Hood assembly with bib. Hood assembly, Coated, with bib. Hood assembly with collar. Hood assembly, coated, with collar

Similar documents
Product Numbers & Ordering Information

Product Numbers & Ordering Information

Powered Air Purifying Respirator (PAPR) SAFETY, COMFORT, FLEXIBILITY. Compact Air 200 Series PAPR No Worry, No Guesswork

Industrial Respiratory Protection Systems

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

Chargebuster Ion Gun Installation, Operation and Maintenance

Reinventing the Powered Air Purifying Respirator in Nuclear Trip McGarity of Frham Safety Products, Inc. Ronnie Dunne of Gentex Corporation

Dräger X-plore 8000 Powered Air-Purifying Respirator (PAPR)

OWNE R S MA N UA L. Made in USA. September 2015

Honeywell Safety Products

Carbon Monoxide Monitor and Retrofit Carbon Monoxide Monitor Kit W-2808/37027

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

AMC-CD2. Human Occupancy Detector INSTRUCTION MANUAL. Please read these instructions completely and carefully before starting.

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

RK/ RK Oxygen Detector Operator s Manual

REVOLUTIONARY RESPIRATORY PROTECTION CLEANSPACE2 NIOSH APPROVED TC-21C

Industrial Vacuums, Inc

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

MST MODEL S1 AIRLINE "CO" MONITORING AND LOW PRESSURE WARNING SYSTEM MANUAL

DESIGNED BY FIRE FIGHTERS FOR FIRE FIGHTERS.

MRS-6 Maxi-Guard II. Model: C , 12, 13, 14 OPERATION SERVICE PARTS CARE. Revised 2/02

REVOLUTIONARY RESPIRATORY PROTECTION CLEANSPACE2 NIOSH APPROVED TC-21C-0957

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

GASGUARD Cl 2. Chlorine Sensor OPERATING & INSTALLATION MANUAL

Chargebuster Ion Gun Installation, Operation and Maintenance

C-Box 100, H-Box 200 & H-Box 500

PNEUMATIC VACUUMS ATEX Certified For Hazardous Locations OPERATING MANUAL

PORTER INSTRUMENT COMPANY, INC. 245 TOWNSHIP LINE RD. P.O. BOX 907 HATFIELD, PA USA [215] / FAX [215]

Bench Top Ionizer Installation, Operation and Maintenance

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC015 - AC016 - AC018

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

WATER CLAW SUB-SURFACE FLOOD EXTRACTION TOOL AC016 - AC018. Water Claw 4282 South 590 West Salt Lake City, UT FAX

User s Manual and Operating Instructions

Design Manual Installation Operation Maintenance

MST, INC. MODEL 2002 OXYGEN MONITOR (AMBIENT-TYPE) OWNER S MANUAL

User s Manual and Operating Instructions

Cleanshield HEPA 550 Owner's Manual

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Bag-In-A-Box Oil System Instruction Manual Model #2257EX & 2257DX For Export Bag-In-Box Pumps Made After March 2003

48 MaxxAir Portable Evaporative Cooler Owner s Manual

GASGUARD NH 3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

Desiccant / Pump Dehumidification System. Model Operating Manual

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Mini rad-d User's Manual - February 22, 2010

2001 Smith Eastern Corporation

USER MANUAL IMPORTANT

UV PRO 15, ozone generator instruction manual ****IMPORTANT****

Owner s Manual Hydro-X Vacuum Pac

14 Upright Vacuum with HEPA Filter & Dual Power

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

Service Parts, Kits and Accessories

INSTALLATION AND OPERATING INSTRUCTIONS FOR THE VEHICLE-MOUNTED RADIATION DETECTION SYSTEM

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Operating Instructions

RK Carbon Monoxide Transmitter Operator s Manual

Milk Coolers Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

Installation Instructions / Warranty

CANISTER VACUUM MODEL SC-19

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

18 MaxxAir Portable Evaporative Cooler Owner s Manual This Manual covers the EC18DVS MaxxAir Portable Evaporative Cooler.

Please Read and Save These Instructions.

User s Manual and Operating Instructions

MERCURY HD-22 AUTOSCRUBBER Safe Operations

RK-05 Carbon Monoxide Detector Operator s Manual

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

Intrinsically Safe Transmitters, Option Code 2n

Installation/Operation Instructions COMP-COOL50/COMP-COOL50P 50 CFM COMPONENT COOLERS

Zeus Extreme Owner's Manual

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

V LPM Desiccant Air Dryer Installation and Operation Manual

Installation Instructions / Warranty

RK/ RK Carbon Monoxide Detector Operator s Manual

M-11 Series. Installation and Service Manual

Static Eliminators. Overhead Ionizing Blower Model IN5130. Instruction Manual

RK-02 Multi Point Detector Operator s Manual

OPERATING INSTRUCTIONS

OI-2400-DOCK Multi Gas Docking Station. Operation Manual trevision 2.2w

D-TEK Select. Refrigerant Leak Detector

ASSEMBLY INSTRUCTIONS

ASSEMBLY INSTRUCTIONS

Installation Instructions / Warranty. Metris 31060XX XX XX1

Condensate Pump. Installation and Safety Instructions CP-16 CP

IN020 Rev F Page 1 of 8

SSS BPV- 40 Backpack Vacuum

Installation Guide

This instruction manual explains the use of three models listed on the left.

Global Water Instrumentation, Inc.

MC MC MC MC MC833130

MGC Dock User s Manual

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Safe Operation Manual. Honeywell IQ Force Gas Detector

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE. Visit our Website for more information on this product.

OWNER'S MANUAL IMPORTANT: READ OWNER'S MANUAL CAREFULLY BLACK CAT FOR YOUR CONVENIENCE, RECORD THE FOLLOWING IMPORTANT INFORMATION MODEL:

Transcription:

Honeywell North PA700 Series Powered Air Purifying Respirator (PAPR) The Honeywell North PA700 Series is a belt mounted PAPR approved by the National Institute of Occupational Safety and Health (NIOSH). It is an all-new, integrated respiratory system that has been engineered to be easy to assemble, operate and maintain. Protection Type This respirator is ideally suited for applications in which non-powered air purifying respirators are not practical or in which a higher protection factor is required, yet where the atmosphere is not immediately dangerous to life and health (IDLH) and where there is an oxygen content of at least 19.5%. When used together with Honeywell North filter cartridges and Honeywell North facepieces or head covers, the PA700 Series PAPR provides respiratory protection against most dusts, fumes, mists, particulate radionuclides and radon progeny attached to dusts, fumes and mists. Certifications The PA700 series PAPR meets the requirements of NIOSH CFR 84 when assembled from components listed on the NIOSH approval label included with the product. For detailed information on hood/headgear assemblies, see the user manuals for those products. Refer to the NIOSH approval labels provided with the PA700 Series blower assembly and filter cartridges for specific NIOSH approval numbers. Assigned Protection Factors The PA700 Series PAPR is for protection from particulates where (i) the concentration does not exceed the Permissible Exposure Limit (PEL) as determined by the Assigned Protection Factor (APF) of the headpiece, (ii) the concentration is below the contaminant s Immediately Dangerous to Life or Health (IDLH) level, and (iii) there is sufficient oxygen in the work environment according to the OSHA Regulation 29 CFR Section 1910.134 or CSA Standard Z94.4 requirements. See the table below for more information regarding the APF. HEADPIECE SERIES P/N DESCRIPTION SWPF TEST RESULTS* PA111 Hood assembly with bib Primair 100 Series PA121 PA131 PA141 Hood assembly, Coated, with bib Hood assembly with collar Hood assembly, coated, with collar >10,000 fit factor APF = 1000 Primair 200 Series PA201E01 PA231E01 Hood assembly with hard hat Hood assembly with hard hat and flame-resistant covers *All hoods tested with PA700 Series PAPR. Testing conducted by Honeywell Industrial Safety. Note: Because of the positive pressure created by the flow of air, PAPRs have a higher protection factor. The respirator manufacturer must have evidence that testing of these respirators demonstrates performance at a level of protection of 1,000 or greater to receive an Assigned Protection Factor (APF) of 1,000. This level of performance can best be demonstrated by performing a Workplace Protection Factor (WPF) or Simulated Workplace Protection Factor (SWPF) study or equivalent testing. If such testing is absent, helmets/hoods are to be treated as loose-fitting facepiece respirators, and should receive an APF of 25. For more information www.honeywellsafety.com Honeywell Safety Products USA 900 Douglas Pike Smithfield, RI 02917 Phone: 800.873.5242 www.honeywell.com CANADA 10550 Parkway Boulevard Anjou, Quebec H2W 2R2 Phone: 800.873.5242

Major Components Blower The PA710 blower is the heart of the PAPR. It draws contaminated air through the filter cartridge and pushes a continuous flow of clean air to the user. Every system is programmed and calibrated at the factory to provide a steady and measured flow of air, even as the filter cartridge becomes saturated with contaminants. The blower also includes an intelligent alarm system that alerts the user when the battery charge or airflow level is low. The system uses audible, visual and vibratory notifications to effectively and clearly communicate alarm status, even in loud, harsh conditions. Battery and Charger The PA710 blower is powered by a rechargeable lithium-ion battery pack. The PA720 battery pack can power the PAPR system for an entire 8-hour work shift*. It slides and locks into the blower unit, greatly reducing the risk that it will fall and break. The PA720 battery pack also features an on-board, state-ofcharge display, which allows the user to evaluate the amount of remaining charge in the pack, without installing it into the blower. The PA724 smart-charger system can re-charge a fully depleted battery in approximately 4.5 hours. In addition to charging, it continuously monitors the health of the battery pack and can alert the user to a potential problem via an LED display panel. *Typical expectations based on laboratory testing. Actual battery run time and battery service life is dependent on many factors including working environment, charging conditions, filter cartridge type and headpiece type. Belt Assembly The PA700 series belt assemblies have been designed with all-day comfort in mind. The ergonomic shape and choice of materials help distribute the weight of the PAPR evenly on the worker s body and keep it from slipping. The optional comfort pad can be snapped on, providing even more cushioning support. Breathing Tubes The all-new PA031 and PA031L breathing tubes work exclusively with the new PA700 series PAPR system. They feature simple, twist and lock connectors, a light-weight and highly flexible hose material and a swiveling connection to prevent the hose from twisting or binding. Cartridges & Filters The PA700 Series PAPR is approved for use with the PA7HE HEPA filter cartridge. The cartridge securely installs into the blower with a simple ¼-turn twist and lock system. It is 99.97% efficient and exceeds NIOSH requirements for service life.

Ordering Information A complete NIOSH approved powered air purifying respirator includes a blower, battery pack, battery charger, belt, flow meter, breathing tube, filter cartridge and headpiece. To simplify the ordering process, the major components of the PA700 Series PAPR can be purchased as a kit. Unless otherwise noted, breathing tubes, filter cartridges, filter cartridge covers and headpieces are sold separately. STEP 1: SELECT YOUR PA700 SERIES PAPR BLOWER ASSEMBLY PA701HE PA701 PA701D* Assembly includes blower, battery, battery charger, comfort pad, and nylon belt and free starter kit (P100 HEPA filter and optional filter cover) Assembly includes blower, battery, battery charger, comfort pad, and nylon belt Assembly includes blower, battery, battery charger, comfort pad, and PVC belt STEP 2: SELECT YOUR HOOD OR FACEPIECE PA100 Series Head Covers & Hoods PA200 Series Hoods Half Masks Full Facepieces Welding Full Facepieces PA111 PA201E01 770030S, M, L* 760008A, S* 760008AW, SW* PA121 PA231E01 550030S, M, L* 54001, S* 54001W, SW* PA131 PA141 PA101S, M* STEP 3: SELECT YOUR BREATHING TUBE PA031 Straight Breathing Tube for Primair Hoods, 34" PA031L Straight Breathing Tube for Primair Hoods, 40" PA034* Y-Shape Breathing Tube for tight fitting facepieces, 34" PA034L* Y-Shape Breathing Tube for tight fitting facepieces, 40" STEP 4: SELECT YOUR CARTRIDGE OR FILTER PA7HE P100 HEPA** Filter NOTE: Cartridge/Filter Combinations pending NIOSH approval STEP 5: SELECT YOUR ACCESSORIES PA75A1 Comfort Pad PA71A1 Filter Cover/Shower Cap CA113 Fabric Cover for straight breathing tubes (for use with PA031 and PA031L) CA114* Fabric Cover for Y-shape breathing tubes (for use with PA034* and PA034L*) 7003 Refresher wipes, with alcohol 7003A Refresher wipes, alcohol free 80995 Cleaner/Sanitizer, 10oz bottle (not available in Canada) *Pending NIOSH approval **HEPA (High Efficiency Particulate Air-Purifying), 99.97% minimum filter efficiency for all particulates.

Technical Specifications COMPONENT AND ATTRIBUTE Operating Conditions Temperature Humidity Altitude Ingress Protection Explosive Environments Storage Conditions Temperature Blower Housing Material Weight Air-Flow (loose-fit configurations) Air-Flow (tight-fit configurations) Alarms Motor Life Noise Level Battery Pack Materials Weight Chemistry Capacity Run-time SPECIFICATION +10 F (-12 C) to +118 F (+48 C) (Note: A low-battery alarm will be triggered if the internal temperature of the battery reaches 48C) 20 90% R.H. (non-condensing) 0 10,000 ft above sea level IP65 with battery, breathing tube, filter cartridge and cartridge cover installed The PA700 series is not suitable for potentially explosive environments. Daily: -4 F (-20 C) to +95 F (+35 C) Ideal: 40 F (5 C) to 68 F (20 C) PC/ABS 1.77lbs (805g) 7.2CFM (205lpm) Nominal Default 7.8CFM (220lpm) Nominal Medium 8.3CFM (235lpm) Nominal High 5.5CFM (155lpm) Nominal Audible, Visual and Vibratory (See user-instructions for details regarding alarm triggers and sequencing) >10,000 hours (est.) <75 dba (average measured at the ear) Housing: PC/ABS Latch: Nylon Gasket: Open-cell silicone foam 0.9lbs (410g) Lithium-Ion 10.9V, 6700mAh, 73wH 8hr (average)* Safety Service Life Shipping Short circuit/overload/over voltage/over temperature protection Minimum 500 charge/discharge cycles while maintaining at least 70-80% of the original capacity* UN38.3 certified for air-transportation (Always consult a logistics professional for information regarding proper shipment of li-ion battery packs)

Battery Charger Time to full charge Display Power Input Requirements Breathing Tubes Length PA031: 34 PA031L: 40 Materials Belt and Comfort Pad Materials Adjustment Range Filter Cartridge Shell Material Particulate Filter Media <4.5 hours in ideal charging conditions (See user-instructions for further details) Real-time battery charge and health monitoring (See user-instructions for further details) Power Supply: AC 100-240V, 1.5A 50-60Hz Single-bay Charger: DC 19.0V, 2.37A Connectors: ABS Corrugated Hose: Polyurethane O-Rings: Buna-N, Silicone Straps: Woven Nylon Back/Hip Support: Thermoplastic Polyurethane, PC/ABS Comfort Pad: Closed Cell Polyethylene Foam, Nylon Fabric (TPE Coated) Hardware: Acetal 28 60 (71-152cm) circumference Polystyrene Hydrophobic, high efficiency particulate media 99.97% efficient *Typical expectations based on laboratory testing. Actual battery run time and battery service life is dependent on many factors including working environment, charging conditions, filter cartridge type and headpiece type. Additional Ordering Information SKU DESCRIPTION QTY/ LENGTH IN (CM) WIDTH IN (CM) HEIGHT IN (CM) WEIGHT LB (KG) CASE PA700 PAPR Assemblies PA701HE PAPR Starter Kit w HEPA 1 - - - 6.0 (2.7) Breathing Hoses PA031 Breathing Tube, Loose Fit 10 19.0 (48.2) 9.5 (24.1) 9.5 (24.1) 3.5 (1.6) PA031L Breathing Tube, Loose Fit, Long 10 19.0 (48.2) 9.5 (24.1) 9.5 (24.1) 4.0 (1.8) Filter Cartridges PA7HE HEPA Filter Cartridge (5/Box) 20 11.0 (27.9) 11.0 (27.9) 8.5 (21.6) 11.0 (5.0) Accessories PA75A1 Comfort Pad - - - - - PA71A1 Cartridge Cover, Sm - - - - - Replacement Components PA710 PA700 Series Blower (blower-only) 5 14.5 (36.8) 9.5 (24.1) 11.0 (27.9) 12.0 (5.5) PA720 Battery Pack, Standard Capacity 1 6.5 3.0 2.5 1.3 (0.6) PA724 1-bay charger kit, N. America 1 - - - 1.3 (0.6) PA722-3A Power Kit, 1-bay charger, N. America 1 - - - 0.8 (0.4) PA751 Standard belt, woven nylon - - - - - CA132 Air Flow Meter 1 No shipping carton specified for this item Note: Additional packaging information pending.

Limited Warranty HONEYWELL INDUSTRIAL SAFETY warrants the Honeywell North Primair 700 Series PAPR to the original owner to be free from defects in materials and workmanship for a period of one (1) year from the date of original shipment from Honeywell s factory. Honeywell s obligation under this warranty will be, at Honeywell s option, to repair or replace without charge the Honeywell North Primair 700 Series PAPR or any of its components found by Honeywell to have been defective during the warranty period, under the following terms: 1) The warranty claim is made (i) by the owner who purchased the Honeywell North Primair Series 700 PAPR new from Honeywell or an authorized Honeywell Distributor, and (ii) not more than three (3) months after the end of the warranty period. 2) The Honeywell North Primair 700 Series PAPR or component is found by Honeywell to have been defective in normal use and service during the warranty period of one (1) year from the date of purchase by the owner. 3) The Honeywell North Primair 700 Series PAPR or component is returned freight prepaid to Honeywell, either to its factory or to a Honeywell authorized service center and is thereafter returned to the owner freight collect. 4) This warranty does not apply (i) to any Honeywell North Primair 700 Series PAPR or component found by Honeywell to have become defective as a result of any accident, alteration, misuse, abuse, or servicing with parts not approved by Honeywell; (ii) to deterioration or aging of any component made of rubber or other elastomer since such components can be adversely affected by undue exposure to heat, sun, water, chemicals, ozone or other deteriorating elements; or (iii) facepiece lens, compressed-air cylinders and parts that become defective through normal use. The decision as to what constitutes normal use shall be made solely by HONEYWELL INDUSTRIAL SAFETY. 5) To maintain this warranty, the purchaser must perform maintenance and inspections as prescribed in the User s Instructions which shall include prompt replacement or repair of defective parts, and replacement of parts per the maintenance schedule as prescribed in the User s Instructions. THE OWNER ASSUMES ALL OTHER RISKS, IF ANY, SUCH AS THE RISK OF ANY DIRECT, INDIRECT OR CONSEQUENTIAL LOSS OR DAMAGE ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE PRODUCT. SERVICING HONEYWELL RESPIRATORS WITH PARTS NOT APPROVED BY HONEYWELL WILL VOID THIS WARRANTY AND NIOSH APPROVAL FOR THE RESPIRATOR. THIS WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED AND MAY NOT BE VARIED OR EXTENDED EXCEPT IN WRITING BY AN AUTHORIZED OFFICIAL OF HONEYWELL INDUSTRIAL SAFETY.