Dry Desiccant Engineering Reference Guide

Similar documents
1.1 This section applies to air handling units for HVAC Systems.

TYPICAL CPA SPECIFICATIONS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION AIR HANDLING UNIT

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

Dry desiccant dehumidification systems. Product guide

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Modular Supply Make-Up Air Unit

AIR HANDLER SPECIFICATION

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

SECTION AIR COILS

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

XeteX, Inc. All Rights Reserved.

Direct Fired Heater Model AD Specification

AFD Industrial Dehumidifier Series

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

University of Delaware

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

FCC Fan-Coil Units High-Performance, Vertical

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Submittal Data Performance Data Electrical Data

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

Chilled Water DOAS Fan Powered Terminal Units

B. Unit shall be shipped as a single package unless the unit is too large to fit on a standard tractor-trailer.

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

SSL & SBS Engineering Guide

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Modular Heating & Ventilating Unit Model IGX-HV

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

AFD DEHUMIDIFIER SERIES

A. This Section includes air-handling units with coils for indoor installations.

Hood Depot Internatioonal, Inc., Phone S. Powerline Road, Deerfield Beach, FL

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Indirect Gas-Fired Make-Up Air

FAS Fresh Air Supply Units

Direct Fired Units w/ Packaged Cooling

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

A. Section includes factory-packaged units capable of supplying up to 100 percent outdoor air and providing cooling and heating.

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise T-Series AHU Full Spec. Prepared by: Phone Number: Prepared for: Acceptable Manufacturers

SECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS

MLR SERIES MODULAR AIR HANDLING UNITS

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

SECTION ROOFTOP REPLACEMENT AIR UNITS

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

A. Codes and Standards that are Standard at the University:

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

Air Handler Unit. Installation & Operations Manual. Table of Contents. Bulletin No. H-IM-AH August 2002 Part Number 4346B001

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

PRODUCT CATALOG BLOWER COILS.

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

SECTION CUSTOM INDOOR CENTRAL-STATION AIR-HANDLING UNITS For large systems, 50,000 cfm or more.

Direct Gas-Fired Make-Up Air

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Contents INDEX. TDM Series Indirect Fired Heaters

DRYAIR Turnkey Dry Room Standards

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

Catalog Destiny Indoor Air Handler. Models Horizontal Configuration. Vertical Configuration

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Direct Gas-Fired Make-Up Air Models DG and DGX

THE ULTIMATE ROOFTOP SOLUTION

SECTION (15820) - AIR DUCT ACCESSORIES

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Guide Specifications for InRow Direct Expansion

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

Energy Recovery with Cooling and Heating

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION CENTRAL HVAC EQUIPMENT

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

INSTALLATION INSTRUCTIONS TXV Coils EDM, EDD, EDA

DIVISION 15 MECHANICAL

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

SECTION FAN COIL UNITS

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Transcription:

Dry Desiccant Engineering Reference Guide Your Partner in Dehumidification 1

2

Table of Contents General Description...2 Operating Principle.... 3 Dehumidifier Module....4 uxiliary Module.5 Module Dimensions 6 Controls... 8 Sample Specifications...9 1

Kathabar Dehumidification Systems Kathabar Dehumidification Systems, Inc., the world leader in industrial humidity control, has manufactured dehumidification equipment for more than 75 years. The name "Kathabar," which is derived from Greek words meaning clean or pure air, describes what Kathabar equipment does best. The primary use of Kathabar is to provide precise and energy efficient air temperature and humidity control. Kathabar maintains the process or space at the required condition regardless of weather or process variations. Over the last 75 years, the design of Kathabar equipment has been continually evolving. dvances in heat/ mass transfer technology and construction materials have been incorporated. New product lines have been developed to serve the changing needs of industrial, institutional, and commercial users as well as to reflect changes in the cost and availability of energy. Energy cost and availability issues have resulted in the development of the Twin- Cel air-to-air enthalpy recovery system. Today, KDS offers you the unbiased choice between liquid and dry desiccant systems to best meet your needs. Kathabar KD Series The latest product of this design evolution, the Kathabar KD Series, is designed to provide additional benefits for dehumidification applications better suited to dry desiccant equipment. These benefits include the following: Simple, independent control of temperature and humidity Large range of airflow capacities up to 60,000 CFM Factory-integrated packaging capability Controls and automation integration to any desired level 2

HET SOURCE FIG. 1 KD System Schematic RECTIVTION IR + HOT IR MOISTURE-LDEN IR TO OUTSIDE COOL, DRY IR - WRM, DRY IR COOL, WET IR - PROCESS IR COOLNT SOURCE COOLNT SOURCE The KD dry desiccant systems operate on the principle of adsorption of water vapor from the air. The adsorbent (or desiccant) used is silica gel. The silica gel is formed on an inorganic substrate. The desiccant and substrate are arranged in a wheel-shaped rotor matrix having thousands of small, parallel air passages extending through its thickness. The desiccant rotor is housed in a cabinet that is separated into process and reactivation sections. In the process section the air to be dried passes through the rotor and the silica gel adsorbs some of the moisture from it. The dehumidifying process heats the air, so the air leaving the rotor is drier but warmer. To drive the adsorbed moisture out of the desiccant, the rotor slowly rotates into the reactivation section, where a second, heated airstream passes through the rotor. The hot air heats the Operating Principle 3 desiccant, driving the water out of it. The moisture-laden reactivation air is usually exhausted outside. The reactivated desiccant rotor rotates back into the process section to provide continuous drying of the process air. In many applications the process air is cooled before entering the desiccant rotor to enable the KD unit to produce dryer air. When precooling is needed, this cooling coil is usually included with the KD unit. ecause the process air is warmed while passing through the desiccant rotor, it may be too warm to suit the use requirements. If so, a final cooling coil is required, and is usually included with the KD unit. The reactivation airstream may be heated by electricity, steam, hot water or natural gas, depending on the application and available utilities. The air heating devices and its controls are usually included with the KD unit.

Dry Desiccant Dehumidifier Module Desiccant rotor made of inorganic substrate with silica gel desiccant formed in situ Unit housing of 14 and 16 gauge galvanized steel R-13 insulation standard, others optional Stainless steel inner liner optional 30% pleated air filters standard, with draft gauges Manual volume control dampers standard, for both process and reactivation Process and reactivation rotor draft gauges standard Electric, gas, steam, and hot water reactivation heaters available PLC-based controls with color touch-screen operator interface standard Unit base of welded structural channel Dry Desiccant Dehumidifier Package Combine dehumidifier module and auxiliary modules to meet your specific requirements Dimensional data for dehumidifier and auxiliary modules shown on pages 6 & 7 FIG. 2 3 8 5 6 4 5 6 4 3 2 7 7 4

1 Standard & Optional uxiliary Modules Housing (all) 6 Coil Materials Standard: 2 double wall, R-13 injected foam insulation, galvanized outside skin and frame, galvanized inner liner Standard: Option: luminum fins, copper tubes Copper fins, aluminum tubes, stainless steel Option: Stainless steel inner liner 2 Mixing ox 7 ypass Standard: Option: No dampers Dampers, actuators, hoods, stainless steel dampers Standard: Option: Mini bypass, with or without actuator Full face and bypass with actuators 3 Pre & Post Filters 8 Fans Standard: Option: 30%, 55%, 95% HEP filters Carbon filters, biocidal filters Standard: Option: DWDI fans Plug and plenum fans 4 Heating Coil 9 Packaged Refrigeration Standard: Steam, hot water Standard: DX package condensing unit Option: Gas, electric Option: Chilled water and ammonia package unit 5 Cooling Coil 10 Location Standard: Option: Chilled water, glycol, DX, ammonia CO 2 and all other exotic refrigerants Standard: Optional: Indoor rating Outdoor rating 5

Module Dimensions Use these module dimensions to estimate the overall size of your KD package. asic Dehumidifier Section UNIT SIZE DIMENSION (INCHES) 4500 64 75 70 6000 74 88 70 9000 82 95 70 12,000 90 102 68 C C C 16,000 100 112 68 20,000 116 124 70 Unit Size 12 Filters with 2 Pre-Filters 2 Roughing Filter Process Fan 4500 64 36 22 64 36 12 64 36 42 6000 74 42 22 74 42 12 74 42 46 9000 82 46 22 82 46 12 82 46 46 12,000 90 60 22 90 60 12 90 60 60 16,000 100 60 22 100 60 12 100 60 60 20,000 116 68 22 116 68 12 116 68 74 Minimum ase Height UNIT SIZE HEIGHT (INCHES) 4500 4 6000 4 9000 6 12,000 6 16,000 6 20,000 6 C 6

C C C C Unit Size Clg. / Htg. Coil with ccess Cooling / Heating Coil Sound ttenuator Face / Return 4500 64 36 48-54 64 36 18-24 64 36 40 64 36 12 6000 74 42 48-54 74 42 18-24 74 42 40 74 42 12 9000 82 46 48-54 82 46 18-24 82 46 40 82 46 12 12000 90 60 48-54 90 60 18-24 90 60 40 90 60 12 16000 100 60 48-54 100 60 18-24 100 60 40 100 60 12 20000 116 68 48-54 116 68 18-24 116 68 40 116 68 12 C C C C Unit Size Discharge/Return Plenum ccess - 24 Opening Fan Diffuser Mixing ox 4500 64 36 20 64 36 30 64 36 12 64 36 22 6000 74 42 22 74 42 30 74 42 16 74 42 24 9000 82 46 24 82 46 30 82 46 16 82 46 26 12,000 16,000 90 60 30 100 60 30 90 60 30 100 60 30 7 90 60 24 100 60 24 90 60 32 100 60 32 20,000 116 68 32 116 68 30 116 68 30 116 68 38

Dry Desiccant Controls Kathabar offers controls capabilities unique in the desiccant dehumidification market. The standard control system is based on a Koyo DL-06 series PLC and a Maple Systems Silver Series color touch screen HMI. PLC Options Include llen radley: MicroLogix SLC CompactLogix or ControLogix Square D Modicon Momentum G.E. Fanuc 90-30 Siemens 505 HMI Choices Include - PanelView CTC Powerstation utomation Direct E-ZTouch Standard Displayed Variables Operating status of: Process air fan Reactivation air fan Rotor drive motor Reactivation air inlet and discharge air temperature Reactivation heat percentage Optional Displayed Variables Outside air temperature and humidity Return air temperature and humidity Process air inlet temperature and humidity Process air discharge temperature and humidity Cooling coil discharge temperature and set point Cooling coil control valve percentage Heating coil discharge temperature and set point Heating coil control valve percentage ypass damper percentage Process air filter pressure drop Reactivation air filter pressure drop Rotor air pressure drop Fan VFD percentage KDS also offers communications interfaces for building or process control systems. Interfaces can be provided for: Ethernet Metasys Modbus Profibus DH+ communications protocols FIG. 3 Typical HMI Display 8

Dry Sample Specifications Scope Description Contractor to furnish and install a factory-assembled and tested desiccant-based air handling unit as described on the project drawings, equipment schedules and other documents. Provide all fans, filters, dampers and controls required for automatic operation of the desiccant air handling unit. Warranty The desiccant based air handling unit and its associated parts shall be warranted by the manufacturer against all defects in material and workmanship for a period of 18 months from shipment or 12 months from startup, whichever occurs first. Submittals Manufacturer shall provide detailed submittal drawings showing the arrangement of the unit with dimensions, electrical and utility connections and locations and performance data required to assure compliance with the plans and specifications. This shall include performance data for fans, coils, dampers, controls and all other major components of the desiccant air handling unit. t time of shipment, provide three (3) operating and maintenance manuals including a final set of drawings and spare parts lists. Factory-assembled Desiccant-based ir Handling Unit GENERL CONSTRUCTION: The air handling unit shall consist of a base, a desiccant dehumidifier module, and any other modules required to meet the plans and specifications. The desiccant dehumidifier modules and auxiliary modules shall be assembled to the base and to each other using mechanical fasteners. The integrated unit shall be suitable for [indoor] [outdoor] installation. UNIT SE: The base shall be made of welded structural steel channel sized for mid-length deflection of no more than 1/360 of the base length when the air handling unit is lifted from its ends. 9

DEHUMIDIFIER MODULE: The dehumidifier module housing shall be of welded construction using 14 and 16 gauge galvanized steel. Interior surfaces of the housing shall be insulated with closedcell flexible foam insulation having a minimum (R13) insulating value. The interior surfaces of the reactivation portions of the housing shall be insulated with minimum 2 thick rigid fiberglass insulation with aluminum foil facing. [The dehumidifier housing shall have an inner skin sheet of 20 gauge (galvanized) (stainless) steel.] The desiccant rotor shall consist of corrugated glass fiber media with silica gel desiccant formed in situ to form a monolithic structure. The media shall be contained in a segmented aluminum housing supported by a central shaft and bearings. The faces of the rotor shall be machined smooth for maximum seal life. The desiccant rotor shall be supported in a frame of welded stainless steel construction. The frame shall support a fractional horsepower gear motor to drive the rotor via a chain and sector sprockets attached to the perimeter of the rotor. The frame shall also support air seals to separate the process and reactivation airstreams. The seals shall be made of silicone rubber and designed for a life of 40,000 hours of continuous operation. The reactivation heat source shall be electric, gas, or steam as specified on the project drawings and schedules. The reactivation heat shall be of sufficient capacity to ensure the complete and continuous reactivation of the desiccant during summer or winter operation of the dehumidifier and to satisfy the design performance requirements. Electric heaters shall include a high temperature safety shutoff requiring a manual reset. The sensor shall be located between the heater section and the rotor inlet. fault light located on the operator s panel shall be signaled. [solid state relay] [SCR] proportional reactivation heater control system shall be provided in order to provide energy conservation. Direct fired gas reactivation shall include gas burner, combustion air blower, flame safeties, gas train with modulating gas valve, and the necessary controls to regulate the reactivation temperature as required and to comply with all applicable safety regulations. Steam heating coil shall be housed in an insulated enclosure to ensure maximum operation and personnel safety. Coil shall be the non-freeze steam distributing type mounted with stubbed connections. Coil to have single point connections for steam and condensate. Steam specialties such as control valves and traps shall be provided by the installing contractor [by the dehumidifier manufacturer]. The reactivation air inlet shall be provided with a side-access filter frame and [pleated 30% disposable] [cleanable metal 30%] filters. For units installed outdoors, the reactivation air inlet shall be provided with a weather hood and bird screen. The reactivation air fan shall be direct drive, single width, single inlet, and shall be provided with [a manual balancing damper] [a variable frequency drive] for controlling reactivation airflow. For units installed outdoors, a weather hood shall be provided for the fan discharge. 10

uxiliary Modules MODULE CONSTRUCTION: Modules shall be made with 16 gauge galvanized channel posts and panels secured with mechanical fasteners. ll panels, access doors, and ship sections shall be sealed with permanently applied bulb-type gasket. Shipped loose gasketing is not allowed. Panels and access doors shall be constructed as a 2-inch nominal thick; thermal break double wall assembly, injected with foam insulation for an R-value of not less than R- 13. The outer panel shall be constructed of G90 galvanized [G60 painted galvanized] steel. The inner liner shall be constructed of G90 galvanized [304 solid stainless] steel. Panel deflection shall not exceed L/240 ratio at 125% of design static pressure, maximum 5 inches of positive or negative static pressure. Deflection shall be measured at the midpoint of the panel height. The casing leakage rate shall not exceed 0.5 CFM per square foot of cabinet area at 5 static pressure. Module to module assembly shall be accomplished with an overlapping, full perimeter, insulated, internal splice joint sealed with bulb type gasketing on both mating modules to minimize on-site labor and meet indoor air quality standards. ccess doors shall be flush mounted to cabinetry [with inspection viewing window] with minimum of two six inch long stainless steel piano-type hinges, latch and full size (4.5 minimum) handle assembly. Door shall swing outward for unit sections under negative pressure (inward for unit sections under positive pressure). Doors limited from swinging inward (such as side access filter sections) on positive pressure sections, shall have a secondary latch to relieve pressure and prevent injury upon access. Coil drain pans shall be made from 304 stainless steel with cross break and double sloping pitch to drain connection. Supply/Return Fans Provide DWDI fan. Fan assemblies including fan, motor and sheaves shall be dynamically balanced by the manufacturer on all three planes and at all bearing supports. earings shall be self-aligning, grease lubricated, ball or roller bearings with extended copper lubrication lines to access side of unit. Fan and motor shall be mounted internally on a steel base. Provide access to motor, drive, and bearing through hinged access door. Fan and motor assembly shall be mounted on [rubber-in-shear] vibration isolators inside cabinetry. [Provide VFD for fan motor.] 11

Electrical and Control Wiring termination: provide terminal lugs to match branch circuit conductor quantities, sizes, and materials indicated. Enclose terminal lugs in terminal box sized to NFP 70. Provide [marine light] [marine light and GFI receptacle] in [fan] [each] section mounted and wired to a junction box and on-off switch mounted on the outside of the cabinet. Fan motors shall be 1800 rpm, open drip-proof (ODP). Motors shall be high efficiency to meet EPct requirements. Electrical characteristics shall be as shown in schedule. Electric and control panel cabinet shall be to NEM 12 [NEM 4] standards, factory mounted on the unit and shall include: UL or CS approved components Lockable fused disconnect switch Motor starters with contactors PLC controller with color touch screen operator interface Controls package as per specifications System run/fault indications Interconnecting wiring of components Cooling and Heating Coils Provide access to coils for service and cleaning. Enclose coil headers and return bends fully within unit casing. Unit shall be provided with coil connections that extend a minimum of 5 beyond unit casing for ease of connection. Coils shall be removable through side and/or top panels of unit without the need to remove and disassemble the entire section from the unit. WTER COILS: Certification acceptable water coils are to be certified in accordance with RI Standard 410 and bear the RI label. Coils exceeding the scope of the manufacturer s certification shall be acceptable provided the manufacturer is a current member of the RI certification programs and the coils are rated in accordance with standard 410. Headers shall be made of seamless copper tubing to assure compatibility with primary surface. Fins shall have a minimum thickness of 0.0075 of aluminum plate construction. Fins shall have full drawn collars to provide a continuous surface cover over the entire tube for maximum heat transfer. Tubes shall be mechanically expanded into the fins. Coil tubes shall be 5/8 inch seamless copper, 0.020 [0.025 ] [0.035 ] [0.049 ] nominal tube wall thickness, expanded into fins, brazed at joints. Soldered U-bends shall be provided having a minimum tube wall thickness of 0.025. Coil connections shall be O.D. sweat copper with connection size to be determined by manufacturer based upon the most efficient coil circuiting. Vent and drain fittings shall be furnished on the connections, exterior to the air handler. Coil casings shall be a formed channel frame of [galvanized steel] [304 stainless steel] 12

REFRIGERNT COILS: Certification acceptable refrigerant coils are to be certified in accordance with RI Standard 410 and bear the RI label. Coils exceeding the scope of the manufacturer s certification shall be acceptable provided the manufacturer is a current member of the RI certification programs and the coils are rated in accordance with standard 410. Coils designed for use with Refrigerant [R-22] [R-134a] [other]. Fins shall have a minimum thickness of 0.0075 of aluminum plate construction with full drawn collars to provide a continuous surface cover over the entire tube for maximum heat transfer. Tubes shall be mechanically expanded to the fins. Refrigerant coils shall be provided with round seamless 5/8 O.D. copper tubes on 1-1/2 centers staggered in the direction of airflow. ll joints shall be brazed. Sweat type copper suction connections shall be located at the bottom of the suction headers for gravity oil drainage. Coils shall be uniformly circuited in a counterflow manner. Pressure type liquid distributors used. Coils shall be tested with 315 pounds air pressure under warm water, and suitable for 250 psig working pressure. STEM COILS: Certification acceptable steam coils are to be certified in accordance with RI Standard 410 and bear the RI label. Coils exceeding the scope of the manufacturer s certification shall be acceptable provided the manufacturer is a current member of the RI certification programs and the coils are rated in accordance with standard 410. Fins shall have a minimum thickness of 0.0075 of aluminum with full drawn collars to provide a continuous surface cover over the entire tube for maximum heat transfer. Tubes shall be mechanically expanded to the fins. Steam coils shall be provided with round seamless 5/8 O.D. copper 0.020 [0.025 ] [0.035 ] [0.049 ] tubes. Tubes on two-row coils are staggered in the direction of airflow. ll joints shall be brazed. Steam coil headers shall be made of nonferrous materials using seamless copper tubing with intruded tube holes. oth the supply and return headers shall be completely encased by the coil casing. Coil shall be pitched in the unit to assure positive condensate drainage. Steam coils shall be furnished as uncased to allow for thermal movement and slide into a pitched track for drainage. Orificed baffle plates shall be installed in the supply connection to ensure proper diffusion of entering steam. Steam coils shall be tested with 315 pounds air pressure under warm water and suitable for 150 psig working pressures. Filters Filter section shall be furnished with filter racks and guides with hinged and latching access doors for side loading and removal of filters. Filter media shall be UL 900 listed, Class I or Class II. Prefilters shall be flat arrangement with 2 deep pleated panel filters rated at 30% dust spot efficiency. Two-stage filters shall be cartridge type arrangement with holding frames suitable for prefilters and final filter media and blank-off sheets, cartridge media filters with [60-65] [80-85] [90-95] percent dust spot efficiency. Cartridge filter media is 12 deep and housing is designed for side loading of filters. Filter section shall be supplied with minihelic gauge to read pressure drop across each filter bank for scheduling filter replacement. Gauge shall be recessed into the cabinet. 13

dditional Sections Mixing box section shall be provided with factory mounted low leak airfoil blade outside and return air dampers of galvanized steel in a galvanized frame. Dampers shall be hollow core airfoil blades, fully gasketed and have continuous vinyl seals between damper blades. [Outside air inlet shall be provided with weather louver] ccess section shall provide access between components and shall be a minimum of 30 [24 ]deep. ccess doors shall be made of galvanized steel for flush mounting, with gasket, latch and full size (minimum of 4.5 ) handle assembly. Diffuser section shall be mounted on leaving side of supply fan section providing uniform air distribution across downstream components. Perforated diffuser plate shall be secured over blast area of fan to disperse airflow. [Inlet] [Discharge] plenum section shall be provided as the [first] [last] section in the direction of airflow. The plenum shall provide single or multiple [top] [end] [bottom] openings. [Face and bypass] [ypass] section shall be provided to modulate airflow through and around the dehumidifier wheel. Dampers shall be an integral part of the unit assembly. Dampers shall be of low leak design, opposed blade, with vinyl bulb edging and stainless steel edge seals, galvanized steel frame, and axles in self-lubricating nylon bearings. Dampers DMPER LEKGE: Leakage rate shall be less than two tenths of one percent leakage at 2 inches static pressure differential. Leakage rate tested in accordance with MC Standard 500. Installation Contractor to install in accordance with plans and specifications and manufacturers recommendations. Unit manufacturer shall provide factory start up assistance in the field to make units fully operational and to train operating personnel. Installing contractor to contact manufacturer when installation is complete and ready for start up. 14

Notes 15

673 Ontario Street uffalo, NY 14207 1-888-9KTHR sales@kathabar.com / www.kathabar.com 16