Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during building movements Optimal access via remote operating unit at eye level Clear representation of all states via central indicator display on the operating unit High level of IP protection for usage under difficult environmental conditions Activation and reset via esserbus Transponder 0. during loop operation s from to 0 m Large assortment of accessories The LRMX Line Smoke Detector marks a new generation of infrared light-beam detectors in compliance with EN -. Based on the light absorption principle, the sender sends a pulsated infrared beam of light to the prism reflectors which are to be mounted opposite the detector. These prisms reflect the light back to the receiver. If smoke should enter the infrared light beam and dim it to a defined degree, a signal is forwarded via the esserbus Transponder to the fire alarm control panel (FACP). Both fire alarms as well as disturbance alarms are forwarded to the FACP. The prominent feature of this new generation is the automatic alignment at initial start-up and the regular adjustment of the detector head via the integrated engine in the detector. This simplifies start-up considerably and thus it can be carried out more quickly. Due to the automatic self-adjustment of the detector during even the slightest building movements, as for example due to length extensions, temperature variations, etc., the LRMX can always retain the optimal position of the initial alignment and thus is even more protected from disturbance. Operation is user-friendly via the ground-level operating and control unit which is operated remotely from the detector. The power is supplied directly to the detector, so that in the case of an operating and control unit failure, continuing operation of the LRMX is guaranteed. The operating and control indicator has an indicator display which shows all reports and states clearly and at eye-level. With the aid of the display, a manual alignment of the detector is also possible even in the case of very difficult initiation conditions, as the horizontal and vertical coordinates of the infrared light-beam are represented in detail. The connection to the esserbus-loop is carried out via the esserbus Transponder 0. in the usual manner. Resetting can also be easily carried out via this esserbus Transponder: using the tools 000 programming and service software, the relays on the transponder can be programmed as reset relays and the reset time can be set individually. In conclusion, the LRMX on the esserbus represents a significant advance in the world of line smoke detectors and guarantees an extremely high degree of disturbance-free and low-maintenance operation. esserbus/esserbus-plus V DC Application Example
0. m/!$ Linear Smoke Detector LRMX The linear smoke detector in compliance with EN - consists of detector, operating and control unit and one prism reflector. The connection to the esserbus and the resetting is carried out via the esserbus Transponder 0.. The connection to a conventional detector zone is carried out via the Reset Module. This device requires a external voltage supply of V DC for the galvanic separation of D.C. voltage potentials and the voltage converter is to be used in order to avoid ground faults. Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during building movements Optimal access via remote operating unit at eye level Clear representation of all states via central indicator display on the operating unit High level of protection from moisture for usage under difficult environmental conditions Activation and reset via esserbus Transponder 0. during loop operation This device works with the use of a prism reflector at a range of from m to 0 m. AT larger ranges, the Extender or should be used..... 0 V DC Current consumption ma (in all operational states) to 0 m Type of protection IP W: mm H: mm D: mm W: 0 mm H: mm D: mm (Operating Unit) W: 0 mm H: 0 mm D: mm (Single Prism) The LRMX is available on request with built-in heating and front plate with nano coating. Please note that the LRMX with built-in heating has not been -approved! Please also note: the reflector is no longer included with delivery and must be ordered separately! Detector, operating and control unit, prism reflector x cm Reflectors and accessories. m/" /i The individual reflectors and reflector sets can also be used with the Fireray products. However, please observe the additional planning information in the relevant functional descriptions. Reflector set for LRMX, for ranges of up to 0 m Metal reflector set for LRMX range extension of up to 0 m. Steel plate; x reflector... 0 m W: 0 mm H: 0 mm D: mm. m/# /l Reflector set for LRMX, for ranges of up to 0 m Metal reflector set for range extension of LRMX up to 0 m.... 0 m W: 0 mm H: 0 mm D: mm Reflector sets also available on request with Water-repellent Reflectors (nano coating) or additional built-in heating. Steel plate; x reflector www.esser-systems.com
m/$- Single reflector for LRMX Replacement prism single reflector for usage with the Line Smoke Detector 0.... 0 m W: 0 mm H: 0 mm Reflector sets also available on request with water-repellent surface or additional built-in heating. m/.k Nano coated reflector for LRMX Reflector sets also available on request with water-repellent surface or additional built-in heating.. m/% /r Ceiling holder for LRMX for distances from 0 to 0 cm For better mounting of the Line Smoke Detector 0 on walls, girders, ceilings and beams. The ceiling bracket is made of aluminum and can be adjusted in length anywhere from 0 to 0 cm. A high-grade ball joint mounting bracket is located on the top side for easy wall/ceiling mounting. The ceiling bracket is suitable for attaching the Mounting Plate. Ceiling bracket incl. mounting material for the aluminum holder but does not include material for mounting of the holder on ceilings, walls or beams. For easy ceiling and wall mounting in compliance with DIN VDE 0- Optimal alignment of detector and reflectors under difficult ambient conditions via ball joint mounting bracket Extendable ceiling bracket for flexible adjustment of length for distances of 00 to 00 mm Invisible cable routing inside of the ceiling Capacity kg Swivel hinge approx. Ball joint approx. 0 and holding fixture for prism reflector RAL 0 (pure white) surface m/& /u. Ceiling holder for LRMX for distances from 0 to cm Same as. but extendable for ceiling clearances from 0 to cm.
m/0q m/)< Ceiling holder for LRMX Same as. but mm long rigid design. Flush mounted housing for LRMX For the LRMX, consists of flush mounted tray and vertically adjustable cover plate frame with lockable front door. Color white, similar to RAL 0 W: mm H: mm D: mm (total) W: 0 mm H: 00 mm D: mm (flash mounting) Mounting unit for the LRMX with light cone apertures pre-stamped cable ducts with predetermined breaking points m/*? Substitute test film for LRMX Damping foil for detector testing m//n Nano detector cover Detector cover with nano coating for application to the front of the detector prevents steaming up of detector in difficult environments. m/' Mounting plate for ceiling bracket for detector/single reflector Mounting plate made of aluminium for attaching the Line Smoke Detector 0 or the Prism Reflector on ceiling bracket. www.esser-systems.com
m/( Mounting spider for Ceiling Bracket and Mounting spider for the ceiling brackets and for alternativ attachment of the reflector sets and on the ceiling bracket.
Fireray m.0o Fireray 0 RV, with one prism The detector consists of an infrared transmitter and receiver. The signal is reflected by a prism and analysed by the receiving element. Signal reaching the threshold will trigger an alarm. The actuation on the loop and the resetting function is carried out via the esserbus transponder 0.. Actuation on a conventional line is carried out via the reset module. The device requires a separate voltage supply of V DC. A compact housing Maximum range m to 0 m Robust construction Complies with EN - standard Actuation and resetting is carried out via the esserbus transponder 0. during loop operation The Fireray is installed approx. 0. to 0. m underneath the ceiling and its reflector with same ceiling distance opposite. There should be no reflecting obstacles in the transmission zone (approx. degrees)..... 0 V DC Quiescent current @ V DC approx. ma Contact load max. 0 V DC / A to 0 m Ambient temperature -0 C... C Storage temperature - C... 0 C Type of protection lp 0 Housing ABS plastic, flame resistant Color grey, similar to RAL 0 Weight approx. 0 g Detector specification EN - W: mm H: mm D: 0 mm prism esserbus Transponder Monitored Area esserbus / esserbus -PLus retro mirror V DC Operating range: up to 0 m Application example www.esser-systems.com
m.r One compact housing Maximum range 0 m to 0 m Robust construction Complies with EN - standard Actuation and resetting is carried out via the esserbus transponder 0. during loop operation m.a Fireray 0 RV, with four prisms The detector consists of the infrared transmitter and receiver. The signal is reflected by a prism and analysed by the receiving element. Signal reaching the threshold will trigger an alarm. The actuation on the loop and the resetting function is carried out via the esserbus transponder 0.. Actuation on a conventional line is carried out via the reset module. The device requires a separate voltage supply of V DC. The Fireray is installed approx. 0. to 0. m underneath the ceiling and its reflector with same ceiling distance opposite. There should be no reflecting obstacles in the transmission zone (approx. degrees). prisms Fireray 000.... 0 V DC Quiescent current @ V DC approx. ma Contact load max. 0 V DC / A 0 to 0 m Ambient temperature -0 C... C Storage temperature - C... 0 C Type of protection lp 0 Housing ABS plastic, flame resistant Color grey, similar to RAL 0 Weight approx. 0 g Detector specification EN - W: mm H: mm D: 0 mm Consisting of transmitter, receiver, and remote evaluation unit for light and dark smoke. Coverage: to max. 0 m Width of monitored area: max. m (as per ) Height of monitored area: max. m Area to be monitored: max. 0 m² Automatic compensation for pollution and ageing by -step gain control Rugged metal housing Floating contacts for alarm and trouble Test output for calibration and service Actuation and resetting is carried out via the esserbus transponder 0. during loop operation The actuation on the loop and the resetting function is carried out via the esserbus transponder 0.. Actuation on a conventional line is carried out via the reset module. The device requires a separate voltage supply of V DC..... V DC Quiescent current @ V DC approx. ma Contact load max. 0V DC / A Ambient temperature -0 C... C Storage temperature - C... 0 C Type of protection lp 0 Housing sheet steel Color grey, similar to RAL 0 Weight approx. g (Evaluating unit) approx. 0. kg (Transmitter/Receiver) Detector specification pren - W: mm H: mm D: mm Ø: 0 mm L: mm (receiver/transmitter) x mounting brackets, x screws, x grommets, x test filter esserbus Transponder Monitored Area esserbus / esserbus-plus Transmitter Receiver V DC Operating range: up to 0 m Application example