Dimensions. Model Number 123. Electrical connection. Features. Indicators/operating means. Product information RMS-G-RC-NA.

Similar documents
Dimensions. Model Number. Electrical connection. Features. Product information. Indicators/operating means RMS-G-RC. Radar sensor

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D-NA. Radar sensor

Dimensions. Electrical connection. Model Number. Features. Indicators/operating means. Product information RAVE-D. Radar sensor

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

FACTORY AUTOMATION HANDBUCH / MANUAL / MANUAL / MANUALE

1. LCD 2. radar antenna (narrow field) 3. radar antenna (wide field) 4. AIR-curtain width adjustment 5. AIR-lenses

Retroreflective sensor with polarization filter

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Retroreflective sensor with polarization filter

Sensing light curtain as per DIN 18650/EN 16005

SPACEMOTION SERIES SMM 01

Sensing light curtain as per DIN 18650/EN 16005

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

FlowJam Bulk Flow Detection

SWARCO TRAFFIC SYSTEMS GMBH. TDD1-MW Traffic Detector User Manual TDD1-MW_BE_00

Movement-based energy control

LZR -WIDESCAN OPENING, PRESENCE & SAFETY SENSOR FOR INDUSTRIAL DOORS

VL18LL-M/40a/118/128. VL18LL-M/40a/118/128. Fibre optic sensor for glass fibre optics. with M12, 4-pin metal connector

LZR -WIDESCAN. Motion, Presence, and Safety Sensor for Industrial Doors (US version) DESCRIPTION ENGLISH

MPAD-C 12-24V. Ceiling microwave presence/absence detector 12-24V AC/DC. Product Guide. Overview. Features

HANDBUCH / MANUAL / MANUEL / MANUALE TopScan-S

Download the BEA DECODER app for a quick overview of settings

Operating Instructions. Digital Radar Motion Detector With Infrared Remote Control MWD BF. Hörmann KG Verkaufsgesellschaft

MWS3 Ceiling Mount Microwave Occupancy Detector

LZR -H110. LASER SCANNER FOR BARRIERS & GATES with max. detection range of 5.0 m x 6.5 m (16.5 ft x21 ft) User s Guide

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

active infrared 875 nm < 250 mw/m² motion & presence 157 in x 157 in (emitting spots**) 2 in/s to activate detection 250 ms 15-45

FlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH

DDS-SSENSOR - INSTALLATION MANUAL. Installation Manual DDS-S SENSOR

Danfoss gas detection units

Ceiling Microwave presence/absence detector 12-24V AC/DC

Tri-level Control Sensor

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Danfoss gas detection units

Loop out. Ambient daylight threshold

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

>WIRELESS> ALARM SYSTEM CR200

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Oxygen (O2) Single-Point Gas Detection System

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

DDS-A / DDS-B HYBRID SENSOR

Original operating instructions Photoelectric safety sensors (safety light curtain / safety light grid) Protected area width (range) 0...

Orthos PIL-M02 SENSOR CONTROLLED ONE-WAY CORRIDORS

Download the BEA DECODER app for a quick overview of settings

Data sheet. Function description. Benefits

PHOTOELECTRIC AMPLIFIER SERIES

Product Specifications

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

Detector switch - Dual Tech SCS

ARCHITECTURAL DOOR HARDWARE SENSORS CATALOG

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

/ / 2018

Fire control panel detect 3004 plus and accessories

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

SISTEMA RFID CONECT 7.0

D-TECT Dual Tech. GJD360 Triple Technology External Detector

0 C to 50 C ( 32 F to 122 F ) 0% to 95% R.H. non-condensing. 30 to 95% R.H. Dry contact across terminal BI1, BI2 & UI3 to Scom

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

HGM1750 Automatic Generator Module OPERATING MANUAL Smartgen Electronics

K-Band Doppler Sensor Module

STANDARD FEATURES SPECIFICATIONS

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

English. Italiano. Português. Françias. Español

ANEMOMETER 4403-RF-BAT

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Two-Channel Gas Controller

User Manual 120/240/300 Outdoor Motion Detector

LZR -FLATSCAN SW SAFETY SENSOR FOR FULL- AND LOW-ENERGY AUTOMATIC SWING DOORS. Visit website for available languages of this document.

3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

D-TECT 3 IP. GJD260 IP Motion Detector

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EBDSPIR-PRM-LV Product Guide

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

English. Series. Installation and Use Manual

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

*** Quotation*** Joney Technology Co.,Ltd Wireless Control Panel/Detector/Accessories. CE RoHS APPROVAL PICTURE NEW

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

IP65 High Bay Dual Sense Sensor

SCS motion sensors Surface/wall mounting - PIR

R-GAGE QT50R-AFS Sensor

PD154 & PD158 VIGILANTE II ANNUNCIATORS Instruction Manual

FSTR- Series Microwave Motion Sensor (MSSD) Dimming Function/Detachable Version for LED Tri-proof Light & LED Batten. Introduction

TEC1100 Series Thermostats

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Wireless High Bay Sensor (WHS100) Installation Instructions

DESIGN EASY ADJUSTMENT

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

180 Degree Ceiling Mounted Occupancy Sensors

Viewguard Motion detctors PIR and DUAL detectors

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Transcription:

Dimensions ø.7 9.5 6.5 8.5 ø.7 65 57 Window for LED display Model Number Radar sensor Features Industrial gate opener with the ability to differentiate between people and vehicles Extra-wide detection area and long detection range Easily programmable Direction detection Version with FCC-frequency Electrical connection -pin terminal ~/0 V ~/+UB C NO -pin terminal C NO Programmable by remote control Product information The microprocessor-controlled microwave motion sensors based on the latest GHz technology provide a high degree of reliability even in difficult operating conditions and can be used with all automatic (industrial) doors up to a height of 7 m. The RMS-G sensors are equipped with intelligent functions, such as vehicle detection, to enable them to be used in a wide variety of applications. The special industrial door microwave sensor can be configured so that the industrial door only opens when a vehicle approaches it, while passing pedestrians are ignored. The sensor differentiates between people and vehicles. Indicators/operating means 5 6 7 8 IR receiver Antenna IR-transmitter Terminals (power supply/main relay) 5 Pushbutton / Menu 6 Pushbutton / Value 7 LED (red/green) 8 Terminals (vehicle relay)

Technical data General specifications Sensing range Function principle Detection speed Setting angle Operating frequency Operating mode Transmitter radiated power (EIRP) Functional safety related parameters MTTF d 60 a Mission Time (T M ) 0 a Diagnostic Coverage (DC) 0 % 7000x 6000 mm (DxW) at 5000 mm mounting height and 0 tilt angle 8000x 5000 mm (DxW) at 7000 mm mounting height and 0 tilt angle Microwave module min. 0. m/s 0... 0 in 5 increments.075....75 GHz K-Band Radar motion sensor < 0 dbm Indicators/operating means Function indicator LED red/green Control elements Programming push-button for selection of operating modes : Direction detection, Cross traffic suppression, Vehicle detection, Switching type Control elements Adjustment for off delay Control elements Programming via keys, alternative via remote control (Accessories ordered separately) Electrical specifications Operating voltage U B... 6 V DC,... 8 V AC No-load supply current I 0 50 ma at V DC Power consumption P 0 W Output Switching type NO/NC Signal output relay outputs Switching voltage max. 8 V AC / 8 V DC Switching current max. 0.5 A AC / A DC Switching power max. W / 60 VA De-energized delay t off 0.... 5 s adjustable Ambient conditions Operating temperature -0... 60 C (-... 0 F) Storage temperature -0... 70 C (-... 58 F) Relative humidity max. 90 % non-condensing Mechanical specifications Mounting height max. 7000 mm Degree of protection IP5 Connection plug-in screw terminals -pin and pin, 8 m connecting cable included with delivery Material Housing ABS, anthracite Mass 0 g Dimensions mm x 65 mm x 57 mm Suitable series Series RMS Compliance with standards and directives Standard conformity Functional principle FCC-Rules part 5 / This device can be used in North America. Use in countries within the European Union is not permitted. In other countries, all applicable national regulations must be observed. Microwave sensors are microwave scanners that use the principle of the Doppler radar. The most important requirement for microwave detection is that the object to be detected is moving. The microwave sensors emit microwaves of a defined frequency in order to detect people and large objects moving at speeds between 00 mm/sec. and 5 m/sec. The microwaves emitted by the emitter are reflected back from the ground or other surfaces to the receiver. If there is no motion in the monitored zone, the emitted and reflected frequencies are identical. Nothing is detected. If people, animals or objects are moving in the monitored zone, the reflected frequency changes and therefore triggers a detection. Based on the latest GHz technology with integrated microprocessor control, these sensors provide a high degree of reliability even in difficult operating conditions. The GHz frequency, known as the K-band, is reserved by CETECOM for this application area worldwide. The RMS-G series of sensors are equipped with intelligent functions to enable them to be used in a wide variety of applications. The cross-traffic suppression system can be configured so that the door only opens when vehicles or people approach it, while passing pedestrians are ignored. With direction detection, the opening impulse can be triggered based on the direction of motion. Depending on the setting, only movements towards or away from the sensor are Typical applications Opening impulse sensor for industrial doors Motion sensor for people and objects Activation sensors for detecting vehicles traveling at a maximum of 60 km/h (RMS- G-RC-HS) Detection area Accessories RMS Weather cap All-weather hood for RMS series microwave sensors, for ceiling and wall installation RMS Remote Control infrared remote control for series RMS RMS/RaDec Ceiling Kit wh Ceiling mount kit for radar sensors in the RMS and RaDec Series Other suitable accessories can be found at www.pepperl-fuchs.com

detected. settings The RMS-G-RC sensor is adjusted in programming mode directly on the device using two buttons: --> 8 = pushbutton/menu; 7 = button/value. The flashing sequence of the LEDs indicates the settings. With the RMS remote control, available as an accessory, the sensor can be easily and quickly programmed from the ground. The bidirectional infrared remote control with an LCD display and self-explanatory menu interface has a range of 0 m. Even sensors with considerable installation heights can be precisely and easily adjusted. Model number for remote control: RMS remote control 6 7 ) Antenna ) IR emitter diode ) IR receiver diode ) Screw terminal (vehicle relay) 5) Screw terminal (voltage/main relay) 6) LED indicator 7) Button/value 8) Button/menu The following properties are adjustable:. Dimensions of the sensing area 5 8 Mounting height 5 m Mounting height 7 m At maximum sensitivity and angle of incidence approx. 7 m approx. 8 m approx. 6 m approx. 5 m. Dimensions of the sensing area The size of the sensing area can be changed by adjusting the sensitivity using the buttons or remote control. High sensitivity = Large area. Position of the sensing area: The sensing area can be rotated in 5 increments from 0 to 0. The printed circuit board can also be inserted at an angle.. Detection without direction detection Forward/backward 0 Low sensitivity = small area 5 0

5. Detection with direction detection Forward (towards the sensor) Backward (away from the sensor) 6. Cross-traffic suppression Without suppression: door opens even in the event of cross-traffic With suppression: door remains closed in the event of cross-traffic 7. Detection of people/vehicles The sensor evaluates movements of people and vehicles in different ways and switches the main relay or both relays at the same time according to the setting. The distinguishing between people/vehicles makes it possible to only open the door for vehicles. Approaching people must use the side entry. 8. Relay functions The main relay always switches if it detects both people and vehicles. The vehicle relay only switches if vehicle detection is switched on and if a vehicle is detected and there is no pedestrian traffic. Function display LED LED green LED red LED quickly flashes green/red LED flashes green/red slowly LED flashes green LED flashes red Device ready for operation is activated is activated Initialization (for approx. 0 sec after switching on) Command received Fault Application examples: Distinguishes between people and vehicles Door with separate entry for people, door controller with entry, vehicle detection switched on, only vehicle relay connected The size of the sensing area can be changed by adjusting the sensitivity using the buttons or remote control. Vehicle approaching switches (LED quickly flashes red/green) The door opens Person approaching does not switch, door remains closed Person uses side entrance GATE CONTROL Door with no separate entry for people, door controller with two entries, vehicle detection switched on, main relay and vehicle relay connected Person approaching switches (LED lights up red) The door opens half-way Vehicle approaching and vehicle relay switch (LED quickly flashes green/red) Door opens fully

GATE CONTROL 5