft 1.7m 7ft 2.1m 5ft 1.5m 3ft 9.1m 4ft 1.4m Field-of-View (Horizontal) Field-of-View (Side, Vertical) 4

Decora Commercial Grade Wall Switch Infrared Occupancy and Vacancy Sensors* Description Cat.. Color ** Rating Coverage Decora Wall Switch PIR Occupancy Sensor ODS6-ID W, I Decora Wall Switch PIR Occupancy Sensor 347V Only Model ODS1-I3 Incandescent: 6W @ 12V, Fluorescent: 8VA @ 12V 15VA @ 277V, 5/6Hz Motor: 1/4 HP @ 12V Incandescent: 347W @ 347V Fluorescent: 347W @ 347V 5/6 Hz Motor: 1/4HP @ 347V Decora Wall Switch PIR Occupancy Sensor Decora Wall Switch PIR Vacancy Sensor ODS1-ID ODS1-TD W, I, T, G, E, R W, I, T Incandescent: 8W @ 12V Fluorescent: 12VA @ 12V, 27VA @ 277V. Decora Wall Switch PIR - Occupancy Sensor 5/6Hz ODS1-IQ W, I, E Auto-ON/Auto-OFF Only Model Motor: 1/4HP @ 12V Decora Wall Switch PIR Occupancy Sensor with Self-Adaptive Decora Wall Switch PIR Vacancy Sensor with Self-Adaptive Decora Dual-Relay Wall Switch PIR Occupancy Sensor with Self-Adaptive. Default setting = Conference Room Mode*** Alternate setting = Classroom mode**** Decora Wall Switch PIR Occupancy Sensor with LED Night Light Decora ç Wall Switch PIR with LED Night Light, CA Title 24 - Vacancy Model ODS15-ID ODS15-TD ODSD-ID OSSNL-ID OSS1-IN 18, 21SF (195.1SM) *Consult with factory for 28, 22, 23, and 24V load ratings. **Add to end of catalog number suffix for color of switch: White (W), Ivory (I), Light Almond (T), Gray (G), Ebony (E) and Red (R) available on select models. Wallplates sold separately. ***In Conference Room Mode, both primary and secondary relays respond to ambient light override. ****In Classroom Mode, primary relay responds only to ambient light override Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. W W, I, T, G, E W, I, T W, I, T, G, E, R W, I, T, G, E W, I, E Incandescent: 18W @ 12V Fluorescent: 18VA @ 12V, 4VA @ 277V 5/6Hz Motor: 1/4HP @ 12V Primary Relay Fluorescent: 12VA @ 12V, 27VA @ 277V; Incandescent: 8W @ 12V. Secondary Relay Fluorescent: 8VA @ 12V, 12VA @ 277V; Incandescent: 8W @ 12V. 5/6Hz Incandescent: 8W @ 12V Fluorescent: 12VA @ 12V, 27VA @ 277V 5/6Hz Motor: 1/8 HP @ 12V Protective Cage for Wall Switch Sensors OSWWG-PW 18, 12SF (111.48SM) Sensing Control Wall Switch Commercial Decora Wall Switch - Lev-Lok Models, 2A Description Cat.. Color Rating Decora Wall Switch PIR Occupancy Sensor - Lev-Lok Model Decora Wall Switch PIR Occupancy Sensor - Lev-Lok Model Decora Wall Switch Multi Occupancy Sensor with Netural - Lev-Lok Model MDS1-ID MDS15-ID MSSMT-GD W,I,T,G,E Incandescent: 8W @ 12V. Fluorescent: 12VA @12V, 27VA @ 277V. 5/6Hz Motor: 1/4HP @ 12V Incandescent/Tungsten: 8W @ 12V. Fluorescent: 12VA @ 12V, 27VA @ 277V. 6Hz Motor: 1/4HP @ 12V Wiring Modules for use with Lev-Lok Sensors Description Cat.. Color Stranded MSPSW-XST Yellow Solid MSPSW-XSD Yellow ODS6-INW/ODS6-IDW ODS1-IDW/ODS15-IDW OSSNL-IDW ODSD-IDW www.leviton.com/sensors 5

DECORA MULTI-TECHNOLOGY WALL SWITCH OCCUPANCY AND VACANCY SENSORS Sensing Control Wall Switch Commercial Decora Commercial Grade Wall Switch Multi- (PIR & U/S) Occupancy and Vacancy Sensors* Description Cat.. Color Rating Coverage Decora Wall Switch Multi- Occupancy Sensor with Self-Adaptive OSSMT-MD W, I, T, G, E, R Decora Wall Switch Multi- Vacancy Sensor with Self-Adaptive Decora Wall Switch Multi- Occupancy Sensor with Neutral - Auto-ON/Auto-OFF Only Model Decora Wall Switch Multi- Occupancy Sensor with Self-Adaptive - Auto-ON/Auto- OFF Only Model Decora Wall Switch Multi- Occupancy Sensor with Self-Adaptive - 347V Only Model Decora Wall Switch Multi- Occupancy Sensor with no neutral wire required for installation Decora Wall Switch Multi- Vacancy Sensor with Neutral Decora Dual-Relay Wall Switch Multi- Occupancy Sensor Decora Dual-Relay Wall Switch Multi- Occupancy Sensor with no neutral wire required for installation Protective Cage for Wall Switch Sensors OSSMT-TM OSSMT-GQ OSSMT-MQ OSSMT-M3 OSSMT-GD OSSMT-GT OSSMD-MD OSSMD-GD W, I, T W, I, E W, I W, I, T, G, E, R W, I, T W, I, T, G, E *Consult with factory for 28, 22, 23, and 24V load ratings. Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. Incandescent/Tungsten: 8W @ 12V Fluorescent: 12VA @ 12V, 27VA @ 277V Motor: 1/4HP @ 12V 5/6Hz Incandescent/Tungsten: 8W @ 12V Fluorescent: 12VA @ 12V, 27VA @ 277V, 15VA @347V Motor: 1/4HP @ 12V Incandescent/Tungsten: 8W @ 12V. Fluorescent: 12VA @ 12V, 27VA @ 277V. Motor: 1/4HP @ 12V, 5/6Hz Primary Relay Fluorescent 12VA @ 12V, 27VA @ 277V Incandescent: 8W @ 12V Secondary Relay Fluorescent: 8VA @ 12V, 12VA @ 277V; Incandescent: 8W @ 12V Motor: 1/4HP @ 12V, 5/6Hz OSWWG-PW W 3 2 18, 24SF (222.97SM) OSSMT-MDW/OSSMT-GDW OSSMD-MDW/OSSMD-GDW 2 3 5 4 2 4 OSSMD/OSSMT/MSSMT Field of View (in feet) Major Motion, PIR Major Motion, PIR Major Motion, U/S Major Motion, U/S 6

LINE VOLTAGE OCCUPANCY/VACANCY SENSORS Self-Contained Infrared Ceiling Mount Occupancy Sensors Description Cat.. Color Rating Coverage Self-Contained Ceiling Mount PIR Occupancy Sensor and Switching Relay, 12V Self-Contained Ceiling Mount PIR Occupancy Sensor and Switching Relay, 22V Self-Contained Ceiling Mount PIR Occupancy Sensor and Switching Relay, 277V ODCS-I1W ODCS-I2W ODCS-I7W W Incandescent: 1W @ 12V Fluorescent: 1VA @ 12V Motor: 1HP @ 12V 5/6Hz Incandescent: 1W @ 22V Fluorescent: 5VA @ 22V For 5Hz AC only. Fluorescent: 27VA @ 22V 5/6Hz 36, 53SF* (49.23SM) ODCS-I1W Protective Cage for Ceiling Mount Sensors ODCCG- *When surface mounted on standard, 8 foot ceiling. Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. ODCCG- 13 13 Sensing Control Line Voltage 8 13 7 3 3 7 13 ODCS-xx Field of View (in feet) www.leviton.com/sensors 7

LINE VOLTAGE SENSORS Sensing Control Line Voltage Line Voltage Sensors with OPB15 Power Base Adaptor Combos Description Cat.. Color Rating Coverage Line Voltage Wall Mount Multi- Occupancy Sensor with Power Base Combo Line Voltage Wall Mount PIR Wide View Occupancy Sensor with Power Base Combo Line Voltage Wall Mount PIR Wide View Occupancy Sensor with Power Base Combo Line Voltage Wall Mount PIR Long Range Occupancy Sensor with Power Base Combo Protective Cage for Wall Mount Sensors 16 16 58 31 ODW12-MDW ODWWV-IDW ODWHB-IDW ODWLR-IDW W 15A Incandescent, Electronic or Magnetic Fluorescent Ballast Motor: 3/4 HP @ 12V, 277V @ 2HP OSWCG-PW Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. 58 29 12SF (111.48SM) 115, 25SF (232.26SM) 55ft., 7ft side @ 3ft high (16.76m x 2.13m side @ 9.14m high) 1ft, 11 @ 1ft high (3.48m, @ 3.4m high) ODW12-MDW 31 29 58 Minor Motion, IR Major Motion, IR 58 8 Minor Motion, Ultrasonic Major Motion, Ultrasonic 8 Minor Motion, IR Major Motion, IR 3 8 15 31 68 23 32 3 8 15 31 68 ODW12-MW Field of View (in feet) ODWWV Field of View (in feet) 3.5 16.6 3.5 3 16.6 1 3 13 25 52 ODWHB Field of View (in feet) 14 42 71 1 ODWLR Field of View (in feet) 8

PROVOLT SELF-CONTAINED CEILING MOUNT OCCUPANCY SENSORS DAYLIGHT HARVESTING CAPABLE Provolt Self-Contained Passive Infrared Ceiling Mount Occupancy Sensors Daylight Harvesting Capable Description Cat.. Coverage Color Input Voltage, Rating Provolt Line Voltage Ceiling Mount PIR Occupancy Sensor w/integrated Photocell, High-Density Lens installed, Mid-Range Lens included Provolt Line Voltage Ceiling Mount PIR Occupancy Sensor w/integrated Photocell, Extended Range Lens installed, Mid-Range Lens included ODC4-IDW O2C4-IDW (Dual Relay) ODC15-IDW O2C15-IDW (Dual Relay) 45SF (41.8SM) Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. 15SF (139.35SM) W 12V, 5/6Hz 8A, Electronic Ballast, 8W/VA, Tungsten Ballast, 1/4 HP Motor 23V, 5Hz 6A/6AX, Electronic Ballast, Magnetic Ballast, 12W/VA, 1/3 HP Motor 277V, 5/6Hz 6A, Electronic Ballast, 12VA, 1/3 HP Motor 12 5 5 12 12 Minor Motion, Infrared Major Motion, Infrared 2 1 1 2 12 15 1 5 5 1 15 2 Sensing Control Line Voltage 12 9 7 5 3 3 5 7 9 12 2 15 11 9 5.6 3 3 5.6 9 11 15 2 3 25 2 15 1 5 5 1 15 2 25 3 ODC4-IDW, O2C4-IDW (High Density: Blue Lens) ODC15-IDW, O3C15-IDW, O2C15-IDW, O4C15-IDW (Extended Range: Black Lens) Mid-Range Lens (mounting up to 2 feet) (Included with all PIR and Multi-Tech Models) www.leviton.com/sensors 9

PROVOLT SELF-CONTAINED CEILING MOUNT OCCUPANCY SENSORS DAYLIGHT HARVESTING CAPABLE Provolt Self-Contained Ultrasonic Ceiling Mount Occupancy Sensors Daylight Harvesting Capable Description Cat.. Coverage Color Input Voltage, Rating Provolt Line Voltage Ceiling Mount U/S Occupancy Sensor w/integrated Photocell, Extended Range Lens installed ODC5-UDW O2C5-UDW (Dual Relay) 5SF (46.45SM) 277V, 5/6Hz 5A, Electronic Ballast, 8W/VA, Tungsten Ballast, 1/3 HP Motor Provolt Line Voltage Ceiling Mount U/S Occupancy Sensor w/integrated Photocell, Extended Range Lens installed ODC1-UDW O2C1-UDW (Dual Relay) 1SF (92.9SM) W 23V, 5Hz 6A/6AX, Electronic Ballast, Magnetic Ballast, 12W/VA, 1/3 HP Motor Provolt Line Voltage Ceiling Mount U/S Occupancy Sensor w/integrated Photocell, Extended Range Lens installed ODC2-UDW O2C2-UDW (Dual Relay) 2SF (185.81SM) 277V, 5/6Hz 5A, Electronic Ballast, 12VA, 1/3 HP Motor Sensing Control Line Voltage 8.5 8.5 Minor Motion, Ultrasonic Major Motion, Ultrasonic 8.5 8.5 Minor Motion, Ultrasonic Major Motion, Ultrasonic 5 1 2 17 23 23 17 17 23 ODC5-UDW, O2C5-UDW ODC1-UDW, O2C1-UDW 16 16 Minor Motion, Ultrasonic Major Motion, Ultrasonic 32 22.5 22.5 32 ODC2-UDW, O2C2-UDW 1

Provolt Self-Contained Multi- Ceiling Mount Occupancy Sensors Daylight Harvesting Capable Description Cat.. Coverage Color Input Voltage, Rating Provolt Line Voltage Ceiling Mount Multi- Occupancy Sensor w/integrated Photocell, Extended Range Lens installed ODC5-MDW O2C5-MDW (Dual Relay) 5SF (46.45SM) 12V, 5/6Hz 8A, Electronic Ballast, 8W/VA, Tungsten Ballast, 1/4 HP Motor Provolt Line Voltage Ceiling Mount Multi- Occupancy Sensor w/integrated Photocell, Extended Range Lens installed, Mid-Range Lens included ODC1-MDW O2C1-MDW (Dual Relay) 1SF (92.9SM) W 23V, 5Hz 6A/6AX, Electronic Ballast, Magnetic Ballast, 12W/VA, 1/3 HP Motor Provolt Line Voltage Ceiling Mount Multi- Occupancy Sensor w/integrated Photocell, Extended Range Lens installed, Mid-Range Lens included ODC2-MDW O2C2-MDW (Dual Relay) 2SF (185.81SM) 277V, 5/6Hz 5A, Electronic Ballast, 12VA, 1/3 HP Motor Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. 2 8.5 8.5 2 8 Major Motion, IR Minor Motion, Ultrasonic 2 8.5 8.5 2 8 Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic Sensing Control Line Voltage Major Motion, Ultrasonic 3 5.6 9 11 15 17 2 23 23 2 15 17 11 9 5.6 3 3 5.6 9 11 15 2 17 23 ODC5-MDW, O2C5-MDW (High Density: Blue Lens) ODC1-MDW, O3C1-MDW, O2C1-MDW,O4C1-MDW (Extended Range: Black Lens) 15 2 1 16 5 5 1 8.5 2 Major Motion, IR 15 2 Minor Motion, Ultrasonic 8 Major Motion, Ultrasonic 32 2 22.5 15 11 9 5.5 3 3 5.5 9 11 15 2 22.5 32 3 25 2 15 1 5 5 1 15 2 25 3 ODC2-MDW, O3C2-MDW, O2C2-MDW, O4C2-MDW Mid-Range Lens (mounting up to 2 feet) (Included with all PIR and Multi-Tech Models) www.leviton.com/sensors 11

PROVOLT SELF-CONTAINED CEILING MOUNT VACANCY SENSORS Provolt Self-Contained Ceiling Mount Vacancy Sensors Description Cat.. Coverage Color Input Voltage, Rating Provolt Line Voltage Ceiling Mount PIR Vacancy Sensor 3C15-IDW 4C15-IDW (Dual Relay) 15SF (139.35SM) 12V, 5/6Hz 8A, Electronic Ballast, 8W/VA, Tungsten Ballast, 1/4 HP Motor Provolt Line Voltage Ceiling Mount PIR Vacancy Sensor 3C1-MDW 4C1-MDW (Dual Relay) 1SF (92.9SM) W 23V, 5Hz 6A/6AX, Electronic Ballast, Magnetic Ballast, 12W/VA, 1/3 HP Motor Provolt Line Voltage Ceiling Mount PIR Vacancy Sensor 3C2-MDW 4C2-MDW (Dual Relay) 2SF (185.81SM) Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. 277V, 5/6Hz 5A, Electronic Ballast, 12VA, 1/3 HP Motor Sensing Control Line Voltage ODC2-MDW OXCXX-IDW Flat Light Pipe Angled Light Pipe ODC2-MDW (top view) 12

SELF-CONTAINED FIXTURE MOUNT HIGH-BAY PIR AND INTEGRAL LUMINAIRE OCCUPANCY SENSORS Self-Contained PIR High Bay Occupancy Sensors* Coverage 36 high-bay lens 2:1 spacing to mounting height under 2 ft. and 1.5:1 spacing to mounting height @ 4 ft. 36 low-bay lens 2:1 spacing to mounting height @ 8 ft. to 2 ft. Description Cat.. Models Rating Fixture Mount High-Bay PIR Occupancy Sensor with Two Interchangeable Lenses, for 36º High-Bay, 36º Low Bay OSFHU-ITW OSFHU-CTW 12-23-277-347V OSFHU-I4W 24/48V OSFHU-C4W 12-23-277-347V, Cold Storage 24/48V, Cold Storage Fluorescent: 8VA @ 12V, Fluorescent: 12VA @ 277V, Fluorescent: 15VA @ 347V, 5/6Hz (OSFHU-x4W models only) Motor: 1/4 HP @ 12V Fixture Mount High-Bay PIR Occupancy Sensor with Two Interchangeable Lenses and Light Sensor, Low Voltage OSFHP-ILW 24V Input: 2mA Output: 12mA HVAC: 1A, 3V DC OSFHP-ITW 12-23-277-347V Fixture Mount High-Bay PIR Occupancy Sensor with Two Interchangeable Lenses and Light Sensor Fixture Mount High-Bay PIR Occupancy Sensor with Two Interchangeable Lenses and Alternating Relay Surface Mount High-Bay PIR Occupancy Sensor Coverage 36º 1:1 spacing to mounting height up to 8 ft. OSFHP-I4W 24/48V OSFHD-ITW OSFHD-CTW OSFHD-IAW OSFHD-CAW OSFHS-ITW 12-23-277-347V, Dual Relay 12-23-277-347V, Dual Relay, Cold Storage 12-23-277V Cold Storage 12-23-277-347V Description Cat.. Models Rating Integral Luminaire Fixture Mount PIR Occupancy Sensor Fluorescent: 8VA @ 12V, Fluorescent: 1VA @ 23V AC, Fluorescent: 12VA @ 277V AC, Fluorescent: 15VA @ 347V AC, Fluorescent: 2VA @ 48V AC, 5/6Hz. Motor: 1/4 HP @ 12V Fluorescent: 8VA @ 12V, Fluorescent: 12VA @ 277V AC, Fluorescent: 15VA @ 347V AC, Motor: 1/4 HP @ 12V OSFHU-IW 12-23-277V (Integrated Unit) Incandescent: 598W @ 12V. OSF1-IUW 12-23-277V, Sensor Head Fluorescent: 8VA @ 12V, OSF1-PPW 12-23-277V, Power Pack Fluorescent: 1VA @ 23V AC, Fluorescent: 12VA @ 277V AC, OSFCA-36W 36 Connection Cable 5/6Hz Sensing Control Line Voltage *Consult with factory for 28, 22, 23, and 24V load ratings. Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. OSFHU-ITW OSFHP OSFHD OSFHS OSF1-xxx www.leviton.com/sensors 13

SELF-CONTAINED FIXTURE MOUNT HIGH-BAY PIR AND INTEGRAL LUMINAIRE OCCUPANCY SENSORS Self-Contained Infrared High Bay Occupancy Sensor Accessories Description Cat.. High-Bay Lens for High-Bay Sensors OSFLN-W Low-Bay Lens for High-Bay Sensors OSFLN-B Aisle Lens for High-Bay Sensors OSFLN-E Offset Adaptor Accessory for Fixture-Mount Occupancy Sensor OSFOA-W Offset Adaptor Accessory for High-Bay Occupancy Sensor OSFLO-W Protective Cage for High-Bay Mount Sensors OSFCG-W OSFOA 3 ft 3 ft High Bay 36 Top View 2 ft 1 ft Low Bay 36 Top View 2 ft 1 ft Sensing Control Line Voltage White Lens Side View 1 ft 2 ft 3 ft 2 ft 3 ft 4 ft 3 ft 2 ft 1 ft 1 ft 2 ft 3 ft Blue Lens Side View 1 ft 2 ft 3 ft 8 ft 2 ft 25 ft OSFHU/OSFHP/OSFHD Field of View (in feet) 3 ft 2 ft 1 ft 1 ft 2 ft 3 ft 1' 8' 6' 4' 2' ' 2' 4' 6' 8' 1' 8' 6' 4' 2' ' 2' 4' 6' 8' 1' ' 2' 4' 6' 8' OSF1 Field of View (in feet) 14

CEILING MOUNT MULTI-TECHNOLOGY OCCUPANCY SENSORS Ceiling Mount Multi- Occupancy Sensors and Accessories For Use with Leviton Power Pack or Power Base Adaptor Description Ceiling Mount Multi- Occupancy Sensor Ceiling Mount Multi- Occupancy Sensor Ceiling Mount Multi- Occupancy Sensor Ceiling Mount Multi- Occupancy Sensor with Isolated Relay Ceiling Mount Multi- Occupancy Sensor with Isolated Relay Ceiling Mount Multi- Occupancy Sensor with Isolated Relay Power Base Adaptor 8 8.5 8.5 2 8 2 8.5 8.5 2 8 Cat.. OSC5-MW OSC1-MW OSC2-MW OSC5-RMW OSC1-RMW OSC2-RMW Operating Frequency 4kHz 32kHz 4kHz 32kHz Rating 18, 5SF (46.45SM) 36, 1SF (92.9SM) 36, 2SF (185.81SM) 18, 5SF (464.52SM) 36, 1SF (92.9SM) 36, 2SF (185.81SM) 2 16 16 2 8 Color Off-White White OPB15-DW Off-White Cosmetic Adaptor OPBCA-W Protective Cage for Ceiling-Mount Sensors ODCCG- te: Use low-voltage wiring to connect sensors to OPP2 or OSPxx Power Pack or OPB15 Power Base Adaptor Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. OSC5-MW OSC1/OSC2-MDW Sensing Control Low Voltage 3 5.6 9 11 15 17 2 23 23 2 17 15 11 9 5.6 3 3 5.6 9 11 15 17 2 23 2 15 11 9 5.5 3 3 5.5 9 11 15 2 32 22.5 22.5 32 OSC5-MW Field of View (in feet) OSC1-MW Field of View (in feet) OSC2-MW Field of View (in feet) Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic www.leviton.com/sensors 15

CEILING MOUNT PIR OCCUPANCY SENSORS Infrared Ceiling Mount Occupancy Sensors and Accessories For Use with Leviton Power Pack or Power Base Adaptor Description Cat.. Coverage Color Ceiling Mount PIR Occupancy Sensor Ceiling Mount PIR Occupancy Sensor Ceiling Mount PIR Occupancy Sensor with Isolated Relay Ceiling Mount PIR Occupancy Sensor with Isolated Relay Power Base Adaptor OSC4-IW OSC15-IW OSC4-RIW OSC15-RIW 36, 45SF (41.8sm) 36, 15SF (139.35sm) 36, 45SF (41.8sm) 36, 15SF (139.35sm) Off-White White OPB15-DW Off-White Cosmetic Adaptor OPBCA-W Protective Cage for Ceiling Mount Sensors ODCCG- White te: Use low-voltage wiring to connect sensors to OSPXX Power Pack OPP2 or OSPxx Power Pack or OPB15 Power Base Adaptor. Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. OSC4-IW Sensing Control Low Voltage 12 5 5 12 8 2 1 1 2 8 12 9 7 5 3 3 5 7 9 12 2 15 11 9 5.6 3 3 5.6 9 11 15 2 OSC4-IW Field of View (in feet) OSC15-IW Field of View (in feet) Minor Motion, IR Major Motion, IR 16

CEILING MOUNT ULTRASONIC OCCUPANCY SENSORS Ceiling Mount Ultrasonic Occupancy Sensors and Accessories For Use with Leviton Power Pack or Power Base Adaptor Description Ceiling Mount Ultrasonic Occupancy Sensor Ceiling Mount Ultrasonic Occupancy Sensor Ceiling Mount Ultrasonic Occupancy Sensor Ceiling Mount Ultrasonic Occupancy Sensor with Isolated Relay Ceiling Mount Ultrasonic Occupancy Sensor with Isolated Relay Ceiling Mount Ultrasonic Occupancy Sensor with Isolated Relay Power Base Adaptor Cosmetic Adaptor Protective Cage for Ceiling-Mount Sensors Cat.. OSC5-UW OSC1-UW OSC2-UW OSC5-RUW OSC1-RUW OSC2-RUW OPB15-DW OPBCA-W ODCCG- Operating Frequency 4kHz 32kHz 4kHz 32kHz Coverage 18, 5SF (46.45SM) 36º, 1SF (92.9SM) 36, 2SF (185.81SM) 18º, 5SF (46.45SM) 36º, 1SF (92.9SM) 36º, 2SF (185.81SM) Color Off-White White Off-White te: Use low-voltage wiring to connect sensors to OPP2 or OSPxx Power Pack or OPB15 Power Base Adaptor Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. 8.5 8.5 8.5 81.5 White 16 16 OSC5-UW Sensing Control Low Voltage 5 1 2 17 23 23 17 17 23 32 22.5 22.5 32 OSC5-UW Field of View (in feet) OSC1-UW Field of View (in feet) OSC2-UW Field of View (in feet) Minor Motion, Ultrasonic Major Motion, Ultrasonic www.leviton.com/sensors 17

WALL MOUNT PIR OCCUPANCY SENSORS Sensing Control Low Voltage Infrared Indoor Wall-Mount Occupancy Sensors and Accessories For Use with Leviton Power Pack or Power Base Adaptor Description Cat.. Coverage Color Wide-View Wall Mount PIR Occupancy Sensor High-Bay Wall Mount PIR Occupancy Sensor Long-Range Wall Mount PIR Occupancy Sensor Wide-View Wall Mount PIR Occupancy Sensor with Isolated Relay High-Bay Wall Mount PIR Occupancy Sensor with Isolated Relay Long-Range Wall Mount PIR Occupancy Sensor with Isolated Relay Wall-Mount Multi- Occupancy Sensor Wall-Mount Multi- Occupancy Sensor with Isolated Relay Power Base Adaptor Cosmetic Adaptor Protective Cage for Ceiling-Mount Sensors OSWWW-IW OSWHB-IW OSWLR-IW OSWWV-RIW OSWHB-RIW OSWLR-RIW OSW12-MW OSW12-RMW OPB15-DW OPBCA-W OSWCG-PW 115, 25SF (232.26SM) 55 ft. x 7 ft. wide @ 1 ft. high (16.76m x 4.26m wide @ 3.4m high) 1 ft. x 14 ft. @ 1 ft. high (3.48m x 4.26m @ 3.4m high) 115, 25SF (232.26SM) 55 ft. x 7 ft. wide @ 3 ft. high (16.76m x 4.26m wide @ 9.14m high) 1 ft., 11º @ 1 ft. high (3.48m, @ 3.4m high) 115, 12SF (111.48SM) Off-White White Off-White White Off-White te: Use low-voltage wiring to connect sensors to OPP2 or OSPxx Power Pack or OPB15 Power Base Adaptor Leviton sensors meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings 3.5 3.5 White OSWHB-IW OSW12-MW Wall Mount 3 Minor Motion, IR Minor Motion, Ultrasonic Major Motion, IR Major Motion, Ultrasonic 58 58 3 13 25 52 OSWHB Field of View (in feet) 29 31 16 16.6 16 29 31 16.6 1 58 58 8 8 14 42 71 1 3 8 15 31 68 3 8 15 31 68 23 32 OSWLR Field of View (in feet) OSWWV Field of View (in feet) OSW12-MW Field of View (in feet) 18

POWER PACKS AND POWER BASE ADAPTOR COMMERCIAL GRADE OCCUPANCY SENSOR POWER PACKS Occupancy Sensor Power Packs Description Cat.. Power Input* Relay Rating Super Duty Power Pack with Auto-ON, Manual-ON, and Local Switch Inputs, CA Title 24 Super Duty Power Pack with Auto-ON and Photocell Input Super Duty Power Pack with Auto-ON, Manual-ON, Switch, and Photocell Input, CA Title 24 Power Pack with HVAC Relay withauto-on and Manual-ON Inputs for Occupancy Sensors Power Pack with HVAC Relay Add-A-Relay Unit with HVAC Relay OPP2-D2 OPP2-RD3 OPP2-RD4 ** OSP2-RDH OSP15-R3 OSA2-R 12-23-277VAC, 5/6 Hz 347VAC, 6Hz 2A, 24W @ 12V Resistive 2A, 24W @ 12V General Purpose 2A, 24W @ 12V Incandescent 2A, 24W @ 12V Fluorescent 2A, 554W @ 277V Resistive 2A, 554W @ 277V General Purpose 2A, 554VA @ 277V Fluorescent 16A, 443VA @ 277V Electronic Ballasts 1/2 HP @ 12V Motor Load 2 HP @ 24/277V Motor Load 2A Incandescent @ 12V, 2A Fluorescent @ 12-23- 277/347VAC; 1/2HP @ 12V, 2HP @ 24-277V; HVAC:.5A @ 12VAC, 1A @ 3VDC 15A fluorescent @ 347V; 1HP @ 12V, 2HP @ 24V; HVAC:.5A @ 12VAC, 1A @ 3VDC 15A incandescent @ 12V, HVAC:.5A @ 125VAC, 1A @ 3VDC Control Input 2mA, 24VDC 5mA, 24VDC *Consult with factory for 28, 22, and 24V models Leviton power packs meet the following applicable agency listings: UL, culus, ETL, CSA and NOM. See product data sheets for specific listings. **OPP2-RD4 is for general purpose plug load control - 2A, 24W @ 12V - complies with ASHRAE 9.1 and CA Title 24 Plug Load Control Requirements Pow Supply Output 225mA, 24VDC, 5.4W 225mA, 24VDC 12mA, 24VDC Sensing Control Power Packs OPP2 OSP2 www.leviton.com/sensors 19

POWER PACK CAPACITY FORMULA Leviton power packs can be used to provide power to one or more sensors. Since current consumptions of sensors may vary, the best way to ensure you order the correct number of power packs and Add-A-Relays is by using this formula: Sensor Current Consumption OSC4-I, OSC15-I, OSWHB-I, OSWLR-I, OSWWV-I 1-15mA OSC5-M, OSC5-U, OSW12-M 25mA OSC1-M, OSC1-U 35mA OSC2-M, OSC2-U 5mA OSA2-R Add-A-Relay 5mA Number of Model A sensors X Sensor A current consumption rating Number of Model B sensors + + X Sensor B current consumption rating Number of Add-A-Relays X 5mA < 225mA SELF-CONTAINED POWER BASE ADAPTOR Converts any Leviton low voltage ceiling or wall-mount occupancy sensor to a self-contained, line voltage unit with 15A, 12/277V load capacity. Sensing Control Power Packs Power Base Adaptor Description Cat.. Power Input/Output Rating Color Converts select Leviton low-voltage ceiling or wall mount occupancy sensor models to a self-contained line voltage unit OPB15-DW Power Input: 12-23-277VAC, 5/6Hz Control Input: 24VDC, 5mA Power Output: 12VAC @15A incandescent; 277VAC @ 15A fluorescent; Motor: 12VAC 3/4HP, 277VAC 2HP Control Output: 24VDC, 4mA Cosmetic Adaptor OPBCA-W Agency Listings & Code Compliance: NOM Certified. *Available in Off-White only. Consult with factory for 28, 22, 23 and 24V load ratings. te: Converts OSCxx-I, OSCxx-M and OSCxx-U. Does not convert OSCxx-R 15A Off-White OPB15-DW (Occupancy Sensor not included) 2

WIRELESS SENSORS Commercial Grade Specifications WSC12-M9N WSWDR-H9W Features Passive Infrared Mounting Ceiling Wall Coverage (SF) 12 Long Range: 16 SF Minor, 33 SF Major Wide Angle: 2 SF Minor, 396 SF Major Pattern 36 18 Mounting Height Up to 1 6-8 Adjustment Manual Time Delay 2m-3m Voltage Self-Powered, Energy Harvesting Wattage/VA Self-Powered, Energy Harvesting Occupancy or Vacancy Occupancy Auto or Manual Both - auto or manual selected in load receiver during pairing Ambient Light Override Other Mechanical Switching Neutral Required Ground Required Power Consumption (ma) Photocell HVAC Relay Environmental Operating Temperature/ Humidity Certifications CA Title 24 to 5 C/ 2 to 95% Energy Harvesting, Self-Powered, Wireless Up to 1 Relay - when paired with load receiver External Power t Required Self-Powered, Energy Harvesting t Applicable t Applicable to 5 C/ 2 to 95% Sensing Control Self-Powered www.leviton.com/sensors 21

WALL SWITCH Residential Grade Sensing Control Wall Switch Residential Specifications IPS2-1L IPV2-1L IPS5-1L IPV5-1L Features Passive Infrared Mounting Wall Coverage (SF) 9 Pattern 18 Mounting Height 4 Adjustment Manual Time Delay 3s-3m Voltage 12VAC, 6 Hz Wattage/VA 2VA 6W Occupancy or Vacancy Occupancy Vacancy Occupancy Vacancy Auto or Manual Auto Manual Auto Manual Ambient Light Override Other Single Pole Mechanical Switching Neutral Required Ground Required Power Pack Consumption Photocell HVAC Relay Environmental Operating Temperature/Humidity Certifications CA Title 2 CA Title 24 Relay External Power Pack t Required Internal t Applicable to 4 C/ 2 to 9% n-condensing Indoor Use Only 22

WALL SWITCH Residential Grade Specifications IPS6-1L IPSD6-1L IPVD6-1L IPS15-1L IPV15-1L IPHS5-W Features Passive Infrared Digital Sensor Mounting Wall Coverage (SF) 9 Pattern 18 Mounting Height 4 Adjustment Manual Time Delay 3s-3m 1m-45m Voltage 12VAC, 6 Hz Wattage/VA 18VA 6W Occupancy or Vacancy Occupancy Vacancy Occupancy Vacancy Occupancy Auto or Manual Auto Manual Auto Manual Auto Ambient Light Override Other Single Pole/3-Way Single Pole/3-Way with IPVOR Remote Sensor Single Pole Mechanical Switching Triac Relay Neutral Required Ground Required Power Pack External Power Pack t Required Power Pack t Required Consumption Photocell Internal ne HVAC Relay t Applicable Environmental Operating Temperature/ Humidity Certifications Listing CA Title 2 CA Title 24 to 4 C/ 2 to 9% n-condensing Indoor Use Only UL Sensing Control Wall Switch Residential www.leviton.com/sensors 23

WALL SWITCH Commercial Grade Sensing Control Wall Switch Commercial Specifications ODS6-ID ODS1-ID ODS1-I3 ODS1-IQ MDS1-ID Features Passive Infrared Mounting Wall Coverage (SF) 21 Pattern 6-18 Mounting Height 4 Adjustment Manual Time Delay 3s-3m Voltage 12-23-277 VAC 347 VAC 12-23-277 VAC Wattage/VA 8/15 347 18/4 Occupancy or Vacancy Occupancy Vacancy Occupancy Auto or Manual Both Auto Both Ambient Light Override Other Mechanical Switching Neutral Required Ground Required Power Pack Consumption Photocell HVAC Relay Environmental Operating Temperature/Humidity Photocell Certifications Single Pole, Multi-Location; Select Models Feature Auto-ON/Auto-OFF Only (ODS1-IQ), Self-Adaptive (MDS1, ODS15, MDS15, ODSD), or Lev-Lok (MDS1, MDS15) to 4 C/ to 95% n-condensing Indoor Use Only Relay External Power Pack t Required 1-25mW Internal t Applicable Internal to 5 C/ 2 to 9% n-condensing Indoor Use Only Listing UL cul UL CA Title 2 CA Title 24 24

WALL SWITCH Commercial Grade Specifications ODS15-ID ODS15-TD MDS15-ID ODSD-ID OSSNL-ID OSS1-IN Features Passive Infrared Mounting Wall Coverage (SF) 21 Pattern 6-18 Mounting Height 4 Adjustment Self-Adjusting Manual Time Delay 3s-2m or 5m-3m 3s-2h 3s-3m Voltage 12-23-277 VAC Wattage/VA 18/4 8/27 12/27 Occupancy or Vacancy Vacancy Occupancy Vacancy Auto or Manual Manual Both Manual Ambient Light Override Other Single Pole, Multi-Location; Select Models Feature Auto-ON/ Auto-OFF Only (ODS1-IQ), Self-Adaptive (MDS1, ODS15, MDS15, ODSD), or Lev-Lok (MDS1, MDS15) Single Pole, Multi-Location, Lev-Lok Dual Relay, Self-Adaptive Single Pole, Multi-Location, LED Night Light Mechanical Switching Relay Neutral Required Ground Required Power Pack External Power Pack t Required Consumption 12-28mW 11-27mW 19-41mW Photocell Internal ne HVAC Relay Environmental Operating Temperature/ Humidity to 4 C/ to 95% n-condensing Indoor Use Only t Applicable to 5 C/ 2 to 9% n-condensing Indoor Use Only Photocell Internal ne Certifications Listing UL CA Title 2 CA Title 24 Sensing Control Wall Switch Commercial www.leviton.com/sensors 25

WALL SWITCH Commercial Grade Sensing Control Wall Switch Commercial Specifications OSSMT-MD OSSMT-GD OSSMT-M3 OSSMT-MQ OSSMT-GQ OSSMT-TM Features Multi- Mounting Wall Coverage (SF) 24 Pattern 6-18 Mounting Height 4 Adjustment Self-Adjusting Time Delay 3s-3m Voltage 12-23-277 VAC 347 VAC 12-23-277 VAC Wattage/VA 8/27 12/27 Occupancy or Vacancy Occupancy Vacancy Auto or Manual Both Auto Manual Ambient Light Override Other Single Pole, Multi-Location; Select Models Feature Neutral (OSSMT-GT, OSSMT-GQ, MSSMT-GD, OSSMD-GD), Auto-ON/Auto-OFF Only (OSSMT-MQ, OSSMT-GQ), or Lev-Lok (MSSMT) Mechanical Switching Relay Neutral Required Ground Required Power Pack External Power Pack t Required Consumption 19-48mW 19-48mW 35-5mW 19-48mW 7-34mW 19-48mW Photocell Internal HVAC Relay t Applicable Environmental Operating Temperature/ Humidity Photocell Certifications to 4 C/ 2 to 9% n-condensing Indoor Use Only Internal Listing UL ETL CETL UL ETL UL CA Title 2 CA Title 24 26

WALL SWITCH Commercial Grade Specifications OSSMT-GT MSSMT-GD OSSMD-MD OSSMD-GD Features Multi- Mounting Wall Coverage (SF) 24 Pattern 6-18 Mounting Height 4 Adjustment Self-Adjusting Time Delay 3s-3m Voltage 12-23-277 VAC Wattage/VA 12/27 Primary Relay: 12/27, Secondary Relay: 8/12 Occupancy or Vacancy Vacancy Occupancy Auto or Manual Manual Both Ambient Light Override Other Single Pole, Multi-Location, Neutral Required, Lev-Lok (MSSMT) Single Pole, Multi-Location, Dual Relay, Neutral Required (OSSMD-GD) Mechanical Switching Relay Neutral Required Ground Required Power Pack External Power Pack t Required Consumption 7-34mW 21-41mW 14-36mW Photocell Internal HVAC Relay t Applicable Environmental Operating Temperature/ Humidity Photocell Certifications Listing CA Title 2 CA Title 24 to 4 C/ 2 to 9% n-condensing Indoor Use Only Internal ETL Sensing Control Wall Switch Commercial www.leviton.com/sensors 27

LINE VOLTAGE Commercial Grade Sensing Control Line Voltage Specifications ODC4-IDW ODC15-IDW O3C15-IDW O2C4-IDW O2C15-IDW O4C15-IDW Features Passive Infrared Mounting Ceiling Coverage (SF) 45; 15 15 45; 15 15 Pattern 36 Mounting Height 8-12 Adjustment Self Adjusting Time Delay 3s -3m Voltage 12-22/277 VAC, 5/6Hz Wattage/VA 8W/VA Occupancy or Vacancy Occupancy Vacancy Occupancy Vacancy Auto or Manual Both Manual Both Manual Ambient Light Override Other Open/Closed Loop Daylight Harvesting with Manual/AutoCal Configuration; Momentary or Maintained Manual Switch Input; BMS/Emergency Interface Momentary or Maintained Manual Switch Input; BMS/ Emergency Interface Dual Relay; Open/Closed Loop Daylight Harvesting with Manual/AutoCal Configuration; Momentary or Maintained Manual Switch Input; BMS/Emergency Interface Dual Relay; Momentary or Maintained Manual Switch Input; BMS/Emergency Interface Mechanical Switching Zero Cross Neutral Required Ground Required Power Pack t Required Consumption 6-3ma Photocell AutoCal Internal HVAC Relay t Applicable Environmental Operating Temperature/ Humidity Certifications Listing CA Title 2 CA Title 24 to 4 C/ to 9% n-condensing Indoor Use Only UL 28

LINE VOLTAGE Commercial Grade Specifications ODC5-UDW ODC1-UDW ODC2-UDW O2C5-UDW O2C1-UDW O2C2-UDW ODC5-MDW ODC1-MDW ODC2-MDW O3C1-MDW O3C2-MDW O2C5-MDW O2C1-MDW O2C2-MDW O4C1-MDW O4C2-MDW Features Ultrasonic Multi- Multi- Mounting Ceiling Coverage (SF) 5; 1; 2 1; 2 5; 1; 2 1; 2 Pattern 36 Mounting Height 8-12 Adjustment Self-Adjusting Time Delay 3s-3m Voltage 12-22/277 VAC, 5/6Hz Wattage/VA 8W/VA Occupancy or Vacancy Occupancy Vacancy Occupancy Vacancy Auto or Manual Both Manual Both Manual Ambient Light Override Other Open/Closed Loop Daylight Harvesting with Manual/AutoCal Configuration; Momentary or Maintained Manual Switch Input; BMS/Emergency Interface Momentary or Maintained Manual Switch Input; BMS/ Emergency Interface Dual Relay; Open/Closed Loop Daylight Harvesting with Manual/AutoCal Configuration; Momentary or Maintained Manual Switch Input; BMS/Emergency Interface Dual Relay; Momentary or Maintained Manual Switch Input; BMS/ Emergency Interface Mechanical Switching Zero Cross Neutral Required Ground Required Power Pack t Required Consumption 6-3mA Photocell AutoCal Internal HVAC Relay t Applicable Environmental Operating Temperature/ Humidity Certifications LIsting CA Title 2 CA Title 24 to 4 C/ to 9% n-condensing Indoor Use Only UL Sensing Control Line Voltage www.leviton.com/sensors 29

LINE VOLTAGE Commercial Grade Sensing Control Line Voltage Specifications ODCS-I1W ODCS-I2W ODWWV-IDW ODWHB-IDW ODWLR-IDW ODW12-MDW ODCS-I7W Features Passive Infrared Multi- Mounting Ceiling Wall, Corner or Ceiling Coverage (SF) 53 25 55x7 1 12 Pattern 36 8 11 @ 1ft high 11 Mounting Height 8-15 8-12 1-3 8-1 Adjustment Manual Time Delay 2s-15m Voltage 12-22/277 VAC; 6Hz; 5Hz; 6Hz Wattage/VA 1VA; 5VA; 27VA Occupancy or Vacancy Occupancy Vacancy Occupancy Auto or Manual Auto Manual Both Ambient Light Override Other Self- Contained Wide View, Includes Power Base High Bay, Includes Power Base Long Range, Includes Power Base Multi-Use, Includes Power Base Mechanical Switching Relay Zero Cross Relay Neutral Required Ground Required Power Pack t Required Consumption 4W 6-3ma.7W-2.34W Photocell Internal HVAC Relay Environmental Operating Temperature/ Humidity Certifications Listing CA Title 2 CA Title 24 t Applicable to 4 C/ to 95% n-condensing, Indoor Use Only UL 2-3 Lux Adjustable 3

LINE VOLTAGE Commercial Grade Specifications OSFHP OSFHD OSFHS OSF1-IW OSF1-IUW Features Passive Infrared Mounting Fixture Coverage (SF) 4-16 6x1 Pattern 36 & Aisle Ways 36 Mounting Height Up to 4 Up to 8 Adjustment Manual Time Delay 3s-3m Voltage 12-23-277-347/48 VAC, 5/6Hz 12-23-277-347V 5/6 Hz 12-277 VAC, 5/6Hz Wattage/VA 8W/VA Occupancy or Vacancy Occupancy Auto or Manual Auto Ambient Light Override Other Mechanical Switching Neutral Required Ground Required Power Pack Consumption Photocell HVAC Relay Environmental Operating Temperature/ Humidity Certifications Listing CA Title 2 CA Title 24 Includes 2 Lenses for High Bay & Low Bay; Select Models Feature Integrated Light Sensor, Alternating Relay, Dual Relay, Cold Storage and Triple Mount Options -1 to 71 C/ 2 to 9% n-condensing Indoor Use Only 2-3 Lux Adjustable Zero Cross t Required 6-3ma t Applicable UL to 71 C/ 1 to 9% n-condensing Indoor Use Only 38 Leads to 5 C/ 2 to 95% n-condensing Indoor Use Only Sensing Control Line Voltage www.leviton.com/sensors 31

LOW VOLTAGE Commercial Grade Sensing Control Low Voltage Specifications OSC4-IW OSC4-RIW OSC15-IW OSC15-RIW Features Passive Infrared Mounting Ceiling Coverage (SF) 45 15 Pattern 36 Mounting Height 8-1 8-12 or 12-2 8-1 8-12 or 12-2 Adjustment Self-Adjusting, Self-Calibrating Time Delay 3s-3m Voltage Use with OPP2 Power Pack Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays Occupancy or Vacancy Occupancy Auto or Manual Auto Ambient Light Override Other Low Profile, Custom White Color for Shaded Spaces, -R Models Feature Isolated Relay Mechanical Switching Relay Neutral Required Ground Required Power Pack 24VDC Required Consumption DC: 1mA AC: 3mA DC: 15mA DC: 1mA AC: 3mA DC: 15mA Photocell HVAC Relay Environmental Operating Temperature/ Humidity Certifications Listing CA Title 2 CA Title 2 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay ne Included to 4 C/ to 95% n-condensing Indoor Use Only UL 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay ne Included 32

LOW VOLTAGE Commercial Grade Specifications OSC5-UW OSC5-RUW OSC1-UW OSC1-RUW OSC2-UW OSC2-RUW Features Ultrasonic Mounting Ceiling Coverage (SF) 5 1 2 Pattern 18 36 Mounting Height 8-12 8-2 8-12 8-2 8-12 8-2 Adjustment Self-Adjusting, Self-Calibrating Time Delay 3s-3m Voltage Use with OPP2 Power Pack Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays Occupancy or Vacancy Occupancy Auto or Manual Auto Ambient Light Override Other Low Profile, Custom White Color for Shaded Spaces, -R Models Feature Isolated Relay Mechanical Switching Relay Neutral Required Ground Required Power Pack 24VDC Required Consumption Photocell HVAC Relay Environmental Operating Temperature/ Humidity Certifications UL CA Title 2 CA Title 24 25mA 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay AC: 45mA DC: 25mA ne Included 35mA 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay to 4 C/ % to 95% n-condensing Indoor Use Only AC: 5mA DC: 3mA ne Included 3mA 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay AC: 5mA DC: 3mA ne Included Sensing Control Low Voltage www.leviton.com/sensors 33

LOW VOLTAGE Commercial Grade Sensing Control Low Voltage Specifications OSC5-MW OSC5-RMW OSC1-MW OSC1-RMW OSC2-MW OSC2-RMW Features Multi- Mounting Ceiling Coverage (SF) 5 1 2 Pattern 18 36 Mounting Height 8-12 8-12 or 12-2 8-12 8-12 or 12-2 8-12 8-12 or 12-2 Adjustment Self-Adjusting, Self-Calibrating Time Delay 3s-3m Voltage Use with OPP2 Power Pack Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays Occupancy or Vacancy Occupancy Auto or Manual Auto Ambient Light Override Other Low Profile, Custom White Color for Shaded Spaces, -R Models Feature Isolated Relay Mechanical Switching Relay Neutral Required Ground Required Power Pack 24VDC Required Consumption Photocell HVAC Relay Environmental Operating Temperature/ Humidity Certifications Listing CA Title 2 CA Title 24 DC: 25mA 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay AC: 45mA DC: 25mA ne Included DC: 35mA 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay AC: 5mA DC: 3mA ne Included DC: 35mA 2-3 Lux Adjustable Use OSCxxx-RxW w/isolated Relay to 4 C/ % to 95% n-condensing, Indoor Use Only UL AC: 5mA DC: 3mA ne Included 34

LOW VOLTAGE Commercial Grade Specifications OSWWV-IW OSWWV-RIW OSWHB-IW OSWHB-RIW OSWLR-IW OSWLR-RIW OSW12-MW OSW12-RMW Features Passive Infrared Multi- Mounting Wall, Corner or Ceiling Coverage (SF) 25 55x7 1x33.2 12 Pattern 11 8 27-18 11 Mounting Height 8-1 1-3 8-1 Adjustment Self-Adjusting, Self-Calibrating Time Delay 3s-3m Voltage Use with OPP2 Power Pack Wattage/VA Unlimited Through Use of Power Packs and Add-A-Relays Occupancy or Vacancy Occupancy Auto or Manual Auto Ambient Light Override Other Mechanical Switching Neutral Required Ground Required Power Pack Consumption Wide View, -R Models Feature Isolated Relay DC: 15mA AC:3mA DC: 15mA High Bay, -R Models Feature Isolated Relay DC: 15mA Relay 24VDC Required AC:3mA DC: 15mA Long Range, -R Models Feature Isolated Relay DC: 15mA AC:3mA DC: 15mA Multi-Use, -R Models Feature Isolated Relay DC: 25mA AC: 45mA DC: 24mA Sensing Control Low Voltage Photocell 2-3 Lux Adjustable ne 2-3 Lux Adjustable ne 2-3 Lux Adjustable ne 2-3 Lux Adjustable ne HVAC Relay Use OSCxxx-RxW w/isolated Relay Included Use OSCxxx-RxW w/isolated Relay Included Use OSCxxx-RxW w/isolated Relay Included Use OSCxxx-RxW w/isolated Relay Included Environmental Operating Temperature/ Humidity to 4 C/ to 95% n-condensing Indoor Use Only Certifications Listing UL CA Title 2 CA Title 2 www.leviton.com/sensors 35

Leviton Manufacturing Co., Inc. Global Headquarters 21 N. Service Rd., Melville, NY 11747-3138 tech line 1-8-824-35 fax 1-8-832-9538 Leviton Manufacturing Co., Inc. Lighting & Energy Solutions 2497 SW Teton Avenue, Tualatin, OR 9762 tel 53-44-55 fax 53-44-5594 tech line (6:AM 4:PM PST Monday-Friday) 8-959-64 Visit our Website at: www.leviton.com/les G-7164L/D15-ak REV APR 215 facebook.com/leviton twitter.com/leviton youtube.com/levitonmfg 215 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice. USGBC and related logo is a trademark owned by the U.S. Green Building Council and is used by permission The American Recovery And Reinvestment Act of 29 ( ARRA ) provides federal grants and loans for projects throughout the country. Section 165 of the Act, named the Buy American provision, requires that certain materials and manufactured products used in projects funded by the Act be manufactured in the United States. The appearance of the Recovery Act Logo in relation to a Leviton product is only intended to reflect that such product may be used in an ARRA funded project. It does not mean that such product or Leviton is sponsored or endorsed by, or that Leviton receives funds from, the federal government or the Recovery Accountability and Transparency Board. thing in Leviton s use of the logo is intended to suggest anything regarding the requirements for funding under ARRA.