MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

Similar documents
Mini-Split Air Conditioners and Heat Pumps

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications


Auto Louver : Up/Fown Auto Mode Minimum Heat Mode Economy Mode

Residential and Light Commercial Ductless Systems Catalog

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Hi-spec Design model. Photo : LT series

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS. Now Only One Unit Required for Initial Start-up

LIFESTYLE R A NGE W A L L M O U N T E D N EW STYLISH, SLIM AN D ELEGANT 5 YEAR F U LL P A R TS & LABOUR W A RRANTY

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

K sin. Mini Split Air Conditioners and Heat Pump

Mini-Split Air Conditioners and Heat Pumps

A single answer for multiple zones.

A single answer for multiple zones.

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

Mini-Split Air Conditioners and Heat Pumps

DUCTLESS FULL LINE CATALOG

Haier America 1800 Valley Road, Wayne, NJ haierductless.com. Haier Ductless Air / 2015

FREE JOINT MULTI. Multi-Zone Mini Split Air Conditioner. Ver quietside.com

IT'S HARD TO STOP A TRANE

READ ONLY. American Standard Ductless Systems Product Catalog. A Comfortable, Convenient Solution Built To A Higher Standard.

Geniuses at work. Residential Mini Splits

Lennox Mini-Split Systems Year-Round Comfort and Performance

DUCTLESS MINI-SPLITS LIGHT COMMERCIAL AND MULTI-ZONE SYSTEMS PRODUCT CATALOG ALEGRIA ALEGRIA SERIES ALEGRIA

DUCTLESS SPLIT SYSTEMS

DUCTLESS SPLIT SYSTEMS AIR CONDITIONERS HEAT PUMPS

FUJITSU FLOOR CONSOLES FUJITSU

L E N N O X MINI-SPLIT SYSTEMS THE SOLUTION THAT WORKS WHERE OTHERS WON T.

DESIGN & TECHNICAL MANUAL

The New Generation of Heat Pumps

DESIGN & TECHNICAL MANUAL

comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps

ductless mini-splits light commercial and multi-zone systems product catalog ALEGRIA ALEGRIA

Mitsubishi System Technologies:

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Mini Split Air Conditioners and Heat Pump

Ductless Series Variable Speed Split Systems

Single and Multi-Zone Ductless Split Systems

2 &3-4 Head Multi System

InverterFlex SERIES InverterFlex Systems condition up to five rooms

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

DAIKIN 17 SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEM S. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DSS SERIES SINGLE ZONE INVERTER WALL-MOUNT SYSTEMS. Up to 17 SEER Up to 9.0 HSPF / Up to 11.5 EER HEAT PUMP AND COOLING ONLY

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Mini-Split and Multi-Zone Air Conditioners and Heat Pumps. Residential/Light Commercial Catalog 2016

Daikin 19 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

LV SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

Light commercial range. Passion at work

JUNE & 3-4 Head Multi System

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

DAIKIN 19 SERIES SINGLE-ZONE HEATING & COOLING SYSTEMS

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Haier Ductless Product Brochure

Breeze A revolution in room cooling.

-20 C 11 HSPF 23 SEER WALL-MOUNTED HEAT PUMPS. 10 years* *See details on the back SINGLE ZONE MULTI-ZONE (UP TO 5 ZONES) descair.

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

DESIGNER RANGE SLEEK, SLIMLINE DESIGN HIGH ENERGY EFFICIENCY BACKED BY A 5 YEAR FULL PARTS & LABOUR WARRANTY

DESIGN & TECHNICAL MANUAL

HEAT PUMPS. Efficient Comfort For Every Season

THE WORLD S MOST EFFICIENT HEAT PUMP

"I'm a Daikin Comfort Pro"

Daikin 15 SERIES SINGLE ZONE HEATING & COOLING SYSTEMS 15 SERIES WALL MOUNTED UNITS Up to 15 SEER / Up to 8.2 HSPF / Up to 12.

SERIES. Ductless Split Comfort Systems. Mark of Superior Quality ADVANCED TECHNOLOGY ENERGY SAVINGS ECO-FRIENDLY NEW RESIDENTIAL LINE

DESIGN & TECHNICAL MANUAL

Air Conditioning & Heating. Ductless Heating & Cooling Systems

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

CANADA S #1 SELLING BRAND OF DUCTLESS. mitsubishicomfort.ca

Mini-Split Single-Zone and Multi-Zone Air Conditioners and Heat Pumps. Residential Catalog 2018

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

QUATERNITY SERIES SINGLE ZONE HEATING & COOLING SYSTEMS

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

XLTH Series: Extra Low Temperature Heating Down to -15 F

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

DAIKIN FHQ SERIES HEAT PUMP & COOLING ONLY SYSTEMS. CEILING-SUSPENDED CASSETTE Up to 18.0 SEER / Up to 10.0 HSPF Up to 14.0 EER

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

COMFORT FOR LIFE DUCTLESS WALL-MOUNTED

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Product Rebates INDIANA

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

Energy-saving operation

LG Comfort Solutions. Comfort Solutions You Never Thought Possible

DESIGN & TECHNICAL MANUAL

Transcription:

MINI-SPLIT HEATING AND COOLING SYSTEMS FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS 3

TABLE OF CONTENTS QUIETLY REVOLUTIONIZING ENERGY-EFFICIENT HOME COMFORT. FEATURES Mini-Splits Defined... 4 Individual Zoning... 6 Comfort Solution... 8 Energy Efficient... 9 Comfort & Convenience... Applications... FGLair App... WiFi Selection Guide... 3 XLTH Story... 4 Feature Explanation... 5 System Feature Summary Table... MODEL LINEUP and Model Table... 8 SINGLE-ZONE MINI-SPLITS Wall Mount... 0 Floor Mount... 3 Compact Cassette... 34 Slim Duct... 36 Universal Floor/Ceiling... 38 Ceiling Suspended... 38 Large Cassette... 40 MULTI-ZONE MINI-SPLITS Overview... 4 Units Wall Mount... 46 Slim Duct... 48 Compact Cassette... 50 Floor Mount... 5 Units Multi-Zone (-4 Zones)... 54 XLTH Multi-Zone (-3 Zones)... 56 Flex-Zone (-8 Zones)... 58 Branch Boxes... 60 Piping... 6 Allowable Combinations... 64 ACCESSORIES Descriptions... 67 Compatibility Chart... 69 MISCELLANEOUS Line Set Length Chart... 70 Model Nomenclature... 70 3

FEATURES FUJITSU MINI-SPLITS: YEAR-ROUND, WHOLE-HOME OR BUSINESS ENERGY EFFICIENT HEATING AND COOLING WHAT IS A MINI-SPLIT? Halcyon systems eliminate the need for a basement or atticlocated evaporator unit and bulky ductwork by using thin copper tubing that pumps refrigerant directly to discreet wall mounted or concealed units inside. Even more remarkable, this same unit works in reverse in winter, absorbing heat from the outside air and moving it indoors to heat your home. The result? Efficient cooling and heating for yearround, whole-house comfort in most climates. Available in numerous mix-and-match capacities and configurations, there s a Halcyon mini-split system for even the most difficult to heat and cool areas. HOW DOES A MINI-SPLIT WORK? Like your refrigerator, heat pumps use electricity to pump refrigerant and transfer heat from one space to another. When we transfer heat from within our home to the outdoors, we call it air conditioning. Conversely, when we transfer heat from the outdoors to within the home, we call it a heat-pump. HEAT PUMPS PROVIDE HEAT WHEN IT IS COLD Because refrigerant is naturally much colder than outdoor temperatures even on a very cold day, it actually absorbs heat from outdoors, and transfers the heat it absorbs outside to within your home. The refrigerant s physical properties do this naturally. We use efficient compressors to pump refrigerant via small copper tubing from outdoors to indoors. Because we move the heat rather than create it (as electric baseboard or resistant heat does), we can deliver up to 4 times the heat for the energy we consume as baseboard heat! AIR CONDITIONERS PROVIDE COOLING WHEN IT S WARM Come spring and summer, simply reverse the process and put the same system into cooling mode and transfer heat from indoors to the outside. For many climates, the advanced technology that goes into these units creates a far more cost effective alternative to either gas or oil-fired units for heat, or a central ducted system for air conditioning. Fujitsu s full mini-split line up are heat pumps, which provide both heating and cooling. condenser condenser BASIC HEAT PUMP CONFIGURATION Heat In compressor evaporator expansion valve BASIC AIR CONDITIONER CONFIGURATION Heat Out compressor evaporator expansion valve Heat Out Heat In WALL MOUNT UNIT SLIM DUCT UNIT ELECTRIC HEATERS VERSUS HEAT PUMPS unit Refrigerant lines, electric, drain unit Unit Can Be Showcased... Wall mounted units eliminate the need for ductwork, mount high on a wall and deliver all of the cooling and heating needed. Air supply grille...or Hidden Slim Duct units are mounted above a ceiling or in a framed enclosure below a ceiling, so only the grilles show for a clean look. They require minimal ductwork. Air return grille An electric heater converts electricity directly to heat, and if we assume that the heat loss is zero, the output from one kilowatt input is one kilowatt or 3,400 BTU and the EER is 3.4. *EER (Energy Efficiency Rating) = Rated BTU capacity divided by total kw input. Heat pumps are more efficient than some other forms of heating because heat pumps do not actually create heat - they just move it from one place to another. For example, the output of an efficient EER heat pump is almost triple that of an electric heater. 4 5

FEATURES INDIVIDUAL ZONING: PERSONALIZED WHOLE-HOME COMFORT Halcyon HFI Systems are some of today s most advanced forms of heating and air conditioning. One outdoor unit can operate up to 8 indoor units simultaneously. Fujitsu s HFI Systems are super quiet as well as highly energy efficient. This symbol denotes indoor units that can be used in single OR multi-zone applications Each indoor unit can be operated independently via remote control Choose from a variety of indoor unit styles Provide both heating and cooling (not simultaneously) High energy efficiencies Quiet operation 8, 4, 36,000 BTUh SLIM DUCT Mounted in a ceiling or in a framed enclosure below a ceiling. They use minimal ductwork and remain very energy efficient. Concealed and out of sight Look of central air with the efficiency of a mini-split Less ducts = higher efficiency WALL MOUNTED They mount high on a wall, out of sight and do not require ductwork, increasing energy efficiency. Quiet operation Easy maintenance High delivered efficiency means lower utility bills FLOOR MOUNTED Floor mount systems are ideal for residential radiator replacements or any room with limited upper wall space,like a kitchen or sunroom. Compact size fits easily under a standard window Features twin airflow for improved heat delivery and help those cold feet. Designer wireless remote control COMPACT CASSETTE Cassettes are extremely discreet, with only the grille showing in the ceiling. They use the latest fan technology to distribute the conditioned air evenly. Wired remote control (wireless is optional) Powerful turbo fan operation Fits into a standard x ceiling grid Shown here is a 3-zone system using outdoor unit AOU36RLXFZ. 6 7

FEATURES A SOLUTION FOR ALL OF YOUR COMFORT NEEDS ENERGY EFFICIENT: THE SMART CHOICE IN COMFORT DUCTLESS TECHNOLOGY Don t waste money cooling and heating the ducts in your walls and attic. Fujitsu systems are ductless, meaning they install easily and won t take up valuable closet space. Since mini-splits have little to no ducting, they forego those energy losses typically associated with central forced-air systems. Duct losses in a central air system can easily account for more than 30% of energy consumption, especially if the ducts are not sealed tight or in an unconditioned space such as an attic or crawlspace. CENTRAL AIR SYSTEM VERSUS FUJITSU HFI QUAD ZONE Thick black lines represent ducts of a central air system. Red lines represent miniducts of a Fujitsu Quad Zone Slim Duct System. As much as half of the energy used in your home goes to heating and cooling. So, making smart decisions about your home s heating and air conditioning system can have a big effect on your utility bills and your comfort. WHERE DOES MY MONEY GO? The high energy efficiencies of Halcyon systems slash utility bills by up to 5%. If your average annual utilities are $4,00, Fujitsu can save you up to $,050 annually or $,500 in yrs!* Refrigerator Dishwasher Washer/ Dryer Water Heater % 6% 5% 3% 50% Heating & Cooling WHOLE HOME OR BUSINESS COMFORT *Savings may vary based on model selected, hours of operation and geographical location. Example given based on 33-SEER system versus 4-SEER system. Lighting % Fujitsu s Halcyon HFI systems provide home and business owners just the right amount of heating and cooling needed by installing to 8 indoor units connected to one outdoor unit. units vary by size and style and each creates its own zone of comfort, allowing you to heat or cool individual rooms, hallways and open spaces. Kitchen 74 F Bedroom 7 F Bedroom 68 F Dining Room 70 F REBATES To encourage customers to buy energy efficient products, many local utility companies offer significant rebates for the purchase of a ductless mini-split system. Go to Fujitsu s web site to search for local rebates and consumer loans. We provide a listing of rebates and offerings on qualifying Fujitsu mini-splits by zip code. www.fujitsugeneral.com Electronics 7% 8% Other Fujitsu saves up to 5% on your utility bill Stay Cool. Stay Warm. ENERGY STAR QUALIFIED SYSTEMS A YEAR ROUND SOLUTION Revolutionary Halcyon heat pumps provide both heating and cooling for year round comfort in most climates. A simple push of a button on the remote control allows you to switch from heating to cooling (or vice versa) automatically. If your HVAC equipment is more than years old or not keeping your house comfortable, you should have it looked at by a professional HVAC contractor. If it is not performing efficiently or needs upgrading, consider replacing it with a unit that has earned ENERGY STAR. Installed correctly, these high-efficiency heating and cooling units can save up to 5% on heating and cooling costs. Stay Comfortable. Fujitsu has 30 systems that are ENERGY STAR qualified in 08. See the lineup chart on pages 8-9 for a full listing of all ENERGY STAR qualified systems. OTHER APPLICATIONS The 30RLXEH is specially engineered for spaces such as server rooms which require constant cool temperatures year round, and rooms that hold a large number of people (meeting spaces, classrooms, conference rooms). SEER... EER... HSPF... 8 9

FEATURES COMFORT AND CONVENIENCE APPLICATIONS FLEXIBLE AND QUIET Mini splits offer flexibility because they can be suspended from a ceiling, mounted flush behind a drop ceiling, hung on a wall or floor-standing. Ductless heat pumps allow for a peaceful inside environment by enabling the contractor to install components like compressors and motors outdoors. db(a) Level 40 5 70 35 0 Jet Engine at 0 Power Tools Normal Conversation from 3-5 Whisper Quiet Library Weakest Sound Heard Fujitsu Units ~49 db(a) Set Temp. WHERE CAN MINI-SPLITS BE USED? Convenience stores Fast food chains Fire houses Police stations Bars CONSTANT COMFORT THROUGH INVERTER TECHNOLOGY Inverter technology is like cruise control for your heating or cooling system. Compressors only run as fast as they need to handle the cooling or heating demand. They can handle greater extremes in temperature, are smoother and more stable in operation, and reach the desired temperature more quickly than conventional air conditioners. Inverter Benefits More heat at lower outdoor temperatures Lower RPMs = quieter operation Desired temperature in half the time Up to 30% more efficient Stable temperature Temp. Set Temp. Temp. Conventional System Sunrooms and additions Warehouses Nursing homes Small offices Older homes New construction homes Schools Places of worship Hospitals and medical facilities Restaurants USER FRIENDLY CONTROL Fujitsu is using ergonomics to expand the use of user friendly designs such as easy-to-read large LCD displays, easy-tooperate buttons, and displays with easily recognizable colors and icons. We are producing control systems that provide greater convenience for both individual and centralized control with operability suitable for the application. Optional Wired Remote UTY-RVNUM Standard Wireless Remote for select systems Inverter System Computer rooms Hotels and motels ATM vestibules Server rooms JUST ABOUT ANY PLACE THAT REQUIRES COMFORT!

FEATURES FGLair APP Control your home s climate anytime, anywhere! Access control functions remotely from any smartphone or tablet. FUJITSU HALCYON WIFI SELECTION GUIDE WIFI CONNECTABLE UNITS & MODULES FGLAir IntesisHome RLS3Y & RLS3YH (Built In) WIFI Interface Module IR Wireless Module Wired Module ASU 9//5 RLS3Y UTY-TFNXZ (Add-on) FJ-IR-WIFI-NA (Add-on) FJ-RC-WIFI-NA (Add-on) WALL UNIT SLIM DUCT WHICH APP DOES IT USE? FGLAir IntesisHome FGLAIR APP FEATURES: INTESISHOME APP FEATURES: On/Off Louver/Swing Position On/Off Louver/Swing Position Change Mode Weekly Timer Change Mode Weekly Timer Change Temp Setpoint Economy Setting Change Temp Setpoint Fully Programmable Fan Speed Emailed Error Alerts Fan Speed Alarm Notifications App available on ios and Android. App available on ios and Android. Can also be run through a web browser. CEILING CASSETTE WHERE DOES IT MOUNT? Built into the RLS3Y On the wall next to IDU Up to 0 away from IDU On the wall next to IDU FLOOR UNIT Change temperature COMPATIBLE UNITS: WALL MOUNTS: WALL MOUNTS: WALL MOUNTS: WALL MOUNTS: Set minimum heat Check operation Off ASU9RLS3Y ASU 7 / 9 / RLF¹ ASU 7 / 9 / RLF, ASURLS3Y ASU 7 / 9 / / 5RLF² ASU 7 / 9 / / 5RLF, USER FRIENDLY INTERFACE User friendly screen display facilitates easy operation. Individual AC name display ON/OFF button Room temperature* Temperature setting Operation mode * Only applies to RLS3Y units. Feature not available with Wi-Fi module (UTY-TFNXZ). Second house Check operation On Control up to 4 systems using a single free account. MAIN FUNCTIONS ON / OFF Operation mode Fan speed Louver position Set temperature control Weekly timer Minimum heat ESP function Error display is worldwide trademark of FUJITSU GENERAL LIMITED. ASU5RLS3Y ASU 9 / / 5RLS³ ASU 9 / / 5RLS, ASU 9 / / 5RLS3³ ASU 9 / / 5RLS3, ASU 8 / 4RLF ASU 8 / 4RLF ASU 8 / 4RLF ASU 30 / 36CLX ASU 30 / 36CLX ASU 30 / 36CLX ASU30RLX ASU30RLX ASU30RLX ASU 8 / 4RLB ASU 8 / 4RLB ASU 8 / 4RLB ASU 30 / 36RLXB ASU 30 / 36RLXB ASU 30 / 36RLXB ASU30RLE ASU 9/RL ASU 8CL / 4CL ASU 8CL / 4CL CASSETTES: CASSETTES: CASSETTES: AUU 7 / 9 / / 8RLF AUU 7 / 9 / / 8RLF AUU 7 / 9 / / 8RLF AUU 8 / 4 / 36 / 4RCLX DUCTED: DUCTED: DUCTED: ARU 7 / 9 / / 8 / 4RLF ARU 7 / 9 / / 8 / 4RLF FLOOR MOUNTS: FLOOR MOUNTS: FLOOR MOUNTS: AGU 9 / / 5RLF AGU 9 / / 5RLF UTY-TFNXZ cannot be installed UNIVERSAL / CEILING: UNIVERSAL / CEILING: in conjunction with Wired ABU 8 / 4RULX ABU 8 / 4RULX Remote Controls. ABU36RSLX ABU36RSLX ¹ requires UTY-XCBXZ ² requires UTY-XCBXZ ³ requires UTY-TWBXF 3

FEATURES EXTRA LOW TEMPERATURE HEATING - XLTH NOT ALL HEATING SYSTEMS ARE CREATED EQUAL Without the right technology, a system won t work when its needed most. PROTECTION FROM WINTERS COLDEST TEMPERATURES When the temperature drops you don t want to be left in the cold. It s important to choose a heat pump system rated for the climate you live in. If your system doesn t operate in severe conditions you and your family could be left without any heat at all. Fujitsu s line of mini-split heat pumps come in different sizes, styles, and rated outdoor temperatures. The Extra Low Temperature Heating ( ) Series features outdoor condensing units engineered to operate in temperatures down to. Without the right technology, condensate freezes to the bottom of the unit and reduces its efficiency and heating output. IMPROVED HEATING CAPACITY Heating capacity at low outdoor temperatures was improved by adopting a large heat exchanger and a high capacity compressor. % of Heating Capacity 0 50 Standard Series H Series Models 47 5-5 Ambient Temperature (F ) HIGH PERFORMANCE HEATING Fujitsu XLTH units feature large heat exchangers and high capacity compressors. This gives our XLTH heat pumps the ability to extract heat even at very low outdoor temperatures. For example, at an indoor setpoint of 70 F, all RLS3YH and RLFFH models can deliver 0% or more of their rated heating capacity down to 3 F. All XLTH models also offer superior heating performance down to outdoor temperatures. METAL FAN GUARD BASE PAN HEATER Fujitsu XLTH systems do not have a low temperature lockout, continuing to heat even below as conditions allow. While other models have a plastic fan guard, XLTH models use metal, which is most capable of withstanding the colder elements. Equipped with a heater that prevents condensate from freezing Contoured base design discharges melted water through drain holes. Without a heater, freezing condensate can cause noise, damage to fan blade, condenser, and system performance. Drain Holes Base Heater FEATURE EXPLANATION ENERGY SAVING SEER HSPF portion of your heat pump. 4 5 Economy Saving ESP Minimum Heat COMFORT Auto Changeover Adjust 4-Way Up/Down Restart Dry Fresh Low Noise Powerful Quiet Mode Economy Mode Thermostat setting automatically changes according to the temperature to avoid unnecessary cooling and heating. Energy Saver Keeps room cool enough for comfort by using a relaxed thermostat setting reducing power consumption. Energy Saving Program (ESP) If a space is left without turning the unit off, ESP knows that it is unoccupied and 0 minutes later, temperature is adjusted accordingly until users return to the room. Function is disable in multi-zone installations. ENERGY STAR Qualified Environmental Protection Agency and the U.S. Department of Energy. Minimum Heat Mode Sets room temperature to 50 F, keeping temperatures above freezing and reducing power consumption. Auto Changeover (heating to cooling or vice-versa)* Automatically alternates between heating or cooling if the room temperature or temperature when heating. Auto Fan Mode System starts in high fan speed and automatically adjusts downward as room begins to reach set temperature. Auto Louver: 4 Way Auto Louver: Up/Down can be set to auto swing. Auto Restart Following a power failure, systems will automatically restart in the same operating mode as before, once power has been restored. Dry Mode This mode gives priority to reducing the level of humidity in the room, in conjunction with lowering the temperature. Fresh Air Intake air knockouts. Unit Low Noise+ Limits compressor and fan speed during high speed operation for noise reduction purposes. Powerful Operation compressor speed. Rapid cooling and heating makes the room comfortable quickly. Quiet Mode ( Unit) An extra quiet fan speed to make sure you are not disturbed. + Function is bypassed during defrost and at low speed operation. This feature may limit cooling/ heating capacity during high/low ambient conditions and increase energy consumption as system may need to operate longer due to reduced compressor speed. * Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. CONVENIENCE 4 Hour Sleep Weekly 4 Hour Timer Allows for one on/off cycle during a 4 hour period. Sleep Timer Automatically adjusts the temperature while you sleep to make you more comfortable. Weekly Timer Allows you to set on/off time twice a day and a different on/off time by day. PERFORMANCE Cold 0% @ +5 F Ceiling Ion Pump Down Sensor I/O 3rd Party 0 F Cooling -5 F Cooling Apple Catechin Filter (polyphenol ingredient from apples) electricity and growth is inhibited. 3 - month life expectancy. Cold Prevention coil will warm prior to fan operating, preventing cold air during heating mode. Expanded Heating Performance Delivers 0% of rated heating capacity at +5 F (-5 C). High Ceiling Mode Temperature at the top of a high ceiling room may be warmer than the space occupied; this mode adjusts for this difference. Ion Deodorizing Filter Deodorizes by decomposing absorbed odors using the oxidizing and reducing to restore surface action. Pump Down Operation Collects all refrigerant in system back into the outdoor unit when the unit is to be moved or before servicing the refrigerant circuit. Remote Temperature Sensor Room temperature sensor is located in optional wired remote control only. Third Party Device Control Turns system on or off using a normally closed circuit. Interface with third party devices such as home automation. 0 F Low Ambient Cooling Can operate in cooling mode with outdoor temperatures as low as 0 F. Low Ambient Cooling Can operate in cooling mode with outdoor temperatures down to. INSTALLATION Heater Blue Fin Branch Pump Daisy 4+ ft Piping Slender 6/ Warranty Base Pan Heater Prevents condensate from freezing on the outdoor unit. Blue Fin Heat Exchanger resistance. Branch Duct Capable 38% of the cooling up to feet away. Built-In Condensate Pump Integrated into the indoor unit. Daisy Chain Ability to connect up to identical style indoor units to one wired remote. Long Piping Length Long piping lengths between indoor and outdoor units provides flexibility and increased applications. Slender Fit Cassette body can be moved downward into the room -3/8 to accommodate limited ceiling space. 7/5 Warranty Standard Warranty Fujitsu systems come standard with either a 6 Year Compressor / Year Parts warranty or a 7 Year Compressor / 5 Year Parts warranty. Extended Warranty Additional info on page 7. See full product warranty for details.

SINGLE-ZONE HEAT PUMPS MULTI-ZONE HEAT PUMPS LARGE CASSETTE UNIVERSAL FLOOR / CEILING SLIM DUCT COMPACT CASSETTE WALL MOUNT FLOOR MOUNT Floor Mount Cassette Slim Duct Large Wall (RLF: 8, 4k BTU) Compact Wall (RLF: 7-5k BTU) 4RCLX 36RCLX 4RCLX 8RCLX 36RSLX 4RULX 8RULX 8RLFCD RLFCD 9RLFCD 8RLFCC RLFCC 9RLFCC 5RLFFH 5RLFF RLFFH RLFF 9RLFFH 9RLFF 36RLXB 30RLXB 30RLXEH 4RLXFWH 4RLXFW 4RLB 8RLXFWH 8RLXFW 8RLB 5RLS3YH 5RLS3Y RLS3YH RLS3Y RLFW RL 9RLS3YH 9RLS3Y 9RLFW 9RL.5^.5^ 4.7^.5^.5^ 5.0 4.0 5.0.0 4.0 5.0.0 9.7 0.0. 0..9 4.0 0.3 0.3.7.7 6.0 6.0 5.5.5 8.7 9.5 9.5 8.0 0.0 0.0 9.0 5.3 5.3 9.3 9.3.0.0 33.0 33.0 3.0.0 SEER.3^.3^ 9.3^.3^.3^ 8.5 8.5 8.5 8.5 8.5 8.5 8.5.3.5..5. 3.0.0..3.6.4.6 9.0 9.0.7.0.6.6.4.5.6 3.3 3.4 3.8 4.0.0 9.0 4.0 4..0 9.0 HSPF Economy Mode Economy Energy Saver Saving Energy Saving Pgm (ESP) ESP ENERGY STAR Qualified * Heat Minimum Heat Mode Minimum + + + + SYSTEM FEATURE SUMMARY Auto Auto Changeover Changeover Adjust Auto Fan Mode Auto Louver: 4 Way 4-Way Auto Louver: Up/ Down Up/Down Auto Restart Restart Dry Dry Mode Fresh Air Intake Fresh Unit Low Noise Low Noise Powerful Powerful Operation Mode Quiet Mode ( Unit) Quiet 4 Hour Timer 4 Hour Sleep Timer Sleep Weekly Timer Weekly Apple Catechin Filter Cold Prevention Cold @ +5 F Expanded Htg. Performance 0% Ceiling High Ceiling Mode Ion Deodorizing Filter Ion Pump Down Pump Down Operation Remote Temp. Sensor Sensor Third Party Device Control I/O 3rd Party 0 Low Ambient Clg. 0 F Cooling -5 Low Ambient Clg. -5 F Cooling Base Pan Heater Heater Blue Fin Coil Protection Blue Fin Branch Duct Capable Built-In Condensate Pump Pump Daisy Daisy Chain 4+ ft Piping Long Piping Length (4 +) Slender Fit Slender Warranty: 6 Yr Comp / Yr Parts 6/ Warranty Warranty: up to Yr Comp / Parts Available only with optional wired remote control. Available only with optional wired remote controller and optional Interface Kit. Available only with optional wireless remote control. Available only with optional Interface Kit. Operation monitoring and On/Off control only. Available only with optional Fresh Air Intake Kit. * See bottom of Page 7 for qualifying combinations. ** Operation monitoring and On/Off control only. ^ SEER and HSPF ratings depend on combination of indoor units and outdoor unit selected. + Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. Standard warranty is 5 year Compressor / 7 year Parts. year Compressor/Parts warranty applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 7

MODEL LINEUP SINGLE-ZONE AND MULTI-ZONE SYSTEMS LINEUP Minimum Ambient Cooling Temperature: Minimum Ambient Heating Temperature: SINGLE ZONE DUCTLESS HEAT PUMP SYSTEMS BTU 9,000,000 5,000 8,000 4,000 30,000 36,000 4,000 Wall Mount Highest SEER ASU9RLS3Y / AOU9RLS3 4 F ASURLS3Y / AOURLS3 ASU5RLS3Y / AOU5RLS3 Wall Mount Highest SEER plus ASU9RLS3Y / AOU9RLS3H 4 F 4 F ASURLS3Y / AOURLS3H 4 F ASU5RLS3Y / AOU5RLS3H ASU8RLF / AOU8RLXFWH ASU4RLF / AOU4RLXFWH ASU30RLE / AOU30RLXEH Wall Mount High SEER ASU9RLF / AOU9RLFW 5 F ASURLF / AOURLFW 5 F ASU8RLF / AOU8RLXFW ASU4RLF / AOU4RLXFW Wall Mount Entry Level ASU9RL / AOU9RL 5 F 5 F ASURL / AOURL 5 F 5 F ASU8RLB / AOU8RLB 5 F ASU4RLB / AOU4RLB 5 F 5 F ASU30RLXB / AOU30RLXB 5 F ASU36RLXB / AOU36RLXB Floor Mount Highest SEER AGU9RLF / AOU9RLFF AGURLF / AOURLFF AGU5RLF / AOU5RLFF Floor Mount Highest SEER plus AGU9RLF / AOU9RLFFH AGURLF / AOURLFFH AGU5RLF / AOU5RLFFH Compact Cassette AUU9RLF / AOU9RLFC AUURLF / AOURLFC AUU8RLF / AOU8RLFC Slim Duct Horizontal/Vertical ARU9RLF / AOU9RLFC ARURLF / AOURLFC ARU8RLF / AOU8RLFC Universal Mount Floor/Ceiling 0 F ABU8RULX / AOU8RLX 0 F ABU4RULX / AOU4RLX Ceiling Suspended 0 F ABU36RSLX / AOU36RLX Large Cassette 0 F AUU8RCLX / AOU8RLX 0 F AUU4RCLX / AOU4RLX 0 F AUU36RCLX / AOU36RLX 0 F 0 F AUU4RCLX / AOU4RLX MULTI ZONE DUCTLESS HEAT PUMPS - INDOOR UNITS MULTI ZONE DUCTLESS HEAT PUMPS- OUTDOOR UNITS Compact Wall Mount Large Wall Mount BTU 7,000 9,000,000 5,000 8,000 4,000 ASU7RLF ASU9RLF ASURLF ASU5RLF ASU8RLF ASU4RLF BTU 8,000 ( Units) + 5 F AOU8RLXFZ 4,000 ( - 3 Units) + 5 F AOU4RLXFZ 36,000 (* - 4 Units) 5 F AOU36RLXFZ 45,000 ( - 5 Units) 5 F AOU45RLXFZ 48,000 ( - 8 Units) 3 F 5 F AOU48RLXFZ Slim Duct Compact Cassette Floor Mount ARU7RLF ARU9RLF ARURLF ARU8RLF ARU4RLF AUU7RLF AUU9RLF AUURLF AUU8RLF AGU9RLF AGURLF AGU5RLF + AOU8RLXFZH + AOU4RLXFZH + AOU36RLXFZH * If AOU36RLXFZ is paired with two 8,000 BTU indoor units, you have to purchase optional kit Part #K9FZ88. + The only combinations that qualify for ENERGY STAR are: AOU8RLXFZ with () ASU9RLF AOU8RLXFZH with () ASU9RLF AOU8RLXFZ with () ASU7RLF + () ASURLF AOU4RLXFZ with () ASU7RLF + () ASU9RLF AOU8RLXFZ with () ASU9RLF + () ASURLF AOU4RLXFZH with () ASU7RLF + () ASU9RLF AOU36RLXFZH with (4) ASU9RLF 8 9

FEATURES SINGLE-ZONE MINI-SPLITS SINGLE-ZONE MINI-SPLIT SYSTEMS Making the hottest places cool and the coolest places more comfortable Extensive lineup from 9,000 to 4,000 BTU 3 8 different systems available in 7 indoor unit styles Energy efficient systems with SEER ratings as high as 33.0 and HSPF as high as 4. 5 ENERGY STAR qualified systems 0 Inverter Technology is used in all systems All systems feature environmentally friendly R4A refrigerant Quiet operation with indoor units as low as db and outdoor units as low as 47dB 9,, 5,000 BTUh WALL MOUNT HEAT PUMPS Economy ESP Minimum Heat Changeover 0% @ Sleep Weekly Cold +5 F Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wired Remote Control and optional interface kit. 3 Available only with optional interface kit. Operation monitoring and On/Off control only. 4 XLTH models only ENERGY SAVING PROGRAM These Halcyon systems know how to save you money even when you forget. If you leave the room without turning the unit off, ESP knows that you left and 0 minutes later, set temperature is increased by 4 F when cooling and reduced by 8 F when heating. When you come back to the room, it returns to previous operating mode.this prevents wasteful operation to save energy without you having to think about it. This feature can be deactivated if chosen. HIGH PERFORMANCE HEATING The RLS3Y model can operate down to. The RLS3YH can operate down to. See the full story on page 4. Auto Wi-Fi Enabled Adjust 4-Way Restart Ion Sensor I/O 3rd Party 3 BUILT-IN WI-FI Remotely operate your heating and cooling system using a smartphone as a remote control. Details on page. Dry Low Noise Powerful Quiet Mode 4 Hour Heater OPTIONAL ACCESSORIES Wired Remote Control: UTY-RVNUM Wired Remote Control: UTY-RNNUM Simple Remote Control: UTY-RSNUM Interface Kit: UTY-TWBXF Dry Contact Wire Kit: UTY-XWZXZ5 4 Daisy SYSTEMS 9RLS3Y, RLS3Y, 5RLS3Y HIGH HEAT SYSTEMS 9RLS3YH, RLS3YH, 5RLS3YH UP TO 33.0 SEER 9RLS3Y RLS3Y 5RLS3Y 9RLS3YH RLS3YH 5RLS3YH Performance Nominal Cooling BTUh 9,000,000 4,500 9,000,000 4,500 Min.-Max. Cooling BTUh 3,0~,000 3,0~3,600 3,0~8,400 3,0~,000 3,0~3,600 3,0~8,400 Nominal Heating BTUh,000,000 8,000,000,000 8,000 Min.-Max. Heating BTUh 3,0~,000 3,0~,0 3,0~3,900 3,0~,000 3,0~,0 3,0~3,900 SEER 33.0 9.3 5.3 33.0 9.3 5.3 HSPF 4. 4.0 3.4 4.0 3.8 3.3 EER 8.0 5. 3.9 8.0 5. 3.9 Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) -5~75 (-~4) -5~75 (-~4) -5~75 (-~4) -5~75 (-6~4) -5~75 (-6~4) -5~75 (-6~4) Moisture Removal Pt./h (l/h).6 (.).7 (.3) 4.0 (.9).6 (.).7 (.3) 4.0 (.9) 7% 38% 40% 7% 38% 40% 56% 5% 4% 56% 5% 4% -- -- -- 3% 98% 9% Fan Air Circulation: Hi CFM (m3/h) 489 (830) 489 (830) 547 (930) 489 (830) 489 (830) 547 (930) Medium CFM (m3/h) 400 (680) 400 (680) 459 (780) 400 (680) 400 (680) 459 (780) Low CFM (m3/h) 34 (580) 34 (580) 37 (630) 34 (580) 34 (580) 37 (630) Quiet CFM (m3/h) 4 (380) 4 (380) Clg 59 (440) Clg 59 (440) 4 (380) 4 (380) Htg 94 (500) Htg 94 (500) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto Sound Level (Clg/Htg): Hi db(a) 4/4 4/4 45/45 4/4 4/4 45/45 Medium db(a) 37/35 37/35 40/39 37/35 37/35 40/39 Low db(a) 3/3 3/3 34/33 3/3 3/3 34/33 Quiet db(a) 3/3 3/3 6/7 3/3 3/3 6/7 Level Clg/Htg db(a) 4/47 43/47 49/50 4/47 43/47 49/50 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 5 5 0 5 5 0 Current Rated/Max: Cooling Amps.5/9.4 3.8/9.4 4.8/9.9.5/9.4 3.8/9.4 4.8/9.9 Current Rated/Max: Heating Amps 3.3/.0 4.7/.9 5./3.9 3.3/.0 4.7/.9 5./3.9 Power Use Rated/Max: Cooling kw 0.50/0.85 0.79/0.99.04/.56 0.50/0.85 0.79/0.99.04/.56 Power Use Rated/Max: Heating kw 0.66/.93.0/.94.5/.9 0.66/.93.0/.94.5/.9 Size & Weight Net Weight lbs. (kg) 3 (4) 84 (38) 3 (4) 84 (38) 3 (4) 86 (39) 3 (4) 86 (39) 3 (4) 86 (39) 3 (4) 88 (40) Inch -5/8 4-7/ -5/8 4-7/ -5/8 4-7/ -5/8 4-7/ -5/8 4-7/ -5/8 4-7/ mm 95 60 95 60 95 60 95 60 95 60 95 60 Inch 37 3-/8 37 3-/8 37 3-/8 37 3-/8 37 3-/8 37 3-/8 mm 940 790 940 790 940 790 940 790 940 790 940 790 Depth Inch -5/8-7/ -5/8-7/ -5/8-7/ -5/8-7/ -5/8-7/ -5/8-7/ mm 70 90 70 90 70 90 70 90 70 90 70 90 Refrigerant R4A R4A R4A R4A R4A R4A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Automatic Automatic Automatic Vertical Automatic Automatic Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Washable Washable Minimum Lineset Length Ft (m) Maximum Lineset Length Ft (m) 66 (0) 66 (0) 66 (0) 66 (0) 66 (0) 66 (0) Max. Vertical Diff. Ft (m) 49 (5) 49 (5) 49 (5) 49 (5) 49 (5) 49 (5) Lineset Size Inch Suc.3/8 Dis./4 Suc.3/8 Dis./4 Suc./ Dis./4 Suc.3/8 Dis./4 Suc.3/8 Dis./4 Suc./ Dis./4 * Based on model # capacity class (e.g. 9RLS3Y based on 9,000 BTUh) @ 70 F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data. ASU9RLS3Y AOU9RLS3 ASURLS3Y AOURLS3 ASU5RLS3Y AOU5RLS3 ASU9RLS3Y AOU9RLS3H ASURLS3Y AOURLS3H ASU5RLS3Y AOU5RLS3H Note: Figures are based on 30 Volts.

MULTI-ZONE SINGLE-ZONE MINI-SPLITS 9 AND,000 BTUh WALL MOUNT HEAT PUMPS HFI SYSTEMS 9RLFW, RLFW UP TO 3 SEER 9RLFW RLFW Economy Minimum Heat Changeover BUILT IN FILTRATION LONG-LIFE ION DEODORIZATION FILTER Ion The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultrafine particle ceramic. The filter can be used for approximately 3 years if it is washed with water when dirty to restore its surface action. APPLE-CATECHIN FILTER Dust, mold spores and micro-organisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. Filter lasts 3- months. Auto Cold Ion Sensor 3 Adjust Up/Down Restart I/O 3rd Party 4 Daisy 3 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wired remote control. 3 Available only with optional wired remote control and optional interface kit. 4 Available only with optional interface kit. Operation monitoring and On/Off control only. Ion Deodorization Filter Apple-catechin Filter Air Filter Dry Powerful Quiet Mode 4 Hour Sleep Weekly OPTIONAL ACCESSORIES W ired Remote Control: UTY-RVNUM* Wired Remote Control: UTY-RNNUM* Simple Remote Control: UTY-RSNUM* Dry Contact Wire Kit: UTY-XWZXZ5 Interface Kit: UTY-XCBXZ * Wall mounted ASU9, RLF require accessory interface kit #UTY-XCBXZ in order to connect these devices to them. Performance Nominal Cooling BTUh 9,000,000 Min.-Max. Cooling BTUh,700~,900 3,0~3,300 Nominal Heating BTUh,000,000 Min.-Max. Heating BTUh,700~5,000 3,0~9,0 SEER 3.0.0 HSPF.0.0 EER 3.8.5 Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) 5~75 (-5~4) 5~75 (-5~4) Moisture Removal Pt./h (l/h).75 (.3) 3.80 (.8) Fan Air Circulation: Hi CFM (m3/h) 44 (750) 44 (750) Medium CFM (m3/h) 376 (640) 376 (640) Low CFM (m3/h) 8 (480) Clg 8 (480) Clg 306 (50) Htg 306 (50) Htg Quiet CFM (m3/h) 8 Clg 8 Clg 94 (330) Htg 94 (330) Htg Fan Speed Stage 4+Auto 4+Auto Sound Sound Level (Clg/Htg): Hi db(a) 43/43 43/43 Medium db(a) 40/38 40/38 Low db(a) 3/33 3/33 Quiet db(a) / / Sound Level Clg/Htg db(a) 48/48 49/49 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ Circuit Breaker Amps 0 0 Current Rated/Max: Cooling Amps 3./6.0 4.4/6.5 Current Rated: Heating Amps 4./7.5 5.9/9.0 Power Use Rated/Max: Cooling kw 0.65/.7 0.96/.40 Power Use Rated: Heating kw 0.89/.60.8/.99 Size & Weight Net Weight lbs. (kg) 8 (8) 60 (7) 8 (8) 80 (36) Inch -/ -/4 -/ -/4 mm 68 540 68 540 Inch 33-/ 6 33-/ 3 mm 840 660 840 790 Depth Inch 8-7/ 8-7/ mm 03 90 03 90 Refrigerant R4A R4A Additional Data Air Direction: Horizontal Manual Manual Vertical Automatic Automatic Air Filter Washable Washable Minimum Lineset Length Ft (m) Maximum Lineset Length Ft (m) 66 (0.) 66 (0.) Max. Vertical Diff. Ft (m) 49 (5) 49 (5) Lineset Size Inch Suc. 3/8 Dis. /4 Suc. 3/8 Dis. /4 ASU9RLF AOU9RLFW ASURLF AOURLFW Note: Figures are based on 30 Volts. 3

SINGLE-ZONE MINI-SPLITS 8 AND 4,000 BTUh WALL MOUNT HEAT PUMPS HFI SYSTEMS 8RLXFW, 4RLXFW HIGH HEAT SYSTEMS 8RLXFWH, 4RLXFWH 8RLXFW 4RLXFW 8RLXFWH 4RLXFWH UP TO 0 SEER Economy Minimum Heat Changeover Cold 0% @ +5 F HIGH PERFORMANCE HEATING CAPACITY Stay comfortable at low ambient temperatures! The RLXFW systems can deliver 0% or more of rated heating capacity at 5 F (-5 C) and operates down to (- C). The RLXFWH model can operate down to. See the full story on page 4. OPTIONAL ACCESSORIES Auto Wired Remote Control: UTY-RVNUM Wired Remote Control: UTY-RNNUM Simple Remote Control: UTY-RSNUM Dry Contact Wire Kit: UTY-XWZX Ion Sensor Adjust 4-Way Restart 4 I/O 3rd Party Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. RLXFW systems only. 3 RLXFW systems require optional wired remote control. 5-5 F Cooling Dry Quiet Mode 4 Hour Heater 6 Blue Fin Daisy 4 4+ ft Sleep Weekly Piping 4 Available only with optional wired remote control. 5 Available only with optional Interface kit. Operation monitoring and On/Off control only. 6 RLXWFH models only. Maximum heating capacity 80% 0% 40% 0% 0% 8K 4K 80% -5 5 4 3 3 4 temperature ( F) Based on 70 indoor setpoint RLXFWH Maximum heating capacity 80% 0% 40% 0% 0% 80% -5º -5º 8KH 5º 47 4º Based on 70 indoor setpoint 50 3º 4KH 3º 4º temperature ( F) 3 RLXFW 47º 50º Performance Nominal Cooling BTUh 8,000,000 8,000,000 Min.-Max. Cooling BTUh 7,000~3,000 9,900~7,300 7,000~3,000 9,900~7,300 Nominal Heating BTUh,600 5,00,600 5,00 Min.-Max. Heating BTUh 7,000~9,000 7,500~36,00 7,000~9,000 7,500~36,00 SEER 0.0 9.5 0.0 9.5 HSPF.5.6.4.5 EER 3.3.5 3.3.5 Cooling Operating Range F ( C) -5~5 (-0~46) -5~5 (-0~46) -5~5 (-0~46) -5~5 (-0~46) Heating Operating Range F ( C) -5~75 (-0~4) -5~75 (-0~4) -5~75 (-6~4) -5~75 (-6~4) Moisture Removal Pt./h (l/h) 5.9 (.8) 6.3 (3.0) 5.9 (.8) 6.3 (3.0) 0% 5% 0% 5% 9% 94% 9% 94% - - 0% 8% Fan Air Circulation: Hi CFM (m3/h) 54 (90) Clg 659 (,0) Clg 659 (,0) 54 (90) Htg 677 (,50) Htg 677 (,50) Medium CFM (m3/h) 435 (740) 530 (900) 435 (740) 530 (900) Low CFM (m3/h) 365 (60) 435 (740) 365 (60) 435 (740) Quiet CFM (m3/h) Clg 306 (50) Clg 306 (50) 365 (60) Htg 38 (540) Htg 38 (540) 365 (60) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto Sound Level (Clg/Htg): Hi db(a) 43/44 49/49 43/44 49/49 Medium db(a) 37/37 4/4 37/37 4/4 Low db(a) 33/33 37/37 33/33 37/37 Quiet db(a) 8/8 33/33 8/8 33/33 Level Clg/Htg db(a) 47/50 54/55 47/50 54/55 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 0 30 0 0 Current Rated/Max: Cooling Amps 6./3.5 7.9/5.0 6./3.5 7.9/5 Current Rated/Max: Heating Amps 7.8/4.5 8.6/5.5 7.8/4.5 8.6/5.5 Power Use Rated/Max: Cooling kw.35/3.0.76/3.4.35/3.0.76/3.4 Power Use Rated/Max: Heating kw.80/3.3.38/3.53.75/3.3.94/3.53 Size & Weight Net Weight lbs. (kg) 3 (4) 34 (6) 3 (4) 34 (6) 3 (4) 35 (6) 3 (4) 35 (6) Inch -5/8 3-3/4-5/8 3-3/4-5/8 3-3/4-5/8 3-3/4 mm 30 830 30 830 30 830 30 830 Inch 39-/4 35-3/8 39-/4 35-3/8 39-/4 35-3/8 39-/4 35-3/8 mm 998 900 998 900 998 900 998 900 Depth Inch 9 3 9 3 9 3 9 3 mm 8 330 8 330 8 330 8 330 Refrigerant R4A R4A R4A R4A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Automatic Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Minimum Lineset Length Ft (m) (5) (5) (5) (5) Maximum Lineset Length Ft (m) 4 (50) (pre-charge: 66 ) 4 (50) (pre-charge: 66 ) 4 (50) (pre-charge: 65 ) 4 (50) (pre-charge: 65 ) Max. Vertical Diff. Ft (m) 98 (30) 98 (30) 30 (98) 30 (98) Lineset Size Inch Suc. 5/8 Dis. 3/8 Suc. 5/8 Dis. 3/8 Suc.5/8 Dis.3/8 Suc.5/8 Dis.3/8 * Based on model # capacity class (e.g. 9RLS3Y based on 9,000 BTUh) @ 70 F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data. 4 5 ASU8RLF AOU8RLXFW ASU4RLF AOU4RLXFW ASU8RLF AOU8RLXFWH ASU4RLF AOU4RLXFWH Note: Figures are based on 30 Volts.

SINGLE-ZONE MINI-SPLITS 30,000 BTUh WALL MOUNT HEAT PUMP Weekly Economy ESP Minimum Heat Changeover Cold SERVER ROOM MODE Server rooms can generate a tremendous amount of heat, and require cooling 4 hours a day. The strain of such a heat load is best handled with a redundant cooling system. Pairing two 30RLXEH systems together in Server Room Mode offers a unique solution for keeping network servers cool. Two 30RLXEH systems can be set up to work together in Lead Lag^ operation: Alternative Operation units alternate operation, so neither unit is running at the same time. Backup Operation if an error occurs on one unit, the second unit will turn on. Supporting Operation if the setpoint cannot be reached with one unit alone, the second unit will come on to satisfy the demand for cooling. ^ Wired remotes cannot be used when using this feature. This includes UTY-RNRUZ, UTY-RVNUM, UTY-RNNUM, UTY-RSNUM. LOCK OUT FUNCTION 0% @ +5 F This feature is set by the contractor on behalf of the Commercial Property Owner to prevent either Cooling or Heating operation from occurring. This is not a function that can be set by a tenant, user, or home owner. Auto HIGH PERFORMANCE HEATING CAPACITY The RLXEH model can operate down to. See the full story on page 4. Ion Adjust 4-Way Restart Pump Down Sensor I/O 3rd Party Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wired remote control. 3 Available only with optional Interface kit. EXTENDED LINESET Long piping lengths between indoor and outdoor units provides flexibility and increased applications. MAX PIPE LENGTH System 30RLXEH 46 ft. (75m) Dry Low Noise Powerful Quiet Mode Sleep 3-5 F Cooling Heater Blue Fin Daisy 4+ ft Piping ADDITIONAL APPLICATIONS THAT MAY REQUIRE LOW AMBIENT COOLING: Conference/Meeting/Training Rooms Social Gathering spots Places of Worship OPTIONAL ACCESSORIES Max Height Diff. 98 ft. (30m) Wired Touch Panel Remote Controller: UTY-RNRUZ^ Wired Remote Control: UTY-RVNUM^ Wired Remote Control: UTY-RNNUM^ Simple Remote Control: UTY-RSNUM^ Dry Contact Wire Kit: UTY-XWZX Interface Kit: UTY-XCSXZ Interface Kit Box: UTZ-GXXB Unit Input/Output Connector: UTY-XWZXZ3 The 30RLXEH is specially engineered for spaces such as server rooms which require constant cool temperatures year round, and rooms that hold a large number of people (meeting spaces, classrooms, conference rooms). UP TO 8.7 SEER HIGH-HEAT SYSTEM 30RLXEH 30RLXEH Performance Nominal Cooling BTUh 30,000 Min.-Max. Cooling BTUh 9,900~3,400 Nominal Heating BTUh 3,000 Min.-Max. Heating BTUh 8,000~37,500 SEER 8.7 HSPF.7 EER.5 Cooling Operating Range F ( C) -5~5 (-0~46) Heating Operating Range F ( C) -5~75 (-6~4) Moisture Removal Pt./h (l/h) 9.7 (4.6) 7% 9% 76% Fan Air Circulation: Hi CFM (m3/h) 8 (,380) Medium CFM (m3/h) 665 (,30) Low CFM (m3/h) 536 (9) Quiet CFM (m3/h) 48 (7) Fan Speed Stage 4+Auto Sound Sound Level (Clg/Htg): Hi db(a) 50/49 Medium db(a) 45/44 Low db(a) 38/38 Quiet db(a) 3/3 Sound Level Clg/Htg db(a) 53/54 Electrical Voltage/Frequency/Phase 08-30/60/ Circuit Breaker Amps 30 Current Rated: Cooling Amps.6 Current Rated: Heating Amps.0 Power Use Rated/Max: Cooling kw.40/3.83 Power Use Rated/Max: Heating kw.74/4.8 Size & Weight Net Weight lbs. (kg) 40 (8) 05 (93) Inch 3-3/8 50-3/ mm 340,90 Inch 45-/4 35-3/8 mm,50 900 Depth Inch 3 mm 80 330 Refrigerant R4A Additional Data Air Direction: Horizontal Automatic Vertical Automatic Air Filter Washable Minimum Lineset Length Ft (m) (5) Maximum Lineset Length Ft (m) 46 (75) (pre-charge: 65 ) Max. Vertical Diff. Ft (m) 30 (98) Lineset Size Inch Suc.5/8 Dis.3/8 * Based on model # capacity class (e.g. 9RLS3Y based on 9,000 BTUh) @ 70 F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data. Note: Figures are based on 30 Volts. ASU30RLE AOU30RLXEH 6 7

SINGLE-ZONE MINI-SPLITS 9 AND,000 BTUh, 5V, WALL MOUNT HEAT PUMPS SYSTEMS 9RL, RL FUNCTION Auto Economy Changeover Stylish, slim and elegant, these popular wall mounted units are designed for single rooms. units have a clean, aesthetic design and are small but mighty and shorter in length than competing units, helping them blend into any room. EASY MAINTENANCE Adjust Up/Down Restart Front panel is easily removed for cleaning. Dry Powerful Quiet Mode Sleep Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details. APPLICATIONS Cold This category of equipment is ideal for smaller spaces where spot cooling or heating is required. Residential applications including sunrooms and additions are made easier with these 5 volt heat pumps. Do you have a warm or cool spot in your home? Fujitsu mini-splits can provide extra cooling or heating capacity for those hard to cool areas. Commercially, their small size makes them ideal for small offices, providing individual temperature control..0 SEER 9RL RL Performance Nominal Cooling BTUh 9,000,000 Min.-Max. Cooling BTUh,700~,700 3,0~,500 Nominal Heating BTUh,000 4,000 Min.-Max. Heating BTUh,700~,000 3,0~,000 SEER.0.0 HSPF 9.0 9.0 EER.8.0 Cooling Operating Range F ( C) 5~5 (-~46) 5~5 (-~46) Heating Operating Range F ( C) 5~75 (-~4) 5~75 (-~4) Moisture Removal Pt./h (l/h).7 (.3) 3.8 (.8) Fan Air Circulation: Hi CFM (m3/h) 436 (740) 436 (740) Medium CFM (m3/h) 353 (600) 353 (600) Low CFM (m3/h) 65 (450) 65 (450) Quiet CFM (m3/h) 9 (35) 9 (35) Fan Speed Stage 4 + Auto 4 + Auto Sound Sound Level (Clg/Htg): Hi db(a) 43/43 43/43 Medium db(a) 38/38 38/38 Low db(a) 33/33 33/33 Quiet db(a) 3/3 3/3 Sound Level Clg/Htg db(a) 47/48 5/5 Electrical Voltage/Frequency/Phase 5/60/ 5/60/ Circuit Breaker Amps 5 0 Current Rated: Cooling Amps 7.5.9 Current Rated: Heating Amps 7.0.0 Power Use Rated: Cooling kw 0.83.0 Power Use Rated: Heating kw 0.77. Size & Weight Net Weight lbs. (kg) (7) 64 (9) (7) 69 (3) Inch -5/ -/4-5/ -/4 mm 6 540 6 540 Inch 3-9/3 6 3-9/3 6 mm 80 660 80 660 Depth Inch 8-/8 -/3 8-/8 -/3 mm 06 90 06 90 Refrigerant R4A R4A Additional Data Air Direction: Horizontal Manual Manual Vertical Automatic Automatic Air Filter Washable Washable Minimum Lineset Length Ft (m) Maximum Lineset Length Ft (m) 66 (0) 66 (0) Max. Vertical Diff. Ft (m) 49 (5) 49 (5) Lineset Diameter Inch Suc. 3/8 Dis. /4 Suc. 3/8 Dis. /4 ASU9RL AOU9RL ASURL AOURL Note: Figures are based on 5 Volts. 8 9

SINGLE-ZONE MINI-SPLITS 8, 4, 30, 36,000 BTUh WALL MOUNT HEAT PUMPS SYSTEMS 8RLB, 4RLB, 30RLXB, 36RLXB Ion Sensor FUNCTION Auto Economy Minimum Heat Changeover I/O 3rd Party Stylish, slim and elegant, these wall mounted ductless heat pumps are designed for single rooms. Ideal for spaces requiring additional capacity but are limited on space. With more efficient zone control, ductless mini-splits are perfect for renovations, restorations, conversions, and add-ons. OPTIONAL ACCESSORIES Wired Remote Control: UTY-RVNUM Wired Remote Control: UTY-RNNUM Simple Remote Control: UTY-RSNUM Dry Contact Wire Kit: UTY-XWZX 3 Blue Fin 4 Adjust 4-Way Restart Daisy 4+ ft 4 Piping AOU8RLB AOU4RLB Dry Quiet Mode Sleep Weekly Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wired remote control. 3 Available only with optional Interface kit. 4 RLXB models only. LOCK OUT FUNCTION AOU30RLXB AOU36RLXB This feature is set by the contractor on behalf of the Commercial Property Owner to prevent either Cooling or Heating operation from occurring. This is not a function that can be set by a tenant, user, or home owner. Cold UP TO 9.0 SEER 8RLB 4RLB 30RLXB 36RLXB Performance Nominal Cooling BTUh 8,000 4,000 30,000 33,000 Min.-Max. Cooling BTUh 3,0~9,000 3,0~5,000 9,900~3,400 9,900~34,0 Nominal Heating BTUh 8,000 4,000 30,000 34,000 Min.-Max. Heating BTUh 7,000~0,000 7,500~7,000 8,000~33,000,00~35,000 SEER 9.0 8.0.5 5.5 HSPF.6.6 9.0 9.0 EER.5.0 9.5 8.5 Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) 5~75 (-5~4) 5~75 (-5~4) 5~75 (-5~4) 5~75 (-5~4) Moisture Removal Pt./h (l/h) 4.0 (.9) 6.3 (3.0) 9.7 (4.6). (4.8) Fan 659 (,0) Clg 659 (,0) Clg Air Circulation: Hi CFM (m3/h) 54 (90) 647 (,0) Htg 677 (,50) Htg 695 (,80) Medium CFM (m3/h) 439 (740) 530 (900) 530 (900) 530 (900) Low CFM (m3/h) 365 (60) 436 (740) 436 (740) 436 (740) Quiet CFM (m3/h) 306 (50) 365 (60) 365 (60) 365 (60) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto Sound Sound Level (Clg/Htg): Hi db(a) 4/43 47/47 47/49 50/50 Medium db(a) 35/36 4/4 4/4 4/4 Low db(a) 3/33 35/36 37/37 37/37 Quiet db(a) 6/8 3/33 3/33 3/33 Sound Level Clg/Htg db(a) 5/50 54/55 5/55 5/55 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 5 0 30 30 Current Rated/Max: Cooling Amps 6.4/8.3.5/.8 3.8/.8 7.0/8.0 Current Rated/Max: Heating Amps 5.8/.8 8.5/3.8.3/8.8 4.8/8.8 Power Use Rated: Cooling kw.44/.89.40/.69 3./3.83 3.88/4. Power Use Rated: Heating kw.9/.69.93/3.4.80/4.8 3.39/4.8 Size & Weight Net Weight lbs. (kg) 3 (4) 86 (39) 3 (4) 86 (39) 3 (4) 34 (6) 3 (4) 34 (6) Inch -5/8 4-7/ -5/8 4-7/ -5/8 3-/ -5/8 3-/ mm 30 60 30 60 30 830 30 830 Inch 39-5/ 3-/8 39-5/ 3-/8 39-5/ 35-7/ 39-5/ 35-7/ mm 998 790 998 790 998 900 998 900 Depth Inch 9-7/ 9-7/ 9 3 9 3 mm 8 90 8 90 8 330 8 330 Refrigerant R4A R4A R4A R4A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Automatic Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Minimum Piping Length Ft (m) (5) (5) Maximum Piping Length Ft (m) 66 (0) 66 (0) 5 (50) (pre-charge: 66 ) 5 (50) (pre-charge: 66 ) Maximum Vertical Differential Ft (m) 49 (5) 49 (5) 98 (30) 98 (30) Lineset Size Inch Suc./ Dis./4 Suc./ Dis./4 Suc.5/8 Dis.3/8 Suc.5/8 Dis.3/8 ASU8RLB AOU8RLB ASU4RLB AOU4RLB ASU30RLXB AOU30RLXB ASU36RLXB AOU36RLXB Note: Figures are based on 30 Volts. 30 3

SINGLE-ZONE MINI-SPLITS 9,, 5,000 BTUh FLOOR MOUNT HEAT PUMPS HFI SYSTEMS 9RLFF, RLFF, 5RLFF HIGH HEAT SYSTEMS 9RLFFH, RLFFH, 5RLFFH UP TO 6 SEER 9RLFF RLFF 5RFF 9RLFFH RLFFH 5RLFFH At less than 4 high and 30 wide, floor mount models fit easily under a standard window and can replace a radiator twice its size while producing more capacity. 3-5/8 Beneath standard window 9-/8 Economy Minimum Heat Changeover Cold 0% @ +5 F TWO FANS AND WIDE AIRFLOW Having both upper and lower airflow quickly warms or cools the entire room. Floor mount can be set in Upward Airflow Only when occupants wish not to have feet warmed or cooled. FLEXIBLE AND EASY INSTALLATION 7-7/8 7-9/ Auto Ion Sensor IDEAL RADIATOR REPLACEMENT Min. 7-9/ Adjust Up/Down Restart Heater Standard concave portion Min. 37 3 Daisy Dry Powerful Quiet Mode 4 Hour Sleep Weekly Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available with optional wired remote control. 3 RLFFH models only. BASE PAN HEATER (RLFFH MODELS) RLFF models can operate down to. RLFFH models can operate down to. See the full story on page 4. OPTIONAL ACCESSORIES Wired Remote Control: UTY-RVNUM Wired Remote Co ntroller: UTY-RNNUM Simple Remote Control: UTY-RSNUM Dry Contact Wire Kit: UTY-XWZXZ5 Cooling Fig. Fig. Heating Fig. Fig. Wall Max. 5-7/8 Window. Upon startup, both top and bottom louvers open.. As the room temperature nears the setpoint, only the top louver stays open to help prevent cold air from falling.. Upon startup, both top and bottom louvers open.. Closer to setpoint, only the top louver stays open to help prevent cold drafts from windows. Min. 3- /4 Half concealed* Min. 8-3/4 Max. 3-/8 * Field supplied insulation required Performance Nominal Cooling BTUh 9,000,000 4,00 9,000,000 4,00 Min.-Max. Cooling BTUh 3,0~3,000 3,0~4,300 3,0~7,700 3,0~3,000 3,0~4,300 3,0~7,700 Nominal Heating BTUh,000,000 8,000,000,000 8,000 Min.-Max. Heating BTUh 3,0~8,800 3,0~,0 3,0~3,900 3,0~8,800 3,0~9,500 3,0~0,800 SEER 6.0.7 0.3 6.0.7 0.3 HSPF.6.6..4.3.0 EER.0 3..5.0 3..5 Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) -5~75 (-~4) -5~75 (-~4) -5~75 (-~4) -5~75 (-6~4) -5~75 (-6~4) -5~75 (-6~4) Moisture Removal Pt./h (l/h).75 (.3) 3.8 (.8) 4.44 (.).75 (.3) 3.8 (.8) 4.44 (.) 49% 5% 8% 49% 5% 8% 30% % 7% 30% % 7% -- -- -- 5% 0% 96% Fan Air Circulation: Hi CFM (m3/h) 335 (570) 335 (570) 383 (650) 335 (570) 335 (570) 383 (650) Medium CFM (m3/h) 7 (460) 7 (460) 306 (50) 7 (460) 7 (460) 306 (50) Low CFM (m3/h) (360) (360) 35 (400) (360) (360) 35 (400) Quiet CFM (m3/h) 59 (70) 59 (70) 59 (70) 59 (70) 59 (70) 59 (70) Fan Speed Stage 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto 4+Auto Sound Level (Clg/Htg): Hi db(a) 40/40 40/40 44/43 40/40 40/40 44/43 Medium db(a) 35/35 35/35 38/37 35/35 35/35 38/37 Low db(a) 9/9 9/9 3/9 9/9 9/9 3/9 Quiet db(a) 3/3 3/3 3/3 3/3 3/3 3/3 Level Clg/Htg db(a) 50/50 5/5 54/54 50/50 5/5 54/54 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 5 5 0 5 5 0 Current Rated: Cooling Amps.9 4. 5..9 4. 5. Current Rated: Heating Amps 4. 6.7 7.0 4. 6.7 7.0 Power Use Rated: Cooling kw.56.97.3.56.97.3 Power Use Rated: Heating kw.88.44.58.88.44.58 Size & Weight Net Weight lbs. (kg) 3 (4) 84 (38) 3 (4) 84 (38) 3 (4) 86 (39) 3 (4) 86 (39) 3 (4) 86 (39) 3 (4) 88 (40) Inch 3-5/8 4-7/ 3-5/8 4-7/ 3-5/8 4-7/ 3-5/8 4-7/ 3-5/8 4-7/ 3-5/8 4-7/ mm 600 60 600 60 600 60 600 60 600 60 600 60 Inch 9-/8 3-/8 9-/8 3-/8 9-/8 3-/8 9-/8 3-/8 9-/8 3-/8 9-/8 3-/8 mm 740 790 740 790 740 790 740 790 740 790 740 790 Depth Inch 7-7/8-7/ 7-7/8-7/ 7-7/8-7/ 7-7/8-7/ 7-7/8-7/ 7-7/8-7/ mm 00 90 00 90 00 90 00 90 00 90 00 90 Refrigerant R4A R4A R4A R4A R4A R4A Additional Data Air Direction: Horizontal Manual Manual Manual Manual Manual Manual Vertical Auto Auto Auto Auto Auto Auto Air Filter Washable Washable Washable Washable Washable Washable Minimum Lineset Length Ft (m) Maximum Lineset Length Ft (m) 66 (0) 66 (0) 66 (0) 66 (0) 66 (0) 66 (0) Max. Vertical Differential Ft (m) 49 (5) 49 (5) 49 (5) 49 (5) 49 (5) 49 (5) Lineset Size Inch Suc. 3/8 Dis. /4 Suc. 3/8 Dis. /4 Suc. / Dis. /4 Suc. 3/8 Dis. /4 Suc. 3/8 Dis. /4 Suc. / Dis. /4 * Based on model # capacity class (e.g. 9RLS3Y based on 9,000 BTUh) @ 70 F indoor setpoint. Refer to the Design & Technical Manual for more heating capacity data. AGU9RLF AOU9RLFF AGURLF AOURLFF AGU5RLF AOU5RLFF AGU9RLF AOU9RLFFH AGURLF AOURLFFH AGU5RLF AOU5RLFFH Note: Figures are based on 30 Volts. 3 33

SINGLE-ZONE MINI-SPLITS 9,, 8,000 BTUh COMPACT CASSETTE HEAT PUMPS HFI SYSTEMS 9RLFCC, RLFCC, 8RLFCC 9RLFCC RLFCC 8RLFCC Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wireless remote control. 3 Requires Fujitsu s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at. W.C. or 90 CFM at.4 W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4 to the height of the indoor unit. 4 Available only with optional Interface kit. Operation monitoring and On/Off control only. FUNCTION Compact cassettes provide comfort cooling or heating for small room applications. Features include high efficiency up to 4.0 SEER, heating at low temperatures down to, compact design, quiet operation, a standard wired remote control, and the ability to bring in fresh air through the optional Fresh Air Kit. EASY INSTALLATION Fits into a standard ceiling tile*. -STAGE TURBO FAN 34 Economy Ceiling Sensor Minimum Heat I/O 3rd Party 4.5.5 *Dimensions of outer grille are 7-9/ x 7-9/ and may overlap adjacent tiles. Air distribution is evenly spread across the heat exchanger by the stage turbo fan which produces two separate airflow streams. Heat exchange efficiency: Increased 0% Compact Cassette Grille UTG-CCGF shown is sold separately and must be ordered with each compact cassette. Auto Changeover Pump Adjust Up/Down Restart Daisy -stage -stage Dry Fresh 3 QUIET OPERATION Quiet Mode Weekly Cold 0% @ +5 F Optimization of wing form (laminar wing design) and number of wings (7 blades) enables as low as 7 db. OPTIONAL ACCESSORIES Wired Remote Control: UTY-RVNUM Wireless remote UTY-LNHU F resh Air Kit 3 UTZ-VXAA Mixes room air which then passes through the heat exchanger. UP TO 4.0 SEER Performance Nominal Cooling BTUh 9,000,000 8,000 Min.-Max. Cooling BTUh 3,0~,000 3,0~3,600 3,0~0,0 Nominal Heating BTUh,000,000,600 Min.-Max. Heating BTUh 3,0~8,000 3,0~9,400 3,0~5,600 SEER 4.0.9 0. HSPF 3.0..5 EER 4.5.8. Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) -5~75 (-~4) -5~75 (-~4) -5~75 (-~4) Moisture Removal Pt./h (l/h).3 (.06).5 (.) 4.6 (.) Fan Air Circulation: Hi CFM 400 (680) Clg 38 (540) Clg or Htg 359 (6) Clg or Htg (m3/h) 47 (800) Htg Medium CFM 34 (580) Clg 88 (490) Clg or Htg 3 (530) Clg or Htg (m3/h) 400 (680) Htg Low CFM 88 (490) Clg 59 (440) Clg or Htg 77 (470) Clg or Htg (m3/h) 34 (580) Htg Quiet CFM 4 (4) Clg 30 (390) Clg or Htg 4 (4) Clg or Htg (m3/h) 65 (450) Htg Fan Speed Stage 4+auto 4+auto 4+auto Sound Sound Level (Clg/Htg): Hi db(a) 33/34 37/37 40/44 Medium db(a) 3/3 33/33 36/40 Low db(a) 9/9 3/3 3/36 Quiet db(a) 8/7 8/8 8/30 Sound Level Clg/Htg db(a) 48/49 49/50 54/55 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 5 5 0 Current Rated: Cooling Amps 3.0 4.4 7. Current Rated: Heating Amps 4. 6.7 7.7 Power Use Rated/Max: Cooling kw 0.6/.40 0.94/.45.6/.5 Power Use Rated/Max: Heating kw 0.89/.80.44/.00.76/.60 Size & Weight Net Weight lbs. (kg) 33 (5) 84 (38) 33 (5) 84 (38) 33 (5) 86 (39) Inch 9-/ -5/ 4-/ 9-/ -5/ 4-/ 9-/ -5/ 4-/ mm 45 49 60 45 49 60 45 49 60 Inch -7/ 7-9/ 3-3/3-7/ 7-9/ 3-3/3-7/ 7-9/ 3-3/3 mm 570 700 790 570 700 790 570 700 790 Depth Inch -7/ 7-9/ -/3-7/ 7-9/ -/3-7/ 7-9/ -/3 mm 570 700 90 570 700 90 570 700 90 Refrigerant R4A R4A R4A Additional Data Air Direction: Vertical Automatic Automatic Automatic Air Filter Washable Washable Washable Minimum Lineset Length Ft (m) Maximum Lineset Length Ft (m) 66 (0) 66 (0) 66 (0) Max. Vertical Diff. Ft (m) 49 (5) 49 (5) 49 (5) Lineset Size Inch suc 3/8 dis /4 suc 3/8 dis /4 suc / dis /4 AUU9RLF Grille UTG-CCGF AOU9RLFC AUURLF Grille UTG-CCGF AOURLFC AUU8RLF Grille UTG-CCGF AOU8RLF Note: Figures are based on 30 Volts. 35

SINGLE-ZONE MINI-SPLITS 9,, 8,000 BTUh SLIM DUCT HEAT PUMPS HFI SYSTEMS 9RLFCD, RLFCD, 8RLFCD 9RLFCD RLFCD 8RLFCD UP TO.5 SEER FUNCTION Slim ducts provide cooling or heating for small room applications such as offices, restaurants, convenience stores, motels, dorms, in retrofit and new construction. Long maximum combined piping length of 66 and 49 in height allow for versatile installations. Either horizontal or vertical flexibility and low height enables compact soffit or cabinet installation. SLIM DUCT Built-in drain pump allows for installation of slim duct unit in smaller spaces than traditional units. Traditional 3 36 Pump Economy Daisy Minimum Heat Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wireless remote control. 3 Available only with optional Interface kit. Operation monitoring and On/Off control only. Bottom Drain Pump Slim Duct 9.4 RETURN AIR-INTAKE CHOICES Auto Changeover Adjust Restart Back FIELD SUPPLIED FILTERS USED WITH SLIM DUCT UNITS Although Slim Duct units come with factory filters, when return ductwork is used field supplied filters are more practical to use. They can be installed at the unit or for more convenient servicing, in filter grilles. See the guidelines to the right to determine filter sizes. The chart includes CFM, external static pressure capability and a typical filter size for each model. Filters are sized to keep velocities and static pressure loss low. This will ensure sufficient static pressure is available for ductwork, fittings and supply and return grilles. Alternative filter sizes with equivalent face areas can be used. After deducting filter loss, available static pressure values are shown. A fiberglass filter is shown in blue to the left. A MERV pleated filter is shown in white. Dry Fresh Quiet Mode Weekly Cold FLEXIBLE INSTALLATION Unit can be placed horizontally or vertically. However, internal drain pump will not operate when the unit is mounted in a vertical configuration. OPTIONAL ACCESSORIES 0% @ +5 F Wired Remote Control: UTY-RVNUM W ireless Remote and Receiver UTY-LRHUM Auto Louver Grille Kit UTD-GXSA-W(for ARU7/9/) UTD-GXSB-W (for ARU8) ARU 9RLF Sensor ARU RLF I/O 3rd Party ARU 8RLF CFM 353 383 547 Typical Filter Size x 0 x 0 4 x 5 Velocity, FPM 30 8 Unit External SP, in. 0.36 0.36 0.36 W.C. Fiberglass Filter SP Loss, in. W.C. 0.04 0.05 0.04 Available Static Pressure 0.3 0.3 0.3 MERV 8 Pleated Filter SP Loss, in. W.C. 0. 0.4 0.4 Available Static Pressure 0.4 0. 0. MERV 8 Pleated Filter SP Loss, in. W.C. 0.07 0.08 0.08 Available Static Pressure 0.9 0.8 0.8 3 Performance Nominal Cooling BTUh 9,000,000 8,000 Min.-Max. Cooling BTUh 3,0~,000 3,0~3,600 3,0~0,0 Nominal Heating BTUh,000,000,600 Min.-Max. Heating BTUh 3,0~8,000 3,0~9,400 3,0~5,600 SEER.5 0.0 9.7 HSPF..5.3 EER 4.5.8.0 Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) -5~75 (-~4) -5~75 (-~4) -5~75 (-~4) Moisture Removal Pt./h (l/h).5 (.07).7 (.3) 4. (.0) Fan Air Circulation: Hi CFM (m3/h) 353 (600) 383 (650) 554 (940) Medium CFM (m3/h) 34 (550) 353 (600) 58 (880) Low CFM (m3/h) 94 (500) 34 (550) 483 (80) Quiet CFM (m3/h) 65 (450) 83 (480) 44 (750) Fan Speed Stage 4+auto 4+auto 4+auto Sound Sound Level (Clg/Htg): Hi db(a) 8/8 9/9 3/3 Medium db(a) 7/6 8/8 30/30 Low db(a) 6/5 7/7 9/9 Quiet db(a) 5/4 6/4 7/7 Sound Level Clg/Htg db(a) 48/49 49/50 54/55 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 5 5 0 Current Rated: Cooling Amps 3.0 4.4 6.6 Current Rated: Heating Amps 3.9 6.0 7.3 Power Use Rated/Max: Cooling kw 0.6/.40 0.94/.45.50/.5 Power Use Rated/Max: Heating kw 0.85/.80.30/.00.67/.60 Size & Weight Net Weight lbs. (kg) 4 (9) 84 (38) 4 (9) 84 (38) 50 86 (39) Inch 7-5/3 5-5/ 6 4-/ 7-5/3 5-5/ 6 4-/ 7-5/3 5-5/ 6 4-/ mm 98 5 5 60 98 5 5 60 98 5 5 60 5-5- 33- Inch 7-9/ 3-3/3 7-9/ 3-3/3 35-7/ 9/3 9/3 5/3 30 3-3/3 mm 700 650 559 790 700 650 559 790 900 850 76 790 4- - 4- - 4- - Inch 3/4 3/4 Flat 3/4 3/4 Flat 3/4 3/4 Flat Depth 3/3 /3 3/3 /3 3/3 /3 mm 60 9 9 Flat 90 60 9 9 Flat 90 60 9 9 Flat 90 Refrigerant R4A R4A R4A Additional Data Static Pressure in. W. C. 0 ~ 0.36 0 ~ 0.36 0 ~ 0.36 Air Filter Washable Washable Washable Minimum Lineset Length Ft (m) Maximum Lineset Length Ft (m) 66 (0) 66 (0) 66 (0) Max. Vertical Diff. Ft (m) 49 (5) 49 (5) 49 (5) Lineset Size Inch suc 3/8 dis /4 suc 3/8 dis /4 ARU9RLF SUPPLY DUCT FLANGE RETURN DUCT AOU9RLFC ARURLF SUPPLY DUCT FLANGE RETURN DUCT AOURLFC suc / ARU8RLF SUPPLY DUCT FLANGE RETURN DUCT dis /4 AOU8RLF Note: Figures are based on 30 Volts. 37

SINGLE-ZONE MINI-SPLITS 8, 4, 36,000 BTUh CEILING & UNIVERSAL HEAT PUMPS SYSTEMS 8RULX, 4RULX, 36RSLX UP TO SEER 8RULX 4RULX 36RSLX Pump Down Saving Sensor Auto Changeover 0 F Cooling Daisy Adjust 4-Way Restart 4+ ft Piping Dry Fresh Available only with optional wired remote control. Fresh air knockout available. Fresh air fan and ductwork field supplied. See Design and Technical Manual for details. APPLICATIONS The universal floor/ceiling mount 8RULX and 4RULX are ideal for a house of worship to mount beneath stained glass windows. Lower in height than the pews, they do not disturb the aesthetics of the space. With long piping lengths of 5 the outdoor units can also be placed remotely out of sight. Another popular application for this model is in hallways where wall space is limited. The 36RSLX is popular where fresh air intake and high capacity is required like a restaurant or bar. They are also often suspended from threaded rod and used in multiple to condition large warehouse spaces. FUNCTION 4 Hour Sleep Weekly The 8RULX and the 4RULX are universal mount. They can mount low on the wall or transverse mount them on the ceiling. The 36RSLX can only be mounted on the ceiling, can take in fresh air and can throw air farther. OPTIONAL ACCESSORIES Wired Remote Control UTY-RNBYU* Weekly Timer Full Function Wired Remote Child Lock Capable *Requires dip switch change on indoor unit. Condensate Pump UTR-DPB4T OEM design plug and play Rated for.8 of vertical lift. Available only for System 36RSLX. Cold Ceiling Performance Nominal Cooling BTUh 7,800,00 34,0 Min.-Max. Cooling BTUh 5,000~,600 5,000~7,300 8,500~36,000 Nominal Heating BTUh,500 4,000 36,500 Min.-Max. Heating BTUh 5,000~5,600 5,000~9,000 9,00~4,700 SEER.0 5.0 4.0 HSPF 8.5 8.5 8.5 EER.9 9.9 8. Cooling Operating Range F ( C) 0~5 (-8~46) 0~5 (-8~46) 0~5 (-8~46) Heating Operating Range F ( C) 4~75 (-~4) 4~75 (-~4) 4~75 (-~4) Moisture Removal Pt./h (l/h) 5.3 (.5) 7.4 (3.5) 7.4 (3.5) Fan Air Circulation: Hi CFM (m3/h) 459 (780) 58 (880) 89 (850) Medium CFM (m3/h) 383 (650) 436 (740) 977 (60) Low CFM (m3/h) 34 (550) 37 (630) 84 (430) Quiet CFM (m3/h) Fan Speed Stage 3 + Auto 3 + Auto 3 + Auto Sound Sound Level (Clg/Htg): Hi db(a) 43/43 (Clg/Htg) 47/47 (Clg/Htg) 48/48 (Clg/Htg) Medium db(a) 39/39 (Clg/Htg) 43/43 (Clg/Htg) 45/43 (Clg/Htg) Low db(a) 35/35 (Clg/Htg) 38/38 (Clg/Htg) 4/39 (Clg/Htg) Quiet db(a) Sound Level Clg/Htg db(a) 5/53 53/55 54/55 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 0 0 30 Current Rated/Max: Cooling Amps 7./.5 9.8/.5 8.3/8.8 Current Rated/Max: Heating Amps 9.8/.5./.5 5.3/8.8 Power Use Rated/Max: Cooling kw.63/.88.5/.88 4./4.35 Power Use Rated/Max: Heating kw.5/.88.35/.88 3.50/4.35 Size & Weight Net Weight lbs. (kg) 6 (8) 4 (64) 6 (8) 4 (64) 6 (48) 4 (64) Depth Inch 7-7/8 3-3/4 7-7/8 3-3/4 9-/ 3-3/4 mm 99 830 99 830 40 830 Inch 39-/8 35-/ 39-/8 35-/ 65-/ 35-/ mm 990 900 990 900 60 900 Inch 5-7/8 3 5-7/8 3 7-5/8 3 mm 655 330 655 330 700 330 Refrigerant R4A R4A R4A Additional Data Air Direction: Horizontal Automatic Automatic Automatic Vertical Automatic Automatic Automatic Air Filter Washable Washable Washable Front Grille Permanent Permanent Permanent Minimum Lineset Length Ft (m) (5) (5) (5) Maximum Lineset Length Ft (m) 5 (50) 5 (50) 5 (50) Max. Vertical Diff. Ft (m) 66 (0) 66 (0) 98 (30) Lineset Size Inch Suc./ Dis. /4 Suc.5/8 Dis. 3/8 Suc.5/8 Dis. 3/8 ABU8RULX AOU8RLX ABU4RULX AOU4RLX ABU36RSLX AOU36RLX Note: Figures are based on 30 Volts. 38 39

SINGLE-ZONE MINI-SPLITS 8, 4, 36, 4,000 BTUh LARGE CASSETTE HEAT PUMPS SYSTEMS 8RCLX, 4RCLX, 36RCLX, 4RCLX UP TO.0 SEER 8RCLX 4RCLX 36RCLX 4RCLX Branch Pump Fresh air knockout available. Fresh air fan and ductwork field supplied. See design and technical manual for details. Fujitsu fresh air intake kit available part #KHRS940-5. FUNCTION Up to -SEER, these models provide up to 30% increase in efficiency over 3-SEER models. These models offer the ability to send up to 38% of their capacity through two branch ducts to adjacent rooms. Slender fit feature now offered on all models decreases space required above the ceiling increasing application opportunities. SLENDER FIT Auto Saving Changeover Daisy Adjust Up/Down Restart 4+ ft Piping Slender Cassette body can be moved downward into the room -3/8 to accommodate limited ceiling space. Fujitsu provides knock-outs on all ceiling cassettes where contractors can: Install optional field supplied branch ducts on up to two sides to supply up to 8% capacity per side to adjoining spaces up to feet away. See Design and Technical Manual for details. Allows fresh air to be brought into the indoor unit using fresh air knockout. Dry Fresh Weekly APPLICATIONS Cold Ceiling Four-way airflow, concealed flush mount design and the ability to operate in high ceiling rooms makes these systems ideal for commercial applications such as offices, conference rooms, restaurants, night clubs and bars in retrofit and new construction. Long maximum combined piping lengths of 5 to 30 feet with 60 to 98 feet of height, depending on model, allow the outdoor unit to be remotely located up to 7 stories away and far from indoor unit. The ceiling cassettes are also used in new construction condominiums and homes taking advantage of their branch duct capability to feed adjacent rooms. These heat pumps provide up to 30% additional available heat when compared to conventional models. Pump Down Sensor 0 F Cooling Performance Nominal Cooling BTUh 7,800,00 34,0 4,700 Min.-Max. Cooling BTUh 5,000~,500 5,000~7,300 8,500~36,000 3,700~45,000 Nominal Heating BTUh,000 4,00 36,000 45,00 Min.-Max. Heating BTUh 5,000~5,600 5,000~9,000 9,00~4,700 4,300~54,600 SEER.0 5.0 4.0 5.0 HSPF 8.5 8.5 8.5 8.5 EER..6 8. 9. Cooling Operating Range F ( C) 0~5 (-8~46) 0~5 (-8~46) 0~5 (-8~46) 0~5 (-8~46) Heating Operating Range F ( C) 4~75 (-~4) 4~75 (-~4) 4~75 (-~4) 0~75 (-8~4) Moisture Removal Pt./h (l/h) 5.3 (.5) 6.4 (3.0) 8.5 (4.0).6 (5.5) Fan Air Circulation: Hi CFM (m3/h) 559 (950) 68 (,050) 94 (,600),000 (,700) Medium CFM (m3/h) 477 (8) 536 (9) 84 (,400) 854 (,450) Low CFM (m3/h) 394 (670) 436 (740) 677 (,50) 736 (,50) Fan Speed Stage 3 + Auto 3 + Auto 3 + Auto 3 + Auto Sound Sound Level (Clg/Htg): Hi db(a) 4/40 (Clg/Htg) 45/43 (Clg/Htg) 48/48 (Clg/Htg) 50/50 (Clg/Htg) Medium db(a) 39/38 (Clg/Htg) 43/39 (Clg/Htg) 45/45 (Clg/Htg) 48/48 (Clg/Htg) Low db(a) 36/36 (Clg/Htg) 38/35 (Clg/Htg) 4/4 (Clg/Htg) 44/44 (Clg/Htg) Sound Level Clg/Htg db(a) 5/53 (Clg/Htg) 53/55 (Clg/Htg) 54/55 (Clg/Htg) 55/56 (Clg/Htg) Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Circuit Breaker Amps 0 0 30 30 Current Rated/Max: Cooling Amps 7.0/.5 9./.5 8.3/8.8 0.3/.7 Current Rated/Max: Heating Amps 8.9/.5.4/.5./8.8 8.8/.7 Power Use Rated/Max: Cooling kw.6/.88./.88 4./4.35 4.66/4.99 Power Use Rated/Max: Heating kw.05/.88.37/.88 3.70/4.35 4.3/4.99 Size & Weight Net Weight lbs. (kg) Suc. / Dis. /4 Suc. 5/8 Dis. 3/8 Suc. 5/8 Dis. 3/8 Suc. 5/8 Dis. 3/8 Inch 75 (34) 4 (64) 75 (34) 4 (64) 8 (37) 4 (64) 88 (40) 3 (5) mm 9-3/4 3-3/4 9-3/4 3-3/4-5/8 3-3/4-5/8 50-7/8 Inch 46 830 46 830 96 830 96 90 mm 3-3/4 35-/ 3-3/4 35-/ 3-3/4 35-/ 3-3/4 35-/ Depth Inch 830 900 830 900 830 900 830 900 mm 3-3/4 3 3-3/4 3 3-3/4 3 3-3/4 3 Refrigerant 830 330 830 330 830 330 830 330 Additional Data Air Direction: Horizontal - - - - Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Front Grille Removable Removable Removable Removable Minimum Lineset Length Ft (m) (5) (5) (5) (5) Maximum Lineset Length Ft (m) 5 (50) Each 5 (50) Each 5 (50) Each 30 (70) Each (pre-charge: 66) Max. Vertical Diff. Ft (m) 66 (0) 66 (0) 98 (30) 98 (30) Lineset Size Inch Suc. / Dis. /4 Suc. 5/8 Dis. 3/8 Suc. 5/8 Dis. 3/8 Suc. 5/8 Dis. 3/8 AUU8RCLX AOU8RLX AUU4RCLX AOU4RLX AUU36RCLX AOU36RLX AUU4RCLX AOU4RLX Note: Figures are based on 30 Volts. 40 4

MULTI-ZONE MINI-SPLITS MULTI-ZONE MINI-SPLIT SYSTEMS Operate as few as one indoor unit or all indoor units Choose from 4 indoor unit styles - wall mount, slim duct, compact cassette, and floor mount Six combinations are ENERGY STAR qualified Create hundreds of combinations based on indoor type and BTUh Connect to 5 indoor units, depending on model Connect 4,000 to 54,000 BTUh No branch boxes or separation tubes required 8, 4, 36,000 BTUh Connect to 4 indoor units, depending on model Connect 4,000 to 39,000 BTU extra Low Temp Heating down to outdoor temps No branch boxes or separation tubes required Connect to 8 indoor units 80 to 30% connectable capacity Connect 39,000 to 6,000 BTU Branch boxes and separation tubes required YEAR-ROUND, WHOLE HOME OR BUSINESS COMFORT Halcyon Systems are some of today s most advanced forms of heating and air conditioning. Multi-zone outdoor units can operate from to 8 indoor units simultaneously. Fujitsu s systems are super quiet as well as highly energy efficient. MULTI-ZONE AND XLTH SERIES SYSTEMS 8, 4, 36, AND 45,000 BTUh AOU8RLXFZ AOU4RLXFZ AOU36RLXFZ AOU45RLXFZ AOU8RLXFZH AOU4RLXFZH AOU36RLXFZH CONNECTABLE CAPACITY This allows connectable indoor units total capacity to exceed outdoor unit capacity. See Allowable Combination Table on page 64. If all indoor units are cooling or heating at the same time, the system will limit their capacity so that their total matches the outdoor unit s capacity. When a zone meets a desired set temperature it requires less capacity. The unused capacity is then distributed to the remaining indoor units, increasing their capacity. FOR EXAMPLE The load on a 3-bedroom home with a living room and kitchen downstairs and 3 bedrooms upstairs is 39,000 BTUh (,000 BTU downstairs and 8,000 BTU upstairs). However the family isn t upstairs and downstairs at the same time, therefore not all units will be running simultaneously allowing 0% heating or cooling to occupied spaces. This can be achieved by our AOU36RLXFZ outdoor unit. HFI SERIES SYSTEM 48,000 BTUh AOU48RLXFZ 30% CONNECTABLE CAPACITY The HFI system is rated at 48,000 BTUh but you can connect up to 30%, or 6,000 BTUh of rated indoor unit capacity to the AOU48RLXFZ. Connectable capacity allows you to connect indoor units that can exceed outdoor unit capacity. However, if you connect indoor units that exceed 0% of the outdoor unit s capacity there are limitations. If all indoor units are cooling or heating at the same time, the system will limit their capacity so that their total matches the outdoor unit s capacity. When a zone meets a desired set temperature it requires less capacity. The unused capacity is then distributed to the remaining indoor units, increasing their capacity. FOR EXAMPLE The load on a small -story office building with a business downstairs and worker apartments upstairs is 6,000 BTUh (38,000 BTUh downstairs and 4,000 BTUh upstairs) but the workers aren t upstairs and downstairs at the same time, therefore not all units will be running simultaneously allowing 0% heating or cooling to occupied spaces. 4 43

MULTI-ZONE MINI-SPLITS MIX AND MATCH FLEXIBILITY INDIVIDUAL ZONING: PERSONALIZED WHOLE HOME COMFORT The ability to create the right combinations, the right quantity (up to 8-zones), the right style indoor units, and the right capacity. It s the RIGHT choice for your home or business. MULTI-ZOME INDOOR UNITS WALL MOUNTS ASU7, 9, RLF ASU5RLF ASU8RLF ASU4RLF FLOOR MOUNTS AGU9, RLF AGU5RLF SLIM DUCTS ARU7, 9, RLF ARU8RLF ARU4RLF COMPACT CASSETTES AUU7, 9, RLF AUU8RLF OTHER SEPARATION TUBES: UTP-SX48A BRANCH BOXES: UTP-PU03A, B WALL MOUNTED They mount high on a wall, out of sight and do not require ductwork, increasing energy efficiency. Quiet operation Easy maintenance High delivered efficiency means lower utility bills COMPACT CASSETTE Cassettes are extremely discreet, with only the grille showing in the ceiling. They use the latest fan technology to distribute the conditioned air evenly. Wired remote control (wireless is optional) Powerful turbo fan operation Fits into a standard x ceiling grid SLIM DUCT Mounted in a ceiling or in a framed enclosure below a ceiling. They use minimal ductwork and remain very energy efficient. Concealed and out of sight Look of central air with the efficiency of a mini-split Less ducts = higher efficiency AOU8RLXFZ AOU4RLXFZ AOU36RLXFZ AOU45RLXFZ AOU48RLXFZ AOU8RLXFZH AOU4RLXFZH AOU36RLXFZH MULTI-ZONE OUTDOOR UNITS FLOOR MOUNTED Floor mount systems are ideal for residential radiator replacements or any room with limited upper wall space, like a kitchen or sunroom. Compact size fits easily under a standard window Features twin airflow for improved heat delivery Designer wireless remote control 44 45

MULTI-ZONE MINI-SPLITS 7, 9,, 5, 8, 4,000 BTUh WALL MOUNT HFI ASU7RLF, ASU9RLF, ASURLF, ASU5RLF, MULTI-ZONE INDOOR ASU8RLF, ASU4RLF Auto Economy Minimum Heat Changeover Cold Ion Sensor Adjust 4-Way 6 I/O 3rd Party 7 Daisy Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. ASU7, 9,, 5RLF 3 Up/Down 4 4+ ft 8 Piping Restart ASU8, 4RLF Dry Quiet Mode 4 Hour Sleep Weekly 3 RLF models only. 4 RLF models only. 5 RLF models: Available only with optional wired remote control. 6 Available only with optional wired remote control and optional interface kit. 7 Available only with optional interface kit. 8 Available only when used with Flex Zone AOU48RLXFZ outdoor unit. 5 ASU7RLF ASU9RLF ASURLF ASU5RLF ASU8RLF ASU4RLF Performance Nominal Cooling BTUh 7,000 9,000,000 4,000 8,000 4,000 Nominal Heating BTUh 8,0,00 3,500,300 0,000 7,000 Fan Air Circulation: Hi CFM Clg 330 (560) Clg 353 (600) Clg 388 (660) Clg 430 (730) Clg 54 (90) Clg 659 (,0) (m3/h) Htg 330 (560) Htg 353 (600) Htg 388 (660) Htg 430 (730) Htg 54 (90) Htg 647 (,0) Medium CFM Clg 94 (500) Clg 306 (50) Clg 330 (560) Clg 353 (600) Clg 436 (740) Clg 530 (900) (m3/h) Htg 94 (500) Htg 306 (50) Htg 330 (560) Htg 36(65) Htg 436 (740) Htg 530 (900) Low CFM Clg 53 (430) Clg 53 (430) Clg 65 (450) Clg 3 (530) Clg 365 (60) Clg 436 (740) (m3/h) Htg 53 (430) Htg 53 (430) Htg 77 (470) Htg 330 (560) Htg 365 (60) Htg 436 (740) Quiet CFM Clg 8 Clg 8 Clg 8 Clg (360) Clg 34 (550) Clg 365 (60) (m3/h) Htg 94 (330) Htg 94 (330) Htg 94 (330) Htg (375) Htg 34 (550) Htg 365 (60) Fan Speed Stage 4+auto 4+auto 4+auto 4+auto 4+auto 4+auto Sound Sound Level (Clg/Htg): Hi db(a) 36/36 37/37 40/40 4/4 43/44 49/48 Medium db(a) 3/3 33/33 36/36 38/38 37/37 4/4 Low db(a) 9/9 9/9 30/3 33/35 33/33 37/37 Quiet db(a) / / / 5/7 3/3 33/33 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Current Rated: Cooling Amps 0.3 0.5 0.9 0.5 0.3 0.53 Current Rated: Heating Amps 0.3 0.5 0.9 0.5 0.3 0.53 Power Use Rated: Cooling W 5 7 8 4 69 Power Use Rated: Heating W 5 7 8 4 69 Size & Weight Net Weight lbs. (kg) 9 (8.5) 9 (8.5) 9 (8.5) 9 (8.5) 3 (4) 3 (4) Inch -/ -/ -/ -/ -5/8-5/8 mm 68 68 68 68 30 30 Inch 33-/ 33-/ 33-/ 33-/ 39-/4 39-/4 mm 840 840 840 840 998 998 Depth Inch 8 8 8 8 9 9 mm 03 03 03 03 8 8 Refrigerant R4A R4A R4A R4A R4A R4A Additional Data Air Direction: Horizontal Manual Manual Manual Manual Auto Auto Vertical Auto Auto Auto Auto Auto Auto Primary Air Filter Washable Washable Washable Washable Washable Washable Ion Deodorizing Filter Disposable Disposable Disposable Disposable Disposable Disposable Apple-Catechin Filter Disposable Disposable Disposable Disposable Disposable Disposable Lineset Size Inch suc 3/8 suc 3/8 suc 3/8 suc /4 dis / suc / suc 5/8 BUILT IN FILTRATION LONG-LIFE ION DEODORIZATION FILTER The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic. The filter can be used for approximately 3 years if it is washed with water when dirty to restore its surface action. APPLE-CATECHIN FILTER Dust, mold spores and micro-organisms are absorbed onto the filter by static electricity and growth is inhibited and deactivated. The following combinations are ENERGY STAR qualifying: AOU8RLXFZ with () ASU9RLF AOU8RLXFZ with () ASU7RLF + () ASURLF AOU8RLXFZ with () ASU9RLF + () ASURLF AOU8RLXFZH with () ASU9RLF AOU4RLXFZ with () ASU7RLF + () ASU9RLF AOU4RLXFZH with () ASU7RLF + () ASU9RLF AOU36RLXFZH with (4) ASU9RLF 46 47

MULTI-ZONE MINI-SPLITS 7, 9,, 8, 4,000 BTUh SLIM DUCT MULTI-ZONE INDOOR HFI ARU7RLF, ARU9RLF, ARURLF, ARU8RLF, ARU4RLF ARU7RLF ARU9RLF ARURLF ARU8RLF ARU4RLF Economy Minimum Heat Auto Changeover 3 Adjust Restart Dry Quiet Mode 4 Hour Sleep Weekly Cold Sensor Performance Nominal Cooling BTUh 7,000 9,000,000 8,000 4,000 Nominal Heating BTUh 8,0,00 3,500 0,000 7,000 Fan Air Circulation: Hi CFM (m3/h) 33 (550) 353 (600) 383 (650) 554 (940) 783 (,330) Medium CFM (m3/h) 88 (490) 34 (550) 353 (600) 58 (880) 730 (,40) I/O 3rd Party 4 Pump Daisy FLEXIBLE INSTALLATION 4+ ft 5 Piping Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available only with optional wireless remote control. 3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 4 Availabe lonly with optional interface kit. 5 Available only when used with Flex Zone AOU48RLXFZ outdoor unit. Horizontal or vertical, though internal drain pump will not operate when the unit is mounted in a vertical configuration. FIELD SUPPLIED FILTERS Filters are sized to keep velocities and static pressure loss low. This will ensure sufficient static pressure is available for ductwork, fittings and supply and return grilles. Alternative filter sizes with equivalent face areas can be used. SLIM DUCT Adaptable when ceiling cavity is small and there is no slope for drain. Traditional 3 Drain Pump Compact Duct 9.4 ARU7RLF ARU9RLF ARURLF ARU8RLF ARU4RLF CFM 33 353 383 554 785 Typical Filter Size x 0 x 0 x 0 4 x 5 8 x 30 Velocity, FPM 94 30 8 09 Unit External SP, in. W.C. 0.36 0.36 0.36 0.36 0.0 Fiberglass Filter SP Loss, in. W.C. 0.04 0.04 0.05 0.04 0.04 Available Static Pressure 0.3 0.3 0.3 0.3 0. MERV 8 Pleated Filter SP Loss, in. W.C. 0. 0. 0.4 0.4 0. Available Static Pressure 0.6 0.4 0. 0. 0.08 MERV 8 Pleated Filter SP Loss, in. W.C. 0.06 0.07 0.08 0.08 0.07 Available Static Pressure 0.30 0.9 0.8 0.8 0.3 Low CFM (m3/h) 76 (470) 94 (500) 34 (550) 483 (80) 648 (,0) Quiet CFM (m3/h) 59 (440) 65 (450) 83 (480) 44 (750) 607 (,030) Fan Speed Stage 4 + Auto 4 + Auto 4 + Auto 4 + Auto 4 + Auto Sound Sound Level (Clg/Htg): Hi db(a) 8/8 8/8 9/9 3/33 33/35 Medium db(a) 6/6 7/6 8/8 3/3 3/34 Low db(a) 5/5 6/5 7/7 30/3 30/3 Quiet db(a) 4/4 5/4 6/4 9/9 9/9 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Static Pressure W. C. 0 ~ 0.36 0 ~ 0.36 0 ~ 0.36 0 ~ 0.36 0 ~ 0.0 Current Rated: Cooling Amps 0.30 0.30 0.35 0.44 0.66 Current Rated: Heating Amps 0.30 0.30 0.35 0.44 0.66 Power Use Rated: Cooling W 33 49 58 73 Power Use Rated: Heating W 33 49 58 73 Size & Weight Net Weight lbs. (kg) 37 (7) 4 (9) 4 (9) 50 59 (7) Inch 7-5/3 7-5/3 7-5/3 7-5/3 7-5/3 mm 98 98 98 98 98 Inch 7-9/ 7-9/ 7-9/ 35-7/ 43-5/ mm 700 700 700 900,0 Depth Inch 4-3/3 4-3/3 4-3/3 4-3/3 4-3/3 mm 60 60 60 60 60 Supply Duct Flange Inch 5-5/ 5-5/ 5-5/ 5-5/ 5-5/ mm 5 5 5 5 5 Inch 5-9/3 5-9/3 5-9/3 33-5/3 4-/3 mm 650 650 650 850,050 Depth Inch 3/4 3/4 3/4 3/4 3/4 mm 9 9 9 9 9 Return Duct Inch 6 6 6 6 6 mm 5 5 5 5 5 Inch 30 37-3/4 mm 559 559 559 76 959 Height Inch 3/4 (Flat) 3/4 (Flat) 3/4 (Flat) 3/4 (Flat) 3/4 (Flat) mm 9 (Flat) 9 (Flat) 9 (Flat) 9 (Flat) 9 (Flat) Refrigerant R4A R4A R4A R4A R4A Additional Data Air Filter Washable Washable Washable Washable Washable Lineset Size Inch suc 3/8 dis /4 suc 3/8 dis /4 suc 3/8 dis /4 suc / dis /4 suc 5/8 dis /4 48 49

MULTI-ZONE MINI-SPLITS 7, 9,, 8,000 BTUh COMPACT CASSETTES MULTI-ZONE INDOOR HFI AUU7RLF, AUU9RLF, AUURLF, AUU8RLF AUU7RLF AUU9RLF AUURLF AUU8RLF Cold Economy Minimum Heat Ceiling Sensor Applies when properly registered AND installed by a Fujitsu Elite Contractor in residence. See full warranty for details. Available only with optional wireless remote control. 3 Auto Changeover is not designed to provide rapid changes between heating and cooling operation or simultaneous heating and cooling. This feature is not recommended for systems with more than one indoor unit unless all indoor units have similar heating and cooling requirements and have similar temperature set points. If all indoor units have similar heating and cooling requirements and have similar temperature set points, auto changeover will work. 4 Requires Fujitsu s Optional Fresh Air Kit part #UTZ-VXAA. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at. W.C. or 90 CFM at.4 W.C. For fan static pressure requirements, see installation manual. Add hood, filter and duct losses for fan total static pressure requirements. Will add 4 to the height of the indoor unit. 5 Available only with optional Interface kit. Operation monitoring and On/Off control only. 6 Available only when used with Flex Zone AOU48RLXFZ outdoor unit. EASY INSTALLATION Auto Changeover I/O 3rd Party Fits into a standard ceiling tile. Dimensions of outer grille are 7-9/ x 7-9/ and may overlap adjacent tiles. 3 5 Adjust Up/Down Restart Pump Daisy.5.5 4+ ft 6 Piping Dry Fresh -STAGE TURBO FAN 4 Quiet Mode 4 Hour Air distribution is evenly spread across the heat exchanger by the stage turbo fan which produces two separate airflow streams. Heat exchange efficiency: Increased 0% Sleep -stage -stage Weekly Performance Nominal Cooling BTUh 7,000 9,000,000 8,000 Nominal Heating BTUh 8,0,00 3,500 0,000 Fan Air Circulation: Hi Medium Low Quiet CFM (m3/h) CFM (m3/h) CFM (m3/h) CFM (m3/h) 38 (540) Clg or Htg 88 (490) Clg or Htg 59 (440) Clg or Htg 30 (390) Clg or Htg 38 (540) Clg or Htg 88 (490) Clg or Htg 59 (440) Clg or Htg 30 (390) Clg or Htg 359 (6) Clg or Htg 3 (530) Clg or Htg 77 (470) Clg or Htg 4 (4) Clg or Htg 44 (750) Clg 47 (800) Htg 359 (6) Clg 48 (7) Htg 306 (50) Clg 353 (600) Htg 4 (4) Clg 65 (450) Htg Fan Speed Stage 4+auto 4+auto 4+auto 4+auto Sound Sound Level (Clg/Htg): Hi db(a) 33/34 33/34 37/37 4/44 Medium db(a) 3/3 3/3 33/33 37/40 Low db(a) 9/9 9/9 3/3 33/37 Quiet db(a) 7/7 7/7 8/8 9/30 Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Current Rated: Cooling Amps 0.5 0.5 0.9 0.30 Current Rated: Heating Amps 0.5 0.5 0.9 0.30 Power Use Rated/Max: Cooling (kw) 8 8 3 39 Power Use Rated/Max: Heating (kw) 8 8 3 39 Size & Weight Net Weight lbs. (kg) 33 (5) 33 (5) 33 (5) 33 (5) Inch 9-/ 9-/ 9-/ 9-/ mm 45 45 45 45 Inch -7/ -7/ -7/ -7/ mm 570 570 570 570 Depth Inch -7/ -7/ -7/ -7/ mm 570 570 570 570 Refrigerant R4A R4A R4A R4A Additional Data Air Direction: Vertical Automatic Automatic Automatic Automatic Air Filter Washable Washable Washable Washable Front Grille UTG-CCGF* UTG-CCGF* UTG-CCGF* UTG-CCGF* Grille Dim: Height Inch (mm) -5/ (49) -5/ (49) -5/ (49) -5/ (49) Inch (mm) 7-9/ (700) 7-9/ (700) 7-9/ (700) 7-9/ (700) Depth Inch (mm) 7-9/ (700) 7-9/ (700) 7-9/ (700) 7-9/ (700) Lineset Size Inch suc 3/8 dis /4 suc 3/8 dis /4 suc 3/8 dis /4 suc / dis /4 * Compact Cassette Grille UTG-CCGF sold separately. Must order one with each compact cassette. Fresh Air Kit** UTZ-VXAA Mixes room air then passes through the heat exchanger. 50 5

MULTI-ZONE MINI-SPLITS 9,, 5,000 BTUh FLOOR MOUNT HFI AGU9RLF, AGURLF, AGU5RLF MULTI-ZONE INDOOR AGU9RLF AGURLF AGU5RLF Auto Economy Minimum Heat Changeover Cold Ion Sensor I/O 3rd Party -FAN AND WIDE AIRFLOW Adjust Up/Down Restart Having both upper and lower airflow quickly warms or cools the entire room. Floor mount can be set in Upward Airflow Only when occupants wish not to have feet warmed or cooled. 3 Daisy Cooling Heating Window Fig. Fig. Fig. Fig.. Upon startup, both top and bottom louvers open.. As the room temperature nears the setpoint, only the top louver stays open to help prevent cold air from falling. Dry Powerful Quiet Mode 4 Hour Sleep Weekly Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. Available with optional wired remote control. 3 Available only with optional Interface kit. Operation monitoring and On/Off control only.. Upon startup, both top and bottom louvers open.. Closer to setpoint, only the top louver stays open to help prevent cold drafts from windows. FLEXIBLE AND EASY INSTALLATION 3-5/8 Beneath standard window 9-/8 Wall Max. 5-7/8 7-7/8 7-9/ Min. 7-9/ Min. 3- /4 Standard concave portion Min. 37 Half concealed* Min. 8-3/4 Max. 3-/8 Performance Nominal Cooling BTUh 9,000,000 4,00 Nominal Heating BTUh,000,000 8,000 Fan Air Circulation: Hi CFM (m3/h) 3 (530) 353 (600) 383 (650) Medium CFM (m3/h) 59 (440) 88 (490) 306 (50) Low CFM (m3/h) (360) 4 (380) 35 (400) Quiet CFM (m3/h) 59 (70) 59 (70) 59 (70) Fan Speed Stage 4+Auto 4+Auto 4+Auto Sound Sound Level (Clg/Htg): Hi db(a) 39/39 4/4 44/44 Medium db(a) 34/34 36/38 38/39 Low db(a) 8/8 30/3 3/33 Quiet db(a) / / / Electrical Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ Current Rated: Cooling Amps 0.5 0.8 0.0 Current Rated: Heating Amps 0.5 0.8 0.0 Power Use Rated: Cooling (kw) 8 3 Power Use Rated: Heating (kw) 8 3 Size & Weight Net Weight lbs. (kg) 3 (4) 3 (4) 3 (4) Inch 3-5/8 3-5/8 3-5/8 mm 600 600 600 Inch 9-/8 9-/8 9-/8 mm 740 740 740 Depth Inch 7-7/8 7-7/8 7-7/8 mm 00 00 00 Refrigerant R4A R4A R4A Additional Data Air Direction: Horizontal Manual Manual Manual Air Direction: Vertical Auto Auto Auto Apple Catechin Filter Washable Washable Washable Ion Deoderizing Filter Yes Yes Yes Connection Method Yes Yes Yes Lineset Size Inch Suc. 3/8 Dis. /4 Suc. 3/8 Dis. /4 Suc. / Dis. /4 * Field supplied insulation required 5 53

FEATURES MULTI-ZONE MINI-SPLITS 8, 4, 36, 45,000 BTUh MULTI-ZONE OUTDOOR UNITS HFI AOU8RLXFZ, AOU4RLXFZ, AOU36RLXFZ, AOU45RLXFZ Contractors can select either an 8, 4, 36 or 45,000 BTU outdoor unit combined with wall mounted, slim duct, compact cassette or floor mount type indoor units. Mixand-match flexibility of evaporator type and capacity allows you to choose the indoor unit that best fits the application, whether it be hidden or showcased. These systems are ideal for nursing homes, doctor s offices, condominiums, apartments and residences - any place where individual cooling or heating is needed. DC TWIN ROTARY COMPRESSORR A high performance, low noise, large capacity DC twin rotary compressor is used. 54 unit NOMINAL CAPACITIES, SEER AND HSPF RATINGS Data below is based on AHRI /40 non-ducted wall mounted models. Yellow rows represent systems that are ENERGY STAR qualified. Model AOU8RLXFZ AOU4RLXFZ AOU36RLXFZ AOU45RLXFZ AOU8, 4RLXFZ COMPACT SIZE AOU36RLXFZ AOU45RLXFZ The compact size of the outdoor units allows for many installation opportunities. 4 minimum clearance required Unit Cooling Heating Rated Heating Maximum COP Capacity Btu/h EER SEER Capacity Btu/h Capacity Btu/h HSPF Type Combination 95F 47F 7F 7F 5F 47F Non-Ducted 9+9 8,000.5 8.0,000 3,900,300 3,900 3.44 9.3 Ducted 9+9 8,000..0,000 3,900,300 3,900 3.5 9.0 Mixed 9+9 8,000.3 7.0,000 3,900,300 3,900 3.48 9. Specific ASU7+ASU and ASU9+ASU 8,000.5 8.0,000 3,900,300 3,900 3.67 9.0 Non-Ducted 9+7+7,000.5 8.0 4,000 4,0 9,800,300 4.04 9.5 Ducted 9+7+7,000.6 5.5 4,000 4,0 9,800,300 3.4 9.0 Mixed 9+7+7,000.6.8 4,000 4,0 9,800,300 3.74 9.3 Non-Ducted 9+9+9+9 35,00.0 8.0 4,000,000 3,500 5,400 3.56 9.4 Ducted 9+9+9+9 35,00 9.0.0 4,000,000 3,500 5,400 3.3 8.7 Mixed 9+9+9+9 35,00 9.5 7.0 4,000,000 3,500 5,400 3.44 9. Non-Ducted 9+9+9+9+9 45,000.5 9.7 48,000 8,00 36,900 3,500 3.60.3 Ducted 9+9+9+9+9 45,000 9.8 7.7 46,000 7,800 36,900 3,500 3.46 9.3 Mixed 9+9+9+9+9 45,000. 8.7 47,000 8,000 36,900 3,500 3.53 9.8 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. AOU8RLXFZ ASU9+ASU9 AOU4RLXFZ ASU9+ASU7+ASU7 AOU36RLXFZ ASU9 x 4 AOU45RLXFZ ASU9 x5 Performance Connectable Units to 3 * to 4 to 5 Connectable Unit Capacity Class BTUh 4 to,000 4 to 7,000 7 to 39,000 34 to 54,000 Rated Capacity Cooling / Heating BTUh 8,000 /,000,000 / 4,000 35,00 / 36,400 45,000 / 48,000 Cooling Operating Range F ( C) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) 4~5 (-~46) Heating Operating Range F ( C) 5~75 5~75 5~75 5~75 (-5~4) (-5~4) (-5~4) (-5~4) Electrical Rated Input Power Clg/Htg kw.44/.87.76/.73 3.5/3.00 4.8/3.88 Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ 08-30/60/ Maximum Total Current Amps.0 3.7 0.3 3.8 Minimum Circuit Ampacity Amps..7 4.6 8.9 Maximum Circuit Breaker Amps 5 0 30 30 Fan: Type x Quantity Propeller x Propeller x Propeller x Propeller x Sound Pressure Level Cooling db(a) 49 5 53 53 Sound Pressure Level Heating db(a) 49 5 55 55 Lineset Requirements Minimum Lineset Length Each ft(m) (5) (5) (5) (5) Maximum Lineset Length Each ft(m) 8 (5) 8 (5) 8 (5) 8 (5) Minimum Lineset Length Total ft(m) 49 (5) 49 (5) 66 (0) 49 (5) Maximum Lineset Length Total ft(m) 4 (50) 4 (50) 30 (70) 64 (80) Pre-Charge Length Total ft(m) 98 (30) 98 (30) 4 (50) 4 (50) Maximum Lineset Height Difference Btwn Unit & Furthest Unit ft(m) 49 (5) 49 (5) 49 (5) 49 (5) Maximum Lineset Height Difference Btwn Units ft(m) 33 () 33 () 33 () 33 () Lineset Diameter Inch Liq. /4 x Suc. 3/8 x Liq. /4 x 3 Suc. / x, 3/8 x Liq. /4 x 4 Suc. / x, 3/8 x 3 Liq. /4 x 5 Suc. / x, 3/8 x 3 Size & Weight Net Weight lbs. (kg) 9 (54) 4 (56) 49 (68) 05 (93) Inch 7-9/ 7-9/ 3-/ 39-5/ mm 700 700 830 998 Inch 35-7/ 35-7/ 35-7/ 38-3/ mm 900 900 900 970 Inch 3 3 3 4-9/ Depth mm 330 330 330 370 Refrigerant R4A R4A R4A R4A *8+8 is the only indoor unit (ASU, ARU or AUU) combination and requires K9FZ88 See table for allowed combinations within this connectable capacity range. 55

MULTI-ZONE MINI-SPLITS 8, 4, 36,000 BTUh XLTH MULTI-ZONE OUTDOOR UNITS HIGH-HEAT AOU8RLXFZH, AOU4RLXFZH, AOU36RLXFZH AMBIENT HEATING TEMPERATURE OF Other models may go as low as, however they do not include a base heater and other advancements found in XLTH models. See the full story on page 4. Base Heater The base of Fujitsu s XLTH outdoor condensing units. When temperatures reach 36 F, a built-in heater warms the base of the outdoor unit so that condensation doesn t freeze. Without a heater, freezing condensate can cause noise, damage to the fan blade, condenser, and system performance. Base Drainage Holes The contoured base design discharges melted water through many holes located at the bottom of the unit. 8, 4,000 BTUh 36,000 BTUh IMPROVED HEATING CAPACITY Heating capacity at low outdoor temperatures was improved by adopting a large heat exchanger and a high capacity compressor. 0 % of Heating Capacity 50 Standard Series Series 47 5-5 Ambient Temperature (F ) AOU8RLXFZH AOU4RLXFZH AOU36RLXFZH Performance Connectable Units to 3 to 4 Connectable Unit Capacity Class BTUh 4,000 to,000 4,000 to 7,000 7,000 to 39,000 Rated Capacity Cooling/Heating BTUh 8,000/,000,000/5,000 35,00/36,400 Cooling Operating Range Heating Operating Range F ( C) F ( C) 4 to 5 (- to 46) -5 to 75 (-6 to 4) 4~5 (-~46) -5~75 (-6~4) 4~ 5 (-~46) -5~75 (-6~4) Electrical Rated Input Power Clg/Htg kw.33/.70.65/.8.70/.67 Voltage/Frequency/Phase 08-30/60/ 08-30/60/ 08-30/60/ Maximum Total Current Amps.4 0.8 6.0 Minimum Circuit Ampacity Amps 9.7 5. 3.5 Maximum Circuit Breaker Amps 0 30 40 Fan: Type x Quantity Propeller x Propeller x Propeller x Sound Pressure Level Cooling db(a) 48 50 53 Sound Pressure Level Heating db(a) 50 5 55 Lineset Requirements Minimum Lineset Length Each ft(m) (5) (5) (5) Maximum Lineset Length Each ft(m) 8 (5) 8 (5) 8 (5) Minimum Lineset Length Total ft(m) 49 (5) 49 (5) 49 (5) Maximum Lineset Length Total ft(m) 4 (50) 30 (70) 30 (70) Pre-Charge Length Total ft(m) 98 (30) 98 (30) 4 (50) Maximum Lineset Height Difference Btwn Unit & Furthest Unit ft(m) 49 (5) 49 (5) 49 (5) Maximum Lineset Height Difference Btwn Units ft(m) 33 () 33 () 33 () Lineset Diameter Inch Liq. /4 x Suc. 3/8 x Liq. /4 x 3 Suc. / x, 3/8 x Liq. /4 x 4 Suc. / x, 3/8 x 3 Size & Weight Net Weight lbs. (kg) 34 (6) 46 (66) 05 (93) Inch 3-/ 3-/ 39-5/ mm 830 830 998 Inch 35-7/ 35-7/ 38-3/ mm 900 900 970 Depth Inch 3 3 4-9/ mm 330 330 370 Refrigerant R4A R4A R4A NOMINAL CAPACITIES, SEER AND HSPF RATINGS Data below is based on AHRI /40 non-ducted wall mounted models. Yellow rows represent systems that are ENERGY STAR qualified. Cooling Heating Rated Heating Maximum Model Unit Capacity Capacity Capacity COP Btu/h EER SEER Btu/h Btu/h HSPF Type Combination 95F 47F 7F 7F 5F 47F Non-Ducted 9+9 8,000 3.5.5,000 4,00 3,600,000 3.79.3 AOU8RLXFZH Ducted 9+9 8,000.4 9.0,000 4,00 3,600,000 3.60 9.0 Mixed 9+9 8,000 3.0 0.3,000 4,00 3,600,000 3.70 9.7 Non-Ducted 9+7+7,000 3.3 0.0 5,000 5,400 6,400 5,000 4.04.3 AOU4RLXFZH Ducted 9+7+7,000. 8.0 5,000 5,400 6,400 5,000 3.87 9.0 Mixed 9+7+7,000.7 9.0 5,000 5,400 6,400 5,000 3.96 9.7 Non-Ducted 9+9+9+9 35,00 3.0 0.0 36,400,400 39,300 36,400 4.00.3 AOU36RLXFZH Ducted 9+9+9+9 35,00.0 8.0 36,400,400 39,300 36,400 3.88 9.3 Mixed 9+9+9+9 35,00.5 9.0 36,400,400 39,300 36,400 3.93 9.8 Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 56 57

MULTI-ZONE MINI-SPLITS FEATURES 48,000 BTUh FLEX-ZONE OUTDOOR UNIT HFI AOU48RLXFZ AOU48RLXFZ Performance A Hybrid system is the blending of a complex VRF system with the simplicity of a multi-zone system to create a hybrid solution that shares the best of both systems. Flex provides the ability to create the right combinations, the right quantity (up to 8-zones), the right style indoor units, and the right capacity. It s the right choice for your home or business. An Inverter is a system that controls the rotational speed (not just an ON/OFF signal) of an electric motor by adjusting the frequency and voltage of the electrical power supplied to the motor. The inverter constantly regulates the compressor speed to its optimum energy usage, producing higher refrigerant performance with less power consumption. This system provides individual temperature control throughout your home or business so each room, zone or floor will be the temperature you set! An optional Central Remote Controller is available which can control up to all 8 indoor units from one keypad. SELF DIAGNOSTIC FEATURE This printed circuit board provides three modes of diagnostics - setting, monitoring and function mode, as well as error codes. It also provides a pre-commissioning check function. Setting mode allows optional functions to be selected. Monitoring mode provides temperature for each thermistor, compressor operation and other functions. Function mode provides cooling test run, heating test run and pump down operation. PIPING FLEXIBILITY Contractors can choose the best direction for piping from the outdoor unit. Back COMPACT SIZE The compact size of outdoor unit AOU48RLXFZ allows for many installation opportunities. DC TWIN ROTARY COMPRESSOR A high performance, low noise, large capacity DC twin rotary compressor is used. Includes Quiet Mode for night operation. 40 minimum clearance required Connect to 8 indoor units 80 to 30% connectable capacity Connect 39,000 to 6,000 BTU Units 8k BTUh + 4 k BTUh = 4k BTUh OK k BTUh + 4 k BTUh = 36k BTUh Not Allowed (below 80%) 8 Units 7k BTUh 8 units = 56k BTU OK 9k BTUh 8 units = 7k BTU Not Allowed (over 30%) SEER HSPF EER Ducted 4.7 9.3 8.7 Non-Ducted 7.0 9.8 9.5 Mixed 5.8 9.5 8.97 Connectable Units - 8 Connectable Unit Capacity Class BTUh 80~30% Nominal (39,000~6,000) Connectable Branch Boxes - 3 Nominal Cooling BTUh 48,000 Max Cooling BTUh 5,0 Nominal Heating BTUh 54,000 Low Temp. Heating 7 F BTUh 40,000 Max Heating BTUh 57,000 Cooling Operating Range F ( C) 3~5 (-5~46) Heating Operating Range F ( C) 5~75 (-5~4) Electrical Rated Input Power Cooling* kw 5.5 / 5.9 / 5.35 Rated Input Power Heating* kw 5.0 / 4.89 / 4.96 Voltage/Frequency/Phase 08-30/60/ Maximum Current: Outdor Cooling Amps 4.5 / 3.0 / 3.7 Maximum Current: Outdor Heating Amps.3 /.7 /.0 Maximum Circuit Breaker Amps 40 Fan: Type x Quantity Propeller x Fan Motor Output W Sound Pressure Level Cooling db(a) 56 Sound Pressure Level Heating db(a) 58 Lineset Requirements Maximum Lineset Length Total ft(m) 377 (5) Max. Pipe Length Between Box & Farthest Unit ft(m) 49 (5) Max. Pipe Height Difference Between Unit & Branch Box) ft(m) 98 (30) Maximum Lineset Height Difference Btwn Unit & Furthest Unit ft(m) 98 (30) Maximum Lineset Height Difference Btwn Units ft(m) 49 (5) Lineset Diameter Inch 3/8 (Liq.) 5/8 (Suc.) Size & Weight Net Weight lbs. (kg) (98) Depth Inch 36 mm 94 Inch 38-/4 mm 970 Inch 4-5/8 mm 370 Refrigerant R4A Front Bottom Right Applies when properly registered AND installed by a Fujitsu Elite Contractor in a residence. See full warranty for details. 37*Ducted / Non-Ducted / Mixed 58 59

MULTI-ZONE MINI-SPLITS BRANCH BOXES UTP-PU03A, UTP-PU03B By reversing the electrical box position you can orient the inlet and outlet pipes into a left hand or right hand configuration. UTP-PU03A Primary UTP-PU03B Secondary Connectable Unit ~ 3 ~ 3 Max. Combination BTUh 6,000 Nom.* 6,000 Nom.* Min. Combination BTUh 7,000 Nom.* 7,000 Nom.* Clg. Operating Range F( C) 5-5 (-5-46) 5-5 (-5-46) Htg. Operating Range F( C) 5-75 (-5-4) 5-75 (-5-4) %RH 80 or less 80 or less Voltage/Frequency/Phase 08-30/60/ 08-30/60/ Maximum Current Ampacity (A) 5 5 Running Current Rated (A): Cooling 0.050 0.050 Heating 0.050 0.050 Power Use Rated (W): Cooling Heating *As long as the total system nominal capacity is between 39,000 and 6,000 BTUh. By reversing the electrical box position you can orient the inlet and outlet pipes into a left hand or right hand configuration. UTP-PU03A Primary UTP-PU03B Secondary Dimensions: Gross (Flare to Flare): Height x x Depth Inch 7-5/8 x 33 x 4-5/8 7-5/8 x 33 x 4-5/8 Height x x Depth mm 95 x 838 x 370 95 x 838 x 370 Dimensions: Net (Metal Box Only): Height x x Depth Inch 7-5/8 x 7 x 4-5/8 7-5/8 x 7 x 4-5/8 Height x x Depth mm 95 x 433 x 370 95 x 433 x 370 Net Weight lbs. (kg) 0 (9) 0 (9) Conn. Pipe Diameter - Main Inch (3/8 Liq. x 5/8 Suc.) (3/8 Liq. x 5/8 Suc.) Conn. Pipe Diameter - Branch Inch (/4 Liq. x / Suc.) 3 pair Connection Method Flare Flare Connection Adapter Included Inch (/MF x 3/8FF) x 3 (/MF x 5/8FF) x 3 No adapter needed for 8k BTU Warning: Branch boxes are not weather tight enclosures and cannot be mounted outdoors or in damp environments exceeding 80% relative humidity, unless using the Branch Box Enclosure, Part #UTP-PX-A. ALLOWED BRANCH BOX MOUNTING DIRECTION BRANCH BOX OUTDOOR ENCLOSURE UTP-PX-A SEPARATION TUBE ASSEMBLY KIT UTP-SX48A Size Threaded Rod Mount Horizontal Wall Mount Vertical Wall Mount Liquid Inch 3/8 x 3/8 x 3/8 Suction Inch 5/8 x 5/8 x 5/8 (/4 Liq. x / Suc.) 3 pair (/MF x 3/8FF) x 3 (/MF x 5/8FF) x 3 No adapter needed for 8k BTU You cannot reverse the electrical box position when mounting the branch box vertically. The Branch Box Enclosure is used to mount the indoor style Branch Box outdoors. The Branch Box Enclosure is a painted metal cover to match the condensing unit. When Branch Box Enclosure is not required, see Installation Manual for indoor mounting instructions. Allowed Mounting Positions Dimensions in. (mm) Net (HxWxD) Gross (HxWxD) Weight lbs. (kg) 8-/ x 3 x 7-7/8 (0 x 83 x 454) 3-5/ x 33-/ x 0-5/ (0 x 880 x 55) Net Branch Box cover only () Net Branch Box + Cover 44.(0) Gross 30.9 (4) PIPING Separation Tube Assembly Kit Liquid pipe 3/8 inch Gas pipe 5/8 inch Liquid pipe /4 inch Gas pipe 3/8, /, or 5/8 based on indoor unit size* Flare connections Branch Box to Calculate Refrigerant Charge Factory Charge 7.6 lb (3.45 kg) Unit pre-charged to 0 feet Total Pipe Length 377 max. ** a Height difference between outdoor and indoor units 98 max. * Distance between outdoor unit & farthest indoor unit. ** Total liquid pipe or total gas pipe. b f g h *Branch box outlets are all / on gas pipe connections. / to 3/8 adaptors and / to 5/8 adaptors included (3 of each). e c i j k l m Liquid pipe Adaptor Gas pipe 7,000 BTUh included 9,000 BTUh included 3/8,000 BTUh /4 included 8,000 BTUh n/a / 4,000 BTUh included 5/8 Pipe Diameter Location Additional Refrig. 3/8 to Branch Box 0.64 oz./ft. or 58g/meter /4 Branch Box to Unit 0.4 oz./ft. or g/meter (Total length of 3/8 liquid line 0.64 oz./ft. or 58g/meter ) + (Total length of /4 liquid line 0.4 oz./ft. or g/meter ) (a+b+c+d+e) 0.64 oz./ft. or 58g/meter + (f+g+h+i+j+k+l+m) 0.4 oz./ft. or g/meter = additional refrigerant min. Piping length between outdoor unit and farthest branch box 80 max. Branch Box min. Branch Box Pipe length between branch box and indoor unit min. 49 max. Actual pipe length 30 max. * 7 min. Height difference between branch boxes 49 max. Height difference between indoor and indoor units 49 max. 60 6

MULTI-ZONE MINI-SPLITS SLIM DUCT BRANCH BOXES CASSETTE WALL MOUNT SEPARATION TUBES AOU48RLXFZ WHOLE HOME SOLUTIONS flex 48,000 BTUh FLOOR MOUNT Connect to 8 indoor units 80 to 30% connectable capacity Connect 39,000 to 6,000 BTU Branch boxes and separation tubes required Cool or heat one room, a few rooms or an entire home. 6 63

MULTI-ZONE MINI-SPLITS ALLOWABLE COMBINATIONS Select either an 8, 4, 36, 45 or 48,000 BTUh outdoor unit combined with wall mounted, slim duct, compact cassette or floor mount type indoor units. Mix-and-match flexibility of evaporator type and capacity allows you to choose the indoor unit that best fits the application, whether it be hidden or showcased. ALLOWABLE COMBINATIONS CONT D. CHOOSE INDOOR UNITS: CHOOSE AN OUTDOOR UNIT: AOU8RLXFZ AOU4RLXFZ AOU8RLXFZH AOU4RLXFZH AOU36RLXFZ AOU36RLXFZH AOU45RLXFZ AOU48RLXFZ ASU7RLF ASU9RLF ASURLF ASU5RLF ASU8RLF ASU4RLF ARU7RLF ARU9RLF ARURLF ARU8RLF ARU4RLF AUU7RLF AUU9RLF AUURLF AUU8RLF AGU9RLF AGURLF AGU5RLF BTUh Capacity 7,000 9,000,000 5,000 8,000 4,000 = Allowed Connectable Capacity combinations between 0 and 30% INDOOR UNITS 3 INDOOR UNITS MAX INDOOR UNITS 4 INDOOR UNITS MAX AOU8RLXFZ / AOU8RLXFZH 7 7 4 7 9 7 9 9 9 8 9 AOU4RLXFZ / AOU4RLXFZH 7 7-4 7 9-7 - 9 7 5 7 8 5 9 9-8 9 9 5 4 9 8 7 4 5 7 7 7 7 7 7 9 3 7 7 6 7 9 9 5 9 9 9 7 AOU36RLXFZH 8 8 36 7 4 3 9 4 33 4 36 5 4 39 AOU36RLXFZ / AOU36RLXFZH 8* 8* 36 7 7 5-9 7 7 8-3 7 7 4 38 7 9-8 7 9 5-3 7 9 8 34 7-3 7 5 34 7 8 37 9 9 9-7 4 INDOOR UNITS MAX INDOOR UNITS 3 INDOOR UNITS MAX 9 9-30 9 9 5 33 9 9 8 36 9 33 9 5 36 9 8 39 36 5 39 7 7 7 7 8 7 7 7 9 30 7 7 7 33 7 7 7 5 36 7 7 7 8^ 39 7 7 9 9 3 7 7 9 35 7 7 9 5 38 7 7 38 7 9 9 9 34 7 9 9 37 9 9 9 9 36 9 9 9 39 AOU45RLXFZ 8 8 36 4 36 5 4 39 8 4 4 4 4 48 7 7 4 38 7 9 8 34 7 9 4 40 7 8 37 7 4 43 7 5 5 37 7 5 8 40 7 5 4 46 7 8 8 43 7 8 4 49 9 9 8 36 9 9 4 4 9 5 36 9 8 39 Actual rated cooling capacity of ASU5RLF is 4,000 BTU/h. * The optional kit K9FZ88 (UTP-MU36A) is necessary for dual zone system 8+8 with AOU36RLXFZ only. ^ Wall mounted type ASU8RLF cannot be connected in this combination. - represents available circuit for future expansion when connecting this combination. 3 INDOOR UNITS MAX 4 INDOOR UNITS MAX 9 4 45 9 5 5 39 9 5 8 4 9 5 4 48 9 8 8 45 9 8 4 5 36 5 39 8 4 5 5 4 5 8 45 5 4 5 8 8 48 8 4 54 5 5 5 45 5 5 8 48 5 5 4 54 5 8 8 5 8 8 8 54 7 7 7 5 36 7 7 7 8 39 7 7 7 4 45 7 7 9 35 7 7 9 5 38 7 7 9 8 4 7 7 9 4 47 7 7 38 7 7 5 4 7 7 8 44 7 7 4 50 7 7 5 5 44 7 7 5 8 47 7 7 5 4 53 7 7 8 8 50 7 9 9 9 34 7 9 9 37 7 9 9 5 40 7 9 9 8 43 7 9 9 4 49 7 9 40 7 9 5 43 4 INDOOR UNITS MAX 5 INDOOR UNITS MAX 7 9 8 46 7 9 4 5 7 9 5 5 46 7 9 5 8 49 7 9 8 8 5 7 43 7 5 46 7 8 49 7 5 5 49 7 5 8 5 7 5 5 5 5 9 9 9 9 36 9 9 9 39 9 9 9 5 4 9 9 9 8 45 9 9 9 4 5 9 9 4 9 9 5 45 9 9 8 48 9 9 4 54 9 9 5 5 48 9 9 5 8 5 9 9 8 8 54 9 45 9 5 48 9 8 5 9 5 5 5 9 5 8 54 48 5 5 8 54 5 5 54 7 7 7 7 7 35 7 7 7 7 9 37 7 7 7 7 40 7 7 7 7 5 43 7 7 7 7 8 46 7 7 7 7 4 5 7 7 7 9 9 39 7 7 7 9 4 7 7 7 9 5 45 5 INDOOR UNITS MAX 7 7 7 9 8 48 7 7 7 9 4 54 7 7 7 45 7 7 7 5 48 7 7 7 8 5 7 7 7 5 5 5 7 7 7 5 8 54 7 7 9 9 9 4 7 7 9 9 44 7 7 9 9 5 47 7 7 9 9 8 50 7 7 9 47 7 7 9 5 50 7 7 9 8 53 7 7 9 5 5 53 7 7 50 7 7 5 53 7 9 9 9 9 43 7 9 9 9 46 7 9 9 9 5 49 7 9 9 9 8 5 7 9 9 49 7 9 9 5 5 7 9 5 9 9 9 9 9 45 9 9 9 9 48 9 9 9 9 5 5 9 9 9 9 8 54 9 9 9 5 9 9 9 5 54 9 9 54 INDOOR 3 INDOOR UNITS MAX 4 INDOOR UNITS MAX AOU48RLXFZ 8 4 4 4 4 48 7 9 4 40 7 4 43 7 5 8 40 7 5 4 46 7 8 8 43 7 8 4 49 7 4 4 55 9 9 4 4 9 8 39 9 4 45 9 5 8 4 9 5 4 48 9 8 8 45 9 8 4 5 9 4 4 57 8 4 4 48 5 5 4 5 8 45 5 4 5 8 8 48 8 4 54 4 4 60 5 5 5 45 5 5 8 48 5 5 4 54 5 8 8 5 5 8 4 57 5 4 4 63 8 8 8 54 8 8 4 60 7 7 7 8 39 7 7 7 4 45 7 7 9 8 4 7 7 9 4 47 7 7 5 4 7 7 8 44 7 7 4 50 7 7 5 5 44 7 7 5 8 47 7 7 5 4 53 4 INDOOR UNITS MAX 7 7 8 8 50 7 7 8 4 56 7 7 4 4 6 7 9 9 5 40 7 9 9 8 43 7 9 9 4 49 7 9 40 7 9 5 43 7 9 8 46 7 9 4 5 7 9 5 5 46 7 9 5 8 49 7 9 5 4 55 7 9 8 8 5 7 9 8 4 58 7 43 7 5 46 7 8 49 7 4 55 7 5 5 49 7 5 8 5 7 5 4 58 7 8 8 55 7 8 4 6 7 5 5 5 5 7 5 5 8 55 7 5 5 4 6 7 5 8 8 58 7 8 8 8 6 9 9 9 39 9 9 9 5 4 9 9 9 8 45 9 9 9 4 5 9 9 4 9 9 5 45 9 9 8 48 9 9 4 54 9 9 5 5 48 9 9 5 8 5 9 9 5 4 57 9 9 8 8 54 9 9 8 4 60 9 45 9 5 48 4 INDOOR UNITS MAX 5 INDOOR UNITS MAX 9 8 5 9 4 57 9 5 5 5 9 5 8 54 9 5 4 60 9 8 8 57 9 5 5 5 54 9 5 5 8 57 9 5 5 4 63 9 5 8 8 60 48 5 5 8 54 4 60 5 5 54 5 8 57 5 4 63 8 8 60 5 5 5 57 5 5 8 60 5 8 8 63 5 5 5 5 60 5 5 5 8 63 7 7 7 7 40 7 7 7 7 5 43 7 7 7 7 8 46 7 7 7 7 4 5 7 7 7 9 9 39 7 7 7 9 4 7 7 7 9 5 45 7 7 7 9 8 48 7 7 7 9 4 54 7 7 7 45 7 7 7 5 48 7 7 7 8 5 7 7 7 4 57 7 7 7 5 5 5 7 7 7 5 8 54 7 7 7 5 4 60 7 7 7 8 8 57 7 7 9 9 9 4 7 7 9 9 44 7 7 9 9 5 47 7 7 9 9 8 50 64 65

FEATURES MULTI-ZONE MINI-SPLITS ACCESSORIES ALLOWABLE COMBINATIONS CONT D BTUh Capacity 7,000 9,000,000 5,000 8,000 4,000 5 INDOOR UNITS MAX = Allowed Connectable Capacity combinations between 0 and 30% AOU48RLXFZ, con't. 7 7 9 9 4 56 7 7 9 47 7 7 9 5 50 7 7 9 8 53 7 7 9 4 59 7 7 9 5 5 53 7 7 9 5 8 56 7 7 9 5 4 6 7 7 9 8 8 59 7 7 50 7 7 5 53 7 7 8 56 7 7 4 6 7 7 5 5 56 7 7 5 8 59 7 7 8 8 6 7 7 5 5 5 59 7 7 5 5 8 6 7 9 9 9 9 43 7 9 9 9 46 7 9 9 9 5 49 7 9 9 9 8 5 7 9 9 9 4 58 7 9 9 49 7 9 9 5 5 7 9 9 8 55 7 9 9 4 6 7 9 9 5 5 55 7 9 9 5 8 58 7 9 9 8 8 6 7 9 5 7 9 5 55 7 9 8 58 7 9 5 5 58 7 9 5 8 6 7 9 5 5 5 6 7 9 5 5 8 64 5 INDOOR UNITS MAX 6 INDOOR UNITS MAX 7 55 7 5 58 7 8 6 7 5 5 6 7 5 5 5 64 9 9 9 9 9 45 9 9 9 9 48 9 9 9 9 5 5 9 9 9 9 8 54 9 9 9 9 4 60 9 9 9 5 9 9 9 5 54 9 9 9 8 57 9 9 9 5 5 57 9 9 9 5 8 60 9 9 54 9 9 5 57 9 9 8 60 9 9 5 5 60 9 9 5 8 63 9 9 5 5 5 63 9 57 9 5 60 9 5 5 63 60 5 63 7 7 7 7 7 7 4 7 7 7 7 7 9 44 7 7 7 7 7 47 7 7 7 7 7 5 50 7 7 7 7 7 8 53 7 7 7 7 7 4 59 7 7 7 7 9 9 46 7 7 7 7 9 49 7 7 7 7 9 5 5 7 7 7 7 9 8 55 7 7 7 7 9 4 6 6 INDOOR UNITS MAX 7 7 7 7 5 7 7 7 7 5 55 7 7 7 7 8 58 7 7 7 7 5 5 58 7 7 7 7 5 8 6 7 7 7 9 9 9 48 7 7 7 9 9 5 7 7 7 9 9 5 54 7 7 7 9 9 8 57 7 7 7 9 54 7 7 7 9 5 57 7 7 7 9 8 60 7 7 7 9 5 5 60 7 7 7 9 5 8 63 7 7 7 57 7 7 7 5 60 7 7 7 5 5 63 7 7 9 9 9 9 50 7 7 9 9 9 53 7 7 9 9 9 5 56 7 7 9 9 9 8 59 7 7 9 9 56 7 7 9 9 5 59 7 7 9 9 8 6 7 7 9 9 5 5 6 7 7 9 59 7 7 9 5 6 7 7 6 7 9 9 9 9 9 5 7 9 9 9 9 55 7 9 9 9 9 5 58 7 9 9 9 9 8 6 7 9 9 9 58 7 9 9 9 5 6 7 9 9 6 6 INDOOR UNITS MAX 7 INDOOR UNITS MAX 8 INDOOR UNITS MAX 9 9 9 9 9 9 54 9 9 9 9 9 57 9 9 9 9 9 5 60 9 9 9 9 60 9 9 9 9 5 63 7 7 7 7 7 7 7 49 7 7 7 7 7 7 9 5 7 7 7 7 7 7 54 7 7 7 7 7 7 5 57 7 7 7 7 7 7 8 60 7 7 7 7 7 9 9 53 7 7 7 7 7 9 56 7 7 7 7 7 9 5 59 7 7 7 7 7 9 8 6 7 7 7 7 7 59 7 7 7 7 7 5 6 7 7 7 7 9 9 9 55 7 7 7 7 9 9 58 7 7 7 7 9 9 5 6 7 7 7 7 9 6 7 7 7 9 9 9 9 57 7 7 7 9 9 9 60 7 7 7 9 9 9 5 63 7 7 9 9 9 9 9 59 7 7 9 9 9 9 6 7 9 9 9 9 9 9 6 7 7 7 7 7 7 7 7 56 7 7 7 7 7 7 7 9 58 7 7 7 7 7 7 7 6 7 7 7 7 7 7 9 9 60 7 7 7 7 7 9 9 9 6 Remote Sensor UTY-XSZX Wall mounted room temperature sensor for slim duct models. Replaces room temperature sensor in the return when installed while still allowing for temperature correction. Wireless Remote Control UTY-LNHUM For spaces where there is just no place to mount the wired remote or where wireless operation is preferred. Wired Remote Control UTY-RVNUM Group 3-Wire Control Features a large backlit LCD display and displays the room temperature. Provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. Simple Remote Control Group -Wire Control UTY-RSRY Backlit -wire remote with built in temperature sensor. Offers set point (Compatible with System 30RLXEH) Central Controller UTY-DMMUM 3-Wire This remote controls up to 8 individual indoor units. Set temperatures on timers to best meet individuals needs. Includes a large backlit LCD and 4-way navigation pad. Remote connects in daisy chain to branch boxes. Simple Remote Control UTY-RSNUM Group 3-Wire Control Suitable when only basic operations are required for hotels, offices and other places where there is frequent arrival and departure of occupants. Remote does not allow any timer settings. Wired Remote (Touch Panel) UTY-RNRUZ -Wire Features a large backlit LCD display and displays the room temperature. Provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. (Compatible with System 30RLXEH) Receiver Unit UTY-LRHUM 3-Wire For slim duct models. Includes a wireless remote control. Group Control: With this feature, multiple evaporators can be daisy-chained together on one single remote control, allowing for multiple single-zoned systems installed in an application to be grouped together by evaporator. The same feature can be used on a multi-zone system however, multiple multi-zone systems cannot be grouped together nor can a single-zone system be group controlled with a multi-zone system. For additional information, see Engineering Bulletin # 036 and/or 037. ^ Minimum Heat, Sleep Timer functions will be lost when the wired remote control is installed. * Wall mounted ASU7, 9, and RLF require accessory interface kit (Part UTY-XCBXZ) in order to connect this device to them. Wall mounted ASU9,, and 5RLS3/H require accessory interface kit (Part UTY-TWBXF) in order to connect this device to them. NOT compatible with models ABU8/4RULX, ABU36RSLX, AUU8/4/36/4RCLX. 66 67 CONTROLS Wired Remote Control UTY-RNNUM Group UTY-RNBYU Control 3-Wire The wired remote control with its unique lock function and sleek design provides full feature access to property managers, building owners, and facility maintenance, as well as providing basic comfort features to tenants, employees, and teachers. WI-FI DEVICES See compatability table, page 3. IR Wireless Module Model: FJ-IR-WIFI-NA Works with IntesisHome app Wired Module Model: FJ-RC-WIFI-NA Works with IntesisHome app ADDITIONAL CONTROLS Network Converter UTY-VTGX The Network Converter is used to control and monitor one or more single-zone Halcyon indoor units (max of IDU s per converter) through Airstage VRF Central Controllers. SAMPLE WI-FI APP SCREEN DISPLAYS IntesisHome FGLAir Wi-Fi Module Model: UTY-TFNXZ Works with FGLair app Group Control Thermostat Converter UTY-TTRX Control Halcyon products using a third party thermostat. Up to indoor units can be connected as a group to one thermostat convertor.

FEATURES ACCESSORIES INTERFACE KITS Dry Contact Wire Kit * UTY-XWZX/UTY-XWZXZ5 Interface Kit UTY-XCBXZ Interface Kit UTY-TWBXF ACCESSORY COMPATIBILITY WALL MOUNTED SINGLE-ZONE FLOOR MOUNT COMPACT CASSETTE SLIM DUCT UNIVERSAL FLOOR / CEILING LARGE CASSETTE HFI MULTI-ZONE AND FLEX-ZONE Turns system on or off using a normally open circuit. For example in home automation, BMS integration of only On/Off operation, occupancy sensor, key card switch, or lead-lag control of other heating/cooling devices. Slim Duct Connector Kit UTD-ECS5A Comes with 5 sets of wires. Can be used to turn unit on/off, wire in float switch, AUX heater, turn on an external device (Fan), or show if the unit is running. Interface Kit UTY-XCSXZ Required to connect ASU30RLE to Dry Contact Wire Kit UTY-XWZX3, and Lead Lag Control function^. FRESH AIR INTAKE KITS High Humidity Insulation Kit UTZ-KXGC Additional insulation for compact cassette units, which may be needed when they are installed in high humidity areas. MISCELLANEOUS 3-Pole Single Throw Safety Switch K3PST For use where code requires a disconnect at the indoor unit. Condensate Pump UTR-DPB4T OEM design plugs into factory harness for ease of installation. Rated for.8 of vertical lift. Only used with System 36RSLX. Air Outlet Shutter Plate UTR-YDZB Required to connect ASU7RLF, 9RLF, and RLF to Wired Remotes UTY-RNNUM and UTY-RVNUM, Dry Contact Wire Kit UTY-XWZX, and Simple Remote Control UTY-RSNUM. Unit Input/Output Connector UTY-XWZXZ3 In a 3-way air flow configuration an Air Outlet Shutter Plate kit is required to block air flow of louver. Gives the ability to limit the noise of the unit*, stop the outdoor unit, limit power consumption*, control the operating mode (Htg/Clg), or use output status to see if the compressor is running. You will need to order a kit for each option. Interface Kit Box UTZ-GXXB Used to conceal Interface Kit UTY-XCSXZ. Fresh Air Intake Kit UTZ-VXAA 8+8 Combo Fittings Kit K9FZ88 Mixes room air then passes it through a heat exchanger. Allows for a 4-inch flex duct connection. Requires a field supplied duct booster fan capable of 60 CFM at. W.C. or 90 CFM at.4 W.C. For fan static pressure requirements, see installation manual. R4A Swivel Adapter K9R4A55 In order to minimize incorrect charging of systems with R Fujitsu uses a different access port. Contractors will need this 55-degree swivel access fitting. Allows two 8,000 BTU indoor units to be used on an outdoor AOU36RLXFZ. Requires special piping; limited to only 8,000 BTU models. Total BTU capacity is limited to 3,600 BTU in cooling. The kit upsizes linesets to 3/8 and /. Required to connect the ASU5RLS/H + and ASU9,, 5RLS3/H to Wired Remotes UTY-RNNUM and UTY-RVNUM, Dry Contact Wire Kit UTY-XWZXZ5, and Simple Remote Control UTY-RSNUM. Unit Base Heater Connector UTY-XWZXZ4 Used to hook up an AUX base pan heater to the outdoor unit. Heater will stop ice from forming in the outdoor unit. Base heater will operate when outdoor temperature is below 36 F. Heater is field supply. Heaters greater than 5W can t be fed directly from the board, but have to be powered from another source. * Will reduce capacity. ^ Wired remotes cannot be used when using this feature. This includes UTY-RNRUZ, UTY- RVNUM, UTY-RNNUM, UTY-RSNUM. Fresh Air Intake Kit KHRS940-5 Fresh air kit for RCLX/RULX/RSLX systems. Kit contains Current Sensor with Built-in Relay and Switching Power Supply. Requires field supplied ductwork and a fan capable of generating 5 CFM at a static pressure of approximately 0.6 WC. Plug Model UTY-WIFI In order to connect certain models to Wired Wi-Fi Module, FJ-RC-WIFI-NA, this plug must be used. Auto Louver Grille Kit UTD-GXSA-W (for ARU7/9/) UTD-GXSB-W (for ARU8) UTD-GXSC-W (for ARU4) Auto Louver provides comfortable airflow and blends in with various interiors. Grille can be connected either directly to indoor unit or through the rectangular duct. Only compatible with ARU models with serial numbers greater than 000. 9RL 9RLFW 9RLS3Y 9RLS3YH RL RLFW RLS3Y RLS3YH 5RLS3Y 5RLS3YH 8RLB 8RLXFW 8RLXFWH 4RLB 4RLXFW 4RLXFWH 30RLXB 30RLXEH 36RLXB 9RLFF RLFF 5RLFF 9RLFFH RLFFH 5RLFFH 9RLFCC RLFCC 8RLFCC 9RLFCD RLFCD 8RLFCD 8RULX 4RULX 36RSLX 8RCLX 4RCLX 36RCLX 4RCLX Small Wall (RLF - 7, 9,, 5k BTU) Large Wall (8, 4k BTU) Cassette Slim Duct Floor Mount AOU45RLXFZ AOU48RLXFZ REMOTE CONTROLS UTY-RNBYU Wired Remote Control UTY-RNNUM Wired Remote Control 3 3 3 Wired Remote Control UTY-RVNUM (Backlit) 3 3 3 4 4 4 4 UTY-RSNUM Simple Remote Control 3-Wire 3 3 3 UTY-RSKU Simple Remote Control -Wire UTY-LNHUM Wireless Remote Control UTY-DMMUM Central Remote Control UTY-RNRUZ Wired Remote Control UTY-XSZX Remote Sensor UTY-LRHUM Receiver Unit WI-FI DEVICES FJ-IR-WIFI-NA Wi-Fi Device: IR Wireless Module 6 6 6 FJ-RC-WIFI-NA Wi-Fi Device: Wired Module * * 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 * UTY-TFNXZ Wi-Fi Module UTY-WIFI Wi-Fi Plug 5 INTERFACE KITS UTY-XWZX Dry Contact Wire Kit UTY-XWZXZ5 Dry Contact Wire Kit 3 UTY-XCBXZ Interface Kit 3 UTY-TWBXF Interface Kit UTD-ECS5A Slim Duct Connector Kit Unit UTY-XWZXZ3 Input/Output Connector Unit Base UTY-XWZXZ4 Heater Connector UTY-XCSXZ Interface Kit UTZ-GXXB Interface Kit Box FRESH AIR INTAKE KITS UTZ-KXGC High Humidity Insulation Kit UTR-YDZB Air Outlet Shutter Plate UTZ-VXAA Fresh Air Intake Kit KHRS940-5 Fresh Air Intake MISCELLANEOUS UTY-TTRX Thermostat Converter UTY-VTGX Network Converter K3PST 3-Pole Single Throw Safety Switch K9R4A55 R4A Swivel Adapter UTR-DPB4T Condensate Pump K9FZ88 8+8 Combo Fittings Kit (for AOU36RLXFZ) Auto Louver Grille Kit UTD-GXSA-W (for ARU9, ) UTD-GXSB-W Auto Louver Grille Kit (for ARU8) Auto Louver Grille Kit UTD-GXSC-W (for ARU4) If using UTY-RNBYU with these models you need to change the dip switch SW- to ON. Refer to Tech Tip #08. Wall mounted ASU9,, and 5RLS3Y/RLS3YH require accessory interface kit #UTY-TWBXF in order to connect these devices to them. 3 Wall mounted ASU7, 9, and RLF require accessory interface kit #UTY-XCBXZ in order to connect these devices to them.tt4 Only multi-zone models greater than specific serial numbers are compatible with UTY-RV- NUM. See Service Bulletin 003 for serial number compatibility.t 5 Plug model #UTY-WIFI required to connect these devices to them. 6 Wireless Receiver #UTY-LRHUM is required in order to connect this device. * Requires accessory interface kit #UTY-XCBXZ and plug model #UTY-WIFI in order to connect these devices to them. ^ Requires accessory interface kit #UTY-TWBXF and plug model #UTY-WIFI in order to connect these devices to them. 68 69

MISCELLANEOUS LINE SET SIZES AND LENGTHS SINGLE-ZONE SYSTEMS 9RL 9RLFF 9RLFFH 9RLFW 9RLS3 9RLS3H RL RLFF RLFFH RLFW RLS3 RLS3H 5RLFF 5RLFFH 5RLS3 5RLS3H 8RLB 8RLXFW 8RLXFWH 4RLXFW 4RLXFWH 4RLB 30RLXEH 30RLXB 36RLXB 9RLFCD RLFCD 8RLFCD 9RLFCC RLFCC 8RLFCC 8RULX 4RULX 36RSLX 8RCLX 4RCLX 36RCLX 4RCLX /4 x 3/8 /4 x / /4 x 5/8 3/8 x / 3/8 x 5/8 Total System Max. Combined 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 66 5 5 5 5 66 46 5 5 66 66 66 66 66 66 5 5 5 5 5 5 30 Pipe Length ft (m) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0) (0)(50)(50)(50)(50)(0)(75)(50)(50)(0)(0)(0)(0)(0)(0)(50)(50)(50)(50)(50)(50)(70) Min. Combined Pipe Length ft (m) While these systems share indoor units, different line sizes are required. (5) (5) (5) (5) MULTI / FLEX ZONE MODELS ASU7RLF ASU9RLF ASURLF ASU8RLF ASU4RLF AGU9RLF AGURLF AGU5RLF ARU7RLF ARU9RLF ARURLF ARU8RLF ARU4RLF AUU7RLF AUU9RLF AUURLF AUU8RLF ASU8RLF x * AGU8RLF x * ARU8RLF x * AUU8RLF x * UTP-PU03A /B^ /4 x 3/8 /4 x / /4 x 5/8 3/8 x / 3/8 x 5/8 Total System Max. Combined Pipe Length ft (m) 5 5 5 5 30 3 30 64 (50) (50) (50) (50) (70) (40) (70) (80) 377 (5) Min. Combined 49 49 49 49 66 49 49 49 Pipe Length ft (m) (5) (5) (5) (5) (0) (5) (5) (5) (5) Each Unit Minimum and maximum pipe lengths for multi-zone units are found on pages 55, 57 and 60. *8+8 is the only indoor unit combination allowed for AOU36RLXFZ and requires kit K9FZ88. While these systems share indoor units, different line sizes are required. ^ Line set size from outdoor unit AOU48RLXFZ to the branch boxes. Minimum combined pipe length from outdoor unit to branch box. Minimum combined pipe length from branch box to indoor unit each. (5) (5) (5) AOU8RLXFZ AOU8RLXFZH AOU4RLXFZ AOU4RLXFZH AOU36RLXFZ (5) (5) AOU36RLXFZ (8+8) (5) AOU36RLXFZH (5) AOU45RLXFZ (5) (5) AOU48RLXFZ (5) THINGS TO KNOW BEFORE YOU BUY A FUJITSU SYSTEM COMPLETE SYSTEM WARRANTY TRADEMARKS Standard warranties vary depending on model: WARNING 6 Year Compressor / Year Parts warranty OR 7 Year Compressor / 5 Year Parts warranty. Extended warranties include: Year Compressor/Parts warranty for Halcyon systems that have been installed by a licensed contractor and the online Product Registration* has been submitted. Year Compressor/Parts warranty for Halcyon systems that have been installed by an Elite Contractor and the online Product Registration* has been submitted. -Year and -Year warranties exclude: R models, IAQ models, ASU30RLX, ABU8RULX, ABU4RULX, ABU36RSLX, AUU8RLCX, AUU4RCLX, AUU36RCLX, AUU4RCLX, AOU8RLX, AOU4RLX, AOU30RLX, AOU36RLX, AOU4RLX * Residents of California and Quebec are not required to register the System in order to obtain all of the rights and remedies applicable to this Warranty. For full details, see Halcyon Warranty Statement. Always use a licensed installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only parts and accessories supplied or specified by Fujitsu. Ask a licensed contractor to install parts and accessories. Use of unauthorized or improper installation of parts and accessories can result in injury or property damage. Read the owner s operation manual carefully before using this product. The owners operation manual provides important safety instructions and warnings which should be followed closely. For any questions or concerns, please contact Fujitsu General America, Inc. Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov. The Fujitsu logo is a registered trademark of Fujitsu Limited. The Halcyon and Halcyon HFI logos and names are trademarks of Fujitsu General America, Inc. ENERGY STAR is a registered trademark of the EPA and DOE. Copyright 07 Fujitsu General America, Inc. NON-INTERNET RETAIL POLICY Internet sales are strictly prohibited and unauthorized. Any HVAC systems purchased on the Internet, from an online retailer or any similar e-tailing website, OR where the original factory serial numbers of the display have been removed, defaced, or replaced in any way WILL NOT BE COVERED BY WARRANTY. Note: Condensing units come pre-charged from factory. Additional refrigerant may be required, be sure to check installation manual for more details. NOTE THINGS TO KNOW BEFORE YOU INSTALL A FUJITSU SYSTEM Cooling capacity is based on the following conditions: temperature: 80 F DB/67 F WB (6.7 C DB/9.4 C WB) temperature: 95 F DB/75 F WB (35 C DB/3.9 C WB) Heating capacity is based on the following conditions: temperature: 70 F DB (. C DB) temperature: 47 F DB/43 F WB (8.3 C DB/6. C WB) HEAT PUMP DISCLAIMER In most climates a heat pump will handle all of your heating needs. However, this system sometimes requires some other additional source of heat to satisfy heating requirements in the coldest environments. Almost all of Fujitsu s heat pumps use inverter technology and as such offer a wider operating range and more heat capacity than a standard heat pump but will not provide adequate heating if improperly sized or operated outside of its operating range. Specifications vary by model; please consult your contractor before choosing a heat pump as your only source of heat. Systems will maintain temperature up to +/-4 degrees relative to set temperature. To increase energy efficiency on multi-type systems, you should turn off the evaporators when heating or cooling is not needed. DISCLAIMER Fujitsu s products are subject to continuous improvements. Fujitsu reserves the right to modify product design, specifications and information in this brochure without notice and without incurring any obligations. FUJITSU MODEL NOMENCLATURE Model 8 R L X F Z H ASU Wall Mount ABU Universal Mount Ceiling Susp. BTUh in thousands R = Reverse cycle heat pump C = Cooling only S = C = Cassette L = Inverter S = Ceiling Susp. ARU Slim Duct L = Inverter S = X = Extended Line Set Super Efficient AUU Cassette Mount U = Universal F = HFI H = AGU Floor Mount B = 30V W = AOU Unit C = X = F = B = Super Efficient Extended Line Set followed by HFI (when a W or Z ) or Floor Mount High Heating Wall Mount Only Compact Cassette or Slim Duct 30V Z= Zone H = W= H = Wall Mount Only High Heating High Heating CERTIFICATIONS ISO ISO400 is the standard defined by the International Organization for Standardization (ISO) related to environmental management systems. Fujitsu General America, Inc. has been acknowledged by an internationally accredited compliance organization as having an appropriate program of environmental protection procedures and activities to meet the requirements of ISO400. The air conditioners manufactured by Fujitsu have received ISO900 series certification for quality assurance. AHRI ENERGY GUIDE PROGRAM (U.S.) ISO900 ISO400 To view AHRI numbers or Energy Guide labels, please go to www.ahridirectory.org. ASTM Our outdoor units shall withstand,000 hours of salt spray tested per procedure ASTM B7. ROHS COMPLIANT Fujitsu participates in the RoHS Directive, which is the Restriction of Hazardous Substances in electrical and electronic equipment. It is an EU directive intended protect the environment by forcing manufacturers to eliminate or severely curtail the use of cadmium, hexavalent chromium, and lead in all products from automobiles to consumer electronics. HRAI ENERGUIDE PROGRAM (CANADA) Samples: E = Engineering Series 4.0-33.0 *, or 3 at the end of a model number denotes a model revision. Please note models may not be combined with each other. 70 7

FEATURES For over 40 years, making the hottest places cool and the coolest places... more comfortable. Halcyon Mini-Splits Are For You If: If you want to reduce your utility bills by up to 5% Central air quotes give you sticker shock You don t want to lose space to ductwork You have warm or cold spots in your home or business Your window air conditioner s noise prevents you from hearing the television Distributed by: is worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark of Japan, the USA, and other countries or areas. is worldwide trademark of FUJITSU GENERAL LIMITED. Part #6-6-FG08 Rev. /8 Fujitsu General America, Inc. 353 Route 46 West Fairfield, NJ 07004 Toll Free: (888) 888-344 Local: (973) 575-0380 Fax: (973) 836-0447 Email: hvac@fujitsugeneral.com www.fujitsugeneral.com A subsidiary of Fujitsu General Limited