Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Similar documents
Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION

configurable safety and programmable logic SLATE Integrated Combustion Equipment Management The revolutionary integration of

Thermal Solutions ENGINEERED TO ORDER. End-to-end solutions and services to meet your thermal process requirements

Powerful intelligence. Breakthrough functionality. SV2 Series Intelligent Safety Shut-off Valve

Honeywell SLATE ICM Platform

SLATE. Integrated Combustion Equipment Management Success Stories

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Distributed By: M&M Control Service, Inc Building Technologies

DIVISION FINNED WATER-TUBE BOILERS

Honeywell Thermal Solutions. COMPREHENSIVE SOLUTIONS for the most complex combustion applications.

Revitalize Building Mechanical Systems (4619)

Engineered Systems. Complete combustion solutions that enable you to MAXIMIZE YOUR BUSINESS OPPORTUNITIES

DIVISION FINNED WATER-TUBE BOILERS

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Complete burner management in a compact, affordable system

Power Flame Incorporated

Thermal Solutions. COMPREHENSIVE SOLUTIONS For the most complex thermal process applications

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

CONTROL SYSTEMS Combustion Control Burner Management Control Balance of Plant Equipment Control Supervisory Control and Data Acquisition

Complete Boiler Management in a Compact, Affordable System

Complete burner management in a compact, affordable system

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Energy recovery from exhaust gases using Heat Pipe technology

DELTA-TE III. Nozzle-mix line burner

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

FINNED WATER-TUBE POOL HEATERS

Energy saving and better heat control.

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Originators of the Flexible Water Tube design

HEADLINE LOREM IPSUM COMPANY EFFICIENCY

Originators of the Flexible Water Tube design

HCLEARFIRE. High-efficiency, modular steam boiler HP

Improving the Performance of Power Plants Worldwide

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

Desiccant Air Dryers. ABP Series. Blower Purge Desiccant Air Dryer 70-8,000 scfm

INDITHERM. Low temperature gas burners

INDUSTRIAL WATERTUBE BOILERS

Controllers, Indicators & Set Point Programmers

Domestic Hot Water Heaters and Boilers FTIIIC-6

FTIIIC-10. Domestic Hot Water Heaters and Boilers

DIVISION FINNED WATER-TUBE WATER HEATERS

WATER-TUBE POOL HEATERS

STEAMPAK Series BurnerPAK BMS Burner Management Systems

WATER-TUBE POOL HEATERS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Originators of the Flexible Water Tube design

Triton Series High Efficiency Boiler

FXLF-4. High Efficiency Water Heaters and Boilers

DIVISION FINNED WATER-TUBE WATER HEATERS

Suggested Specifications Prestige Excellence 110

A New Standard of Excellence

Dependable Solutions for Gas Detection

FINNED WATER-TUBE POOL HEATERS

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Power Flame Incorporated

Model D12-IR. Digital Gas Transmitter...

HIGH EFFICIENCY COMMERCIAL BOILERS

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

B-40/B-41 Modulating Temperature Controller

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

INDITHERM. Low temperature gas burners

"NP" & "RG" AIRFLO. In-duct firing line burner

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Bosch Uni 7000F Cast Iron Hot Water Boiler

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

Boiler Basics. Design and operation

Natural Gas Savings in Industry

FXLF-9. High Efficiency Water Heaters and Boilers

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

CONDENSING HIGH EFFICIENCY BOILERS

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

Series LV AIRFLO. In-duct firing line burner

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Cabinet Cooler Systems

For Complete Fire and Gas Solutions

Flame Monitors BROCHURE

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SECTION PACKAGED HEAT TRANSFER SYSTEM

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Autocalibration Systems for In Situ Oxygen Analyzers

COMPACT FLAME CONTROLLER CFC 2000

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

C1210ES Tankless Water Heater

Dräger Flame 2500 Flame Detection

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

Transcription:

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

Honeywell Thermal Solutions Family of Offerings: 1 Product Brands: Becomes Becomes Becomes Hauck Exothermics Combustion Safety* *From CEC Combustion Safety to Honeywell Combustion Safety Completed The Honeywell Thermal Solutions family of offerings includes: To Come Honeywell Combustion Safety and Services, Eclipse, Exothermics, Hauck, Kromschröder, and Maxon http://thermalsolutions.honeywell.com/

Thermal Solution 2 Burner Management System Exhaust Flue Emissions: NOx, SOx, CO Heat Recovery Heat Transfer Via: Direct Convection & Radiation OR Indirect Convection & Radiation Oxygen Source Air Oxy-Rich Air Pure Oxygen Fuel Train Oil Gas Burner Product 2015 by Honeywell International Inc. All rights reserved.

Honeywell Thermal Solutions Markets 11 Textile Automotive Paper Food Metal Burner packages for textile dryers tenter frames and predryers Burner systems for paint applications Complete burner systems for paper dryers Spray dryers Coffee Roasters Baking ovens Counterflow dryers Metal melting Thermal treatment Ladle preheaters Printing Glass Chemical Construction Ceramics Burner packages for industrial printing machines High temperature oxy fuel burners for glass melting ovens Process air heaters Thermal oxidizers Insulation fabrication Bake ovens for bricks Sand dryers Ceramics furnaces Power generation Environmental Heat Recovery Steam Generation Power Plants Waste incinerators and flue gas treatment Serving a broad range of markets and applications

4 Industrial Flame Monitoring(IFM)

Industrial Flame Monitoring 5 Honeywell's Industrial Flame Monitoring systems are suitable for high level flame monitoring with a high level of discrimination for : - industrial boilers, kilns, Claus reactors, thermal oxidizers, gas turbines, multiple burner boilers, and with multiple fuels (oil, gas, and coal)

Industrial Flame Monitoring with the Ability to see the Selected Target Flame Only Through Tuning 6 Dual UV & IR Sensors Single UV or IR Sensors Triple UV, UVSS, & IR Sensors Flare Monitoring UV Sensors

Industrial Flame Monitoring Tuning Capabilities 7

8 Maxon Valves

Industrial SSOV s - Key Features 9 Hazardous locations, SIL-3, global certifications Wide range of configuration options for industry Bodies built of one-piece cast iron, cast steel or stainless steel for heavy duty industrial service - Handles corrosive gas, O2, oil, liquid, general purpose applications - Unique bonnet design eliminates packing adjustments, reducing maintenance and minimizing drag on closing - Field rotatable top assemblies in 90 increments to fit specific application requirements. Unique metal-to-metal shut off valve mechanism - Sliding Gate (Rising Stem) shut-off micro-lapped seating wears in, not out - Meets FCI 70-2 control valve standard for Class VI seat leakage - Provides a complete, tight seal that that does not rely on soft seals (that tends to wear out with repeated movement)

Series 8000 Pneumatic SSOV 10 Pneumatically actuated valves with powerful closing spring - Provides closure in less than 1 second for reliable, long-life operation Unique vertical space saving design - Offered in ¾ 8 sizes - Materials- cast iron, carbon steel, low temperature carbon steel, stainless steel - Trim options for clean and corrosive gas, oxygen, and liquids - Rated for low temperature service to -50ºC (-58ºF) - Fire-safe exposing the valve to flame temperatures of 760º- 980ºC Large top mounted open/shut indicator for highly visible valve open/close status PED (pressure equipment directive)- Certification for EMEA compliance Non-Destructive Engineering (NDE) testing available Redundant external solenoid available, certified for SIL3 compliant systems Available with PSCheck partial stroke testing

Smartlink DS Control Valve 11 Control actuator for air, fuel, gas, steam, chemicals and liquids for industrial combustion applications Rated torque of 300 in-lbs and 900 in-lbs Highly precise control of air/fuel accurate to 0.1 (100⁰ span) Direct 4-20mA / Modbus control interface AC and DC versions available Offered with a wide range of integrated ball and butterfly valves Non-incendive for C1-D2 hazardous location NEMA 4, 4X (IP66) weatherproof enclosure Approved for ATEX/IEC Zone 2 Wide Temperature Range -40 F to +158 F (-40 C to +70 C) Display (optional) Optional 2-line LCD To commission, review alarms, status, and health reporting Backlit for viewing in dark installations Alternate Programming Options Modbus communications to PLC, Modbus direct to the DCS, program direct from a laptop via RS-485 Works with SLATE systems

12 SLATE

SLATE 13 What s inside? - 24 VDC or 24 VAC to 240 VAC Burner Management in a modular format - Configurable Safety and Programmable Logic - Fuel Air Ratio Control with 4 actuator channels and 2 VFDs - Wide range of torque sized actuators - Trim (O2, any trim!) - Flexible fuel air curve setup - Dual fuels capability - Universal I/O (Analog and Digital) - Modbus, BACnet, and web services communications - UL353 Limit - First out annunciation for faster troubleshooting - Color touch screen display with rich graphics potential - 7800 Emulation Tool Approvals - CE - UL and FM - ISO 233552-1 for Fuel Air Systems in Canada Completed - SIL3 Q3 2016

SLATE Solves Problems 114 Provide greater energy efficiency - Parallel Positioning and Trim (O2 or other trim element) providing higher turndown - VFD connectivity for electrical savings on blowers or fans Reduced emissions - Fuel Air Control helps burner performance, optimal fuel/air control Better monitoring and connectivity - BACnet, Modbus and web services Remote troubleshooting - Web services or mobile using an IP address to monitor and troubleshoot from anywhere Broad application coverage - Industrial processes including burners, boilers and process heaters - Delivering enhanced safety

SLATE Solves Problems 15 Faster install, start-up and commissioning - All necessary boiler specific logic and functionality built it - Reduces install time Factory wired and tested - Ensures smooth start up and commissioning One supplier and one PO - One relationship to manage - Fewer SKUs to deal with Enhanced safety and code compliance - Meets latest codes and standards - NFPA85, ASME CSD-1, and CSA - SIL-3 capability; BMS-Flame Signal Processing, Limit, Fuel Air Ratio (early Q4 2016 Utilizes profiled version of Niagara AX - Function block programming

Gun Style Burners 16

Ovenpak Burner 17

Winnox Burner 18

BIO & BIC Burner 19

Duct Burners 20

AH-MA and NP Burner 21

22

Duct Box Burners 23

Thermal Solution 24 Burner Management System Exhaust Flue Emissions: NOx, SOx, CO Heat Recovery Heat Transfer Via: Direct Convection & Radiation OR Indirect Convection & Radiation Oxygen Source Air Oxy-Rich Air Pure Oxygen Fuel Train Oil Gas Burner Product 2015 by Honeywell International Inc. All rights reserved.