Heimdall Radar Traffic Detector

Similar documents
Heimdall Radar Traffic Detector

Heimdall Radar Traffic Detector

Heimdall Radar Traffic Detector

METHOD STATEMENT. Process. Document Authorisation Role Name Function Signed Prepared by:

600 Range Dialer Installation Manual. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Performance Specification for Above Ground On- Crossing Pedestrian Detection Systems

Networked Access Control Panel. Installation Guide

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

RS485 MODBUS Module 8AI

Public Safety DAS Annunciator Panel

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

OPERATION / INSTALLATION

Interface Modules for SENTRI

Installation and user manual for the BiWire / Conventional Repeater Panel

D-Tect 2 GJD300 Quad PIR Movement Detector

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Intelligent Security & Fire Ltd

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

1) This manual covers 4400, 5400 and 6400 fire alarm systems. The differences are described in the appropriate sections.

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

RMS/RPX Reader. User Manual

AE Liter Tank with Pump Installation Guide

RTD TEMPERATURE SENSING SYSTEM

Ax60 Carbon Dioxide Detector

5000 INSTALLATION GUIDE

ITS specification Over-height vehicle detection (ITS-08-02)

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Movement Detector GJD 300

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Operation and Maintenance Manual

Specification for Rising Bollards Control System

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Installation Instructions

Ax60+ Multi-Gas, Quick Connect Option

FlexZone SIX STEPS TO AFFORDABLE PERIMETER PROTECTION EASY TO INSTALL LOW TOTAL COST OF OWNERSHIP HASSLE-FREE OPERATION & MAINTENANCE HOW-TO GUIDE

Engineering Guideline. pac- Carriers Type Universal

New Silent Alert Fire Safe System

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

DESCRIPTION NOTE. Temperature and Humidity Sensors MODEL 1260B

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

/9308 External Battery Chargers Installation Instructions

PERMACONN PM1030 Includes DI300. Installation Manual

General Purpose IO Technical Manual

Installation Instruction Manual ILS-S

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

Door Release Power Supply

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Vega Devices.

Wallace & Tiernan Controllers & Analysers ChemTrim Disinfection Controller

Manual Comfort Air Curtain

T4000 Security Communicator

Silent Alert Fire Safe System

21-light Remote Annunciator. Owner s Manual

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Fratech Multipath-IP

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Installation Guide Atmospherix and Atmospherix A20

Esmi Sense FDP Fire detection panel with ALC2 loop controller

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

KM300 Carbon Monoxide Detection System Installation Manual

Fire Control Panel FS4000

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

Bionics Instrument. Alarm Handling. Gas Alarm Systems

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

OPERATING and SERVICE GUIDE USA - Coin in / Ticket out Feature.

M2500 Engine Controller Installation Manual

Multi-Zone Wireless Control Training Systems ( )

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Application, Installation, Operation & Maintenance Manual

Solar Separator Alarm Type Installation, Operation & Maintenance

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Installation, Operating and Servicing Instructions. Opus 800 Electric Cook & Hold Salamander OE8306

D-TECT Dual Tech. GJD360 Triple Technology External Detector

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

INSTRUCTION MANUAL A131 High Level Audible Warning System

HRX Technical Manual. Version 1.2

Product Specification

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

OmniCare EVC System. Installation & Commissioning Manual

FiRe mobile-2 Operation Manual

Transcription:

Heimdall Radar Traffic Detector Traffic Data Detector Installation Guide Document Authorisation Role Name Function Signed Prepared by: R. Martin Project Support Manager Reviewed by: A. Rhodes Lead Product Engineer Reviewed by: A. White Product Design Manager Authorised by: C. Whipps Technical Support Manager Document record Issue Date Comment/Revision Details Number 1 04/04/08 Initial Release 2 15/07/11 Electrical information updated 3 23/09/11 Updated Document This document is electronically held. This is an unpublished work, the copyright of which vests in Siemens Plc. All rights reserved. The information contained herein is the property of Siemens Plc. and is supplied without liability for errors or omissions. No part may be reproduced or used except as authorised by contract or other written permission. The copyright and the foregoing restriction on reproduction and use extend to all media in which the information may be embodied. Part Number: 667/HB/31900/370 Issue 3 Page 1 of 11

Contents 1 General...3 1.1 Part number...3 1.2 Tooling requirements...3 1.3 Performance Details...3 1.4 Electrical Details...4 2 Detector Installation...5 2.1.1 9-Pin Buccaneer connector...5 2.1.2 Output Cable (Standard)...6 2.1.3 Output Cable (with SiTOS)...7 2.1.4 Output Cable (with isolated 2 nd detector O/P)...7 2.2 DIP Switch Settings (PCB 1)...8 2.3 DIP Switch Settings (PCB 2) SiTOS only...8 2.4 Detector mounting methods...9 2.5 Detector alignment...9 Installation Quick Reference Guide...10 Part Number: 667/HB/31900/370 Issue 3 Page 2 of 11

1 General The Heimdall Above Ground Vehicle Detectors have been developed to provide the complete range of detection systems used in a modern traffic/pedestrian control installation. They incorporate state of the art radar antenna designs tailored to the specific requirements for each detector type. All detectors are housed within the same style of enclosure and are of minimal size to reduce the eye clutter associated with older types of equipment. All detectors can be readily installed onto both new and existing traffic signal control poles. Detectors come supplied with a standard interface cable together with the HA specified Bulgin Buccaneer connector. Existing sites can easily be upgraded with the Heimdall detector as the detector is compatible with existing above ground units. 1.1 Part number Part Number 667/1/31900/07x Traffic Data Detector Description Note: In the above table x relates to the particular option installed, thus: 0 Basic Detector 1 Basic Detector with RS485 Interface (SiTOS) 2 Basic Detector with Wireless Interface 3 Basic Detector with 2 nd Output 4 Basic Detector with 2 nd Output + Wireless Interface 1.2 Tooling requirements As well as a standard Installers tool kit, the following are required when installing or maintaining a Heimdall Detector: 1. 2mm Allen key for side access door and lid 2. T-8 Torx driver alternative tool for side access door and lid. 3. 13mm Socket spanner - for angular adjustment and installation of detector. 4. 19mm Ring spanner - for cable gland (DE only). 5. Small flat bladed screwdriver for DIP switch adjustment. 1.3 Performance Details Operating Range: Lane Width: Vehicle Approach Speed Range: Detector Location: Detector Mounting Height Range: Data Collected: Not applicable as the detector will be located above the lane being assessed. Typically 3.5m. 0Km/Hr (0 MPH) to greater than 112Km/Hr (70 MPH) Typically mounted on a gantry to place the detector centrally over the lane being assessed. Various heights (above the ground) can be accommodated from 3.0m to 7.0m. Vehicle Classification (2+1); Vehicle Counts and Detector Occupancy. Requires the use of a SiTOS enabled I/O board (see Section 2.3, below). Part Number: 667/HB/31900/370 Issue 3 Page 3 of 11

1.4 Electrical Details The Heimdall detector is capable of being powered from either: (a) 24V AC ± 20% (48 to 63 Hz), or (b) 10.8V to 24.8V DC (c) 24V Full wave rectified ± 20%. From Siemens ELV controller For information relating to the following: 1. Power consumption requirements of this model. 2. 24V AC & DC power supply options. 3. Permissible detector supply cable lengths. 4. Calculating 24V AC & DC supply cable feeds. 5. Cable length look up tables. Please refer to the Heimdall General Handbook (667/HB/31900/000). Part Number: 667/HB/31900/370 Issue 3 Page 4 of 11

2 Detector Installation Important Notes: a) When connecting this detector to a 24V AC source, please ensure that the 24V AC source is derived from an earthed secondary transformer (as used in standard traffic installations). b) Particular attention should be paid to the correct termination of the power supply wires. The RED wire should be used for the 24V AC/DC supply feed and the Black wire for the EARTHED supply return. c) When using a 24V AC supply, only use battery powered interface equipment (e.g. laptop, PDA). Do not connect mains powered/connected equipment to the Heimdall series of detectors, as this will cause the detectors to fail. d) When installing this detector with a Siemens ELV controller or a Siemens ELV controller additional supply, please ensure the RED wire of the interface cable is connected to the POSITIVE (common) connector, the BLACK wire is connected to the NEGATIVE (-24VDC) source and the GREEN (screen) is connected to the POSITIVE (common) connector. Figure 2-1 Connection of Heimdall detector to Siemens ELV controller 2.1.1 9-Pin Buccaneer connector All Heimdall detectors are equipped with a captive lead and a standard 9 pin Buccaneer connector (see Figure 2-2, below). The pin out for this connector is as specified in the Highways Agency Specifications: TR2505, TR2506 & TR2507. The Heimdall series of detectors provide additional facilities, to that specified in the HA documents, using the spare connections within the 9 way connector. These are outlined in the sections below. 3 4 5 2 9 6 1 8 7 Figure 2-2 Buccaneer Bulkhead Connector (front view) Part Number: 667/HB/31900/370 Issue 3 Page 5 of 11

2.1.2 Output Cable (Standard) Table 1: Output Cable (Standard) configuration for variants: 667/1/31900/xx0 & /xx2. Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen Green 4 Detector O/P #1&2 (Common) White 5 Detector O/P #1 (Normally Open)* Yellow 6 Detector O/P #1 (Normally Closed)* Blue 7 Violet 8 Orange 9 Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). Part Number: 667/HB/31900/370 Issue 3 Page 6 of 11

2.1.3 Output Cable (with SiTOS) Table 2: Output Cable (with SiTOS) configuration for variant: 667/1/31900/xx1. Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen/ RS485 Ground Green 4 Detector O/P #1&2 (Common) White 5 Detector O/P #1 (Normally Open)* Yellow 6 Detector O/P #1 (Normally Closed)* Blue 7 Detector O/P #2 (Normally Open)* Violet 8 SiTOS RS485 (Terminal A) Orange 9 SiTOS RS485 (Terminal B) Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). 2.1.4 Output Cable (with isolated 2 nd detector O/P) Table 3: Output Cable (with isolated 2 nd detector O/P) configuration for variants: 667/1/31900/xx3 & /xx4) Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen Green 4 Detector O/P #1 (Common) White 5 Detector O/P #1(Normally Open *) Yellow 6 Detector O/P #1(Normally Closed *) Blue 7 Detector O/P #2 (Common) Violet 8 Detector O/P #2 (Normally Open *) Orange 9 Detector O/P #2 (Normally Closed *) Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). Part Number: 667/HB/31900/370 Issue 3 Page 7 of 11

2.2 DIP Switch Settings (PCB 1) All Heimdall detectors are equipped with switches that enable the unit to be installed, for the majority of applications, without the need for any special terminal (handset) equipment. Access to these switches is gained by removal of the side cover. Before removal, note the cover s orientation and ensure it is replaced the same way round. The switches on the first PCB (Digital Processor) control the basic functions of this detector and are as listed in the following table: Note: Default settings are with all DIP switches set to 0 / OFF. SW 1,2: DIP Switch Number (PCB 1) Digital Processor 1 2 3 4 5 6 7 8 Detector Height 0, 0 = Height #1 5m 0, 1 = Height #2 6m 1, 0 = Height #3 7m 1, 1 = Height #1 SW 3: SW 4: SW 5: SW 6: SW 7: DFM 0 =Default monitor time (20hours inactive) 1 = fault monitor time is set by the Engineer s Terminal SW 8: Remote Configuration 0 = Disabled 1 = Enabled Key: 0 OFF 1 ON * Unidirectional detection ** Bidirectional detection Note: The switches provided on PCB 2 (Special Serial Interface card) control the operation of the Siemens Serial Interface (SiTOS), details of the switch settings for this PCB are shown in the table below (Section 2.3). 2.3 DIP Switch Settings (PCB 2) SiTOS only The SiTOS facility utilises the industry standard RS485, two wire serial communication technique. This allows a number of detectors to be attached to a common pair of lines thus giving the ability to interrogate the detectors individually. It is therefore necessary to assign a unique address to each detector on the common pair using the dual-in-line switch located on the Special Serial Interface card (see the table below for the PCB switch settings). DIP Switch Number (PCB 2) Special Serial Interface (SiTOS) 1 2 3 4 5 6 7 8 SW 1: Line Termination 0 = Disabled 1 = Enabled SW 2,3: SW 4 to 8: (SW 4 = MSB, SW 8 = LSB) Detector Address: 0, 0, 0, 0, 0 = Address 0 (00h) 0, 0, 0, 0, 1 = Address 1 (01h). 1, 1, 1, 1, 1 = Address 31 (1Fh) Part Number: 667/HB/31900/370 Issue 3 Page 8 of 11

2.4 Detector mounting methods This detector is typically mounted on a gantry. When mounting make sure that it is positioned such that it provides good coverage of the lane being assessed. Do ensure that it is mounted at an angle of 45 o to the road surface for optimum speed and traffic classification accuracy. 2.5 Detector alignment Detector Alignment When aligning the detector always ensure the following: 1. The detector is mounted at an angle of 45 o to the road surface. This angle will provide optimum speed and traffic classification accuracy. 2. The detector is mounted at a suitable location on a gantry ensuring good coverage of the lane being assessed. 3. The detector is aimed at a position as shown in the diagram below. Part Number: 667/HB/31900/370 Issue 3 Page 9 of 11

Installation Quick Reference Guide Electrical Connections Important Notes: a) When connecting this detector to a 24V AC source, please ensure that the 24V AC source is derived from an earthed secondary transformer (as used in standard traffic installations). b) Particular attention should be paid to the correct termination of the power supply wires. The RED wire should be used for the 24V AC/DC supply feed and the Black wire for the EARTHED supply return. c) When using a 24V AC supply, only use battery powered interface equipment (e.g. laptop, PDA). Do not connect mains powered/connected equipment to the Heimdall series of detectors, as this will cause the detectors to fail. All Heimdall detectors are equipped with a captive lead and a standard 9 pin Buccaneer connector. The pin out for this connector is as specified in the Highways Agency Specifications: TR2505, TR2506 & TR2507. The Heimdall series of detectors provide additional facilities, to that specified in the HA documents, using the spare connections within the 9 way connector. The wires from this connector should be terminated in accordance with the details shown in the table below. Output Cable (Standard) Output Cable (Standard) configuration for variants: 667/1/31900/xx0 & /xx2. Connector Pin No. Comment Colour Code 1 Detector Supply (24V AC/DC) Red 2 Detector Supply Common (0v) Black 3 Screen Green 4 Detector O/P #1&2 (Common) White 5 Detector O/P #1 (Normally Open)* Yellow 6 Detector O/P #1 (Normally Closed)* Blue 7 Violet 8 Orange 9 Brown Note: * This signal condition refers to the state when the detector is un-powered (detect state). For pinout and wiring details of the output cable for either the SiTOS or 2 nd output detector options, please refer to section 2.1.3 & 2.1.4 of this installation guide. DIP Switch Settings All Heimdall detectors are equipped with switches that enable the unit to be installed, for the majority of applications, without the need for any special terminal (handset) equipment. Access to these switches is gained by removal of the side cover. Before removal, note the cover s orientation and ensure it is replaced the same way round. The switches on the first PCB (Digital Processor) control the basic functions of this detector and are as listed in the following table: Note: Default settings are with all DIP switches set to 0 / OFF. DIP Switch Number (PCB 1) Digital Processor 1 2 3 4 5 6 7 8 SW 1,2: Detector Height 0, 0 = Height #1 5m 0, 1 = Height #2 6m 1, 0 = Height #3 7m 1, 1 = Height #1 Key: 0 OFF 1 ON * Unidirectional detection ** Bidirectional detection SW 3: SW 4: SW 5: SW 6: SW 7: DFM 0 =Default monitor time (20hours inactive) 1 = fault monitor time is set by the Engineer s Terminal SW 8: Remote Configuration 0 = Disabled 1 = Enabled Note: The switches provided on PCB 2 (Special Serial Interface card) control the operation of the Siemens Serial Interface (SiTOS), details of the switch settings for this PCB are shown in Section 2.3 of this installation guide. Part Number: 667/HB/31900/370 Issue 3 Page 10 of 11

Detector Mounting Methods This detector is typically mounted on a gantry. When mounting make sure that it is positioned such that it provides good coverage of the lane being assessed. Do ensure that it is mounted at an angle of 45 o to the road surface for optimum speed and traffic classification accuracy. Detector Alignment When aligning the detector always ensure the following: 1. The detector is mounted at an angle of 45 o to the road surface. This angle will provide optimum speed and traffic classification accuracy. 2. The detector is mounted at a suitable location on a gantry ensuring good coverage of the lane being assessed. 3. The detector is aimed at a position as shown in the diagram below. Part Number: 667/HB/31900/370 Issue 3 Page 11 of 11