Operating Instructions

Similar documents
Operating Instructions

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Operating Instructions

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Operating Instructions

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

For more information, please visit or call toll free at

THIS MANUAL COVERS THE FOLLOWING SYSTEMS:

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

Safety Photo Beam UL MONITORED DEVICE

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

MD12-1 Vehicle Loop Detector

Installation/Owner s Manual Models 1504 / 1506

MD12-2 Vehicle Loop Detector

D-TEK -MS Vehicle Loop Detector. Operating Instructions

Operations Manual. Motion Detector Module Model ZS10

ENGINEERED PARKING SYSTEMS MODEL 3416D

Operating Instructions. For. Alarm Control Module. Model SSR 500

Driveway Alarm INSTALLATION MANUAL.

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

DSP-13 Tri-Axis Detection (TRIAD TM ) System

WVD100. EZ Loop. Product Manual. Wireless Vehicle Detector. Installation Instructions Program Instructions. AP100 Relay Board S200 Sensor

MANUAL RESET ALARM RELEASE

MODEL B2 INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Public Safety DAS Annunciator Panel

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

RK-05 Combustible Gas Transmitter Operator s Manual

DOOR MONITORING/DURESS SYSTEM

MANUAL RESET ALARM RELEASE BOX

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

MBCE-110/230FR Flame Sensor Module

RELEASE DEVICE CONTROLS

Installation Instructions. CAR COMING Pedestrian Alert Safety Signs (PASS)

BLG77 Rising Fenced Barrier

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

MANUAL RESET ALARM RELEASE

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

RK CO 2 Transmitter Operator s Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Overload LED On & Power LED On

2011 DA-500 BURIED SENSOR SYSTEM INSTALLATION AND OPERATION MANUAL

MULTI-STAGE CHILLER CONTROL

MBCE-110/230FR Flame Sensor Module

User Manual 120/240/300 Outdoor Motion Detector

RK Hydrogen Sulfide Transmitter Operator s Manual

Flame Rod Manual. Publication Rev A

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

INTREPID Perimeter Intrusion Detection System

Exit Stopper. STI-6400 Series

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

CabLite Luminous Auto Light Control Installation Manual

RK Carbon Monoxide Transmitter Operator s Manual

Remote Chexit Module (RCM) System. General Information

Troubleshooting Manual

Product Manual. TZ Analog Sensors. TZ Sensors 8115CF 8116CF 8117CF 8118CF. Date: January 2015 Document Number: _B

The Clark-Reliance Corporation TWIP System Installation and Maintenance Instructions - Form E112 -

Power Supply Display Module PSDM. Installation and Operation Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

30.45 Electric Release PDRP-2001

DCU 305 R2/R3. Troubleshooting Manual

MBCE-110/230UV Flame Sensor Module

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

INTREPID Buried Cable Perimeter Intrusion Detection System

FLT93 Installation, Operation and Troubleshooting Guide

DE5300 Delayed Egress System. General Information

Electric Release Panel Wiring Tips

Exit Stopper. STI-6400 Series

EVO192 v3.0 Fire and Burglary What s New

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

SAFETY INFORMATION AND WARNINGS

Pioneer-R16 Gas Monitor Operator s Manual

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Carbon Monoxide Transmitter

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Section PERIMETER SECURITY SYSTEMS

INTREPID Buried Cable Perimeter Intrusion Detection System

Engineering Specifications

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

INSTALLATION INSTRUCTIONS

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

ELECTRO-FENCE TM. Fence Protection System. Installation Manual. EF_Install_V2

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

TECH SHEET DO NOT DISCARD PAGE 1. If unsuccessful entry into diagnostic mode, actions can be taken for specific indications:

MODEL RWM RADIATION WASTE MONITOR LUDLUM MODEL RWM RADIATION WASTE MONITOR INSTALLATION MANUAL

Basin Heater. user manual INSTALLATION OPERATION MAINTENANCE

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

TFD-1 Installation & User s Guide

Transcription:

CS101 CarSense Vehicle Motion Detector Operating Instructions

CAUTIONS AND WARNINGS Never use the CS101 as a safety reversing or presence detection system. The CS101 requires that a vehicle be moving for detection. This product is an accessory or part of a system. Always read and follow the manufacturer s instructions of the equipment before connecting this product. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death. DO NOT INSTALL PROBE IN HOT ASPHALT PROVIDE AN EARTH GROUND CONNECTION USING GROUND ROD PER INSTALLATION INSTRUCTIONS DO NOT EXCEED POWER SUPPLY VOLTAGE RATING 41VDC or 29VAC ALLOW 3 MINUTES AFTER POWER UP FOR STABILIZATION CS101 is sensitive to metal objects that move through its field, including bicycles, horses, small vehicles or metal in shoes. Reduce the sensitivity as required to eliminate detection. In areas with high pedestrian traffic, the probe may be buried up to 24 deep to prevent triggering the detector by the metal in shoes. CS101 Operating Instructions 2

PRODUCT OVERVIEW The CS101 is a compact vehicle motion detector that operates by detecting changes in the earth s magnetic field that occur near the probe. These changes are produced by the movement of ferrous materials such as cars or trucks within the probe s range. The CS101 uses the CS101 series direct burial probes placed adjacent to a roadway or buried in a concrete or asphalt roadway. The probe features a 12ft. detection range that is dependent on the speed and size of the vehicle. The probe is available in a wide variety of cable lengths. The CS101 features adjustable sensitivity and output on time. A green LED is indicates that power is applied to the unit while a red LED indicates detection. The output consists of form C relay contacts (N.O, N.C., C). The CS101 may be used as a free exit sensor in both commercial and residential applications. The detector is not for use as a presence detector. When presence detection is needed, use the Ultra II DTEK and inductive loop. Specifications Range sensitivity Sensitivity adjustment Output on time adjustment Surge protection Relay output configuration Relay contact rating Detect indicator Power indicator Power Standby current Detection current Operating temperature CS101 housing material CS101 dimensions (L x W x H) CS101 weight Probe housing material Probe dimensions (L x Dia.) Probe cable 12 ft. @ 5mph min. speed Dependent on mass and speed 0.5 6 seconds Probe input circuitry protected by surge suppressors Form C (SPDT) 1A @ 24VDC, 1A @ 120VAC Red LED Green LED 9 41VDC or 6 29VAC and 110VAC Model 2.5mA 50mA -40 C 82 C (-40 F 180 F) 0 95% relative humidity Polycarbonate 3.35 (84mm) x 1.6 (41mm) x 2.2 (55mm) 0.25 lbs. (113g) PVC water-tight 17 (432mm) x 1 (25mm) 3-wire, shielded, direct burial CS101 Operating Instructions 3

OPERATION After allowing a 3-minute stabilization time the CS101 is ready for use. It is possible that the detector will cycle during the power up stabilization period, this is normal. The CS101 relay contacts provide the means of indicating to the gate operator or other external equipment, that a vehicle has been detected. Since the CS101 is designed to detect motion it is not suitable for use as a presence detector. The green LED on the CS101 front panel indicates that power is applied to the unit and should always be on. The red LED on the front panel indicates detection and the activation of the output relay. The sensitivity adjustment allows the installer to set the system sensitivity for reliable operation. Rotate the adjustment counter-clockwise for minimum sensitivity and clockwise for maximum sensitivity. The output delay adjustment controls how long the output remains activated upon detection; minimum is approximately ½ second while maximum is approximately 6 seconds. Sensitivity is a function of speed and mass; the slower a vehicle is moving, the closer the vehicle must pass the probe to trigger the detector. CONTROLS AND INDICATORS CS101 Operating Instructions 4

INSTALLATION GUIDELINES POWER SUPPLY Do not exceed 41VDC or 29VAC. Power requirements are 9 41 VDC or 6 29 VAC PROBE STANDARD INSTALLATION BURY PROBE 8 12 DEEP HIGH PEDESTRIAN TRAFFIC BURY PROBE 24 DEEP CS101 is sensitive to metal objects that move through its field, including bicycles, horses, small vehicles or metal in shoes. Reduce the sensitivity as required to eliminate detection. In areas with high pedestrian traffic, the probe may be buried up to 24 deep to prevent triggering the detector by the metal in shoes. Do not install the Probe or lead wire near or parallel to: Low voltage lighting wires Telephone lines or intercom systems Electric motors or control relays Overhead power lines and transformers or underground power lines Cell phone towers, TV towers or communications links Moving metal flagpoles, fences, gates or horses with metal shoes Do not mount on any moving surface such as bridges or walkways may vibrate under traffic Underground water lines Probes are available in various cable lengths, when possible select the appropriate cable length for the installation. If it is necessary to extend the cable length, use a high quality lead-in cable suitable for direct burial, and a high quality, watertight cable splice to prevent moisture from entering the cable causing false triggering. A splice kit (Part no. 3M SPLICE KIT) and lead-in wire is available from EMX. All splices must be waterproof. When there is a high incidence of damage from burrowing animals or other potential damaging activities, it is recommended that the cable be placed in plastic conduit (1 ½ I.D.) to prevent damage to the cable. Damage to the cable jacket may allow moisture to enter the cable causing false triggering. When placing the probe in plastic conduit, use foam or tape to assure that the probe does not move or vibrate. It is recommended that the conduit be sealed to prevent water from collecting in the conduit. The probe must always be installed in such a way that it remains completely motionless. Any movement will cause the probe to trigger. CS101 Operating Instructions 5

CS101 module The detector is sensitive to minute changes in the magnetic field around the probe. Power lines, transformers, and other electrical devices located in the vicinity of the probe that produce transients could cause disturbances in the magnetic field that may result in triggering the detector. Avoid installation of the probe near these devices. The detector sensitivity is a function of mass and speed. A larger, fast moving vehicle will be detected at a greater distance than a smaller, slow moving vehicle. With this in mind, consider the distance of the probe to normal residential traffic, truck traffic, railroad, etc. As a general rule, probe distance to a road way should be a minimum of 40 while probe distance to a railway should be a minimum of 100. IMPORTANT: EARTH GROUND CONNECTION The CS101 contains transient protection devices to guard the sensitive electronic circuitry from damage and false triggering due to electrical transients caused by lightening or other sources. Always provide a good earth ground. A 5ft copper rod or cold water pipe provides a sufficient earth ground connection. Both the probe shield and PIN 6 of the CS101 must be connected to this earth ground. PROBE INSTALLATION ADJACENT TO ROADWAY Please read INSTALLATION GUIDLINES prior to installation. When the detector is set to maximum sensitivity (full clock-wise on the sensitivity adjustment) detection distance is approximately 12ft at a speed of 5mph. At higher speeds, 10-15mph, detection distance can exceed 12ft. 1. Prior to permanent installation adjacent to the roadway, place the probe in the desired location; connect the probe to the CS101 and power, output contact and earth ground to the intended equipment. Both the probe shield and PIN 6 of the CS101 must be connected to the earth ground (reference EARTH GROUND CONNECTION in the INSTALLATION GUIDELINES section). 2. Place the probe parallel to the roadway (driveway) in the desired location. 3. Apply power and allow 3 minutes warm-up for system stabilization. 4. Set sensitivity to minimum and delay to maximum. 5. Drive the vehicle past the probe at a typical speed and to the far side of the roadway. 6. Repeat this step while gradually increase the sensitivity until the system detects the vehicle. 7. Bury the probe approximately 8-12 deep or 24 deep (see INSTALLATION GUIDELINES) at this location and repeat the previous sensitivity check (step 2-5), adjust the sensitivity as necessary to detect the vehicle. A higher sensitivity setting than required to detect the vehicle makes the system more vulnerable to triggering from unintended sources such as movement of other objects in the sensitive area or other electrical disturbances. CS101 Operating Instructions 6

Typical Installation PROBE INSTALLATION IN A ROADWAY Please read INSTALLATION GUIDLINES prior to installation. DO NOT INSTALL IN HOT ASPHALT When the detector is set to maximum sensitivity (full clock-wise on the sensitivity adjustment) detection distance is approximately 12ft at a speed of 5mph. At higher speeds, 10-15mph, detection distance can exceed 12ft. 1. The probe should be positioned in the center of the roadway, perpendicular to the direction of traffic. Place the probe in plastic conduit to prevent damage to probe and cable. Probe should be located at approximately 2 depth in concrete or asphalt. The probe may be located prior to paving, or a cut may be made in the pavement for installation. No rebar should be above the probe. 2. Once the probe is installed, connect the probe to the CS101 and power, output contact and earth ground to the intended equipment. Both the probe shield and PIN 6 of the CS101 must be connected to the earth ground (reference EARTH GROUND CONNECTION in the INSTALLATION GUIDELINES section). 3. Apply power and allow 3 minutes warm-up for system stabilization. 4. Set sensitivity to minimum and output delay to maximum (approximately 6 seconds). 5. Drive the vehicle over the probe at a typical speed and each side of the roadway. 6. Repeat this step while gradually increase the sensitivity until the system detects the vehicle. A higher sensitivity setting than required to detect the vehicle makes the system more vulnerable to triggering from unintended sources such as movement of other objects in the sensitive area or other electrical disturbances. CS101 Operating Instructions 7

Troubleshooting Symptom False triggering Possible cause Electrical disturbances Damaged probe cable Moisture in the probe cable Movement in the probe s environment Possible solutions 1. Verify that the earth ground connection to the CS101 and the probe shield is secure. If the connection is not secure, reconnect to the earth ground and retest the system. 2. Inspect the area around the probe for any metal object that may move such as signs or fences. 3. Disconnect the probe wires and see if the false triggering continues. If the false triggering stops, check the probe as outlined below. If the false triggering continues, disconnect the power and temporarily connect a 9V battery to the CS101 and reconnect the probe. Wait 3 minutes for the system to stabilize. If the false triggering stops, consider using a separate power supply for the CS101 such as a 120VAC to 12V power converter (min. 100ma). Re-connect the probe and test the system. 4. If the false triggering continues, inspect the area around the probe to see if any metallic objects may be subject to any movement. These may include fences, flagpoles, signs, etc. Other possible causes are electrical power lines, electric motors and high power lighting. Checking the probe If the false triggering stops when the probe is disconnected and other possible causes have been ruled out, then the likely cause is damage to the probe cable. A gross check may be performed on the probe as follows: 1. Disconnect the probe wires from the CS101. 2. Using a DVM set to measure ohms, verify that the resistance is 950 ohms +/- 10% the black and red wires. If not, then the probe/cable is defective. 3. Set the DVM to measure a minimum of 20 megohms and check the resistance between the red wire and the shield wire. Verify that the meter indicates open (infinity). Repeat this measurement on the black wire to the probe shield wire. If either measures a value, then there is moisture or damage to the probe and it must be replaced. Symptom No output (but red LED indicates detection) Possible cause Bad connection Failed relay Checking the CS101 output contacts 1. Disconnect the output contacts from the operator. 2. Connect a DVM, set to read ohms, to the COM and N.O. contacts. 3. The DVM should read open (infinity). Move a metal tool over the length of the probe, verify that the red LED turns on and that the DVM reads less than 10 ohms. CS101 Operating Instructions 8

Symptom No detection Possible cause Minimum 5 mph Bad connection Faulty power connection Failed relay 1. Check to see if the detection LED turns on, if so, check the relay output and related connections. 2. Verify that the green LED is on, if not, check the supply voltage using a DVM. Verify the voltage is 9 41VDC or 6-29 VAC. Wiring diagram TO POWER + 20% - Relay 2 Connections to "Open Only" terminals in operator or Annunciator 6 7 PROBE BLACK WIRE PROBE RED WIRE PROBE SHIELD WIRE AND EARTH GROUND Relay 1 Connections to "Open Only" terminals in operator or Annunciator CS101 Operating Instructions 9

Pin no. Description 1 Power + (9 to41vdc or 6-29VAC) or 110 VAC model 2 Power ground (9 41VDC common or 6-29VAC) or 110 VAC model 3 RELAY 1 - N.O. (relay, normally open contact) 4 RELAY 1 - Common (relay common contact) 5 RELAY 1 - N.C. (relay, normally closed contact) 6 Probe shield wire Earth ground (provides connection for transient and noise suppression devices) (reference EARTH GROUND CONNECTION in the INSTALLATION GUIDELINES section) 7 Probe (red wire) 8 Probe (black wire) 9 RELAY 2 - N.O. (relay, normally open contact) 10 RELAY 2- Common (relay common contact) 11 RELAY 2 - N.C. (relay, normally closed contact) Ordering information XC101-LV XC101-110 CarSense Vehicle motion detector, 9 41VDC and 6 29 VAC CarSense Vehicle motion detector, 110 VAC Accessories LD-11B Socket base, black, 11-pin, DIN rail mount (1 included) LD-11 Socket base, gray, 11-pin, DIN rail mount HAR-11 Connector, 11-pin, free-hanging with 36 wire harness 240-56857 Power convertor, 110VAC to 12VDC PROBE-50 PROBE-100 PROBE-150 PROBE-XXX CS 101 direct burial probe, 50 ft. lead-in wire CS 101 direct burial probe, 100 ft. lead-in wire CS 101 direct burial probe, 150 ft.lead-in wire CS 101 direct burial probe, enter required lead-in wire length (ft.) CS101 Operating Instructions 10

Warranty CS101 Operating Instructions 11

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America WEB http://www.emxinc.com E-mail salessupport@emxinc.com Telephone (216) 518-9888 Fax (216) 518-9884 Revision 1.4 8.4.11 CS101 Operating Instructions 12