SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Similar documents
Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

FlowJam Bulk Flow Detection

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

SCHMIDT LED Measured Value Display MD Instructions for Use

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Danfoss gas detection units

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Instructions for Use

IP65 High Bay Dual Sense Sensor

EHA Hoffmann International GmbH

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

User Manual WMF Cup&Cool WMF Cup

MANUAL Overflow sensor NVF-104/34-PF

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Danfoss gas detection units

COMPACT FLAME CONTROLLER CFC 100

FIRERAY 5000 range USER GUIDE

BN30 OPERATING MANUAL SOCKET THERMOSTAT TRT-BA-BN30-TC-001-EN

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

TDS 20 R / TDS 30 R / TDS 50 R

COMPACT FLAME CONTROLLER CFC 1000

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Instructions for Use

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

IP65 High Bay Dual Sense Sensor

Silicon Pyranometer GSM xx

Data sheet. Function description. Benefits

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

Gas cylinder scale Model GCS-1

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

COMPACT FLAME CONTROLLER CFC 2000

MANUAL Oil Level Sensor

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Wind Alarm Instrument

L / -014L / -015L

Door Release Power Supply

PolyGard 2-channel Gas Controller MGC-03

INSTRUCTIONS FOR USE

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Alarm System SECURE AS 302

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

Dry Block Heater Operating Manual

UV Flame Supervision System

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Operating Manual MS220DA

TTV 4500 / TTV 4500 HP / TTV 7000

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Instructions for the fan motor control system, SILVER C

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Wind Alarm Instrument x.x0x

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

User manual CTX 300 CO 2

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL. DECKMA HAMBURG GmbH. Type OMD-12. Oil-in-Water Monitor

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

IMPORTANT SAFETY INFORMATION

FLAME AMPLIFIER MODULE 3001

Plug-in Base, Long Range Sensor E3B2

Original operating instructions Safety switch with guard locking AC901S AC902S

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

L+T GASETECHNIK. Klöpper-Waldmann GmbH & Co. K G. Alarm unit LSG4

Sensero-868/915 AC, Sensero-868/915 AC Plus Nr , , ,

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Operation Manual for Drying Storage Cabinet with Drying Unit U-5002

WIRELESS MEASUREMENT SYSTEM OF GAS BOTTLES FILLING LEVEL WITH GAS LEAK DETECTION GMS 300. User Manual

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

FLAME AMPLIFIER MODULE 3001D

FDCW241 Radio gateway Mounting

Radio fire warning panel SRC 3000

Alarm Switchgear AS1-M

Frost Protection Thermostat

2CKA001473B System Manual Busch-Infoline. Handicapped toilet signal set 1510 UC

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Strip-Cut Shredder S5

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Copyright LIQUIDYN GmbH 08/2013 Version

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Operating manual. a Look Solutions 1 product

Carbon Monoxide CO Transmitter ADT-X3-1110

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

Technical data lumina MS4

1. Product description

smardy - pure water Reverse osmosis system YR100-A 75 GPD

Detector switch - Dual Tech

Transcription:

TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

CONTENTS 1 Introduction... 3 1.1 About this manual... 3 1.2 Usage according to regulations... 3 1.3 Label... 4 1.4 Symbols... 4 1.5 Safety instructions... 5 2 About the TDD1-MW traffic detector... 6 2.1 Application range... 6 2.2 Working principle... 6 2.3 Mounting... 6 2.4 Accessories... 6 3 Technical specifications... 7 3.1 Electrical connections... 7 3.2 Technical data... 7 3.3 Dimensions... 8 4 Configuration... 9 4.1 Key functions... 9 4.2 Detector functions model TDD1-MW30... 10 4.3 Detector functions model TDD1-MW75... 11 5 EC Declaration of conformity... 12 Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 2/13

1 Introduction In this chapter you will find preliminary remarks about the usage of the TDD1-MW traffic detector, as well as explanations about the structure of this manual and the usage of symbols. 1.1 About this manual On the following pages you will learn how to install and operate the device in an appropriate way. We attach great importance to the safe, appropriate and effective handling of this device. It is therefore important to read this manual thoroughly before using the device. In the manual you will find important instructions helping you to avoid danger and to prolong the reliability and durability of the device and the accessories. For your own safety you should read the safety instructions. Follow the instructions closely in order to avoid danger for yourself and others or damage to the device. If you have any questions about the TDD1-MW which are not answered in this manual, or if you have problems understanding the descriptions, please contact: SWARCO TRAFFIC SYSTEMS GmbH Business Unit Detection Niederkircher Straße 16 54294 Trier Germany www.swarco.com/sts 1.2 Usage according to regulations The TDD1-MW traffic detector is solely suited for the detection of vehicles in traffic. Any further usage is not appropriate. Do not use the TDD1-MW for any other purpose. Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 3/13

1.3 Label SWARCO TRAFFIC SYSTEMS GMBH The TDD1-MW is provided with a quality label and serial number. You will need the indications when talking with the customer service, e. g. ordering accessories or spare parts. Note here the serial number and name of the device in order to have them available when needed: Serial number: Device identification: This manual is valid for devices with the following order numbers: RD_TDD1-MW30 RD_TDD1-MW75 D.000.604.473 D.000.604.568 CE-label: 1.4 Symbols In several places throughout this manual you will find the following symbols stating important safety instructions: ATTENTION! This symbol indicates dangers which might cause damage to people or property NOTE This symbol indicates information for installation and function of the device Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 4/13

1.5 Safety instructions Read the following safety instructions thoroughly and observe them carefully. They are stated to ensure your own safety and the safety of others and to avoid damage to the device or accessories. ATTENTION! Danger of electricity! Make sure that no liquid may get inside the device. If this happens, interrupt the power supply to the device at once. If you notice any damage, e.g. broken or crushed cables, damaged plugs, enclosures etc., turn off the device at once, interrupt the power supply and make sure that the device cannot accidentally be turned on again. The device may only be installed, brought into service and repaired by an electrotechnical expert. Inappropriate operation, improper maintenance or not observing the instructions in this manual can lead to danger. Any malfunction of the device which may limit the safety of its users or others must be removed immediately. All warning and safety labels on the device must be observed and kept complete and legible. The appropriate usage must be observed by all means. For damage resulting from inappropriate usage the manufacturer will not undertake any liability. The device must not be used as a safety component in the sense of the European Directive 98/37/EC ("Machinery Directive ). In systems with high risk additional safety measures are necessary. The operator of the device must ensure that the chosen means of operation will not cause damage to material or danger to people and that all security and safety installations are present and functioning. Before installation and first operation please observe the instructions in the manual. The manual must be available at the site of usage at any time. It must be read thoroughly and applied appropriately by the person responsible for the operation, maintenance and service of the device. NOTE Our products are in a constant process of improvement and advancement. Because of this, read the current manual thoroughly before installation and first operation. Without prior consent of the manufacturer, no modifications, neither mechanical nor electrical, may be done. Only parts that have the consent of the manufacturer may be used for backfitting or as accessories. Any violations will lead to the termination of conformity and the manufacturer s warranty. The user will subsequently bear the risk. Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 5/13

2 About the TDD1-MW traffic detector 2.1 Application range The detectors of the TDD1-MW series have been developed for a range of applications that require robust and reliable detection: Green-phase request or extension at traffic lights, with possibility to discriminate by vehicle driving direction Speed-dependent detection of vehicles Door sensor: As detector for auto-operation of doors 2.2 Working principle The TDD1-MW detectors detect moving objects by means of the frequency shift of the reflected microwave vs. the transmitted waves. Several application-dependent features can be configured easily and effortlessly using the IR remote control (extra accessory): Direction-discrimination (approaching, receding, both) Detection range (depending on model) Minimum speed threshold (4 km/h, 8 km/h) Auto-timer output activation (off, 90 s, 150 s) Feedback LED on front of detector (on, off) 2.3 Mounting The recommended mounting location is on a pole at the side of the road, approximately 1 to 5 m above ground. 2.4 Accessories IR Remote Control: To customize the settings of the detector, an infrared remote control is required. The remote control is an extra accessory and has to be ordered separately. Order number: RD_TDD1_IRF (D.000.604.474) Mounting Accessories: Pole mount adapter for mounting the detector on a round pole. The pole mount adapter is an extra accessory and has to be ordered separately. Order number: RD_TDC_PMA (D.000.604.475) Connection Cable: An according connection cable is necessary for the electrical connection of the detector. This cable is an extra accessory and has to be ordered separately. Order number: RD_TDD1_Cable15m (D.000.611.203) Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 6/13

3 Technical specifications 3.1 Electrical connections In order to easily mount or quickly exchange the detector, the cable is connected with the detector by means of a plug. The pin assignment of the socket is listed as follows: Pin Color code* Connection 1 White V+ Supply voltage (5 48) V DC / (12 43) V AC 2 Brown V- Supply voltage / GND 3 Green Relay: Common 4 Yellow Relay: Normally open 5 Grey Relay: Normally closed 6 and 7 Pink/Free Reserved *Connection code for the optionally available connection cable Table 1 Pin assignment cable socket 3.2 Technical data Supply Voltage Power Consumption Output / Switch* Function indication Turn-on time (5 48) V DC / (12 43) V AC typ. 50 ma @ 12 V DC Dimensions See Figure 1 Case Material Weather protection Weight Doppler Radar Detection Range Low speed threshold Operating Temperature Humidity Sealing Relay, SPDT / 300 V AC / 2 A / 60 W Tri-color LED on front of detector typ. 1 second after power on Polycarbonate, dark grey Stainless steel V4A approx. 700 g incl. bracket (approx. 560 g with plug) K-Band 24.05 GHz 24.25 GHz TDD1-MW30: 30 m nominal TDD1-MW75: 75 m nominal 4 km/h / 8 km/h (selectable) -40 C to +70 C 95 % RH max. IP 64 splash proof * The maximum voltage on the output must not exceed the supply voltage! Table 2 Technical data Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 7/13

3.3 Dimensions Figure 1 Dimensions (incl. plug) Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 8/13

4 Configuration The different application-dependent functions can easily and comfortably be configured by means of the optionally available IR remote control. Two different remote control devices are currently available. 4.1 Key functions Key Function Front LED flash pattern Directional discrimination Low speed threshold Detection Range Periodic auto-trigger Feedback front-led Table 3 Key functions 1. Press until the detector s feedback LED shows the color of the function (next to the key on the remote) you d like to access. 2. Press the function-key until the color of the feedback LED corresponds to the desired setting (see table above). 3. Press function-key again to confirm the new setting. Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 9/13

4.2 Detector functions model TDD1-MW30 Figure 2 Detector functions model TDD1-MW30 Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 10/13

4.3 Detector functions model TDD1-MW75 Figure 3 Detector functions model TDD1-MW75 Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 11/13

5 EC Declaration of conformity Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 12/13

SWARCO TRAFFIC SYSTEMS GMBH Niederkircher Straße 16 D-54294 Trier www.swarco.com/sts 2015 All rights reserved Niederkircher Straße 16, D-54294 Trier, T. +49-651-81002-0, F. +49-651-81002-979, E. detection@swarco.de 13/13