AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual

Similar documents
AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

AUTOTROL 360 MANUAL & 361 SEMI-AUTOMATIC FILTER VALVES SERVICE MANUAL

MP-MBA-45T-1/60T-1 / 75T-1

Autotrol Performa FA Valve

MASTER. Water Conditioning Corp. MP-TS-10T/20T with the 255/762 Logix Control Valve With Vortech. Installation and Operation Manual

Clean Water Made Easy. Fleck 7000 Tannin Filter Installation & Startup Guide. Questions?

Clean Water Made Easy

IMPORTANT SAFETY INFORMATION READ ALL...

5700-E Sediment Filter Installation & Start-Up Guide

7800 Neutralizer Installation & Start-Up Guide

RIVERSOFT Water Softener System

Autotrol Brand Performa Valve / 400 Series Controls

Clean Water Made Easy

Autotrol 255 Valve / 400 Series Controls

Autotrol Brand 255 Valve / 400 Series Controls

Fleck 5600 Carbon Filter Installation & Start Up Guide

Owner's Manual. Whole House Water Softener with Triton Electronic Control Valve. or call

Clean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?

WS1 Greensand Installation & Start Up Guide

Water Softener & Single Tank Triple Treat System Installation Overview. Using 1850 Metered Valves

Fleck 7000 Sediment Filter Installation & Start-Up Guide

7500-S Sediment Backwash Filter Guide

Installation Instructions & Owner's Manual. IM & INT Series

Pro Elite Professional Series Water Treatment System by GE. Operation Manual Pro Elite Analyzer

TITAN VI High Efficiency Water Conditioner Installation and Operation Manual

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter. EcoWater Systems Poland

CWS Plus Sediment Filter Installation & Start Up Guide

Clean Water Made Easy

Owner's Manual. WS Series. Water Softener

TITAN Pro-Max High Efficiency Upflow Water Conditioner Installation and Operation Manual

5900e Neutralizer Installation & Start Up Guide

Fleck 2510 Sediment Filter Installation & Start-Up Guide

1850 Series TRIPLE TREAT Operation Manual

FLECK XT OWNER S MANUAL

Fleck 2510 SXT Catalox Installation & Start Up Guide

Autotrol Performa Ultra. Electronic Control System Operation and Maintenance Manual

5900S Softener Installation & Start-Up Guide

High Flow 7000 SXT Water Softener

Clean Water Made Easy

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

Autotrol Performa Valve with 400 Series Control Water Conditioning Control System

5900S Arsenic Filter Operation & Maintenance Manual

7000 Meter Initiated Valve

6700XTR Valve Downflow

Installation & Service Manual

Installation, Operation and Maintenance Manual. Infusion Residential Water Softener 169-ISF-1C 169-ISF-2C 169-ISF-3C 169-ISF-4C

Water Softener Installation Guide Effective for all Softeners from our Range

6700 Valve Downflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #51431 Rev.

Econoflo SXT Automatic Meter Initiated Water Softener

GE & PROFILE SmartWater Softener Systems

Model NFF Iron, Manganese, Hydrogen Sulfide Reduction

High Flow 7000 SXT Series Water Softeners

INSTALLATION AND OPERATING INSTRUCTIONS

This material is intended only for Glass Water Systems customers. Reproduction or distribution of this material is strictly prohibited and protected.

Fleck 2510 Softener Installation & Start Up Guide

Care and Use Manual Tank Series Appliances

2020c WATER SOFTENER INSTALLATION INSTRUCTIONS. visit

5900e Greensand Filter Installation & Start-Up Guide

EVOLIO-560 Water Softener System

6700 Valve Upflow. Automatic Water Softeners Operation Manual. Read all instructions carefully before operation. #57341 Rev.

5900-BT Softener Installation & Start-Up Guide

ProFlo SXT Valve Downflow / Upflow

FLECK 5600 WATER SOFTENER INSTALLATION

Installation Instructions and Owner s Manual. HE, IM & INT Series. Water Softener System

6700XTR Upflow Valve. Water Softener Operation Manual. Read all instructions carefully before operation. #51548 Rev. 2/09

Whole House Filter Model: WH-LD

Model 7000SXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Autotrol Performa Valve

Autotrol Performa Valve

WS1 Softener Installation & Start-Up Guide

WATER SOFTENER WITH MICROPROCESSOR INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Water Softener Installation / Operation Manual

Evolve Series. Water Softeners and Conditioners. For Models: EV1 EV2 EVR EVRC EVRS EVRCS. For Cabinet Models: EVC EVCS

What to expect from your water softener

Series 255 Valve / 460i. Water Conditioning Control System Installation, Operation and Maintenance Manual

Birm 5900-BT Installation & Maintenance Guide

TotalCare, CareSoft Elite CareSoft Pro. and. Series. Water Softeners and Conditioners. For Models: TC1 TC2 CSE CSERC CSP CSPRC

Installation Instructions & Operating Manual. EM Series. Water Softener System

AUTOMATIC CARBON FILTER INSTALLATION & OPERATING INSTRUCTIONS

Model 7000SXT. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

FLECK 5800 SXT DOWNFLOW/UPFLOW SERVICE MANUAL

FLECK 3200 SERIES ELECTROMECHANICAL TIMER OWNER S MANUAL

Installation Instructions and Owner s Manual. PDIM Series. Water Softener System

Pro-Ox 5900S-AIR Installation & Start-Up Guide

PRF26K, PRF34K, and PRF40K Water Softening System. Manual de Sistema ablandador de agua. Manuel Adoucisseur d'eau

5900-BT Carbon Backwash Filter Installation & Maintenance Guide

Installation and Operation Manual

Record of System Specifications 2 Product Dimensions 3 Pre-Installation Checklist 4 System Installation 5-9 Installation Notice, Unit location,

Owner s Manual. Models: AWP-SE1 and AWP-SE2 Series Water Conditioners _RevG

Parts & Material Included

Tier1 Water Home Filtration System

Installation Instructions AS-WH Whole House Water Filter

OWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter

5900S Neutralizer Operation & Maintenance Manual

CMP & C METERED SERIES

HD / HDL Valves & Systems Service Manual

RevV4 Valves & Systems Service Manual. Innovative Solutions for Your Water

The Inlet and Outlet should be as per below illustration. This will ensure that water will flow through the filter in an upflow configuration

The WateRx Plant. Features/Benefits. Applications (for municipal water usage) Great water throughout the home or office. Automatic weekly backwash

Transcription:

AUTOTROL 363 DEMAND AUTOMATIC FILTER VALVE Service Manual 2014 Pentair Residential Filtration, LLC www.pentairaqua.com/pro

TABLE OF CONTENTS MANUAL OVERVIEW... 2 SAFETY INFORMATION... 2 TYPICAL TOOLS AND FITTINGS REQUIRED... 3 VALVE DIMENSIONS... 3 VALVE LAYOUT... 4 SPECIFICATIONS... 4 EQUIPMENT INSTALLATION... 4 SYSTEM STARTUP... 6 INSTALLATION CHECKLIST... 6 CONTROL OPERATION AND LAYOUT... 6 PROGRAMMING THE 606F DEMAND CONTROL... 7 REMOTE REGENERATION... 8 VALVE ASSEMBLY... 9 TROUBLESHOOTING... 10 FLOW DIAGRAMS... 11 FLOW PERFORMANCE DATA CHARTS... 12 MANUAL OVERVIEW How To Use This Manual This manual is designed to guide the installer through the process of installing and starting the filter. This manual is a reference and will not include every system installation situation. The person installing this equipment should have: Knowledge in water filter installation Basic plumbing skills Icons That Appear In This Manual WARNING: Failure to follow this instruction can result in personal injury or damage to the equipment. NOTE: This will make the process easier if followed. Inspection Inspect the unit for damage or missing parts. SAFETY INFORMATION Electrical There are no user-serviceable parts in the AC adapter, motor, or controller. In the event of a failure, these should be replaced. All electrical connections must be completed according to local codes. Use only the power AC adapter that is supplied. The power outlet must be grounded and always on. To disconnect power, unplug the AC adapter from its power source. Install an appropriate grounding strap across the inlet and outlet piping of the water system to ensure proper grounding is maintained. Mechanical Do not use petroleum-based lubricants such as petroleum jelly, oils, or hydrocarbon-based lubricants. Use only 100% silicone lubricants. All plastic connections should be hand tightened. Plumber tape should be used on connections that do not use an O-ring seal. Do not use pliers or pipe wrenches. All plumbing must be completed according to local codes. Soldering of the plumbing should be done before connecting to the valve. Excessive heat will cause interior damage to the valve. Observe local drain line requirements. Do not use lead-based solder for sweat solder connections. Do not support the weight of the system on the control valve fittings, plumbing, or the bypass. It is not recommended to use sealants on the threads. Use plumber tape (PTFE) on all threads. General Observe all warnings that appear in this manual. This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Keep the unit in the upright position. Do not turn on side, upside down, or drop. Turning the tank upside down will cause media to enter the valve. Operating ambient temperature is between 34 F (1 C) and 120 F (49 C). Operating water temperature is between 34 F (1 C) and 100 F (38 C). Working water pressure range is 20 to 125 psi (1.38 to 8.61 bar). Follow state and local codes for water testing. When filling media tank, do not open water valve completely. Fill tank slowly to prevent media from exiting the tank. Always make modifications to house plumbing first. Connect to valve last. Plastic parts and O-rings may be damaged by heat and solvents. When constructing plumbing connections, allow heated parts to cool and protect parts from solvents. Location Selection Location of a water treatment system is important. The following conditions are required: Level platform or floor. Constant electrical supply to operate the controller. Total minimum pipe run to water heater of ten feet (three meters) to prevent backup of hot water into system. Local drain or tub for discharge as close as possible. Water line connections with shutoff or bypass valves. Room to access equipment for maintenance. 2 Autotrol 363 Demand Automatic Filter Valve

SAFETY INFORMATION continued Outdoor Locations It is recommended that the equipment be installed indoors. When the water conditioning system must be installed outdoors, several items must be considered. Moisture The valve and controller are rated for NEMA 3 locations. Falling water should not affect performance. The system is not designed to withstand extreme humidity or water spray from below. Examples are: constant heavy mist, near corrosive environment, upwards spray from sprinkler. Direct Sunlight The materials used will fade or discolor over time in direct sunlight. The integrity of the materials will not degrade to cause system failures. Temperature Extreme hot or cold temperatures may cause damage to the valve or controller. Freezing temperatures will freeze the water in the valve. This will cause physical damage to the internal parts as well as the plumbing. Insects The controller and valve have been designed to keep all but the smallest insects out of the critical areas. TYPICAL TOOLS AND FITTINGS REQUIRED Pipe Cutter Tubing Cutter File Pliers Tape Measure Soldering Tools Lead Free Solder Bucket Towel Plumber Tape Adjustable Wrench Tube 100% Silicone Grease VALVE DIMENSIONS 7.75 (196.94 mm) 3.60 (91.56 mm) 4.22 (107.21 mm) 5.61 (142.37 mm) 4.00 (101.60 mm) 9.83 (249.57 mm) 5.18 (131.47 mm).75 (19.03 mm) Figure 1 Autotrol 363 Demand Automatic Filter Valve 3

B VALVE LAYOUT Outlet Inlet EQUIPMENT INSTALLATION If you are also installing a water softener, the softener should be installed downstream of this system. Grounding the Plumbing It is important that the plumbing system be electrically grounded. When a water treatment system is installed a nonmetallic bypass valve may interrupt the grounding. To maintain continuity, a grounding strap can be purchased at a hardware store. When it is installed the strap will connect the plumbing into the system to the plumbing leaving the system. Recycle Display Time Backwash Duration Water Line and Bypass Connection Once you have selected your location check the direction of the water flow in the main pipe. A bypass valve system should be installed on all water conditioning systems. The bypass valve system isolates the filter from the water supply and provides untreated water to service during routine maintenance and servicing procedures. Cleaning Cycle Interval/Days 2 Delayed Cleaning Cycle Indicator SPECIFICATIONS Flow Indicator Figure 2 Remove Cover Flow Rates (Valve Only) Service @ 15 psi...21 gpm (79 lpm) full flow Backwash @ 25 psi...19 gpm (72 lpm) full flow Fast Rinse @ 25 psi...5 gpm (19 lpm) Valve Connections Tank Thread...2-1/2 inches (63.5 mm) 8, male Inlet/Outlet Thread... 3/4 inch (19.05 mm) BSP, male... 3/4 inch (19.05 mm) NPT, male...1 inch (22.5 mm) BSP, male... 1 inch (22.5 mm) NPT, male...1-1/4 inch (31.75 mm) BSP, male...1-1/4 inch (31.75 mm) NPT, male...1-1/2 inch (38.1 mm) BSP, male...1-1/2 inch (38.1 mm) NPT, male Line...1 inch (22.5 mm) BSP, male... 1 inch (22.5 mm) NPT, male Distributor Tube Diameter... 1.050 inch (27 mm) Distributor Tube Length... Flush to top of tank ± 1/2 inch (13 mm) Design Specifications Valve Body...Glass-filled Noryl Rubber Components...Compounded for cold water Operating Pressure... 20-125 psi (1.38 8.61 bar) Water Temperature...34-100 F (1-38 C) Ambient Temperature*...34-120 F (1-49 C) * Recommended for indoor use only Line Flow Controls 1" (22.5 mm)...8-20 gpm (30-76 lpm). 3/4" (1.9 cm)...4-7 gpm (15-29 lpm) 4 Autotrol 363 Demand Automatic Filter Valve 1 3 Figure 3 Normal Operation Valves 1 and 3 open Valve 2 closed Bypassed Position Valve 2 open Valves 1 and 3 closed The valve connects to the water system by means of a connector assembly. The connector is secured to the plumbing and then inserted into the universal ports on the valve. A clip is used to hold it in place. Figure 4 Connector Assembly Before inserting the connector: Check that all O-rings are in place and not damaged. O-rings are pre-lubricated. Sliding surfaces should be lubricated with 100% silicone grease.

EQUIPMENT INSTALLATION continued Firmly insert connector into the valve body. Press locking clip into position. Make certain the clip is fully engaged. To remove a clip: 1. Turn off water and release water pressure at the valve. 2. Push the water line connectors into the valve body. This will help release O-rings that may have seated in place. 3. Remove the clip by inserting a flat blade under the top center of the clip and lifting (prying up) (Figure 4 Connector Assembly). WARNING: Do not use pliers to remove a clip. It is likely the clip will break. Line Flow Control The drain line flow control (DLFC) requires assembly (Figures 4 and 5). 1 Inch Line Flow Control Rates 8-20 GPM Line Connection NOTE: Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a system. 4. Use appropriate fittings to connect tubing to the DLFC connection on valve. 5. The drain line may be elevated up to 6 feet (1.8 m) providing the run does not exceed 15 feet (4.6 m) and water pressure at the filter is not less than 40 psi (2.76 bar). Elevation can increase by 2 feet (61 cm) for each additional 10 psi (.69 bar) of water pressure at the drain connector. 6. Where the drain line is elevated but empties into a drain below the level of the control valve, form a 7 inch (18 cm) loop at the far end of the line so that the bottom of the loop is level with the drain line connection. This will provide an adequate siphon trap. 7. Secure the discharge end of the drain line to prevent it from moving. Right Way Install washer with printed lettering facing the valve body. Figure 5-1" Line Flow Control 3/4 Inch Line Flow Control Rates 4-7 GPM 4002493 Rev A Install washer with printed lettering facing the valve body. 4002492 Rev A Figure 6-3/4" Line Flow Control Note: Install DLFC washer with printed lettering facing the valve body. Figure 7 Line Connection NOTE: Waste connections or drain outlet shall be designed and constructed to provide for connection to the sanitary waste system through an air gap of two pipe diameters or one inch (22 mm), whichever is larger. WARNING: Never insert drain line directly into a drain, sewer line, or trap (Figure 7 Line Connection). Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the filter. Electrical Connection WARNING: This valve and control are for dry location use only unless used with a Listed Class 2 power supply suitable for outdoor use. The 363 controller operates on 12-volt alternating current power supply. This requires use of the an AC adapter with your system. Make sure power source matches the rating printed on the AC adapter. Autotrol 363 Demand Automatic Filter Valve 5

SYSTEM STARTUP The system will now need to be placed into operation. Please review Manually Initiating A Cleaning Cycle on page 7 before attempting startup. 1. With the supply water for the system still turned off, position the bypass valve to the not in bypass (normal operation) position. 2. Press and hold the button on the controller for three seconds. This will initiate a manual cleaning cycle, and cycle the valve to the backwash position. 3. Filling the media tank with water: A. With the system in backwash, open the water supply valve very slowly to approximately the 1/4 open position. Water will begin to enter the media tank. Air will begin to be purged to drain as the media tank fills with water. WARNING: If opened too rapidly or too far, media may be lost out of the tank into the valve or the plumbing. In the 1/4 open position, you should hear air slowly escaping from the valve drain line. B. When all of the air has been purged from the media tank (water begins to flow steadily from the drain line), open the main supply valve all of the way. This will purge any remaining air from the tank. C. Allow water to run to drain until the water runs clear from the drain line. This purges any debris from the media bed. D. Turn off the water supply and let the system stand for about five minutes to allow any trapped air to escape from the media tank. Turn on the water supply after five minutes. Check for leaks. The system is now fully operational. INSTALLATION CHECKLIST Read the owner's/installation manual? Follow all safety guidelines in the manual? If metal pipe was used, did you restore the electrical ground? Securely install drain hose to an approved drain? Perform a leak test? Move the bypass valve to service? Start a cleaning cycle? CONTROL OPERATION AND LAYOUT Large LED Display A large two digit LED readout is highly visible in most installation settings. Simplified Three-Step Programming Only three buttons are required to fully program the control. Recycle Initiates either a delayed or immediate cleaning cycle. Time Displays or programs the time of day. Cleaning Cycle Interval Displays or programs the amount of water to treat between cleaning cycles. Backwash Duration Displays or programs the amount of time to elapse during the backwash cycle step. Flow Indicator The decimal point/flow indicator blinks on and off when water flow turns the meter. Power Loss Memory Retention The control features battery-free time of day retention during loss of power. The time will remain in memory. Note: All other programmed parameters are stored in the flash memory and are retained during power outages. Recycle Display Delayed Cleaning Cycle Indicator Time Figure 8 Flow Indicator Backwash Duration Cleaning Cycle Interval/Days Remove Cover 6 Autotrol 363 Demand Automatic Filter Valve

PROGRAMMING THE 606F DEMAND CONTROL Time of Day: Press to display the current time value in hours. The time value is displayed as a number from 0 to 23, with 0 representing midnight and 23 representing 11:00 PM. While the value is being displayed, press the button to increase the value. Press and hold the button to rapidly advance the value. Release the button when the desired value is displayed. The value will be stored in memory after five seconds. Range: 0-23 hours Note: The elapsed minutes will reset to zero when the hours are changed. Backwash Duration: Press to display the current backwash cycle step duration setting. The value in minutes will be displayed for five seconds. While the value is being displayed, press the button to increase the value. Press and hold the button to rapidly advance the value. Press and hold the button to rapidly advance the value. Release the button when the desired value is displayed. The value will be stored in memory after five seconds. Range: 2-50 minutes NOTE: The Rapid Rinse cycle step adjusts automatically based on the Backwash Duration value. See table below. Backwash Time Rinse Time 2-5 minutes 1 minute 6-9 minutes 2 minutes 10-13 minutes 3 minutes 14-17 minutes 4 minutes 18-21 minutes 5 minutes 22-25 minutes 6 minutes 26-29 minutes 7 minutes 30-35 minutes 8 minutes 36-40 minutes 9 minutes 41-50 minutes 10 minutes Cleaning Cycle Interval: Press to display the current cleaning cycle interval setting. The value in cubic meters (metric units) or hundreds of gallons (U.S. units) to treat between cleaning cycles will be displayed for five seconds. While the value is being displayed, press the button to increase the value. Press and hold the button to rapidly advance the value. Press and hold the button to rapidly advance the value. Release the button when the desired value is displayed. The value will be stored in memory after five seconds. Range:.4-9.5 cubic meters 100-4,000 gallons Default: 1.0 cubic meters 10 x100 (1,000) gallons Calendar Override: To set a time duration between cleaning cycles to ensure proper function of the filter in the event of a flow sensor malfunction, press and hold and for three seconds. The value in days between cleaning cycles will be displayed for five seconds. While the value is being displayed, press the button to increase the value. Press and hold the button to rapidly advance the value. Release the button when the desired value is displayed. The value will be stored in memory after five seconds. Range: 8 hours (0.3 days) - 30 days; 0 to disable Default: 0 (disabled) Accessing History Values The control features a review level that displays the operation history of the system. This is a great troubleshooting tool for the control valve. To access history values, press and simultaneously and hold for three seconds to view the diagnostic codes. NOTE: If a button is not pushed for 30 seconds the controller will exit the history values table. Press to advance through the table. When the desired diagnostic code is reached, Press to display the value. Some history values may have up to four digits. Press to display the first two digits of the value. Press to display the last two digits. Code Description H1 Days since last cleaning cycle H2 Current day of week (displayed as 0-6) H3 Water used today since 1:00 AM H4 Water used since last cleaning cycle A0 Average water usage for day 0 A1 Average water usage for day 1 A2 Average water usage for day 2 A3 Average water usage for day 3 A4 Average water usage for day 4 A5 Average water usage for day 5 A6 Average water usage for day 6 Manually Initiating A Cleaning Cycle Delayed Cleaning Cycle Press and release to program a delayed cleaning cycle. The system will regenerate at the next cleaning cycle time (1:00 AM). Repeat procedure to disable the scheduled cleaning cycle. The display indicator dot blinks when a delayed cleaning cycle is scheduled. Immediate Cleaning Cycle Press and hold the for three seconds to initiate an immediate cleaning cycle. The control cycles to the backwash cycle step. The control will proceed through a complete cleaning cycle. A cascading symbol (- -) will be displayed until the cycle is complete. Autotrol 363 Demand Automatic Filter Valve 7

PROGRAMMING THE 606F DEMAND CONTROL continued Quick Cycling The Control Quick Cycling Press and hold for three seconds to initiate an immediate cleaning cycle. The control will cycle to the backwash cycle step. 1. Press and release to display "C1" (backwash). 2. Simultaneously press then release and to move the control to the next cycle step, "C2" (rinse). NOTE: The time may be displayed for 5 seconds. 3. During a cycle step, press and release to toggle between "- -" and "C#". 4. Repeat steps 2 and 3 to cycle through each position. Quick Cycle to Service Position Simultaneously press and and hold for three seconds during any cleaning cycle step. The control will skip the remaining cycle steps and return to the service position. The time of day will be displayed when the control reaches the service position. AUXILIARY SWITCH An optional auxiliary switch kit (P/N 4002757) is available for the 363 demand valve to control an auxiliary switch when a cleaning cycle is initiated. 8 Autotrol 363 Demand Automatic Filter Valve

VALVE ASSEMBLY 14 12 11 15 10 16 8 4 1 9 2 17 3 7 5 6 13 4002436 Rev A Item No. QTY Part No. Description 1...1...4002555...Kit, Valve Discs, 360 Series Filter 2...1...4002211...Top Plate, 360 Series Filter 3...14...1234170...Screw, Pan Head, #8-18 x 9-16 LG 4...1...4002213...Spring, One Piece 5...1...4002212...Cam, 3 Cycle, 360 Series Filter 6...1...1000589...Cap, Pillow Block 7...1...Control Assemblies... 4002658...Control Assembly, 363/606F, North American... 4002659...Control Assembly, 363/606F, World 8...1...4001260...12 Volt Motor Assembly w/ Optical Sensor 9...1...4001889...Valve O-ring Kit 10...1...3022576...Transformer Cable 11...1...AC Wall Mount Adapters...1000811...North American Wall Trans - 115VAC...1000812...Australian Wall Trans - 240V...1000813...British Wall Trans - 240 V...1262524...Europe Cord Connect Trans - 240V...1000814...Europe Wall Trans - 240V...1000810...Japan Wall Trans - 100V 12...1... Line Flow Control... 4002459...Kit, DLFC, 4.0GPM, NPT, 360, Fltr... 4002460...Kit, DLFC, 4.5GPM, NPT, 360, Fltr... 4002461...Kit, DLFC, 5.0GPM, NPT, 360, Fltr... 4002462...Kit, DLFC, 6.0GPM, NPT, 360, Fltr... 4002463...Kit, DLFC, 7.0GPM, NPT, 360, Fltr... 4002464...Kit, DLFC, 8.0GPM, NPT, 360, Fltr... 4002465...Kit, DLFC, 9.0GPM, NPT, 360, Fltr... 4002466...Kit, DLFC, 10GPM, NPT, 360, Fltr... 4002467...Kit, DLFC, 12GPM, NPT, 360, Fltr... 4002468...Kit, DLFC, 15GPM, NPT, 360, Fltr Item No. QTY Part No. Description... 4002469...Kit, DLFC, 20GPM, NPT, 360, Fltr... 4002476...Kit, DLFC, 4.0GPM, BSP, 360, Fltr... 4002477...Kit, DLFC, 4.5GPM, BSP, 360, Fltr... 4002478...Kit, DLFC, 5.0GPM, BSP, 360, Fltr... 4002479...Kit, DLFC, 6.0GPM, BSP, 360, Fltr... 4002480...Kit, DLFC, 7.0GPM, BSP, 360, Fltr... 4002481...Kit, DLFC, 8.0GPM, BSP, 360, Fltr... 4002482...Kit, DLFC, 9.0GPM, BSP, 360, Fltr... 4002483...Kit, DLFC, 10GPM, BSP, 360, Fltr... 4002484...Kit, DLFC, 12GPM, BSP, 360, Fltr... 4002485...Kit, DLFC, 15GPM, BSP, 360, Fltr... 4002486...Kit, DLFC, 20GPM, BSP, 360, Fltr 13...1...4002757...Kit, Auxiliary Switch, 363 Filter 14...1... 1033444...Meter Assembly 15...1... 3027837...Meter Cable 16...2... 40576...Clip, H, Plastic, 7000 17...2...Kit, Connector (includes one connector and one O-ring)...42414-11...Connector, 3/4" BSP, Plastic...42414-01...Connector, 3/4" NPT, Plastic...61626...Connector, 3/4" & 1" Sweat...61561-10...Connector, 1" BSP, Brass...40563-11...Connector, 1" BSP, Plastic...61561...Connector, 1" NPT, Brass...40563-01...Connector, 1" NPT, Plastic...40565-11...Connector, 1-1/4" BSP, Plastic...40565-01...Connector, 1-1/4" NPT, Plastic...61562-10...Connector, 1-1/2" BSP, Brass...42241-11...Connector, 1-1/2" BSP, Plastic...61562...Connector, 1-1/2" NPT, Brass...42241-01...Connector, 1-1/2" NPT, Plastic...41242-01...Connector, 1" & 1-1/4", Sweat...41243-01...Connector, 1-1/4" & 1-1/2" Sweat Autotrol 363 Demand Automatic Filter Valve 9

TROUBLESHOOTING Control Error Codes Problem Possible Cause Solution E1 is displayed. Program settings have been corrupted. Press any key. Reprogram control. If E1 does not clear, replace control. E3 is displayed. Control does not detect the camshaft position and is returning to the service position. Camshaft is not turning during E3 display. Wait until the control returns to the service position. Check that motor is connected. Verify that the motor wire harness is connected to motor and controller module. Verify that optical sensor is connected and in place. Verify that motor gear has engaged the camshaft. If everything is connected, replace components in this order: 1. Motor Assembly, Optical Sensor Camshaft is turning more than five minutes to find Home position: 2. Control Verify that optical sensor is in place and connected to wire. Inspect for debris in the camshaft slots. If motor continues to rotate indefinitely, replace the following components in this order: 1. Motor Assembly, Optical Sensor 2. Control System Problem Possible Cause Solution Flowing or dripping water at drain after cleaning cycle. Control will not complete a cleaning cycle automatically. Backwashes or purges at excessively low or high rate. Flow indicator on control does not display service flow. Debris is preventing #3 or #4 valve disc from closing. Worn #3 or #4 valve disc. AC adapter or motor not connected. Debris is preventing camshaft from rotating. Defective motor. Meter clogged with debris. No drain line flow control. Restricted drain line. Bypass system in bypass position. Meter cable dislodged from valve. Meter clogged with debris. Remove debris. Replace valve discs. Connect power. Remove debris. Replace motor. Remove and clean meter. Install drain line flow control. Remove restriction. Remove bypass system from bypass. Fully insert meter cable into valve. Remove and clean meter. 10 Autotrol 363 Demand Automatic Filter Valve

FLOW DIAGRAMS SERVICE BACKWASH Untreated Water Treated Water Untreated Water Backwash Inlet 1 2 Inlet 1 2 Outlet 4 3 Outlet 4 3 Valve No. 1. Closed 2. Open 3. Closed 4. Closed Control Valve No. 1. Open 2. Closed 3. Open 4. Closed Media Tank Control Media Tank FAST RINSE Untreated Water Rinse Inlet 1 2 Outlet 4 3 Control Valve No. 1. Closed 2. Open 3. Closed 4. Open Media Tank Autotrol 363 Demand Automatic Filter Valve 11

FLOW PERFORMANCE DATA CHARTS 30 Service Cv = 5.43 25 PRESSURE DROP IN PSI 20 15 10 5 0 1 6 11 16 21 26 FLOW IN GPM BW Cv = 3.74 35 30 PRESSURE DROP IN PSI 25 20 15 10 5 0 1 6 11 16 21 FLOW IN GPM 12 Autotrol 363 Demand Automatic Filter Valve

For Autotrol Product Warranties visit: Autotrol para las garantías de los productos visite: Pour Autotrol garanties produit visitez le site : } www.pentairaqua.com/pro FILTRATION & PROCESS 5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209 P: 262.238.4400 www.pentairaqua.com 800.279.9404 F: 262.518.4404 tech-support@pentair.com All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. 4002752 Rev A FE14 2014 Pentair Residential Filtration, LLC All Rights Reserved.