IECEx Certificate of Conformity

Similar documents
IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

slra IEC of Gonformity IECEx Cert f cate ü* t4

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

srra, of Conformity IECEx Gert f cate ?-ot,b

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Certificate of Compliance

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

FLASHLIGHT ANSI STANDARDS

INSTRUCTION & SERVICE MANUAL

Fixed Gas Detection System/Meridian CERTIFICATION

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

SPECIFICATION SHEET. Installation, Operation, Maintenance Instructions for safety use Series EX SOCKET SWITCH

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Operating Instructions

UL Electrical Equipment for Measurement, Control, and Laboratory Use; Part 1: General Requirements, Second Edition

INSTRUCTION MANUAL (ATEX / IECEx)

Earth-Rite II PLUS Static Earthing System

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

standards: standards:

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Manual Power relay SR853


Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Flameproof Manual Call Points Series MCP

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

FLASHLIGHT ANSI STANDARDS

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Certification Supplement Manual

Explosion-proof Immersion Heater Type D-8660

Certification Supplement Manual

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Certificate of Compliance

Electrical Installations Design, Selection, Erection and Inspection

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Integrated Solutions Low Voltage Systems

Certification Supplement Manual

Certificate of Compliance

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Rosemount 148 Temperature Transmitter. Quick Start Guide , Rev GA September 2016

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Survey of electrical equipment installed in hazardous areas on tankers

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Approvals, Certificates and Conditions

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

zonex enclosures hazardous locations

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

official distributor of Newson Gale Ltd.

Dräger Polytron 5720 IR Toxic Gas Detection

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

EXNBG CLARIFICATION/DECISION SHEETS NOTED BY THE ATEX STANDING COMMITTEE STATUS ON DECEMBER 2009

Switches compliant with ATEX directive

INSTRUCTION MANUAL (ATEX / IECEx)

Explosion Proof Manual Call Points Series MCP

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Dräger Polytron 5720 IR Detection of carbon dioxide

manual addendum DELPHI Ex

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx UL 08.0012X issue No.:5 Status: Current Date of Issue: 2015-02-25 Page 1 of 4 Applicant: Adalet/Scott Fetzer Co. 4801 W. 150th Street Cleveland, OH 44135 United States of America Certificate history: Issue No. 5 (2015-2-25) Issue No. 4 (2015-1-31) Issue No. 3 (2014-7-11) Issue No. 2 (2012-6-29) Issue No. 1 (2010-10- 15) Issue No. 0 (2009-6-12) Electrical Apparatus: Optional accessory: Terminal Enclosures Type of Protection: Increased Safety "e" and Dust "tb" Marking: Ex e IIC T6..T4 Gb for VC, VH, VCND and VHND series Ex tb IIIC T120 C Db IP66 for VC and VH series -50 C to +40 C for T6-50 C to +55 C for T5-50 C to +60 C for T4 Approved for issue on behalf of the IECEx Certification Body: Position: Paul T. Kelly Principal Engineer, Global Hazardous Locations Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: UL LLC 333 Pfingsten Road Northbrook IL 60062-2096 United States of America

Certificate No.: IECEx UL 08.0012X Date of Issue: 2015-02-25 Issue No.: 5 Page 2 of 4 Manufacturer: Adalet/Scott Fetzer Co. 4801 W. 150th Street Cleveland, OH 44135 United States of America Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-31 : 2008 Edition: 1 IEC 60079-7 : 2006-07 Edition: 4 Explosive atmospheres - Part 0: General requirements Explosive atmospheres Part 31: Equipment dust ignition protection by enclosure 't' Explosive atmospheres - Part 7: Equipment protection by increased safety "e" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: US/UL/ExTR08.0014/00 US/UL/ExTR08.0014/01 US/UL/ExTR08.0014/02 US/UL/ExTR08.0014/03 US/UL/ExTR08.0014/04 US/UL/ExTR08.0014/05 Quality Assessment Report: US/UL/QAR08.0003/05

Certificate No.: IECEx UL 08.0012X Date of Issue: 2015-02-25 Issue No.: 5 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: These devices are increased safety and dust protected terminal enclosures constructed out of brushed finish 316L stainless steel and are available in various sizes and depths. The enclosures consist of a cover, hinge assembly, body, external and internal grounding lugs, gland plates, gaskets and welded mounting lugs. The enclosure may be mounted in a vertical or horizontal position. See Annex for Nomenclature. CONDITIONS OF CERTIFICATION: YES as shown below: Please see Annex for Conditions of Certification.

Certificate No.: IECEx UL 08.0012X Date of Issue: 2015-02-25 Issue No.: 5 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Issue 1: Addition of model. Issue 2: Nomenclature was updated to increase the enclosure depth. New latch construction was evaluated. Issue 3: Updating to the latest standards and the addition of new terminal blocks. Issue 4: The addition of the VCND and VHND models. Issue 5: Updating DS589TB, DS869ND and DS869for the populated VC/VH enclosures to include new terminal block options.

Annex for IECEx UL 08.0012X Issue 5: Nomenclature: VC4X6 09 06 05 H A I II III IV V VI I. Basic Enclosure Designation VC4X Brushed Finish Stainless Steel 304 VC4X6 Brushed Finish Stainless Steel 316L VCND4- Cold Rolled/Hot Rolled Carbon Steel VCND4X Brushed Finish Stainless Steel 304 VCND4X6 Brushed Finish Stainless Steel 316L II. III. IV. Enclosure Length Enclosure Width Enclosure Depth XX Any two-digit number (16 maximum) V. Mounting Feet H Horizontal V - Vertical VI. Gland Plate Location A Gland Plate on Top Side B Gland Plate on Bottom Side C Gland Plate on Left Side D Gland Plate on Right Side VH4X6 0 10 08 A I II III IV V I. Basic Enclosure DesignationVH4X Brushed Finish Stainless Steel 304 VH4X6 Brushed Finish Stainless Steel 316L VHND4- Cold Rolled/Hot Rolled Carbon Steel VHND4X Brushed Finish Stainless Steel 304 VHND4X6 Brushed Finish Stainless Steel 316L II. III. Enclosure Length Enclosure Width

IV. Enclosure Depth XX Any two-digit number (16 maximum) V. Gland Plate Location A Gland Plate on Top Side B Gland Plate on Bottom Side C Gland Plate on Left Side D Gland Plate on Right Side The terminal blocks detailed in the table below were certified under their applicable IECEx certificates. Technical Differences were evaluated and found satisfactory- for detail see ExTR. MFG Model Certificate No. issue IEC 60079-0 rev IEC 60079-7 rev SAK/KrG 2.5/35 IECEx KEM 06.0014U * ZDU, ZDK, ZPE 05.0009U 1 2004 2001 SAKK IECEx SIR 05.0032U WDU,WDK,WPE 2.5-70 05.0008U WDU 2.5T/C IECEx SIR 05.0039U WFF IECEx KEM 07.0053U ZB w/o insulation IECEXULD13.0005U 0 2007 2006 ROCKWELL 1492-J ROCKWELL * 1492-L 06.0015U 06.0014U 1 2004 2001

Conditions of Use for Ex Equipment: This certificate applies to equipment without cable/conduit entries. When installing cable or conduit entries, the cable/conduit entries must be certified as increased safety, for protection type tb, and have a minimum IP66 rating for the VC and VH enclosures. When installing cable or conduit entries, the cable/conduit entries must be certified as increased safety have a minimum IP66 rating for the VCND and VHND enclosures. All unused conduit openings must be fitted with a certified close up plug equivalent of the apparatus and must be marked with an IP66 rating. The number of conductors entering the enclosure plus the number of internal connections (bridges and ground conductors are not counted) shall not exceed that of the Enclosure Size Terminal Content sheets. After installation, all creepage distances and clearances shall be according to Table 1 in IEC 60079-7,fourth edition. All conductors/cables shall be copper and shall be suitable for: 80 C when -50 C Ta +40 C, 95 C when -50 C Ta +55 C, 100 C when -50 C Ta +60 C. Each terminal block shall not be specified to accommodate more than one individual conductor in a clamping point unless specifically designed and assessed for doing so. For screwless connections intended for Class 5 or Class 6 fine stranded conductors according to IEC 60228, the fine stranded wire shall be equipped with a ferrule or the termination shall have a method to open the clamping mechanism so that the conductors are not damaged during installation of the conductor. The end user shall provide bonding means as necessary. See enclosure outline for conduit/cable layout information, minimum wire bending requirements, and minimum electrical clearance. To minimize the risk of electrostatic charge, provisions shall be made for adequate grounding and equipment shall be installed in such a manner so that accidental discharge shall not occur. When two wires are used, they shall be of the same type and size. All unused terminals shall be tightened.