Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher

Similar documents
5.5.1 General CD/30 (Oil Condensing Boiler Installation Assessment Form) General Technician Stationary...

TECHNICAL BOOK 4: OIL FIRED APPLIANCE & SYSTEM INSTALLATION REQUIREMENTS

ONLINE VERSION ONLINE VERSION

OFTEC s role in promoting safe domestic oil storage

Building Regulations Update. by Eamonn Smyth

Title: Room-sealed fanned draught flue systems concealed within voids

Permanent Ventilators (for the Supply of Combustion Air)

Riva Studio Dedicated Sealed External Air Kit

Annex 5a Solid fuel (Domestic) Annex 5a Common Minimum Technical Competency Requirements for Solid fuel burning appliance installation (domestic)

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Introduction ... The HETAS Guide. to Approved Solid Fuel, Wood and Biomass Products and Services. List no. 24 HETAS 2018

Technical Bulletin 005(B) Developed with Building Standards Scotland

Twin Wall Installation Instructions And Maintenance Guide

Commissioning of Heat Producing Appliances Burning Solid Fuel

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

SFA Guide to Building Regulations and Solid Fuel Heating

Technical Bulletin 008 (Edition 2) CIP-RACL Developed by Industry

Safety Alert New Gas Regulation 2013

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

REGULATED QUALIFICATIONS FRAMEWORK (RQF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Carbon Monoxide Safety

ARCHIVED. Compliance Document for New Zealand Building Code Clause G4 Ventilation Second Edition. Prepared by the Department of Building and Housing

INSTALLATION AND OPERATION MANUAL

Importance of a Draught Regulator

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

CHIMNEYS AND VENTS CHAPTER 8

HHIC consumer guide to gas boiler servicing

Eligibility criteria

Wet stove installation guide

Domestic Gas Safety Assessments (DGA) Competency Assessment Certification Scheme for Registered Gas Installers

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

DOMESTIC SMOKE. working for a cleaner, quieter, healthier world

Technical Bulletin. Concealed extended flues

Technical Guidance CE Marking of Metal Chimneys and Flues

5.5 CD/14 (Warning & Advice Notice)

Protect Safety Alarms

Stockton 7 & 8 Inset Convector Stove

Introduction. General. Other regulations. British Standards and European Technical Specifications

CHAPTER 8 CHIMNEYS AND VENTS

CHAPTER 8 CHIMNEYS AND VENTS

2012 INTERNATIONAL FUEL GAS CODE VENTS

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

Microgeneration Certification Scheme: MCS 008

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

GB162 Concentric Horizontal Vent Kit

Energy Efficiency Standards

Firebird Smoke Exempt Inset Stove

Installation & User Supplement

Introduction. Products conforming with a European Council Directive. CE marked construction products. Other regulations

Appendix T: Improvement measures

Flueing and ventilation for gas appliances of rated input not exceeding 70 kw net (1st, 2nd and 3rd family gases)

ASX7-5-IOM-3 J

WOLVERTON STOVES U S E R M A N U A L S h A N d o N / A R d L E i g h

Appendix T: Improvement measures for Energy Performance Certificates

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

ASX7-4-IOM-6 J

Exhaust Duct Design Page 1 of (C)

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

Installation Instructions. Rayburn 300W Wood Burning Cooker

Installation & User Supplement

SIZING HANDBOOK & APPLICATION GUIDE

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

JEREMIAS GROUP. CE MARK according to EN / 2.

Approved. Document. Sanitation, hot water safety and water efficiency. The Building Regulations 2010

2015 MECHANICAL CODE REQUIREMENTS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Assessment Schedule - TS.6

AS Australian Standard. Domestic solid fuel burning appliances Installation. This is a free 6 page sample. Access the full version online.

Side by side. Cascade Venting System for RTG 199HE. Extension Set for units 3 or Installation instructions

Hanwood Wood Stove. (Smoke Exempt)

Westbury Wood Stove. (Smoke Exempt)

AS AS Australian Standard. Industrial fuel-fired appliances. This is a free 9 page sample. Access the full version online.

SIZING HANDBOOK & APPLICATION GUIDE

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

Dorrington Wood Stove

Annex 4a Common Minimum Technical Competency Requirements for Oil Appliance Installation Work (Domestic)

INSTALLATION INSTRUCTIONS FOR FLUE KIT

Technician s guide to best practice FINAL Draft v October Flues, chimneys and combustion air ventilators.

Back to back. Cascade Venting System for RTG 199HE. Basic Set for units 1 and Installation instructions

Condensation. Some causes, some advice. GGF Condensation Brochure_web.indd 1

6.6.3 Minimum Provision for New Systems in New Dwellings Minimum Provision for New/Replacement Systems in Existing Dwellings

HEAT YOUR HOME SAFELY

Do not use this vent pipe or fittings for venting incinerators of any kind.

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

Ludlow Wood Burning Smoke Exempt Stove

Inspection Checklist Mechanical Rough in

Shawbury Wood Stove. (Smoke Exempt)

IGEM/G/5 Edition 2 Communication 1762 Gas in multi-occupancy buildings

Little Wenlock Classic

Buying & Installation Guide

ACS.CoCDN1 SAFETY ASSESSMENT CRITERIA CHANGEOVER NON-DOMESTIC TO DOMESTIC NATURAL GAS

Examples of Heat Pumps in DEAP

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

A6VS VENTILATION STANDARDS

General safety precautions English

INSTALLATION AND SERVICE MANUAL

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

Transcription:

Part J of the Building Regulations: Changes for 2010 Tuesday 28 th September 2010 Presenter: David Bleicher 1

The Building Regulations The England & Wales Building Regulations are legal requirements that apply whenever building work is carried out they are not retrospective They contain Functional Requirements such as: Combustion appliances shall have adequate provision for the discharge of products of combustion to the outside air Requirements are generally contained in parts A to P of schedule 1 of the Building Regulations These requirements are supported by guidance in 18 Approved Documents published by the Department for Communities and Local Government (CLG) 2

The Approved Documents The Approved Documents provide practical guidance on meeting the functional requirements of the Building Regulations They are not the only acceptable way of meeting the Functional Requirements They only provide guidance on common types of building work Relevant requirements are reproduced in the Approved Documents. Building Regulations and Approved Documents can be downloaded from www.planningportal.gov.uk 3

Approved Documents can t possibly apply to every type of building! 4

Legal Structure Enabling (parliamentary) legislation Building Act 1984 Regulations (statutory instruments) Building Regulations 2000 + Amendments Approved Documents Approved Guidance 2nd Tier Documents 3rd Tier etc. 5

Approved Document J: Combustion Appliances and Fuel Storage Systems Approved Document J applies to things like boilers, fires and oil tanks There are a number of health and safety hazards associated with these if not correctly installed, including fire, explosion, carbon monoxide poisoning and pollution of drinking water Part J, and the guidance supporting it, needs to be periodically reviewed in the light of changes in technology and standards as well as operational experience and new research. 6

Changes to Part J The Old Approved Document J dates from 2002 During 2009, an industry working group met to discuss changes to Part J A draft Approved Document J was produced and this went out to consultation from June to September 2009 This was separate from the Parts F and L consultation that ran around the same time Changes to Parts F, J and L of the Building Regulations were published in March 2010, followed by revised Approved Documents in April 2010 These come into effect on 1 st October 2010 7

Transitional Arrangements The changes don t take effect all at once If work is started before 1 st October 2010, the old regulations will still apply If the work is considered minor works or is carried out by a member of a competent persons scheme and is started before 6 th April 2011, the old regulations will still apply If an application is made before 1 st October 2010 and work is started before 1 st October 2011, the old regulations will still apply Otherwise, the new regulations will apply from 1 st October 2010 8

Requirement J1: Air Supply The Requirements of Part J Requirement J2: Discharge of products of combustion Requirement J2A: Warning of release of carbon monoxide (new requirement for 2010) Requirement J3: Protection of building Requirement J4: Provision of information Requirement J5: Protection of liquid fuel storage systems Requirement J6: Protection against pollution All of these requirements exist purely for health and safety purposes (not energy efficiency etc.) 9

Carbon Monoxide Alarms There is only one change to the Building Regulations: J2A: Where a fixed combustion appliance is provided, appropriate provision shall be made to detect and give warning of the release of carbon monoxide Requirement J2A only applies to fixed combustion appliances in dwellings Note that this requirement applies to all fixed combustion appliances in dwellings, regardless of fuel type or appliance output. ADJ 2010 states what appropriate provision is for solid fuel appliances up to 50kW (more about this on later slides). Carbon monoxide alarms can still reduce the risk of poisoning from other types of appliance. 10

Approved Document J 2010: Combustion Appliances and Fuel Storage Systems Section 1 deals with combustion appliances in general In addition to section 1 Section 2 deals with solid fuel (from 2010 specifically including solid biofuel) burning appliances with a rated output up to 50kW Section 3 deals with gas burning appliances with a rated input up to 70kW (net) Section 4 deals with oil (from 2010 specifically including liquid biofuel and blends) burning appliances with a rated output up to 45kW No specific guidance is provided for larger appliances Section 5 deals with liquid fuel storage and supply 11

Carbon Monoxide Alarms 12

Carbon Monoxide Alarms Carbon monoxide poisoning is more likely for solid fuel installations than for natural gas though overall numbers of deaths are low Reasons for difference in CO risk between gas and solid fuel appliances: Most gas appliances are room sealed so flue gases should not enter the living space even under fault conditions Gas appliances are subject to stringent testing and certification Installation of gas appliances is more tightly regulated than solid fuel Gas appliance are less subject to fuelling variations than solid fuel. 13

Carbon Monoxide Alarms In support of the new requirement J2A, guidance has been added to section 2: New or replacement solid fuel appliances in dwellings require carbon monoxide alarms Alarms should have a lifetime battery or be mains powered as a fixed installation (not plug-in) Alarms should comply with BS EN 50291:2001 Alarms may be on the ceiling or high up on the wall Alarms should be in the same room, and between 1m and 3m horizontally from the appliance It should be noted that this applies to all solid fuel appliances up to 50kW, irrespective of the fuel, even if they are room sealed this is because there is no standard for room-sealing of these appliances 14

Concealed Flues Concealed flues are increasingly common for gas boiler installations Extended flue kits are available for many boilers Provides more flexible boiler location (does not need to be located on an outside wall) If flues are badly installed then faults can develop in use leading to leakage of flue gases 15

Access to Concealed Flues New guidance has been added to section 1 for 2010. Concealed flues should be provided with access to check that: The flue is continuous throughout its length Joints are correctly assembled and sealed There is adequate support Correct gradients and drain points are provided This is for visual inspection, not full physical access Access for inspection is already a requirement Regulation 27 of the Gas Safety Installation and Use Regulations 1998 16

Access to Concealed Flues Flue terminal External wall Flue terminal A new diagram (14) has been provided showing example locations for access hatches. Note that this diagram only covers horizontal flues, although the guidance also covers vertical flues. X Inspection hatch X Any intervening joints to be visible within 1.5 m of an inspection hatch X Inspection hatch X Accessible flue connection Boiler B Internal wall Inspection hatch X X Inspection hatch Any intervening joints to be visible within 1.5 m of an inspection hatch Boiler A Concealed flue connection All voids containing concealed flues should have at least one inspection hatch measuring at least 300 mm square. No flue joint within the void should be more than 1.5 m distant from the edge of the nearest inspection hatch i.e. dimension X in the diagram should be less than 1.5 m. Where possible inspection hatches should be located at changes of direction. Where this is not possible then bends should be viewable from both directions. 17

Access to Concealed Flues Flues should not pass through another dwelling, but may pass through accessible common areas Hatches should be at least 300mm x 300mm Voids containing horizontal flues should have at least one access hatch Hatches for horizontal flues should be within 1.5m of each joint Hatches for horizontal flues should be provided at each bend, or bends should be visible from both directions This access should not impair fire, acoustic or energy performance (Parts B, E and L of the Building Regulations) Note that this guidance applies regardless of the building type, fuel type or appliance output 18

Permanent Ventilation Openings Open-flued appliances require sufficient ventilation to avoid spillage of flue gases Previous guidance assumed a certain level of adventitious ventilation through gaps and cracks CO 2 Concentration (PPM) 800 600 400 Flue gas spillage This graph is indicative only Safe operation Ventilation rate 19

Permanent Ventilation Openings These days, we design and construct houses with: Low rates of air leakage (Part L) Adequate controllable ventilation (Part F) Permanent ventilation openings for combustion air for open-flued appliances (note that room-sealed gas and oil appliances do not need combustion air openings) There was concern that provisions for permanent ventilation openings in AD J 2002 were not sufficient for more airtight dwellings An important change to the Approved Document is an increase in the free area of permanent ventilation openings required for open flued appliances in modern airtight properties 20

New guidance has been added to sections 2, 3 & 4 for 2010: Air permeability is measured in m 3 /(h.m 2 )@50Pa The lower the air permeability, the more airtight Example below from section 3: Gas appliance in a room or space Permanent Ventilation Openings Air permeability <5.0m 3 /(h.m 2 )@50Pa: permanent opening 500mm 2 /kw Air permeability >5.0m 3 /(h.m 2 )@50Pa: permanent opening 500mm 2 /kw above 7 kw input (as in the old AD J) Ventilation opening free areas are now measured as equivalent area Similar changes have been made for oil and solid fuel appliances refer to the AD for more detail 21

Air Permeability of Older Dwellings New Appendix F for 2010 helps installers to assess whether the building is airtight Dwellings built after 2008 are likely to have documentary evidence of air permeability Older dwellings are unlikely to have an air permeability <5.0m 3 /(h.m 2 )@50Pa unless they have all or most of the following: Full double or triple glazing Draught seals on doors and windows Filled cavity or solid walls Careful sealing around loft hatch Etc. If in doubt, assume <5.0m 3 /(h.m 2 )@50Pa Further information in GPG 224 Improving Airtightness in Dwellings (free download from www.carbontrust.co.uk) 22

Hearths and Adjacent Walls New guidance has been added to section 2 for 2010 A hearth isolates an appliance from people, combustible parts of the building fabric and soft furnishings Hearths and adjacent walls should be made of non-combustible material Clearances are shown in diagrams such as these, which remain unchanged 23

Hearths and Adjacent Walls However the 2010 document allows clearances to be reduced to manufacturers recommendations for appliances with surface temperatures below 85 C where there is no risk of fuel or ash spillage This allows greater flexibility for modern appliances 24

Thatched Roofs A note has been added to section 2 for 2010 : Rigid twin-walled insulated metal flue liners in top-andbottom ventilated masonry chimneys are recommended Other types can be used, subject to risk assessment Spark arrestors are generally not recommended Further guidance in HETAS Information Paper 1/007 Chimneys in Thatched Properties 25

Revised guidance in section 2 Clarification of Outlet Clearances This was shown as a flat roof in the 2002 edition Where a flue serving a solid fuel appliance passes through the weather surface within 2300mm of an adjacent or adjoining building, it should be at least 600mm above any part of the building within 2300mm 26

European Chimney Designations Various locations in sections 1-4 refer to chimney designations In ADJ 2002, a brief description of chimney designations was given in paragraph 0.4(9) A supplement was issued in 2004 when the designation system changed from British to European standards For 2010, the key information from the supplement appears in a new Appendix G In addition, some of the temperature classes have changed (refer to the Approved Document for detail) 27

European Chimney Designations Chimney Number of Corresponding Chimney Standard Temperature Class Pressure Class N or P or H Resistance to Condensate Class, W (Wet) or D (Dry) Corrosion Resistance Class EN1234 T450 N2 D 1 G50 Sootfire Resistance Class G or O followed by distance to combustible materials 28

Requirement J6 states that: Secondary Containment for Oil Tanks Oil storage tanks and the pipes connecting them to combustion appliances shall be constructed so as to reduce to a reasonable level of risk of the oil escaping and causing pollution Requirement J6 applies only to fixed oil storage tanks with capacities of 3500 litres or less, and connecting pipes, which (a) are located outside the building; and (b) serve fixed combustion appliances (including incinerators) in a building used wholly or mainly as a private dwelling, but does not apply to buried systems. 29

Secondary Containment for Oil Tanks The normal means of providing secondary containment for domestic-scale oil tanks is double-walled tanks. CLG considered requiring secondary containment for all oil tanks, however this was rejected on cost grounds 30

Secondary Containment for Oil Tanks Where there is a significant risk of oil pollution, secondary containment should be provided. Section 5 lists locations where this is the case, including installations larger than 2500 litres, and installations within 50m of a source of potable water. For 2010, another has been added: Installations located within Zone 1 (inner protection zone) of an Environment Agency Groundwater Source Protection Zone (SPZ). The location of SPZs is shown on the Environment Agency s Groundwater Sources map available online at www.environment-agency.gov.uk/research/library/maps 31

Groundwater Source Protection Zones 32

Condensing Boilers CLG considered additional guidance on pluming from condensing boilers This was rejected as it is considered to be a potential nuisance issue rather than a health and safety issue Part J has always been strictly focused on health & safety However, notes have been added to sections 3 and 4 referencing the Guide to the Condensing Boiler Installation Assessment Procedure for dwellings (download from the Part L section of www.planningportal.gov.uk) 33

Conclusions The most significant changes are: Carbon Monoxide alarms for domestic solid fuel appliances Increased area of permanent ventilation openings for open flued appliances in airtight properties Access to concealed flues The old (2002) and new (2010) Approved Document J can both be downloaded from www.planningportal.gov.uk A presentation with audio can be viewed online at www.bsria.co.uk/news/partj-2010 34