R-GAGE QT50R-AFS Sensor

Similar documents
R-GAGE QT50R-AF2W Sensor

R-GAGE QT50R-AF2 Sensor

R-GAGE QT50R-AF2W Sensor

QT50RAF Radar-Based Sensor

R-GAGE Radar Sensor bannerengineering.com.

MINI-BEAM Expert Series

M12 Class 1 Laser Emitter

M12 Class 2 Laser Emitter

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

Ultrasonic Reflective Sensor

VX SERIES Wireless Thermostat with Occupancy Sensor

RK-05 Carbon Monoxide Detector Operator s Manual

CD6102 / CD6102 OC / CD6102-2

Ultrasonic Reflective Sensor

installation instructions Fan Tray System FTA-3/FTA-6

Remote Relay Module (RRM)

Quadrature Speed and Direction Sensors

TrueClean ToteCleaner

RK CO 2 Transmitter Operator s Manual

USER MANUAL SAVE THESE INSTRUCTIONS

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION LIGHT, WARNING, 360 DEGREE LED BEACON PUBLICATION

Original instructions Sense7-series Non-contact coded safety switch

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

RK Hydrogen Sulfide Transmitter Operator s Manual

Long-Range Barrier Sensors

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

CO2 Sensor User and Installation Guide

TAG MR VOLTAGE DETECTORS AND ACCESSORIES. Instruction & Operation Manual

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

RK-05 Combustible Gas Transmitter Operator s Manual

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

TrueClean ToteCleaner

RK Carbon Monoxide Transmitter Operator s Manual

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

SAVE THESE INSTRUCTIONS

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

M7100 Pressure Transducer

Murano Shower Cabin Installation Instruction

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

U5300 Industrial Pressure Transducer

Radio Frequency Do s & Don ts

Beacon 800 Gas Monitor Operator s Manual

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Blade Series Heat Exchanger Operation and Installation

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

Design Criteria. Installation

RK/ RK Oxygen Detector Operator s Manual

Indication & Pick-to-Light Solutions

M5200 Industrial Pressure Transducer

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

OWNERS MANUAL OPERATION GUIDE

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

GG-NH3-2% AMMONIA GAS SENSOR. Installation and Operation Manual

RK-05 Carbon Monoxide Transmitter Operator s Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

RK/ RK Oxygen Detector Operator s Manual

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

RK-02 Multi Point Detector Operator s Manual

INSTRUCTION MANUAL P Heating and 1 Cooling

Twin Photobeam Detectors Manual

WorkZone PreView Sensor Manual

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

Smart Home Outdoor Siren

RK-03 Hydrogen Detector Operator s Manual

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Port Machinery Sensing Solutions

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

M5800 Pressure Transducer with Rotatable Display

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description


ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

OPERATION, SERVICE & PARTS MANUAL

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

Solar Powered Wireless Photobeam Sensors

AUTO SPEED BLENDER INSTRUCTION MANUAL MODEL: BLCLMB1

OPERATION, SERVICE & PARTS MANUAL

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Sound Cover [ , , , ]

CT-7 Series Toxic Gas Transmitter Operator s Manual

48 TAYLOR CEILING FAN

K-Band Doppler Sensor Module

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

Fire-Water Bowls Model 100

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

Instruction Manual: IM E. Installation and Operation Manual for Powerware PVL 50, 80, 100, 120, 160, 200 KA

Transcription:

Datasheet Radar-Based Sensors for Detection of Moving and Stationary Targets FMCW (true-presence) radar detects moving and stationary objects Higher sensitivity and shorter range Adjustable sensing field ignores objects beyond setpoint Easy setup and configuration of range, sensitivity, and output with simple DIP switches Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air temperatures, or light Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication band Rugged IP67 housing withstands harsh environments Protected by US patents CAUTION: Make No Modifications to this Product Any modifications to this product not expressly approved by Banner Engineering could void the user's authority to operate the product. Contact Banner Engineering for more information. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Models Maximum Range Connection Supply Voltage Telecom Approval 2 Output Telecom approved for Europe, UK, QT50R-EU-AFS 5-wire 2 m 2 to 30V dc 3.75 m Australia, New Zealand, China, and Japan (6.5 ft) (2.3 ft) Integral cable QT50R-KR-AFS 2 to 2 V dc Telecom approved for South Korea Bipolar NPN/PNP DIP-switch-selectable N.O. or N.C. Cabled models only are listed. For integral 5-pin Euro-style (M2) quick-disconnect fitting, add suffix "Q" to the model number (for example, QT50R-xx-AFSQ). QD models require a mating cordset; see Quick Disconnect (QD) Cordsets on page 6. 2 For additional countries, contact Banner Engineering. Original Document 69603 Rev. E 7 August 206 69603

Overview The R-GAGE sensor emits a well-defined beam of high-frequency radio waves from an internal antenna. Some of this emitted energy is reflected back to the receiving antenna. Signal processing electronics determine the distance from the sensor to the object based on the time delay of the return signal. The sensor can be configured (via DIP switches) to sense objects up to a specific distance, ignoring objects beyond this distance (also called background suppression). Setpoint Figure 2. R-GAGE features D X Figure. R-GAGE setpoint Y. Power LED: Green (power ON) 2. Signal Strength LED: Red (flashes in proportion to the signal strength) 3. Output LEDs: Yellow (output energized); Red (configuration) Access the DIP switches behind the threaded cap on the sensor back (not shown) R-GAGE setpoint distances, minimum and maximum (sensor will detect objects up to setpoint and ignore objects beyond the setpoint) Description Distance X Minimum setpoint distance 2 m (6.6 ft) Y Maximum setpoint distance 3.75 m (2.3 ft) D Dead Zone 3 Sensor Configuration The sensing zone distance, sensitivity, and output configuration can be selected via the DIP switches on the back of the sensor. Use the included spanner to open the screw-off cover on the back of the sensor and access the DIP switches. Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight seal. DIP Switch Functions Switch Function, 2, 3 Sensing distance (detects objects from sensor face to this point), 5 Sensitivity (higher sensitivity sees weaker objects and has a larger beam pattern) 6 Normally open/normally closed output functionality 7, 8 Response Speed DIP switch is on the left and DIP switch 8 is on the right. 3 Typical dead zone: 0. m (.3 ft) for moving and.0 m (3.3 ft) for stationary targets, but varies with target reflectivity 2 www.bannerengineering.com - Tel: +-763-5-36 P/N 69603 Rev. E

Distance Settings Switch Switch 2 Switch 3 Distance 0 0 0 2 m (6.6 ft) 0 0 2.25 m (7. ft) 0 0 2.5 m (8.2 ft) 0 2.75 m (9.0 ft) * 0 * 0 * 3 m (9.8 ft) 0 3.25 m (0.7 ft) 0 3.5 m (.5 ft) 3.75 m (2.3 ft) Sensitivity Selection Switch Switch 5 Sensitivity 0* 0* (Highest) 0 3 (High) 0 2 (Medium) (Low) NOTE: Use the sensitivity selection to ignore unwanted weak reflections within the field of view, and not to narrow the beam width. Narrow-beam R-GAGE sensor models are available. Output Configuration Switch 6 NO/NC 0* NO NC Response Speed Switch 7 Switch 8 On (ms) Off (ms) Total (ms) 0 0 30 70 00 0* * 50 300 350 0 30 000 030 20 6000 620 P/N 69603 Rev. E www.bannerengineering.com - Tel: +-763-5-36 3

Specifications Range The sensor is able to detect a proper object (see Detectable Objects) from to 3.75 m (3.3 to 2.3 ft), depending on target Supply Voltage 2 to 30 V dc, less than 00 ma, exclusive of load For KR models: 2 to 2 V dc, less than 00 ma exclusive of load Detectable Objects Objects containing metal, water, or similar high-dielectric materials Operating Principle Frequency modulated continuous-wave (FMCW) radar Operating Frequency EU, KR Models: 2.050 2.250 GHz, ISM Band Maximum Output Power ERP: 3.3 mw, 5 dbm EIRP: 00 mw, 20 dbm Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-up Less than 2 seconds Output Configuration Bipolar NPN/PNP output, 50mA; DIP switch 6 selects N.O. (default) or N.C. operation Output Protection Protected against short circuit conditions Response Time DIP switches 7 & 8 select ON/OFF response time Indicators Power LED: Green (power ON) Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at x excess gain. Only indicates signal amplitude, not target distance. Output LEDs: Yellow (output energized) / Red (configuration) See Overview on page 2 Adjustments DIP-switch-configurable sensing distance, sensitivity, response time, and output configuration Construction Housing: ABS/polycarbonate Lightpipes: Acrylic Access Cap: Polyester Connections Integral 5-wire 2 m (6.5 ft) cable or M2 Euro-style QD fitting. QD models require a mating cordset Operating Temperature 0 C to +65 C ( 0 F to +9 F) Environmental Rating IEC IP67 Certifications ETSI/EN 300 0 CMIIT Category G ARIB STD T-73 KC mark - MSIP/RRA for others, contact Banner Engineering. Country of Origin: USA SRD2-IO3B200.2TR0. South Korea Class A Certification A 급기기 ( 업무용방송통신기자재 ) 이기기는업무용 (A 급 ) 으로전자파적합기기로서판매자또는사용자는이점을주의하시기바라며, 가정외의지역에서사용하는것을목적으로합니다. Dimensions 6. mm (.82") 38. mm (.50") 37.0 mm (.6") 7. mm (2.92") X Ø. mm (Ø 0.7") 33.0 mm (.30") 66.0 mm (2.60") 50.8 mm (2.00") 9.7 mm (0.78") R5.0 mm (R.77") 37.0 mm (.6") 3.2 mm (.35") M30 X.5 ISO-6g 50.8 mm (2.00") www.bannerengineering.com - Tel: +-763-5-36 P/N 69603 Rev. E

Beam Pattern Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m 2 ) Left-Right Beam Pattern Typical Beam Pattern (with different targets) at highest sensitivity level Left-Right Beam Pattern m m 2 m 2 m 0 0-2 m -2 m - m 0 2 m m 6 m 8 m - m 0 2 m m 6 m 8 m Distance Distance : Indicates sensitivity level : Weak Object (Radar cross section = 0.25 m 2 ) 2: Car (Radar cross section = 3 m 2 ) 3: Large Truck (Radar cross section = 50 m 2 ) : Passenger Train (Radar cross section = 300 m 2 ) NOTE: The effective beam pattern depends on the sensitivity level and target properties. Windows The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window. Polycarbonate at mm thickness performs well in most situations, but the performance depends on filler materials. Thinner ( to 3 mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the window. Locate the sensor in a position of minimum reflection from the window, which will repeat every 6. mm of distance between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 50 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance without issue. Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric boundary. P/N 69603 Rev. E www.bannerengineering.com - Tel: +-763-5-36 5

Wiring + 3 2-30V dc 2 Load Load 2 5 shield (QD cordset) Wiring Key: = Brown 2 = White 3 = Blue = Black 5 = Gray (Do not connect) NOTE: Banner recommends that the shield wire (QD cordsets only) be connected to earth ground or dc common. Shielded cordsets are recommended for all QD models. Accessories Quick Disconnect (QD) Cordsets 5-Pin Threaded M2/Euro-Style Cordsets with Shield Model Length Style Dimensions Pinout (Female) MQDEC2-506 MQDEC2-55.83 m (6 ft).57 m (5 ft) Typ. MQDEC2-530 MQDEC2-550 MQDEC2-506RA MQDEC2-55RA MQDEC2-530RA 9. m (30 ft) 5.2 m (50 ft).83 m (6 ft).57 m (5 ft) 9. m (30 ft) Straight Right-Angle 32 Typ. [.26"] M2 x 2 ø.5 3 5 30 Typ. [.8"] = Brown 2 = White 3 = Blue = Black 5 = Gray MQDEC2-550RA 5.2 m (50 ft) M2 x ø.5 [0.57"] NOTE: Pin 5 is not used. Mounting Brackets All measurements are in mm SMB30SC Swivel bracket with 30 mm mounting hole for sensor Black reinforced thermoplastic polyester Stainless steel mounting and swivel locking hardware included 58 29 67 A B SMB30MM 2-ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 30 mm sensor 57 70 A B C 57 Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 Hole center spacing: A = 5, A to B = 25. Hole size: A = 2.6 x 7, B = ø 6., C = ø 30. 6 www.bannerengineering.com - Tel: +-763-5-36 P/N 69603 Rev. E

Weather Deflector QT50RCK Required if the R-GAGE is exposed to rain or snow Prevents buildup of water or ice from interfering with sensor performance Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. For the most recent version of any documentation, refer to: www.bannerengineering.com. Banner Engineering Corp. All rights reserved