CASSETTE UNIT. Comfort Circle

Similar documents
Cassette units Model Comfort Circle. - heating - cooling - ventilation

Optimal work climate with open doors. Industrial air curtains Model IndAC

INDUSTRIAL AIR CURTAIN. IndAC 2

Energy-efficient heat source provides comfort in large rooms

COLD STORE AIR CURTAIN MAT

Easily maintained air curtain. Comfort air curtains Model DoorFlow

DX AIR CURTAIN. SensAir

CHILLED ROOM AIR CURTAIN. IsolAir

The green and friendly entrance. Comfort air curtains Model CA 2

TopVent Design Handbook

CLIMATE SEPARATION SOLUTION. SensAir

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

NOZ2. Multi-Directional Heating & Cooling Solutions

COMFORT AIR CURTAIN. DoorFlow

VEX100 series Air handling units with cross-flow heat exchanger

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

Fan coil unit KL. Wall unit Ceiling unit

CHILLED BEAM CASSETTE IQ STAR LYRA

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Technical documentation Fan coil unit

WOLF WARM AIR CURTAIN

Metropolitan high output natural and powered trench heaters

Blower-YEFB-020-3R-1maxVel

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Recessed. Air Curtain. Fig 1. Recessed air curtain

QTS SELECTION TECHNICAL BOOKLET

CLIMATE SEPARATION SOLUTION. SensAir

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

INDUSTRIAL AIR CURTAIN. IndAC 2

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

AIR CURTAIN T SURFACE MOUNTED RANGE

technical data Fan coil unit FWB small duct unit

FAN COIL UNITS. The optimal solution for limited space

Polaris-I-60. active chilled beam. the future of space conditioning

The ventilation appliances

WOLF VENTILATION SYSTEM PRICE LIST

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Original instructions AR

FAN COIL UNITS LASER / LOW BODY / CONCEALED

TopVent. Recirculation Units and Supply Air Units for Heating and Cooling High Spaces.

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

QZHW Fan Coil Unit. Key features. Specifications

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Primo Hotel. General. Indoor climate units for hotel rooms

Technology for life. Unit heater LH

DOORS P -SERIES. Shop & Business MADE OFAIR. The smart way for Shop & Business TEDDINGTON AIR CURTAIN SYSTEMS FILTERLESS OPERATION

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

BRIZA EC 12 HYBRID. Low Water-Temperature system LOW TEMPERATURE SYSTEM / HEATING AND COOLING

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

UCS UCS/M UCS/H UCS900

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

energy efficient air curtains technical data and controllers

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Passive chilled beams

T-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Series VENTS VUT R WH ЕС

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

GEA Fan Coil Units Effective and quiet. Quality in detail GEA Cassette-Geko. Product Brochure

SIGMA PRISMA LOW BODY CONCEALED

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

NEW RANGE OF WARM AIR CURTAINS

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

Krantz. Multifunction exposed ceiling AVACS. Cooling and heating systems

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

RoofVent Design Handbook

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

PHV-RECESSED RANGE AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Manual Comfort Air Curtain

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

System architecture. Air treatment Index

HOTEL CHILLED BEAM IQ STAR SILENCIA

KLIMA Active Chilled Beams

Units for suspended cei lings

BTBa. FLUSHLINE Ventilated chilled beam for cooling, heating and ventilation. BTBa

iq Star LYRA II chilled beam cassette

Chilled Water DOAS Fan Powered Terminal Units

Regulations covering Heating and Ventilation equipment in Schools

PARAGON. Compact comfort module. Key figures

AIR CURTAINS. Air curtains with integrated control panel and remote control. Air curtains without heating, with electric heating or water heating

AC25. Art.nr:

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

Transcription:

CASSETTE UNIT Comfort Circle

Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool commercial offices and retail areas. A comfortable indoor climate creates a pleasant working environment for employees, and clients will naturally be inclined to stay for longer. For energy efficient heating and cooling in shops, supermarkets and offices, the space-saving Biddle cassette unit is the perfect candidate. Optimal indoor climate The Comfort Circle allows you to heat or cool the indoor space exactly as you wish, in a short period of time. For maximum comfort, the circular air discharge pattern ensures an even distribution of air throughout the room. Heating and cooling can be done separately, or combined within one unit. Using a combined unit has the advantage of reducing the number of installed units required. Space-saving and unobtrusive Climate equipment should preferably take up as little space as possible in your building. With the compact Comfort Circle, floor and wall surfaces remain available for shelves, racks and other furniture. The cassette unit is a recessed ceiling model and therefore meets this requirement. The unit can quickly and easily be installed in a suspended ceiling system; only the stylish circular air discharge grille is visible.

Comfort Circle cassette unit Benefits Optimal indoor climate - Outstanding climate control - Even air and temperature distribution - Heating and/or cooling in one unit Space-saving and unobtrusive - Integrated in suspended ceiling system - Stylish air discharge grille - Compact and low-noise Energy-saving and efficient - Suitable for lower water temperatures - Option to utilize residual waste heat - User-friendly and low maintenance And even more... - Several control options - User-friendly and low maintenance Water heating coil Energy-saving and efficient The Comfort Circle has been designed for use with a water based heating and cooling system. Nowadays, increasing emphasis is being placed on energy-efficient and sustainable climate units, which incorporate low water temperature ranges. This can be achieved, for instance, by utilising the waste heat of a cooling unit or heat pump. The Comfort Circle is compatible for use with this kind of system. It is also possible to deploy a cooling unit for heating; the so-called changeover system. For optimum coordination between the cassette unit and the heat and cold sources, an optional changeover sensor can be fitted. Complete climate concepts The unobtrusive appearance and low noise emission make the unit ideally suited for use in shops, offices, showrooms, reception areas, museums, banks and libraries.together with the automatic SensAir air curtain, the Comfort Circle forms a complete climate solution (for rooms with a maximum height of 4 metres). For ventilation, the Comfort Circle (ventilation model) can also be used in combination with the HR (heat recovery) unit.

Comfort Circle control A control option for every situation The cassette unit is perfectly suited for larger spaces such as shops and offices with a suspended ceiling. The ingenious 360 air discharge pattern ensures an evenly distributed temperature and air flow through the entire room, delivering maximum comfort with a very low energy consumption. Moreover, in commercial offices and retail areas quick and easy adjustment of the climate is essential, without any difficulties for the users. Therefore, Biddle s Comfort Circle comes with up to four different control options for an optimal, user-friendly solution for every situation. The client can set the desired room temperature via the control panel, quickly and easily bringing the indoor climate to the most comfortable level. Four control options 1. Basic unit without controller (B0) The cassette unit is equipped with a transformer and is wired by default at one fixed setting. 2. Fan speed controller (T0) The cassette unit is fitted with a fan speed controller that is compatible with external control systems, such as a building management system. The fan speed is then controlled externally (0-10 Volts or zero-voltage) 3. Thermostatic air-side Biddle control (S0/S1) This plug & play control regulates the fan speed (three speeds) to obtain the desired room temperature. The control can be delivered with a fixed (S0) or an auto-adjustable discharge angle (S1). 4. Modulating air and water-side Biddle control (M0/M1) The most comprehensive plug & play control for the cassette unit regulates both the fan speed and the discharge air temperature, to achieve precisely the desired temperature. This control can be delivered with a fixed (M0) or an auto-adjustable discharge angle (M1).

Comfort Circle control Well designed and user-friendly Both Biddle controls (thermostatic and modulating) are controlled by a well designed and user-friendly control panel. The control panel has various soft-touch keys and a handy LCD display. The desired room temperature is easily set via the control panel, after which time the control maintains the climate at the correct level. The keys can be locked with a 'key lock'. One control panel can be connected to and operate a maximum of ten units. The units are then linked together. The maximum length of the control cables in a control system is 100 metres. The control panel has various menus for several settings, such as use, installation, service and setting the week timer. Automatic or manual operation The control panel allows the user to choose between automatic or manual operation of the cassette unit. In the automatic mode, the correct fan speed is set on the basis of the temperature difference between the actual room temperature and the desired room temperature. Automatic on and off control The control panel features a week timer for switching the unit on and off automatically, each day of the week. Maximum convenience If you choose one of the two integrated Biddle controls, the units will be delivered completely ready to use: plug & play. For connection to the mains, the units are equipped with a fixed cable and a moulded plug. The control panel, any extra units and in and outputs can be connected via the connector plate and connections. Project specific modifications The Comfort Circle comes with three fixed tapping voltages (fans speeds) as factory default. By using a built-in transformer it is possible to adjust the standard speeds to the specific situation. Benefits - Four control options - User-friendly control panel - Automatic or manual operation - Plug & Play - Project specific

Comfort Circle technology Circular air discharge technology The bottom of the cassette unit consists of a panel with a circular air discharge grille. With recirculation units, the air intake and discharge take place via the same grille panel. The air is drawn in through the perforated pattern in the middle of the panel. After the air has been heated or cooled, it is blown evenly into the room across 360 via the air discharge openings on the side of the grille. The circular air discharge pattern generates an optimal and even air distribution, which ensures optimal penetration and air circulation even at low air speeds. Warm air is discharged at a fixed 45 angle towards the floor, to achieve good downward penetration of the air into the room (fig. 1). When cooling, cold air is discharged horizontally along the ceiling to create an optimal draught free climate. This Coanda effect (fig. 2) gives a better distribution of the cooled air throughout the room. Fig. 1: Heating Auto-adjustable ring The air discharge grille of units that can both heat and cool is fitted with a patented adjustable discharge ring. The unit adjusts the ring automatically and in doing so selects the air discharge angle that best fits the particular heating (fig. 1) or cooling (fig. 2). Consequently, the downward penetration and distribution of the air are always guaranteed. Fixed setting air discharge angle Units that either heat or cool only have a fixed setting for the discharge angle and do not have an adjustable ring. Fig. 2: Cooling

Comfort Circle possibilities A solution for every situation Selection The Comfort Circle is available in two models: CC 60: max. air flow is 740 m /h, suitable for heating rooms of 100 m2 CC 90: max. air flow is 1630 m 3/h, suitable for heating rooms of max. 200 m2 Specific criteria apply to cooling. This requires a cooling load calculation. The cassette unit is suitable for a maximum installation height of 4 m. 3 The Comfort Circle is suitable for recirculation and can either heat, cool, or do both. The circular air discharge pattern generates an even air distribution throughout the room. Air is extracted from the room via the small openings at the bottom of the unit. After the air has been heated or cooled, it is blown into the room at 360 via the air discharge openings on the side of the grille. Type code CC 60-H1C2-M1 CC = Comfort Circle Model size 60 = 60 x 60 recirculation 90 = 90 x 90 recirculation Coil type H2 = Hot water heating, 2-row H3 = Hot water heating, 3-row C2 = Cooling 2-row or change-over C3 = Cooling 3-row or change-over H1C2 = Heating 1-row, cooling 2-row Control B0 = Basic unit, excl. control, incl. trafo T0 = Fan speed controller S0 = Thermostatic airside control, excl. valve S1 = Thermostatic airside control with automatic angle adjustment, excl. valve M0 = Modulating air and waterside control, incl. valve M1 = Modulating air and waterside control with automatic angle adjustment, incl. valve Options Recessed ceiling model Ventilation model Free hanging model available Water heating Recirculation: heating and/or cooling Control options Basic unit without control (B0) Speed controller compatible with external controls (T0) Thermostatic air-side control (S0/S1) Modulating air and water-side control (M0/M1) Standard colours RAL 9016 Other RAL colours are available on request Ventilation model The cassette unit is available as a ventilation model, but only in combination with heat recovery, model HR. Information about the ventilation model is available on request. Heat recovery, Model HR

Comfort Circle delivery & accessories Delivery & accessories Various control and assembly accessories are available for the Comfort Circle. Standard delivery Two suspension brackets Two covering strips to adjust the air discharge pattern External condensation drain pump (for cooling) External condensation tray (for cooling) One or two water-side valves, fitted with actuators (only with modulating control) Control / operation If one of the two Biddle controls (S0/S1 or M0/M1) is used, these two accessories are always required: Control panel Low voltage cables (various lengths) Accessories Suspension set Change-over-sensor CC 90 adaptor plate to suit ceiling tile Smart suspension system Biddle cassette units can be installed either before or after fitting a suspended ceiling. The adjustable mounting system allows the unit to be moved in any direction. This means the unit can be positioned accurately, with minimal effort, and therefore easily integrated into the ceiling. Using an adaptor plate, the CC 90 is suitable for mounting in a suspended ceiling.

Comfort Circle specifications Specifications Comfort Circle (ventilation model) only in combination with heat recovery, model HR Casing The casing is made from zinc-plated sheet steel, additionally reinforced to minimise deformations and vibrations. The underside of the unit has a rotatable plastic air inlet and discharge grille. The casing is fitted with sound absorbing, heat insulating material. The complete unit is delivered as standard in the colour RAL 9016 (white). Other RAL colours are available at an additional charge. Fan / motor assembly The radial backward curved fans are mounted in the casing and cause no vibration. The fan is driven by an external rotor motor on ball bearings. The fan casing and the impeller are made from aluminium. The motor is manufactured in accordance with DIN 40050, protection category IP44 and insulation category B (CC 60) and F (CC 90). The motor is protected from overheating by thermal contacts, which will break the electrical circuit as soon as the maximum permissible motor temperature is exceeded (auto-reset). Heating /Cooling coil (LPHW / LPCW) The coil is manufactured with 3/8" copper tubes and aluminium fins. The coils are available in rows of 2 or 3. The operating pressure is max. 8 bar at max. 90 C. The diameter of the pipe work connections for coil type H1 is DN 15 (15 mm). For coil types H2, H3, C2 and C3 this is DN 20 (22 mm). The maximum water range of an H2 coil with: Thermostatic air-side control (S0/S1) = 80/60 C Modulating air and water-side control (M0/M1) = 90/70 C The maximum water range of an H3 coil with: Thermostatic air-side control (S0/S1) = 70/50 C Modulating air and water-side control (M0/M1) = 90/70 C The maximum permissible operating pressure is 8 bar at a water inlet temperature of max. 90 C. The maximum permissible discharge air temperature is 65 C. If a unit has to be connected to a water range with higher temperatures, please consult Biddle for advice.

Comfort Circle explanation of technical data Explanation of technical data Water flow rate When water and room temperatures other than the values represented in the tables are used, the water flow rate can be roughly calculated using the formula below. Before doing so, the heating or total cooling capacity must be recalculated based on the tables with correction factors. m = water flow rate [l/h] w Q = capacity [kw] C = specific heat of water (=4.18) [kj/kg C] pw ΔT = temperature difference water [ C] w ρ = density of water at 90 C (=0.984) [kg/l] w Water pressure drop When water temperatures other than the values represented in the tables are used, the water pressure drop can be calculated using this formula. To do so, the water flow rate must first be calculated (see above). Δ p = water pressure loss, table values [kpa] Δ p w 1 w 2 = water pressure loss [kpa] m = water flow rate, table values [l/h] w 1 m = water flow rate calculated using formula [l/h] w 2 Sound reference room In the tables, a sound pressure level in the reverberation sound field is given for all speeds. These sound pressure level values are based on the use of one unit in a reference room. The sound pressure in the room is determined dependent on the installation and the speed of the fan. The sound data are applicable to each unit and measured at a distance of 5 m from the unit. reference room unit volume room reverberation time CC 60 300 m3 0,5 s CC 90 600 m3 0,6 s

Comfort Circle explanation of technical data Sound in a deviating room and with multiple units If a unit is used in a deviating room, or if multiple devices are used in a single room, the sound pressure level must be recalculated. This can be done using the formula below. The relevant table value can be found in the tables (general data). L = sound pressure [db(a)] p T = reverberation time in deviating room [s] T = reverberation time [s] (see table) o V = volume deviating room [m ] V = volume reference room [m ] (see table) o n = number of units 3 3 Example calculation: what is the sound pressure level in the reverberation field when two CC 60 units at speed 2 are used in a room with a reverberation time of 0.7 sec and a volume of 600 m 3? Sound power level in db CC 60 speed sound power level sound pressure level per octave band in the medium frequency, in db (Hz) Lw db(a) 63 125 250 500 1000 2000 4000 8000 db(a) 1 37,6 44,6 54,4 50,5 45,7 44,8 44,5 29,2 16,3 50,5 2 47,1 47,6 62,1 59,4 55,3 55 53,7 46,8 34 60 3 52,1 50,9 65,7 64,2 60 60,3 57,4 53,4 41,3 65 CC 90 speed sound power level sound pressure level per octave band in the medium frequency, in db (Hz) Lw db(a) 63 125 250 500 1000 2000 4000 8000 db(a) 1 37,9 62,5 58,6 55,1 50,6 46,9 39,6 29,8 17,1 52,5 2 49,9 56,5 68 65,3 61,1 60,5 55,7 48,5 38,3 64,5 3 56,9 60,8 72 71,1 67,8 67,1 64,3 57,1 48,5 71,5

Comfort Circle correction factors Correction factors heating capacity The heating capacities shown in the tables for coil types H1 and H2 are based on a water range of 80/60 C. The heating capacity for coil type H3 is based on a water range of 60/40 C. In both cases an air inlet temperature of 20 C is assumed. With different water temperatures and/or air inlet temperatures, the heating capacity must be multiplied by the correction factors given below. Correction factors heating capacity coil types H1 and H2 CC H2/H1C2 water range air inlet temperature -10 C 0 C 10 C 15 C 18 C 20 C 90/70 C 1,95 1,69 1,44 1,33 1,26 1,21 82/71 C 1,87 1,61 1,37 1,25 1,18 1,14 80/60 C 1,72 1,47 1,23 1,11 1,05 1 70/50 C 1,5 1,25 1,01 0,9 0,83 0,79 60/40 C 1,27 1,03 0,8 0,68 0,62 0,57 50/40 C 1,17 0,93 0,71 0,6 0,53 0,49 50/30 C 1,04 0,8 0,58 0,46 0,39 0,35 Correction factors heating capacity coil type H3 CC H3 water range air inlet temperature -10 C 0 C 10 C 15 C 18 C 20 C 90/70 C 3,3 2,86 2,44 2,24 2,12 2,05 82/71 C 3,13 2,7 2,29 2,09 1,97 1,9 80/60 C 2,92 2,5 2,09 1,89 1,78 1,7 70/50 C 2,55 2,13 1,73 1,54 1,43 1,36 60/40 C 2,18 1,77 1,38 1,19 1,07 1 50/40 C 1,98 1,58 1,2 1,01 0,91 0,84 50/30 C 1,8 1,4 1,01 0,82 0,7 0,62

Comfort Circle correction factors Correction factors cooling capacity The cooling capacities shown in the tables for coil types C2 and C3 are based on a water range of 6/12 C and air inlet conditions of 27 C / 48% R.H. With different water temperatures and/or air inlet conditions, the cooling capacity must be multiplied by the correction factors given below. Data relating to other deviating refrigerants are available on request. Correction factors cooling capacity coil types C2 and C3 CC C2/C3 water range air inlet conditions relative humidity 40% 48% 50% 60% Qt Qs Qt Qs Qt Qs Qt Qs 6/12 C 22 C 0,56 0,75 0,58 0,74 0,59 0,73 0,7 0,7 23 C 0,61 0,81 0,65 0,79 0,67 0,78 0,81 0,75 24 C 0,66 0,87 0,72 0,84 0,75 0,84 0,93 0,81 27 C 0,86 1,03 1 1 1,05 1 1,29 0,98 28 C 0,94 1,08 1,11 1,06 1,16 1,05 1,42 1,03 8/14 C 22 C 0,47 0,62 0,47 0,62 0,47 0,62 0,53 0,59 23 C 0,52 0,69 0,52 0,68 0,53 0,68 0,62 0,65 24 C 0,56 0,75 0,58 0,74 0,6 0,73 0,72 0,7 27 C 0,72 0,93 0,81 0,89 0,85 0,89 1,07 0,86 28 C 0,79 0,98 0,91 0,95 0,96 0,94 1,2 0,92 10/16 C 22 C 0,37 0,5 0,37 0,5 0,37 0,5 0,38 0,49 23 C 0,42 0,56 0,42 0,56 0,42 0,56 0,45 0,54 24 C 0,47 0,63 0,47 0,63 0,47 0,63 0,53 0,59 27 C 0,61 0,81 0,65 0,79 0,67 0,78 0,84 0,75 28 C 0,66 0,87 0,73 0,84 0,76 0,84 0,97 0,8 12/18 C 22 C 0,28 0,37 0,28 0,37 0,28 0,37 0,28 0,37 23 C 0,33 0,43 0,33 0,43 0,33 0,43 0,33 0,43 24 C 0,37 0,5 0,37 0,5 0,37 0,5 0,38 0,49 27 C 0,52 0,69 0,52 0,69 0,53 0,68 0,63 0,64 28 C 0,56 0,75 0,58 0,74 0,6 0,73 0,74 0,7

Comfort Circle technical data Heating CC 60 Basic data CC 60 electrical supply V/ph/Hz 230/1/50 max. input current A 0,7 max. fan power W 143 tapping 1 2 3 4 5 6 7 8 9 10 11 tapping voltage V 60 70 80 90 100 115 130 155 170 190 230 air volume m³/h 120 150 190 230 270 350 430 550 620 680 740 sound pressure level at 5m db(a) 13 15 19 23 26 32 38 45 47 50 52 CC 60-H2 air inlet temperature C 20 weight kg 28 water range C 80/60 speed 1 2 3 air volume m³/h 430 620 740 heating capacity kw 6,4 8,5 9,7 discharge air temperature C 65 61 59 water flow rate l/h 280 370 425 water pressure drop kpa 2,1 3,5 4,6 water pressure drop with 3-port valve kpa 3,4 5,8 7,5 water pressure drop with 2-port valve kpa 3,4 5,8 7,5 CC 60-H3 air inlet temperature C 20 weight kg 31 water range C 60/40 speed 1 2 3 air volume m³/h 430 620 740 heating capacity kw 4,3 5,8 6,7 discharge air temperature C 50 48 47 water flow rate l/h 185 250 290 water pressure drop kpa 0,6 1,1 1,4 water pressure drop with 3-port valve kpa 1,2 2,1 2,8 water pressure drop with 2-port valve kpa 1,2 2,1 2,8 The unit is wired as standard on circuits 7, 9 and 11. This is speed 1, 2 and 3. The air inlet conditions are in compliance with Eurovent standards. The air discharge temperature of units with modulating control is limited to 50 C.

Comfort Circle technical data Heating CC 90 Basic data CC 90 electrical supply V/ph/Hz 230/1/50 max. input current A 1,2 max. fan power W 277 tapping 1 2 3 4 5 6 7 8 9 10 11 tapping voltage V 60 70 80 90 100 115 130 155 170 190 230 air volume m³/h 240 300 360 430 510 630 750 1040 1260 1490 1630 sound pressure level at 5m db(a) 24 23 25 28 29 34 38 45 50 54 57 CC 90-H2 air inlet temperature C 20 weight kg 49 water range C 80/60 speed 1 2 3 air volume m³/h 750 1260 1630 heating capacity kw 11,5 17 20,6 discharge air temperature C 65 60 58 water flow rate l/h 505 745 905 water pressure drop kpa 1,9 3,9 5,5 water pressure drop with 3-port valve kpa 3,5 7,4 10,6 water pressure drop with 2-port valve kpa 4 8,4 12,2 CC 90-H3 air inlet temperature C 20 weight kg 52 water range C 60/40 speed 1 2 3 air volume m³/h 750 1260 1630 heating capacity kw 8 12 14,7 discharge air temperature C 51 48 47 water flow rate l/h 345 520 635 water pressure drop kpa 0,5 1 1,4 water pressure drop with 3-port valve kpa 1,2 2,7 3,9 water pressure drop with 2-port valve kpa 1,4 3,2 4,7 The unit is wired as standard on circuits 7, 9 and 11. This is speed 1, 2 and 3. The air inlet conditions are in compliance with Eurovent standards. The air discharge temperature of units with modulating control is limited to 50 C.

Comfort Circle technical data Cooling CC 60 Basic data CC 60 electrical supply V/ph/Hz 230/1/50 max. input current A 0,7 max. fan power W 143 tapping 1 2 3 4 5 6 7 8 9 10 11 tapping voltage V 60 70 80 90 100 115 130 155 170 190 230 air volume m³/h 120 150 190 230 270 350 430 550 620 680 740 sound pressure level at 5m db(a) 13 15 19 23 26 32 38 45 47 50 52 CC 60-C2 air inlet conditions C/% 27/48 weight kg 29 water range C 6/12 speed 1 2 3 air volume m³/h 430 620 740 total cooling capacity kw 2,8 3,6 4,1 sensible cooling capacity kw 2 2,7 3,1 discharge air temperature C 13 14 14 condensate l/h 1,2 1,4 1,5 water flow rate l/h 405 520 590 water pressure drop kpa 5,3 8,4 10,5 water pressure drop with 3-port valve kpa 7,9 12,7 16 water pressure drop with 2-port valve kpa 7,9 12,7 16 CC 60-C3 air inlet conditions C/% 27/48 weight kg 32 water range C 6/12 speed 1 2 3 air volume m³/h 430 620 740 total cooling capacity kw 3,3 4,3 4,9 sensible cooling capacity kw 2,3 3,1 3,6 discharge air temperature C 11 12 12 condensate l/h 1,4 1,8 2 water flow rate l/h 470 615 705 water pressure drop kpa 4,1 6,7 8,6 water pressure drop with 3-port valve kpa 7,6 12,8 16,6 water pressure drop with 2-port valve kpa 7,6 12,8 16,6 The unit is wired as standard on circuits 7, 9 and 11. This is speed 1, 2 and 3. The air inlet conditions are in compliance with Eurovent standards.

Comfort Circle technical data Cooling CC 90 Basic data CC 90 electrical supply V/ph/Hz 230/1/50 max. input current A 1,2 max. fan power W 277 tapping 1 2 3 4 5 6 7 8 9 10 11 tapping voltage V 60 70 80 90 100 115 130 155 170 190 230 air volume m³/h 240 300 360 430 510 630 750 1040 1260 1490 1630 sound pressure level at 5m db(a) 24 23 25 28 29 34 38 45 50 54 57 CC 90-C2 air inlet conditions C/% 27/48 weight kg 50 water range C 6/12 speed 1 2 3 air volume m³/h 750 1260 1630 total cooling capacity kw 5,1 7,3 8,7 sensible cooling capacity kw 3,6 5,4 6,5 discharge air temperature C 12 14 15 condensate l/h 2,2 2,8 3,1 water flow rate l/h 735 1055 1245 water pressure drop kpa 4,7 9,1 12,4 water pressure drop with 3-port valve kpa 8,1 16 22,1 water pressure drop with 2-port valve kpa 9,1 18,1 25 CC 90-C3 air inlet conditions C/% 27/48 weight kg 53 water range C 6/12 speed 1 2 3 air volume m³/h 750 1260 1630 total cooling capacity kw 6,1 9,1 11 sensible cooling capacity kw 4,2 6,4 7,9 discharge air temperature C 10 11 12 condensate l/h 2,8 3,9 4,5 water flow rate l/h 875 1305 1575 water pressure drop kpa 3 6,2 8,8 water pressure drop with 3-port valve kpa 7,8 16,9 24,3 water pressure drop with 2-port valve kpa 9,3 20,1 29,1 The unit is wired as standard on circuits 7, 9 and 11. This is speed 1, 2 and 3. The air inlet conditions are in compliance with Eurovent standards.

Comfort Circle technical data Heating & Cooling CC 60 Basic data CC 60 electrical supply V/ph/Hz 230/1/50 max. input current A 0,7 max. fan power W 143 tapping 1 2 3 4 5 6 7 8 9 10 11 tapping voltage V 60 70 80 90 100 115 130 155 170 190 230 air volume m³/h 120 150 190 230 270 350 430 550 620 680 740 sound pressure level at 5m db(a) 13 15 19 23 26 32 38 45 47 50 52 Heating CC 60-H1C2 air inlet temperature C 20 weight kg 31 water range C 80/60 speed 1 2 3 air volume m³/h 430 620 740 heating capacity kw 3,1 3,9 4,4 discharge air temperature C 41 39 38 water flow rate l/h 135 170 195 water pressure drop kpa 0,7 1 1,3 water pressure drop with 3-port valve kpa 1,4 2,2 2,8 water pressure drop with 2-port valve kpa 2,5 4 5 Cooling CC 60-H1C2 air inlet conditions C/% 27/48 weight kg 32 water range C 6/12 speed 1 2 3 air volume m³/h 430 620 740 total cooling capacity kw 2,8 3,6 4,1 sensible cooling capacity kw 2 2,7 3,1 discharge air temperature C 13 14 14 condensate l/h 1,2 1,4 1,5 water flow rate l/h 405 520 590 water pressure drop kpa 5,3 8,4 10,5 water pressure drop with 3-port valve kpa 7,9 12,7 16 water pressure drop with 2-port valve kpa 7,9 12,7 16 The unit is wired as standard on circuits 7, 9 and 11. This is speed 1, 2 and 3. The air inlet conditions are in compliance with Eurovent standards. The air discharge temperature of units with modulating control is limited to 50 C.

Comfort Circle technical data Heating & Cooling CC 90 Basic data CC 90 electrical supply V/ph/Hz 230/1/50 max. input current A 1,2 max. fan power W 277 tapping 1 2 3 4 5 6 7 8 9 10 11 tapping voltage V 60 70 80 90 100 115 130 155 170 190 230 air volume m³/h 240 300 360 430 510 630 750 1040 1260 1490 1630 sound pressure level at 5m db(a) 24 23 25 28 29 34 38 45 50 54 57 Heating CC 90-H1C2 air inlet temperature C 20 weight kg 54 water range C 80/60 speed 1 2 3 air volume m³/h 750 1260 1630 heating capacity kw 6,2 8,7 10,4 discharge air temperature C 44 41 39 water flow rate l/h 270 385 455 water pressure drop kpa 2 3,9 5,3 water pressure drop with 3-port valve kpa 2,5 4,8 6,6 water pressure drop with 2-port valve kpa 2,6 5,1 7 Cooling CC 90-H1C2 air inlet conditions C/% 27/48 weight kg 53 water range C 6/12 speed 1 2 3 air volume m³/h 750 1260 1630 total cooling capacity kw 5,2 7,5 8,8 sensible cooling capacity kw 3,7 5,5 6,6 discharge air temperature C 12 14 15 condensate l/h 2,2 2,9 3,2 water flow rate l/h 745 1070 1265 water pressure drop kpa 4,9 9,5 13 water pressure drop with 3-port valve kpa 8,4 16,6 23 water pressure drop with 2-port valve kpa 9,4 18,8 26,1 The unit is wired as standard on circuits 7, 9 and 11. This is speed 1, 2 and 3. The air inlet conditions are in compliance with Eurovent standards. The air discharge temperature of units with modulating control is limited to 50 C.

CC 60 Comfort Circle dimensional sketches

CC 90 Comfort Circle dimensional sketches

Dimensional sketches Index The corresponding numbers in the dimensional sketches are explained below: 7 - Air vent 14 - Condensate discharge (only for cooling) 15 - Condensation pump (only for cooling) 16 - Condensation tray (only for cooling) 20 - Connection plate 23 - Cooling for 4-pipes H1C3 24 - Cooling or heating for 2-pipes 51 - Heating for 4-pipes H1C3 58 - Locking 64 - Return 78 - Slotted holes 81 - Supply 88 - Threaded rods (M8) are not supplied as a standard Explanation dimensional sketches All dimensions in mm A = detail waterconnections The diameter of the pipework connections for coil type H1 is DN 15 (15 mm). For coil types H2, H3, C2 and C3 this is DN 20 (22 mm).

Notes Notes

Biddle Air Systems Limited St. Mary s Road Warwickshire CV11 5AU Nuneaton Subject to change without prior notice T +44 24 7638 4233 E sales@biddle-air.co.uk I www.biddle-air.co.uk