Honeywell Air Sampling Devices Data Sheet

Similar documents
Honeywell Air Sampling Devices Data Sheet

Air Sampling Smoke Detection

Application Guide 001

ZXSe Range Data Sheet

Extending Your Potential. Product Range

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Analogue Addressable Fire Panel Range

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Product Overview Brochure. Flexibility to design a fire system that best suits you

Aspirating Smoke Detection (ASD) Systems Fire Detection

Components Brochure DX CONNEXION

High-precision aspirating smoke detectors for every requirement.

High-precision aspirating smoke detectors for every requirement SecuriRAS ASD 535, ASD 532 and ASD 531 aspirating smoke detectors

Input/Output Modules Data Sheet

FCS-320-TM Series Conventional Aspirating Smoke Detectors

HART XL High Sensitivity Smoke Detection

ID2000. intelligent fire alarm panel

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

CAN unit for Analog Sensors

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Combined CAN Sensor Unit Temperature, Humidity and Smoke

ID3000 intelligent. fire alarm panel

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

HART XL High Sensitivity Smoke Detection

Typical applications include the vibration detector. Detection of vibrations and shocks

Solution F2. Fire Alarm Control Panels one step ahead.

Outdoor Temperature Sensor

FAAST. Fire Alarm Aspirating Sensing Technology

Notifier by Honeywell: FAAST TM Fire Alarm Aspiration Sensing Technology

Saving lives, protecting valuables, securing process cycles Fire detection

Air Sampling Smoke Detection System TITANUS MICRO SENS Rev.a

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

GE Lighting. Lighting Controls. DALI Digital Lighting Controls

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

ID3000 intelligent. fire alarm panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Interface Modules for SENTRI

FCP 320/FCH 320 Conventional Automatic Fire Detectors

intelligent fire alarm ID60series panels

AirFlow Sensor for Dry Contact connection

Welcome to Morley IAS Fire Systems

ID50series. intelligent fire alarm panels

FAS-420 Aspirating Smoke Detector LSN "improved version" FAS-420. Operation Guide

CerberusTM. PRO intelligent protection. A comprehensive fire protection system. Answers for infrastructure.

FCS-320-TM Aspirating Smoke Detector FCS-320-TM FCS-320-TM-R. Operation Guide

Quick Selection Guide Fire Systems LSN Periphery

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Fire control panel detect 3004 plus and accessories

Why Hart XL Aspirating Smoke Detection?

Flexible Air-sampling Smoke Detection

XC10 Extinguishing control panels

TrueAlarm Analog Sensing

A Comparison of Aspirated Smoke Detectors

FR-A180 FR-A360. Occupancy detector. Use

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

FAS-420-TM Aspirating Smoke Detector FAS-420-TM. Operation Guide

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

SUPREMATouch. Modular Fire & Gas Detection System

LASER ASPIRATED SMOKE DETECTOR

Cerberus PRO intelligent fire protection. A comprehensive portfolio of innovative and industry-leading technology.

Analogue Addressable Fire Panel Range

FDA241, FDA221 Siemens ASD

Aspiration Systems for Smoke Detection

FDA241, FDA221 Siemens ASD

SUPREMATouch. Modular Fire & Gas Detection System

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

FAAST. Fire Alarm Aspirating Sensing Technology

MINERVA MZX125 Digital Addressable Fire Detection System

Loadstar AC/DC Systems

Aspirated Smoke Detectors

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

FAAST PRODUCT RANGE Aspirating Smoke Detection

Control Technologies Fze Ph: E: Sharjah, UAE. M: W:

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

DT1101A / DT1102A / DO110xA Automatic fire detectors

EnvironmentalMonitoring

For Complete Fire and Gas Solutions

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

Open-area Smoke Imaging Detector. Engineering Specification

Reflective Optical Beam Smoke Detector User Guide

MINERVA MZX125. Digital Addressable Fire Detection System

Building Integration System. Your platform for customized security and safety management.

Open-area Smoke Imaging Detection (OSID)

GAS EXTINGUISHING SYSTEMS COMPACT EXTINGUISHING SYSTEMS. OneU. Fire Protection Systems for 19" Racks

Silent Knight Software Suite Intelliknight Training

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Intrusion Outdoor Protection Perimeter

Solution F1. Fire Control Panels the new generation

I N T E L L I G E N T A S P I R A T I N G. Intelligent Aspirating Fire Detector. Intelligent Earliest Warning Aspirating Fire Detector

Interface and EOL Modules 8

On the job around the clock 24/7: Fire detection systems

Organize your security with PSIM + software

OH110, OP110, HI110 Automatic fire detectors

Organize your security with PSIM + software

Transcription:

Honeywell Air Sampling Devices Data Sheet Smoke detection with high sensitivity and false alarm immunity Product Overview Honeywell Air Sampling Devices (ASDs) are smoke detectors that actively take air samples from the monitored area and analyse them for the presence of smoke particles. They basically consist of a detection unit and the associated pipe system. The low pressure needed for air sampling is produced by a fan and airflow sensor technology ensures functionality by constantly monitoring the pipe system for breakages and obstructions. Thanks to their outstanding reliability, sensitivity and false alarm immunity, Honeywell air sampling smoke detection systems have been the tried and tested system of choice in a wide variety of applications. Especially in areas with particular detection requirements and difficult environmental conditions, these systems, approved under EN 54-20, have shown impressive technological leadership. Honeywell has demonstrated this through a comprehensive range of project design options for all the new standard classes and set a whole new standard within the industry.

Features Honeywell Hi-Spec ASD Developed to serve a wide range of applications with the highest specifications. 3-stage alarm system and a smoke level display in bar graph form Optional equipping of the device with a second detector module One air sampling device can monitor two separate monitored areas Double-knock detection EN 54-20 compliant Can replace up to 64 point-type smoke detectors Fan operates up to 560Pa Pipe length of up to 560m can be achieved fulfilling EN 54-20 Class A to C requirements Honeywell All-Spec ASD A universal air sampling device for a broad range of applications. A high degree of modularity makes it possible to achieve a cost-effective solution, customised to suit the specific needs of the customer. 1 to 3 alarm levels Optional equipping of the device with a second detector module One air sampling device can monitor two separate monitored areas Double-knock detection EN54-20 compliant Can replace up to 64 point-type smoke detectors Fan operates up to 560Pa Pipe length of up to 560m can be achieved fulfilling EN 54-20 Class A to C requirements Honeywell Compact ASD A cost-effective solution for monitoring small to medium-sized spaces and equipment. Optional ROOM IDENT Monitor up to 5 rooms/facilities Redundant fan The detector box option does not have its own fan and can be used in combination with Honeywell ASD systems to localise the sampling hole where the smoke is entering As a fixed system FSA is approved by DIBt Can be used to replace up to 8 point type smoke detectors Up to 50m of pipe length, regardless of whether Class A, B or C is required in accordance with EN 54-20 Applications Honeywell Hi-Spec ASD Honeywell All-Spec ASD Honeywell Compact ASD The complete Honeywell All-Spec and Hi-Spec ASDs offer a comprehensive product range along with accessories approved in accordance with EN 54-20. This allows the devices to be used in areas where other smoke detectors and air sampling smoke detection systems have long reached their limits. These include: IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers IT areas and clean rooms General warehouses High bay storage areas Production and assembly lines Wind farms Libraries, museums and archives Hospitals, hotel rooms and saunas Recycling areas Rail vehicles and tunnels Cold stores/freezers The compact Honeywell Compact ASD is ideal for applications where larger air sampling smoke detection systems would not be cost-effective or in situations that require individual room identification. Small to medium-sized spaces up to 400 m² (e.g. IT areas, server rooms) Equipment (e.g. switch cabinets, telecommunications equipment) Up to 5 adjacent rooms with localisation of the source of the fire (e.g. hotel rooms, offices, prison cells) Stand-alone areas of application (e.g. wind farms, transformer stations) Cold stores/freezers

Sensitivity Hi-Spec All-Spec Compact Sensitivity Detector Module Info-alarm: 0.17% LT/m (1) ASD-TT-05 (Sampling holes in Pre-alarm: 0.3% LT/m (1) accordance with EN54-20: Main alarm: 0.5% LT/m Class A max 2x32, Class B max 2x32, Class C max 2x32) Sensitivity Detector Module Info-alarm: 0.03% LT/m (1) ASD-TT-01 (Sampling holes in Pre-alarm: 0.07% LT/m (1) Main alarm: 0.1% LT/m Class A max. 2 x 9, Class B max. 2 x 32, Class C max. 2 x 32 Sensitivity Detector Module Info-alarm: 0.005% LT/m (1) ASD-TT-001 (Sampling holes in Pre-alarm: 0.010% LT/m (1) Main alarm: 0.015% LT/m Class A max. 2 x 4, Class B max. 2 x 12, Class C max. 2 x 32) Sensitivity Detector Module ASD-TP-05 (Sampling holes in Class A max. 2 x 32, Class B max. 2 x 32, Class C max. 2 x 32) Sensitivity Detector Module ASD-TP-01 (Sampling holes in Class A max. 2 x 9, Class B max. 2 x 32, Class C max. 2 x 32) Sensitivity Detector Module ASD-TP-001 (Sampling holes in Class A max. 2 x 4, Class B max. 2 x 12, Class C max. 2 x 32) Sensitivity Detection Module (Sampling holes in accordance with EN 54-20: Class A max. 2, Class B max. 6, Category C max. 8) Main alarm: 0.015% LT/m Main alarm: 0.1% LT/m Main alarm: 0.5% LT/m Pre-alarm (1) : 0.25% LT/m Main alarm: 0.50% LT/m Notes (1) Depending on type of device (2) Depending on project design (3) Depending on device configuration (4) At standard fan voltage of 6.9 V (5) Including ROOM IDENT

Technical Hi-Spec All-Spec Compact No. of Detector Modules 1 2 1 2 1 or 2 (5) Max Number of Sampling Holes 32 64 32 64 8 Max Pipe Length 300m 560m 300m 560m 50m (with max number of sampling holes) Localisation Using ROOM IDENT Monitoring of up to 5 rooms with localisation of the source of the fire (3) Monitored Area per Sampling Hole Corresponds to one point-type detector in accordance with VDE 0833-2 Monitoring of Pipe Systems Optional adjustment for individual hole monitoring (2) for Breakage and Obstruction Double-knock Detection Possible using Yes Possible using Yes Possible using detector box (Separate detector box (Separate detector box room and room and equipment equipment protection) protection) Alarms (potential free Up to 3 alarms per detector 3 alarms per detector change-over contacts) module (info-alarm, pre- module (info-alarm, prealarm and main alarm) alarm and main alarm) Alarm Notification 1-2 (Pre and main alarm) (3) Volt Free Contacts, 3 3 2 (5) Internal (External Optional) Fault Alarms Common alarm (1 volt-free Common Alarm (1 potential Cumulative report (Potential contact per detector module, free contact per detector free contact, either via NC NC or NO) module, NC or NO) or NO) Alarm and Fault Relay 1 A, 30 V DC, max. 24 W 1 A, 30 V DC, max. 24 W 1 A, 30 V DC, max. 24 W Power Rating Clamped Connections Max. 1.5 mm 2 Max. 1.5mm 2 Max 2.5mm 2 Displays on the Device: Pre-Alarm (Types TP-4, TP-5) 1 red alarm indicator per 1 red alarm 1 red alarm indicator per detector module display for each (3) detector module (1) Main Alarm (Types TP-1/a, TP-3, TP-4, 1 red alarm indicator 1 red alarm display for each TP-5) 1 red alarm indicator per detector module per detector module Info Alarm (Type TP-5) 1 red alarm 1 red alarm indicator indicator per detector per detector module module Smoke Level 10-step bar graph display 10-step bar graph display (3) Fault Yellow collective fault Yellow collective fault Yellow common fault Operation Green operation display Green operation display Green operation display Event Log Built-in, additional external Built-in, additional external Built-in data storage possible data storage possible Connection of External Parallel display optional Parallel display optional Parallel displays and Alarm Notifications ROOM IDENT indicators optional Redundant Fan Built in (3) Approved in Accordance with EN 54-20 Classes A, B, C: VdS-No. G 202064 G 202064 G 206004 BPRI-No. 0786-CPD-20685 0786-CPD-20685 0786-CPD-20322

Advantages Honeywell Hi-Spec ASD Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false alarm immunity through LOGIC SENS fire pattern recognition 3 alarm thresholds for a tiered alarm concept Smoke level display in bar graph form A broad range of accessories, approved to EN 54-20 High degree of modularity for a customised, cost effective solution Reliable project design with just 5 mouse clicks Time saving commissioning through Plug & Play Double-knock detection to enable separate room and equipment monitoring Honeywell All-Spec ASD Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false alarm immunity through LOGIC SENS fire pattern recognition Up to 3 alarm thresholds for a tiered alarm concept A broad range of accessories, approved to EN 54-20 High degree of modularity for a customised, cost effective solution Reliable project design with just 5 mouse clicks Time saving commissioning through Plug & Play Double-knock detection to enable separate room and equipment monitoring Honeywell Compact ASD Early fire detection thanks to innovative, highly sensitive HPLS light source technology High degree of false alarm immunity through LOGIC SENS fire pattern recognition Optional individual room detection of the source of the fire with ROOM IDENT 1 to 2 alarm thresholds Smoke level display in bar graph form with Compact2 Time saving commissioning through Plug & Play Also available without fan as detector box Optional with redundant fan Electrical Hi-Spec All-Spec Compact Operating Voltage 24 V DC (14-30 V DC) 24 V DC (14-30 V DC) 24 V DC (16-30 V DC) Max. Quiescent Current 200 (210) 220 (240) 200 ma (4) 230 ma (4) 105 ma (4) (at 24 V DC) ma (1) and (4) ma (1) and (4) Max Alarm Current 210 (220) 240 250 230 ma 290 ma 110-140 ma (1) (at 24 V DC) (4) ma (1) ma (1) Starting Current Limited to 300 (390) 320 (400) 300mA 330mA 150mA ma ma Mechanical Hi-Spec All-Spec Compact Dimensions (W x H x D) 200 x 292 x 113mm 200 x 292 x 113mm 140 x 222 x 70mm Weight 1460g 1560g 1460g 1560g 850 to 895g (3) Protection Category IP 20 (Optional IP 52) IP 20 (Optional IP 52) up to IP 54 Temperature Range -20 C to + 60 C -20 C to + 60 C -20 C to + 60 C Cold Storage Option -40 C to + 60 C -40 C to + 60 C -40 C to + 60 C Humidity 10 % to 95 % relative 10 % to 95 % relative 10 % to 95 % (Permanent) humidity humidity relative humidity

Part Numbers Panels ASD-CM Honeywell Compact ASD (Including Detector) 0.5% obscuration ASD-CM2 Honeywell Compact2 ASD (Including 2 Detectors and ROOM IDENT) ALL-SPEC1 Honeywell ALL-SPEC1 ASD ALL-SPEC2 Honeywell ALL-SPEC2 ASD ASD-TP-01 Smoke Detectors for Honeywell ALL-SPEC ASD 0.1% obscuration ASD-TP-05 Smoke Detectors for Honeywell ALL-SPEC ASD 0.5% obscuration ASD-TP-001 Smoke Detectors for Honeywell ALL-SPEC ASD 0.015% obscuration HI-SPEC1 Honeywell HI-SPEC1 ASD HI-SPEC2 Honeywell HI-SPEC2 ASD ASD-TT-01 Smoke Detectors for Honeywell Hi-SPEC ASD 0.1% obscuration ASD-TT-05 Smoke Detectors for Honeywell Hi-SPEC ASD 0.5% obscuration ASD-TT-001 Smoke Detectors for Honeywell Hi-SPEC2 ASD 0.015% obscuration A silent and freezer version is also available. Please contact your local business manager for further information. For further details on these or any other Morley-IAS products please contact your local distributor, Morley-IAS Business Manager or via our contact details found below. Morley-IAS by Honeywell - Providing a control panel solution, for fire industry professionals, committed to supporting our device partners. Every care has been taken in the preparation of this datasheet but no liability can be accepted for the use of the information therein. Design features may be changed or amended without prior notice. Morley-IAS by Honeywell 2011 Charles Avenue Burgess Hill West Sussex RH15 9UF UK T: +44 (0) 1444 235 556 F: +44 (0) 1273 376 894 E: sales@morleyias.co.uk www.morley-ias.co.uk DOC REF: M300-ASD(0811)