The complete residential solution

Similar documents
DON T WAIT UNTIL IT S TOO LATE! Discover the seven steps to a safe and secure home.

Mains Power Filter 970MF10 970MF20. Installation Instructions

Smoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms

Clipsal Iconic Collection

Get connected with Xantrex Grid-Tie Inverters

Arc Fault Detection Devices. 18th Edition - We re ready

Clipsal Mining Solutions. Increasing workplace safety. Adding value to mining operations.

SMART HOME LIGHTING CONTROL C LIPSAL

Push Button Electronic Timer. 31VETR Series. Installation Instructions

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

Consumer Switchboards 4CS & 4FCS. Installation Instructions

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Guide to: 17 th Edition Consumer Units

5SM6 AFD unit preventive, proven, standard-compliant

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Clipsal Residential Safety and Security Solutions

Welcome to Hager Presentation

Push Button Electronic Timer. 31VETR3 Series. Installation Instructions

C-Bus Four Channel Analogue Output Unit Installation Instructions

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

A BITESIZED GUIDE TO AFDDs AND FIRE PROTECTION

Airflow. Add a little Sunshine to your bathroom

Motion sensors for every application

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

Product Guide Low Voltage Switchboard & Switchgear

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Flexibility from floor to ceiling

G Series Inverter Split Systems

NOVALED. The Revolutionary downlight is re-powered

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

C-Bus Application Note. Function Rooms and Ballrooms. Overview

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

C-Bus Four Channel General Input Unit Installation Instructions

BOILING CHILLED SPARKLING FILTERED INSTANTLY ON TAP

TANKER FILLING STATIONS

Evacuate everyone Sonos Pulse & Nexus Pulse

MULTIPLE COMPRESSOR SYSTEMS COMPRESSOR PACKAGES ORIGINAL MANUFACTURED EQUIPMENT. Multiple Compressor Systems BA AUS

Siemens Hardware. Better to play it safe! SENTRON protection devices for modern electrical installations

MLHG6-AU. Iso-Gard Line Isolation Monitor (LIM) Setup Guide ! WARNING. Components

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

Quality. Trust. Value. Safety.

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Engineering Guideline. pac- Carriers Type Universal

Convection Panel Heater

SCHEDULE OF RATES SHEET PRELIMINARIES

Electrical Safety Tips. Help us keep you safe.

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

ELECTRICAL APPLIANCE SERVICEPERSON EXAMINATION 7 May 2016 QUESTION AND ANSWER BOOKLET

Universal Clamp Meter

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

GAS COOKTOPS INSTALLATION INSTRUCTIONS. Model numbers ICBCG15 ICBCG304 ICBCG365

Airflow. The coolest way to save energy

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

Level 3 NVQ Diploma in Domestic Plumbing and Heating ( /025)

Clipsal is a registered trademark of Clipsal Australia Pty Ltd. Saturn is a trademark of Clipsal Australia Pty Ltd.

medilec The Tools of a Specialist medical electrical equipment clipsal.com/cis

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

AS/NZS 3190:2011 AS/NZS

Installation, Operation & Maintenance

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

PLW PLW TOP LOAD. PV Hot Water Controller. PV Solar Hot Water Controller PLASMATRONICS. Manual. Read this before installing. Rev. U3.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

LoadCentre KQ Distribution boards

MTRA-FSP Level Control Relay. Installation & Operation Manual

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

StarServe Data Home Distribution Units. Fibre to the home. solutions

Consumer Units for Domestic Household (and other) Premises. Amendment No. 3 BS 7671

And now: sit back and enjoy the presentation! elearning, ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Room Master

Infinity. Continuous Flow Hot Water

THE ULTIMATE HEATING + COOLING GUIDE PCRAU0318

STOP HOUSE FIRES BEFORE THEY GET STARTED! 1. Product Profile Market Features and Benefits Performances 5-9. Page 1

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

QUICKSMART Universal Exit Light EXITSM. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

NERGYTOWER. energytower Leader in style, quality and safety. ground distribution turrets

C-Bus Application Note. Standard Meeting Room. Overview

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

DALI EMERGENCY LIGHTING ...MADE EASY DALI EMERGENCY LIGHTING TAP SCREEN TO CONTINUE N-LIGHT - REF: 7294V3 04/12 POWERED BY: DALI EMERGENCY LIGHTING

Electricity Merit Badge Prerequisites

OPERATING INSTRUCTIONS

Line Isolation & Overload Monitor. E05 Series. Installation Instructions MU TE TE S T E. S.P. ALARM MUT E D OVE R LOAD WAR NING PHC WARNING

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Residual Current Devices

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Operation and use. Functions and characteristics

DUCTED SYSTEMS AND ZONING SOLUTION

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Contact Details. Please note that some of the contact details on this PDF document may not be current.

IMPROVE ON PERFECTION

TECHNICAL DATA AND REFERENCE STANDARDS. Essential electrical data* Resistance at test voltage (V) Insulation resistance (MΩ)

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Loadstar AC/DC Systems

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

All Valve Industries. General Product Overview. Distributed by All Valve Industries. Ph: Fax:

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Have you checked your smoke alarm?

Transcription:

The complete residential solution Circuit Protection Resi MAX Clipsal.com/ResidentialProtection

Contents What s new in final distribution residential...3 Resi MAX gives you the entire solution...4 Essential safety for every home...6 Pre assembled Load Centre...7 Arc Fault Detection Device...8 Wiser Link energy metering...10 230 series meter boxes...11 Technical information...12 2 Clipsal.com

What s new in final distribution residential Resi MAX: The Complete Solution Clipsal by Schneider Electric now offers the complete solution in consumer switchboards with 8, 12, 18, 24 & 36 module flush and surface mounted enclosures. Compact and light in design, the range of Resi MAX enclosures provide cost effective solution without compromising on quality. Need more DIN Space in your switchboard? New 24 and 36 module enclosures provide ample space for products like Wiser link and C-Bus to be installed in one switchboard. Pre assembled Load Centre Your fully customised, connected Resi MAX TM system, pre assembled and delivered. Perfect for multi dwelli ng projects. Never be caught on site missing a component again with this easy to order, residential circuit protection offer. A new level of safety The Arc Fault Detection Device (AFDD) is an easy to install, cost effective solution to help keep your customers safe from electrical fires caused by arc faults. AFDDs safeguard against electrical fires by detecting even the smallest electrical arcs caused by cable or electrical contact damage and disconnect power before the resulting heat starts a fire. Solar monitoring and alarming for Wiser Link Wiser Link now measures solar PV production in real time. Solar production can be displayed in kwh and converted to dollar amount saved. This information is also available in detailed graphs, allowing daily, weekly, monthly, and yearly comparisons. Download the latest Wiser Link app and you will be able to set alarms on energy consumption by sub-circuit (at the CT level). Receive push notifications or emails when a particular circuit, such as your HVAC or pool pump, is about to reach the energy target for the month, increasing usage awareness and helping your customers reduce their bills. Life Is On Clipsal 3

Resi MAX gives you the entire solution With products to protect Australian homes from top to bottom, the Resi MAX range has expanded. Now including a comprehensive range of consumer switchboards from 8 pole to 36 pole and surge arrestors along with residential circuit protection, Resi MAX is the only name you need to remember for a whole suite of products. Resi MAX range From miniature circuit breakers and isolator switches, to RCDs and RCBOs, Clipsal s Resi MAX range offers unrivalled flexibility. A complete product range of electrical solutions for Australian homes 8 module to 36 module electrical distribution consumer switchboards (flush-mounted or surface-mounted) Circuit protection Switches and connectors All Resi MAX products fit easily into Clipsal s quality range of consumer switchboards and meter boxes. Comb busbars and accessories are also available to simplify the installation. Surge protection device SLIM RCBO MCB Isolator switch Consumer switchboard Busbar range SLIM comb busbar 4 Clipsal.com

Consumer switchboards Optimised to complement the Resi MAX range, these attractive, economical consumer switchboards are designed with the electrical contractor in mind. Available in flush and surface mounted versions, our switchboards are easy to install and offer generous wiring room, making connecting and running cables a breeze. Surface mount Flush mount SLIM RCBO The Resi MAX range also offers a SLIM RCBO. Rated at 4.5 ka, it achieves a 6 ka rating when combined with the HRC service fuse, which every residence on the grid is provided with. This feature provides peace of mind when using the SLIM RCBO on any residential application. Surge protection device When lightning strikes, there are no second chances. The Resi MAX range of surge protection devices won t let you down. Life Is On Clipsal 5

Essential safety for every home Flexible installation The Resi MAX RCBO range provides top and bottom line load compatibility. Standards The Resi MAX range of miniature circuit breakers (MCBs), residual current devices without over current protection (RCCBs), residual current circuit breaker with over current protection (RCBOs), and isolators complies with the latest standards AS/NZS60898-1, AS/NZS61008-1, AS/NZS61009-1, and AS/NZS 60947-3 respectively. The Resi MAX range of switchboards is compliant with AS/NZS61439-3. Reliable material Housing for all devices is made of sturdy, self extinguishing material. Each circuit protection device has lift up terminals with combination head screws. Additional safety is provided with ON and OFF marking in contrasting colours on toggle mechanisms. Time saving The Resi MAX range provides the complete solution for circuit protection. Busbar-compatible RCBOs are equipped with insulated slots and deep bottom cog rail terminals, allowing for a quick fit off. This, along with many other features, ensures Resi MAX saves you time on installation. Compatibility Optimised for SLIM RCBO, the SLIM comb busbar ensures that wiring effort is reduced, making your installation tidy and time/cost effective. Convenience Two in one system New design for easier installation Ease of wiring Compact and light MSW180 Isolator switch Resi MAX symbol The new identification symbol on all Resi MAX products provides peace of mind. The Resi MAX range is 100% suitable for residential applications. Top and bottom line load compatible SLIM RCBO available to save valuable switchboard space by combining the functionalities of an RCD and MCB within 18 mm. (as seen on product) (as seen on packaging) RCBE220/30S MCB4-120 Combination residual Current device SLIM (RCBO) 6 Clipsal.com

Pre assembled Load Centre Customised, pre-assembled Resi MAX system is ready to install Why choose the Resi MAX Pre-assembled Load Centre?* You can configure the load centre specifically for your customers from our extensive range of systems A residential circuit protection system in one complete solution Reduces your installation time on site You re fully covered without the worry of missing components Perfect for multi-dwelling projects Connect customers to their home energy Wiser Link connects your customers to their electricity, gas, solar, and water use anywhere, anytime. This system will also help you achieve points for multi unit residential green building accreditations. Order today 1. Contact your local wholesaler representative for your configurator form 2. Select your plastic switchboard 3. Configure it with a wide range of circuit protection 4. Upgrade your Load Centre with our residential energy management solution 5. Send to your local wholesaler representative 6. Await your quote Once approved, your order will be on its way. Resi MAX offers unrivalled flexibility without compromising on quality. The easier, quicker way to configure your plastic switchboards has arrived. *Minimum order of 50 pre assembled load centres Life Is On Clipsal 7

Arc Fault Detection Device Offer your customers the best protection from electrical fires Every year in Australia there are over 10,000 house fires resulting in death, injury, and millions of dollars worth of property damage. In every building, the electrical installation must be protected against fires caused by electricity. Even a minor electric fault can have serious consequences. With AFDDs you will set new standards for reliable protection against fires caused by electricity. Stay safe with our new AFDD recommended in every home! How electric arcs cause fires An electric arc is a discharge of electricity inside the insulation of an electrical connection or damaged wire. Electric arcs occur in a specific location and set off of a chain of events that can ultimately cause a fire. There are two types of electric arc Parallel arcs, which occur between two different conductors Series arcs, which occur between two parts of the same conductor The fire then spreads to nearby curtains, wall coverings, and furniture. The vicious cycle continues, and a subsequent electric arc catches the burned electrical insulation on fire. 4 5 1 The wire or connection becomes abnormally hot or suffers physical damage. The burned insulation acts as conductor through which current flows, generating even more carbon. 3 2 Over time, a hot spot develops or a pathway is established allowing current to pass between two conductors; as a result, carbon deposits form on the insulation. 8 Clipsal.com

Highlights Preventive protection from electrical fires Reliable coverage of the protection gap Reliable disconnection of the circuit if hazardous arcing faults occur Maximise protection for residential installations and public buildings. Closing the critical protection gap Electrical installation circuits are usually safeguarded by proven protection, including fuse systems, MCBs, and RCDs. These are not suitable for detecting and safely disconnecting serial arcing faults. This protection gap is now being closed with AFDD. Important circuits to protect Bedroom and living room socket circuits Circuits susceptible to damage (surface mounted, outdoor installation, etc.) Ageing circuits where contacts may have broken down or vibrated loose Adding a Clipsal AFDD to a home s circuit protection will offer your customers the best available defense from electrical fires caused by arc faults. For more information head to: clipsal.com/arcdetection Life Is On Clipsal 9

Wiser Link energy metering Smarter energy and solar monitoring Wiser Link energy management assistant is an app based system that allows residential consumers to monitor their electricity, gas, and water consumption behaviours as well as their solar PV production to help reduce their electricity bills. Benefits Achieve points for multi unit residential green building accreditations Easy and fast to install: Mount the 2 DIN rail products, configure the loads, and connect to internet MIP EM5 CT sensors Set alerts to be sent automatically when abnormal events occur (power outage) or when you reach a monthly energy target per load. Compare consumption trends to previous months. All data is stored securely. Display kwh and $ total home energy consumption by meter: Electricity (optional module for gas and water). Display kwh and $ energy consumption by specific area or appliance. For example, air conditioning, kitchen loads, outdoor pool, or hot water. Real time home energy consumption and solar production with detailed graphs. Analyse and download your energy data with daily, weekly, monthly, and yearly graphs. Measure solar PV production in kwh and $ to see how much money your customers are saving.* *Optional feature 10 Clipsal.com

230 series meter boxes Unmatched flexibility, fully compliant Exterior meter boxes act as enclosures for your customers circuit protection products. They offer protection while providing easy access to electrical equipment during maintenance. The Clipsal meter box has been designed with safety and security in mind. The combination of a wide access panel meter enclosure and generous wiring room offer the perfect solution for domestic outdoor locations. NSW/ACT meter box Common features Galvanised steel meter box Overall dimensions H680 x W470 x D279 mm except South Australia meter box Ingress protection rating of IP23* Compliant with local service and installation rules Sliding bracket and lead tie off point Door retaining strap Lockable door Wide meter panel Aesthetic design Sliding bracket Includes sliding bracket and lead tie off point. Suits temporary and permanent Installations Wide meter panel is double hinged: It swings forward or can be fully removed for easy access and wiring Lockable door Door retaining strap Lead tie off point No powder coating Paint with the colour of your choice Door retaining strap to keep door open for convenience during installation and maintenance State based meter boxes Specifically designed for Australian conditions and has a fully compliant solution tailored for the ACT, NSW, QLD, SA, TAS, and VIC. *See technical details Queensland Supplied with neutral and earth bar grid assembly South Australia Supplied with one meter isolator; Din rail with 24 poles capacity Victoria Supplied with a fuse isolator and neutral link Tasmania Supplied with neutral and earth bar grid assembly Life Is On Clipsal 11

Circuit protection technical information Resi MAX consumer switchboard s have been selected to help reference the number of rows and modules per row in each product. For example RMXE108S = 1 row of 08 modules. RMXE312F = 3 rows of 12 modules RMXE108S RMXE112S RMXE118S RMXE212S RMXE312S RMXE108F RMXE112F RMXE118F RMXE212F RMXE312F Resi MAX switchboard 1 row, 8 modules, surface mount Resi MAX switchboard 1 row, 12 modules, surface mount Resi MAX switchboard 1 row, 18 modules, surface-mount Resi MAX switchboard 2 rows, 24 modules, surface-mount Resi MAX switchboard 3 rows, 36 modules, surface-mount Resi MAX switchboard 1 row, 8 modules, flush mount Resi MAX switchboard 1 row, 12 modules, flush mount Resi MAX switchboard 1 row, 18 modules, flush mount Resi MAX switchboard 2 rows, 24 modules, flush mount Resi MAX switchboard 3 rows, 36 modules, flush mount RMXE112S RMXE112F Main switches MSW140 MSW180 SW1100 MSW240 MSW280 SW2100 MSW340 MSW380 SW3100 1P 40 A 240 VAC 1P 80 A 240 VAC 1P 100 A 240 VAC 2P 40 A 415 VAC 2P 80 A 415 VAC 2P 100 A 415 VAC 3P 40 A 415 VAC 3P 80 A 415 VAC 3P 100 A 415 VAC MSW180 MSW280 MSW380 Surge protection devices 920RM/1 Resi MAX surge arrestor 1P Imax=20 ka 920PM Cartridge Imax=20 ka Resi MAX SLIM one module MCB/RCD combinations (RCBO) RCBE206/30S 6 A 1P+N 30 ma C A 4500 A (6 ka with fuse) RCBE210/30S 10 A 1P+N 30 ma C A 4500 A (6 ka with fuse) RCBE216/30S 16 A 1P+N 30 ma C A 4500 A (6 ka with fuse) RCBE220/30S 20 A 1P+N 30 ma C A 4500 A (6 ka with fuse) RCBE225/30S 25 A 1P+N 30 ma C A 4500 A (6 ka with fuse) RCBE232/30S 32 A 1P+N 30 ma C A 4500 A (6 ka with fuse) Residual current devices (RCCB) 920RM/1 RCBE220/30S 920PM cartridge RCD240/30 RCD263/30 RCD440/30 RCD463/30 2P 40 A 30 ma AC 2P 63 A 30 ma AC 4P 40 A 30 ma AC 4P 63 A 30 ma AC RCD240/30 RCD440/30 12 Clipsal.com

Miniature circuit breakers MCB4 106 MCB4 108 MCB4 110 MCB4 116 MCB4 120 MCB4 125 MCB4 132 MCB4 140 MCB4 150 MCB4 163 1P 6 A C 240 V 4500 A (6 ka with fuse) 1P 8 A C 240 V 4500 A (6 ka with fuse) 1P 10 A C 240 V 4500 A (6 ka with fuse) 1P 16 A C 240 V 4500 A (6 ka with fuse) 1P 20 A C 240 V 4500 A (6 ka with fuse) 1P 25 A C 240 V 4500 A (6 ka with fuse) 1P 32 A C 240 V 4500 A (6 ka with fuse) 1P 40 A C 240 V 4500 A (6 ka with fuse) 1P 50 A C 240 V 4500 A (6 ka with fuse) 1P 63 A C 240 V 4500 A (6 ka with fuse) MCB4-120 Busbar and accessories technical information SLIM comb busbars for SLIM RCBO Poles Phase modules RMXPH105 1P+N 5 modules RMXPH112 1P+N 12 modules RMXPH124 1P+N 24 modules RMXPH312 3P+N 12 modules RMXPH324 3P+N 24 modules RMXPE110 1P+N End cap (set of 10) RMXPE310 3P+N End cap (set of 10) RMXPT120 Teeth cover (set of 20) RMXPC1 1P+N Cable connector (set of 4) RMXPC3 3P+N Cable connector (set of 4) Note: Connectors are not supplied with the comb busbar need to be ordered separately. Insulated comb type busbars Poles Phase Current rating 4BB1/24 24 1 80 A 4BB1 56 1 80 A 4BB2 56 2 80 A 4BB3 56 3 80 A Note: Connectors are not supplied with the comb busbar need to be ordered separately. RMXPH112 RMXPT120 4BB1 RMXPC1 RMXPE110 Cog rail busbars Poles Phase Current rating 4BB4/12 12 1 80 A 4BB4/18 18 1 80 A 4BB4/57 57 1 80 A 4BB4/12/2 12 2/1+N 80 A 4BB4/18/2 18 2/1+N 80 A 4BB4/57/2 57 2/1+N 80 A 4BB4/12/3 12 3 80 A 4BB4/18/3 18 3 80 A 4BB4/57/3 57 3 80 A 4BB4/12/2 Life Is On Clipsal 13

Accessories technical information Cog rail busbar end caps 4BBTC1 4BBTC3 Phase Busbar 1 phase end cap Busbar 2 phase, 3 phase end cap 4BBTC1 Insulated comb type busbar connector 4BB5 Terminals 27060 4XT3 Phase Busbar connector to suit up to 25 mm conductors Phase Expanding 35 mm terminal to suit one module MCBs and switches 3 x 16 mm neutral link to suit termination of RCD neutrals 4BB5 27060 4XT3 Pre assembled load centre technical information For more details, visit: clipsal.com/preassembled Arc Fault Detection Device technical information For more details, visit: clipsal.com/arcdetection Wiser Link technical information Wiser Link EER70600 Wiser Link MIP (Internet communication module) EER71000 Wiser Link EM5 Kit (Energy meter + 5 CT sensors) EER71200 Wiser Link EM5 Extra CT sensors (set of 5) 14 Clipsal.com

Meter box technical information Tasmania 230DRAT 230SMT South Australia 230DRAS1Ml 230DRAS2MI 230DRAS3 230MIC163 230MIC363 230DRASL 21 module switchboard; Dimensions: H680 x W470 x D280 mm 21 module switchboard; Dimensions: H860 x W464 x D282 mm 24 module switchboard and space for a single meter complete with meter isolator MCB 1P 63 A 6k A; Dimensions: H612 x W470 x D260 mm 24-module switchboard and space for multiple meters with meter isolator MCB 1P 63 A 6k A; Dimensions: H805 x W505 x D260 mm 30 module switchboard and space for multiple meters; Dimensions H590 x W612 x D260 mm Meter isolator MCB 1P 63 A C curve 6 ka enclosure and lock off device Meter isolator MCB 3P 63 A C curve 6 ka enclosure and lock off device Key locking unit Queensland 230DRAQ 230DRAQTP New South Wales 230DRANS 230DRANSAP 230DRANSAD 230DRANSAK 21-module switchboard and space for a single meter box; Dimensions: H680 x W470 x D280 mm 21 module switchboard and space for a single meter box (suitable for temporary supply AS/NZS3012 compliant); Dimensions: H680 x W470 x D280 mm NSW meter box with black laminated meter panel; Dimensions: H680 x W470 x D280 mm Spare meter panel for NSW meter box; Meter panel: 630 mm x 440 mm Spare door; not powder coated Spare kit; sliding bracket and lead tie off point Victoria 230DRAVL 230MV 230PBV 230DRAVAD 21 module switchboard and space for a single meter box with service fuse lock; Dimensions: H680 x W470 x D280 mm Meter enclosure only; Dimensions: H430 x W470 x D280 mm Bracket for temporary power service pole, suits 230DRAVL Note: A pipe and bracket are required for temporary power service Accessory Door; Assembly 230DRA series Surface mount moulded enclosures Plastic enclosures To suit DIN rail mounted equipment, available in White Electric (WE) only. 4CC1 WE 1-module, surface mount; Dimensions: H133 x W35 x D69 mm 4CC2 WE 2-modules, surface mount; Dimensions: H133 x W53 x D69 mm 4CC3 WE 3-modules, surface-mount; Dimensions: H133 x W70 x D69 mm 4CC4-WE 4-module, surface-mount; Dimensions: H153 x W88 x D69 mm Life Is On Clipsal 15

The complete residential solution Clipsal.com/residentialprotection Schneider Electric (Australia) Pty. Ltd. 33-37 Port Wakefield Road, Gepps Cross, South Australia, 5085 PO Box 132, Enfield Plaza, South Australia, 5085 Consumer Support Enquiries Phone: 1300 669 925 Website: clipsal.com/contactus National Customer Care (trade only) Phone: 1300 369 233 2016 Schneider Electric. All Rights Reserved. Schneider Electric Life Is On is a trademark and the property of Schneider Electric SE, its subsidiaries, and affiliated companies. 998 19894380_AU