MXL/MXLV Enclosuress & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4

Similar documents
MXL/MXLV 19 Rack Mount Equipment

Fire Safety. Installation Instructions. Model RCC-2/R and RSE-1 Remote Control Centers OPERATION INTRODUCTION INSTALLATION

Advanced Protection System

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Fire Safety. Installation Instructions Model PSR-1 Remote Power Supply INTRODUCTION. Figure 1 PSR-1 Remote Power Supply

AND ARCHITECT SPECIFICATIONS

AND ARCHITECT SPECIFICATIONS

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Air Duct Housings. Description

Fire Safety. Installation Instructions Model D2300CPS Fiber Optic Interface INTRODUCTION MOUNTING ELECTRICAL CONNECTIONS. Figure 1 D2300CPS Module

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

System Overview (continued) System Components. The FireFinder XLS system has been seismic qualified in accordance with:

Marine Fire Detection System Manual MXL Control Panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Operating Instructions MXL Multi-Line Keyboard/Display Panel

E3 Series Broadband System

E3 Series Broadband System

Cerberus PRO Modular system

MXL-IQ CONTROL PANEL. Operation, Installation, and Maintenance Manual. Siemens Industry, Inc. Building Technologies Division Florham Park, NJ

Installation Manual For The Mxl Panel READ ONLINE


June 10, 2002 DF C S2424

Siemens Fire Alarm Panel Xls Operation Manual READ ONLINE

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

July 14, 1999 DF C-100.

Network Display Unit Installation Instructions

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Submittal Transmittal, Consultant

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

Inside a typical. Intelligent Voice Communication System. Mounting Diagram. 2 Cerberus PRO. 252 / 504-point Cerberus PRO fire / voice system

FIREFINDER-XLS CONTROL PANEL

ANNUNCIATOR FIXED MODULE

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Vibratone Horns. Models 350 and 450

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

INTELLIGENT FIRE ALARM CONTROL PANEL

SC-6 Six Supervised Control Module

Innovative protection that combines power and flexibility

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Fire Safety. Installation Instructions Model NIM-1W Network Interface Module MXL NETWORK INTERFACE APPLICATIONS OPERATION NIM-1W

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

FIREFINDER-XLS CONTROL PANEL

P126FTT Fiber Transfer Terminal

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

FireSeeker Model FS-250C Addressable Fire Alarm Control Panel

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Conventional Fire Detection

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Installation Instructions for Med Touch Master Alarms - Wireless

Bosch EVAX System - High-rise Applications

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

2 PREPARE THE OPENING

License Agreement. Trademarks and Copyright

SECTION FIRE ALARM SYSTEMS

1022 R/T Remote Monitor

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

Panel Remote Annunciators Installation Instructions

SIA/IAPSC CAD Security Symbols

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

Cerberus PRO A comprehensive fire-protection system

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Fire Control Panels. Network Annunciator Panels Network Display Unit (NDU) UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

/ How To Order

The following information shall become and form part of the contract documents.

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Desigo TM Fire Safety System A comprehensive fire-protection system

CARD ACCESS CONTROL SYSTEM

UL Systems. UL intelligent addressable systems Product Name

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

MOUNTING DETAILS. Mounting Matrix / Details ENGINEER AND ARCHITECT SPECIFICATIONS CATALOG SHEET. 2-1/8 Deep

7800 SERIES EC7885A/RM7885A Relay Module

NOTE TO SPECIFYING ARCHITECT REGARDING SECTION PERFORMANCE LIGHTING SYSTEM (24 DIMMERS)

[DOC] SIEMENS MXL FIRE ALARM PANEL OPERATION MANUAL

ELP21LU3-LF-HLOL THREE CHANNEL

TECHNICAL MANUAL UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Colibri. Automatic Tank Gauge CL6 Series Installation Guide

DESIGN GUIDELINES AND TECHNICAL STANDARDS

Extreme High-Intensity Sensors Thru-Beam and Fiberoptic Penetrates Many Packaging Materials for Content Verification

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

2 Specialty Application Photoelectric Sensors

CATALOG NUMBER. Features. Description

NETWORK FIRE ALARM CONTROL PANEL. Features

I NSTALLATION M ANUAL

1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Model FH-2071-UM Enclosure

RETAIL Price List - Valid From March 2017

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

16 Zone Voice Evacuation VA & PA Sound System

Transcription:

MXL/MXLV Enclosuress & Equipment Models: MME-3, MBR-MP, MLE-6, MBR-3MP, MDL-1, MDB-1, MDG-1, MHD-1, MHD-2, MHD-3, MHD-4 ENGINEER AND ARCHITECT SPECIFICATIONS Enclosure & Door Package (MME-3) Standard Size MXL Enclosure Removeable Module Mounting Plate (MBR-MP) Hinged Locking Door with Optional Inserts for Clear Lens, Grill, Blank Plate Mounting for (1) MMB or PSR-1 and Up to 3 Cardcages (MOM or OMM) Listed Enclosure & Door Package (MLE-6) Large Size MXL Enclosure Removeable Module Mounting Plates (MBR-MP & MBR-3MP) Hinged Dual Lock Door with Optional Inserts for Clear Lens, Grill, Blank Plate Mounting for (1) MMB or PSR-1 and Either Up to 6 Cardcages (MOM or OMM) or Up to 3 Cardcages and 2 EL-410 Amplifiers (MSR-1 Rail Kits) Listed CATALOG NUMBER 5056

Description The MME-3 and MLE-6 enclosures provide a complete set of hardware for mounting all MXL and MXLV modules for various system size requirements from small to large. Included in the enclosure series are backbox and door sets, removeable mounting plates and clear lenses, louvered ventiliation grill plates, and blank plates for use with the enclosure doors. Dead front covers for use alone, with switch and/or annunciator modules and with a strip printer are also available. This equipment is approved for operation over the temperature range of 0 C to 49 C. MME-3 MXL/V Standard Size Enclosure The MME-3 enclosure set consists of a sheetmetal backbox and door with keylock. The MME-3 can be used for either the MXL System, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (using the MSR-1 Rail Kit). To mount MXL/MXLV modules in the MME-3, the MBR-MP removeable module mounting plate is required. Using the MBR-MP mounting plate (1) MMB or (1) PSR-1 and up to 3 expansion cardcages (MOM or OMM) can be mounted in the MME-3 enclosure. When used to mount MXL amplifiers (EL-410), the MBR-MP is not required, instead up to (3) EL-410 amplifiers may be installed in the MME-3 by using (3) MSR- 1 rail kits. When amplifiers are mounted in any enclosure always install MDG-1 grills in the door for proper ventilation. MME-3 is designed for surface of semi-flush mounting and includes various knockouts for wire and conduit entry. The door in the MME-3 set has two cutouts for either clear lenses, blank plates or grills depending on the application, and contains a key lock. MBR-MP MME-3 and MLE-6 MXL Module Mounting Plate The MBR-MP MXL/V Module Mounting Plate is required for use in both MME-3 and MLE-6 enclosures to mount all MXL and MXLV equipment. MBR-MP is not necessary if the MME-3 and MLE-6 enclosures are to be used only for mounting of amplifiers (EL-410). The MBR-MP is a removeable MXL/V module mouting plate that allows the enclosure MME-3 or MLE-6 to be shipped to the job site for installation of wiring and conduit, while the system hardware (electronics) is mounted to the studs on the MBR-MP, pre-wired, programmed and tested prior to delivery and installation at the job site. This allows for quicker, more efficient system start ups with less chance of the sensitive electronics being damaged while field wiring and conduit are connected to the system enclosure. MBR-MP mounting plate bolts to either the MME-3 or MLE- 6 enclosures for easy installation on the job site. The MBR- MP also has handles to allow easy transport and mounting. The MBR-MP contains mounting studs for (1) MMB or PSR- MBR-MP w/ MXL Equipment Connected 1, (1) PIM-1, (1) TBM-1, and up to (3) MOM or OMM cardcages or 2 cardcages and (1) TSP-40 Printer (same mounting studs as the MBR-2 enclosures). The MBR-MP is ordered and shipped seperately from the MME-3 and MLE-6 enclosures. MLE-6 MXL/V Large Size Enclosure The MLE-6 enclosure set consists of a sheetmetal backbox and door with two key locks. The MLE-6 can be used for either the MXL system, MXLV Voice Command Console, MXLR Transponder, MXLRV Voice Transponder or Amplifier Equipment (using the MSR-1 rail kit). To mount MXL/V modules in the MLE-6, the MBR-MP removeable module mounting plate is required with the MBR-3MP optionally available for use. Using the MBR-MP mounting plate (1) MMB or PSR-1 and up to (3) expansion cardcages (MOM or OMM) can be mounted in the MLE-6. If additional MBR-MP MLE-6 w/ 6 Cardcages

cardcages are required, the MBR-3MP optional cardcage mounting plate can also be installed in the MLE-6 below the MBR-MP. The MBR-3MP allows mounting of an additional (3) MOM or OMM module expansion cardcages. Various combinations of hardware can be installed in the MLE-6. If only amplifiers are to be installed in the MLE-6, no MBR-MP or MBR-3MP plates are required. Instead up to (5) EL-410 amplifiers can be installed by using (5) MSR-1 rail kits. The MLE-6 can also be used to mount up to (3) MXL cardcages and (2) amplifiers. This configuration would be typical of a remote voice transponder cabinet. In this configuration (1) MBR-MP would be used in the upper half of the MLE-6 to mount the MXL modules, while the lower half would use (2) MSR-1 rail kits to mount up to (2) EL-410 amplifiers. MBR-3MP MLE-6 Optional Cardcage Mounting Plate The MBR-3MP is an optional MXL/MXLV cardcage mounting plate for use exclusively in the MLE-6 enclosure. When installed in the MLE-6 backbox, the MBR-3MP adds the option of mounting up to an additional (3) MOM or OMM expansion cardcages. MBR-3MP MDL-1 Clear Lens The MDL-1 is a clear Plexiglas lens which fits in either one of the two openings in the MME-3 enclosure door or in one of the three openings in the MLE-6 enclosure door. One lens is included in the MDL-1 package. MLE-6 w/ MBR-MP & (2) Amplifiers The MLE-6 is designed for surface or semi-flush mounting and includes various knockouts for wire and conduit entry. The door supplied with the MLE-6 set has (3) cutouts for either clear lenses, blank plates or grills, depending on the application. The door also contains (2) key locks keyed the same. MDL-1 MDB-1 Sheet Metal Blank PLate The MDB-1 is a sheet metal blank plate which fits in either one of the two openings in the MME-3 enclosure door or in one of the three openings in the MLE-6 enclosure door. One blank plate is in the MDB-1 package. MLE-6 w/ Door Closed Various combinations of dead front mounting plates are possible with the MLE-6 enclosure. A typical MXLV installation would have (1) MKB-2 at the top, and (2) MHD-3 dead front plates in the middle (for (14) VSM/VLM/VFM modules per plate) and (1) or (2) MHD-2 lower dead front plates. MDB-1

MDG-1 Louvered Ventilation Plate The MDG-1 is a louvered plate that mounts in either one of the two openings in the MME-3 enclosure door or in one of the three openings in the MLE-6 enclosure door. The MDG- 1 is required on MXLV systems to provide ventilation for the enclosures when using either the EL-410 or the ZAC-30 audio amplifiers in that enclosure. One MDG-1 plate is included in the MDG-1 package. MHD-2 MDG-1 MHD-1 Upper or Middle Dead Front Panel The MHD-1 is a hinged sheet metal panel which attaches to either the MME-3 or the MLE-6 enclosure backbox. It fits in either the upper or the middle section of the MME-3 backbox or the upper or either of the two middle sections of the MLE-6 backbox. It has an opening with a cover plate for the TSP-40 printer when used and attaches to the backboxes with screw fasteners. When in place it covers and protects modules and wiring, providing dead front construction in that area. MHD-3 Middle Dead Front Plate for Mounting Switch/LED/Fan Control Modules The MHD-3 is a hinged sheet metal panel that attaches to the MME-3 or MLE-6 backboxes. It fits in either the middle of the upper sections of these enclosures. It has openings for two rows of VSM-1 Switch Modules, VLM-1 LED Annunciator Modules, VFM-1 Fan Control Modules or VSB-1 Blank PLates. Each row can mount up to (7) modules for a total of (14) modules per MHD-3. The MHD-3 attaches to the backboxes with screw fasteners. It is hinged for easy access to the rear of the modules and inside of the enclosure. MHD-3 MHD-1 MHD-2 Lower Dead Front Panel The MHD-2 is a hinged sheet metal panel which attaches to either the MME-3 or the MLE-6 backboxes. It mounts in the lower section on the MME-3 and on the lower two sections of the MLE-6 backbox. It has no openings and attaches to the enclosures with screw fasteners. When in place, it covers and protects modules and wiring, providing dead front construction in that area. MHD-4 Middle Dead Front Plate for the Switch/LED/Fan Control Modules with Printer Cutout The MHD-4 is a hinged sheet metal panel that attaches to the MME-3 or the MLE-6 backboxes. It fits in the middle section of both enclosures. It has two rows for mounting of VSM-1 Switch Modules, VLM-1 LED Annunciator Modules, VFM-1 Fan Control Modules or VSB-1 Blank Modules. Each row has space to mount (4) modules, for a total of (8) modules per MHD-4. The MHD-4 also has a cutout to display the TSP-40 Internal Thermal Strip Printer. The MHD- 4 mounts to the backboxes with screw fasteners. It is hinged for easy access to the rear of the modules and inside of the enclosure. When in place, it covers and protects modules and wiring, providing dead front construction in that area.

MHD-4 VSB-1 Switch Blank Plate The VSB-1 is a blank plate which covers one opening in either the MHD-3 or MHD-4 dead front panels. It attaches to the MHD with screw fasteners. VSB-1 MSR-1 Rail Kit The MSR-1 is a System 3 type rail kit which fits into either the MME-3 or the MLE-6 enclosures. The MSR-1 comes with a U-bracket and a Z-bracket. It allows modules such as the EL-410 amplifier, PS-35 Power Supply, BC-35 Battery Charger, MOI-7 I/O Interface, MID-16, MOD-16, PS-5A, SYS3-MPFO for mounting either the D2300CP or the A2300CP fiber optic interface modules or the CCU interface, or any other System 3 type module required to be mounted in the MME-3 or the MLE-6 enclosures. When used in the MME-3 enclosure (3) MSR-1 Rail Kits can be installed to mount up to three rows for up to (3) EL-410 amplifiers. When used in the MLE-6, up to (5) MSR-1 Rail Kit rows can be installed to allow mounting up to (5) EL-410 amplifiers. When the MLE-6 enclosure is used with the MBR-MP mounting plate to install MXL or MXLV equipment, up to (2) MSR-1 Rail Kit rows can also be installed in the MLE-6 for mounting of either (2) EL-410 amplifiers or some complement of System 3 type mount modules. Ordering Information MSR-1 Model Description Part Number MME-3 MBR-MP MXL/V Medium/Standard Enclosure (Backbox and door pkg.) Requires MBR-MP to mount MXL/V modules. Removeable module mounting plate needed for MME-3 and MLE-6 Enclosure. Allows mounting of up to 3 cardcages (MOM/OMM) 500-694209 500-694210 MME-3R Red version of MME-3 Enclosure. 500-694892 MME-KIT MME-KIT/R MLE-6 MBR-3MP Kit consisting of (1) MME-3 and (1) MBR-MP Enclosure and Module Mounting Plate Kit consisting of (1) MME-3R and (1) MBR-MP. Red Enclosure and Module Mounting Plate MXL/V Large Enclosure (Backbox and door pkg.) Requires MBR-MP to mount MXL/V modules. Cardcage Expander Mounting Plate for use with MLE-6 allows mounting of up to (3) additional cardcages (MOM/OMM) in the MLE-6 for a maximum total of (6) MOM or OMM cardcages in the MLE-6 599-694894 599-694895 500-694530 500-694532 MLE-6R Red version of MLE-6 Enclosure. 599-694893 MLE-KIT MLE-KIT/R Kit consisting of (1) MLE-6, (1) MBR-MP and (1) MBR-3MP Large enclosure and both module mounting plates Kit consisting of (1) MLE-6R, (1) MBR-MP and (1) MBR-3MP. Red large enclosure and both module mounting plates 599-694530 599-694893 MDL-1 Clear Lens (1) 500-692070 MDB-1 Sheet Metal Blank (1) 500-692070 MDG-1 Louver Door Plate (1) 500-692213 MHD-1 Dead Front Panel (1) 305-092071 MHD-2 Dead Front Panel (1) 305-092072 MHD-3 Dead Front Panel (1) 305-092073 MHD-4 Dead Front Panel (1) 305-092074 VSB-1 Switch Blank (1) 500-692075 MSR-1 Rail Kit 545-592078

Mounting Diagram MME-3 Backbox MLE-6 Backbox NOTICE: The use of other than Cerberus Pyrotronics detectors and bases with Cerberus Pyrotronics control equipment will be considered a misapplication of Cerberus Pyrotronics equipment and as such void all warranties either expressed or implied with regards to loss, damage, liabilities and/or service problems. Cerberus Pyrotronics 8 Ridgedale Avenue Cedar Knolls, NJ 07927 Tel: (201) 267-1300 FAX: (201) 397-7008 4/96 10M CPY-IG Printed in U.S.A. Cerberus Pyrotronics 50 East Pearce Street Richmond Hill, Ontario L4B, 1B7 CN Tel: (905) 764-8384 FAX: (905) 731-9182 April 1996 New Issue