CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE

Similar documents
CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER ANSWER SCHEDULE

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, JUNE 2015 LICENSED PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2017 TRADESMAN PLUMBER ANSWER SCHEDULE

REGISTRATION EXAMINATION, NOVEMBER 2016 CERTIFYING PLUMBER ANSWER SCHEDULE

APPENDIX L ALTERNATE PLUMBING SYSTEMS

Read Only Document Not For Distribution

Special Requirements For Health Care Facilities

REGISTRATION EXAMINATION, NOVEMBER 2014 LICENSED PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

PROPOSED NEW BUILDING

REGISTRATION EXAMINATION, NOVEMBER 2011 CERTIFYING PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

HOME INSPECTION CHECKLIST

2. Sanitary Plumbing General Installation Requirements

PLUMBING REQUIREMENTS

REGISTRATION EXAMINATION, JUNE 2013 CERTIFYING PLUMBER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

LABOUR RATES FOR PLUMBING CONTRACTORS. A guide to the labour costs of plumbing works LABOUR RATES FOR PLUMBING CONTRACTORS

STUDENT NOTES Plan, size and layout sanitary pipe work and fixtures

Water Supply (Water Fittings) Regulations 1999

Operation / Installation Manual

Building Utilities 1 Plumbing and Sanitary Systems

Read Only Document Not For Distribution

OWNER S GUIDE. Electric and Gas Storage Water Heaters. Safety Information Owner s Information Warranty. Models

Modular Grease Trap MGTA

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

REGISTRATION EXAMINATION, JUNE 2015 LICENSED GASFITTER ANSWER SCHEDULE

Frequently Asked Questions

Owner s Manual. Installation Details Owner s Information Warranty. 25L and 50L Electric Storage Water Heater

DOMESTIC & COMMERCIAL PLUMBING SYSTEMS FURTHER INFOMATION

CERTIFYING GASFITTER

MATERIALS Traps TRAPS. No. IPC IRC Description

-SQA- SCOTTISH QUALIFICATIONS AUTHORITY. Hanover House 24 Douglas Street GLASGOW G2 7NQ NATIONAL CERTIFICATE MODULE DESCRIPTOR

Australian/New Zealand Standard

Read Only Copy Not For Distribution. Chapter 10. Water Supply and Distribution 10.1 QUALITY OF WATER SUPPLY 10.2 RESERVED 10.

Compliance Document for New Zealand Building Code Clause G12 Water Supplies Third Edition

REGISTRATION EXAMINATION, NOVEMBER 2016 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CHAPTER VI BUILDING PLUMBING

Installing, modifying and maintaining domestic plumbing systems. Water Supply (Water Fittings) Regulations 1999

Greenleaf 600 Macerator Toilet Waste Pump

AIR ADMITTANCE VALVES FOR DOMESTIC PROPERTIES Guidance Notes

REGISTRATION EXAMINATION, JUNE 2012 LICENSED GASFITTER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Install Configurations

Plumbing Regulations 2018

Owner s Manual. Installation Details Owner s Information Warranty. Electric Storage Water Heaters

2016 Plumbing Supplemental Plan Review List

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

OWNER S MANUAL WARRANTY INFORMATION AND INSTALLATION INSTRUCTIONS PROFLO AND MARATHON ELECTRIC STORAGE WATER HEATERS

PLUMBING INSTALLATIONS

BUILDING OR RENOVATING? Jonathan Smith. The Plumbers, Gasfitters and Drainlayers Board (PGDB) says: ASK TO SEE THEIR CARD

The following test is Continuing Education for: Master Plumbers, Journeyman Plumbers, UDC Plumbing Inspectors, and Commercial Plumbing Inspectors.

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Pipe Sizing Table. Hydraulic Load Served (fixture units)

Level I Chapter 1 Worksheet

BACKFLOW PREVENTION GUIDE FOR COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL DEVELOPMENTS

1 WATERMARK CERTIFICATION SCHEME SCHEDULE OF PRODUCTS This document was adopted 1 August 2017 and replaced the WaterMark Schedule of Specifications

O Pro electric storage water heater

ENGINEERING STANDARD FOR SANITARY PIPEWORK ORIGINAL EDITION JAN. 1995

BBL Winterization Procedure

AS/NZS :2015. Plumbing and drainage AS/NZS :2015. Part 4: Heated water services. Australian/New Zealand Standard

Is Sewer Gas Giving Your Customers the Wrong Impression?

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

PRE-INSTALLATION GUIDE

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

Water Regulations Tutorial # 6 Conservation

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

Low pressure indoor copper cylinders

CMHC HOME MAINTENANCE CHECKLIST

Plumbing. Definitions. Background Factors. Air Chambers. Air Gap (Drainage System) Air Gap (Water Distribution System) Air Lock.

SECTION DOMESTIC WATER PIPING SPECIALTIES

1 Exam Prep Plumber s Handbook Tabs and Highlights

OWNER & INSTALLER MANUAL AND WARRANTY INFORMATION.

CENTRA-COIL QUALITY HOT WATER SERVICE

EVERLAST - SERIES 2000

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

Information Job Sheet 4. Closed-Loop Drainback Systems. Drainback tanks

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Inverted Bucket Steam Traps

Read Only Document Not For Distribution

SEALED THERMAL STORE

Dual Control Concealed & Exposed Thermostatic Shower Valve

Summary of Substantive Changes between the 2012 and 2018 editions of ASME A /CSA B125.1 Plumbing Supply Fittings

K4600 Assembly Directions

Methods of Venting Plumbing Fixtures and Traps in the 2018 IPC

House Drainage System. Building Utility & Services

Capri Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

CHAPTER 9 VENTS. run undiminished in size and as directly as possible from the building drain through to the open air above the roof.

Low pressure copper indoor cylinders

Dene Bath Shower Mixer

Matrix of changes for the National Standard Plumbing Code July 2013

Nero Tap Range. Fitting Instructions & Contents List

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

Macerator Pumps & Lifting Station. Technical presentation Part 1

Unvented Electric Water Heater 10/15 litre Undersink

Transcription:

No. 9195 CRAFTSMAN EXAMINATION, JUNE 2007 PLUMBING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers Board, 2007. All rights reserved. No part of this publication may be reproduced by any means without the prior permission of the Plumbers, Gasfitters and Drainlayers Board.

ANSWER 1 (a) Any SIX: The work of fixing or unfixing any sanitary fitting or appliance that is installed in any ship, aircraft or vehicle, or any plumbing work associated with any such sanitary fitting or appliance. The work of fixing or unfixing a gas, electrical, or solar water heater that supplies or is intended to supply hot water to not more than one sanitary fitting or appliance. The work of fixing or unfixing any other gas, electrical, or solar water heater in any case where fixing or unfixing of pipes supplying or intended to supply is not involved. The work of fixing or unfixing a bedpan washer, a bedpan steriliser, or a washing machine in any case where the fixing or unfixing of waste pipes or of pipes supplying or intended to supply water is not involved. The work of fixing or unfixing a pipe for reticulating hot water in any central heating system or a pipe supplying cold water from a tank or pressure reducing valve to a heating appliance used exclusively for a central heating system The work of fixing or unfixing any shower that is installed over a bath and that is supplied with water through the bath taps. The repair, or the replacement with a comparable heater, of any open-vented water storage heater using the same pipework but excluding any water storage heater connected to a solid-fuel heater or other supplementary heat exchanger, but only when the work (notwithstanding any notice issued under section 55 (1) of the Plumbers, Gasfitters and Drainlayers Act 1976) is done by a craftsman plumber, or by a registered plumber working under the direction of a craftsman plumber, or by the holder of a limited certificate working under the supervision of a craftsman plumber or registered plumber, or by any other person so authorised under section 53 of that Act. The repair, or replacement with a comparable fixture or appliance, of any sanitary fixture or sanitary appliance using the same pipework, but only when that work (notwithstanding any notice issued under section 55 (1) of the Plumbers, Gasfitters and Drainlayers Act 1976) is done by a craftsman plumber, or a registered plumber working under the direction of a craftsman plumber, or by the holder of a limited certificate working under the supervision of a craftsman plumber or registered plumber. The opening and reinstatement of any purpose-made access point within a drainage system that is deemed to be part of a building in accordance with section 3(3) of this Act. (b) 1 15 years (Any SIX, 1 mark each) (6 marks) 2 5 years 3 5 years clause or 15 years 4 15 years (or 50 years) 5 50 years 6 15 years (or 50 years) (½ mark each) (3 marks) Total 9 marks Craftsman Plumbing 9195 Answers, June 2007 1

ANSWER 2 Cause 1 Not Primed Prime Remedy or Action 2 Excessive Suction lift Reduce static suction lift, eliminate or reduce friction on suction side by use of larger pipes. 3 Air Leaks Check and eliminate air leaks by sealing, check glands. 4 Vapour lock Suction lift excessive for fluid temperature remedy one or other as appropriate. 5 Blockage Check for blockage in suction pipe foot valve or strainer. Check suction valves. 6 Deterioration (i.e. wear and tear) Check cylinder liner for wear, bucket leathers and valves. ANSWER 3 (1 mark each cause) (1 mark each remedy) (10 marks) Total 10 marks (a) Lower limit = 20kPa (2m head) Upper limit = 120kPa (12m head) (b) (i) A riser is a pipe installed vertically within a building as the continuation of the water main to supply water. (ii) (iii) (iv) A dry riser main is a vertical pipe within a building that contains no water and is available to be used by the fire brigade to pump water up through a building to hydrants and landing valves in times of a fire. A wet riser main is also a fire main and kept full of water at pressure for use in times of fire. A staging tank is a tank used in high-rise buildings to store water at different levels to give control of water pressure and to provide extra storage of water throughout the building. (1 mark each) (4 marks) Total 6 Marks Craftsman Plumbing 9195 Answers, June 2007 2

ANSWER 4 Q 2 25L = D 5 H D 5 = Q 2 x 25L H Q = 575 60 = 9.583 L/s Diameter = 5 9.583 x 9.583 x 25 x 420 90 = 5 964255.835 90 = 5 10713.954 = 6.397 cm = 63.97 mm (65 mm pipe required) (6 marks) Total 6 marks ANSWER 5 (a) The chamber housing the back-flow device must be watertight in that all precautions must be taken to ensure there is no ingress of water. The chamber must be provided with an appropriate drain or pump system (so that the device is never submerged). The discharge port of the relief valve must be 300mm above the floor of the chamber. To enable a continuous 24 hour a day water supply, a fully protected bypass complete with a reduced pressure zone device will need to be installed in parallel to allow for repairs, testing or replacement. The chamber must be large enough to allow easy access for replacement, repairs and testing. The back-flow devices must be supported independently of pipework. (1 mark each for any FIVE) (5 marks) Craftsman Plumbing 9195 Answers, June 2007 3

(b) A Dual Check Valve (which does not incorporate any test points) A Dual Check Valve with atmospheric vent (which does not incorporate any test points.) A vented double check valve. Atmospheric vacuum breaker Hose connection vacuum breaker. (1 mark each for any FOUR) (4 marks) (c) 1 As near as practical to the potential source of contamination. 2 In an accessible position to enable maintenance and inspection. (d) 1 An assembly of at least two independently operating force-loaded check valves. 2 Sufficient test points to allow each valve to be independently and regularly tested. (e) Any ONE: Immediately upstream of the toxic fertiliser injector. On the branch to the irrigation system. (f) 1 Pressure type vacuum breaker 2 Atmospheric vacuum breaker Check answer against G12 and AS3500 Total 16 marks Craftsman Plumbing 9195 Answers, June 2007 4

ANSWER 6 Safe trays Seismic restraints Tempering valve Valving Cold supply to shower Cylinder Drain Venting Safe tray drains (1mark) Total 12 Marks Craftsman Plumbing 9195 Answers, June 2007 5

ANSWER 7 The storage unit The wet back heat exchanger The recommended heights between the storage cylinder and the wet-back Pipework including grades Correct venting Lagging requirements (flow 1 mark, return 1 mark) (½ mark each, 1 mark) No valves or obstructions shall be installed in the piping (primary and return) between the heat source and the storage tank zero marks awarded if this is done. Total 7 marks Craftsman Plumbing 9195 Answers, June 2007 6

ANSWER 8 A free outlet storage water heater has an open outlet from the top of the cylinder to the discharge point (usually a sink). Cold water is allowed to flow into the bottom of the cylinder displacing hot water out through the free outlet discharge point. The free outlet is used as the expansion pipe and vent for the system in case of malfunction with the thermostat. The inlet must be restricted to be smaller than the outlet. (5 marks) Total 5 marks Answer 9 (a) (b) The discharge pipe of a Bidet shall be directly connected to a drain or soil pipe, or may discharge as a waste pipe to a gully trap. Backflow protection must be incorporated either by air gap at a supply tank or RPZ backflow device. (c) 32 mm diameter (d) 1 unit (e) The vent may be omitted when the waste discharges under a gully grate and that waste is less than 3.5m in length or when it is the top fitting on a soil stack and is less than 3.5m in length. Total 8 marks Answer 10 (a) Any FOUR: Convey foul water from the building to a foul water drainage system Avoid blockages. Avoid leakages. Prevent foul air and gases from entering the building. Enable access for maintenance and clearing of blockages. Avoid undue noise. (Any FOUR ½ mark each) Craftsman Plumbing 9195 Answers, June 2007 7

(b) Any three: The system must always have one open vent to atmosphere. They must be located in an accessible position. No smaller than the diameter of the vent pipe that it serves. Where the valve is unlikely to become frozen. Where it is protected from damage. (c) (d) Where adequate air can enter the valve. The purpose of an untrapped floor waste is to provide for accidental spillage or overflow from sanitary fixtures or appliances. Any three: The floor waste pipe must discharge to the outside of the building to the open air. (3 marks) The floor waste pipe should terminate with a suitable vermin-proof flap or grill to prevent the passage of rodents. Discharge to safe location. Must have removable grating. (Any three) (3 marks) Total 10 marks Craftsman Plumbing 9195 Answers, June 2007 8

Answer 11 MULTI CHOICE 1 d 2 a 3 a 4 e 5 b 6 b 7 c (Marking schedule 1 mark for each correct answer) (7 marks) Total 7 marks Answer 12 True length = 4.500 2 + 1.170 2 = 4.500 x 4.500 + 1.170 x 1.170 = 20.250 + 1.370 = 21.620 = 4.650 m Add overhang 4.650 + 0.065 = 4.715 m (or 4715 mm) (4 marks) Total 4 marks Craftsman Plumbing 9195 Answers, June 2007 9