SPECIALTY ROOM - Total Room Area: 14.3 m² / 154 ft² Basics A grooming room is set up to be able to do all beauty or grooming treatments in private luxury (pedicures, manicures, facials) Each room is equipped with a mandatory brand signature table that is multipurpose, hydraulic, four-legged and padded with built in foot sink and floor drain. Three feet of space [914mm] must be allowed around the table to allow effective treatments that are ergonomically healthy for therapists. All rooms must have sinks and counters equipped with locked cupboards, wall mounted towel warmers (or warming drawers). Hot towel cabinets are be built in to the millwork. Each room is individually adjustable for lighting (all dimmable); temperature and music. Air-flow is away from the treatment table. The head of the bed is best positioned towards the sink for easy access of the service provider. All equipment (facial trolleys, steamers, hot stones) needs to have hidden storage cupboard to be out of sight of guests. This room is also equipment with a t.v. with wireless headsets for guests to use during the treatment. The following illustrations depict a standard layout for this treatment room including the following data: standard layout, typical equipment to brand specifications, typical locations for electrical outlets and control switches and minimum space requirements. For details on equipment, refer to Equipment Specifications Book or www.willowstreamspastandards.com. Fairmont Raffles Hotels International Inc. Page 1 of 9
Fairmont Raffles Hotels International Inc. Page 2 of 9
EQUIPMENT SPECIFICATIONS ROOM Equip. # Image Description Electrical Outlet Plumbing Item # Installed By NFX-1 NFX-6 NFX-16 NFIX-20 NFX-25 Autoclave Sterilizer with one-step operation for sterilization of all utensils. All Purpose Golden Touch Package includes: Built-in pedicure tub with quiet pipeless jet system and ionizer, fully plumbed including drain. Includes plush 4" triple-wrap foam, round corners, hand control, Salon Headrest/Neck Support, Deluxe FaceSpace II w/pillow, Salon Footrest, and 60-degree elevating side arms. Shown with Contemporary style cabinet. Classic style also available. Oversized item ships by truck. This medium sized cabinet is designed to keep premoistened towels at a temperature of 158-176 F (70-80 C). 13 liter capacity Medical-grade oil warmer allows for countertop use or wall mount. Custom treatment trolley with wood veneer finish. Includes one drawer, one fixed shelf, rubber casters and power strip attached to rear of cart. 1500 Watts 2.5 Amps, 60 Watts. Motor: 24V DC Water pump: 12- volt DC centrifugal pump, 1.25 amp, w/110- volt/ 12-volt DC transformer 200 Watts 7 Watts 220V or 110V as 15 amps dedicated to unit Quad under table GFI protected and supplied from 120V AC, 15 amp circuit breaker to unit to Unit to unit None AM210006 Vendor (if 3/4" washing machine type hose bibs, drain feeds to 1-1/2" OD flexible hose to 1-1/2" floor drain. None None TA13960PK 's Contractor TJHC12 UV Vendor (if PL82-01-20 Vendor (if None CUFTT2 Vendor (if Fairmont Raffles Hotels International Inc. Page 3 of 9
Equip. # Image Description Electrical Outlet Plumbing Item # Installed By NFX-30 NFX-32 NFX-32a Technician Stool with height adjustable from 17"- 23" with backrest, lumbar support, and black base with 5 casters. Standard fabric color is white. Steamer with dynamic system (ozone). Integrated system for essential oils. Microprocessor-controlled. Pivoting arm (360 degrees). Base for steamer above. 24" High, 24" Wide. None None None ST13358 Vendor (if 700 Watts wall or base column None ST10140 Vendor (if None None None ST10150 Vendor (if NFX-42 Teflon coated, this wax heater is easy to clean and includes a built in thermostat for heat and temperature control. 220V or 110V as 60 Watts, E/F hybrid plug. outlet None PE921-12- 220V N/A FIX-20 Wall mount, high quality chrome complete with all hardware. Includes Wire kit. 220V. 100 Rated Watts Hard wired, Built-in GFCI None MYTEO130 's Contractor Fairmont Raffles Hotels International Inc. Page 4 of 9
GENERAL Dimensions: Minimum 11 [3.35m] x 14 [4.27m] (14.31m 2 ) Allow at least 3 ft. [.93m] of space on all sides of the treatment table Sound Separation: Sound proofing between rooms, water pipes, drains and doors. Sound separation STC 54 minimum for all walls. Doors: Solid core Silent closing devices Window: Locate on wall opposite from entry door where possible Sound proof Window Treatment: Obscure/covered (black-out) Wall: Standard dry wall construction Where possible, all finishes should be rated Green ; made from environmentally friendly materials. Semi-gloss or satin finish preferred in dry areas Flooring: Wood or carpet is acceptable, but must be easily cleaned and textures or color ranges should hide any minor spills. Tile is required under the table surrounding the drain but not visible t the guest. Ceiling: Fully enclosed (no drop ceilings) Fairmont Raffles Hotels International Inc. Page 5 of 9
A. MILLWORK: (refer to Spa & Fitness Typical Millwork/Joinery Drawings) Cabinets are lockable mastered (see room layouts) to store clean linen and supplies. Countertops are standard 35-36 [89-90 cm] high and have at least 5 linear feet [152 cm] of surface space. The surface is to be stain resistant, have a smooth surface and be easily cleaned. Hot towel cabinets should be placed on an open shelf in the upper cabinet. This space needs to be minimum of 2 6 wide (762), 1 3 high (381) and 1 2 deep (356) to fit the specified equipment. Must have electrical at shelf height. Custom trolley to match the millwork included All equipment must be able to be rolled into closet in millwork Fairmont Raffles Hotels International Inc. Page 6 of 9
B. EQUIPMENT (FIXED ONLY) Hand sink at counter is flush to countertop, with either lever handles or one handle temperature controls. Faucet is goose neck style at least 8 [20.32cm] height above sink top and should not splash or make noise when water is on. E.g. Stillness deck mount faucet K-956 from Kohler Towel warmer is hard wired hot towel warmer is required positioned on wall near door side or as positioned in drawings. Option to provide heated drawers in millwork for towels. Wall mounted flat screen t.v C. MECHANICAL ELECTRICAL PLUMPING (MEP) HVAC: Each room must have independently controlled HVAC unit with full temperature range. Supply grills and airflow are directed away from the tables. Slot vents are preferred and all intakes are hidden. Access panels are discretely placed - above the door or out the line of sight when guests enter. All heating and air conditioning vents must be silent and placed to avoid blowing on clients. Humidity Level: Low PLUMBING Drain: Sink waste at working counter Treatment table has a ¾ washing machine type hose bibs to feed a 1 ½ inch OD flexible hose to 1 ½ floor drain (see specifications of the treatment table) Fire Suppression: Per Code ELECTRICAL Power Electrical Outlets: Two 110v/220v 15 amps GFCI outlet at counter Fairmont Raffles Hotels International Inc. Page 7 of 9
Quad under table GFI protected and supplied from 120V AC, 15 amp circuit breaker, outlet recessed in floor under the center of the table. If monument is required, must be no higher than 2 )50.8mm) Two wall locations of 110v/220v 15 amps 12 AFF on wall opposite wall of counter and side wall away from door 110v/220v 15 amps GFCI outlet located behind the Hot Cabinet (either to far right or left side to allow or plug). TV Electrical and Cable for wall mounted t.v. at end of treatment room (for positioning see typical layout) See locations on sample layout. Lighting: All lights are dimmable and indirect. Two wall sconces minimum are provided One attractive ceiling mounted light over the table or cove lighting around the room One task light under cabinet over countertop. Place control for this light at countertop location. All controls are to be low tech and simple to operate adjacent to other controls at the door entry. Music: Control for selection of music of minimum of 8 channels from a central system with a volume control Speakers are of high quality, recessed in the ceiling. For sound system requirements refer to Section P of Design Standards Telephone: Not required D. OTHER Fixtures: Robe hook located behind arrival door Signage: Small number beside each door outside room (names are optional to add) Small dowel/hook under the number for hanging in use/not in use symbol Fairmont Raffles Hotels International Inc. Page 8 of 9
Local Code: Take into consideration all spa licensing requirements as well as zoning, building codes and permits, labor unions, fire safety codes, water, sewage, electrical code and ADA requirements as they relate to your area. Check all Local Department of Health, State Board and health and safety regulations. Fairmont Raffles Hotels International Inc. Page 9 of 9