Silent Knight Software Suite Intelliknight Training

Similar documents
IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

IFP-2000 F r a en e h n y h t y PH P D

False Alarm Management

Section 8 System Operation

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Section 9 System Operation

PART IV DETAILED SPECIFICATION

False Alarm Management

Fire Alarm Control Systems Simple. Smart. Reliable.

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

4.1 Mounting the 5820 Cabinet Removing the 5820 Assembly from the Housing AC Connection Battery Connection...

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

INTELLIKNIGHT 5820XL. Installation and Operation Manual. Addressable Fire System. Part Number H, 10/03

INTELLIKNIGHT MODEL 5700

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 04/01/2011 Rev: S P/N L8:S ECN

INTELLIKNIGHT 5820XL. Installation and Operations Manual. Addressable Fire System. Document L8 05/09/2012 Rev: T P/N L8:T ECN

Fire Alarm Control Systems

SILENT KNIGHT IFP-1000

INTELLIKNIGHT Model 5808

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

INTELLIKNIGHT MODEL 5700

Section 4: Operating Instructions

Addressable Detectors & Bases

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

INTELLIKNIGHT MODEL 5808

QA16 Addressable Panel Programming Manual V3.07.3

Fire Alarm and Life Safety System Inspection Certificate

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

LifeAlarm Fire Alarm Control Panels

MODEL IFP-100. Installation and Operations Manual. Analog/Addressable Fire Control Panel. Part Number Rev L

Laptop / PC Programming Manual

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

Fire alarm system specification for multiple tenant retail buildings

Addressable Fire Alarm Control Panel

Multiple Input and Output Modules

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent Single Loop Fire Alarm Control Panel

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

2. HVAC and smoke control systems; fire, smoke, and combination fire/smoke dampers. 5. Central control and monitoring system.

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MR-2602 Two Zone Fire Alarm Control Panel

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

4010 Fire Alarm Applications Manual

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

PART 1 GENERAL Quality Assurance A. Fire Alarm Contractor Qualifications:

2000 Series. Program Entry Guide. Control Panels

Contents. Glossary

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

U ser's Guide PC6010

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

I. Synchronized Strobes 2=PROGRAMMING PROGRAMMING ENTER PASSWORD *****

INTELLIKNIGHT MODEL 5700

Fire Alarm and Life Safety System Inspection Certificate

Division 28 - Electronic Safety and Security

UNPRECEDENTED SPEED ULTIMATE POWER. EXTREME intelligence

good things in small packages

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

CITY OF PORTSMOUTH Department of Public Works MUNICIPAL COMPLEX FIRE ALARM. Bid # Addendum #1

PS-Tools. User s Guide for the 50 Pt Addr Panel

Fire System Objects. Introduction Page *3. Engineering *17. Data Base Generation *43

FARENHYT ORDER FORM Page 1 of 5

D7024 Fire Alarm Control Panel

Fire Alarm and Life Safety System Inspection Certificate

INSTALLATION MANUAL: IDC-6 INITIATING DEVICE CIRCUIT EXPANDER

GEMC-FW-SLC FIRE SIGNALING LINE CIRCUIT MODULE INSTALLATION INSTRUCTIONS

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Doc. No Part No Rev. U * T*

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MODEL IFP-2000/ RPS-2000

Fire Alarm Control Panel Model FC2005/FC901

Control/Communicator Installation Manual

IDS816 User Manual H Issued January 2009

Multi-Point Peripherals

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

EQ-ROBO Programming : Cliff Check Robot

AFP-300/AFP-400 Analog Fire Panel

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

Fire Alarm and Life Safety System Inspection Certificate

Mircom FX /01/16

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

/10 Rev A

Different types of Fire Alarm System

Fire Command Center. XR2400F User s Guide

IDP-Zone-6 Six Zone Interface Module

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Table of Contents. Appendix A Special Characters 31

Watchguard WGAP864 User Manual

Control/Communicator

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Fire Alarm and Life Safety System Inspection Certificate

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

User's Manual VISTA-40 N7003V1 6/97

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Transcription:

Silent Knight Software Suite Intelliknight Training Module 2 Summary of all the SBUS Modules and addressable points in your program System Add SBUS Module Left click, right click on Module Select Add 1

Add SBUS Module Select the type of SBUS Module to add from the list provided SBUS Module ID Left click, right click to change address of the SBUS Module Select from 1 to 31 SBUS Module Added Can see the SBUS Module you added Can Edit SBUS Module Such as the name 2

Identify what you want to look at Check options Can be sorted System Screen for adding Zones Programming zone Zone characteristics Programming Input points Detectors Pull Stations Monitor, Minimon Input Zones Adding a Zone Left click, right click to add more zones Enter starting number Indicate number of zones Can have up to 125 zones 3

Naming a Zone Left click, right click to change the name of a zone Example = First Floor Name will show when you have an alarm Detector Characteristics 2 Count 2 detectors to activate an alarm Waterflow and Pull Station are still instant Alarm Verification One detector has to go into alarm twice First time FACP resets Positive Alarm Sequence 15 second delay on alarm Giving someone with authority, time to active a PAS input for additional 180 seconds NFPA 72 6.8.1.3.1.2 Otherwise goes into alarm Detector Characteristics Single Interlock Two addressable detectors Or manual release switch Double Interlock Interlock switch Combination of two Addressable detectors Manual release switches 4

Zone Characteristics Heat Sensor left click, right click to select Can adjust heat sensor threshold 135F 150F Hochiki 135F 190F SK-Heat-HT Zone Characteristics Cadence Left click, right click to select drop down Left click select Cadence Constant March Code ANSI Temporal 3 ANSI Temporal 4 SD500-6SB Hochiki SK Intelligent Sounder Base Zone Characteristics Cadence Left click, right click to select drop down Left click select Cadence Constant March Code ANSI Temporal 3 ANSI Temporal 4 SK Intelligent Sounder Base 5

Zone Characteristics Local zone Left click, right click to select Select Yes will not report to Central Station Example = dorm rooms, hotel rooms, apartments Meant for Sounder Base Select what points you want to view Can sort by different fields Input Zones Editing SLC Points There are two categories Modules Sensors 6

Editing Input Point Names Left click, right click on Name Up to 20 characters Editing Point Types Left click, right click, on the point type Select its attributes Editing SLC Modules Only SLC Module types will be available Contact Input Relay NAC 2-wire Detector module 7

Only sensor types will be available Detector Supervisory Detector CO/Fire Detector Accessory Base Editing Sensors Detector Alarm event Detector Supervisory Detector Supervisory event Avoids potential false alarms Used in Assisted Living Dorms Hotel Rooms 8

CO\Fire Detectors Both Alarm CO Fire Alarm Supervisory CO Fire Alarm Alarm CO Supervisory Fire Both Supervisory CO and Fire Adding Accessory Base Add under Sensors Select base type Accessory Bases Sensors are assigned to a zone Accessory Bases are assigned to a group SK-DUCT detectors cannot use Single/Multi- Station and MUST be mapped to a Group Relay is an independent address 9

Accessory Options Left click, right click under Accessory Options Select Multistation (MST) Single (SST) System Mappable (SYS MAP) Single Station Hallway Apartment, dorm, assisted living Detector with sounder base in each room Single Station Hallway The hallway detectors are in a zone Same SLC, separate zone from the room detectors All of the hallway detectors can be in the same zone 10

Single Station Program Hallway When a detector activates in one room Only its sounder activates Room detectors can all be in the same zone Single Station 1 base sounds Single Station Hallway When one of the hallway smokes activates It will activate all mapped outputs Per mapping Floor above / floor below Or the whole facility Multi Station Program When one smoke detector with sounder base activates All sounder bases in that zone will activate Assisted Living Example 11

Assigning Input Points to a Zone Zone 1 is default Left click, right click Zone and modify what zone you want it to be in Must add Zone before you can assign it Assigning Input Points to a Zone You need another What's wrong with zone to change the picture? zone number 12