RDA. RDA - the server cabinet. Welded server cabinet, IP20, capacity 1800 kg

Similar documents
19 Cabinets. Eurolan. 19" Floor Standing Cabinets. Racknet Floor Standing Cabinets. Racklan Floor Standing Cabinets. Rackserv Floor Standing Cabinets

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

1. Safety instructions Mounting location in rooms of the heat detectors... 3

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

enclosuresystems.co.uk Enclosure Systems 455 Series IP55 Outdoor Wall Mounting Cabinets by Canford Cabinets and Racks for all your 19 needs

Zone Cabling & Wireless Enclosures

BUILT-IN OVEN MODEL: EBO-E7081D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

RIVERA P5000. Folding awning P5000

CVS 4 TEMPLATE CUTOUT SIZE: 180mm CVS 6 TEMPLATE CUTOUT SIZE: 250mm

Instructions for Model E782 Betman Cleaning System (Cleaner/Rinser/Rinser/Dryer)

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

Installation manual plugs and connectors QUICK-CONNECT (63 A)

CMS CMS. Template cutout size: 187mm CEILING MONITOR SYSTEMS INSTALLATION MANUAL

BUYING GUIDE VIDGA. Curtain and panel hanging system. DESIGN David Wahl

BUYING GUIDE VIDGA. Curtain and panel hanging system. DESIGN David Wahl

VIDGA. Curtain and panel hanging system. DESIGN David Wahl

Smart Series TAS-05-11, TAS-05-12

Interface Control Document Between: AOS Facilities And: Ancillary Calibration Devices

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

Refrigerators 650 & 1400 lt Smart

Industrial Automation Enclosure

Quick-disconnect cables. Adjustable mounting brackets

Practical Solutions for Combined Sewer Overflow Control. Engineering Healthy Waterways

Operating instructions for the radio heat detector GS412

architectural products

USER GUIDE. Last update on MARCH 19,

Technical Catalogue laboratory furniture system

Curved Metal Panel Heater

STORAGE ROLLER CABINETS & TOOL CHESTS...8 MODULES...12 FURNITURE SHOP...18 MAGNETIC ACCESSORIES...21 WORKSHOP TROLLEYS...22 METAL CHESTS...

WOOD CHIP HEATING HPK-RA

Big Board Rework. Joerg Nolte Ersa GmbH Wertheim, Germany

TOOL BOXES PRO SERIES 26" X 12" 6 DRAWER MECHANIC'S CHEST 26" X 12" 10 DRAWER MECHANIC'S CHEST

MASK2. Instruction manual

Air Shower TECHNICAL DATA

Model KBF 240 Constant climate chambers with large temperature / humidity range

VIDEOLIFT MOTORIZED CEILING BRACKET. Videolift

P R O D U C T D ATA S H E E T

Operating Instructions

2018 Special-Lite ALUMINUM HARDWARE & LITES

MASK4(T) & MASK6(T) Instruction manual

AXTER HYDROPACK AND SEDUM MAT INSTALLATION AND MAINTENANCE GUIDE

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Reflex fire detection and extinguishing system filled with ABC dry powder. Installation, operation and maintenance instructions

DATASHEET REV.1.0 Data center System

AV equipment racks for residential installations

Industrial Cable Support HALOGEN-FREE - FIRE RETARDANT - OPTICAL FIBER DUCTING

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

Installation Instructions for Med Touch Master Alarms - Wireless

CMS CMS C E I L I N G M O N I T O R SYSTE M S I N STA L L ATIO N M A N U A L. CMS801 TEMPLATE HOLE CUTOUT SIZE: 295mm (11.61 )

Display coolers Special 2016 / 2017

USER S MANUAL ATH WH220

Velando Compact Space

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Standards and Procedures. Installation of Cameras and Camera Systems At University of North Carolina at Wilmington UNCW

Installation Guide: PowerAire Quad

Proven Heritage RTS STANDARD EQUIPMENT. (413) FAX: (413) You can rely on Smith Cast Iron

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

DEMAND CONTROL OPTION PCB

HVAC Module Assembly Replacement. Tools Required. J A Halogen Leak Detector. Removal Procedure

CARTS AND MOPPING SYSTEMS

Aegean Range. A new range of fan coils for heating and cooling commercial applications

FDCL221 Line separator

INSTRUCTIONS FOR OPERATION

Universal Connectivity Platform A Modular Approach to Infrastructure Design

BUILT-IN OVEN MODEL: EBO-D7080D(SS) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

2.2 Drawing and Parts List

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

Unrivaled Underbar Features

SECTION COMMUNICATIONS FIBER CABINETS, ADAPTERS AND CONNECTORS

RMR Fixed Wall-Mount Enclosure

Bracketed Systems. Scalloped Newbury. Newbury. Features & Benefits. Brookhaven. Brookhaven with Lattice. Size: 6' high x 8' wide

Technical Catalogue laboratory furniture system

CEILING SPEAKER SYSTEM

STRIP CUT PAPER SHREDDER

CZ51202 Larder fridge

Contents. NT & TAS - For orders in these states please add 5% transport surcharge to your purchase price 1-K. Price Guide - February 2017

Instructions for Use and Warranty Details. RH17-900mm Island Canopy Rangehood

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

Art and Picture Hanging Rail Systems SYSTEMS. Display with Elegance

Environmental Safety Risk Assessment Inpatient Behavioral Health Settings (Compiled from tools in the public domain)

INSTRUCTIONS. Installation, operation and care of CLD COLD SERIE MULTIDECK COLD FOOD DISPLAY CASES IMPORTANT READ BEFORE USING DISPLAY CASE

PFIC1NFZ GE Profile Counter-Depth 20.9 Cu. Ft. Bottom-Freezer Drawer Refrigerator

Two (2) Side Rail Cable Tray

MOUNTING GUIDE. MOUNTING INSTRUCTIONS FOR MODULAR UNDERFLOOR HEATING MESH FOR INDOOR code PVMR

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

Workbenches Tool carts Metal lockers.

IMS500 (Invetex Monitoring System Model 500)

6U Wall-Mount Server Rack Cabinet - Up to 14.8 in. Deep

ВОДЯНЫЕ И МАСЛЯНЫЕ БАНИ

NABTEB Past Questions and Answers - Uploaded online

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Manual & Technical Documentation V1.1

From the World Leader in VRLA Battery Technology

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

8U Vertical Server Cabinet - 30 in. depth

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

CASSETTE UNIT. Comfort Circle

Transcription:

R 0 0 0 0 0 1 1 0 0 1 0 0 0 1 1 1 1 0 1 0 1 0 1 0 1 1 1 1 R - the server cabinet Welded server cabinet, IP20, capacity 1800 kg 47

R Loading capacity 1800 kg The R data cabinet has a reinforced construction and it is made of thicker material. lso 19 vertical rails are designed for a higher loading capacity. version with depth over 800 mm has a central pair of vertical rails as a standard solution. Hook-on hinges Our standard door hinges can be replaced by its new put-in alternative. oor can be taken off, which allow an easy installation and configuration of all installed equipment. These hinges are fully compatible with previous versions. Please refer to section ccessories. Triton handles We manufacture our own handles for the free-standing cabinets. By changing the plastic module (not included), a traditional or semicylindrical lock insert can be used. Patent: PUV 2013-27443 R 800 x 1000 mm Wider body rails Wider rails in the body of a cabinet are intended for an additional installation of 19 power management panels, which afterwards do not occupy space within the cabinet. Thanks to this smart solution of gripping, it does not block sliding servers even for the 600 mm wide cabinet type. In addition to this solution the 5 version (at the end of the cabinet code) is characterized by break-out blanking panels for possible cable input and management in between neighbouring cabinets. 48

R-42-L81-CX-1-G R-42-L81-CX-5-G B B R C C R data cabinet The R data cabinet is intended for servers and active equipment for computer networks. It is usually supplied with a perforated door to provide maximum cooling. It is possible to improve cooling by installing fan units to the ceiling or to the base section of the R cabinet. Cable entries above 19 vertical rails are covered with break-out blanking panels and also provide with an easy connection of installed technologies into a larger unit. slightly different version is developed for ata centers. R free standing server cabinets model 1 and 5 Type B C R-37-L68-CX-x-G 1750 1648 487 600 800 104,3 96,0 R-42-L68-CX-x-G 19 1868 487 600 800 113,3 104,8 R-45-L68-CX-x-G 2105 2003 487 600 800 118,8 110,1 R-47-L68-CX-x-G 2194 2092 487 600 800 121,6 113,0 R-37-L61-CX-x-G 1750 1648 487 600 1000 121,8 110,9 R-42-L61-CX-x-G 19 1868 487 600 1000 131,7 120,7 R-45-L61-CX-x-G 2105 2003 487 600 1000 137,8 126,8 R-47-L61-CX-x-G 2194 2092 487 600 1000 141,1 130,1 R-37-L60-CX-x-G 1750 1648 487 600 1100 129,8 116,9 R-42-L60-CX-x-G 19 1868 487 600 1100 140,1 127,1 R-45-L60-CX-x-G 2105 2003 487 600 1100 146,4 133,4 R-47-L60-CX-x-G 2194 2092 487 600 1100 149,9 136,8 R-37-L62-CX-x-G 1750 1648 487 600 1200 133,3 121,1 R-42-L62-CX-x-G 19 1868 487 600 1200 145,9 133,6 R-45-L62-CX-x-G 2105 2003 487 600 1200 152,4 140,1 R-47-L62-CX-x-G 2194 2092 487 600 1200 154,9 142,7 R-37-L88-CX-x-G 1750 1648 687 800 800 153,8 139,4 R-42-L88-CX-x-G 19 1868 687 800 800 129,9 120,1 R-45-L88-CX-x-G 2105 2003 687 800 800 135,5 125,6 R-47-L88-CX-x-G 2194 2092 687 800 800 135,5 125,6 R-37-L81-CX-x-G 1750 1648 687 800 1000 138,7 128,7 R-42-L81-CX-x-G 19 1868 687 800 1000 141,1 137,6 R-45-L81-CX-x-G 2105 2003 687 800 1000 157,5 143,8 R-47-L81-CX-x-G 2194 2092 687 800 1000 161,0 147,4 R-37-L80-CX-x-G 1750 1648 687 800 1100 147,6 134,6 R-42-L80-CX-x-G 19 1868 687 800 1100 158,2 145,1 R-45-L80-CX-x-G 2105 2003 687 800 1100 164,6 151,6 R-47-L80-CX-x-G 2194 2092 687 800 1100 169,7 155,1 R-37-L82-CX-x-G 1750 1648 687 800 1200 153,8 139,4 R-42-L82-CX-x-G 19 1868 687 800 1200 166,8 152,2 R-45-L82-CX-x-G 2105 2003 687 800 1200 173,5 158,8 R-47-L82-CX-x-G 2194 2092 687 800 1200 177,3 162,5 (mm) Weight gross (kg) Weight net (kg) Maximum recommended load (kg) 1800 With exact configuration will help you program on our website http://www.triton.cz/en/konfigurator. 49

Variant 1 R Variant 5 50

Variant 3 for data centers R Variant 7 for data centers 51

Server cabinet R R escription, purpose of use 19 free-standing cabinet with IP20 protection Cabinet includes 4 sliding vertical rails for device mounting (6 rails for cabinets deeper than 800 mm). Cabinet construction: Welded steel frame with removable side panels fixed by locks Single or double doors in all metal versions, perforated (80 % and 86 % air permeability) or glazed with safety tempered glass 4 mm. They can be on the front or back of the cabinet. Preparation for installation of power distribution units to the frame Preparation for joining the cabinets together 5 version has a breakout cable entries in the frame for the cabling between cabinets The maximum recommended load of cabinet is 1800 kg, maximum load of the door is 20 kg. Min. thickness of the surface finish is 65 µm. The racks are designed for installation of data and telecommunication equipment and distribution systems. The frame of the cabinet and all the removable parts (side and rear covers, doors ) are bonded with patch cables that have to be properly fixed and inserted into connectors throughout the period of use of the cabinet. There is one M8 screw placed on the bottom part of the cabinet to connect the bonding. Can be mounted on castors and levelling feet. Cable openings covered with breakout-type blanking panels are placed in the top and the bottom part of the cabinet. Operating conditions Operating environment: Office The cabinet is not intended for outdoor installations and for installations in environment that can influence negatively the functionality of the cabinet and the mounted devices (e.g. environment with danger of explosion) Must be protected against: Mechanical damage Improper handling different usage than the cabinet is intended for Improper handling is especially: Overloading (exceeding the maximum recommended load) Installing devices which may negatively influence the operation and function of the cabinet or the installed equipment. Change of the construction or design of the cabinet Installation of the cabinet To ensure the maximum recommended load, it is necessary to distribute the load equally. Place the cabinet on a flat floor and adjust any differences using the levelling feet. To avoid dust penetration in the case where cables lead through some of the cable openings, it may be sealed with a blanking panel with a brush or secured by a plastic frame (both are included in the delivery). nvironmental protection ll parts are made of recyclable materials and after decommissioning the cabinet, it must be disposed of according to relevant regulations Certificate and conformity This product is certified with ITI TÜV, number of certificate 06.033.157/r1, date 20/08/2015 and is fully in accordance with ČSN N 62208 ed.2:2012(n 62208:2011). 52