OPERATING MANUAL UTY-RNNYM P/N English

Similar documents
HEAT & COOL MODEL (REVERSE CYCLE)

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

Compact Cassette Type

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

SU MO TU WE TH FR SA AM PM

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE

CASSETTE TYPE AIR CONDITIONER

AIR CONDITIONER Duct Type

CASSETTE TYPE

English AIR CONDITIONER OPERATING MANUAL. Compact Cassette Type Keep this manual for future reference P/N

English AIR CONDITIONER OPERATING MANUAL. Cassette Type Keep this manual for future reference. PART NO

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING MANUAL R410A FUJITSU GENERAL LIMITED REFRIGERANT. AIR CONDITIONER Compact Cassette Type HEAT & COOL MODEL (REVERSE CYCLE) P/N

HEAT & COOL MODEL (REVERSE CYCLE)

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

OPERATING M ANUAL CASSETTE TYPE FUJITSU GENERAL LIMITED OPERATING MANUAL AIR CONDITIONER. Indoor Unit AUU18RC AUU24RC AUU36RC AUU42RC

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

R410A ROOM AIR CONDITIONER WALL MOUNTED TYPE OPERATING MANUAL P/N REFRIGERANT KEEP THIS MANUAL FOR FUTURE REFERENCE.

MANUAL DE INSTRUÇÕES MANUAL DE FUNCIONAMIENTO OPERATING MANUAL

CONTENTS SAFETY PRECAUTIONS DANGER! CAUTION!

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use. Indoor unit 42TVU010, 012, Outdoor unit 38TVU010, 012, ENGLISH

AIR CONDITIONER OPERATING MANUAL. Cassette type. Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA. PART No

Before using this product, read these instructions thoroughly and keep this manual for future reference.

Operating Instructions

OWNER S MANUAL. AIR CONDITIONER (SPLIT TYPE) For general public use Indoor unit RAS-10, 13, 18, 24, 30BKS-HK

HEAT & COOL MODEL (REVERSE CYCLE)

FUJITSU GENERAL LIMITED AIR CONDITIONER FLOOR CONSOLE/ UNDER CEILING DUAL TYPE OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO P/N

Operating Instructions High-spec Wired Remote Controller

AIR CONDITIONER (SPLIT TYPE)

Operating Instructions High-spec Wired Remote Controller

AIR CONDITIONER Floor/Ceiling Type

MA Remote Controller PAR-31MAA

SPLIT TYPE AIR CONDITIONER INDOOR UNIT MODEL RAK-15QPB RAK-18RPB RAK-25RPB RAK-35RPB RAK-50RPB

CONTENTS SAFETY PRECAUTIONS. En-2 DANGER! WARNING! CAUTION! DANGER! CAUTION!

Compact Wall Mounted Type

MANUAL MODE D EMPLOI MW09Y3H MW12Y3H MR09Y3H MR12Y3H CONSERVEZ CE MODE D'EMPLOI POUR RÉFÉRENCE ULTÉRIEUR

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST24LBAJ AST30LBAJ. Outdoor Unit AOT24LMADL AOT30LMADL

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST18AB AST18RB AST24AB AST24RB AST30AB AST30RB

OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO

INDOOR UNIT/OUTDOOR UNIT

OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO

AIR CONDITIONER CEILING SUSPENSION TYPE

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST24PBA AST30PBA. Outdoor Unit AOT24PMAL AOT30PMAL

OPERATING MANUAL COOLING MODEL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST9ASJCW AST12ASJCW

OPERATING MANUAL R410A. Wall Mounted Type COOL MODEL FUJITSU GENERAL LIMITED REFRIGERANT AIR CONDITIONER. Indoor Unit ASTG24JF ASTG30JF ASTG34JF

OPERATING MANUAL FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER WALL MOUNTED TYPE. Indoor Unit AST20AG. Outdoor Unit AOT20AN P/N

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

MANUAL MODE D EMPLOI ASU9RL ASU12RL AOU9RL AOU12RL. English. Español Français CONSERVEZ CE MODE D'EMPLOI POUR RÉFÉRENCE ULTÉRIEUR

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

9 = Fig. 1. Fig. 2. Fig. 3. Fig. 5 % Fig. 4 $ Fig. 6 ) Fig. 8. Fig. 7 MED FAN DRY LOW QUIET CLOCK TIMER RESET AM SLEEP OFF ON AUTO AUTO

SERVICE MANUAL INDOOR UNIT. No. OBH788

ROOM AIR CONDITIONER WALL MOUNTED TYPE

OWNER S MANUAL AIR CONDITIONER (SPLIT TYPE) Indoor unit RAS-B10, 13, 16, 22N3KV2-E1. Outdoor unit RAS-10, 13N3AV2-E1 RAS-16, 22N3AV2-E ENGLISH

OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO

Operating Instructions

Owner's Manual TABLE OF CONTENTS

OPERATING MANUAL R410A HEAT & COOL MODEL (REVERSE CYCLE) FUJITSU GENERAL LIMITED REFRIGERANT ROOM AIR CONDITIONER WALL MOUNTED TYPE

Remote Controller. <Open the front cover> <ARC452A4>

OPERATING MANUAL R410A HEAT & COOL MODEL (REVERSE CYCLE) FUJITSU GENERAL LIMITED REFRIGERANT ROOM AIR CONDITIONER WALL MOUNTED TYPE

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXG20LV1BW FTXG25LV1BW FTXG35LV1BW FTXG50LV1BW FTXG20LV1BS FTXG25LV1BS FTXG35LV1BS FTXG50LV1BS

SERVICE MANUAL INDOOR UNIT

Mitsubishi ilmalämpöpumput huoltaa ja korjaa: Jäähdytinpalvelu RefGroup Oy

Owner s Manual AIR TO WATER HEAT PUMP. Hydro Unit HWS-804XWHM3-E HWS-804XWHT6-E HWS-804XWHT9-E HWS-1404XWHM3-E HWS-1404XWHT6-E HWS-1404XWHT9-E

WIRED REMOTE CONTROLLER

MANUAL DE FUNCIONAMIENTO OPERATING MANUAL MODE D EMPLOI WALL MOUNTED TYPE FUJITSU GENERAL LIMITED ROOM AIR CONDITIONER. Indoor Unit.

OPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1

OWNER S MANUAL VMH 09/12/18/24

ROOM AIR CONDITIONER WALL MOUNTED TYPE HEAT & COOL MODEL (REVERSE CYCLE) P/N KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE

Air Conditioner. User manual. Wired remote controller MWR-WE11N

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

FLOOR TYPE AIR CONDITIONER

SAT-3 Room Temperature Controller

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

Weekly Wired Remote Controller

SERVICE MANUAL MSZ-FH25VE MSZ-FH35VE INDOOR UNIT. No. OBH623. Models SPLIT-TYPE AIR CONDITIONERS

RAV-SM307KRTP-E RAV-SM407KRTP-E

OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO

En-2. Fig. 1 Indoor Unit 1 Operating Control Panel (Fig. 2) 2 AIR CLEANER RESET / MANUAL AUTO button

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

AIR CONDITIONER Compact Wall Mounted Type

OPERATING MANUAL R410A HEAT & COOL MODEL (REVERSE CYCLE) FUJITSU GENERAL LIMITED REFRIGERANT ROOM AIR CONDITIONER WALL MOUNTED TYPE

Owner s Manual TABLE OF CONTENTS

ENGLISH REMOTE CONTROL MANUAL

Operating Instructions Air Conditioner

SPLIT TYPE

Owner's Manual TABLE OF CONTENTS

DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXS20LVMA FTXS25LVMA FTXS35LVMA FTXS46LVMA FTKS20LVMA FTKS25LVMA FTKS35LVMA FTKS46LVMA

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Operation Manual - PC-ARF - P IMPORTANT:

Weekly Wired Remote Controller

Transcription:

OPERATING MANUAL English UTY-RNNYM P/N9373329206-04

OPERATING MANUAL CONTENTS SAFETY PRECAUTIONS... 1 NAME OF PARTS... 2 PREPARATORY OPERATION... 3 OPERATION... 4 TIMER FUNCTIONS... 6 ON/OFF TIMER... 6 WEEKLY TIMER... 7 P/N9373329206-04 TEMPERATURE SET BACK TIMER... 9 ADJUSTING THE DIRECTION OF AIR CIRCULATION...10 FILTER LAMP RESET...10 ERROR CODE DISPLAY...10 OPERATING TIPS...11 TROUBLESHOOTING... 12 SAFETY PRECAUTIONS Before using the appliance, read these SAFETY PRECAUTIONS thoroughly and operate in the correct way. The instructions in this section all relate to safety; be sure to maintain safe operating conditions. WARNING and CAUTION have the following meanings in these instructions: WARNING This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user. Do not attempt to install this controller by yourself. This controller contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the controller. If a problem (burning smell, etc.) occurs, turn off the electrical breaker immediately to stop operation, and then consult authorized service personnel. CAUTION This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user or damage to property. Do not expose the controller directly to water. Do not operate the controller with wet hands. Do not touch the switches with sharp objects. Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter. Check the condition of the installation stand for damage. Ensure that any electronic equipment is at least 1 m away from the controller. Avoid installing the controller near a fireplace or other heating apparatus. When installing the controller, take precautions to prevent access by infants. Do not use inflammable gases near the controller. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. En-1

NAME OF PARTS With cover open Display panel 1 2 3 4 5 6 7 15 8 9 10 11 12 13 14 Display panel 16 17 18 19 20 21 22 23 24 25 26 27 28 1 SET TEMP., SET TEMP. (Set Temperature Button) 2 TIMER MODE / CLOCK ADJUST (Timer Mode/Clock Adjust Button) 3 DAY / DAY OFF (Day/Day OFF Button) 4 SET BACK (Set Back Button) 5, (Set Time Button) 6 TIMER DELETE (Timer Delete Button) 7 TIMER SET (Timer Set Button) 8 START / STOP (Start/Stop Button) 9 MODE (Mode Button) 0 FAN (Fan Control Button) A (Horizontal airflow direction and swing Button) B (Vertical airflow direction and swing Button) C ECONOMY / THERMO SENSOR (Economy/Thermo Sensor Button) D MAINTENANCE / FILTER RESET (Maintenance/Filter Reset Button) E Operation Lamp F Day Display G Operation Lock Display H Temperature Display I Fan Speed Display J Timer Mode Display K Operation Mode Display L Timer and Clock Display M Filter Display N Economy Display O Thermo Sensor Display P Vertical Swing Display Q Horizontal Swing Display R Defrost Display Depending on the indoor unit model, some buttons on this remote controller cannot be used and some functions are restricted. Refer to the operation manual on the indoor unit. En-2

PREPARATORY OPERATION Set the current day and time 1 2 Press the DAY / DAY OFF button and select the current day. A appears around the selected day. Press the TIMER MODE / CLOCK ADJUST button for 2 seconds or more. The time display on the remote controller will fl ash. 3 Decrement Increment Press the button or button to set the current time. Press repeatedly to adjust the current time in 1-minute increments. Press and hold to adjust the current time in 10-minute increments. 4 SET BACK ex. Monday PM11:00 Press the SET BACK button to switch between the 12- and 24-hour time displays. 5 Press the TIMER MODE / CLOCK ADJUST button again to end. En-3

OPERATION Instructions relating to heating are applicable only to HEAT & COOL MODEL (Reverse Cycle). Preset values are displayed when the MODE button, the SET TEMP. button or SET TEMP. button, the FAN button is pressed while stopping. To start/stop operation Press the START / STOP button. Operation lamp Air conditioner ON: Lit brightly Air conditioner OFF: Not lit Blinking of START/STOP LED means occurrence of an error. Please refer to ERROR CODE DISPLAY in the manual. To set the operation mode Operation mode setting Press the MODE button to set the operation mode. If DRY is selected, the fan speed will be set to AUTO. AUTO COOL DRY FAN HEAT Room temperature setting Lower Rise Press the SET TEMP. button or SET TEMP. button to set the room temperature. Temperature setting range AUTO... 18 to 30 C COOL/DRY... 18 to 30 C HEAT... 16 to 30 C Fan speed setting Press the FAN button to select the fan speed. AUTO HIGH MED LOW QUIET ECONOMY OPERATION Economy setting Press the ECONOMY / THERMO SENSOR button to start or stop ECONOMY OPERATION. For details on the function, refer to page 11. En-4

OPERATION Room temperature sensor selection Indoor unit Press the ECONOMY / THERMO SENSOR button for more than 2 seconds to select whether the room temperature is detected at the indoor unit (remote sensor) or the remote controller. When the thermo sensor display appears, the room temperature is detected at the remote controller. NOTES This function is locked at the factory. If this function is locked, the location where the room temperature is detected cannot be changed and the mark flashes when the ECONOMY button is pushed for 2 seconds or more. In order to detect the room temperature correctly, consult authorized service personnel when using this function. Child lock function Press the DAY (DAY OFF) button and TIMER SET button simultaneously for 2 seconds or more to activate the child lock function and lock all buttons on the remote controller. Press the buttons again for 2 seconds or more to deactivate the child lock function. When the child lock function is activated, the mark appears. If any button is pressed during the child lock, the CL display and fl ash. En-5

TIMER FUNCTIONS OFF timer (See page 6.) Use this timer function to stop air conditioner operation. The timer operates and air conditioner operation stops after the set time has passed. The timer can be set up to 24 hours in advance. ON timer (See page 6.) Use this timer function to start air conditioner operation. The timer operates and air condition operation starts after the set time has passed. The timer can be set up to 24 hours in advance. WEEKLY timer (See page 7.) Use this timer function to set operating times for each day of the week. Use the DAY OFF setting to switch off timed operation for a selected day in the coming week. Because all days can be set together, the weekly timer can be used to repeat the timer settings for all of the days. Temperature SET BACK timer (See page 9.) Use this timer function to change the set temperature in the operation times set for each day of the week. This can be used together with other timer settings. ON/OFF TIMER To set the ON/OFF timer 1 No display NON STOP To cancel OFF TIMER Press the TIMER MODE / CLOCK ADJUST button to select the ON timer, OFF timer or weekly timer. It is switched every time as shown in the below diagram when the button is pressed. ON TIMER WEEKLY TIMER 2 Decrement From 1 to 24 hours Increment ex. OFF timer set for 6 hours Press the button or button to set the time. The timer starts automatically when an unoperated 3 seconds is passed after the timer setting is completed. The amount of time until the OFF timer operates that is displayed on the timer display decreases as time passes. The time can be changed by the Decrement/Increment buttons after the timer is once set. Press the TIMER DELETE button to cancel the timer mode. The timer mode can also be cancelled by changing the timer mode using the TIMER MODE / CLOCK ADJUST button. En-6

WEEKLY TIMER Weekly timer setting 1 2 3 Day of the week setting Press the TIMER MODE / CLOCK ADJUST button to select the weekly timer. Press the TIMER SET button for 2 seconds or more. ALL 1 2 Press the DAY / DAY OFF button to select the day of the week, and then press the TIMER SET button to confirm the setting. * When select ALL, all of the days will be selected. 36912 15 18 21 4 Time setting (ON / OFF timer) Decrement Increment When the operating time is set, the mark appears. 1 2 3 ON-1 OFF-1 ON-2 OFF-2 Press the button or button to set the ON time in 30-minute increments, then press the TIMER SET button to proceed to the OFF time setting. Set the OFF time in the same way. If necessary, set the second weekly timer settings in the same way. 5 6 ex. The timer is set for 7:00 A.M. 6:00 P.M. (7:00 18:00) To delete the operating time Repeat steps 3 and 4 to set the weekly timer for another day of the week. Press the TIMER SET button for 2 seconds or more to complete the weekly timer settings. If the TIMER DELETE button is pressed during steps 3 or 4, the operating time for the selected day will be deleted. If all the days are selected, the operating times for all of the days will be deleted. NOTES The operating time can be set in 30-minute increments only. The OFF time can be carried over to the next day. The ON timer and the OFF timer functions cannot be set using the weekly timer. Both an ON and OFF time must be set. En-7

WEEKLY TIMER WEEKLY timer operation To start To cancel Press the TIMER MODE / CLOCK AD- JUST button to start the timer mode. When the weekly timer is selected, the timer starts automatically. ex. Operating time 7:00 A.M. 6:00 P.M. (7:00 18:00) The operating time for the current day is displayed. Press the TIMER DELETE button to cancel the timer mode. The timer mode can also be cancelled by changing the timer mode using the TIMER MODE / CLOCK ADJUST button. To set the DAY OFF (for a holiday) 1 2 3 4 During the weekly timer, press the TIMER SET button for 2 seconds or more to set the day. Press DAY / DAY OFF and select a day to set the DAY OFF. Press the DAY / DAY OFF button for 2 seconds or more to set the DAY OFF. Press the TIMER SET button for 2 seconds or more to complete the DAY OFF setting. The mark flashes under a day of the week. ex. The DAY OFF is set for Monday. To cancel Follow the same procedures as those for setup. NOTES The DAY OFF setting is only available for days for which weekly settings already exist. If the operating time carries over to the next day (during a next day setting), the effective DAY OFF range will be set as shown below. Normal DAY OFF Next day setting DAY OFF ON OFF ON OFF ON OFF ON OFF WEEKLY WEEKLY WEEKLY WEEKLY Preceding day Setting day Next day Preceding day Setting day Next day The DAY OFF setting can only be set one time. The DAY OFF setting is cancelled automatically after the set day has passed. En-8

TEMPERATURE SET BACK TIMER Temperature SET BACK timer setting 1 SET BACK If there is no existing SET BACK temperature setting, - - will be displayed for the temperature. Press the SET BACK button to change to the SET BACK confi rmation display. The SET BACK operating time and the set temperature will be displayed. SET BACK timer automatically starts when an unoperated 5 seconds is passed, and then the display returns to the original indication. 3 Day setting Operating time setting Decrement Increment 2 Press the TIMER SET button for 2 seconds or more. It is switched to setting mode when the button is pressed within 5 seconds after the LCD of Step 1 is displayed. 1 2 3 4 ex. When setting all days together Follow steps 3 and 4 in To set the WEEKLY timer (Page 8). The TIMER DELETE button is also used as described in the procedures for the weekly timer. 4 Temperature setting Press the SET TEMP. button or SET TEMP. button to set the temperature (The temperature setting range is the same as the range for the operation mode.) 5 Lower Raise SET BACK temperature Normal temperature ON ex. Operating time 3:00 10:00 P.M. (15:00 22:00) 28 C OFF 24 C 24 C Repeat steps 3 and 4. Press the TIMER SET button for 2 seconds or more to complete the temperature SET BACK timer settings. Temperature SET BACK timer operation To start SET BACK To cancel 1 2 ex. Display during SET BACK timer operation (The operating time will not be displayed.) Press the SET BACK button. The SET BACK confi rmation display appears for 5 seconds, and then the timer starts automatically. Press the SET BACK button, and then press the TIMER DELETE button while the SET BACK confi rmation display is displayed. Even if the SET BACK button is pressed again, the SET BACK timer will be cancelled. En-9 NOTES The SET BACK timer only changes the set temperature, it cannot be used to start or stop air conditioner operation. The SET BACK timer can be set to operate up to 2 times per day but only one temperature setting can be used. The SET BACK timer can be used together with the ON, OFF, and weekly timer functions. The SET BACK operating time is displayed only in the SET BACK confi rmation display. (Refer to step 1 for the SET BACK confi rmation display.)

ADJUSTING THE DIRECTION OF AIR CIRCULATION Instructions relating to heating are applicable only to HEAT & COOL MODEL (Reverse Cycle). Start air conditioner operation before performing this procedure. To set the operation mode Vertical air direction adjustment (Swing operation) * Press the START/STOP button to start the air conditioner, and then proceed as follows. Press the button to adjust the direction of the vertical airfl ow. To set the swing operation, press the button for more than 2 seconds. (Stop the setting by pressing for more than 2 seconds again.) ex. Vertical swing operation Horizontal air direction adjustment (Swing operation) ex. Horizontal swing operation * Press the START/STOP button to start the air conditioner, and then proceed as follows. Press the button to adjust the direction of the horizontal airfl ow. To set the swing operation, press the button for more than 2 seconds. (Stop the setting by pressing for more than 2 seconds again.) Each time the button is pressed, the airflow direction setting changes as shown in MANUAL OPERATION which is included in IN- DOOR UNIT. NOTES When using the air conditioner in a room with infants, small children, or elderly or sick persons, the airfl ow direction and room temperature should be considered carefully when making the settings. The swing operation is not available depending on the model. Please refer to the MANUAL OPERATION for the INDOOR UNIT. FILTER LAMP RESET Some indoor unit models are equipped with a filter lamp in the indoor unit display to indicate when it is time to clean the air fi lters. Press the MAINTENANCE / FILTER RESET button for 2 seconds or more. The indoor unit fi lter lamp will go off and the fi lter display will disappear. As the factory setting, Filter Sign is not displayed. ERROR CODE DISPLAY This appears automatically on the display if an error occurs. If an error occurs, the following display will be shown. ( will appear in the set room temperature display.) If is displayed, immediately contact authorized service personnel. Stop air conditioner operation and please consult authorized service personnel. Faulty unit No. (0-15, C0) Ex. Error code display Error code En-10

OPERATING TIPS Instructions relating to heating are applicable only to HEAT & COOL MODEL (Reverse Cycle). To set the operation mode At the maximum output, ECONOMY OPERATION is approximately 70% of normal air conditioner operation for cooling and heating. (Single-type) At the maximum output, ECONOMY OPERATION (All indoor unit) is approximately 70% of normal air conditioner operation for cooling and heating. (Multi-type) During ECONOMY OPERATION, the thermostat setting automatically changes according to the temperature to avoid Unnecessary cooling and heating for the most economical operation. If the room is not cooled (or heated) well during economy operation, select normal operation. During the monitor period in the AUTO mode, the air conditioner operation will not change to ECONOMY OPERATION even if ECONOMY OPERATION is selected by pressing the ECONOMY button. Defrosting (for heating) When the outdoor temperature is low and the humidity high, frost will collect on the outdoor unit, reducing heater efficiency. When this happens, the computer will automatically start the defrost cycle. During the defrost cycle, the indoor fan will shutdown and will be displayed on the remote controller. It will take anywhere from 4 to 15 minutes before the air conditioner starts up again. Group Control One remote controller can control up to 16 air conditioners. All of the air conditioners will be operated with the same settings. Group control cannot be used when using it by the multi type. Dual Remote Controllers (optional) An additional remove controller can be added up to the maximum of 2 remote controllers. Either remote controller can control the air conditioner. However, the timer functions cannot be used at the slave unit. Simultaneous Use of Multiple Units Instructions relating to inverter ( ) are applicable only to INVERTER MODEL. Operation cannot be done in the following different operating modes. If the indoor unit is instructed to do an operating mode that it cannot perform, will be shown on the remote controller display and the unit will go into the standby mode. Heating mode and cooling mode (or dry mode) Heating mode and fan mode The operating mode (heating mode or cooling (dry) mode) of the outdoor unit will be determined by the operating mode of the indoor unit that was operated fi rst. If the indoor unit was started in fan mode, the operating mode of the outdoor unit will not be determined. For example, if indoor unit (A) was started in fan mode and then indoor unit (B) was then operated in heating mode, indoor unit (A) would temporarily start operation in fan mode but when indoor unit (B) started operating in heating mode, will be shown on the remote controller display and it would go into standby mode. Indoor unit (B) would continue to operate in heating mode. Oil Recovery (for heating) During the Oil recovery cycle, the indoor fan will shutdown and will be displayed on the remote controller. It will take Max. 5 minutes before the air conditioner starts up again. (Multi-type) En-11

TROUBLESHOOTING Instructions relating to heating are applicable only to HEAT & COOL MODEL (Reverse Cycle). WARNING In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker and consult authorized service personnel. Merely turning off the unit s power switch will not completely disconnect the unit from the power source. Always be sure to turn off the electrical breaker to ensure that power is completely off. Before requesting service, perform the following checks: Symptom Problem See Page NORMAL FUNCTION Airflow is stopped: During Heating operation, the unit will temporarily stop operation (between 4 and 15 minutes) as the Automatic Defrosting mode operates. During the Automatic Defrosting operation, will be shown on the remote controller display. 11 In case of Multi-type unit, during Heating operation, the unit will temporary stop operation (Max. 5 minutes) as the Automatic Oil Recovery mode operations. During the Automatic Oil Recovery operation, will be shown on the remote controller display. 11 In case of Multi-type unit, if multiple units are operated in different operation modes as shown below, the units operated afterward will stop and will be shown on the remote controller display of the stopped indoor units. Heating mode and cooling mode (or dry mode) Heating mode and fan mode 11 thermo sensor display on the remote controller is flashing: The room temperature sensor may be malfunctioning. Please consult authorized service personnel. If the problem persists after performing these checks, or if you notice burning smells, stop operation immediately, turn off the electrical breaker, and consult with authorized service personnel. En-12