Honeywell Air Sampling Devices Data Sheet

Similar documents
Honeywell Air Sampling Devices Data Sheet

Air Sampling Smoke Detection

Application Guide 001

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

ZXSe Range Data Sheet

Components Brochure DX CONNEXION

Extending Your Potential. Product Range

Product Overview Brochure. Flexibility to design a fire system that best suits you

HART XL High Sensitivity Smoke Detection

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Solution F2. Fire Alarm Control Panels one step ahead.

Aspirating Smoke Detection (ASD) Systems Fire Detection

High-precision aspirating smoke detectors for every requirement.

HART XL High Sensitivity Smoke Detection

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

FCS-320-TM Series Conventional Aspirating Smoke Detectors

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Fire control panel detect 3004 plus and accessories

v1.0.0 POWER SUPPLIES 2016

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

Analogue Addressable Fire Panel Range

Why Hart XL Aspirating Smoke Detection?

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

Loadstar AC/DC Systems

Interface Modules for SENTRI

Excel-EN Conventional Fire Control Panel

Combined CAN Sensor Unit Temperature, Humidity and Smoke

CAN unit for Analog Sensors

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Input/Output Modules Data Sheet

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Typical applications include the vibration detector. Detection of vibrations and shocks

Outdoor Temperature Sensor

Intelligent Single Loop Fire Alarm Control Panel

XC10 Extinguishing control panels

FAAST. Fire Alarm Aspirating Sensing Technology

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Air Sampling Smoke Detection System TITANUS MICRO SENS Rev.a

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

LASER ASPIRATED SMOKE DETECTOR

Saving lives, protecting valuables, securing process cycles Fire detection

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

AirFlow Sensor for Dry Contact connection

AL600ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

IGD.CO.UK

Intrusion Outdoor Protection Perimeter

MINERVA MZX125. Digital Addressable Fire Detection System

SUPREMATouch. Modular Fire & Gas Detection System

Quick Selection Guide Fire Systems LSN Periphery

An introduction to... Sigma

AL800ULADA. NAC Power Extender. Installation Guide

Opal TM AV Devices. Data Sheet. Benefits

On the job around the clock 24/7: Fire detection systems

C-Bus Four Channel Analogue Output Unit Installation Instructions

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

System 800 Addressable Fire Detection & Alarm System

MINERVA MZX125 Digital Addressable Fire Detection System

FCP 320/FCH 320 Conventional Automatic Fire Detectors

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Solution F1. Fire Control Panels the new generation

For Complete Fire and Gas Solutions

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

SUPREMATouch. Modular Fire & Gas Detection System

Open-area Smoke Imaging Detector. Engineering Specification

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Flexible Air-sampling Smoke Detection

MINERVA MX. 800 Series Ancillary Equipment

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

FAS-420 Aspirating Smoke Detector LSN "improved version" FAS-420. Operation Guide

FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R. Operation Guide

AnaLASER II Detector. Protection Systems. A UTC Fire & Security Company. High-Sensitivity Smoke Detector (HSSD ) FEATURES DESCRIPTION

Notifier by Honeywell: SMART Detection. SMART Detection. The Ultimate in False Alarm Technology...Make the SMART choice

EFBW series - BiWire Ultra control panel

Control Technologies Fze Ph: E: Sharjah, UAE. M: W:

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Organize your security with PSIM + software

Open-area Smoke Imaging Detection (OSID)

Organize your security with PSIM + software

Reflective Optical Beam Smoke Detector User Guide

Welcome to Morley IAS Fire Systems

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

TrueAlarm Analog Sensing

Series 65 Product Guide MAN 3036

FR-A180 FR-A360. Occupancy detector. Use

Smoke Vent Control Panel PCB4 V4 Installation Manual

LASER ASPIRATED SMOKE DETECTOR

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Conventional Fire Detection

5000 Series Rack Panels

Aspirated Smoke Detectors

Transcription:

Honeywell Air Sampling Devices Data Sheet Smoke detection with high sensitivity and false alarm immunity Product Overview Honeywell Air Sampling Devices (ASDs) are smoke detectors that actively take air samples from the monitored area and analyse them for the presence of smoke particles. They basically consist of a detection unit and the associated pipe system. The low pressure needed for air sampling is produced by a fan and airflow sensor technology ensures functionality by constantly monitoring the pipe system for breakages and obstructions. Thanks to their outstanding reliability, sensitivity and false alarm immunity, Honeywell air sampling smoke detection systems have been the tried and tested system of choice in a wide variety of applications. Especially in areas with particular detection requirements and difficult environmental conditions, these systems, approved under EN 54-20, have shown impressive technological leadership. Honeywell has demonstrated this through a comprehensive range of project design options for all the new standard classes and set a whole new standard within the industry.

Features Honeywell Hi-Spec ASD Developed to serve a wide range of applications with the highest specifications. 3-stage alarm system and a smoke level display in bar graph form Optional equipping of the device with a second detector module One air sampling device can monitor two separate monitored areas Double-knock detection EN 54-20 compliant Can replace up to 64 point-type smoke detectors Fan operates up to 560Pa Pipe length of up to 560m can be achieved fulfilling EN 54-20 Class A to C requirements Honeywell All-Spec ASD A universal air sampling device for a broad range of applications. A high degree of modularity makes it possible to achieve a cost-effective solution, customised to suit the specific needs of the customer. 1 to 3 alarm levels Optional equipping of the device with a second detector module One air sampling device can monitor two separate monitored areas Double-knock detection EN54-20 compliant Can replace up to 64 point-type smoke detectors Fan operates up to 560Pa Pipe length of up to 560m can be achieved fulfilling EN 54-20 Class A to C requirements Honeywell Compact ASD A cost-effective solution for monitoring small to medium-sized spaces and equipment. Optional ROOM IDENT Monitor up to 5 rooms/facilities Redundant fan The detector box option does not have its own fan and can be used in combination with Honeywell ASD systems to localise the sampling hole where the smoke is entering As a fixed system FSA is approved by DIBt Can be used to replace up to 8 point type smoke detectors Up to 50m of pipe length, regardless of whether Class A, B or C is required in accordance with EN 54-20 Applications Honeywell Hi-Spec ASD Honeywell All-Spec ASD Honeywell Compact ASD The complete Honeywell All-Spec and Hi-Spec ASDs offer a comprehensive product range along with accessories approved in accordance with EN 54-20. This allows the devices to be used in areas where other smoke detectors and air sampling smoke detection systems have long reached their limits. These include: IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers The compact Honeywell Compact ASD is ideal for applications where larger air sampling smoke detection systems would not be cost-effective or in situations that require individual room identification. Small to medium-sized spaces up to 400 m² (e.g. IT areas, server rooms) Equipment (e.g. switch cabinets, telecommunications equipment) Up to 5 adjacent rooms with localisation of the source of the fire (e.g. hotel rooms, offices, prison cells) Stand-alone areas of application (e.g. wind farms, transformer stations) Cold stores/freezers

Advantages Honeywell Hi-Spec ASD Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false alarm immunity through LOGIC SENS fire pattern recognition 3 alarm thresholds for a tiered alarm concept Smoke level display in bar graph form A broad range of accessories, approved to EN 54-20 High degree of modularity for a customised, cost effective solution Reliable project design with just 5 mouse clicks Time saving commissioning through Plug & Play Double-knock detection to enable separate room and equipment monitoring Honeywell All-Spec ASD Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false alarm immunity through LOGIC SENS fire pattern recognition Up to 3 alarm thresholds for a tiered alarm concept A broad range of accessories, approved to EN 54-20 High degree of modularity for a customised, cost effective solution Reliable project design with just 5 mouse clicks Time saving commissioning through Plug & Play Double-knock detection to enable separate room and equipment monitoring Honeywell Compact ASD Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false alarm immunity through LOGIC SENS fire pattern recognition Optional individual room detection of the source of the fire with ROOM IDENT 1 to 2 alarm thresholds Smoke level display in bar graph form with Compact2 Time saving commissioning through Plug & Play Also available without fan as detector box Optional with redundant fan Electrical Hi-Spec All-Spec Compact Operating Voltage 24 V DC (14-30 V DC) 24 V DC (14-30 V DC) 24 V DC (16-30 V DC) Max. Quiescent Current 200 (210) 220 (240) 200 ma (4) 230 ma (4) 105 ma (4) (at 24 V DC) ma (1) and (4) ma (1) and (4) Max Alarm Current 210 (220) 240 250 230 ma 290 ma 110-140 ma (1) (at 24 V DC) (4) ma (1) ma (1) Starting Current Limited to 300 (390) 320 (400) 300mA 330mA 150mA ma ma Mechanical Hi-Spec All-Spec Compact Dimensions (W x H x D) 200 x 292 x 113mm 200 x 292 x 113mm 140 x 222 x 70mm Weight 1460g 1560g 1460g 1560g 850 to 895g (3) Protection Category IP 20 (Optional IP 52) IP 20 (Optional IP 52) up to IP 54 Temperature Range -20 C to + 60 C -20 C to + 60 C -20 C to + 60 C Cold Storage Option -40 C to + 60 C -40 C to + 60 C -40 C to + 60 C Humidity 10 % to 95 % relative 10 % to 95 % relative 10 % to 95 % (Permanent) humidity humidity relative humidity

Sensitivity Hi-Spec All-Spec Compact Sensitivity Detector Module Info-alarm: 0.17% LT/m (1) ASD-TT-05 (Sampling holes in Pre-alarm: 0.3% LT/m (1) accordance with EN54-20: Main alarm: 0.5% LT/m Class A max 2x32, Class B max 2x32, Class C max 2x32) Sensitivity Detector Module Info-alarm: 0.03% LT/m (1) ASD-TT-01 (Sampling holes in Pre-alarm: 0.07% LT/m (1) Main alarm: 0.1% LT/m Class A max. 2 x 9, Class B max. 2 x 32, Class C max. 2 x 32 Sensitivity Detector Module Info-alarm: 0.005% LT/m (1) ASD-TT-001 (Sampling holes in Pre-alarm: 0.010% LT/m (1) Main alarm: 0.015% LT/m Class A max. 2 x 4, Class B max. 2 x 12, Class C max. 2 x 32) Sensitivity Detector Module ASD-TP-05 (Sampling holes in Class A max. 2 x 32, Class B max. 2 x 32, Class C max. 2 x 32) Sensitivity Detector Module ASD-TP-01 (Sampling holes in Class A max. 2 x 9, Class B max. 2 x 32, Class C max. 2 x 32) Sensitivity Detector Module ASD-TP-001 (Sampling holes in Class A max. 2 x 4, Class B max. 2 x 12, Class C max. 2 x 32) Sensitivity Detection Module (Sampling holes in accordance with EN 54-20: Class A max. 2, Class B max. 6, Category C max. 8) Main alarm: 0.015% LT/m Main alarm: 0.1% LT/m Main alarm: 0.5% LT/m Pre-alarm (1) : 0.25% LT/m Main alarm: 0.50% LT/m Notes (1) Depending on type of device (2) Depending on project design (3) Depending on device configuration (4) At standard fan voltage of 6.9 V (5) Including ROOM IDENT

Technical Hi-Spec All-Spec Compact No. of Detector Modules 1 2 1 2 1 or 2 (5) Max Number of Sampling Holes 32 64 32 64 8 Max Pipe Length 300m 560m 300m 560m 50m (with max number of sampling holes) Localisation Using ROOM IDENT Monitoring of up to 5 rooms with localisation of the source of the fire (3) Monitored Area per Sampling Hole Corresponds to one point-type detector in accordance with VDE 0833-2 Monitoring of Pipe Systems Optional adjustment for individual hole monitoring (2) for Breakage and Obstruction Double-knock Detection Possible using Yes Possible using Yes Possible using detector box (Separate detector box (Separate detector box room and room and equipment equipment protection) protection) Alarms (potential free Up to 3 alarms per detector 3 alarms per detector change-over contacts) module (info-alarm, pre- module (info-alarm, prealarm and main alarm) alarm and main alarm) Alarm Notification 1-2 (Pre and main alarm) (3) Volt Free Contacts, 3 3 2 (5) Internal (External Optional) Fault Alarms Common alarm (1 volt-free Common Alarm (1 potential Cumulative report (Potential contact per detector module, free contact per detector free contact, either via NC NC or NO) module, NC or NO) or NO) Alarm and Fault Relay 1 A, 30 V DC, max. 24 W 1 A, 30 V DC, max. 24 W 1 A, 30 V DC, max. 24 W Power Rating Clamped Connections Max. 1.5 mm 2 Max. 1.5mm 2 Max 2.5mm 2 Displays on the Device: Pre-Alarm (Types TP-4, TP-5) 1 red alarm indicator per 1 red alarm 1 red alarm indicator per detector module display for each (3) detector module (1) Main Alarm (Types TP-1/a, TP-3, TP-4, 1 red alarm indicator 1 red alarm display for each TP-5) 1 red alarm indicator per detector module per detector module Info Alarm (Type TP-5) 1 red alarm 1 red alarm indicator indicator per detector per detector module module Smoke Level 10-step bar graph display 10-step bar graph display (3) Fault Yellow collective fault Yellow collective fault Yellow common fault Operation Green operation display Green operation display Green operation display Event Log Built-in, additional external Built-in, additional external Built-in data storage possible data storage possible Connection of External Parallel display optional Parallel display optional Parallel displays and Alarm Notifications ROOM IDENT indicators optional Redundant Fan Built in (3) Approved in Accordance with EN 54-20 Classes A, B, C: VdS-No. G 202064 G 202064 G 206004 BPRI-No. 0786-CPD-20685 0786-CPD-20685 0786-CPD-20322

Approved EN54-4 Power Supply Units This new range of power supplies has been specifi cally designed for Fire System Installations and features high effi ciency switch mode operation, intelligent battery charging and monitoring with remote fault signalling. Fully compliant with EN54-4:1997 + A1:2002 & A2:2006. VdS certifi cate No: G209142 Features Full Rated Current to Load + Additional current for battery charging Electronic Overload Protection LED Indication - Mains Status - Output Fault - Battery Fault - Charger Fault Volt Free Fault Output - EPS - Mains Fail Volt Free Fault Output PSU Fault - Battery Fault - Charger Fault - Loss of Output Mains Transient Protection 2A & 5A models can house and charge 2x 18Ah batteries 5A model can charge up to 2 x 38Ah Batteries housed in separate Battery Box, complete with leads, available on request.

Technical Height Width Depth Output (mains on) Load Output Max Battery Supply (Batteries not supplied) 2A, 5A 5A Mains Supply Environment Enclosure All Models Battery Box 420 mm 400 mm 180 mm 26.0-28.0V dc nominal 2.0, 5.0 Amp 2x17Ah in own enclosure Up to 2x38Ah in separate Battery Box 93V ac to 264V ac @50/60Hz -10C to 40C @95%RH 420h x 400w x 80d hinge lid 420h x 420w x 180d hinge lid 420 mm 400 mm 180 mm

Part Numbers Panels ASD-CM Honeywell Compact ASD (Including Detector) 0.5% obscuration ASD-CM2 Honeywell Compact2 ASD (Including 2 Detectors and ROOM IDENT) ALL-SPEC1 Honeywell ALL-SPEC1 ASD ALL-SPEC2 Honeywell ALL-SPEC2 ASD ASD-TP-01 Smoke Detectors for Honeywell ALL-SPEC ASD 0.1% obscuration ASD-TP-05 Smoke Detectors for Honeywell ALL-SPEC ASD 0.5% obscuration ASD-TP-001 Smoke Detectors for Honeywell ALL-SPEC ASD 0.015% obscuration HI-SPEC1 Honeywell HI-SPEC1 ASD HI-SPEC2 Honeywell HI-SPEC2 ASD ASD-TT-01 Smoke Detectors for Honeywell Hi-SPEC ASD 0.1% obscuration ASD-TT-05 Smoke Detectors for Honeywell Hi-SPEC ASD 0.5% obscuration ASD-TT-001 Smoke Detectors for Honeywell Hi-SPEC2 ASD 0.015% obscuration A silent and freezer version is also available. Please contact your local business manager for further information. For further details on these or any other Morley-IAS products please contact your local distributor, Morley-IAS Business Manager or via our contact details found below. Morley-IAS by Honeywell - Providing a control panel solution, for fire industry professionals, committed to supporting our device partners. Every care has been taken in the preparation of this datasheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. Morley-IAS by Honeywell 2011 Caburn House, 2B Brooks Road Lewes, E.Sussex BN7 2BY, UK T: +44 (0) 1444 235 556 F: +44 (0) 1273 376 894 E: sales@morleyias.co.uk www.morley-ias.co.uk DOC REF: M300-ASD(0811)